Abstract
Contrast-enhanced CT is a primary tool in emergency departments for diagnosing acute aortic dissection, demonstrating high sensitivity and specificity. However, artifacts such as streak artifacts can mimic aortic dissection, leading to misdiagnosis. Here, we report a case involving a 21-year-old male who sustained traumatic injuries after a motor vehicle accident. Initial contrast-enhanced CT indicated a possible localized dissection in the descending aorta. Conservative treatment was initiated under the presumption of aortic dissection. Upon re-evaluation with ECG-gated CT, the previously identified "dissection" artifact had disappeared, revealing no actual aortic injury. This case illustrates how heartbeat-induced streak artifacts, while commonly seen in the aortic root, can also manifest in the descending aorta. Our findings underscore the importance of considering artifacts in atypical cases of aortic dissection, particularly when findings are localized to areas of the aorta in close proximity to the heart. For trauma patients, while dynamic contrast-enhanced CT remains standard, ECG-gated CT should be selectively applied where motion artifacts are suspected. This case highlights the role of advanced imaging options in distinguishing between true aortic pathology and artifacts, aiding in appropriate clinical decision-making.
Keywords: aortic dissection, cardiac pulsation artifacts, contrast-enhanced ct, diagnostic imaging, ecg-gated ct, motion artifacts, streak artifact, traumatic aortic injury
Introduction
Contrast-enhanced CT is frequently utilized in emergency departments for diagnosing acute aortic dissection due to its ease of application and ability to detect complications. The sensitivity and specificity of contrast-enhanced CT are reported to be between 98% and 100% [1]. Mimics of aortic dissection include ductal remnants, motion artifacts, infundibula, streak artifacts, and various technical factors [2]. This case report presents an instance of a streak artifact that was initially misdiagnosed as an aortic dissection, localized to the descending aorta.
Case presentation
A 21-year-old male with no prior medical history was injured when he collided with a car while riding a motorbike. The patient turned right at an intersection and was struck on the left side by a car approaching at 50 km/h. He was thrown approximately 5 meters but did not lose consciousness. Upon the arrival of emergency services, he reported pain in his left shoulder and hip. In the emergency department, his vital signs were stable: he was alert, with a respiratory rate of 20/min, blood pressure of 120/97 mmHg, pulse rate of 81/min, and oxygen saturation (SpO2) at 98% on room air. Physical examination revealed only minor contusions and abrasions on the face. Contrast-enhanced CT of the chest and abdomen, performed with the patient’s arms by his side, showed an apparent localized dissection in the descending aorta posterior to the heart, as well as a traumatic pulmonary contusion (Figure 1).
No other abnormalities were noted. The patient was admitted with a diagnosis of traumatic aortic dissection and initiated on conservative treatment with antihypertensive and analgesic medications. As the patient’s chest pain and vital signs remained stable, cardiac CT angiography was performed the following day (Figure 2).
This subsequent CT showed no signs of aortic dissection, and the pulmonary contusion remained unchanged. The patient was discharged the next day in stable condition.
Discussion
This case highlights the use of ECG-gated CT in clarifying a streak artifact in the descending aorta. Heartbeat-induced artifacts, typically seen as streak artifacts, usually appear in the aortic root but can occasionally extend to the descending aorta. Previous reports indicate that such streak artifacts arise from highly attenuated structures and cardiac pulsation, are often confined to one or two slices, extend beyond the aortic wall, and display a flap-like angle with variable appearance [3-5]. In this case, the artifact was present across five slices, differing from past reports, possibly due to the patient's young age, stable hemodynamics, and the improvements in imaging modalities since the 1980s and 1990s.
Dynamic contrast-enhanced CT is commonly used in emergency trauma settings [6]. However, ECG-gated CT, which is more effective in identifying motion artifacts, is recommended only in certain situations, as trauma patients frequently present with tachycardia and may struggle to hold their breath. Additionally, ECG-gated CT can compromise image quality of the lung parenchyma, ribs, and spine, suggesting that it should be selectively utilized based on the clinical scenario [7].
In the initial dynamic contrast-enhanced CT, findings appeared consistent with an aortic dissection, so further consideration of streak artifacts was overlooked. Reflecting on this case, it may have been possible to rule out the streak artifact based on the absence of intra-arterial flaps, pseudo-aneurysms, or extravasation of contrast medium, as well as the lack of adjacent hematoma near the aorta or mediastinum. Transesophageal echocardiography or MRI could have been considered for additional diagnostic clarity [8], though these were not pursued due to the availability of CT and the need for pulmonary contusion monitoring. Thus, the choice of additional diagnostic methods should be based on institutional resources and clinical objectives.
Conclusions
Traumatic aortic dissection requires prompt evaluation. Clinicians should be particularly vigilant for potential imaging artifacts, especially when abnormalities are localized in the descending aorta near the heart. These artifacts may appear over multiple imaging slices and could lead to diagnostic confusion.
Disclosures
Human subjects: Consent for treatment and open access publication was obtained or waived by all participants in this study.
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Takushi Santanda, Yuichi Nakamura, Joji Ito
Acquisition, analysis, or interpretation of data: Takushi Santanda
Drafting of the manuscript: Takushi Santanda
Critical review of the manuscript for important intellectual content: Takushi Santanda, Yuichi Nakamura, Joji Ito
References
- 1.Recommendations for accurate CT diagnosis of suspected acute aortic syndrome (AAS)--on behalf of the British Society of Cardiovascular Imaging (BSCI)/British Society of Cardiovascular CT (BSCCT) Vardhanabhuti V, Nicol E, Morgan-Hughes G, et al. Br J Radiol. 2016;89:20150705. doi: 10.1259/bjr.20150705. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Traumatic aortic injury: CT findings, mimics, and therapeutic options. Cullen EL, Lantz EJ, Johnson CM, Young PM. Cardiovasc Diagn Ther. 2014;4:238–244. doi: 10.3978/j.issn.2223-3652.2014.06.02. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography. Batra P, Bigoni B, Manning J, Aberle DR, Brown K, Hart E, Goldin J. Radiographics. 2000;20:309–320. doi: 10.1148/radiographics.20.2.g00mc04309. [DOI] [PubMed] [Google Scholar]
- 4.Problems and pitfalls in the evaluation of thoracic aortic dissection by computed tomography. Godwin JD, Breiman RS, Speckman JM. J Comput Assist Tomogr. 1982;6:750–756. doi: 10.1097/00004728-198208000-00015. [DOI] [PubMed] [Google Scholar]
- 5.Streak artefacts of the thoracic aorta: pseudodissection. Gallagher S, Dixon AK. J Comput Assist Tomogr. 1984;8:688–693. doi: 10.1097/00004728-198408000-00018. [DOI] [PubMed] [Google Scholar]
- 6.A pictorial review of acute aortic syndrome: discriminating and overlapping features as revealed by ECG-gated multidetector-row CT angiography. Ueda T, Chin A, Petrovitch I, Fleischmann D. Insights Imaging. 2012;3:561–571. doi: 10.1007/s13244-012-0195-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty. Schertler T, Glücker T, Wildermuth S, Jungius KP, Marincek B, Boehm T. Emerg Radiol. 2005;12:19–29. doi: 10.1007/s10140-005-0435-y. [DOI] [PubMed] [Google Scholar]
- 8.Incorrect diagnosis of type A aortic dissection attributed to motion artifact during computed tomographic angiography: a case report. Bennett JM, Sileshi B. A A Case Rep. 2017;9:254–257. doi: 10.1213/XAA.0000000000000582. [DOI] [PubMed] [Google Scholar]