Abstract
This report presents a patient with Legionella pneumonia (LP), initially presented with fever and mild hypoxemia, with subsequent progression to severe pneumonia during hospitalization. Despite multiple negative urinary antigen tests using Ribotest® Legionella, the diagnosis was confirmed via the loop-mediated isothermal amplification method of lower respiratory tract secretions. This case highlights the diagnostic limitations of Ribotest® Legionella and emphasizes the importance of a comprehensive diagnostic strategy, incorporating nucleic acid amplification tests or culture in suspected patients with LP. Early recognition of these diagnostic challenges is critical for optimizing patient outcomes.
Keywords: bronchoscopy, legionella pneumonia, loop-mediated isothermal amplification, ribotest® legionella, urinary antigen test
Introduction
Legionella pneumonia (LP) is a severe type of pneumonia primarily caused by Legionella pneumophila and is associated with increased morbidity and mortality. LP requires distinct antibiotic regimens compared to other forms of pneumonia caused by typical respiratory pathogens, and delays in initiating appropriate therapy can result in adverse patient outcomes [1]. Prompt recognition of Legionella infection is critical in the management of pneumonia, particularly in patients with severe illness or those at high risk.
The urinary antigen test (UAT) is a widely used initial diagnostic test for LP owing to its simplicity, rapid turnaround time, and relative cost-effectiveness [2-4]. However, conventional UATs are designed to detect lipopolysaccharide (LPS) in Legionella pneumophila serogroup 1 (SG1). L. pneumophila SG1 was the predominant causative pathogen of LP, accounting for 79.3% of cases, followed by non-SG1 L. pneumophila (11.4%), Legionella bozemanae (3.6%), Legionella dumoffii (3.6%), Legionella micdadei (1.4%), and Legionella longbeachae (0.7%) [5]. A systematic review of the diagnostic accuracy of conventional UATs for legionellosis reported an overall sensitivity of 0.79, improving to 0.86 when limited to L. pneumophila SG1 [3]. Consequently, a significant proportion of patients with LP remain undiagnosed with conventional UATs, highlighting the need for novel point-of-care tests (POCTs) that can detect a broader range of Legionella species and serogroups.
The Ribotest® Legionella (Asahi Kasei Pharma Corporation, Tokyo, Japan) is a newly developed UAT designed to detect all serotypes of L. pneumophila, aiming to overcome the limitations of conventional UATs [6,7]. However, its effectiveness in clinical practice remains insufficiently validated, with limited reports on diagnostic errors. Herein, we present a patient with LP diagnosed via loop-mediated isothermal amplification (LAMP) of lower respiratory tract secretions, despite multiple negative results of the Ribotest® Legionella.
Case presentation
A 55-year-old male presented to the emergency department with a two-day history of persistent fever, generalized fatigue, and shortness of breath. His medical history included hypertension, and he had no history of immunocompromised disorders. He was a current smoker with a 25 pack-year history. He had no recent travel history or exposure to hot springs, public baths, or soil contact. On admission, the patient was alert with a temperature of 40.9 °C, respiratory rate of 27 breaths/min, blood pressure of 159/79 mmHg, heart rate of 111 bpm, and oxygen saturation of 92% on ambient air.
The blood test results obtained at admission are shown in Table 1. Elevated white blood cell count (15,800/mm³) and CRP level (29.8 mg/dL) were observed. The albumin level was mildly reduced (3.3 g/dL), and the aspartate aminotransferase level was slightly elevated (40 IU/L). Additionally, hyponatremia (129 mmol/L) and hypokalemia (3.1 mmol/L) were noted. Arterial blood gas analysis was not performed. Chest radiography and CT revealed a wedge-shaped consolidation with an air bronchogram in the left lower lobe, along with scattered ground-glass opacities (GGOs) in the left upper lobe (Figure 1A, Figure 2A). Mild emphysema was also observed in both lungs. A polymerase chain reaction test for SARS-CoV-2 via pharyngeal swab was negative. Similarly, the UAT using Ribotest® Legionella provided a negative result. Blood and sputum samples were sent for culture.
Table 1. Laboratory test results on admission.
Parameter | Result | Normal range | |
WBC | 15.8 | ×103/mm3 | 4.0-9.0 |
Neutrophils | 93.5 | % | 40.0-60.0 |
Lymphocytes | 3.5 | % | 20.0-40.0 |
RBC | 4.3 | ×106/mm3 | 4.0-5.5 |
Hgb | 14 | g/dL | 13.0-17.0 |
PLT | 210 | ×103/mm3 | 150-350 |
TP | 6.5 | g/dL | 6.6-8.1 |
Alb | 3.3 | g/dL | 4.1-5.1 |
AST | 40 | IU/L | 13-30 |
ALT | 29 | IU/L | 10-42 |
LDH | 223 | IU/L | 135-225 |
CK | 96 | IU/L | 59-248 |
T-Bil | 0.6 | mg/dL | 0.2-1.2 |
BUN | 16.6 | mg/dL | 8.0-20.0 |
Cr | 0.91 | mg/dL | 0.65-1.07 |
Sodium | 129 | mmol/L | 138-146 |
Potassium | 3.1 | mmol/L | 3.6-4.9 |
Chloride | 91 | mmol/L | 99-109 |
CRP | 29.8 | mg/dL | 0-0.3 |
The clinical course of hospitalization is described in Figure 3. The patient was diagnosed with community-acquired pneumonia (CAP) and treated with intravenous ampicillin-sulbactam (12 g/day) and azithromycin (500 mg/day). Blood cultures were negative for any organisms. Sputum examination detected two types of gram-negative bacteria (Escherichia coli and Haemophilus influenzae) both susceptible to the initial antibiotic regimen. However, the patient’s high fever persisted, and his respiratory condition progressively worsened. In addition to persistent inflammation, laboratory tests revealed progressive hyponatremia and an elevated lactate dehydrogenase (LDH) level. Imaging studies revealed the progression of pulmonary infiltrates in both lungs (Figure 1, Figure 2).
Suspecting LP, azithromycin was replaced by intravenous levofloxacin (500 mg/day) on day 3 after admission. However, the patient’s respiratory condition did not improve. A second Ribotest® Legionella UAT, performed on day 4, was negative. On day 5, a bronchoscopic examination was performed under high-flow nasal oxygen therapy, revealing diffuse edematous changes in the lower airway mucosa, and orange secretions were collected for routine bacterial culture and Legionella testing, including LAMP assay and culture. Ampicillin-sulbactam was replaced by intravenous piperacillin-tazobactam (18 g/day), and levofloxacin was continued. The patient’s respiratory condition gradually improved, and he was discharged on day 16. Although culture tests from the bronchoscopy-obtained specimens were negative, the LAMP assay was positive, confirming a diagnosis of LP.
Discussion
This report presents a case of LP that could not be diagnosed through repeated UAT using Ribotest® Legionella. This case highlights two key points in the management of LP: (1) the novel UAT kit may fail to detect LP in patients with progressive respiratory failure even with serial testing, and (2) when epidemiological and/or clinical factors suggest LP, it is important to consider more sensitive diagnostic methods than UATs, such as nucleic acid amplification tests (NAATs) or culture.
Legionella are gram-negative bacilli commonly found in environmental water sources and are a frequent cause of severe CAP, with a mortality rate of 5-10% [1]. As Legionella replicates inside alveolar macrophages, it is resistant to β-lactam antibiotics, the mainstay of first-line treatment for CAP. However, it is susceptible to agents with high intracellular penetration, such as quinolones or macrolides [1]. Although available evidence is limited, bacterial coinfection is relatively common in patients with LP, particularly Streptococcus pneumoniae coinfection [8]. In the present case, the detection of E. coli and H. influenzae in the sputum culture test suggests the possibility of coinfection.
Delays in initiating antibiotics targeting Legionella may lead to worse patient outcomes [1]. Prompt diagnosis and timely treatment are essential in LP management. Ribotest® Legionella, developed in 2019, is a novel UAT kit that utilizes immunochromatography to detect L. pneumophila ribosomal protein L7/L12, in addition to conventional L. pneumophila SG1 LPS. This novel assay has demonstrated diagnostic accuracy comparable to that of conventional UATs and has the potential to detect non-L. pneumophila species and all L. pneumophila serotypes, making it a promising POCT for pneumonia management [6,7]. However, evidence on its diagnostic accuracy is limited, and further large-scale studies are needed to determine its effectiveness in clinical practice. In this case, Legionella infection was not detected using Ribotest® Legionella, despite repeated testing, and the final diagnosis was made using the LAMP method on bronchoscopy-obtained lower respiratory tract samples.
Several factors could explain the multiple negative UAT results. First, the early stage of infection and relatively low disease severity at the time of testing. After the onset of LP, urinary antigen levels increase as the bacterial load in the lungs increases over time [9-11]. Therefore, repeated testing can be helpful when the initial UAT result is negative. Notably, urinary antigen levels may increase to a detectable level approximately three days after symptom onset [9,10]. Motokura et al. reported a patient with LP caused by L. pneumophila SG1, where the second Ribotest® Legionella UAT had successfully diagnosed the infection four days after an initial failure of diagnosis upon admission [11]. Additionally, UAT sensitivity was directly correlated with the severity of LP, with higher sensitivity in more severe cases [12]. In the present case, despite four days since the onset and the progression of respiratory failure, the second UAT failed to detect Legionella infection. Second, a previous study suggested that antigens are released into urine intermittently in some cases of LP [4], which may explain the negative UAT results. Third, the infection may have been caused by a Legionella species other than L. pneumophila, accounting for approximately 9.3% of LP in Japan [5]. Considering the repeated UAT failures, we believe that this is the most likely explanation for false negative results with Ribotest® Legionella. Oda et al. reported a case of L. longbeachae pneumonia that Ribotest® Legionella failed to diagnose [13]. Similarly, Shinomiya et al. described a case of L. longbeachae pneumonia, where the first UAT was negative, but the second test identified the infection [14]. A high antigen load is required to detect non-L. pneumophila species using the Ribotest® Legionella, leading to lower sensitivity compared to detecting L. pneumophila [6,14].
Our case highlights the importance of advanced diagnostic tests, including NAAT and culture, and emphasizes the need for physicians to incorporate these tests to improve diagnostic accuracy even when Ribotest® Legionella is available. While advanced tests, including the LAMP, are more sensitive than the UAT and capable of detecting all Legionella species, they are more expensive and difficult to perform in many facilities [4,15]. Therefore, it is appropriate to reserve these tests for patients with a high suspicion of LP and negative UAT results. Recent international guideline for CAP recommends Legionella UAT, and/or additional tests, for patients with known epidemiological risk factors and/or severe pneumonia [2]. However, these risk factors are insufficient to predict LP, as most cases are sporadic [16], and patients may initially present with mild symptoms, even if they later require admission to the intensive care unit [17]. In this case, the patient had no history of travel or exposure to a local Legionella outbreak and presented with mild hypoxemia on admission. A more practical approach to predicting LP would involve the patient’s symptoms, vital signs, and diagnostic workup. For example, a diagnostic score consisting of six clinical and laboratory parameters (i.e., high fever, high CRP, high LDH, thrombocytopenia, hyponatremia, and unproductive cough) has demonstrated good diagnostic reliability in several studies [18]. Additionally, multi-lobar or multi-segmental lung consolidations with GGOs were well-documented CT features of LP [19]. Furthermore, orange-colored lower respiratory tract secretions may be a characteristic feature of LP [20]. These findings allowed us to pursue the diagnosis of LP, despite repeated negative UAT results and the detection of the other pathogens in the sputum specimens.
Conclusions
Ribotest® Legionella UAT kit may fail to diagnose LP, even with repeated testing. Physicians should recognize this limitation and carefully assess the possibility of Legionella infection in the management of pneumonia. In patients with high clinical suspicion of LP, it is crucial to follow a multimodal approach, including NAAT or cultures. Additionally, negative UAT results should not rule out LP. The development and implementation of rapid and highly sensitive diagnostic tools across various healthcare settings are needed to further improve patient outcomes.
Disclosures
Human subjects: Consent for treatment and open access publication was obtained or waived by all participants in this study.
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Yasushi Murakami, Mika Morosawa, Yasuhiro Nozaki, Yoshio Takesue
Drafting of the manuscript: Yasushi Murakami, Yoshio Takesue
Critical review of the manuscript for important intellectual content: Yasushi Murakami, Mika Morosawa, Yasuhiro Nozaki, Yoshio Takesue
Supervision: Yoshio Takesue
References
- 1.Severe Legionnaires' disease. Rello J, Allam C, Ruiz-Spinelli A, Jarraud S. Ann Intensive Care. 2024;14:51. doi: 10.1186/s13613-024-01252-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Diagnosis and treatment of adults with community-acquired pneumonia. An Official Clinical Practice Guideline of the American Thoracic Society and Infectious Diseases Society of America. Metlay JP, Waterer GW, Long AC, et al. Am J Respir Crit Care Med. 2019;200:0–67. doi: 10.1164/rccm.201908-1581ST. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Diagnostic accuracy of urinary antigen tests for legionellosis: a systematic review and meta-analysis. Kawasaki T, Nakagawa N, Murata M, et al. Respir Investig. 2022;60:205–214. doi: 10.1016/j.resinv.2021.11.011. [DOI] [PubMed] [Google Scholar]
- 4.Clinical and laboratory diagnosis of Legionella pneumonia. Bai L, Yang W, Li Y. Diagnostics (Basel) 2023;13:280. doi: 10.3390/diagnostics13020280. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Distribution of Legionella species and serogroups in patients with culture-confirmed Legionella pneumonia. Miyashita N, Higa F, Aoki Y, et al. J Infect Chemother. 2020;26:411–417. doi: 10.1016/j.jiac.2019.12.016. [DOI] [PubMed] [Google Scholar]
- 6.Evaluation of five Legionella urinary antigen detection kits including new Ribotest Legionella for simultaneous detection of ribosomal protein L7/L12. Nakamura A, Fukuda S, Kusuki M, et al. J Infect Chemother. 2021;27:1533–1535. doi: 10.1016/j.jiac.2021.05.019. [DOI] [PubMed] [Google Scholar]
- 7.Evaluation of a novel urinary antigen test kit for diagnosing Legionella pneumonia. Ito A, Yamamoto Y, Ishii Y, et al. Int J Infect Dis. 2021;103:42–47. doi: 10.1016/j.ijid.2020.10.106. [DOI] [PubMed] [Google Scholar]
- 8.Comparison of sputum microbiome of legionellosis-associated patients and other pneumonia patients: indications for polybacterial infections. Mizrahi H, Peretz A, Lesnik R, et al. Sci Rep. 2017;7:40114. doi: 10.1038/srep40114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Onset and duration of urinary antigen excretion in Legionnaires disease. Kohler RB, Winn WC Jr, Wheat LJ. J Clin Microbiol. 1984;20:605–607. doi: 10.1128/jcm.20.4.605-607.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Sequential changes of Legionella antigens and bacterial load in the lungs and urines of a mouse model of pneumonia. Chen Y, Tateda K, Fujita K, et al. Diagn Microbiol Infect Dis. 2010;66:253–260. doi: 10.1016/j.diagmicrobio.2009.11.001. [DOI] [PubMed] [Google Scholar]
- 11.Severe Legionella pneumonia in which serial testing by Ribotest® Legionella was useful for the diagnosis. Motokura Y, Ito A, Ishida T. Intern Med. 2023;62:2989–2993. doi: 10.2169/internalmedicine.0766-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Sensitivity of urinary antigen test in relation to clinical severity in a large outbreak of Legionella pneumonia in Spain. Blázquez RM, Espinosa FJ, Martínez-Toldos CM, Alemany L, García-Orenes MC, Segovia M. Eur J Clin Microbiol Infect Dis. 2005;24:488–491. doi: 10.1007/s10096-005-1361-3. [DOI] [PubMed] [Google Scholar]
- 13.Legionella longbeachae pneumonia: a case report and literature review in Japan. Oda N, Taki T, Mitani R, Takata I. J Infect Chemother. 2021;27:751–754. doi: 10.1016/j.jiac.2020.12.010. [DOI] [PubMed] [Google Scholar]
- 14.A case of severe pneumonia caused by Legionella longbeachae with positive results by a Legionella urinary antigen detection kit. Shinomiya S, Tanaka T, Shionoya I, et al. Ther Adv Infect Dis. 2023;10:20499361231179863. doi: 10.1177/20499361231179863. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.National survey of physicians in Japan regarding their use of diagnostic tests for legionellosis. Kinjo T, Ito A, Ishii M, et al. J Infect Chemother. 2022;28:129–134. doi: 10.1016/j.jiac.2021.12.008. [DOI] [PubMed] [Google Scholar]
- 16.Legionellosis on the rise: a scoping review of sporadic, community-acquired incidence in the United States. Moffa MA, Rock C, Galiatsatos P, Gamage SD, Schwab KJ, Exum NG. Epidemiol Infect. 2023;151:0. doi: 10.1017/S0950268823001206. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Incidence and risk factors associated with progression to severe pneumonia among adults with non-severe Legionella pneumonia. Huh JY, Choi SH, Jo KW, et al. Acute Crit Care. 2022;37:543–549. doi: 10.4266/acc.2022.00521. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Clinical presentation of Legionella pneumonia: evaluation of clinical scoring systems and therapeutic efficacy. Miyashita N, Higa F, Aoki Y, et al. J Infect Chemother. 2017;23:727–732. doi: 10.1016/j.jiac.2017.09.001. [DOI] [PubMed] [Google Scholar]
- 19.Thoracic imaging features of Legionnaire's disease. Mittal S, Singh AP, Gold M, Leung AN, Haramati LB, Katz DS. Infect Dis Clin North Am. 2017;31:43–54. doi: 10.1016/j.idc.2016.10.004. [DOI] [PubMed] [Google Scholar]
- 20.Sputum colour: an indicator of Legionella pneumophila pneumonia. Sumi T, Suzuki K, Koshino Y, Ikeda T, Yamada Y, Chiba H. Respirol Case Rep. 2024;12:0. doi: 10.1002/rcr2.1312. [DOI] [PMC free article] [PubMed] [Google Scholar]