Abstract
We introduce two water-soluble excited state intramolecular proton transfer (ESIPT) based fluorescent turn-on probes responding to inorganic polyphosphates. These ESIPT probes enable specific detection of short-chain inorganic polyphosphates over a range of different condensed phosphates. The probes are weakly emissive in their off-state due to the blocking of ESIPT by Cu2+ coordination. Removal of the copper ion through decomplexation by the analyte accesses the on-state. The probes detect polyphosphates over other biologically occurring phosphates, pyrophosphate, and nucleotides such as ATP, ADP, GTP. An optimal fluorescence response is observed with the short-chain polyphosphate polyP8. Furthermore, the probe shows selectivity towards linear polyphosphates over cyclic metaphosphates. The rapid ‘turn-off–turn-on’ fluorescence responses upon consecutive addition of Cu2+ and polyP8 are reversible, further highlighting sensor performance in an aqueous environment. One of the sensors is then used to monitor polyP digestion by an exopolyphosphatase (PPX).
We introduce two water-soluble excited state intramolecular proton transfer (ESIPT) based fluorescent turn-on probes responding to inorganic polyphosphates.
Introduction
Inorganic polyphosphate (polyP), an ancient macromolecule also considered to be a ‘molecular fossil’, has been detected in all living organisms.1 The linear anionic polymer consists of three to several thousands of units of orthophosphate (Pi) monomers, interconnected by high-energy phosphoanhydride bonds.2 PolyP plays diverse roles in both prokaryotic and eukaryotic cells.3 For example, it is involved in energy storage,4 molecular chaperoning, regulating apoptosis,5 hemostatis and thrombosis,6 bone mineralization and proinflammatory functions,7 and oxidative stress response.8 Moreover, polyP has been linked to cognitive performance as well as neurodegenerative conditions such as Parkinson's disease, Alzheimer's disease, and amyotrophic lateral sclerosis.9 Short-chain polyPs are found in parasites such as Trypanosoma cruzi, Trypanosoma brucei, and Leishmania major where they are important for parasite metabolism.10 Besides its biological roles, polyP is also important in biotechnological applications such as ATP regeneration systems using polyP kinases.11 Furthermore, the ability of microorganisms to accumulate polyP is used to remove phosphates from wastewater.12
Given the diverse areas in which polyP plays an important role, there is a significant demand for simple chemical sensors that enable the detection of polyP, ideally with selectivity regarding chain length. For biological applications, such detection would benefit from selectivity over other abundant condensed phosphates, such as e.g. ATP. Currently, there is only a very limited number of colorimetric and fluorescent probes available to visualise polyPs. The use of 4′,6-diamidino-2-phenylindole (DAPI), a yellow fluorescent compound in complex with polyP, is the most popular approach, owing to its significant fluorescence shift when binding to polyP.13 In addition to DAPI, toluidine blue has also been used for the detection of polyPs. However, literature reports that only polyPs with a chain length longer than 15 units are detected by DAPI and toluidine blue.1d,14 Also, some interferences with other phosphate containing molecules have been reported. For example, characteristic yellow fluorescence is also emitted from DAPI-inositol phosphate complexes.15 As an alternative to DAPI-polyP emission, Pavlov's group reported fluorescent benzimidazolinium dyes, but these also require longer chain polyPs.16 Thus, currently the detection of polyPs with fluorescent sensors is not covering polyPs with comparatively short-chains in the single digit range.
Selective fluorescent sensors of important (condensed) phosphates, such as Pi and pyrophosphate (PPi), have been developed using different strategies, including hydrogen bonding interaction, coordination chemistry, displacement assay/decomplexation, and aggregation-induced emission/quenching.17 Over the past few decades, the design of fluorogenic sensors based on Excited-State Intramolecular Proton Transfer (ESIPT) has gained considerable attention due to their useful emissive properties including very large Stokes shifts (∼200 nm). Moreover, such sensors often combine ultra-fast rates with little reabsorption.18a In the ESIPT process, fluorophore tautomers in the ground state and excited states of enol- (E and E*) and keto-forms (K and K*) generate four photochemical states (Scheme 1a). Because of its unique ‘turn-off–turn-on’ photoisomerization feature and low background interference, an ESIPT-active molecule provides sensing opportunities in diverse applications. ESIPT based sensors have been used for the detection of a variety of anions, most notably in the context of this study: PPi.18
The choice of using an ESIPT-based strategy is promising due to its current success in detection of numerous environmentally and biologically significant analytes.18a,19 However, achieving selective detection of polyP over PPi and other anions like nucleotides is not a trivial task. Moreover, the sensor should rapidly respond in an aqueous environment. This adds a solubility problem, as a majority of the known ESIPT based fluorescence sensors are only sparingly soluble in aqueous solution, which limits their widespread applicability.20 Herein, we report the first chemoselective, reversible, water-soluble, short chain inorganic polyP sensors that work in an aqueous environment and rely on the ESIPT mechanism providing large Stokes shifts for diverse applications.
Results and discussion
Ligand design and synthesis
The ESIPT phenomenon is linked to the presence of an intramolecular hydrogen bond, usually between a proton donor (–OH/–NH) and a proton acceptor (–C O/heterocyclic N). The fluorophore 2-hydroxy phenyl benzoxazole and its derivatives could provide on–off switching properties of the ESIPT signal through metal complexation, leading to metal induced fluorescence quenching. Decomplexation of the metal through the analyte would then lead to recovery of the ESIPT signal. Provided the decomplexation can be selective, as previously shown in disassembly strategies, e.g. by the Zelder group for PPi,21 one could design a polyphosphate responsive ESIPT sensor. To confer solubility in aqueous medium, a charged group, such as a sulfonate, would be beneficial. Based on the above considerations, fluorophore 4 was synthesized in four steps starting from 3-chloro-2-hydroxybenzaldehyde (Scheme 2). Condensation of aniline with 3-chloro-2-hydroxybenzaldehyde afforded imine 1.22 The imine intermediate 1 was refluxed with conc. H2SO4 to introduce a sulfonate group at the 5 position in 84% yield. Treatment with Na2CO3 gave the sodium salt 3 in 58% yield. Afterwards, condensation of 3 with 2-aminophenol followed by in situ cyclization afforded the ESIPT fluorophore 4 in 41% yield (Scheme 2). Another ESIPT fluorophore 5 was synthesized in two steps in 52% yield (Scheme 2). These two fluorophores with slightly modulated photophysical properties served as basis for our follow-up studies.
The main challenge for designing fluorescence sensors for negatively charged species is that its hydration tendency reduces the sensors’ ability to interact with the target analyte.23 One potential solution to surmount this challenge involves the employment of a displacement strategy where initially the fluorescent probe is complexed to a metal ion that quenches the fluorescence (metal-ion induced fluorescence quenching).24 Then, decomplexation of the metal ion by the negatively charged analyte leads to a restored ESIPT fluorophore. Copper complexes have been used for Pi and PPi sensing,25 however no other condensed phosphate chains have been examined with related complexes.
To generate a metal quenched ESIPT-OFF probe 6, we reacted probe 4 with 0.5 equiv. of CuCl2 at room temperature (61% yield). The formation of this complex in a 2 : 1 stoichiometry was confirmed by HRMS data (Fig. S7†). Furthermore, we confirmed the correct stoichiometry by changes in photophysical properties and Job's plot analysis (see next section). While the Cl substituent in 6 was mainly installed to enable further potential modifications, we also generated a non-chlorinated version to study and compare the impact of substitution on the photophysical properties and selectivity regarding different anions. An identical complexation of 5 with Cu2+ in a 2 : 1 stoichiometry was conducted, resulting in complex 7.
Photophysical studies of the fluorophores in the presence of Cu2+
Spectrophotometric titration was used to examine the UV-Vis absorption spectrum of ligand 4 in 10 mM HEPES buffer solution at pH 7.4 (Fig. 1a). A prominent band with an absorption peak at 368 nm was visible. With increasing addition of Cu2+ (from 0.1–0.5 equiv.) the absorption maximum at 368 nm increased, and adding more equivalents did not elicit additional changes indicating a 2 : 1 complexation with Cu2+.
The fluorescence spectra of ligand 4 in an aqueous solution (10 mM HEPES buffer, pH = 7.4) are shown in Fig. 1b (see ESI Fig. S2 and S3† for 5) along with their changing intensities upon addition of Cu2+ ion in the solution. While excited at 254 nm, 4 exhibited a strong emission band centred at 434 nm in the buffer solution with a large Stokes shift of 180 nm, typical for an ESIPT fluorophore. Upon addition of different equivalents of Cu2+ (0 to 1 equivalent) into the solution of 4, the fluorescence intensity gradually decreased and a quench in fluorescence was observed at ca. 0.5 equivalents (Fig. 1c). The fluorescence intensity decreased linearly until 0.5 equivalents Cu2+, at which point it reached a plateau. Increasing from 0.5 to 1 equivalent of Cu2+ did not lead to further changes, suggesting that 4 is complexed with Cu2+ in a 2 : 1 stoichiometric ratio. Further, the 2 : 1 stoichiometry was confirmed by a Job's plot (Fig. 1d) and the HRMS data for 6 and 7 (Fig. S7 and S8, respectively†).
Next, we investigated the decomplexation of Cu2+ from the probes 6 and 7 with different condensed phosphates, which would release the ESIPT fluorophore. Long polyphosphates are obtained as polydisperse mixtures of varying chain length, rendering analytics more difficult. Initially, we therefore looked into the decomplexation of the sensor with polyP8, which is currently the longest monodisperse polyP available by synthesis. Also shorter polyphosphates are accessible in monodisperse form through chemical synthesis (see ESI section 12†).26 Addition of polyP8 to complex 6 (in 10 mM HEPES buffer at pH = 7.4) led to a gradual decrease of the absorption peaks at 288 nm, 300 nm and 356 nm (Fig. 2a). In case of complex 7, the absorption peaks at 254 nm, 284 nm and 351 nm also decreased while absorption increased at 317 nm with increasing polyP8 concentration (Fig. 2b). Interestingly, the decrease in absorption intensities was much higher with non-chlorinated 7 compared to chlorinated 6. The structures of complexes 6 and 7 are tentatively assigned to be square planar, but we could not obtain crystal structures of the compounds. The very different behaviour might be a result of distortions of the geometry based on steric constraints potentially exerted by the chlorine atom.
Both complexes were further studied regarding their ESIPT-ON state upon titration. PolyP8 sensing of weakly emissive 6 was investigated by using fluorescence spectroscopy. Upon addition of polyP8 sodium salt into a solution of 6 (2.5 μM in 10 mM HEPES buffer at pH = 7.4), the fluorescence emission intensity (λex = 254 nm) centred at λem = 434 nm was progressively enhanced within 2 minutes of polyP8 addition. An eightfold enhancement in the fluorescence intensity was observed when 10 equiv. of polyP8 were added (Fig. 3a). We attribute these significant changes in the spectral properties to the removal of Cu2+ from the ligand's coordination sphere by polyP8, releasing the ESIPT fluorophore characterized by its large Stokes shift.
During excitation at 254 nm, we observed a polyP8 concentration-dependent fluorescence increase at 434 nm (Fig. 3b). The titration resulted in a sigmoidal curve, by using nonlinear regression analysis of the polyP8 induced emission data. Notably, the fluorescence intensity did not decrease with time (Fig. S5†), demonstrating stability of the released fluorophore. To determine the complexation stoichiometry between 6 and polyP8, Job's plot analysis was conducted on the basis of the emission intensity at 434 nm (Fig. 3c). The result suggested that a 1 : 2 stoichiometry was found between 6 and polyP8, while [6] + [polyP8] = 5 μM was maintained throughout the experiment.24 Probe 7 (5 μM concentration) behaved in a similar way and showed ESIPT-ON under titration with polyP8 (excitation at 250 nm, emission at 430 nm; see Fig. S4†).
Selectivity studies of the probes over other phosphates
Given the excellent ESIPT-ON properties of the sensors in response to polyP8, we were now interested in profiling the selectivity of 6 and 7 with respect to other condensed phosphates. Both probes 6 and 7 were incubated with a wide range of biologically relevant (condensed) phosphates, like monophosphate (Pi), pyrophosphate (PPi), several abundant nucleotides such as ATP, AMP, ADP, GTP, GMP and GDP under the same conditions of 10 mM HEPES at pH = 7.4 with 2 minutes of incubation time. The emission intensities elicited by all these analytes were measured. Fig. 4a shows that the decomplexation and resulting ESIPT fluorescence of 6 reached a maximum in presence of polyP8 as compared to other tested anions. Both sensors 6 and 7 had a similar selectivity profile regarding anions. However, the emission intensity was higher for the released ESIPT fluorophore 4, enabling its application at twofold lower concentrations. Quantum yields for 4 and 5 were determined to be 0.33 and 0.16 respectively (Experimental details in the ESI†), directly explaining the higher sensitivity of 6 in the assays. Such values are comparably high for ESIPT fluorophores and must be an effect of the sulfonate group we introduced. The limit of detection (LOD) of polyP8 with 6 and 7 were found to be 97 nM and 110 nM, respectively (details in ESI Section 9†).27
Both sensors did not respond to phosphate (Pi) and monophosphate esters, such as GMP or AMP. In contrast, both sensors did respond to pyrophosphate (PPi), but the increment in fluorescence gain is small in both cases. Diphosphate esters like e.g. ADP and GDP also elicited a response, but reduced when compared to free PPi. Nucleoside triphosphates like ATP or GTP also released some of the fluorophore, but by far the largest increment of ca. 8-fold was achieved with polyP8 in both cases. Consequently, sensors 6 and 7 represent the first selective short-chain polyP sensors that work in an aqueous environment based on an ESIPT-ON mechanism (Fig. 4a and b).
Next, we investigated the dependence of the signal of sensors 6 and 7 on polyP chain lengths using several synthetic standards and commercial polydisperse references. Interestingly, we observed that with increasing chain length the signal intensity increased, reaching a plateau around polyP8,28 when incubated under the same conditions (10 mM HEPES, pH = 7.4). Fig. 5 depicts this trend in fluorescence intensity gain from monophosphate to pyrophosphate to polyP8 (10 equivalents of each different polyP with 6 or 7). We also examined the fluorescence response of probes 6 and 7 towards different cyclic metaphosphates like cyP3, cyP4 and cyP8.29 cyP4 and cyP8 showed a considerable fluorescence response, unlike cyP3. Yet, linear polyP8 still elicited a 1.5 times higher response as compared to its cyclic analogue cyP8 (Fig. 5a and c).
We also profiled longer polyphosphate chains, which are commercially available. These are polydisperse mixtures of different chain length and so it is difficult to obtain their real concentration. Usually, the phosphate content in thus indicated in terms of Pi monomers after digestion with exopolyphosphatase (PPX).1d After increasing the concentration of the longer chain polyPs (polyP14–polyP700) to 125 μM for 6 and 250 μM for 7 (in terms of Pi residues), we observed a trend of reduced response from both sensors 6 and 7 with increasing chain length from polyP14 (7-fold increase) to polyP130 and polyP700 (4-fold increase), indicating that our sensors are most responsive to short-chain polyP with an average chain length of around 8 (Fig. 5b and d).
Probe 6 is an efficient reversible fluorescent sensor
In order to assess the reversibility of probe 6, we investigated its fluorescence emission in response to alternating pulses of polyP8 and CuCl2. Addition of Cu2+ into a solution of 4 leads to a quench of fluorescence at 434 nm due to the formation of 6. The fluorescence was recovered by the addition of polyP8 into the solution of 6, leading to the release of 4. Five alternating additions of Cu2+ and polyP8 showed interconversion of 4 to 6 and back, which indicates that 4 can be used as a reversible fluorescent ‘turn-off–turn-on’ probe for Cu2+ and polyP8 (Fig. 6b). The concentration of Cu2+ and polyP8 had to be adjusted in each cycle to obtain reversibility (see details in ESI Section 4†).
Detection of polyP digestion by probe 6
Next, we investigated, if ESIPT sensors would enable us to follow polyP digestion by the enzyme exopolyphosphatase (PPX) in vitro. PPX assays are widely applied in polyP research. PPX digests long-chain polyphosphate releasing Pi units and one equivalent of PPi per chain.1d Thus, the digestion of polyP chains can potentially be monitored using the sensors 6 or 7, as Pi and PPi only elicited no or only a little response by releasing 4 or 5, respectively (Fig. 4). Using this rationale, we investigated the application of the more sensitive probe 6, due to its higher response, towards monitoring polyP digestion by PPX. PPX (2.9 mg mL−1, 40 mM Tris-acetate, 10 mM Mg(OAc)2, 30 mM NH4OAc, 0.2 mM EDTA at pH = 8) was added to an aqueous solution of polyphosphates of varying chain length (2–10 mM, for polydisperse polyphosphates the concentration is based on Pi units) and incubated at 37 °C for 21 h. The enzyme reaction mixture as well as the control (no PPX) were added separately to a solution of 2.5 μM of 6 (in 10 mM HEPES buffer at pH = 7.4), and the ensuing fluorescence intensity at 434 nm was measured as the mean of three replicates in a 96 well-plate (details in ESI Section 5†). When the control mixture (only polyP8, no PPX) was incubated with probe 6, a clear increase in emission was observed. However, no significant increase in the emission intensity was observed when incubated with the PPX reaction mixture, because of the digestion of polyP8 by PPX to 6 Pi units and one PPi (Fig. 7a and b).
PolyP digestion was also monitored for polydisperse polyphosphates (polyP22, polyP60, and polyP130). A significant decrease in fluorescence emission after digestion was observed (Fig. 7c–e). It is apparent that for polyP8 the difference of emission between control and PPX digestion is lower than that obtained for longer polyPs. This can be rationalized by the fact that digestion of polyP8 results in a higher PPi : Pi ratio as compared to the digestion of longer chain-length polyPs that release less PPi overall. Since the sensor shows no response to Pi, but a small response to PPi, the larger difference can therefore be rationalised.
Conclusions
In summary, two novel fluorescent ESIPT turn-on sensors have been successfully designed. They specifically detect short-chain inorganic polyphosphates over a range of different other condensed phosphates in aqueous solution. They operate through release of a metal ion quenched fluorophore by decomplexation of Cu2+ with the analyte. The probe preferentially detects polyPs over other relevant biologically occurring phosphates, pyrophosphates and nucleotides like ATP, ADP, GTP. An optimal fluorescence response has been achieved specifically in presence of polyP8. Additionally, the probe showed selectivity towards linear polyPs over other comparable cyclic metaphosphates. The sensor can cycle in ‘turn-off–turn-on’ fluorescence experiments upon consecutive additions of Cu2+ and polyP8, underscoring its reversible and sensitive performance in an aqueous environment. Furthermore, sensor 6 is suitable to monitor polyP digestion by exopolyphosphatase PPX in an endpoint experiment. Sensors 6 and 7 are the first tailored ESIPT-ON decomplexation sensors that operate in water to selectively detect short-chain polyphosphates. Their further development into vacuolar sensors thus seems feasible and will be the topic of follow-up studies. Short-chain polyphosphates may have escaped previous detection approaches, as the usually applied DAPI and JC-D dyes are only responsive to chain lengths beyond 15.1d These novel sensors may thus close an important gap in current polyP research, where detection can still be quite limiting,9 and inspire the generation of tailored derivatives with improved sensing properties.
Author contributions
S. K. R. synthesized the probes and evaluated their photophysical properties. S. K. R. performed the PPX assay. S. K. R. wrote the first draft of the manuscript and prepared the figures. S. M. synthesized the linear polyphosphates. T. D. M. synthesized the metaphosphates. R. H. developed initial sensor concepts. H. J. J. conceived the project and provided feedback on the draft manuscript. All authors contributed to finalizing the manuscript.
Data availability
Additional datasets are available in the ESI and from the corresponding author upon request. The X-ray crystallography data have been deposited at the Cambridge Crystallographic Data Centre (CCDC), under accession number CCDC 2352054 and 2361756.†
Conflicts of interest
There are no conflicts to declare.
Supplementary Material
Acknowledgments
This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement no. 864246, to H. J. J.). This study was supported by the Deutsche Forschungsgemeinschaft (DFG) under Germany's excellence strategy (CIBSS, EXC-2189, Project ID 390939984, to H. J. J.). We acknowledge RegeneTiss Inc for providing polyphosphates.
Electronic supplementary information (ESI) available. CCDC 2352054 and 2361756. For ESI and crystallographic data in CIF or other electronic format see DOI: https://doi.org/10.1039/d4ob01926a
References
- (a) Rao N. N. Gómez-Garća M. R. Kornberg A. Annu. Rev. Biochem. 2009;78:605–647. doi: 10.1146/annurev.biochem.77.083007.093039. [DOI] [PubMed] [Google Scholar]; (b) Müller W. E. G. Schröder H. C. Wang X. Chem. Rev. 2019;119:12337–12374. doi: 10.1021/acs.chemrev.9b00460. [DOI] [PMC free article] [PubMed] [Google Scholar]; (c) Holmström K. M. Marina N. Baev A. Y. Wood N. W. Gourine A. V. Abramov A. Y. Nat. Commun. 2013;4:1362. doi: 10.1038/ncomms2364. [DOI] [PMC free article] [PubMed] [Google Scholar]; (d) Christ J. J. Willbold S. Blank L. M. Anal. Chem. 2020;92:4167–4176. doi: 10.1021/acs.analchem.9b05144. [DOI] [PubMed] [Google Scholar]
- (a) Morrissey J. H. Choi S. H. Smith S. A. Blood. 2012;119:5972–5979. doi: 10.1182/blood-2012-03-306605. [DOI] [PMC free article] [PubMed] [Google Scholar]; (b) Kulaev I. S., Vagabov V. M. and Kulakovskaya T. V., The Biochemistry of Inorganic Polyphosphates, 2nd edn, John Wiley & Sons: Chichester, UK, 2004 [Google Scholar]
- (a) Kumble K. D. Kornberg A. J. Biol. Chem. 1995;270:5818–5822. doi: 10.1074/jbc.270.11.5818. [DOI] [PubMed] [Google Scholar]; (b) Wang L. Fraley C. D. Faridi J. Kornberg A. Roth R. A. Proc. Natl. Acad. Sci. U. S. A. 2003;100:11249–11254. doi: 10.1073/pnas.1534805100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim G., Qiu D., Jessen H. J. and Mayer A., 2023; mBio14:e00102-23
- Hernandez-Ruiz L. González-García I. Castro C. Brieva J. A. Ruiz F. A. Haematologica. 2006;91:1180–1186. [PubMed] [Google Scholar]
- (a) Smith S. A. Morrissey J. H. Curr. Opin. Hematol. 2014;21:388–394. doi: 10.1097/MOH.0000000000000069. [DOI] [PMC free article] [PubMed] [Google Scholar]; (b) Smith S. A. Mutch N. J. Baskar D. Rohloff P. Docampo R. Morrissey J. H. Proc. Natl. Acad. Sci. U. S. A. 2006;103:903–908. doi: 10.1073/pnas.0507195103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Moreno-Sanchez D. Hernandez-Ruiz L. Ruiz F. A. Docampo R. J. Biol. Chem. 2012;287:28435–28444. doi: 10.1074/jbc.M112.385823. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Samper-Martin B. Sarrias A. Lazaro B. Perez-Montero M. Rodriguez-Rodriguez R. Ribeiro M. P. C. Banon A. Wolfgeher D. Jessen H. J. Alsina B. et al. Cell Rep. 2021;37:110004. doi: 10.1016/j.celrep.2021.110004. [DOI] [PubMed] [Google Scholar]; (b) Gray M. J. Jakob U. Curr. Opin. Microbiol. 2015;24:1–6. doi: 10.1016/j.mib.2014.12.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Desfougères Y. Saiardi A. Azevedo C. Biochem. Soc. Trans. 2020;48:95–101. doi: 10.1042/BST20190328. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Moreno B. Urbina J. A. Oldfield E. Bailey B. N. Rodrigues C. O. Docampo R. J. Biol. Chem. 2000;275:28356–28362. doi: 10.1074/jbc.M003893200. [DOI] [PubMed] [Google Scholar]; (b) Ruiz F. A. Rodrigues C. O. Docampo R. J. Biol. Chem. 2001;276:26114–26121. doi: 10.1074/jbc.M102402200. [DOI] [PubMed] [Google Scholar]
- Mordhorst S. Singh J. Mohr M. K. F. Hinkelmann R. Keppler M. Jessen H. J. Andexer J. N. ChemBioChem. 2019;20:1019–1022. doi: 10.1002/cbic.201800704. [DOI] [PubMed] [Google Scholar]
- (a) Wang D. Li Y. Cope H. A. Li X. He P. Liu C. Li G. Rahman S. M. Tooker N. B. Bott C. B. Onnis-Hayden A. Singh J. Elfick A. Marques R. Jessen H. J. Oehmen A. Gu A. Z. Water Res. 2021;206:117726. doi: 10.1016/j.watres.2021.117726. [DOI] [PubMed] [Google Scholar]; (b) Blank L. M. Microb. Biotechnol. 2023;16:1616–1622. doi: 10.1111/1751-7915.14250. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Streichan M. Golecki J. R. Schön G. FEMS Microbiol. Lett. 1990;73:113–124. [Google Scholar]; (b) Kulakova A. N. Hobbs D. Smithen M. Pavlov E. Gilbert J. A. Quinn J. P. McGrath J. W. Environ. Sci. Technol. 2011;45:7799–7803. doi: 10.1021/es201123r. [DOI] [PubMed] [Google Scholar]; (c) Omelon S. Georgiou J. Henneman Z. J. Wise L. M. Sukhu B. Hunt T. Wynnyckyj C. Holmyard D. Bielecki R. Grynpas M. D. PLoS One. 2009;4:e5634. doi: 10.1371/journal.pone.0005634. [DOI] [PMC free article] [PubMed] [Google Scholar]; (d) Aschar-Sobbi R. Abramov A. Y. Diao C. Kargacin M. E. Kargacin G. J. French R. J. Pavlov E. J. Fluoresc. 2008;18:859–866. doi: 10.1007/s10895-008-0315-4. [DOI] [PubMed] [Google Scholar]; (e) Diaz J. M. Ingall E. D. Environ. Sci. Technol. 2010;44:4665–4671. doi: 10.1021/es100191h. [DOI] [PubMed] [Google Scholar]; (f) Gomes F. M. Ramos I. B. Wendt C. Girard-Dias W. De S. W. Machado E. A. Miranda K. Eur. J. Histochem. 2013;57:e34. doi: 10.4081/ejh.2013.e34. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Diaz J. M. Ingall E. D. Environ. Sci. Technol. 2010;44:4665–4671. doi: 10.1021/es100191h. [DOI] [PubMed] [Google Scholar]; (b) Ohtomo R. Sekiguchi Y. Kojima T. Saito M. Anal. Biochem. 2008;383:210–216. doi: 10.1016/j.ab.2008.08.002. [DOI] [PubMed] [Google Scholar]
- (a) Martin P. Mooy B. A. S. V. Appl. Environ. Microbiol. 2013;79:273–281. doi: 10.1128/AEM.02592-12. [DOI] [PMC free article] [PubMed] [Google Scholar]; (b) Kolozsvari B. Parisi F. Saiardi A. Biochem. J. 2014;460:377–385. doi: 10.1042/BJ20140237. [DOI] [PubMed] [Google Scholar]
- Angelova P. R. Agrawalla B. K. Elustondo P. A. Gordon J. Shiba T. Abramov A. Y. Chang Y.-T. Pavlov E. V. ACS Chem. Biol. 2014;9:2101–2110. doi: 10.1021/cb5000696. [DOI] [PubMed] [Google Scholar]
- Wongkongkatep J. Ojida A. Hamachi I. Top. Curr. Chem. 2017;375:30. doi: 10.1007/s41061-017-0120-0. [DOI] [PubMed] [Google Scholar]
- (a) Sedgwick A. C. Wu L. Han H.-H. Bull S. D. He X.-P. James T. D. Sessler J. L. Tang B. Z. Tian H. Yoon J. Chem. Soc. Rev. 2018;47:8842–8880. doi: 10.1039/c8cs00185e. [DOI] [PubMed] [Google Scholar]; (b) Murale D. P. Kim H. Choi W. S. Churchill D. G. Org. Lett. 2013;15:3946–3949. doi: 10.1021/ol4017222. [DOI] [PubMed] [Google Scholar]; (c) Nehra N. Kaushik R. Anal. Methods. 2023;15:5268–5285. doi: 10.1039/d3ay01249b. [DOI] [PubMed] [Google Scholar]; (d) Gu H. Wang W. Wu W. Wang M. Liu Y. Jiao Y. Wang F. Wang F. Chen X. Chem. Commun. 2023;59:2056–2071. doi: 10.1039/d2cc06556h. [DOI] [PubMed] [Google Scholar]
- (a) Zheng Q. Ding F. Hu X. Feng J. Shen J. He X. Bioorg. Chem. 2021;109:104746. doi: 10.1016/j.bioorg.2021.104746. [DOI] [PubMed] [Google Scholar]; (b) Das J. Ta S. Das D. New J. Chem. 2023;47:18126–18129. [Google Scholar]; (c) Chen W.-H. Xing Y. Pang Y. Org. Lett. 2011;13:1362–1365. doi: 10.1021/ol200054w. [DOI] [PubMed] [Google Scholar]; (d) Wang J. Li Y. Patel N. G. Zhang G. Zhoub D. Pang Y. Chem. Commun. 2014;50:12258–12261. doi: 10.1039/c4cc04731a. [DOI] [PMC free article] [PubMed] [Google Scholar]; (e) Wang H. Shi D.-L. Li J. Tang H.-Y. Li J. Guo Y. Sens. Actuators, B. 2018;256:600–608. [Google Scholar]
- (a) Xu Y. Q. Pang Y. Chem. Commun. 2010;46:4070–4072. doi: 10.1039/c003230a. [DOI] [PubMed] [Google Scholar]; (b) An M. Kim B. Y. Seo H. Helal A. Kim H. S. Spectrochim. Acta, Part A. 2016;169:87–94. doi: 10.1016/j.saa.2016.06.026. [DOI] [PubMed] [Google Scholar]
- Yadav P. Jakubaszek M. Spingler B. Goud B. Gasser G. Zelder F. Chem. – Eur. J. 2020;26:5717–5723. doi: 10.1002/chem.201905686. [DOI] [PubMed] [Google Scholar]
- Hager E. B. Makhubela B. C. E. Smith G. S. Dalton Trans. 2012;41:13927–13935. doi: 10.1039/c2dt31471a. [DOI] [PubMed] [Google Scholar]
- Martínez-Máñez R. Sancenón F. Chem. Rev. 2003;103:4419. doi: 10.1021/cr010421e. [DOI] [PubMed] [Google Scholar]
- Fu Y. Feng Q. C. Jiang X. J. Xu H. Li M. Zang S. Q. Dalton Trans. 2014;43:5815–5822. doi: 10.1039/c3dt53281j. [DOI] [PubMed] [Google Scholar]
- (a) Roy B. Rao A. S. Ahn K. H. Org. Biomol. Chem. 2011;9:7774–7779. doi: 10.1039/c1ob05999h. [DOI] [PubMed] [Google Scholar]; (b) Li Z. Qiang J. Li J. Wei T. Zhang Z. Chen Y. Kong Q. Wang F. Chen X. Dyes Pigm. 2019;163:243–248. [Google Scholar]; (c) Chang Y. Qin H. Wang X. Li X. Li M. Yang H. Xu K. Qing G. ACS Sens. 2020;5:2438–2447. doi: 10.1021/acssensors.0c00619. [DOI] [PubMed] [Google Scholar]; (d) Wang Y. Hou X. Li Z. Zhou Q. Lei M. Hu S. Wu X. Li C. Xu Z. Wang Y. Anal. Methods. 2018;10:5790–5796. [Google Scholar]
- (a) Singh J. Steck N. De D. Hofer A. Ripp A. Captain I. Keller M. Wender P. A. Bhandari R. Jessen H. J. Angew. Chem., Int. Ed. 2019;58:3928–3933. doi: 10.1002/anie.201814366. [DOI] [PubMed] [Google Scholar]; (b) Singh J. Ripp A. Haas T. M. Qiu D. Keller M. Wender P. A. Siegel J. S. Baldridge K. K. Jessen H. J. J. Am. Chem. Soc. 2019;141(38):15013–15017. doi: 10.1021/jacs.9b08273. [DOI] [PMC free article] [PubMed] [Google Scholar]; (c) Jessen H. J. Dürr-Mayer T. Haas T. M. Ripp A. Cummins C. C. Acc. Chem. Res. 2021;54:4036–4050. doi: 10.1021/acs.accounts.1c00370. [DOI] [PubMed] [Google Scholar]
- Mei Q. Shi Y. Hua Q. Tong B. RSC Adv. 2015;5:74924–74931. [Google Scholar]
- Haas T. M. Mundinger S. Qiu D. Jork N. Ritter K. Dürr-Mayer T. Ripp A. Saiardi A. Schaaf G. Jessen H. J. Angew. Chem., Int. Ed. 2022;61:e202112457. doi: 10.1002/anie.202112457. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (a) Haas T. M. Wiesler S. Dürr-Mayer T. Ripp A. Fouka P. Qiu D. Jessen H. J. Angew. Chem., Int. Ed. 2022;61:e202113231. doi: 10.1002/anie.202113231. [DOI] [PMC free article] [PubMed] [Google Scholar]; (b) Bezold D. Dürr T. Singh J. Jessen H. J. Chem. – Eur. J. 2020;26:2298–2308. doi: 10.1002/chem.201904433. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Additional datasets are available in the ESI and from the corresponding author upon request. The X-ray crystallography data have been deposited at the Cambridge Crystallographic Data Centre (CCDC), under accession number CCDC 2352054 and 2361756.†