Hybrid dark-field and attenuation contrast retrieval for laboratory-based X-ray tomography

Adam Doherty 1,2,*, Ian Buchanan 1, Oriol Roche i Morgó 1,2, Alberto Astolfo 1, Savvas Savvidis 1, Mattia F M Gerli 3,4, Antonio Citro 5, Alessandro Olivo 1, Marco Endrizzi 1,2
PMCID: PMC11674740  PMID: 39735734

Abstract

X-ray dark-field imaging highlights sample structures through contrast generated by sub-resolution features within the inspected volume. Quantifying dark-field signals generally involves multiple exposures for phase retrieval, separating contributions from scattering, refraction, and attenuation. Here, we introduce an approach for non-interferometric X-ray dark-field imaging that presents a single-parameter representation of the sample. This fuses attenuation and dark-field signals, enabling the reconstruction of a unified three-dimensional volume. Notably, our method can obtain dark-field contrast from a single exposure and employs conventional back projection algorithms for reconstruction. Our approach is based on the assumption of a macroscopically homogeneous material, which we validate through experiments on phantoms and on biological tissue samples. The methodology is implemented on a laboratory-based, rotating anode X-ray tube system without the need for coherent radiation or a high-resolution detector. Utilizing this system with streamlined data acquisition enables expedited scanning while maximizing dose efficiency. These attributes are crucial in time- and dose-sensitive medical imaging applications and unlock the ability of dark-field contrast with high-throughput lab-based tomography. We believe that the proposed approach can be extended across X-ray dark-field imaging implementations beyond tomography, spanning fast radiography, directional dark-field imaging, and compatibility with pulsed X-ray sources.

1. INTRODUCTION

In X-ray dark-field and phase-contrast imaging, contrast is generated by the phase changes imparted to the radiation as it traverses the sample. Sensitivity to these contrast channels requires the use of specialized setups, often implemented with synchrotron radiation that offers high flux and coherence, but also adapted to laboratory-scale equipment. We focus here on edge illumination [1], for its applicability with rotating anode X-ray sources [2], robustness [3], and negligible coherence conditions (both spatial and temporal) [4] and because it is an approach that allows for uniform sampling of the illumination across a cm-sized field of view [5], which is important for single-shot imaging.

In phase-sensitive X-ray setups, the intensity reaching the detector is modulated by both attenuation and phase effects and separating these signals into attenuation, (differential) phase, and dark-field images typically requires taking multiple exposures under different conditions. Such examples include changing the propagation distance [6], rocking of a crystal analyzer [7], lateral movement of phase gratings [810], lateral movements of diffusers [1114], or lateral movements of absorbing masks [15]. Alternatively, this can be done with a single exposure by finely sampling the wavefront but comes at a cost of reducing the system resolution below that of the detector pixel size, which has been shown with radiation structured by interference gratings [16], diffusers [17], structured grids [18,19], and absorbing masks [20]. However, such techniques often make use of multiple exposures to compensate for the resolution loss from a single-shot approach [2123].

Single-shot approaches to phase-contrast imaging that do not rely on high-resolution detectors often rely on the assumption of a homogeneous object approximation, which links the real and imaginary parts of the refractive index of the material under investigation [24]. This has recently been expanded in the case of single-shot dark-field retrieval using synchrotron radiation [25,26]. We use a similar approach, but make use of a macroscopic-homogeneous object approximation to instead link the attenuation and dark-field signals. This is demonstrated with a lab-based system, and we show the benefits on the data-intensive application of tomography acquisition and reconstruction.

In this work we introduce a novel retrieval method to extract dark-field contrast with a single measurement. The laboratory-based system is first described in Section 1.A. Then we show our model that allows retrieval of the dark-field contrast in a single exposure in the case of a pure phase object in Section 2. We then extend this to moderately attenuating but macroscopically homogeneous samples for a hybrid attenuation and dark-field contrast for tomography in Section 2.A. Finally, we discuss the validity of this approach and show example tomographic reconstructions with biological samples in Section 3.

A. Edge-Illumination Setup

A schematic of an edge illumination system is shown in Fig. 1(a). The system uses an absorbing mask that has a one-dimensional periodic structure that modulates the beam into a series of independent beamlets. These beamlets are then absorbed, refracted, and scattered by the sample. A second mask is placed just before the detector to analyze the profiles of these beamlets by creating insensitive regions on the detector pixel, and thus scattered radiation can be selectively measured by moving the sample mask to misalign the beamlets with the detector mask aperture. The one-dimensional shape means that phase sensitivity is along the direction between beamlets, and each beamlet is associated with one detector pixel.

Fig. 1.

Fig. 1.

(a) Edge illumination system schematic with radiation from an X-ray tube source modulated by the sample mask before reaching the sample, and then travelling towards the detector mask and detector. (b) Typical illumination curves (IC), i.e., the intensity acquired by one pixel when the sample mask is translated along the x-axis through one period [see arrow in (c)], and the effect on an illumination curve for purely attenuating, refracting, and scattering samples. (c), (d) Single beamlets are shown for a pictorial description of those effects, for the mask position corresponding to the peak in the illumination curve. A drop of intensity is expected at this position from both attenuation as well as scattering effects, associated with the dark-field signal. Sensitivity to the effects of (e) attenuation, (f) refraction, and (g) dark-field scattering as a function of the illumination curve position. These are calculated from the normalized magnitude of the intensity change from a small signal from each channel.

The experiments in this work were performed with the prototype system developed at UCL. This setup comprises an X-ray source, detector, and two periodic masks. The X-ray source is a Rigaku MicroMax-007 HF (Rigaku, Japan) with a molybdenum rotating anode and an effective focal spot size of approximately 70 µm, which was operated at 40 kVp and 30 mA for all results presented here. No additional filtration to the inherent 200 µm Be window was used. The detector was a CMOS-based flat-panel C9732DK-11 (Hamamatsu, Japan) with 50×50µm2 pixels and was placed at 85 cm from the source. The sample mask was placed at 68.5 cm from the source. Masks were made of Au on a graphite substrate and were manufactured, to the authors’ design, by Creatv MicroTech (Potomac, MD). The sample mask had an aperture size of 10 µm and a period of 79 µm, while the detector mask had an aperture size of 17 µm and a period of 98 µm. The periods match each other after taking into account the geometric magnification. The detector mask was placed just in front of the detector with the mask period matching twice the detector pixel period, after projection onto the detector plane. Both masks were in total 400 µm thick, consisting of a graphite substrate, and the absorbing sections of the masks made of 120 µm of Au. The sample was placed just behind the sample mask, leading to a geometric magnification of approximately 1.2. A full characterization of the system can be found in Havariyoun et al. [27].

Imaging with the edge illumination system is through the acquisition and processing of each pixel’s illumination curve. This is the intensity measured by one pixel as the sample mask and sample are translated in one period, creating an offset between the sample mask and the detector mask and detector. A series of exposures is taken during this procedure at different positions between the sample mask and the detector mask along the x-axis—with the resulting measurements for each pixel forming the illumination curve. A model illumination curve is shown in Fig. 1(b) with the effects of attenuation, refraction, and scattering demonstrated if a sample was placed in the beam. A Gaussian function is a well-established approximation for the illumination curve [15]. However, a Gaussian poorly captures the tails of the illumination curves, with an “offset” occasionally used to improve the retrieval [28,29]. The exact origin of the offset is not well understood and is higher than the expected transmission through the masks of roughly 1% at our energy and mask dimensions. The dark-field image is retrieved through fitting Gaussian functions to the data acquired for each illumination curve [30], with the change in the area under the illumination curve corresponding to attenuation, the shift in center position to refraction or differential phase, and the increase in width to scattering or dark-field contrast. In the case of tomography [31], the procedure needs to be repeated for each viewing angle, and thus the amount of images required is the number of sampling points along the illumination curve times the number of viewing angles, NIC×Nproj .

In an edge illumination system, spatial resolution can be improved through a procedure known as dithering, where the sample is translated in small steps along the x-axis, subsequently exposing parts of the sample that have not been illuminated. In the case of full illumination curve sampling, this further increases the acquisition dimensionality to three and the number of exposures to NIC×Ndith×Nproj . It should be noted that tomography is possible without dithering with a single exposure per projection angle [32]. Here, the spatial resolution will be ultimately limited by the pixel size, as with conventional X-ray imaging systems [33]. Furthermore, techniques are under development for retaining this spatial resolution improvement without fully dithering the sample for reducing the number of necessary exposures [34].

The model and methodology presented here allow retrieval of dark-field contrast in a single shot with a stationary sample mask (i.e., no illumination curve scanning, NIC=1 ), reducing the acquisition dimensionality by one for all dark-field acquisitions. The proposed method additionally does not require curve fitting and hence it also substantially speeds up an otherwise computationally intensive data processing.

2. SINGLE-SHOT DARK-FIELD MODEL

The basis for single-shot dark-field imaging with edge illumination is a convolution model of the illumination curve. The illumination curve without the sample is denoted as the reference Ir(x¯) :

Ir(x¯)=A2πσr2exp[(x¯x¯0)22σr2], (1)

where x¯ indicates the displacement of the sample mask along the x-axis, A is a constant determining the amplitude of the curve, σr2 is the variance (width) of the Gaussian curve, and x¯0 is the position of alignment between the sample and the detector apertures These parameters all define the shape of the illumination curve without the sample, and are dependent on source power, mask aperture sizes, system geometry, and detector efficiency. Note that these parameters [A,x¯0,σr2] are all pixel-wise and vary between illumination curves across the detector. Variations in x¯0 can originate from mask imperfections or misalignment. Single-shot dark-field retrieval requires imaging at the same point on each illumination curve across the detector, meaning variations in x¯0 should be minimized but these can be reduced to well below a micron across the whole field of view [5,35]. We will assume x¯0 to be constant for all pixels. Variations in σr2 are less critical and can be accounted for by pixelwise correction, but we can assume this parameter to be constant without a significant performance loss.

When a sample is in the beam, the illumination curve is denoted as the sample illumination curve Is(x¯) and includes three additional terms:

Is(x¯)=tA2π(σr2+σo2)exp[(x¯x¯0Δx¯ref)22(σr2+σo2)], (2)

with t quantifying the change in area from attenuation, Δx¯ref quantifying the lateral shift from refraction, and σo2 quantifying the broadening in angular distribution from scattering (dark-field). Calculating these three parameters on a pixel-by-pixel basis yields attenuation, refraction, and dark-field contrast images.

In the convolution model, the dark-field signal, quantified by σo2 , is the width of the scattering function associated with each part of the sampled object. As such, dark field is measured in units of length squared and is then converted to squared angle distribution by dividing by the squared propagation distance. This approach for the measurement of dark field signals then is independent of system geometry [36]. The convolution model is also used in grating interferometry [10,3739], speckle-based imaging [12,40], and single-grid imaging [22,41,42]. However, such systems generally measure a visibility reduction associated with dark-field blurring and can then optionally convert this into a scattering angle. For a system based on interferometric methods, such conversions will only yield a stable value when the scattering feature size is smaller than the system’s autocorrelation length [43]. In edge-illumination, where sampling beamlets do not interact with each other, the autocorrelation length is typically less than 1 µm and as such, the retrieved scattering angle tends to be consistent despite changes in mask period [36]. To our knowledge, there is only one publication that experimentally compares edge-illumination dark-field measurements to other phase sensitive systems, this time to dark field with speckle-based imaging, which found a poor qualitative match between the two systems [44]. However a full comparison is difficult due to the broad range of different algorithms published to retrieve dark field with interference-based dark-field imaging.

The effects of the attenuation and refraction signals must be isolated or excluded for retrieving σo2 from a single measurement. The sensitivity to each contrast channel is a function of the mask offset and hence can be optimized accordingly based on where on the illumination curve this measurement it taken. This is presented through a simple model in Figs. 1(e)1(g), where the absolute change in intensity is plotted across the illumination curve for a small signal from each of the three contrast channels, calculated as Ir(x¯)Is(x¯)Ir(x¯) . Strictly speaking these sensitivity curves depend on the absolute signal in each contrast channel; however the sensitivity plots we report are typical curves given the signal level experienced in many imaging cases. Sensitivity to refraction is linked to the gradient of the illumination curve [45], and hence it is minimized at the peak and tails, which is also where sensitivity to the dark-field broadening is highest. Sensitivity to the attenuation signal is highest at the peak. For single-shot dark-field imaging, we chose to expose at the peak of the illumination curves [see Fig. 1(d)]. At this position, the intensity changes when the illumination curve arising from a lateral shift is minimized, whereas the change due to broadening is maximized. We also note that this illumination is the most dose-efficient with little X-ray intensity lost in the detector mask.

At the peak of the illumination curve, i.e., when x¯=x¯0 , the measured signals for the reference and sample illumination curves are as follows:

Ir(x¯=x¯0)=A2πσr2, (3)
Is(x¯=x¯0)=tA2π(σr2+σo2)exp[Δx¯ref22(σr2+σo2)]. (4)

The assumption for single-shot dark-field imaging is that the shift in the center position is small compared to the width of the curve, i.e.,  Δx¯ref2σr2 . This comes about from the peak of the illumination curve being flat, meaning a small lateral shift will not lead to a large change in intensity. As such, refraction effects can be neglected and sensitivity to scattering is retained, reducing the number of unknowns to two (t and σo2 ).

The validity of this assumption depends on the system and sample being scanned. For a system with relatively wide apertures, the illumination curves will be broad (large σr2 ) and hence larger refraction angles could be tolerated. In terms of the sample, refraction occurs at material boundaries, whereas attenuation and scattering typically happen in the bulk of the sample, although some scattering is seen at material boundaries [25]. For the system being employed here, this assumption is valid away from material boundaries, where some intensity change is likely to come from refraction.

The above conditions allow for a simplification in Eq. (4) where exp[Δx¯ref22(σr2+σo2)]1 . The following step involves taking the ratio between Eqs. (3) and (4) and squaring the result to obtain

Ir2(x¯=x¯0)Is2(x¯=x¯0)=σr2+σo2t2σr2. (5)

Rearranging this to solve the dark-field signal gives the equation for dark-field retrieval:

σo2=σr2[t2Ir2(x¯=x¯0)Is2(x¯=x¯0)1], (6)

and defining Ω=Ir2(x¯=x¯0)Is2(x¯=x¯0) this can be written in more compact form as

σo2=σr2(t2Ω1), (7)

with the dark-field signal expressed as a function of the width of the reference illumination curves, σr2 , the transmission signal, t, and the change in peak illumination curve measurement, quantified as  Ω .

In the case of a pure-phase object where t=1 , then Eq. (7) allows the retrieval of the dark-field signal with a single exposure. As has been shown previously, the dark-field signal recovered with the edge-illumination system is compatible with tomography [31,46], and hence this approach allows retrieval of dark-field contrast with weakly attenuating samples with a single shot.

To demonstrate the compatibility with tomography we present the signal from a foamed polystyrene wedge that only produced around 1.5% attenuation at its thick edge. The dimensions of the wedge are roughly 16×10mm along the x and z axes, respectively. At the energy employed here, the refractive index terms are δ=1.37×108 and β=5.35×1012 [47]. This was scanned with 16 dithering steps and 1.2 s exposure per frame, with nine illumination curve points taken centered around the peak for conventional dark-field retrieval, with the peak measurement used for single-shot retrieval.

Images and profiles for this wedge in the dark-field channel retrieved using conventional and single-shot retrievals are presented in Fig. 2. These both show good linearity and the shape is consistent between the two profiles across the full wedge, but a small discrepancy between them [Fig. 2(j)] is present. This is partially from the assumption of a pure phase object not being true ( t0.99 at the thickest edge), but is also potentially arising from σr2 varying across the profile, mask misalignment across the field of view, and errors in the conventional multi-point dark-field retrieval [48]. Overall there is uncertainty when obtaining quantitative dark-field retrieval with any approach, but in this weak-attenuation regime the single-shot retrieval results in a profile that roughly matches that from conventional dark-field retrieval.

Fig. 2.

Fig. 2.

Images and profiles of polystyrene wedge phantom with (a)+(e) attenuation contrast, (b)+(f) dark-field contrast, (c)+(g) single-shot contrast using Eq. (7), assuming t=1 , and (d)+(h) the absolute value of the refraction signal, |Δx¯ref| . Profiles are taken by averaging all rows within the green ROI, with error bars taken as the standard deviation in the y-axis of the image, and graph horizontal axes correspond the to x-coordinates of the image. The sub-resolution features are resolved in (i) using a light microscope. Conventional and single-shot dark-field contrast are shown together in (j). The profiles match exactly at the thinnest edge due to the lack of attenuation, and start to deviate as the sample shows higher attenuation as the wedge thickness increases, breaking the assumption of a pure-phase object.

A. Extension to Tomography with Attenuating Samples

Solving Eq. (7) to obtain a dark-field image with a single exposure of the sample still requires knowledge of the transmission, t. An initial approach is the assumption of a phase object, where transmission can be assumed to be unity. For samples showing non-negligible attenuation, simply substituting t=1 in Eq. (7) results in a signal that is unsuitable for tomography because it cannot be expressed as an integral as the X-ray path through the sample [see Fig. 3(j)]. Reconstructing this signal would lead to cupping artifacts, where the center of absorbing objects will be brighter or darker than expected, similar to those seen with beam hardening. Non-linear projection intensity is common in polychromatic X-ray tomography and reconstruction algorithms exist to account for this [49,50]; however, our dependence on thickness is superlinear rather than the sublinear signal present with beam hardening. Furthermore, these methods tend to be model specific, and hence a dedicated model based on the intensity measured with dark-field sensitive setups is required.

Fig. 3.

Fig. 3.

Images and profiles of paper wedge phantom with (a)+(e) attenuation contrast, (b)+(f) dark-field contrast, (c)+(g) single-shot hybrid contrast using Eq. (14) with γ=551mrad2 , and (d)+(h) the absolute value of the refraction signal, |Δx¯ref| . Profiles are taken by averaging all rows within the green ROI, with error bars taken as the standard deviation in the y-axis of the image, and plot horizontal axes correspond to the x-coordinates of the image. The sub-resolution features of the paper fibers are resolved in (i) using a light microscope. Additionally in (j) we show the signal retrieved using Eq. (7) with t=1 alongside the conventional dark-field signal, where a large discrepancy is found and the signal is overestimated due to the non-negligible contribution from attenuation that is not accounted for. We show the same in (k) for the linearized single-shot hybrid contrast, where a linear signal that is much closer to the conventional dark-field signal is retrieved.

We propose an approach based on a relation between the attenuation and dark-field signals to linearize the single-shot contrast and reduce our model to a single unknown. We can constrain the solution of Eq. (7) by imposing a macroscopically homogeneous material approximation where the ratio between the attenuation and scattering signal is constant across the sample. We start by recognizing that both the attenuation signal and dark-field signal can be expressed as the linear integral along the X-ray propagation axis:

ln[t(x,y)]=μ(x,y,z)dz, (8)
σo2(x,y)=ϵ(x,y,z)dz, (9)

where [x,y,z] represent the system coordinates, μ is the linear attenuation coefficient, and ϵ is the linear scattering coefficient that can be reconstructed in edge-illumination dark-field tomography [31].

For a material with a constant relation between attenuation and dark-field scattering, we can define a new parameter:

γ(x,y,z)=μ(x,y,z)ϵ(x,y,z), (10)

which will be constant across the sample as with the definition of a macroscopically homogeneous sample (i.e.,  γ=γ(x,y,z) ). We now take the ratio between the retrieved attenuation and dark-field projections as

ln[t(x,y])σo2(x,y)=μ(x,y,z)dzϵ(x,y,z)dz. (11)

Inserting Eq. (10) into the above and noting that γ being a constant allows the removal of the integral and position dependencies, we end up with the following definition of γ in projection space:

γ=ln(t)σo2, (12)

which is a constant for a given sample, with units of mrad2 , or the inverse of dark-field imaging units. This equation effectively assumes a macroscopically homogeneous sample. We note that this does not imply a homogeneous microstructure, i.e., one without density variations, which would result in a sample with weak scattering. Hence we clarify this as an assumption of macroscopic homogeneity, with the attenuation and dark field being related to one another across the macroscale, but density variations or heterogeneity allowed on the microscale to scatter the radiation. The simplest examples where this is valid are single-material samples [29].

This is inspired by Paganin retrieval [24,51], where the real and imaginary parts of the refractive index are related, which effectively links the phase-contrast and attenuation signals. On first glance this would suggest redundancy between the two contrast channels; however, the much higher signal-to-noise ratio associated with phase-contrast means Paganin retrieval is widespread for synchrotron-based studies in plant science [52], material science [53], battery research [54], and tissue imaging [55]. This assumption has also been used to develop a single-shot approach to phase-contrast with multi-contrast lab-based imaging systems, including the edge-illumination imaging system [45,56].

The requirement for a constant γ is not going to be satisfied by all samples; for example, the complementarity between attenuation and dark-field contrast has been well documented [31,57], and is unlikely to hold for multi-material samples. We primarily introduce this as it allows for simplified retrieval with only a single unknown without any further knowledge or approximation about the scatterers. In this work we show retrievals for samples where this assumption holds well, and samples where this is not completely satisfied, but our approach results in meaningful reconstructions.

The second assumption underlying the proposed approach is that attenuation is relatively low, although this is significantly extended beyond that seen with a pure phase object assumption. This allows for the second-order Taylor expansion in Eq. (12) to be a good approximation. Replacing t with 1a above gives the following expression after the Taylor expansion around ln(1a) :

ln(1a)a+a22, (13)

where a is the fraction of the beam attenuated by the sample. Note that through the homogeneous material approximation, this is also related to the dark-field signal. Substituting this into Eq. (12) and rearranging gives the following:

σo2=1γ(a+a22). (14)

Substituting this and t=1a into Eq. (7) gives the following polynomial:

0=(γΩ12)a2(2γΩ+1)a+(γΩγσr2), (15)

which is a quadratic whose roots can be found as

a=(2γΩ+1)±(2γΩ1)24(γΩ12)(γΩγσr2)2γΩ1, (16)

where it was the solution with the negative square root, which was found to give the solution that best matched the expected dark-field signal due to the performance in the limit of γ=0mrad2 . Both Eqs. (14) and (16) can be applied pixel-wise and used to solve for a dark-field image. Estimates for γ for each sample can be acquired from conventional retrievals using fully sampled datasets at a first angular projection, which provides averages of t and σo2 . It will approximate the true dark-field signal if (i) transmission is high, (ii) a homogeneous object can be assumed, and (iii) γ is correctly estimated. The first point holds up to where the Taylor expansion approximation around Eq. (12) starts to fail, but potentially more terms could be included for the more attenuating samples. The second and third requirements are more difficult to achieve with non-trivial samples. In practice, the single-shot retrieval is unlikely to yield a quantitative dark-field retrieval across the full image, but a qualitative tomographic reconstruction from a linear single-shot signal showing mixed attenuation and dark-field contrast is achievable with this approach. This is the origin of calling this single-shot retrieval a hybrid of the dark-field and attenuation signals when we make use of this linearization method.

We tested this approach on an attenuating wedge of uniform material, chosen as paper, with profiles shown in Fig. 3. The dimensions of the wedge are roughly 14.8×10mm along the x and z axes, respectively. At the energy employed here, the refractive index terms are δ=5.52×107 and β=3.59×1010 [47]. This was again scanned with 16 dithering steps and 1.2 s exposure per frame, with nine illumination curves taken centered around the peak for conventional dark-field retrieval, with the peak measurement used for single-shot retrieval. When assuming a pure phase object, the signal is non-linear, and additionally orders of magnitude higher intensity than the conventionally retrieved dark-field signal. This can be corrected for by using the linearization approach with Eqs. (14) and (16), which was successful in linearizing the signal and approximating the conventionally retrieved dark-field signal. The paper showed roughly 60% attenuation at its thick edge, and the successful linearization shows that this approach can be used to extend the working region of single-shot retrieval to much more strongly attenuating samples.

3. RESULTS AND DISCUSSION

We demonstrate the application of single-shot hybrid contrast to tomography on examples of biological tissues: a rat heart and vascularized endocrine pancreatic tissue. The heart was obtained from the UCL Biological Services Unit, from rats euthanized for organ harvesting via Schedule 1 methods, and critically point dried as per Savvidis et al. [58]. The vascularized endocrine pancreas tissue constructs were generated as per the protocol described by Citro et al. [59,60], with pancreatic islets embedded in the alveoli of the decellularized lung tissue. The critically point dried tissue was chosen, as dried tissue gives much stronger dark-field contrast compared to that of wet tissue.

Datasets were acquired with eight dithering steps, and 1200 angular views through 360. A separate heart dataset was acquired with full illumination curve sampling for a comparison with the conventional retrieval approach with seven illumination curve sampling points at 1.2 s per exposure. To match scan time, the heart scan for single-shot retrieval was acquired with 8.4 s per exposure with a single illumination curve sampling point. The pancreatic construct was taken with only 1.2 s per exposure for fast acquisition. The hybrid contrast projections were retrieved from this data using Eq. (14) and reconstructed with the standard filtered back projection algorithm.

All samples were successfully reconstructed with no obvious cupping artifacts that would be seen from poor signal linearity (see Supplement 1 (6.1MB, pdf) Fig. S1 for the effect of carrying out a reconstruction with an incorrect γ parameter). Figure 4 shows an axial slice through the middle of the rat heart sample. Dark-field contrast leads to intensity variations in the heart wall due to the different orientations of muscle fiber [31]. The hybrid contrast tomography image appears sharper and richer in detail. A Fourier ring correlation analysis with a three-sigma threshold criterion resulted in an FIRE value (see Ref. [61]) of 52 µm for the hybrid contrast slice, 55 µm for the dark-field slice, 60 µm for the attenuation slice, and 28 µm for the phase-contrast slice. This is partly due to the enhanced contrast at tissue-air interfaces associated with dark-field imaging, but also the improved statistics of single-shot retrieval over conventional retrieval that comes with imaging at the peaks rather than sampling across the full illumination curve, as counts are lower towards the tails. Another possible contribution to the hybrid contrast slice is edge enhancement from the differential phase (refraction) signal that occurs particularly strongly at edges and material boundaries, which our model does not capture as we have low sensitivity to this signal. We additionally show the phase-contrast slice calculated by integrating the refraction signal, with this slice showing a similar level of detail to the hybrid contrast. However, the correlation between these channels can be misleading, as it is the differential phase that might contribute to the hybrid contrast slice, which is a signal that cannot be reconstructed into a tomographic slice.

Fig. 4.

Fig. 4.

Tomographic slices of dried rat heart sample shown with (a)+(e) attenuation contrast, (b)+(f) dark-field contrast, (c)+(g) phase-contrast, and (d)+(h) hybrid contrast with Eq. (14) and γ=187mrad2 . All slices from datasets with matched total exposure time, with attenuation, phase, and dark field from a fully sampled dataset. Magnified sections in the blue ROI are shown below for the corresponding slices in (e)–(h). The hybrid contrast retains area contrast in the wall (orange arrows) from the dark-field slice, not present in the attenuation slice. Additionally, the inserts show much more detail with hybrid contrast than attenuation contrast.

The pancreatic construct is shown in Fig. 5 where a bright layer on the inner surface is due to a strong scattering originating there. The bright spots are round-shaped pancreatic islets, and from a full illumination curve planar image, were found to show a high-attenuation signal. Simultaneous sensitivity to both contrast channels enables concurrent visualization of the islet and the subtle changes in porosity throughout the decellularized scaffold.

Fig. 5.

Fig. 5.

Vascularized endocrine pancreatic tissue sample composed of pancreatic islets embedded in a lung tissue construct. Projection taken with full illumination curve sampling retrieved with (a) attenuation contrast shows the spatial distribution of the islet cells and (b) dark-field contrast shows the lung tissue structure. In (c), a tomography slice at yellow dashed line from a hybrid contrast retrieval with Eq. (14) and γ=138mrad2 . This combines information from both channels and can be visualized as (d) a full volume of joint contrast tomographic scan.

All these reconstructions rely on the assumption of insensitivity to the refraction signal when imaging at the peaks of the illumination curve, with the magnitude of the lateral shift in the illumination curve being much smaller than the broadening. From the wedges (Figs. 2 and 3), the magnitude of the refraction signal is much smaller than the square root of the width of the reference illumination curve, i.e.,  Δx¯ref∥≪σr , with the latter term being measured at around 8–9 µm depending on the scan. As a quantitative comparison, a strong refraction signal is present at the tissue-air interface for the heart sample of around 2 µm (refraction angle of 12 µrad). Using Eqs. (3) and (4) with typical values of A = 200 and σr2=81µm2 , this leads to a drop in peak illumination curve intensity of around 2.5%. The same approach can be used to calculate the same signal and would be found from a purely scattering sample at around σo2=4µm2(146µrad2) , whereas the measured dark-field signal at this region of the sample is around an order of magnitude higher. There remains, however, a degree of uncertainty in this assessment because the magnitude of refraction signals is ultimately sample-dependent, and thus difficult to generalize beyond the observed cases. Overall, we believe the validity of our assumption and the general presence of dark-field signal at material boundaries means that we are safe to ignore refraction effects.

One area that may affect this single-shot approach is potential contributions of beam hardening. As with x-ray attenuation, dark-field scattering falls with increasing x-ray energy, and hence beam hardening will lead to cupping artifacts with the dark-field reconstruction. The effects of beam hardening on dark-field retrieval have been presented with systems based on interferometric methods [6264], but not yet with edge-illumination. Furthermore, when combining both contrast channels, beam hardening is likely to lead to a similar problem as with conventional x-ray imaging. The results shown here are with relatively weakly attenuating materials (excluding the paper sample), and hence we do not see clear beam hardening issues in our reconstructions.

From our examples with the wedges and biological tissue, we propose two cases where our approach could be beneficial: (a) where our assumptions hold with γ consistent across the whole sample, and secondly (b) where γ varies throughout the sample. See Supplement 1 (6.1MB, pdf) Fig. S2 for an assessment of how γ varies within the paper and heart samples. For either case, our approach could result in improved signal-to-noise ratio or contrast when compared to attenuation images, and the benefit of expedited scanning when compared to conventional dark-field acquisition.

In the first case, the attenuation and dark-field signals are linked with a constant ratio between them, resulting in a constant value of γ. These are the so-called macroscopic-homogeneous samples. The most basic example of this is the uniform wedge phantoms, where a single material is present and the density and microstructure remain consistent. In theory this could be extended to any sample where the attenuation and dark-field signals are linked, which could be single material samples with varying density of scatterers, or potentially multi-material if each material had the same γ. The benefit of using our hybrid contrast for these samples would be if the attenuation signal was poor, such as with the polystyrene phantom. Here, in the projections, the signal-to-noise ratio measured at the thickest part of the wedge rises from 7.0 to 10.8 from the attenuation and hybrid contrast slices, respectively.

The second is for more complex samples where dark-field and attenuation give differing, but somewhat proportional, contrast. This is the case for the heart and pancreas samples, where γ varies across the sample. Our retrieval approach uses only a single value across the whole image, and the result is a fusion of the two contrast channels into a hybrid contrast, with information present from both signals. This will be non-quantitative, corresponding to neither dark-field nor attenuation gray values; however the reconstruction can still provide a valid three-dimensional representation of morphology within the sample.

In practice, many complex samples are likely to hold a more complex relationship between the two contrast channels. Although both dark-field scattering and attenuation depend on chemical composite and density, scattering additionally depends on feature size and even orientation [43,6568]. One example case where our approach is unlikely to hold is that of a material with changing porosity, where optically sparse pores in a uniform media will present reduced attenuation but increased scattering. Different materials are in general expected to have different γ parameters; thus multi-material samples are unlikely to satisfy this approach. In future work, our approach could be adapted specifically to samples with multiple γ parameters. This is analogous to the extension of Paganin retrieval to multi-material samples [69,70]. These typically require prior knowledge or significant user input and as such, we believe our simple linear relationship provides a suitable retrieval approach for many non-trivial samples.

The tomographic reconstructions we present exhibit high signal-to-noise ratios, showcasing discernible features in both contrast channels. However, attributing intensity to either attenuation or dark field becomes challenging without prior knowledge of sample composition or separate datasets with conventionally retrieved images. While our approach sacrifices the ability to isolate these two contrast channels, the combination of both signals into a single reconstructed volume presents the substantial advantage of synthesizing the data into a single-parameter representation for user inspection. This is opposed to most image fusion methods [7174], which necessitate full sampling of modulation patterns, retrieval of separate contrast channels, and subsequent synthesis into a unified quantity. Our approach conducts fusion at the retrieval stage and is based on the physical properties of the three-dimensional distribution of materials or tissues under investigation.

Furthermore, our approach offers a notable advantage in that it is maximally efficient with respect to the dose delivered to the sample. This arises by enforcing the data collection at the top of the illumination curve where no primary beam is lost at the analyzer stage, and this exists uniformly across the entire field of view. This optimal data acquisition minimizes any loss of intensity after interaction with the sample, attributing intensity loss solely to contrast rather than to the modulation imposed by the analyzer. To illustrate, our approach is 100% efficient, surpassing alternatives such as a three-point retrieval method [15], which achieves 67% efficiency or lower, and uniform sampling along the illumination curve usually working at around 50% efficiency [30]. We think this is an important point towards the development of X-ray phase-contrast techniques compatible with pre-clinical and clinical imaging.

The versatility of this approach to visualize three different biological samples shows its efficacy to the volumetric investigation of tissue samples. The compact nature of the edge-illumination system, coupled with its utilization of incoherent radiation, makes it particularly well-suited for integration into a cabinet-based design. We believe employing the edge-illumination system with the proposed technique is well-suited for high-throughput analysis of tissue samples in laboratory or clinical settings. The feasibility of such use has been demonstrated before with breast tissue samples using a single-shot phase-contrast approach [32], with our proposed method extending the applicability to imaging scattering tissue.

4. CONCLUSIONS

We presented a model and method to obtain X-ray dark-field contrast with a single exposure, without the need for a high spatial or temporal coherence or a high-resolution detector. We derived an equation to retrieve the dark-field signal, which can be found in a single X-ray intensity measurement on pure-phase objects. This was then extended to tomography with more attenuating samples, demonstrating its effectiveness up to approximately 60% attenuation. Our approach for attenuating samples relies on a macroscopically homogeneous material approximation that enables linking the attenuation and dark-field signals within a sample and thus solving for two unknowns with only one measurement. In practice this results in an image with mixed dark-field and attenuation contrast (hybrid contrast), with features from both channels being retained in a single-joint volume. Experimental validation of our approach was conducted on a laboratory-based edge-illumination imaging system, where the use of two absorbing masks allows sensitivity to dark-field contrast in a single shot through an intensity drop arising from scattered X-rays filtered out by the detector mask. A significant advantage of our approach is the reduction of the problem dimensionality, particularly valuable for data-intensive applications like tomographic imaging. We demonstrated the efficacy of our method through using this hybrid contrast for tomography on two biological tissue samples, where the power of dark-field contrast to highlight sub-resolution features was retained with fast and dose-efficient data acquisition. We believe this is a powerful method for obtaining high-quality images while, at the same time, removing the necessity of acquiring multi-dimensional datasets for the extraction of dark-field contrast.

Supplemental information

Supplement 1. supplemental document.

Acknowledgment

The authors would like to acknowledge Francesco Iacoviello for support and access to the imaging facilities at the UCL Electrochemical Innovation Lab. AO is supported by the Royal Academy of Engineering.

Funding

Medical Research Council10.13039/501100000265 (CC0102); Cancer Research UK10.13039/501100000289 (CC0102); Royal Society10.13039/501100000288 (IEC\R2\192116); Wellcome Trust10.13039/100010269 (221367/Z/20/Z, CC0102); Royal Academy of Engineering10.13039/501100000287 (CiET1819/2/78); Engineering and Physical Sciences Research Council10.13039/501100000266 (EP/T02593X/1, EP/V035932/1, EP/T005408/1).

Disclosures

ME and AO declare a relevant patent: US granted US14/898281, Japan granted JP2016520736, and Europe granted EP 2014731991.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Supplemental document

See Supplement 1 (6.1MB, pdf) for supporting content.

REFERENCES

  • 1.Olivo A., “Edge-illumination x-ray phase-contrast imaging,” J. Phys.: Condens. Matter 33, 363002 (2021). 10.1088/1361-648X/ac0e6e [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Olivo A., Speller R., “A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources,” Appl. Phys. Lett. 91, 074106 (2007). 10.1063/1.2772193 [DOI] [Google Scholar]
  • 3.Zamir A., Endrizzi M., Hagen C. K., et al. , “Robust phase retrieval for high resolution edge illumination x-ray phase-contrast computed tomography in non-ideal environments,” Sci. Rep. 6, 31197 (2016). 10.1038/srep31197 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Munro P. R., Ignatyev K., Speller R. D., et al. , “Source size and temporal coherence requirements of coded aperture type x-ray phase contrast imaging systems,” Opt. Express 18, 19681–19692 (2010). 10.1364/OE.18.019681 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Doherty A., Massimi L., Olivo A., et al. , “Optimal and automated mask alignment for use in edge illumination x-ray differential-phase and dark-field imaging techniques,” Nucl. Instrum. Methods Phys. Res. A 984, 164602 (2020). 10.1016/j.nima.2020.164602 [DOI] [Google Scholar]
  • 6.Leatham T. A., Paganin D. M., Morgan K. S., “X-ray dark-field and phase retrieval without optics, via the Fokker–Planck equation,” IEEE Trans. Med. Imaging 42, 1681–1695 (2023). 10.1109/TMI.2023.3234901 [DOI] [PubMed] [Google Scholar]
  • 7.Rigon L., Arfelli F., Menk R.-H., “Generalized diffraction enhanced imaging to retrieve absorption, refraction and scattering effects,” J. Phys. D 40, 3077 (2007). 10.1088/0022-3727/40/10/011 [DOI] [Google Scholar]
  • 8.Pfeiffer F., Bech M., Bunk O., et al. , “Hard-x-ray dark-field imaging using a grating interferometer,” Nat. Mater. 7, 134–137 (2008). 10.1038/nmat2096 [DOI] [PubMed] [Google Scholar]
  • 9.Wang Z.-T., Kang K.-J., Huang Z.-F., et al. , “Quantitative grating-based x-ray dark-field computed tomography,” Appl. Phys. Lett. 95, 094105 (2009). 10.1063/1.3213557 [DOI] [Google Scholar]
  • 10.Bech M., Bunk O., Donath T., et al. , “Quantitative x-ray dark-field computed tomography,” Phys. Med. Biol. 55, 5529 (2010). 10.1088/0031-9155/55/18/017 [DOI] [PubMed] [Google Scholar]
  • 11.Berujon S., Wang H., Sawhney K., “X-ray multimodal imaging using a random-phase object,” Phys. Rev. A 86, 063813 (2012). 10.1103/PhysRevA.86.063813 [DOI] [Google Scholar]
  • 12.Wang H., Kashyap Y., Sawhney K., “From synchrotron radiation to lab source: advanced speckle-based x-ray imaging using abrasive paper,” Sci. Rep. 6, 20476 (2016). 10.1038/srep20476 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Pavlov K. M., Paganin D. M., Li H. T., et al. , “X-ray multi-modal intrinsic-speckle-tracking,” J. Opt. 22, 125604 (2020). 10.1088/2040-8986/abc313 [DOI] [Google Scholar]
  • 14.Alloo S. J., Morgan K. S., Paganin D. M., et al. , “Multimodal intrinsic speckle-tracking (mist) to extract images of rapidly-varying diffuse x-ray dark-field,” Sci. Rep. 13, 5424 (2023). 10.1038/s41598-023-31574-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Endrizzi M., Diemoz P. C., Millard T. P., et al. , “Hard x-ray dark-field imaging with incoherent sample illumination,” Appl. Phys. Lett. 104, 024106 (2014). 10.1063/1.4861855 [DOI] [Google Scholar]
  • 16.Kagias M., Wang Z., Villanueva-Perez P., et al. , “2d-omnidirectional hard-x-ray scattering sensitivity in a single shot,” Phys. Rev. Lett. 116, 093902 (2016). 10.1103/PhysRevLett.116.093902 [DOI] [PubMed] [Google Scholar]
  • 17.Zanette I., Zhou T., Burvall A., et al. , “Speckle-based x-ray phase-contrast and dark-field imaging with a laboratory source,” Phys. Rev. Lett. 112, 253903 (2014). 10.1103/PhysRevLett.112.253903 [DOI] [PubMed] [Google Scholar]
  • 18.Wen H., Bennett E. E., Hegedus M. M., et al. , “Fourier x-ray scattering radiography yields bone structural information,” Radiology 251, 910–918 (2009). 10.1148/radiol.2521081903 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Wen H. H., Bennett E. E., Kopace R., et al. , “Single-shot x-ray differential phase-contrast and diffraction imaging using two-dimensional transmission gratings,” Opt. Lett. 35, 1932–1934 (2010). 10.1364/OL.35.001932 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Vittoria F. A., Kallon G. K., Basta D., et al. , “Beam tracking approach for single–shot retrieval of absorption, refraction, and dark–field signals with laboratory x–ray sources,” Appl. Phys. Lett. 106, 224102 (2015). 10.1063/1.4922189 [DOI] [Google Scholar]
  • 21.Zdora M.-C., Thibault P., Zhou T., et al. , “X-ray phase-contrast imaging and metrology through unified modulated pattern analysis,” Phys. Rev. Lett. 118, 203903 (2017). 10.1103/PhysRevLett.118.203903 [DOI] [PubMed] [Google Scholar]
  • 22.Dreier E. S., Silvestre C., Kehres J., et al. , “Single-shot, omni-directional x-ray scattering imaging with a laboratory source and single-photon localization,” Opt. Lett. 45, 1021–1024 (2020). 10.1364/OL.381420 [DOI] [PubMed] [Google Scholar]
  • 23.Gustschin A., Riedel M., Taphorn K., et al. , “High-resolution and sensitivity bi-directional x-ray phase contrast imaging using 2d Talbot array illuminators,” Optica 8, 1588–1595 (2021). 10.1364/OPTICA.441004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Paganin D., Mayo S. C., Gureyev T. E., et al. , “Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object,” J. Microsc. 206, 33–40 (2002). 10.1046/j.1365-2818.2002.01010.x [DOI] [PubMed] [Google Scholar]
  • 25.Gureyev T., Paganin D., Arhatari B., et al. , “Dark-field signal extraction in propagation-based phase-contrast imaging,” Phys. Med. Biol. 65, 215029 (2020). 10.1088/1361-6560/abac9d [DOI] [PubMed] [Google Scholar]
  • 26.Beltran M. A., Paganin D. M., Croughan M. K., et al. , “Fast implicit diffusive dark-field retrieval for single-exposure, single-mask x-ray imaging,” Optica 10, 422–429 (2023). 10.1364/OPTICA.480489 [DOI] [Google Scholar]
  • 27.Havariyoun G., Vittoria F. A., Hagen C. K., et al. , “A compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast,” Phys. Med. Biol. 64, 235005 (2019). 10.1088/1361-6560/ab4912 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Buchanan I., Kallon G., Beckenbach T., et al. , “Effective modeling of high-energy laboratory-based x-ray phase contrast imaging utilizing absorption masks or gratings,” J. Appl. Phys. 128, 214503 (2020). 10.1063/5.0024475 [DOI] [Google Scholar]
  • 29.Partridge T., Astolfo A., Shankar S., et al. , “Enhanced detection of threat materials by dark-field x-ray imaging combined with deep neural networks,” Nat. Commun. 13, 4651 (2022). 10.1038/s41467-022-32402-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Astolfo A., Endrizzi M., Kallon G., et al. , “A first investigation of accuracy, precision and sensitivity of phase-based x-ray dark-field imaging,” J. Phys. D 49, 485501 (2016). 10.1088/0022-3727/49/48/485501 [DOI] [Google Scholar]
  • 31.Doherty A., Savvidis S., Navarrete-León C., et al. , “Edge-illumination x-ray dark-field tomography,” Phys. Rev. Appl. 19, 054042 (2023). 10.1103/PhysRevApplied.19.054042 [DOI] [Google Scholar]
  • 32.Massimi L., Suaris T., Hagen C. K., et al. , “Volumetric high-resolution x-ray phase-contrast virtual histology of breast specimens with a compact laboratory system,” IEEE Trans. Med. Imaging 41, 1188–1195 (2021). 10.1109/TMI.2021.3137964 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Zekavat A. R., Lioliou G., Morgó O. R. i., et al. , “Phase contrast micro-CT with adjustable in-slice spatial resolution at constant magnification,” Phys. Med. Biol. 69, 105017 (2024). 10.1088/1361-6560/ad4000 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Hagen C. K., Vittoria F. A., Morgó O. R. i., et al. , “Cycloidal computed tomography,” Phys. Rev. Appl. 14, 014069 (2020). 10.1103/PhysRevApplied.14.014069 [DOI] [Google Scholar]
  • 35.Brombal L., Arfelli F., Menk R. H., et al. , “Pepi lab: a flexible compact multi-modal setup for x-ray phase-contrast and spectral imaging,” Sci. Rep. 13, 4206 (2023). 10.1038/s41598-023-30316-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Buchanan I., Cipiccia S., Peiffer C., et al. , “Direct x-ray scattering signal measurements in edge-illumination/beam-tracking imaging and their interplay with the variance of the refraction signals,” Appl. Phys. Rev. 10, 041406 (2023). 10.1063/5.0168049 [DOI] [Google Scholar]
  • 37.Jensen T. H., Bech M., Zanette I., et al. , “Directional x-ray dark-field imaging of strongly ordered systems,” Phys. Rev. B 82, 214103 (2010). 10.1103/PhysRevB.82.214103 [DOI] [Google Scholar]
  • 38.Modregger P., Scattarella F., Pinzer B., et al. , “Imaging the ultrasmall-angle x-ray scattering distribution with grating interferometry,” Phys. Rev. Lett. 108, 048101 (2012). 10.1103/PhysRevLett.108.048101 [DOI] [PubMed] [Google Scholar]
  • 39.Graetz J., Balles A., Hanke R., et al. , “Review and experimental verification of x-ray dark-field signal interpretations with respect to quantitative isotropic and anisotropic dark-field computed tomography,” Phys. Med. Biol. 65, 235017 (2020). 10.1088/1361-6560/abb7c6 [DOI] [PubMed] [Google Scholar]
  • 40.Smith R., De Marco F., Broche L., et al. , “X-ray directional dark-field imaging using unified modulated pattern analysis,” Plos One 17, e0273315 (2022). 10.1371/journal.pone.0273315 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.How Y. Y., Morgan K. S., “Quantifying the x-ray dark-field signal in single-grid imaging,” Opt. Express 30, 10899–10918 (2022). 10.1364/OE.451834 [DOI] [PubMed] [Google Scholar]
  • 42.Croughan M. K., How Y. Y., Pennings A., et al. , “Directional dark-field retrieval with single-grid x-ray imaging,” Opt. Express 31, 11578–11597 (2023). 10.1364/OE.480031 [DOI] [PubMed] [Google Scholar]
  • 43.Lynch S. K., Pai V., Auxier J., et al. , “Interpretation of dark-field contrast and particle-size selectivity in grating interferometers,” Appl. Opt. 50, 4310–4319 (2011). 10.1364/AO.50.004310 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Vittoria F. A., Endrizzi M., Olivo A., “Retrieving the ultrasmall-angle x-ray scattering signal with polychromatic radiation in speckle-tracking and beam-tracking phase-contrast imaging,” Phys. Rev. Appl. 7, 034024 (2017). 10.1103/PhysRevApplied.7.034024 [DOI] [Google Scholar]
  • 45.Diemoz P. C., Vittoria F. A., Hagen C. K., et al. , “Single-image phase retrieval using an edge illumination x-ray phase-contrast imaging setup,” J. Synchrotron Radiat. 22, 1072–1077 (2015). 10.1107/S1600577515008978 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Endrizzi M., Vittoria F., Rigon L., et al. , “X-ray phase-contrast radiography and tomography with a multiaperture analyzer,” Phys. Rev. Lett. 118, 243902 (2017). 10.1103/PhysRevLett.118.243902 [DOI] [PubMed] [Google Scholar]
  • 47.Henke B. L., Gullikson E. M., Davis J. C., “X-ray interactions: photoabsorption, scattering, transmission, and reflection at e= 50-30,000 ev, z= 1-92,” At. Data Nucl. Data Tables 54, 181–342 (1993). 10.1006/adnd.1993.1013 [DOI] [Google Scholar]
  • 48.Massimi L., Partridge T., Astolfo A., et al. , “Optimization of multipoint phase retrieval in edge illumination x-ray imaging: A theoretical and experimental analysis,” Med. Phys. 48, 5884–5896 (2021). 10.1002/mp.15162 [DOI] [PubMed] [Google Scholar]
  • 49.Krumm M., Kasperl S., Franz M., “Reducing non-linear artifacts of multi-material objects in industrial 3d computed tomography,” Ndt&E Int. 41, 242–251 (2008). 10.1016/j.ndteint.2007.12.001 [DOI] [Google Scholar]
  • 50.Van Gompel G., Van Slambrouck K., Defrise M., et al. , “Iterative correction of beam hardening artifacts in CT,” Med. Phys. 38, S36–S49 (2011). 10.1118/1.3577758 [DOI] [PubMed] [Google Scholar]
  • 51.Burvall A., Lundström U., Takman P. A., et al. , “Phase retrieval in x-ray phase-contrast imaging suitable for tomography,” Opt. Express 19, 10359–10376 (2011). 10.1364/OE.19.010359 [DOI] [PubMed] [Google Scholar]
  • 52.Koebernick N., Daly K. R., Keyes S. D., et al. , “High-resolution synchrotron imaging shows that root hairs influence rhizosphere soil structure formation,” New Phytol. 216, 124–135 (2017). 10.1111/nph.14705 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Ning L., Mehta R., Cao C., et al. , “Embedded 3d bioprinting of gelatin methacryloyl-based constructs with highly tunable structural fidelity,” ACS Appl. Mater. Interfaces 12, 44563–44577 (2020). 10.1021/acsami.0c15078 [DOI] [PubMed] [Google Scholar]
  • 54.Ning Z., Jolly D. S., Li G., et al. , “Visualizing plating-induced cracking in lithium-anode solid-electrolyte cells,” Nat. Mater. 20, 1121–1129 (2021). 10.1038/s41563-021-00967-8 [DOI] [PubMed] [Google Scholar]
  • 55.Walsh C., Tafforeau P., Wagner W., et al. , “Imaging intact human organs with local resolution of cellular structures using hierarchical phase-contrast tomography,” Nat. Methods 18, 1532–1541 (2021). 10.1038/s41592-021-01317-x [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Zamir A., Diemoz P. C., Vittoria F. A., et al. , “Edge illumination x-ray phase tomography of multi-material samples using a single-image phase retrieval algorithm,” Opt. Express 25, 11984–11996 (2017). 10.1364/OE.25.011984 [DOI] [PubMed] [Google Scholar]
  • 57.Nelson B. J., Leng S., Koenig T., et al. , “Complementary use of x-ray dark-field and attenuation computed tomography in quantifying pulmonary fibrosis in a mouse model,” Proc. SPIE 12036, 253–263 (2022). 10.1117/12.2612877 [DOI] [Google Scholar]
  • 58.Savvidis S., Gerli M. F., Pellegrini M., et al. , “Monitoring tissue engineered constructs and protocols with laboratory-based x-ray phase contrast tomography,” Acta Biomater. 141, 290–299 (2022). 10.1016/j.actbio.2022.01.022 [DOI] [PubMed] [Google Scholar]
  • 59.Citro A., Moser P. T., Dugnani E., et al. , “Biofabrication of a vascularized islet organ for type 1 diabetes,” Biomaterials 199, 40–51 (2019). 10.1016/j.biomaterials.2019.01.035 [DOI] [PubMed] [Google Scholar]
  • 60.Citro A., Neroni A., Pignatelli C., et al. , “Directed self-assembly of a xenogeneic vascularized endocrine pancreas for type 1 diabetes,” Nat. Commun. 14, 878 (2023). 10.1038/s41467-023-36582-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Nieuwenhuizen R. P., Lidke K. A., Bates M., et al. , “Measuring image resolution in optical nanoscopy,” Nat. Methods 10, 557–562 (2013). 10.1038/nmeth.2448 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Yashiro W., Vagovič P., Momose A., “Effect of beam hardening on a visibility-contrast image obtained by x-ray grating interferometry,” Opt. Express 23, 23462–23471 (2015). 10.1364/OE.23.023462 [DOI] [PubMed] [Google Scholar]
  • 63.De Marco F., Andrejewski J., Urban T., et al. , “X-ray dark-field signal reduction due to hardening of the visibility spectrum,” IEEE Trans. Med. Imaging 43, 1422–1433 (2023). 10.1109/TMI.2023.3337994 [DOI] [PubMed] [Google Scholar]
  • 64.Tang R., Organista C., Romano L., et al. , “Pixel-wise beam-hardening correction for dark-field signal in x-ray dual-phase grating interferometry,” Opt. Express 31, 40450–40468 (2023). 10.1364/OE.499397 [DOI] [PubMed] [Google Scholar]
  • 65.Yashiro W., Terui Y., Kawabata K., et al. , “On the origin of visibility contrast in x-ray Talbot interferometry,” Opt. Express 18, 16890–16901 (2010). 10.1364/OE.18.016890 [DOI] [PubMed] [Google Scholar]
  • 66.Michel T., Rieger J., Anton G., et al. , “On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammography,” Phys. Med. Biol. 58, 2713 (2013). 10.1088/0031-9155/58/8/2713 [DOI] [PubMed] [Google Scholar]
  • 67.Modregger P., Kagias M., Irvine S. C., et al. , “Interpretation and utility of the moments of small-angle x-ray scattering distributions,” Phys. Rev. Lett. 118, 265501 (2017). 10.1103/PhysRevLett.118.265501 [DOI] [PubMed] [Google Scholar]
  • 68.Taphorn K., De Marco F., Andrejewski J., et al. , “Grating-based spectral x-ray dark-field imaging for correlation with structural size measures,” Sci. Rep. 10, 13195 (2020). 10.1038/s41598-020-70011-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Beltran M. A., Paganin D., Uesugi K., et al. , “2d and 3d x-ray phase retrieval of multi-material objects using a single defocus distance,” Opt. Express 18, 6423–6436 (2010). 10.1364/OE.18.006423 [DOI] [PubMed] [Google Scholar]
  • 70.Häggmark I., Vågberg W., Hertz H. M., et al. , “Comparison of quantitative multi-material phase-retrieval algorithms in propagation-based phase-contrast x-ray tomography,” Opt. Express 25, 33543–33558 (2017). 10.1364/OE.25.033543 [DOI] [Google Scholar]
  • 71.Wang Z., Clavijo C., Roessl E., et al. , “Image fusion scheme for differential phase contrast mammography,” J. Instrum. 8, C07011 (2013). 10.1088/1748-0221/8/07/C07011 [DOI] [Google Scholar]
  • 72.Scholkmann F., Revol V., Kaufmann R., et al. , “A new method for fusion, denoising and enhancement of x-ray images retrieved from Talbot–Lau grating interferometry,” Phys. Med. Biol. 59, 1425 (2014). 10.1088/0031-9155/59/6/1425 [DOI] [PubMed] [Google Scholar]
  • 73.Coello E., Sperl J. I., Bequé D., et al. , “Fourier domain image fusion for differential x-ray phase-contrast breast imaging,” Eur. J. Radiol. 89, 27–32 (2017). 10.1016/j.ejrad.2017.01.019 [DOI] [PubMed] [Google Scholar]
  • 74.Liu H., Liu M., Jiang X., et al. , “Multimodal image fusion for x-ray grating interferometry,” Sensors 23, 3115 (2023). 10.3390/s23063115 [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplement 1. supplemental document.

Data Availability Statement

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.


Articles from Optica are provided here courtesy of Optica Publishing Group

RESOURCES