Abstract
Objectives
This study aimed to evaluate the diagnostic utility of [68Ga]Ga-DOTA-Siglec-9 positron emission tomography-computed tomography (PET/CT) in assessing disease activity in a patient experiencing a relapse of giant cell arteritis (GCA).
Case presentation
A 90-year-old male patient with GCA, diagnosed in 2018, was enrolled. Demographic data, disease history, and laboratory parameters, including soluble VAP-1 (sVAP-1) levels, were recorded. The patient underwent a [68Ga]Ga-DOTA-Siglec-9 PET/CT scan. Additional imaging assessments included vascular ultrasound of the superficial temporal arteries, their branches, and the facial, axillary, subclavian, carotid, and vertebral arteries, along with magnetic resonance imaging (MRI) of the aorta.
The patient’s sVAP-1 level was 284 ng/ml compared to 123 ng/ml in the control group (SD ± 55). The [68Ga]Ga-DOTA-Siglec-9 PET/CT scan revealed increased tracer uptake (SUVmax) in the subclavian artery (2.5), aortic arch (2.9), and heart (2.9). Notably, the increased uptake in the descending aorta (3.5) abruptly diminished to 2.2 when passing the diaphragm, with no changes in vessel caliber observed in CT. The injection of [68Ga]Ga-DOTA-Siglec-9 was well tolerated. Aortic MRI revealed no signs of inflammatory involvement.
Conclusions
This study introduces the first application of [68Ga]Ga-DOTA-Siglec-9 PET/CT in a patient with GCA experiencing a relapse, revealing enhanced tracer uptake in the subclavian artery and aortic arch with a localized and abrupt reduction, absent in conventional imaging. These findings suggest that [68Ga]Ga-DOTA-Siglec-9 PET/CT has significant potential for precise, inflammation-specific detection of affected vascular tissue in GCA during relapse.
Keywords: giant cell arteritis, vasculitis, inflammation, imaging, biomarker, positron emission tomography-computed tomography
Introduction
Giant cell arteritis (GCA) is an immune-mediated vasculitis affecting large and medium-sized vessels. It can lead to vascular changes and occlusion due to severe vascular inflammation, neoangiogenesis, and remodeling. Vascular ultrasound of the temporal and axillary arteries has replaced temporal artery biopsy as the primary diagnostic tool for GCA in most centers (1, 2). However, ultrasound is limited in assessing the whole aorta, which is concerning given that up to 65% of GCA patients may exhibit aortic involvement (3, 4). Consequently, positron emission tomography-computed tomography (PET/CT) with [18F]fluordeoxyglucose (FDG) has become instrumental in diagnosing systemic manifestations of GCA (5). [18F]FDG-PET-CT may also aid in monitoring disease activity in GCA, as FDG uptake generally decreases with treatment (6, 7). However, interpreting follow-up scans is challenging due to increased glucose metabolism associated with vascular remodeling (6, 7). Persistent elevated FDG uptake, seen in up to 80% of patients, limits its specificity in detecting active inflammation (6–8). Similarly, persistence of disease-specific patterns of GCA complicate the use of CT (9) and magnetic resonance imaging (MRI) (10) in assessing current disease activity or detecting relapses in GCA.
The introduction of new, more inflammation-specific radiotracers, such as [68Ga]Ga-DOTA-Siglec-9, promises to improve the assessment of inflammatory vascular diseases. Early studies in animals and humans have demonstrated its safety, tolerability, and potential efficacy in identifying inflammation (11–13).
Sialic acid-binding immunoglobulin-like lectin-9 (Siglec-9) serves as a leukocyte ligand for vascular adhesion protein 1 (VAP-1) (11). VAP-1, a product of the amine oxidase copper-containing 3 gene, exists both as a soluble form (sVAP-1) with enzymatic activity and as a membrane-bound endothelial adhesion molecule (14). Under physiological conditions, VAP-1 resides in intracellular vesicles within various cell types, including endothelial cells. Upon inflammatory stimuli such as tumor necrosis factor-α, interferon-γ, and interleukin-1β, VAP-1 is mobilized to the endothelial cell surface, enabling its interaction with Siglec-9 on granulocytes and monocytes (12). This interaction triggers oxidative deamination, resulting in cytotoxic damage to endothelial cells and driving inflammatory response (14, 15). It promotes the synthesis of key endothelial adhesion molecules, including ICAM-1, Mad-CAM-1, E-selectin, and P-selectin. Additionally, the secretion of the chemokine CXCL8, activation of transcription factors such as NF-κB, and expression of matrix metalloproteinases are enhanced, facilitating leukocyte rolling, tethering, and migration (14).
The selective upregulation of VAP-1 during vascular inflammation renders [68Ga]Ga-DOTA-Siglec-9-PET/CT particularly promising for the assessment of GCA (16). In this study, we are the first to evaluate the diagnostic utility of [68Ga]Ga-DOTA-Siglec-9-PET/CT for assessing disease activity in a patient experiencing a GCA relapse.
Case description
Clinical and laboratory assessment
A 90-year-old male patient with GCA, initially diagnosed in August 2018 and fulfilling the American college of rheumatology (ACR)/European league against rheumatism (EULAR) classification criteria (2), was recruited at the Department of Rheumatology (University Hospital Bonn, Germany) in November 2023. He reported the recurrence of GCA symptoms, which included bitemporal headaches and night sweats. At the time of his scan, he was receiving 15 mg of methotrexate subcutaneously q1w and 2 mg of prednisolone q1d. His symptoms had re-emerged when the prednisolone dosage was reduced below 4 mg/day. Laboratory analysis revealed an elevated C-reactive protein (CRP) level at 21 mg/l and an erythrocyte sedimentation rate of 47 mm/hr and 81 mm/2hrs.
An enzyme-linked immunosorbent assay (ELISA) was performed to assess the sVAP-1 level (Human VAP-1 Quantikine ELISA Kit, R&D systems, Minneapolis, USA). For control, we analyzed the sVAP-1 levels of 15 healthy individuals. As samples generated values higher than the highest standard, we further diluted with calibrator diluent (1:200). The patient’s sVAP-1 level was 284 ng/ml, higher than the control group’s levels (mean 123 ng/ml, median 117 ng/ml, SD ± 55, min. 59 ng/ml, max. 241 ng/ml) ( Supplementary Figure 1 ).
[68Ga]Ga-DOTA-Siglec-9-PET/CT
Radiosynthesis of [68Ga]Ga-DOTA-Siglec-9 with 1.55 GBq gallium-68 revealed a decay corrected radiochemical yield of 95.1% (77.9% non-decay corrected radiochemical yield). A volume activity of 130.0 MBq/mL and an apparent molar activity of 21.0 MBq/nmol were obtained. Radiochemical purity was >98%. The patient underwent a [68Ga]Ga-DOTA-Siglec-9 PET-CT scan with an injection of 120 MBq [68Ga]Ga-DOTA-Siglec-9. Fifty-one minutes post-injection, we conducted a low-dose CT for attenuation correction and a whole-body PET scan (one minute/bed). The decision regarding the 51-minute post-injection delay was guided by prior research (13), from which we determined a minimum delay of 40 minutes post-injection. The protocol is available with the full text of this article online ( Figure 1 ).
[68Ga]Ga-DOTA-Siglec-9 PET scan revealed increased tracer uptake (SUVmax) in the subclavian artery (2.5), aortic arch (2.9), and heart (2.9), in contrast to an uptake of 1.5 in the liver ( Figure 2 ). Notably, an increased uptake in the descending aorta (3.5) abruptly diminished to (2.2) while passing the diaphragm but before reaching the cealic trunk (2 cm subdiaphragmatic), with only minimal changes in vessel caliber (29x30mm) and no intermediate branching vessels. The injection of [68Ga]Ga-DOTA-Siglec-9 was well tolerated.
Further imaging techniques
The patient underwent a comprehensive ultrasound examination of the common superficial temporal arteries with their frontal and parietal branches, as well as the facial, axillary, brachial, subclavian, and carotid arteries. The examination was conducted using a GE LOGIQ e10 (2021) ultrasound machine. Measurement of the highest intima-media thickness (IMT) of the arteries was conducted in B-mode at the point of greatest extent of the distal vessel and compared to established cut-off values (17). Outcome Measures in Rheumatology (OMERACT) ultrasound score for monitoring disease activity in GCA was calculated (18). Values were compared to vascular ultrasound results from the previous visit six weeks before.
The IMT measurements for the right axillary artery (1.23 mm), frontal branch (0.37 mm), and facial artery (0.46 mm) surpassed the established cut-off values (17) ( Figure 3 ), displaying no changes in the degree of vascular involvement compared to the results of the last visit (data not shown). No other arteries examined, exhibited pathological IMT (data not shown). The OMERACT ultrasound score registered at 0.95 at the time of the scan, showing a slight decrease from 1.0 recorded six weeks before.
Additionally, a comprehensive ophthalmological assessment was conducted, encompassing evaluations of best-corrected visual acuity, intraocular pressure, and optical coherence tomography (angiography). The findings for both eyes were consistent with normal age-related conditions, and ocular complications related to GCA were ruled out at the time of examination ( Supplementary Figure 2 ).
Moreover, MRI assessment of the aorta was conducted utilizing a 3-Tesla system (Ingenia 3.0T, Philips Healthcare, Best, The Netherlands). A 18-channel body array coil was employed for signal reception. The acquisition protocol included a coronary balanced gradient echo sequence, non-Cartesian axial T2 SPAIR, axial diffusion-weighted imaging (DWI) with b-value of 800 s/mm², and axial steady-state free precession. Aortal MRI revealed no signs of inflammatory involvement of GCA ( Supplementary Figure 3 ).
Discussion
This study aimed to evaluate the diagnostic utility of the radiotracer [68Ga]Ga-DOTA-Siglec-9 for the assessment of vascular inflammation in GCA relapse.
While vascular ultrasound can be valuable in monitoring the disease and detecting relapses (19, 20) typically showing a reduction in IMT over the course of the disease, a significant limitation is its inability to comprehensively assess the entire aorta. This limitation is critical given that aortitis can lead to dilation, aneurysm, or dissection. In contrast, [18F]FDG-PET/CT offers a comprehensive assessment of all major arteries involved. However, persistent elevated uptake due to vascular remodeling is frequently observed even in remission, with reported diagnostic sensitivity and specificity at 77% and 71%, respectively (8).
Our pioneering, exploratory case report represents the first application of [68Ga]Ga-DOTA-Siglec-9 PET/CT in the context of GCA relapse, revealing enhanced tracer uptake in the subclavian artery and aortic arch with a localized and abrupt reduction. Intriguingly, these findings were not mirrored in aortic MRI imaging, and neither vascular ultrasound nor ophthalmological evaluations identified any new pathological changes. This discrepancy highlights a substantial diagnostic gap, underscoring the limitations of current diagnostic strategies in accurately identifying GCA relapses.
This study introduces [68Ga]Ga-DOTA-Siglec-9-PET/CT as a novel imaging approach for the identification of inflammation in the vascular system during GCA relapse. The affinity for inflammatory processes, driven by VAP-1, offers a promising avenue to refine diagnostic protocols for evaluating GCA activity. Our data also confirm the safety and tolerability of [68Ga]Ga-DOTA-Siglec-9 imaging, aligning with prior research (12, 13). Notably, [68Ga]Ga-DOTA-Siglec-9-PET demonstrated a lower radiation dose compared to [18F]FDG-PET (approximately 3 mSv vs. up to 15 mSv), making it especially appealing for reducing radiation exposure (13).
The detection of an elevated sVAP-1 level in our GCA patient compared to healthy controls suggest its potential as a biomarker for GCA. Elevated sVAP-1 levels may reflect heightened disease activity, as previously shown by the correlation between sVAP-1 concentrations and membrane-bound VAP-1 activity (14). However, sVAP-1’s role in GCA pathogenesis requires further validation, including the influence of matrix metalloproteinases, which contribute to endothelial cleaving. In this context, larger studies are needed to improve generalizability.
In summary, our study suggests that [68Ga]Ga-DOTA-Siglec-9-PET/CT could complement established imaging techniques for assessing GCA disease activity, potentially addressing limitations of traditional diagnostics. By targeting VAP-1, this method may allow precise localization and evaluation of systemic vascular inflammation, potentially reducing reliance on inconclusive multimodal approaches and enhancing diagnostic strategies and therapeutic management in GCA.
Several limitations should be noted: the single-patient design of our case report restricts the generalizability of imaging and biomarker assessments. A comparative [18F]FDG-PET/CT scan could elucidate the specific advantages and limitations of [68Ga]Ga-DOTA-Siglec-9 in evaluating GCA. Additionally, assessing diagnostic utility in newly diagnosed patients would be insightful. Future studies should further aim to establish standardized imaging protocols and include larger patient cohorts to reinforce its diagnostic utility in GCA management.
Acknowledgments
We thank the BioBank Bonn of the Bonn University Medical Faculty and the University Hospital Bonn for storing the biomaterials used in this study.
Funding Statement
The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.
Data availability statement
The original contributions presented in the study are included in the article/ Supplementary Material . Further inquiries can be directed to the corresponding author.
Ethics statement
The study was conducted in accordance with the Declaration of Helsinki and received approval from the ethics committee of the University Hospital Bonn, Germany (reference number: 321/22). Written informed consent was obtained from the patient prior to inclusion. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study. Written informed consent was obtained from the individual(s) for the publication of any potentially identifiable images or data included in this article.
Author contributions
SP: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Validation, Visualization, Writing – original draft, Writing – review & editing. JK: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Validation, Visualization, Writing – original draft, Writing – review & editing. BSc: Data curation, Formal analysis, Investigation, Methodology, Validation, Visualization, Writing – review & editing. AK: Data curation, Formal analysis, Investigation, Methodology, Validation, Visualization, Writing – review & editing. CB: Data curation, Formal analysis, Investigation, Validation, Visualization, Writing – review & editing. LV: Data curation, Formal analysis, Investigation, Validation, Visualization, Writing – review & editing. BSa: Data curation, Formal analysis, Investigation, Validation, Visualization, Writing – review & editing. JD: Project administration, Resources, Supervision, Writing – review & editing. AW: Data curation, Formal analysis, Investigation, Validation, Writing – review & editing. ME: Conceptualization, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing. VS: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.
Generative AI statement
The author(s) declare that no Generative AI was used in the creation of this manuscript.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fimmu.2024.1501790/full#supplementary-material
References
- 1. Dejaco C, Ramiro S, Bond M, Bosch P, Ponte C, Mackie SL, et al. EULAR recommendations for the use of imaging in large vessel vasculitis in clinical practice: 2023 update. Ann Rheum Dis. (2023). doi: 10.1136/ard-2023-224543 [DOI] [Google Scholar]
- 2. Ponte C, Grayson PC, Robson JC, Suppiah R, Gribbons KB, Judge A, et al. 2022 American College of Rheumatology/EULAR classification criteria for giant cell arteritis. Ann Rheum Dis. (2022) 81:1647–53. doi: 10.1136/ard-2022-223480 [DOI] [Google Scholar]
- 3. Espitia O, Agard C. Aortite et complications aortiques de l’artérite à cellules géantes (maladie de Horton). Rev Med Interne. (2013) 34:412–20. doi: 10.1016/j.revmed.2013.02.026 [DOI] [Google Scholar]
- 4. Robson JC, Kiran A, Maskell J, Hutchings A, Arden N, Dasgupta B, et al. The relative risk of aortic aneurysm in patients with giant cell arteritis compared with the general population of the UK. Ann Rheum Dis. (2015) 74:129–35. doi: 10.1136/annrheumdis-2013-204113 [DOI] [Google Scholar]
- 5. Slart RH. FDG-PET/CT(A) imaging in large vessel vasculitis and polymyalgia rheumatica: joint procedural recommendation of the EANM, SNMMI, and the PET Interest Group (PIG), and endorsed by the ASNC. Eur J Nucl Med Mol Imaging. (2018) 45:1250–69. doi: 10.1007/s00259-018-3973-8 [DOI] [Google Scholar]
- 6. Grayson PC, Alehashemi S, Bagheri AA, Civelek AC, Cupps TR, Kaplan MJ, et al. 18 F-fluorodeoxyglucose-positron emission tomography as an imaging biomarker in a prospective, longitudinal cohort of patients with large vessel vasculitis. Arthritis Rheumatol. (2018) 70:439–49. doi: 10.1002/art.40379 [DOI] [Google Scholar]
- 7. de Boysson H, Aide N, Liozon E, Lambert M, Parienti J-J, Monteil J, et al. Repetitive 18F-FDG-PET/CT in patients with large-vessel giant-cell arteritis and controlled disease. Eur J Intern Med. (2017) 46:66–70. doi: 10.1016/j.ejim.2017.08.013 [DOI] [PubMed] [Google Scholar]
- 8. van der Geest KS, Treglia G, Glaudemans AW, Brouwer E, Sandovici M, Jamar F, et al. Diagnostic value of 18FFDG-PET/CT for treatment monitoring in large vessel vasculitis: a systematic review and meta-analysis. Eur J Nucl Med Mol Imaging. (2021) 48:3886–902. doi: 10.1007/s00259-021-05362-8 [DOI] [Google Scholar]
- 9. Prieto-González S, García-Martínez A, Tavera-Bahillo I, Hernández-Rodríguez J, Gutiérrez-Chacoff J, Alba MA, et al. Effect of glucocorticoid treatment on computed tomography angiography detected large-vessel inflammation in giant-cell arteritis. A prospective, longitudinal study. Med (Baltimore). (2015) 94:e486. doi: 10.1097/MD.0000000000000486 [DOI] [Google Scholar]
- 10. Reichenbach S, Adler S, Bonel H, Cullmann JL, Kuchen S, Bütikofer L, et al. Magnetic resonance angiography in giant cell arteritis: results of a randomized controlled trial of tocilizumab in giant cell arteritis. Rheumatol (Oxford). (2018) 57:982–6. doi: 10.1093/rheumatology/key015 [DOI] [Google Scholar]
- 11. Aalto K, Autio A, Kiss EA, Elima K, Nymalm Y, Veres TZ, et al. Siglec-9 is a novel leukocyte ligand for vascular adhesion protein-1 and can be used in PET imaging of inflammation and cancer. Blood. (2011) 118:3725–33. doi: 10.1182/blood-2010-09-311076 [DOI] [Google Scholar]
- 12. Virtanen H, Autio A, Siitonen R, Liljenbäck H, Saanijoki T, Lankinen P, et al. 68Ga-DOTA-Siglec-9–a new imaging tool to detect synovitis. Arthritis Res Ther. (2015) 17:308. doi: 10.1186/s13075-015-0826-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Viitanen R, Moisio O, Lankinen P, Li X-G, Koivumäki M, Suilamo S, et al. First-in-humans study of 68Ga-DOTA-siglec-9, a PET ligand targeting vascular adhesion protein 1. J Nucl Med. (2021) 62:577–83. doi: 10.2967/jnumed.120.250696 [DOI] [Google Scholar]
- 14. Salmi M, Jalkanen S. Vascular adhesion protein-1: A cell surface amine oxidase in translation. Antioxid Redox Signal. (2019) 30:314–32. doi: 10.1089/ars.2017.7418 [DOI] [Google Scholar]
- 15. Heuts DP, Gummadova JO, Pang J, Rigby SE, Scrutton NS. Reaction of vascular adhesion protein-1 (VAP-1) with primary amines: mechanistic insights from isotope effects and quantitative structure-activity relationships. J Biol Chem. (2011) 286:29584–93. doi: 10.1074/jbc.M111.232850 [DOI] [Google Scholar]
- 16. Petzinna SM, Bauer C-J, Schäfer VS. Vascular-adhesion protein 1 in giant cell arteritis and polymyalgia rheumatica. Front Med. (2024) 11:1448157. doi: 10.3389/fmed.2024.1448157 [DOI] [Google Scholar]
- 17. Schäfer VS, Juche A, Ramiro S, Krause A, Schmidt WA. Ultrasound cut-off values for intima-media thickness of temporal, facial and axillary arteries in giant cell arteritis. Rheumatol (Oxford). (2017) 56:1632. doi: 10.1093/rheumatology/kex289 [DOI] [Google Scholar]
- 18. Dejaco C, Ponte C, Monti S, Rozza D, Scirè CA, Terslev L, et al. The provisional OMERACT ultrasonography score for giant cell arteritis. Ann Rheum Dis. (2023) 82:556–64. doi: 10.1136/ard-2022-223367 [DOI] [Google Scholar]
- 19. Bosch P, Dejaco C, Schmidt WA, Schlüter KD, Pregartner G, Schäfer VS. Ultrasound for diagnosis and follow-up of chronic axillary vasculitis in patients with long-standing giant cell arteritis. Ther Adv Musculoskelet Dis. (2021) 13:1759720X21998505. doi: 10.1177/1759720X21998505 [DOI] [Google Scholar]
- 20. Ponte C, Monti S, Scirè CA, Delvino P, Khmelinskii N, Milanesi A, et al. Ultrasound halo sign as a potential monitoring tool for patients with giant cell arteritis: a prospective analysis. Ann Rheum Dis. (2021) 80:1475–82. doi: 10.1136/annrheumdis-2021-220306 [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The original contributions presented in the study are included in the article/ Supplementary Material . Further inquiries can be directed to the corresponding author.