Abstract
The guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements. To overcome this challenge, a guide catheter can be useful support enabling the deployment of stents in such challenging cases. We present the case of a 56-year-old male patient who was brought in by an ambulance with out-of-hospital ventricular fibrillation arrest (OOHVFA) and return of spontaneous circulation (ROSC) following successful resuscitation. The patient underwent emergency coronary angioplasty, which revealed extensive disease in the left coronary arteries and severe disease in the right coronary artery (RCA). Coronary angioplasty proved challenging secondary to vessel tortuosity, and a GEC was used for stent placement. Two stents were placed into the RCA in an overlapping fashion with the help of GEC to achieve thrombolysis in myocardial infarction (TIMI-3) flow. The patient was admitted to the intensive care unit (ICU), and echocardiography revealed mild-to-moderate left ventricular systolic dysfunction. The patient required significant inotropic support, and a computerised tomography (CT) scan of the brain showed severe hypoxic encephalopathy. The patient did not show any improvement and remained under intubation. The patient was extubated following a discussion with his family and palliative care team and passed away peacefully.
Keywords: acute st-elevation myocardial infarction, coronary angioplasty with stenting, deep coronary intubation, guide extension catheter, guide extension-facilitated ostial stenting (gest), primary pci, primary percutaneous coronary intervention (pci), right coronary artery (rca), severe coronary artery disease, tortuous coronary anatomy
Introduction
Primary coronary angioplasty (PCI) can be challenging in patients with calcific and tortuous vessels because of poor lesion compliance and difficulty in stent delivery [1]. Optimal stent delivery remains a significant challenge for patients undergoing coronary angioplasty [1]. Various techniques have been used to optimise stent delivery and implantation, such as vessel straightening using buddy and support wires, high-pressure dilatation to prepare vessels and increase catheter support during the procedure through deep intubation, use of guide extension catheters (GECs), and anchor balloon techniques [1]. de Man et al. reported a single-centre study based on a large cohort of patients who underwent PCI performed by senior operators with the aid of a 5 Fr compatible GuideLiner catheter (Vascular Solutions Inc., Minneapolis, MN, US) in a 6 Fr catheter system. The indications for using GuideLiner support during angioplasty in these patients included backup support during stent delivery in 41 cases, selective contrast injection in 20 cases, and improved catheter alignment in 20 cases [2]. The device success rate was 93% in this study, and no major complications were reported.
A major advantage of GEC is that it can be used to advance across the points of resistance or tortuosity in the proximal vessel, allowing delivery of a stent within the catheter directly to the mid or even distal vessel with little or no resistance [3,4]. Another key advantage of GECs is the selective contrast injection, as reported by de Man et al., that deep intubation achieved with GECs allows direct contrast delivery to the target lesion requiring a smaller amount of contrast, and greater opacification can be achieved. This is particularly important in patients with renal failure and opacification of the dual native and graft vessels [1,2]. Liao et al. conducted a single-centre study in patients undergoing complex coronary angioplasty and reported that 5-4 Fr Expressman GECs (APT, China) were superior to 5 Fr GECs [5]. Despite their usefulness, these catheters also have some limitations, including difficulty in advancing them and the potential risk of vessel injury associated with them [6,7]. It is worth mentioning that the shape and size of the GEC have an impact on the passive and active backup support function provided by it. The former is dependent on the physical characteristics of the GEC wall such as stiffness of the GEC and distal preformed shape, which allows the ability of the GEC to achieve coaxial alignment within the coronary ostium allowing it to rest for support on the opposite of the aorta or the aortic valve. The active support is achieved by operator-dependent techniques such as GEC manipulation for deep seating engagement or coaxial alignment, and the smaller catheters such as 5 and 6 Fr offer the greater advantage of allowing deeper intubation compared to larger catheters [8]. GEC allows operators greater capability to deliver stents and balloons by providing 5-15 cm extra depth beyond that of a traditional guide catheter. Herein, we present a case of complex PCI requiring the use of GECs for stent delivery to achieve optimal angiographic results.
Case presentation
A 56-year-old man with no medical history experienced a sudden collapse at home. Immediate bystander cardiopulmonary resuscitation (CPR) was commenced by his wife. The ambulance crew that attended the scene found him in ventricular fibrillation, and a total of 11 shocks were administered to achieve a sustained return of spontaneous circulation (ROSC). He received two doses of amiodarone and five doses of adrenaline according to the guidelines of the United Kingdom Resus Council. Immediate post-ROSC electrocardiogram (ECG) showed inferior ST-segment elevation, and the patient was transferred to our centre for primary percutaneous coronary intervention.
On arrival, the patient was intubated and had inferior ST-segment elevation. The patient was immediately transferred to the catheterisation laboratory for an emergency coronary angioplasty. The procedure was performed using a right radial approach. The left system had extensive disease of the left anterior descending and circumflex arteries. The right coronary artery (RCA) had severe disease, extending from the proximal to the middle part of the vessel. Owing to vessel tortuosity, guide extension was used to deliver the first stent in the middle part of the RCA. After stent optimisation, we proceeded with the placement of a second stent in an overlapping fashion with the first stent, covering the RCA ostium. To reduce the parallax to the degree possible, we used a modified spider view. Initial attempts to accurately position the stent in the RCA ostium were hampered by the excessive movement of the stent with respiration and cardiac motion. To reduce the effect of these two factors, we first used a guide extension to confirm the ostial position of the stent and subsequently deployed the stent in the optimal position. Intravascular imaging after stent deployment confirmed an accurate stent placement covering the ostium of the RCA (Videos 1-3).
The patient was intubated and admitted to the intensive care unit (ICU), requiring inotropic support. A computerised tomography (CT) scan of the brain 48 hours post-admission showed severe hypoxic brain encephalopathy (Figure 1). Echocardiography in the ICU showed mild left ventricular systolic dysfunction, with a left ventricular ejection fraction of 45%-50% and inferior wall hypokinesia (Videos 4, 5). The patient remained intubated and showed no significant improvement. The prognosis was deemed poor, and consultations were held with the family and palliative care teams. Unfortunately, the patient succumbed to this illness a few days after hospital admission.
Discussion
Optimal visualisation of the coronary ostium requires projections in which the ostium is depicted in an orthogonal view. In determining optimal projections, useful lessons can be drawn from the structural field. Accurate placement of a transcatheter aortic valve is aided by pre-procedurally determined optimal C-arm projections derived from a dedicated CT scan. These views were selected to avoid parallax when visualising the aortic valve orifice. In this process, the S-curve plays a central role. Introduced by Piazza et al., the S-curve was derived by applying mathematical formulas in an ECG-gated CT scan [8]. Every point on the S-curve corresponds to the angulations that produce an orthogonal view of the aortic valve. When the same principle is applied with a focus not on the aortic valve but on the coronary ostia, the respective S-curves can be calculated. The issue that arises is that the angulations derived by this method are, in a significant proportion of cases, impractical to achieve in the Cath lab. This is particularly true for the RCA, where the optimal angulations are in the range of LAO 64 and CAUD 51 [8,9].
Targoński et al.'s findings were similar to the optimal angulations for the right coronary ostium between LAO 60 and LAO 80 with slight cranial angulation [10]. The most practical solution to optimally visualise a coronary ostium without parallax is to align the catheter with the ostium and select a view that depicts the tip of the catheter as circular and the contour of its proximal part as a set of straight lines. Several techniques have been developed to determine the exact location of the coronary ostium. They can be divided into techniques that provide direct visualisation of the ostium and methods that indirectly determine the exact location of the coronary ostium [11,12]. Intravascular ultrasound (IVUS) has been used for the real-time imaging of the ostium.
Indirect methods to determine the location of the coronary ostium include the floating wire and floating snare techniques. A hybrid approach was also described using a floating wire technique, in which an IVUS probe was mounted [13]. On the other hand, the Szabo technique should be considered a separate approach to the ostial stenting challenge, as the stent is manipulated before entering the guide catheter so that the proximal stent edge can play the role of a proximal marker for the ostium location by placing a coronary wire through the proximal stent strut [14]. Although all of these techniques provide a way of determining the location of the coronary ostium, optimal stent placement also requires mitigation of the excessive movement of the equipment in the aorta-ostial area during the final stage of stent deployment. To address this, techniques with rapid pacing during stent deployment have been described. Therefore, it is beneficial to develop an approach by which both accurate identification of the coronary ostium and precise stent placement can be achieved. This paper describes a simple approach. The guide extension helps not only mitigate excessive movement but also via contrast injection to identify the location of the ostium. If the anatomy allows, the ostium can be identified with minimal or no parallax by ensuring the coaxial engagement of the guide extension with the circular appearance of its tip, as previously described. If the angulations required for optimal visualisation are impractical to achieve with C-arm rotation, the introduction of a floating wire through the guide extension can facilitate the location of the coronary ostium.
GECs have become the mainstay of coronary intervention by facilitating device delivery and are used in almost 18% of PCI cases [3,9]. GEC enables smooth equipment stents and balloon delivery in complex and tortuous lesions and improves the coaxial alignment and backup support of the guide catheter. It also allows selective contrast injections and can help to improve the optical coherence tomography imaging quality by ensuring adequate blood clearance [8]. GECs are not without risks, which include coronary dissection, air embolism, wire and pushrod wrapping, and ischaemia [9,15-17].
Conclusions
Stent positioning in the ostium of a coronary artery poses a challenge, as its accurate placement depends not only on optimal visualisation of the origin of the coronary artery but also on avoiding excessive movement during the final stage of deployment. Guide extension can be an option that addresses both these considerations to achieve accurate stent placement.
Acknowledgments
Zahid Khan and George Besis contributed equally to the work and should be considered co-first authors.
Disclosures
Human subjects: Consent for treatment and open access publication was obtained or waived by all participants in this study.
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Zahid Khan, George Besis, Luciano Candilio
Acquisition, analysis, or interpretation of data: Zahid Khan, George Besis, Luciano Candilio, Nay Thu Win, Muscab Soyan
Drafting of the manuscript: Zahid Khan, George Besis, Luciano Candilio, Nay Thu Win
Critical review of the manuscript for important intellectual content: Zahid Khan, George Besis, Luciano Candilio, Muscab Soyan
Supervision: Luciano Candilio
References
- 1.Guide catheter extensions: where are they taking us? Fraser DG, Mamas MA. EuroIntervention. 2012;8:299–301. doi: 10.4244/EIJV8I3A47. [DOI] [PubMed] [Google Scholar]
- 2.Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry. de Man FH, Tandjung K, Hartmann M, et al. EuroIntervention. 2012;8:336–344. doi: 10.4244/EIJV8I3A52. [DOI] [PubMed] [Google Scholar]
- 3.Successful use of the Heartrail III catheter as a stent delivery catheter following failure of conventional techniques. Mamas MA, Fath-Ordoubadi F, Fraser D. Catheter Cardiovasc Interv. 2008;71:358–363. doi: 10.1002/ccd.21395. [DOI] [PubMed] [Google Scholar]
- 4.Use of the Heartrail II catheter as a distal stent delivery device; an extended case series. Mamas MA, Eichhöfer J, Hendry C, et al. EuroIntervention. 2009;5:265–271. doi: 10.4244/eijv5i2a41. [DOI] [PubMed] [Google Scholar]
- 5.A novel tapered guide extension catheter facilitated successful completion of complex percutaneous coronary intervention. Liao J, Wu R, Ma Y, Zhang M, Chen Y, Yao K, Ge J. Eur J Med Res. 2023;28:101. doi: 10.1186/s40001-023-01067-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Guide extension catheter stepwise advancement facilitated by repeated distal balloon anchoring. Andreou C, Karalis I, Maniotis C, Jukema JW, Koutouzis M. Cardiovasc Revasc Med. 2017;18:66–69. doi: 10.1016/j.carrev.2016.07.010. [DOI] [PubMed] [Google Scholar]
- 7.Guidezilla™ guide extension catheter I for transradial coronary intervention. Lei X, Liang Q, Fang Y, et al. Front Cardiovasc Med. 2022;9:931373. doi: 10.3389/fcvm.2022.931373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Transcatheter aortic valve replacement and new conduction abnormalities/permanent pacemaker: can we achieve the intended implant depth? Piazza N, Lauzier P, Mylotte D. JACC Cardiovasc Interv. 2016;9:255–258. doi: 10.1016/j.jcin.2015.11.034. [DOI] [PubMed] [Google Scholar]
- 9.Guide extension catheters: review of technology and future directions. Chava R, Mekala SR, Kalavakunta JK, Fischell TA. https://pmc.ncbi.nlm.nih.gov/articles/PMC10718559/ Interv Cardiol (Lond) 2023;15:646–654. [PMC free article] [PubMed] [Google Scholar]
- 10.Optimal fluoroscopic viewing angles for stenting of the coronary aorto-ostial lesions. Targoński R, Meyer-Szary J, Baścik B, Szurowska E, Gąsecka A, Jagielak D, Jaguszewski MJ. Cardiol J. 2021;28:831–841. doi: 10.5603/CJ.a2021.0080. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.The influence of electrocardiogram-gated computed tomography reconstruction into 8 or 10 cardiac phases on cardiac-pulsatility-induced motion quantification of stent grafts in the aorta. Simmering JA, Zagers DA, Geelkerken RH, Kuipers H, Te Riet O G Scholten GA, Reijnen MM, Slump CH. JVS Vasc Sci. 2023;4:100131. doi: 10.1016/j.jvssci.2023.100131. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.A novel guide extension assisted stenting technique for coronary bifurcation lesions. Y-Hassan S, de Palma R. World J Cardiol. 2021;13:155–162. doi: 10.4330/wjc.v13.i6.155. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Deep intubation technique for complex percutaneous coronary intervention. Insights of a feared and harmless technique. Allende R, Barbeau G, Rodés-Cabau J. Scirea. 2021;5:31–44. [Google Scholar]
- 14.Szabo 2-stent technique for coronary bifurcation lesions: procedural and short-term outcomes. Yang H, Qian J, Huang Z, Ge J. BMC Cardiovasc Disord. 2020;20:325. doi: 10.1186/s12872-020-01605-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Treatment of ostial lesions using the Szabo technique: a case series. Applegate RJ, Davis JM, Leonard JC. Catheter Cardiovasc Interv. 2008;72:823–828. doi: 10.1002/ccd.21723. [DOI] [PubMed] [Google Scholar]
- 16.The use of a guide catheter extension system as an aid during transradial percutaneous coronary intervention of coronary artery bypass grafts. Farooq V, Mamas MA, Fath-Ordoubadi F, Fraser DG. Catheter Cardiovasc Interv. 2011;78:847–863. doi: 10.1002/ccd.22942. [DOI] [PubMed] [Google Scholar]
- 17.Adverse events associated with the use of guide extension catheters during percutaneous coronary intervention: reports from the Manufacturer and User Facility Device Experience (MAUDE) database. Chen Y, Shah AA, Shlofmitz E, et al. Cardiovasc Revasc Med. 2019;20:409–412. doi: 10.1016/j.carrev.2019.02.016. [DOI] [PubMed] [Google Scholar]