Introduction
Although cardiac output (CO) is a main actor in acute circulatory failure and its monitoring is recommended by international consensus in severe patients with shock who resist to initial treatment [1], not all intensivists do so. Why is it useful to measure CO in such patients? Why should one use devices that measure CO continuously, like transpulmonary thermodilution (TPTD) and the pulmonary artery catheter (PAC)? Although less used than before, PAC keeps an added value in selected indications [2], but what are these indications? In this position article, we provide some answers to these questions.
Knowing cardiac output is helpful when managing shock
CO is crucial for delivering oxygen to tissues, making it a key variable to monitor during shock. Measuring CO helps identify the type of shock. In hypovolemic and cardiogenic shock, CO is typically low, while CO tends to be elevated in septic shock, especially after initial fluid resuscitation [3]. The information beyond CO provided by PAC and TPTD, especially regarding cardiac preload or contractility, also helps characterizing the haemodynamic failure.
Measuring CO is essential for assessing the effectiveness of treatments like fluids and inotropes. Their therapeutic margin is low. In such a life-threatening condition, a rough estimate of their effectiveness is unreasonable. For instance, monitoring CO allows evaluation of the response to a fluid bolus and, in the case of unresponsiveness, discontinuation of fluid resuscitation. Similarly, clinicians cannot accurately assess inotropes efficacy without knowing their effect on CO.
Cardiac output should be directly measured
At the bedside, there is no way to perfectly measure CO. However, the worst estimate comes from surrogates, which seek to estimate CO and its changes by observing peripheral haemodynamic variables. For example, diuresis poorly correlates with changes in CO following volume expansion [4]. Changes in heart rate also unreliably assess fluid responsiveness, even for extreme changes [5].
More commonly, arterial pressure is used to judge the effects of volume expansion or inotropes on CO. However, it also depends on arterial resistance and compliance. Pulse pressure changes are poorly [5, 6] or not at all [7] correlated with fluid-induced changes in CO, even less when norepinephrine doses are modified [6]. Arterial pressure only is not enough for monitoring severe patients with circulatory failure.
Only dedicated devices allow real cardiac output monitoring
Echocardiography is essential for assessing cardiac function and structure and must be performed initially in shock patients (Fig. 1). However, it is usually performed only once or twice on the first day of treatment. Repeating it more often, i.e., at each haemodynamic assessment, for each preload responsiveness test, before and after each volume expansion or change in inotrope dose is time-consuming and hardly feasible.
Fig. 1.
Sequential haemodynamic assessment in patients with shock
Advanced techniques provide global haemodynamic evaluation
TPTD and PAC reliably estimate CO in most conditions, although they are not perfect. Less invasive devices are likely less reliable. For instance, uncalibrated pulse contour analysis fails to estimate CO when arterial resistance changes [8], especially under norepinephrine [9], though it may track CO changes during fluid infusion or tests of preload responsiveness.
The advantage of TPTD and PAC is that they offer more than just CO measurements. TPTD measures extravascular lung water and pulmonary vascular permeability, which guide fluid therapy, especially in acute respiratory distress syndrome (ARDS). They predict outcome [10] and lung water reflects diffuse alveolar damage [11]. TPTD estimates cardiac contractility [12] and measures CO continuously by calibrated pulse wave analysis, allowing an easy assessment of preload responsiveness [13, 14].
PAC remains a reliable tool that provides comprehensive haemodynamic information [15]. It provides the only reliable estimate of left atrial pressure [16]. It measures pulmonary vascular resistance and so is valuable in right heart failure and ARDS, for setting positive end-expiratory pressure, for instance [17]. PAC also assesses the true values of mixed venous oxygen saturation and carbon dioxide partial pressure [15], which are crucial for evaluating tissue wellness.
For a reasoned use of advanced haemodynamic monitoring tools
Haemodynamic monitoring cannot be based only on CO measurements and knowing CO in isolation is not enough for taking decisions. For instance, indices of fluid tolerance also influence the decision to give fluid. TPTD and PAC interestingly provide such variables in addition to CO. Also, the goal is to improve tissue perfusion and oxygenation, not CO. However, without knowing CO, indices of tissue perfusion and cell metabolism cannot be interpreted. For instance, if capillary refill time does not improve after volume expansion, it could mean that CO has not changed due to preload unresponsiveness, or that CO has increased but microcirculation remains impaired [18].
Due to their cost and invasiveness, TPTD and PAC should be reserved for the most severe cases of shock, particularly in patients with complex conditions like sepsis, cardiac dysfunction, ARDS, or intra-abdominal hypertension, when shock resists initial treatment with fluid and low-dose vasopressors (Fig. 1). In these patients, additional haemodynamic information provided by advanced monitoring are particularly helpful. Although many devices estimate and continuously measure CO, PAC and TPTD devices measure additional important haemodynamic variables often not available otherwise, which make these attractive if used in a logical and effective manner. Of course, the choice of which device to use depends on the clinical situation and the intensivist’s experience with each technique (Fig. 1).
There is an ongoing debate about whether using advanced monitoring techniques reduces mortality. While early studies failed to show a clear survival benefit, more recent research suggests that PAC may improve outcomes in patients with cardiogenic shock [19]. In septic shock, demonstrating a survival benefit is more challenging due to the complexity of constructing a treatment algorithm that works for all patients (20). However, future studies may show that strategies targeting specific haemodynamic variables—provided by advanced monitoring systems—can improve patient outcomes, especially if they use relevant endpoints other than mortality.
Conclusion
In the most severe and complex shock patients, efficient management requires a complete view of haemodynamic status, including CO. In our opinion, only TPTD and PAC reliably measure CO in such patients and provide sufficient haemodynamic information to guide their treatment.
Acknowledgements
None.
Author contributions
Drafting of the manuscript: D. DB, C.L. and X.M.
Funding
None.
Availability of data and materials
Not applicable.
Declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
X.M. is a member of the Medical Advisory Board of Pulsion Medical Systems (Getinge) and has received honoraria for lectures from Pulsion Medical Systems (Getinge), Baxter Healthcare and AOP. C.L. received honoraria for lectures from Sedana Medical. D.DB Edwards Lifesciences, Philips, Baxter, Viatris, Pharmazz.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40:1795–815. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.De Backer D, Hajjar LA, Pinsky MR. Is there still a place for the Swan-Ganz catheter? We are not sure. Intensive Care Med. 2018;44:960–2. [DOI] [PubMed] [Google Scholar]
- 3.Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2013;369:1726–34. [DOI] [PubMed] [Google Scholar]
- 4.Legrand M, Le Cam B, Perbet S, Roger C, Darmon M, Guerci P, et al. Urine sodium concentration to predict fluid responsiveness in oliguric ICU patients: a prospective multicenter observational study. Crit Care. 2016;20:165. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Ait-Hamou Z, Teboul JL, Anguel N, Monnet X. How to detect a positive response to a fluid bolus when cardiac output is not measured? Ann Intensive Care. 2019;9:138. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, et al. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine*. Crit Care Med. 2011;39:1394–9. [DOI] [PubMed] [Google Scholar]
- 7.Pierrakos C, Velissaris D, Scolletta S, Heenen S, De Backer D, Vincent JL. Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock? Intensive Care Med. 2012;38:422–8. [DOI] [PubMed] [Google Scholar]
- 8.Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg. 2008;106:1480–6. [DOI] [PubMed] [Google Scholar]
- 9.Cannesson M, Attof Y, Rosamel P, Joseph P, Bastien O, Lehot JJ. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol. 2007;24:832–9. [DOI] [PubMed] [Google Scholar]
- 10.Gavelli F, Shi R, Teboul JL, Azzolina D, Mercado P, Jozwiak M, et al. Extravascular lung water levels are associated with mortality: a systematic review and meta-analysis. Crit Care. 2022;26:202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Tagami T, Sawabe M, Kushimoto S, Marik PE, Mieno MN, Kawaguchi T, et al. Quantitative diagnosis of diffuse alveolar damage using extravascular lung water. Crit Care Med. 2013;41:2144–50. [DOI] [PubMed] [Google Scholar]
- 12.Jabot J, Monnet X, Lamia B, Chemla D, Richard C, Teboul JL. Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function. Crit Care Med. 2009;37:2913–8. [DOI] [PubMed] [Google Scholar]
- 13.Monnet X, Malbrain M, Pinsky MR. The prediction of fluid responsiveness. Intensive Care Med. 2023;49:83–6. [DOI] [PubMed] [Google Scholar]
- 14.Lai C, Shi R, Beurton A, Moretto F, Ayed S, Fage N, et al. The increase in cardiac output induced by a decrease in positive end-expiratory pressure reliably detects volume responsiveness: the PEEP-test study. Crit Care. 2023;27:136. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.De Backer D, Vincent JL. The pulmonary artery catheter: is it still alive? Curr Opin Crit Care. 2018;24:204–8. [DOI] [PubMed] [Google Scholar]
- 16.Mercado P, Maizel J, Marc J, Beyls C, Zerbib Y, Zogheib E, et al. Doppler echocardiographic indices are specific but not sensitive to predict pulmonary artery occlusion pressure in critically Ill patients under mechanical ventilation. Crit Care Med. 2021;49:e1–10. [DOI] [PubMed] [Google Scholar]
- 17.Cappio BS, Hagry J, Lai C, Rocca E, Fouque G, Rosalba D, et al. The effect of PEEP on Pulmonary vascular resistance depends on lung recruitability in ARDS patients. Am J Respir Crit Care Med. 2024. 10.1164/rccm.202402-0383OC. [DOI] [PubMed] [Google Scholar]
- 18.Fage N, Moretto F, Rosalba D, Shi R, Lai C, Teboul JL, et al. Effect on capillary refill time of volume expansion and increase of the norepinephrine dose in patients with septic shock. Crit Care. 2023;27:429. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Garan AR, Kanwar M, Thayer KL, Whitehead E, Zweck E, Hernandez-Montfort J, et al. Complete hemodynamic profiling with pulmonary artery catheters in cardiogenic shock is associated with lower in-hospital mortality. JACC Heart Fail. 2020;8:903–13. [DOI] [PubMed] [Google Scholar]
- 20.Pinsky MR, Cecconi M, Chew MS, De Backer D, Douglas I, Edwards M, et al. Effective hemodynamic monitoring. Crit Care. 2022;26:294. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.