Skip to main content

This is a preprint.

It has not yet been peer reviewed by a journal.

The National Library of Medicine is running a pilot to include preprints that result from research funded by NIH in PMC and PubMed.

ArXiv logoLink to ArXiv
[Preprint]. 2025 Apr 11:arXiv:2503.15711v2. Originally published 2025 Mar 19. [Version 2]

VPAL: A novel method to reduce reconstruction time for 5D free-running imaging

Yitong Yang, Muhammad Naeem, Marly Van Assen, Jerome Yerly, Davide Piccini, Matthias Stuber, John Oshinski, Matthias Chung
PMCID: PMC11957230  PMID: 40166739

Abstract

Purpose: Ferumoxytal-enhanced 5D free-running whole heart CMR provides image quality comparable to CTA, but requires hours-long reconstruction time, preventing clinical usage. This study developed a variable projection augmented Lagrangian (VPAL) method for 5D motion-resolved image reconstruction and compared it with alternating direction method of multipliers (ADMM) in five numerical simulations and 15 in-vivo pediatric data set. Approach: Relative error of the reconstructed images against the ground-truth images was assessed in numerical simulations. In-vivo analysis compared reconstruction time, mid-short axis (SA) blood-myocardium sharpness, left ventricular ejection fraction (LVEF), and a radiologist's image quality ratings between VPAL and ADMM. A paired t-test (p<0.05) was used to determine statistical significance, while linear regression and Bland-Altman analysis for agreement assessments. Results: VPAL and ADMM had similar relative errors compared to the ground truth, p = 0.07. In in-vivo datasets, VPAL reduced the reconstruction time from 16.3 +/- 3.6 hours (ADMM) to 4.7 +/- 1.1 hours (VPAL), p=1e-10. Blood-myocardium border sharpness in VPAL closely correlates to ADMM , R^2 = 0.97. The LVEFs values measured by VPAL and ADMM reconstructions are largely similar, 56 +/- 6 % in ADMM and 56 +/- 6 % in VPAL, p=0.55. Both VPAL and ADMM reconstructions have good to excellent diagnostic ratings (VPAL vs. ADMM: 3.9 +/- 0.3 vs. 3.8 +/- 0.4 in 2-chamber; 3.9 +/- 0.4 vs. 3.9 +/- in 4-chamber; 3.7 +/- 0.5 vs. 3.7 +/- 0.5 in mid-SA reformatted views. Conclusion: VPAL enables faster reconstruction than ADMM while maintaining equivalent image quality for functional assessments, supporting its potential for clinical use.

Full Text Availability

The license terms selected by the author(s) for this preprint version do not permit archiving in PMC. The full text is available from the preprint server.


Articles from ArXiv are provided here courtesy of arXiv

RESOURCES