Abstract
Anchorage control plays a crucial role in orthodontic treatment. When moving certain teeth into their desired position, it is essential to prevent any unintended movement of the teeth that are meant to remain in place. Temporary anchorage devices (TADs) are a significant advancement in modern orthodontics, providing a stable and reliable anchorage point for tooth movement. This review aims to discuss the types, clinical applications, benefits, and limitations of TADs, providing a comprehensive understanding of their role in contemporary orthodontic practice. The use of TADs enhances the precision and efficiency of orthodontic treatments, leading to faster results and improved patient comfort.
Keywords: anchorage, clinical application, orthodontics, site selection, temporary anchorage device, tooth movement, treatment planning
Introduction and background
Orthodontic treatment aims to correct malocclusions, improve dental function, and enhance facial aesthetics through precise tooth movement. The success of orthodontic treatment depends on anchorage control. Anchorage, which refers to the resistance against unwanted tooth movement, is essential in orthodontic treatment for addressing both dental and skeletal malocclusions. In the past, orthodontists have relied on various anchorage methods, such as intraoral appliances, extraoral headgear, and intermaxillary elastics. These traditional methods have been widely used but often come with limitations, such as patient compliance issues, the potential for unwanted movement of other teeth, and less precise control over the desired movement. Temporary anchorage devices (TADs) have revolutionized modern orthodontics by providing a reliable and efficient means for controlling tooth movement. Temporary anchorage devices (TADs) are commonly utilized in orthodontics to facilitate complex tooth movements that are challenging to achieve with traditional appliances, such as anterior/posterior intrusion, the en masse distalization of upper/lower arches, molar uprighting, and molar distalization. The success of microimplant anchorage relies on the design of the microscrew, the correct insertion site, and precise surgical technique. With these factors in place, clinicians can achieve complete anchorage control without relying on patient compliance [1].
Review
Materials and methods
The gathering of data for this narrative review was performed by conducting an electronic search for articles using the following databases: PubMed, Google Scholar, Science Direct, and Elton B. Stephens Company (EBSCO). The appropriate data were gathered using the search keywords temporary anchorage device, site selection, clinical application, anchorage, and tooth movement.
History
Gainsforth and Higley (1945) first published the use of subperiosteal Vitallium implant to retract maxillary canines in dogs [2]. In 1969, Linkow [3] described endosseous blade implants with perforation for orthodontic anchorage [4]. In 1983, Creekmore and Eklund reported the possibility of skeletal anchorage in orthodontics [5]. Roberts et al. (1990) used a traditional two-stage endosseous implant in the retromolar area to effectively reinforce anchorage while successfully closing the extraction site of the first molar in the mandible [6]. In 1994, Roberts et al. used an anchorage implant in the retromolar region about 5 mm distal to the mandibular third molar for the first half of space closure [7]. Turley et al. (1988) used endosseous implants in dogs as anchorage for the application of a variety of orthodontic and orthopedic forces [8]. In 1995, Block and Hoffman introduced the concept of using the palate as a location for anchorage devices with the creation of the onplant [9]. In 1997, Kanomi first reported the clinical use of mini-implants for orthodontic anchorage [10]. In 2002, Chung et al. introduced the C microimplant system [11]. Maino et al. (2003) introduced a spider screw system implant for skeletal anchorage [12]. Kyung et al. introduced another microimplant system called the "Absoanchor" (Figure 1) [13].
Figure 1. Figure depicting the evolution of implants in orthodontics with emphasis on key years and important milestones.
This figure was made using MS Word Document 2021 (Microsoft Corp., Redmond, WA) by Khyati S. Patel
Classification
There are eight types of classification based on different location, shape and size, composition, bone integration, use, configuration design, form, and surface structure [14-18]. The details about the classification are given in Table 1.
Table 1. Classification of temporary anchorage device.
This table was made using MS Word Document by Khyati S. Patel
Classification details | ||||
Based on location | Subperiosteal | Transosseous | Endosseous | - |
Based on shape and size | Conical (cylindrical) | Miniplate implants | Disimplants (onplants) | - |
Based on composition | Stainless steel | Cobalt-chromium-molybdenum | Titanium and ceramic implants | Miscellaneous |
Based on bone integration | Osseointegrated | Nonosseointegrated | - | - |
Based on use | Orthodontic implants | Prosthodontic implants | - | - |
Based on configuration design | Root form implants | Blade/plate implants | - | - |
Based on form | Solid | Hollow | Vented | - |
Based on surface structure | Threaded or nonthreaded | Porous or nonporous | - | - |
Types of anchorage
Miniscrew implants can offer two types of anchorage. Direct anchorage involves using an anchorage device that is firmly attached to the bone, establishing a stable and fixed reference point for managing tooth movement. Indirect anchorage, on the other hand, is a technique in which the anchorage device is not directly connected to the teeth that require movement but instead relies on other teeth or structures in the mouth for support [19].
Parts of orthodontic implants
The temporary anchorage device consists of three components: the head, neck, and body (screw) (Figure 2). First, the head is the top part of the implant where attachments or orthodontic appliances are connected. Then, the neck is the part that is present between the platform and head, which serves as the attachment site for various accessories such as an elastic NiTi coil spring or other orthodontic attachments. The body is the main portion of the implant, often threaded, which is inserted into the bone to provide stable anchorage [20,21].
Figure 2. Parts of the temporary anchorage device.
This figure was made using Canva (Canva Pty Ltd, Sydney, Australia) by Khyati S. Patel (https://www.canva.com/design/DAGiR50-6pU/SUPnNMgHhjA82k6OX9ZBtQ/edit?utm_content=DAGiR50-6pU&utm_campaign=designshare&utm_medium=link2&utm_source=sharebutton)
Head type classifications
There are different head types, which are characterized as small head, long head, circle head, fixation head, bracket head, and hook head. First, a small head is ideal for situations with limited spaces, as its compact size allows for easier placement. Second, a long head provides a larger surface area for force distribution, which helps improve stability and ensures more efficient and controlled tooth movement during orthodontic treatment. Third, a circle head offers versatility by allowing forces to be applied from various angles and providing greater flexibility in treatment and more control over tooth movement. Fourth, the fixation head helps secure auxiliary components and provides support for complex orthodontic treatments, ensuring stability and precise control during movements. Fifth, the bracket head enables the direct attachment of archwires, allowing for efficient force application and precise tooth movement. Lastly, the hook head offers attachment points for elastics or other auxiliary elements [20].
Miniscrew length and diameter
The size ranges are as follows: the length varies from 4 mm to 12 mm, while the diameter ranges from 1.2 mm to 2.7 mm. The commonly used miniscrew thickness is 1.5 mm. However, a thickness of 1.2 mm is used between the lower incisors due to the limited inter-radicular space [22-24]. In a study, larger-diameter (2.5 mm) monocortical screws provide increased anchorage force resistance compared with smaller-diameter (1.5 mm) monocortical screws in both the mandible and the maxilla. Smaller-diameter (1.5 mm) bicortical screws provide anchorage force resistance at least equal to larger-diameter (2.5 mm) monocortical screws [25].
Site consideration in the placement of TADs
Anatomical Structures at the Site of Placement
When placing TADs, there is a risk of perforating the roots of the adjacent teeth, nerves, blood vessels, bone, and sinuses in the area around the intended placement site. Careful planning and precision are crucial to avoid damaging these vulnerable structures [26].
Soft Tissue Characteristics
The quality of the soft tissue plays a crucial role in determining the success of anchorage provided by TADs. Ideally, TADs should be placed in attached gingiva as it is resistant to inflammation. The firm and attached gingiva is preferred over movable mucosa for better stability and tissue response [26].
Patient Comfort
Patients typically experience little to no pain after the routine placement of TADs. The procedure generally causes little to no discomfort, and if any pain does occur, it typically lasts no longer than a day or two [26].
Bone Characteristics
The integrity of temporary anchorage devices (TADs) is significantly influenced by the condition and amount of cortical bone. Bone thickness and density can vary not only between different anatomical sites in the same patient but also across different patients. The porous bone (D3 or D4) is present in the maxillary alveolar bone, and the denser bone (D2 and D3) is present in the mandibular alveolar bone (the Misch classification). The anterior regions generally have denser bones than the posterior areas. The maxillary cortical bone is thicker in the palate compared to the buccal surface. Specifically, the palatal cortical bone is consistently uniform, with a thickness of 4 mm or more apical to the cementoenamel junction (CEJ). Conversely, the cortical thickness of the mandibular buccal alveolar bone increases as it extends toward the ramus. The midpalatal region has a good-quality cortical bone with sufficient volume for TAD placement, and the retromolar pad area in the mandible also consists of dense cortical bone [9,10,27]. Factors influencing the precise placement of an orthodontic mini-implant are shown in Figure 3.
Figure 3. Factors influencing implant site selection.
This figure was made using MS PowerPoint Presentation (Microsoft Corp., Redmond, WA) by Khyati S. Patel
Inter-radicular sites for TAD placement
The appropriate sites for TAD insertion lie between the clinically invisible crestal bone margin and the clinically visible mucogingival border [28]. At least 3 mm of space between roots is generally considered necessary for the safe placement of TAD. A safety depth of at least 4 mm is required in the buccolingual direction to ensure sufficient space, as most monocortical TADs do not penetrate the opposite cortical bone [29]. The narrowest inter-radicular space should be greater than 3 mm. The thickness of the bone over the narrowest inter-radicular region must be adequate to support the length of the TAD [29]. Poggio et al. provided an anatomical map to assist in the safe placement of TADs between roots of the teeth [30].
Most commonly used sites in the maxilla
The most commonly used sites in the maxilla are as follows: the infrazygomatic region, zygomatic buttress; between the second premolar and the first permanent molar; between the first and second permanent molar buccally; between central incisors; the maxillary tuberosity region; palatal areas; and the midpalatal region [30,31].
Most common sites in the mandible
The most common sites in the mandible are as follows: between central incisors, between mandibular canine and premolar buccally, between the second premolar and the first permanent molar, between two permanent molars, the retromolar region, and the mandibular symphysis [30,31].
Extraradicular sites
Palatal Site for TAD Insertion
The anterior palate is an ideal site for TAD placement due to its high bone quality, thin soft tissue, and minimal risk of root damage or interference with the teeth. It enables the incorporation of larger TADs with increased stability [32,33]. The midsagittal and paramedian regions of the hard palate are good options for TAD placement, as they are easily accessible and covered by attached mucosa, providing excellent peri-implant conditions [34-36]. In the lateral and posterior areas of the palate, bone volume is reduced, limiting TAD placement to the median insertion in the posterior palate [37,38]. Proximity to structures such as incisor roots and incisive canals should be considered. Insertion directly into the palatal rugae can be difficult. Instead, the area just posterior to the palatal rugae, known as the "T-Zone," offers a more suitable location due to sufficient bone volume. As a general guideline, TADs should be placed posterior to the third palatal rugae within the T-Zone. Typically, at 3-4 mm distal to the incisive foramen and 3 mm around the palatal suture, the thickest vertical bone is present. Studies have shown a mean bone thickness of only 2.94 mm at the palatal suture. Therefore, TADs should be positioned 3-6 mm paramedian to the suture and 6-9 mm distal to the incisive foramen for optimal placement (Figure 4) [36,39].
Figure 4. Recommended insertion site posterior to the palatal rugae ("T-Zone").
The photograph was taken by Khyati S. Patel and edited using Canva (https://www.canva.com/design/DAGiVkgcEdI/mqSaTUC6evumQoUI7G0WIQ/edit?utm_content=DAGiVkgcEdI&utm_campaign=designshare&utm_medium=link2&utm_source=sharebutton)
Infrazygomatic Crest (IZC) Region for TAD Placement
The IZC region is a cortical bone pillar at the zygomatic process of the maxilla. It runs along a palpable bony ridge between the alveolar and zygomatic processes of the maxilla. The TAD placement site is typically located between the second premolar and first molar in younger patients, while in adults, it is positioned above the first molar. The ridge extends over 2 cm superiorly to the zygomatic-maxillary suture. TADs should be placed with approximately 1.5 mm of clearance from the soft tissue to the screw platform to avoid soft tissue irritation. The attached gingiva near the first molar is about 1 mm thick, with 1.1-1.3 mm cortical bone thickness. For soft tissue clearance and cortical bone engagement, IZC TADs generally penetrate the bone or sinus by 3.5-7.5 mm, with an 8 mm screw typically providing adequate stability. For optimal buccal bone engagement, TADs should be oriented at a 55°-70° angle inferior to the horizontal plane. The alveolar bone on the buccal surface of the second molar is preferred because it is a thicker bone. The IZC TAD sites are typically inferior to the anatomical zygomatic crest for clinical convenience, allowing for more stable placement and avoiding soft tissue interference (Figure 5) [40-42].
Figure 5. Location of the infrazygomatic crest.
The photograph was taken by Khyati S. Patel and edited using Canva (https://www.canva.com/design/DAGiV4rIYt0/GVuxBjiQ49eDNaiZhPgWyA/edit?utm_content=DAGiV4rIYt0&utm_campaign=designshare&utm_medium=link2&utm_source=sharebutton)
Maxillary Tuberosity for TAD Placement
The maxillary tuberosity is located at the lower part of the infratemporal surface of the maxilla. It is a rounded prominence, especially after the eruption of the wisdom tooth. The lateral side of the tuberosity is rough, articulating with the pyramidal process of the palatine bone and sometimes with the lateral pterygoid plate of the sphenoid. The posterior maxillary region typically consists of bone type III or IV, which is characterized by thin cortical bone and low-density trabecular bone. Bone height is often insufficient for implant placement due to the maxillary sinus. This makes achieving high primary stability more challenging. Although the bone quality is relatively poor (Misch D3 or D4 categories) at the maxillary tuberosity, the soft tissue is thin in this area, allowing the use of 6-7 mm-long TADs. A mini-implant with a diameter of 1.3-1.5 mm is recommended for areas with cancellous bone and low density, such as the maxillary tuberosity. TADs should be placed at an angulation of 20°-40° relative to the occlusal plane in a vertically directed manner (Figure 6) [43,44].
Figure 6. Orientation of the temporary anchorage device in the maxillary tuberosity region.
The photograph was taken by Khyati S. Patel and edited using Canva
Mandibular Buccal Shelf (MBS) Area
The MBS is situated bilaterally in the posterior portion of the mandibular body, located buccal to the roots of the first and second molars, and anterior to the oblique line of the mandibular ramus. The buccal bone, lateral to the distal root of the second molar, approximately 4 mm buccal to the cementoenamel junction (CEJ), is an optimal site for insertion. For specific biomechanical needs, insertion may also be considered lateral to the mesial root of the second molar, though it may require a more apical placement to achieve sufficient buccal bone thickness. Assessing the thickness of the cortical bone before insertion is essential. Predrilling may be required to enhance primary stability and minimize the risk of excessive torque and screw failure. The optimal angulation of the MBS for TAD insertion is approximately 38°, which should match the angulation of the TAD to align with the axial inclination of the molar (Figure 7) [45,46].
Figure 7. The location of the buccal shelf screw placement.
The photograph was taken by Khyati S. Patel and edited using Canva (https://www.canva.com/design/DAGiWL_A7j4/VTWvGeO90wvvVmQ1TVXEHQ/edit?utm_content=DAGiWL_A7j4&utm_campaign=designshare&utm_medium=link2&utm_source=sharebutton)
Ramus Area for TAD Placement
To address the limitations of traditional TADs (such as retromolar and inter-radicular) in managing horizontal impactions, Chang et al. developed a 2 mm-diameter stainless steel (SS) bone screw, suitable for dense cortical bone sites such as the mandibular buccal shelf (MBS) [46]. The MBS screw is placed lateral to the first and second molars, avoiding interference with horizontal impactions or the path of tooth movement within the alveolar process. The ramus of the mandible is quadrilateral in shape, with two surfaces, four borders, and two processes. The ideal site for TAD placement in the ramus is midway between the external and internal oblique ridges of the ascending ramus, approximately 5-8 mm above the occlusal plane, providing a direct line of traction without occlusal interference [47].
Retromolar Pad for TAD Placement
TADs are positioned in the area of the retromolar pad when a complete distal retraction of the mandibular dentition is intended. From an anatomical perspective, the retromolar pad is a triangular region defined medially by the temporal crest, laterally by the anterior border of the ramus, and posteriorly by the area near the third molar [48]. Also referred to as the piriformis papilla, the retromolar pad is a compressible elevation in the mucosa situated over the retromolar triangle, measuring approximately 11.2 mm in length and having a maximum transverse diameter of 7.9 mm. The best location for temporary anchorage devices (TADs) is slightly to the buccal side of the buccolingual midpoint of the retromolar triangle, creating a bull's-eye configuration. It is crucial to refrain from placing the TAD on the lingual side of the internal oblique ridge as this area contains a bony undercut and is situated near the lingual nerve and blood vessels. To identify the best spot for TAD placement, palpating the outer oblique ridge can assist the clinician in finding the ideal location [49].
Symphyseal Area for TAD Placement
TADs are placed in the symphysis area to secure fixed functional appliances in developing patients with skeletal Class II malocclusion, and they are also utilized for Class III elastics and the intrusion of mandibular incisors in individuals with a deep bite. The symphyseal area is an optimal site for screw placement because it has a thick cortical bone and is easily accessible. The upper outer surface of the symphysis may exhibit a subtle median ridge, indicating where the two halves of the fetal bone fused. Inferiorly, this ridge branches out to create a triangular mental protuberance, with the base being depressed and the sides elevated as mental tubercles. These characteristics form the chin. The mental foramen, through which the mental nerve and blood vessels pass, is situated beneath the space between the premolar teeth, usually near the second premolar [50]. Various sites for TAD placement are shown in Figure 8.
Figure 8. Sites for TAD placement.
This figure was made using BioRender (BioRender, Toronto, Canada) by Khyati S. Patel (https://BioRender.com)
TAD: temporary anchorage device
Indication
Temporary anchorage devices (TADs) are versatile tool in orthodontics, especially when traditional anchorage systems are insufficient. They can be utilized in numerous clinical scenarios, such as delivering absolute anchorage during maximum retraction, ideal for noncompliant patients. TADs prove particularly advantageous in adult orthodontic treatments, where they aid in complex tooth movements that may not be feasible with standard approaches.
They are effective in situations where the first molars are absent and can also assist in correcting deep bites, closing spaces left by extractions, and aligning tilted occlusal planes. TADs play an important role in correcting midline issues and addressing midline asymmetry or occlusal inclination. Moreover, they can assist in the alignment of impacted canines, as well as in the upright positioning and extrusion of impacted molars. TADs are beneficial for molar intrusion and support the distalization of maxillary molars and mandibular teeth. Additionally, they can be useful in managing vertical skeletal discrepancies, offering a broad array of solutions for difficult orthodontic cases [51,52].
Contraindications
Although there are no definitive contraindications for the insertion of orthodontic mini-implants, they are typically not advised for individuals with mental health disorders, significant systemic issues such as osteoporosis, blood-related conditions, or a background of substance abuse, including alcohol. Furthermore, candidates with inadequate bone quality or diabetes might not be the best fits for implant placement [51,52].
Insertion method
There are two types of miniscrew implants. Self-drilling miniscrews have uniquely engineered tips and cutting flutes that operate similarly to a corkscrew, enabling them to be directly inserted into the bone without requiring any predrilling. Non-self-drilling miniscrews require a pilot hole to be drilled before insertion. While this gives more control in denser bone, it adds complexity to the procedure and carries the risk of damaging nearby structures, such as nerves or tooth roots, if not done carefully [53-55]. An acrylic template or surgical guide is typically used to ensure the precise placement of the miniscrew and minimize the chances of error. The procedure is usually carried out under local anesthesia or infiltration, ensuring the patient remains comfortable throughout the process. The soft tissue at the planned insertion site is removed using a soft tissue punch, allowing for clear access to the bone. A drill bit that spins at a maximum of 1000 revolutions per minute (rpm) is used to create a pilot hole. The hole should be 2-3 mm deep and 0.3 mm smaller than the diameter of the miniscrew. The miniscrew is then placed using a specialized screwdriver, ensuring it is positioned at the correct angle and depth for stability. The choice between self-drilling and non-self-drilling screws largely depends on the bone's thickness and density [55,56].
Stability of implants
The stability of implants is a major concern, whether the implant relies on osseointegration or mechanical retention. It consists of two key types of stability. Primary stability, or initial stability, is achieved right after the insertion of an implant. It is a critical factor for the healing process and for determining when the implant can safely be loaded with functional forces. Secondary stability refers to the increased stability that occurs after implant placement as a result of bone regeneration and remodeling. Over time, the bone integrates with the implant, enhancing its stability and securing it more firmly in place [1,16].
Factors affecting success rate
The effectiveness of temporary anchorage devices (TADs) ranges from 80% to 100%, depending on various factors related to the device, patient, dentist, and implant location. Device-related factors include the risk of miniscrew fracture, which can occur due to a thin diameter or low strength; using a solid, conical screw design can help prevent this. Infection is another common cause of failure, and selecting screws with smooth transmucosal parts can reduce infection risks. Dentist-related factors include applying excessive pressure during insertion, which can fracture the cutting tip of self-drilling screws, and over-tightening the screw, which can lead to loosening. It is also important to apply stable, consistent forces during insertion to avoid loosening. Patient-related factors include the thickness of the cortical bone; if it is less than 0.5 mm, primary stability may not be achievable, and an alternative site may be necessary. Additionally, thick mucosa increases the distance between the point of force application and the screw's center of resistance (CRes), requiring the use of longer screws for proper stability. Addressing these factors during planning and placement can significantly improve the success rate of TADs [57-60].
Implant failures
Immediate Failures
Immediate failures occur right after the insertion of the miniscrew. Immediate failures in miniscrew placement can commonly result from choosing an incorrect insertion site, which leads to instability. Improper handling during the insertion process, such as wobbling the screw or altering the angle abruptly, may also result in failure. Placing the screw too soon after a tooth extraction is another contributing factor, as the recent extraction site may be unstable and affect the success of the screw. Thick overlying soft tissue or mucosa, including dense gum tissue, can hinder proper placement and compromise the screw's stability. Finally, the excessive tightening of the screw can cause it to fracture when it reaches the periosteum, the protective membrane around the bone, leading to failure [60].
Delayed Failures
Delayed failures can occur during orthodontic treatment, even if the initial placement was successful. These include excessive loading from elastic components, where too much force from elastic or other orthodontic devices can cause the screw to loosen. A sudden impact on the miniscrew head during chewing can also lead to failure, as biting or chewing places sudden pressure on the screw. Another issue is contact with the tooth root; if the screw comes into contact with the root surface, it can cause loosening or failure. Furthermore, excessive or insufficient bone remodeling can affect the screw's stability if the bone does not remodel properly around it. If a miniscrew fails, reinserting it into the same site often leads to repeated failure. In such cases, it is recommended to place the screw at an adjacent site. If the original location is essential, using a miniscrew with a wider diameter after 2-3 months can increase the chances of successful reinsertion [60].
Loading and anchorage consideration
Orthodontic miniscrews are subjected to loading immediately after placement; however, they are exposed to minimal forces only to ensure appropriate integration while reducing the likelihood of complications [23,61]. Liou et al. recommended ensuring a minimum of 2 mm distance between the implant and the roots of the adjacent teeth since implants can move as a result of orthodontic pressure [62]. Research has determined that mini-implants provide a reliable form of anchorage; however, they do not remain entirely immobile during the orthodontic loading phase. In certain patients, mini-implants may move in reaction to the applied orthodontic forces [63]. A study was carried out to assess the stability of miniscrew implants, taking into account the timing, amount, and site of force application. The findings endorse the notion that applying light forces (25-50 g) to miniscrew implants immediately can result in high success rates, facilitating meaningful and effective tooth movements. These results were unaffected by the magnitude of force or the site of its application [64].
Implant removal
The implant can be unscrewed using a screwdriver, with or without the application of topical or local anesthesia. If the implant cannot be removed, it is recommended to wait for 3-7 days, as the microfractures caused during the procedure may lead to the screw loosening over time [19].
Clinical applications
The mini-implant facilitated notable intrusion and alignment of the maxillary incisors, without depending on patient cooperation. This anchorage method was highly effective in significantly improving the patient's dental deep bite and gummy smile [65,66]. Miniscrews offer a reliable and minimally invasive solution for maxillary molar intrusion. For the intrusion of mandibular molars, miniplates are the favored option [67,68]. Miniscrew-supported distalizers are commonly placed in the anterior palate to treat Class II malocclusions [69-71]. When maxillary protraction is necessary, palatal miniscrews can serve as a substitute for miniplates; by using TADs, surgical intervention can be avoided in such cases [72,73]. In Class III correction, buccal shelf miniscrews are an effective option that requires less invasive surgery for placement compared to other anchorage methods [74-76]. Almost all intra-arch mechanics can be sufficiently supported by miniscrews positioned in inter-radicular spaces [77]. A summary of the clinical application of TADs is shown in Figure 9.
Figure 9. Clinical application of temporary anchorage device (TAD).
This figure was made using MS PowerPoint Presentation by Khyati S. Patel
Types of tooth movements
Controlled Tipping
The placement of short hooks should be positioned below the crest, with the line of force directed accordingly. To achieve extra labial crown torque and root repositioning, miniscrews may be positioned in the anterior region to provide the required torque for intrusion and root alignment [20,78].
Translation
In orthodontics, when using low-pull mechanics, a posterior open bite may develop. This can be addressed by applying box elastics to the posterior region. Additionally, some experts recommend using anterior bite planes to prevent the deepening of the anterior teeth. In high-pull mechanics, if the line of force passes above the center of resistance (CRes) of the dentition, it can cause a mesial drag on the molars without applying retraction force to the molar hook. To prevent this issue, a transpalatal arch (TPA) is frequently utilized. Furthermore, there is a possibility that an anterior open bite may develop, which can be addressed through the use of anterior box elastics. The symmetrical placement of temporary anchorage devices (TADs) during anterior retraction is an important biomechanical factor. If the implant is placed asymmetrically, the force vectors may cause a tilt of the occlusal plane. This situation should be prevented. Using a cantilever intrusion spring on the side of the lower implant can be a helpful method to prevent occlusal canting [20,78].
Molar Protraction
If the force is applied away from the center of resistance (CRes) of the molar, it will lead to rotation in all three dimensions. Mesial tipping can occur when a force is exerted through a labial hook. The placement of mini-implants at the apex can lead to posterior teeth intrusion, especially if the force vector has an intrusive element. The cant of the occlusal plane may result from unilateral intrusion, requiring control over both vertical and tipping forces. To reduce mesial tilting and intrusion, an SS wire can be used to maintain control. However, this may not always be effective for long-term protraction. The insertion of a lever arm into the auxiliary tube of the first molar aids in countering these forces [20,78].
Distalization of Molar
The tuberosity and the most posterior cortical bones of both the maxilla and mandible are limits for molar distalization. The extraction of third molars might be required, based on the amount of space and the potential for impaction. The distal force must be applied in three dimensions via the point of resistance of the molar for the initiation of movement. The second molars should be the primary targets for distalization since they are easier to manage in all three dimensions. The second molar's root surfaces are large and difficult to control, which can lead to rotation if force is not directed properly. Open coil springs are used to apply distal force to the molar, activated by a ligature attached to the temporary skeletal anchorage device (TSAD). Once molars are distalized, anterior and premolar retraction can be initiated using closed coil springs connected to the same TSAD. Distal vertical elastics help control any tipping of the molar during distalization. Over time, the TSAD may need to be repositioned as the second premolar roots get close to the screw [20,78].
Mesial Rotation
Since the protraction force is applied from the buccal side, there is a tendency for the molars to rotate mesially. To counteract this, the archwire should be contoured inward starting from the premolar region. Mesially angulated molars are a common issue in adult orthodontics. They can obstruct space for fixed bridges or implants, requiring uprighting to improve space for prosthetics [20,78].
Complications
During insertion, the placement of the miniscrew between the roots may harm the roots of the tooth and the periodontal ligament [79]. If the miniscrew does not adequately penetrate the cortical bone, it may shift beneath the mucosal tissue and along the periosteum. The risk of nerve injury is heightened when inserting miniscrews in specific locations, including the mandibular buccal surface, the maxillary palatal area, and the retromolar area [80,81]. Furthermore, air subcutaneous emphysema may develop if air becomes trapped beneath the skin in regions with loose alveolar tissue, especially within the zygomatic area, the posterior buccal region of the mandible, and the retromolar region. The placement of miniscrews close to the sinuses, such as in the maxillary incisal or posterior dentoalveolar regions, can result in sinus perforation, potentially harming the nasal or maxillary sinuses. Another issue to consider is miniscrew instability; applying excessive torsional forces during insertion can lead to bending, breakage, or microfractures in both the miniscrew and the adjacent bone, thus jeopardizing its stability. Complications can occur during orthodontic loading, such as anchorage failure that results from low bone density or the inadequate thickness of the cortical bone, which can impede the necessary support for maintaining appropriate forces throughout the treatment. There is also a risk of miniscrew migration, particularly when substantial orthodontic forces are applied if the anchorage is not completely secured. Soft tissue issues may arise, including the development of painful sores around the miniscrew, known as aphthous ulceration, as well as the overgrowth of soft tissue that could potentially obscure the miniscrew or its attachments, causing irritation and discomfort. Additionally, inflammation or infection in the soft tissues can lead to peri-implantitis. Complications that may arise during the extraction of the miniscrew include the possibility of the screw fracturing, which can make removal more challenging, and partial osseointegration, where a miniscrew that has somewhat fused with the bone may lead to difficulties and potential harm to the surrounding bone when being taken out. Careful planning and proper technique are crucial for minimizing these risks [82,83].
Recent advances
Recent advances in temporary anchorage devices (TADs) include bicortical microimplant and resorbable screw for orthodontic anchorage. A new bicortical microimplant with two anchorage units for applying forces bilaterally has been developed. The mesial displacement of the posterior teeth in beagle dogs, without rotation, was successfully accomplished using bilateral orthodontic forces. A resorbable implant would function as the anchorage unit and could be easily removed or naturally resorbed by the tissues. Absorbable screws are composed of a resorbable copolymer, which is a polyester derivative of L-lactic and glycolic acids. The poly-L-lactic acid/polyglycolic acid (PLA/PGA) copolymer degrades and resorbs in vivo through hydrolysis into L-lactic and glycolic acids, which are subsequently metabolized by the body. This material is nontoxic, nonirritating, and 100% amorphous, breaking down into carbon dioxide and water during metabolism. The potential advantages of bioresorbable implants include less stress shielding of the bone [84].
Conclusions
In conclusion, temporary anchorage devices (TADs) have become an indispensable tool in modern orthodontics, significantly enhancing the precision and efficiency of tooth movement. They expand the range of treatable cases, allowing for the correction of complex malocclusions that might be challenging or impossible with traditional methods alone. Although factors such as bone quality, insertion technique, and patient hygiene influence their effectiveness, the advantages of temporary anchorage devices (TADs), such as enhanced control, decreased dependence on the patient, and the possibility of more efficient and comfortable treatment, make them a significant tool in achieving the best orthodontic outcomes and creating beautiful, healthy smiles.
Disclosures
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Khyati S. Patel, Ishwa Parmar, Jaymin Parmar, Aafreen Quraishi, Kavya Patel, Uday Kumar Digumarthi, Manvi A. Arora, Bharvi Jani, Kinnari Shah, Alap Shah
Acquisition, analysis, or interpretation of data: Khyati S. Patel, Ishwa Parmar, Jaymin Parmar, Aafreen Quraishi, Kavya Patel, Uday Kumar Digumarthi, Manvi A. Arora, Bharvi Jani, Kinnari Shah, Alap Shah
Drafting of the manuscript: Khyati S. Patel, Ishwa Parmar, Jaymin Parmar, Aafreen Quraishi, Kavya Patel, Uday Kumar Digumarthi, Manvi A. Arora, Bharvi Jani, Kinnari Shah, Alap Shah
Critical review of the manuscript for important intellectual content: Khyati S. Patel, Ishwa Parmar, Jaymin Parmar, Aafreen Quraishi, Kavya Patel, Uday Kumar Digumarthi, Manvi A. Arora, Bharvi Jani, Kinnari Shah, Alap Shah
Supervision: Khyati S. Patel, Ishwa Parmar, Jaymin Parmar, Aafreen Quraishi, Kavya Patel, Uday Kumar Digumarthi, Manvi A. Arora, Bharvi Jani, Kinnari Shah, Alap Shah
References
- 1.Temporary anchorage devices in orthodontics - a brief review. Sanap MU, Karandikar A, Jatania A. https://www.jids.org.in/jan2019/4%20Dr.%20Madhumati.pdf J Interdiscip Dent Sci. 2019;8:10–14. [Google Scholar]
- 2.A study of orthodontic anchorage possibilities in basal bone. Gainsforth BL, Higley LB. Am J Orthod Oral Surg. 1945;31:406–417. [Google Scholar]
- 3.The endosseous blade implant and its use in orthodontics. Linkow LI. https://pubmed.ncbi.nlm.nih.gov/5264326/ Int J Orthod. 1969;7:149–154. [PubMed] [Google Scholar]
- 4.Implanto-orthodontics. Linkow LI. https://pubmed.ncbi.nlm.nih.gov/5278480/ J Clin Orthod. 1970;4:685–690. [PubMed] [Google Scholar]
- 5.The possibility of skeletal anchorage. Creekmore TD, Eklund MK. https://pubmed.ncbi.nlm.nih.gov/6574142/ J Clin Orthod. 1983;17:266–269. [PubMed] [Google Scholar]
- 6.Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Roberts WE, Marshall KJ, Mozsary PG. Angle Orthod. 1990;60:135–152. doi: 10.1043/0003-3219(1990)060<0135:REIUAA>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 7.Rigid implant anchorage to close a mandibular first molar extraction site. Roberts WE, Nelson CL, Goodacre CJ. https://pubmed.ncbi.nlm.nih.gov/8617822/ J Clin Orthod. 1994;28:693–704. [PubMed] [Google Scholar]
- 8.Orthodontic force application to titanium endosseous implants. Turley PK, Kean C, Schur J, Stefanac J, Gray J, Hennes J, Poon LC. Angle Orthod. 1988;58:151–162. doi: 10.1043/0003-3219(1988)058<0151:OFATTE>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 9.A new device for absolute anchorage for orthodontics. Block MS, Hoffman DR. Am J Orthod Dentofacial Orthop. 1995;107:251–258. doi: 10.1016/s0889-5406(95)70140-0. [DOI] [PubMed] [Google Scholar]
- 10.Mini-implant for orthodontic anchorage. Kanomi R. https://pubmed.ncbi.nlm.nih.gov/9511584/ J Clin Orthod. 1997;31:763–767. [PubMed] [Google Scholar]
- 11.The miniplate with tube for skeletal anchorage. Chung KR, Kim YS, Linton JL, Lee YJ. https://pubmed.ncbi.nlm.nih.gov/12165982/ J Clin Orthod. 2002;36:407–412. [PubMed] [Google Scholar]
- 12.The spider screw for skeletal anchorage. Maino BG, Bednar JO, Pagin P, Mura PA. https://www.jco-online.com/media/18187/jco_2003-02-90.pdf. J Clin Orthod. 2003;37:90–97. [PubMed] [Google Scholar]
- 13.Development of orthodontic micro-implants for intraoral anchorage. Kyung HM, Park HS, Bae SM, Sung JH, Kim IB. https://pubmed.ncbi.nlm.nih.gov/12866214/ J Clin Orthod. 2003;37:321–328. [PubMed] [Google Scholar]
- 14.Gandedkar NH, Vaid NR. MARPE: expanding the limits of orthodontics. Maringá, Brazil: Dental Press; 2022. Chapter 3: temporary anchorage devices (part II): evolution and overview of TAD applications in orthodontics; pp. 48–75. [Google Scholar]
- 15.Implants in orthodontics-a brief review. Bajaj R, Shenoy U, Banerjee S, Hazare A, Karia H, Atulkar M. https://d1wqtxts1xzle7.cloudfront.net/94147380/Implants_20in_20Orthodontics-_20A_20Brief_20Review-libre.pdf?1668330054=&response-content-disposition=inline%3B+filename%3DClassification_of_Implants_Use_of_Implan.pdf&Expires=1743418845&Signature=Hq5qoNyoiG7Cj4Xd6s75qwTaMAXD~23husOctiuWtrhvICeaR0EZK9wOPnGpAzcN8dVoVNTxbIJJxE6SEVdvFldXgsFTxcpuFsK6kVzLbG5s3jujXC7Jm74VsDURGyLIVNQY5TVjAoOWIYcy2mj9P1m3GvIEn~liD-cM3Ltpa9-pvXAVyqoZWa7w4u1JZQ~wYv1-ZNDqarY~b2NaEM6dAdM1z000FCiZCZ-eD3X7jvVac1kOwg9~FrQ2JWdmORaudxxSvid3GWbICgGIFI~HPYjAq~4eWbJTgBIWyD8FSGJ07vxh~zu~VGhqoYr4lm0VcWeCM2BvJiQaSExIMISJng__&Key-Pair-Id=APKAJLOHF5GGSLRBV4ZA Int J Oral Heal Med Res. 2017;3:92–97. [Google Scholar]
- 16.Temporary anchorage devices: a review. Kaul Y, Dhanani D, Choudhary A. https://core.ac.uk/download/pdf/233902952.pdf Int Healthc Res J. 2017;1:6–11. [Google Scholar]
- 17.Implants for orthodontic anchorage. Meta-analysis. Labanauskaite B, Jankauskas G, Vasiliauskas A, Haffar N. https://www.sbdmj.com/054/054-06.pdf. Stomatologija Baltic Dent Maxillofac J. 2005;7:128–132. [PubMed] [Google Scholar]
- 18.Temporary anchorage devices in orthodontics: a paradigm shift. Cope JB. Sem Orthod. 2005;11:3–9. [Google Scholar]
- 19.Miniscrew implants as temporary anchorage devices in orthodontics: a comprehensive review. Jasoria G, Shamim W, Rathore S, Kalra A, Manchanda M, Jaggi N. J Contemp Dent Pract. 2013;14:993–999. doi: 10.5005/jp-journals-10024-1439. [DOI] [PubMed] [Google Scholar]
- 20.Nanda R, Uribe F, Yadav S. Amsterdam, Netherlands: Elsevier; 2020. Temporary anchorage devices in orthodontics. [Google Scholar]
- 21.Enhancing orthodontic precision: a comprehensive review of temporary anchorage devices. Verma SK, Aiswareya G, Yadav PK, MP AA, Brij D. J Dent Panacea. 2024;6:92–102. [Google Scholar]
- 22.Miniscrew implants: the Aarhus anchorage system. Melsen B, Verna C. Sem Orthod. 2005;11:24–31. [Google Scholar]
- 23.Miniscrew implants: IMTEC mini ortho implants. Herman R, Cope JB. Sem Orthod. 2005;11:32–39. [Google Scholar]
- 24.Miniscrew implants: the spider screw anchorage system. Maino BG, Mura P, Bednar J. Sem Orthod. 2005;11:40–46. [Google Scholar]
- 25.Effect of screw diameter on orthodontic skeletal anchorage. Morarend C, Qian F, Marshall SD, et al. Am J Orthod Dentofacial Orthop. 2009;136:224–229. doi: 10.1016/j.ajodo.2007.07.031. [DOI] [PubMed] [Google Scholar]
- 26.Anatomic site consideration in placement of TADs: a literature review. Jain S, Kumari S, Chutia J, Sen S. https://cdronline.org/4.TAD%2023-31.pdf Chron Dent Res. 2022;11:23–31. [Google Scholar]
- 27.Miniscrew implant applications in contemporary orthodontics. Chang HP, Tseng YC. Kaohsiung J Med Sci. 2014;30:111–115. doi: 10.1016/j.kjms.2013.11.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Anatomical guidelines for miniscrew insertion: vestibular interradicular sites. Ludwig B, Glasl B, Kinzinger GS, Lietz T, Lisson JA. https://pubmed.ncbi.nlm.nih.gov/21785201/ J Clin Orthod. 2011;45:165–173. [PubMed] [Google Scholar]
- 29.Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement. Lee KJ, Joo E, Kim KD, Lee JS, Park YC, Yu HS. Am J Orthod Dentofacial Orthop. 2009;135:486–494. doi: 10.1016/j.ajodo.2007.05.019. [DOI] [PubMed] [Google Scholar]
- 30."Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Poggio PM, Incorvati C, Velo S, Carano A. Angle Orthod. 2006;76:191–197. doi: 10.1043/0003-3219(2006)076[0191:SZAGFM]2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 31.Romero‐Delmastro AA, Kadioglu O, Currier GF. Temporary anchorage devices in Clinical Orthodontics. Hoboken, NJ: John Wiley & Sons, Inc.; 2020. Considerations for the placement of TADs; pp. 83–89. [Google Scholar]
- 32.Protocols for combining the Beneslider with lingual appliances in class II treatment. Wilmes B, Neuschulz J, Safar M, Braumann B, Drescher D. https://www.uniklinik-duesseldorf.de/fileadmin/Fuer-Patienten-und-Besucher/Kliniken-Zentren-Institute/Kliniken/Poliklinik_fuer_Kieferorthopaedie/Kurse/Beneslider_lingual_JCO.pdf. J Clin Orthod. 2014;48:744–752. [PubMed] [Google Scholar]
- 33.Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Kang S, Lee SJ, Ahn SJ, Heo MS, Kim TW. Am J Orthod Dentofacial Orthop. 2007;131:0–81. doi: 10.1016/j.ajodo.2005.09.029. [DOI] [PubMed] [Google Scholar]
- 34.The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Wehrbein H, Merz BR, Diedrich P, Glatzmaier J. Clin Oral Implants Res. 1996;7:410–416. doi: 10.1034/j.1600-0501.1996.070416.x. [DOI] [PubMed] [Google Scholar]
- 35.Palatal bone support for orthodontic implant anchorage--a clinical and radiological study. Wehrbein H, Merz BR, Diedrich P. Eur J Orthod. 1999;21:65–70. doi: 10.1093/ejo/21.1.65. [DOI] [PubMed] [Google Scholar]
- 36.Alternative to the median region of the palate for placement of an orthodontic implant. Bernhart T, Vollgruber A, Gahleitner A, Dörtbudak O, Haas R. Clin Oral Implants Res. 2000;11:595–601. doi: 10.1034/j.1600-0501.2000.011006595.x. [DOI] [PubMed] [Google Scholar]
- 37.A three-dimensional digital insertion guide for palatal miniscrew placement. Maino BG, Paoletto E, Lombardo L, Siciliani G. https://adome.gr/cv/JCO-Maino.pdf. J Clin Orthod. 2016;50:12–22. [PubMed] [Google Scholar]
- 38.Three dimensional anatomical exploration of the anterior hard palate at the level of the third ruga for the placement of mini-implants--a cone-beam CT study. Hourfar J, Kanavakis G, Bister D, et al. Eur J Orthod. 2015;37:589–595. doi: 10.1093/ejo/cju093. [DOI] [PubMed] [Google Scholar]
- 39.Anatomical guidelines for miniscrew insertion: palatal sites. Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. https://www.jco-online.com/media/25099/jco_2011-08-433.pdf. J Clin Orthod. 2011;45:433–467. [PubMed] [Google Scholar]
- 40.Maxillary molar distalization with miniplates assessed on digital models: a prospective clinical trial. Cornelis MA, De Clerck HJ. Am J Orthod Dentofacial Orthop. 2007;132:373–377. doi: 10.1016/j.ajodo.2007.04.031. [DOI] [PubMed] [Google Scholar]
- 41.Assessment of infrazygomatic bone depth for mini-screw insertion. Baumgaertel S, Hans MG. Clin Oral Implants Res. 2009;20:638–642. doi: 10.1111/j.1600-0501.2008.01691.x. [DOI] [PubMed] [Google Scholar]
- 42.A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion. Liou EJ, Chen PH, Wang YC, Lin JC. Am J Orthod Dentofacial Orthop. 2007;131:352–356. doi: 10.1016/j.ajodo.2005.04.044. [DOI] [PubMed] [Google Scholar]
- 43.Soft-tissue and cortical-bone thickness at orthodontic implant sites. Kim HJ, Yun HS, Park HD, Kim DH, Park YC. Am J Orthod Dentofacial Orthop. 2006;130:177–182. doi: 10.1016/j.ajodo.2004.12.024. [DOI] [PubMed] [Google Scholar]
- 44.Skeletal anchorage using mini-implants in the maxillary tuberosity region. Venkateswaran S, George AM, Anand MK, Devi VS, Vora SR, Krishnaswamy NR. J Indian Orthod Soc. 2013;47:217–224. [Google Scholar]
- 45.Bone and cortical bone thickness of mandibular buccal shelf for mini-screw insertion in adults. Nucera R, Lo Giudice A, Bellocchio AM, et al. Angle Orthod. 2017;87:745–751. doi: 10.2319/011117-34.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Primary failure rate for 1680 extra-alveolar mandibular buccal shelf mini-screws placed in movable mucosa or attached gingiva. Chang C, Liu SS, Roberts WE. Angle Orthod. 2015;85:905–910. doi: 10.2319/092714.695.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Yu HS. Temporary anchorage devices in clinical orthodontics. Hoboken, NJ: John Wiley & Sons, Inc.; 2020. Understanding implant sites for TADs; pp. 91–98. [Google Scholar]
- 48.Surg Radiol Anat. Vol. 43. Cham, Switzerland: Springer; 2019. Anatomical variations in clinical dentistry; pp. 1259–1272. [Google Scholar]
- 49.Paik CH, Park IK, Woo YJ, Kim TW. Maryland Heights, MO: Mosby; 2009. Orthodontic miniscrew implants. [Google Scholar]
- 50.Skeletal anchorage in orthodontic treatment of class II malocclusion: contemporary applications of orthodontic implants, miniscrew implants and mini plates. Papadopoulos MA. J Indian Orthod Soc. 2015;49:52. [Google Scholar]
- 51.TADs in orthodontics. Shetty SK, Vincent S, Y MK, Madhur VK. Sch J Dent Sci. 2021;16:234–238. [Google Scholar]
- 52.Risk factors and indications of orthodontic temporary anchorage devices: a literature review. Hoste S, Vercruyssen M, Quirynen M, Willems G. Aust Orthod J. 2008;24:140–148. [PubMed] [Google Scholar]
- 53.Clinical applications of drill free screws in maxillofacial surgery. Heidemann W, Gerlach KL. J Cranio-Maxillofac Surg. 1999;27:252–255. doi: 10.1016/s1010-5182(99)80037-7. [DOI] [PubMed] [Google Scholar]
- 54.Drill free screws: a new form of osteosynthesis screw. Heidemann W, Gerlach KL, Gröbel KH, Köllner HG. J Craniomaxillofac Surg. 1998;26:163–168. doi: 10.1016/s1010-5182(98)80007-3. [DOI] [PubMed] [Google Scholar]
- 55.Orthodontic anchorage system using a locking plate and self-drilling screws. Hibi H, Ueda M, Sakai M, Ikemori Y. J Oral Maxillofac Surg. 2006;64:1173–1175. doi: 10.1016/j.joms.2006.03.044. [DOI] [PubMed] [Google Scholar]
- 56.An adjustable surgical guide for miniscrew placement. Suzuki EY, Buranastidporn B. https://pubmed.ncbi.nlm.nih.gov/16244426/ J Clin Orthod. 2005;39:588–590. [PubMed] [Google Scholar]
- 57.Factors affecting the clinical success of orthodontic anchorage: Experience with 266 temporary anchorage devices. Lai TT, Chen MH. J Dent Sci. 2014;9:49–55. [Google Scholar]
- 58.Factors affecting the clinical success of screw implants used as orthodontic anchorage. Park HS, Jeong SH, Kwon OW. Am J Orthod Dentofacial Orthop. 2006;130:18–25. doi: 10.1016/j.ajodo.2004.11.032. [DOI] [PubMed] [Google Scholar]
- 59.Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region. Moon CH, Lee DG, Lee HS, Im JS, Baek SH. Angle Orthod. 2008;78:101–106. doi: 10.2319/121706-515.1. [DOI] [PubMed] [Google Scholar]
- 60.Micro implants for orthodontic anchorage: a review of complications and management. Abraham ST, Paul MM. J Dent Implants. 2013;3:165–167. [Google Scholar]
- 61.Immediate loading of implants used for orthodontic anchorage. Melsen B, Costa A. Clin Orthod Res. 2000;3:23–28. doi: 10.1034/j.1600-0544.2000.030105.x. [DOI] [PubMed] [Google Scholar]
- 62.Do miniscrews remain stationary under orthodontic forces? Liou EJ, Pai BC, Lin JC. Am J Orthod Dentofacial Orthop. 2004;126:42–47. doi: 10.1016/j.ajodo.2003.06.018. [DOI] [PubMed] [Google Scholar]
- 63.Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Am J Orthod Dentofacial Orthop. 2003;124:373–378. doi: 10.1016/s0889-5406(03)00565-1. [DOI] [PubMed] [Google Scholar]
- 64.Experimental evaluation of tooth movement in the beagle dog with the mini-screw implant for orthodontic anchorage. Owens SE, Buschang PH, Cope JB, Franco PF, Rossouw PE. Am J Orthod Dentofacial Orthop. 2007;132:639–646. doi: 10.1016/j.ajodo.2005.07.034. [DOI] [PubMed] [Google Scholar]
- 65.A mini-implant for orthodontic anchorage in a deep overbite case. Ohnishi H, Yagi T, Yasuda Y, Takada K. Angle Orthod. 2005;75:444–452. doi: 10.1043/0003-3219(2005)75[444:AMFOAI]2.0.CO;2. [DOI] [PubMed] [Google Scholar]
- 66.The skeletodental adaptations in deep bite correction. McDowell EH, Baker IM. Am J Orthod Dentofacial Orthop. 1991;100:370–375. doi: 10.1016/0889-5406(91)70076-9. [DOI] [PubMed] [Google Scholar]
- 67.Skeletal anchorage system for open-bite correction. Umemori M, Sugawara J, Mitani H, Nagasaka H, Kawamura H. Am J Orthod Dentofacial Orthop. 1999;115:166–174. doi: 10.1016/S0889-5406(99)70345-8. [DOI] [PubMed] [Google Scholar]
- 68.The short-term skeleto-dental effects of a new spring for the intrusion of maxillary posterior teeth in open bite patients. Foot R, Dalci O, Gonzales C, Tarraf NE, Darendeliler MA. Prog Orthod. 2014;15:56. doi: 10.1186/s40510-014-0056-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Adult class II division 1 patient with severe gummy smile treated with temporary anchorage devices. Shu R, Huang L, Bai D. Am J Orthod Dentofacial Orthop. 2011;140:97–105. doi: 10.1016/j.ajodo.2011.01.021. [DOI] [PubMed] [Google Scholar]
- 70.Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing class II division 2 patient. Kim TW, Kim H, Lee SJ. Am J Orthod Dentofacial Orthop. 2006;130:676–685. doi: 10.1016/j.ajodo.2005.07.013. [DOI] [PubMed] [Google Scholar]
- 71.Conservative treatment of class II treatment with extraalveolar TADs. Nucă C, Marinescu AC, Caraine A, Buștiuc SG. https://journal.adre.ro/wp-content/uploads/2024/12/CONSERVATIVE-TREATMENT-OF-CLASS-II-TREATMENT-WITH-EXTRAALVEOLAR-TADs.pdf Rom J Med Dent Educ. 2024;13:13–19. [Google Scholar]
- 72.Comparative evaluation of maxillary protraction with or without skeletal anchorage. Sar C, Arman-Özçırpıcı A, Uçkan S, Yazıcı AC. Am J Orthod Dentofacial Orthop. 2011;139:636–649. doi: 10.1016/j.ajodo.2009.06.039. [DOI] [PubMed] [Google Scholar]
- 73.Maxillary protraction using a hybrid hyrax-facemask combination. Nienkemper M, Wilmes B, Pauls A, Drescher D. Prog Orthod. 2013;14:5. doi: 10.1186/2196-1042-14-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74.Comparative evaluation of treatment outcomes between temporary anchorage devices and class III elastics in class III malocclusions. Nakamura M, Kawanabe N, Kataoka T, Murakami T, Yamashiro T, Kamioka H. Am J Orthod Dentofacial Orthop. 2017;151:1116–1124. doi: 10.1016/j.ajodo.2016.10.040. [DOI] [PubMed] [Google Scholar]
- 75.Application of temporary anchorage devices for the treatment of adult class III malocclusions. Kuroda S, Tanaka E. Sem Orthod. 2011;17:91–97. [Google Scholar]
- 76.The Hybrid Hyrax Distalizer, a new all-in-one appliance for rapid palatal expansion, early class III treatment and upper molar distalization. Wilmes B, Ludwig B, Katyal V, Nienkemper M, Rein A, Drescher D. J Orthod. 2014;41:0–53. doi: 10.1179/1465313314Y.0000000107. [DOI] [PubMed] [Google Scholar]
- 77.Maxillary space closure using aligners and palatal mini-implants in patients with congenitally missing lateral incisors. Wilmes B, Schwarze J, Vasudavan S, Drescher D. https://ortholine.nl/wp-content/uploads/2022/11/Mesialslider-Aligner-JCO.pdf. J Clin Orthod. 2021;55:20–33. [PubMed] [Google Scholar]
- 78.Hoboken, NJ: John Wiley & Sons, Inc.; 2020. Temporary anchorage devices in clinical orthodontics. [Google Scholar]
- 79.Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment. Kadioglu O, Büyükyilmaz T, Zachrisson BU, Maino BG. Am J Orthod Dentofacial Orthop. 2008;134:353–360. doi: 10.1016/j.ajodo.2006.09.069. [DOI] [PubMed] [Google Scholar]
- 80.Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Papageorgiou SN, Zogakis IP, Papadopoulos MA. Am J Orthod Dentofacial Orthop. 2012;142:577–595. doi: 10.1016/j.ajodo.2012.05.016. [DOI] [PubMed] [Google Scholar]
- 81.Complications encountered in temporary orthodontic anchorage device therapy. Roncone CE. Sem Orthod. 2011;17:168–179. [Google Scholar]
- 82.Root repair after injury from mini-screw. Asscherickx K, Vannet BV, Wehrbein H, Sabzevar MM. Clin Oral Implants Res. 2005;16:575–578. doi: 10.1111/j.1600-0501.2005.01146.x. [DOI] [PubMed] [Google Scholar]
- 83.Complications using intermaxillary fixation screws. Hashemi HM, Parhiz A. J Oral Maxillofac Surg. 2011;69:1411–1414. doi: 10.1016/j.joms.2010.05.070. [DOI] [PubMed] [Google Scholar]
- 84.Temporary anchorage devices: an insight. Aravindaksha R, Deepak C, Kritika A, Deenadayalan P. https://www.jrmds.in/articles/temporary-anchorage-devices-an-insight.pdf J Res Med Dent Sci. 2021;9:206–211. [Google Scholar]