Abstract
Background:
Prior studies have established the safety and efficacy of conduction system pacing (CSP) in improving echocardiographic parameters and clinical outcomes. This meta-analysis aimed to investigate whether CSP could reduce the occurrence of new-onset atrial fibrillation (AF) in comparison to traditional right ventricular pacing (RVP) therapy.
Methods:
A literature search was performed in PubMed, Embase, and the Cochrane Library to identify relevant clinical studies comparing CSP with RVP from January 2000 to June 2024. The study outcome was new-onset AF after pacemaker implantation. Estimated risk ratios (RR), odds ratio (OR) with 95% confidence intervals (CI) were evaluated.
Results:
Our analysis included 8 observational studies comprising a total of 2033 patients. The results indicated that 20% (406/2033) of study patients experienced new-onset AF, and CSP was associated with a significantly lower risk of new-onset AF when compared with RVP (RR: 0.44, 95% CI: 0.36–0.54, p < 0.00001, I2 = 11%; OR: 0.34, 95% CI: 0.27–0.44, p < 0.0001, I2 = 0). In the subgroup analysis, patients with atrioventricular block (AVB) tended to benefit more from CSP than those with sinus node dysfunction (SND) or AVB (p = 0.06 for RR; p = 0.12 for OR). Publication bias was observed and confirmed by the Egger's test (p = 0.0125 for RR and 0.0345 for OR). Trim and fill analysis was performed, and the overall summary effect size (RR: 0.51, 95% CI: 0.40–0.64; OR: 0.40, 95% CI: 0.31–0.52) remained significant after adjusting for publication bias.
Conclusion:
CSP could reduce the occurrence of new-onset AF compared with RVP, and this benefit appeared to be more pronounced in patients with AVB than those with SND or AVB. However, large scale randomized controlled trials are needed to validate our findings.
The PROSPERO Registration:
Registration number: CRD42024569052; registration date: July 25, 2024; https://www.crd.york.ac.uk/PROSPERO/view/CRD42024569052.
Keywords: atrial fibrillation, His bundle pacing, left bundle branch pacing, right ventricular pacing, meta-analysis
1. Introduction
Cardiac pacing is usually indicated in patients with symptomatic bradycardia including sinus node dysfunction (SND) and atrioventricular conduction disorders to improve quality of life and life expectancy [1]. However, chronic right ventricular (RV) pacing (RVP), whether from the RV apex or septum, is correlated to increased risk of new-onset atrial fibrillation (AF) and heart failure (HF) hospitalization, especially in patients with a high ventricular pacing (VP) burden [2, 3, 4]. Long-term RVP could induce electromechanical desynchrony, which in turn resulted in the enlargement and decreased function of the left atrium (LA) [5, 6]. This atrial remodeling might theoretically contribute to the occurrence of atrial arrhythmias. Thus, alternative pacing sites are being explored for a better clinical outcome.
Currently, conduction system pacing (CSP), which includes His bundle pacing (HBP) and left bundle branch pacing (LBBP), has been recognized as a potential alternative pacing strategy in clinical practice because it restores or preserves the ventricular activation by stimulating the His-Purkinje system directly. Massive studies have proven the safety and efficacy of CSP in a wide range of patients in improving echocardiographic parameters and clinical outcomes [7, 8]. In a retrospective single-center study that composed of 477 patients, Pastore et al. [3] found that HBP exhibited a lower incidence of persistent/permanent AF when compared with RVP. Subsequently, more studies focused on the risk of AF after CSP [9, 10, 11, 12], and one meta-analysis reported a reduced risk of new-onset AF in LBBP group compared with RVP group [13]. Considering the recently published studies comparing the risk of new-onset AF between CSP and RVP [14, 15], an updated meta-analysis was needed to combine previous and current evidence for comprehensively assessing the association between CSP and new-onset AF. Therefore, this study aimed to evaluate the impact of CSP on new-onset AF in comparison to conventional RVP in patients without AF history.
2. Methods
This meta-analysis was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement [16] and registered at the Prospective International Register of Systematic Reviews (PROSPERO, registration number CRD42024569052; registration date: July 25, 2024; https://www.crd.york.ac.uk/PROSPERO/view/CRD42024569052).
2.1 Search Strategy
A literature search utilizing PubMed, Embase, and the Cochrane library was conducted to retrieve all relevant studies from January 2000 to June 2024, because permanent HBP in human was first reported in 2000 by Deshmukh et al. [17]. The following search terms were used: “His bundle pacing, left bundle branch pacing, left bundle branch area pacing, right ventricular pacing, atrial fibrillation, atrial high rate episode”. Furthermore, the references of all included studies were also assessed to identify possibly relevant studies.
2.2 Study Selection
Two independent reviewers (TG and ZL) assessed the retrieved citations for inclusion and any controversies were resolved through discussion with a third investigator (XX). A study was enrolled in the analysis based on the following criteria: (1) randomized controlled trials (RCTs) and observational studies which directly compared the effects of CSP (HBP or LBBP) with RVP in bradyarrhythmia patients indicated for de novo pacemaker (PM) implantation, and (2) the study reported the occurrence of AF in each group, and (3) published in English, and (4) the minimum follow-up time 6 months, (5) conference abstracts and letters were also included if they met the four aforementioned criteria. We excluded: (1) editorials, reviews, case reports and meta-analyses, and (2) the study included patients with prior AF history but the new-onset AF incidence could not be distinguished in patients without AF history.
2.3 Study Outcomes
The primary outcome was the new-onset AF including clinical AF or sub-clinical AF (SCAF) defined as atrial high rate episodes (AHREs) detected by PM.
2.4 Data Collection and Quality Assessment
Two independent investigators (TG and ZL) extracted pertinent data employing a predefined data extraction form, which was subsequently verified by another two authors (WL and XW). Data regarding characteristics of the study, patients’ baseline characteristics, pacing model, ventricular pacing burden, the incidence of new-onset AF, and follow-up were extracted and collected. The quality of the observational studies was evaluated by two authors (XX and TG) utilizing the Newcastle-Ottawa Scale (NOS).
2.5 Statistical Analysis
Risk ratio (RR), odds ratio (OR) with 95% confidence interval (CI) were calculated as summary estimates. Heterogeneity was assessed using the Cochran’s Q test with a significance level at p 0.10. Also, the Higgins I-squared (I2) statistic was used to test heterogeneity, and I2 values 25%, 25%–49%, and 50% were considered low, moderate, and high degrees of heterogeneity, respectively. A fixed-effects model was utilized for meta-analysis if there was no significant heterogeneity among the studies. Otherwise, a random-effects model was utilized. The sensitivity analysis was conducted to identify the source of heterogeneity using the leave-one-out method. Publication bias was evaluated by funnel plot analysis and Egger’s test, and a ‘trim and fill’ approach was utilized to correct it if there was a publication bias [18]. Subgroup analyses were performed according to study design, pacing mode, pacing indication, follow-up and sample size. Revman 5.4 (the Cochrane Collaboration, Copenhagen, Denmark) and Stata Software (version 17, Statacorp, College Station, TX, USA) were used for all statistical analyses.
3. Results
3.1 Baseline Characteristics
As presented in Fig. 1, the initial search generated 1492 citations after deduplication, of which 38 were deemed to be potentially eligible for inclusion. Ultimately, 8 observational studies were enrolled in our analysis comprising a total of 2033 patients. The quality of all eligible studies was assessed with high NOS scores as shown in Table 1 (Ref. [3, 9, 10, 11, 12, 14, 15, 19]).
Fig. 1.
Flow diagram for study selection.
Table 1.
Quality assessment of the included studies by using the Newcastle-Ottawa Scale.
Criteria | Pastore G 2016 [3] | Ravi V 2020 [10] | Ravi V 2022 [11] | Zhu HJ 2023 [9] | Yang WY 2024 [14] | Zhang SG 2024 [15] | Takahashi M 2024 [12] | Ramos-Maqueda J 2024 [19] |
Representativeness of the exposed cohort | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Selection of the non-exposed cohort | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Ascertainment of exposure | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Outcome of interest was not present at the start | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Comparability | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1 |
Assessment of outcome | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Enough follow-up | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Adequacy of follow-up | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 |
Total | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 7 |
Quality | High | High | High | High | High | High | High | High |
Of these 8 studies, 3 compared HBP with RVP (203 vs 397 patients) [3, 10, 12] and 5 evaluated the occurrence rate of new-onset AF between LBBP and RVP (679 vs 754 patients) [9, 11, 14, 15, 19]. Three were prospectively designed and the remaining 5 were retrospective. There were 6 original articles, one letter [11], and one abstract [19]. The pacing indication included SND or atrioventricular block (AVB) in 3 studies [9, 10, 19] and exclusively AVB in 4 studies [3, 12, 14, 15]. Four studies [3, 12, 14, 15] with a pacing indication of AVB reported a significantly high VP percentage (VP%, 85%~100%). As for the definition of new-onset AF, the majority of the studies (at least 7 out of 8 studies) confirmed the diagnosis of AF based on PM-detected AHREs which usually were manually checked. Three studies [9, 10, 11] reported the occurrence rate of new-onset AF in different subgroups categorized by VP%, which suggested that patients with VP% 20% could benefit more from CSP therapy in terms of a lower occurrence of new-onset AF. The main baseline characteristics of enrolled studies and patients are presented in Table 2 (Ref. [3, 9, 10, 11, 12, 14, 15, 19]).
Table 2.
Baseline characteristics of included studies in this meta-analysis.
Study | Study design | Pacing mode | Sample size | Indication for pacing | Age (years) | LVEF (%) | LAD (mm) | VP burden (%) | FU (months) | Outcomes of atrial fibrillation |
Pastore G 2016 [3] | retrospective | HBP | 148 | AVB | 74.1 8.5 | 62 7 | 47.6 8.1 | 100% | 67.2 28.7 | (1) The first occurrence of persistent or permanent AF in patients without a prior AF history; (2) The first occurrence of progression to persistent or permanent AF in patients with previous AF event before PM implantation |
RVS or RVA | 140 | 76.9 7.0 | 60 8 | 46.5 7.8 | 53.2 23.7 | |||||
189 | 79.1 8.3 | 60 7 | 48.2 8.1 | 55.2 27.2 | ||||||
Ravi V 2020 [10] | retrospective | HBP | 105 | SND or AVB | 72.65 11.04 | 59.84 8.06 | NA | NA | 23.4 10.8 | (1) New onset AF among patients without a known history of AF; (2) Progression of AF defined as an absolute increase in average daily AF burden by 10% from the AF burden at initial device follow-up |
RVP | 120 | 76.54 9.87 | 61 7.19 | |||||||
Ravi V 2022 [11] | retrospective | LBBAP | 173 | NA | NA | NA | NA | NA | 20 9.3 | New-onset AF episodes 30 seconds or 6 minutes detected on scheduled device follow-up performed in-person and remotely |
RVP | 237 | |||||||||
Zhu HJ 2023 [9] | prospective | LBBAP | 257 | SND or AVB | 63.6 13.5 | 62.8 4.9 | 36.9 5.6 | NA | 11.1 7.5 | New-onset AF was defined as device-detected AF episodes lasting at least 30 s on intracardiac electrogram or surface 12-lead ECG. AHREs (atrial rate 190 bpm) detected by devices should be manually checked |
RVP | 270 | 66.9 11.5 | 63.1 5.4 | 37.5 5.9 | ||||||
Yang WY 2024 [14] | retrospective | LBBAP | 16 | AVB | 68.19 14.77 | 67.31 7.02 | 37.61 4.23 | 85 | 37.9 | AHREs were defined as events with an atrial frequency of 176 bpm lasting for 6 minutes recorded by PM during follow-up. AHREs should be manually checked |
RVS or RVA | 13 | 75.08 9.01 | 64.92 3.37 | 40.1 5.94 | 30 | |||||
11 | 67.64 15.49 | 62.39 8.89 | 39.76 6.59 | 28.6 | ||||||
Zhang SG 2024 [15] | prospective | LBBAP | 43 | AVB | 75.0 10.6 | 62.2 2.5 | 38.6 5.0 | 99.6 1.0 | 14.1 7.5 | AHREs were defined as events with an atrial frequency of 175 bpm and a duration of 5 min detected by a PM device. AHREs should be manually checked |
RVP | 43 | 72.4 10.0 | 63.3 5.2 | 38.1 4.5 | 88.1 20.9 | |||||
Takahashi M 2024 [12] | retrospective | HBP | 22 | AVB | 79 8 | 68.5 3.6 | 39.4 6.7 | 99 2 | 21.1 6 | New-onset AHREs was defined as AHREs which occurred more than 3 months after PM implantation and lasted for 6 minutes at an atrial heart rate 190 bpm |
RVP | 47 | 78 8 | 66.7 5.0 | 36.5 6.3 | 97 10 | 16.8 8 | ||||
Ramos-Maqueda J 2024 [19] | prospective | LBBAP | 198 | SND or AVB | 81.8 6.4 | 58.4 5.9 | NA | NA | 24 | New-onset AF was defined as device-detected AF at least 6 minutes on intracardiac electrocardiogram or surface ECG |
RVS | 193 | 82.3 7 | 59.4 6 |
Abbreviations: AF, atrial fibrillation; AHREs, atrial high rate episodes; AVB, atrioventricular block; ECG, electrogram; FU, follow-up; HBP, His bundle pacing; LAD, left atrium diameter; LBBAP, left bundle branch area pacing; LVEF, left ventricular ejection fraction; NA, not available; PM, pacemaker; RVA, right ventricular apex; RVP, right ventricular pacing; RVS, right ventricular septum; SND, sinus node dysfunction; VP, ventricular pacing.
3.2 Results from Meta-analysis
Pooled analysis indicated that new-onset AF developed in 20% (406/2033) of all patients, and a lower incidence of new-onset AF was observed in the CSP group when compared with the RVP group (12.2% vs 25.9%). CSP was correlated to a significantly reduced risk of new-onset AF when compared with RVP whether using fixed effects model (RR: 0.44, 95% CI: 0.36–0.54, p 0.00001; OR: 0.34, 95% CI: 0.27–0.44, p 0.0001) or random effects model (RR: 0.46, 95% CI: 0.37–0.57, p 0.0001; OR: 0.35, 95% CI: 0.27–0.46, p 0.0001), and no substantial heterogeneity was found (p = 0.34–0.62, I2 = 0–11%) (Fig. 2 and Supplementary Fig. 1). Whether using random-effects models or fixed effects model with conservative 95% CI adjustment, the omission of each trial at a time showed a consistent result favoring CSP in reducing the occurrence rate of new-onset AF compared with RVP (Fig. 3 and Supplementary Fig. 2).
Fig. 2.
Forest plot of pooled results for new-onset AF between CSP and RVP group. AF, atrial fibrillation; CSP, conduction system pacing; RVP, right ventricular pacing; RR, risk ratios; CI, confidence interval.
Fig. 3.
Sensitivity analysis. RR, risk ratio; CI, confidence interval.
Subgroup analysis based on study design, pacing mode, pacing indication, follow-up and sample size was performed. As illustrated in Table 3, no significant difference was observed between the CSP and RVP groups in all the subgroup analyses, but the performance of CSP appeared more pronounced than RVP in patients with a pacing indication of AVB with a tendency to reduce the occurrence of new-onset AF (p = 0.06 for RR; p = 0.12 for OR).
Table 3.
Subgroup analysis.
A | |||||||
Subgroup | Number of included studies | CSP | RVP | RR (95% CI) | p | Group difference | |
Study design | Prospective studies | 3 | 72/490 | 137/493 | 0.53 [0.41, 0.68] | 0.00001 | 0.10 |
Retrospective studies | 5 | 36/392 | 161/658 | 0.37 [0.27, 0.52] | 0.00001 | ||
Pacing mode | HBP | 3 | 25/203 | 106/397 | 0.40 [0.26, 0.60] | 0.0001 | 0.57 |
LBBP | 5 | 83/679 | 192/754 | 0.46 [0.36, 0.58] | 0.00001 | ||
Pacing indication | SND or AVB | 3 | 82/519 | 154/526 | 0.54 [0.43, 0.68] | 0.00001 | 0.06 |
AVB | 4 | 17/190 | 101/388 | 0.32 [0.20, 0.53] | 0.00001 | ||
Follow-up | 20 months | 3 | 26/322 | 81/360 | 0.38 [0.25, 0.57] | 0.00001 | 0.39 |
20 months | 5 | 82/560 | 217/791 | 0.46 [0.37, 0.59] | 0.00001 | ||
Sample size | 100 patients | 3 | 9/81 | 47/114 | 0.27 [0.14, 0.54] | 0.0002 | 0.14 |
100 patients | 5 | 99/801 | 251/1037 | 0.47 [0.38, 0.58] | 0.00001 | ||
B | |||||||
Subgroup | Number of included studies | CSP | RVP | OR (95% CI) | p | Group difference | |
Study design | Prospective studies | 3 | 72/490 | 137/493 | 0.41 [0.29, 0.57] | 0.00001 | 0.16 |
Retrospective studies | 5 | 36/392 | 161/658 | 0.28 [0.19, 0.42] | 0.00001 | ||
Pacing mode | HBP | 3 | 25/203 | 106/397 | 0.31 [0.19, 0.51] | 0.00001 | 0.60 |
LBBP | 5 | 83/679 | 192/754 | 0.36 [0.27, 0.48] | 0.00001 | ||
Pacing indication | SND or AVB | 3 | 82/519 | 154/526 | 0.42 [0.31, 0.57] | 0.00001 | 0.12 |
AVB | 4 | 17/190 | 101/388 | 0.25 [0.14, 0.44] | 0.00001 | ||
Follow-up | 20 months | 3 | 26/322 | 81/360 | 0.32 [0.20, 0.51] | 0.00001 | 0.70 |
20 months | 5 | 82/560 | 217/791 | 0.35 [0.26, 0.48] | 0.00001 | ||
Sample size | 100 patients | 3 | 9/81 | 47/114 | 0.18 [0.08, 0.41] | 0.00001 | 0.10 |
100 patients | 5 | 99/801 | 251/1037 | 0.37 [0.28, 0.49] | 0.00001 |
Abbreviations: AVB, atrioventricular block; CI, confidence interval; CSP, conduction system pacing; HBP, His bundle pacing; LBBP, left bundle branch pacing; OR, odds ratio; RVP, right ventricular pacing; RR, risk ratio; SND, sinus node dysfunction.
3.3 Publication Bias
The funnel plot for the new-onset AF was asymmetrical (dark blue circles in Fig. 4 and Supplementary Fig. 3) and the p-value from the Egger’s test was 0.0125 for RR and 0.0345 for OR, respectively, revealing a significant publication bias. Thus, the trim and fill procedure was executed and 4 missing studies (dark orange circles in Fig. 4 and Supplementary Fig. 3) were imputed. After adjustment with imputed studies, the adjusted overall summary effect size was marginally larger than the originally calculated summary effect size but remained significant (RR: 0.51, 95% CI: 0.40–0.64; OR: 0.40, 95% CI: 0.31–0.52, Random-effects model, DerSimonian–Laird method). No evidence of a small study effect was detected, though publication bias might have influenced the observed results.
Fig. 4.
Funnel plot of random-effects model with trim and fill analysis using RR as effect size, showing original studies (dark blue circles) and imputed studies (dark orange circles). RR, risk ratio; CI, confidence interval.
4. Discussion
This is, as far as we know, the most comprehensive meta-analysis to date comparing the risk of new-onset AF between CSP and RVP therapy. The results indicated a significantly reduced incidence of new-onset AF in CSP group, and CSP was correlated to a 49% relative risk reduction when compared with RVP. Furthermore, this advantage of CSP appeared to be particularly evident in patients with a pacing indication of AVB.
New-onset AF was common in patients with PM, and it has been established that a higher VP% is strongly correlated to an increased AF incidence. In a recent meta-analysis including 54 studies comprising a total of 72,784 patients, the overall prevalence of new-onset SCAF was 24.6% in patients without AF history, ranging from 10.1% to 55.7% [20]. In our study, 25.9% of patients in RVP group developed new-onset AF, which was consistent with prior studies. The pathogenesis of VP associated new-onset AF was multifactorial, but the LA remodeling induced by ventricular dyssynchrony during RVP is one of the most important reasons [21, 22]. The non-physiological electrical activation of left ventricle (LV) induced by RVP could impair both the systolic and diastolic function of LV, leading to deleterious hemodynamic changes, including elevated LV end-diastolic pressure and decreased LV systolic volume, which subsequently results in increased LA afterload and LA enlargement. Analogous to long-term RVP, structural and functional changes of LA occurred even after a short-term RVP therapy, which could facilitate the development and progression of AF [6, 23, 24]. Prior clinical investigations have suggested that a higher RVP% is related to adverse clinical outcomes including new-onset AF and pacing-induced cardiomyopathy [1, 9, 10], and each 1% increase in VP% could increase the risk of AF by ~0.7%–1% [9, 25]. Thus, current guidelines recommend minimization of unnecessary VP through programming (I, A) and cardiac physiological pacing in individuals who are anticipated to require a substantial VP% 20%~40% (2a or 2b) [1, 26].
As the most physiological pacing strategy in nature, HBP could produce rapid and synchronous ventricular activation through native His-Purkinje system. As a result, compared with RVP, HBP usually yields a narrower paced QRS duration with a superior hemodynamic outcome, and is associated with a reduction in HF hospitalization and new-onset AF [27, 28]. In 2016, Pastore et al. [3] observed a reduced non-paroxysmal AF occurrence in the HBP group compared with the RVP group in patients without AF history after an average follow-up of 58.5 months. In another study by Ravi et al. [10], HBP exhibited the superior effect in reducing occurrence of new-onset AF compared with traditional RVP, and the benefit of HBP was primarily driven by individuals with VP% 20%. These findings of HBP were confirmed by our study which revealed a 60% relative risk reduction (RR: 0.40, 95% CI, 0.26–0.60) for new-onset AF as compared to RVP.
LBBP is one novel physiological pacing modality to achieve the synchronous LV activation and contraction by direct capture of the left conduction system, which offers several advantages in terms of electrical parameters including better pacing threshold and sensed amplitude compared with HBP [29]. LBBP produces a shortened QRS duration and preserves LV electromechanical synchrony, resulting in decreased rates of HF hospitalization and all-cause mortality as compared to RVP [30, 31]. One recent single-center study [32] comprising 19 patients with cardiac resynchronization therapy (CRT) indication compared biventricular pacing-CRT (BiVP-CRT), LBBP-CRP and HBP-CRP by assessing ventricular electrical synchronization and acute hemodynamic response. Though a relatively longer total ventricular activation time due to RV activation delay, LBBP produced a similar left ventricular synchrony and comparable hemodynamic effect when compared with HBP. Existing clinical evidence supports the potential of LBBP as the first-line CSP modality in the future. Zhao et al. [5] compared the atrial outcomes between LBBP and RV outflow tract septal pacing in a prospective controlled study enrolling 72 pace-dependent patients, and found that LBBP could increase LA stress, reduce LA pressure and improve LA ejection. Zhang et al. [15] observed a small but significant decrease in left atrial diameter in the LBBP group as compared to the RVP group after 1-year follow-up. These beneficial effects of LBBP on atrial remodeling could translate into real clinical benefits in reducing the development and progression of AF, as demonstrated by several observative studies [9, 11, 14, 15, 19]. The subgroup analysis in our study also indicated that LBBP exhibited a comparable effect in reducing new-onset AF compared with HBP, which provided additional clinical evidence for LBBP as the preferred CSP modality in terms of atrial arrhythmia prevention.
Undoubtedly, RVP% is linearly correlated with the risk of AF development, and CSP could reduce the risk of new-onset AF in patients requiring a substantial VP%. In the subgroup analysis based on pacing indications, patients with AVB appeared to benefit more from CSP than those with SND or AVB, probably due to the impact of 33.8% (358/701) patients with SND, who might necessitate less ventricular pacing. One study by Pastore et al. [33] indicated that the HBP might be correlated with a reduced risk of persistent AF in SND patients with a long basal PR interval (180 ms). One retrospective cohort study with 224,814 PM patients evaluated the real-world performance of CSP compared with traditional RVP, and the results indicated that LBBP leads exhibited the comparably excellent pacing parameters [34], without significant difference in complications [30]. The role of CSP, especially LBBP in patients with normal atrioventricular conduction warrants further research considering the likelihood of AVB development in patients with SND during follow-up [35].
For patients with PM, the device could provide us with valuable information about the detection, diagnosis, and pattern of AF through continuous monitoring of intracardiac electrical signals. Patients with SCAF had a 3-fold higher risk of clinical AF development as compared to those without SCAF, and SCAF was also substantially correlated with increased risk of systemic thromboembolism and HF hospitalization [36, 37]. Thus, it is of great clinical relevance to consider new-onset SCAF/AF as an important study endpoint when designing prospective RCTs related to CSP in the future.
Limitations
This meta-analysis has several limitations. Firstly, all studies enrolled in this meta-analysis were non-randomized, and the majority of them had a limited sample size. Secondly, the definition of new-onset AF was inconsistent among the enrolled studies. Thirdly, there was significant variation in lengths of follow-up, which was of great importance for estimating the study outcome. Fourthly, the study population differed in terms of the pacing indication (SND or AVB) among the enrolled studies, this led to a different VP% among the studies which might influence the incidence of the endpoint event. Fifthly, the impact of different atrial pacing sites on the risk of AF was not examined due to insufficient relevant data. These all might bias the aggregated results of the meta-analysis.
5. Conclusion
CSP, including HBP and LBBP, could reduce the incidence of new-onset AF as compared to RVP, and patients with AVB appeared to benefit more from CSP than RVP therapy. Large-scale RCTs are warranted to further evaluate the clinical efficacy of CSP on reducing the occurrence of new-onset AF.
Availability of Data and Materials
All data generated or analyzed during this study are included in this article. Further inquiries can be directed to the corresponding author.
Acknowledgment
We acknowledge the patients, their referring clinicians, and the brave front-lines that continue to risk their lives to save others.
Supplementary Material
Supplementary material associated with this article can be found, in the online version, at https://doi.org/10.31083/RCM27921.
Funding Statement
This research received no external funding.
Footnotes
Publisher’s Note: IMR Press stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Author Contributions
Research idea and study design: TG, and XX. Data acquisition: ZL, TG, WL, and XW. Statistical analysis: TG and XX. Data analysis and interpretation: TG, and XX. Results discussion: TG, ZL, WL, XW, and XX. Manuscript drafting: TG and XX. Manuscript review and supervision: XX. All authors contributed to editorial changes in the manuscript. All authors read and approved the final manuscript. All authors have participated sufficiently in the work and agreed to be accountable for all aspects of the work.
Ethics Approval and Consent to Participate
Not applicable.
Funding
This research received no external funding.
Conflict of Interest
The authors declare no conflict of interest.
References
- [1].Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. European Heart Journal . 2021;42:3427–3520. doi: 10.1093/eurheartj/ehab364. [DOI] [PubMed] [Google Scholar]
- [2].Hayashi K, Kohno R, Fujino Y, Takahashi M, Oginosawa Y, Ohe H, et al. Pacing From the Right Ventricular Septum and Development of New Atrial Fibrillation in Paced Patients With Atrioventricular Block and Preserved Left Ventricular Function. Circulation Journal: Official Journal of the Japanese Circulation Society . 2016;80:2302–2309. doi: 10.1253/circj.CJ-16-0640. [DOI] [PubMed] [Google Scholar]
- [3].Pastore G, Zanon F, Baracca E, Aggio S, Corbucci G, Boaretto G, et al. The risk of atrial fibrillation during right ventricular pacing. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology . 2016;18:353–358. doi: 10.1093/europace/euv268. [DOI] [PubMed] [Google Scholar]
- [4].Ng ACT, Allman C, Vidaic J, Tie H, Hopkins AP, Leung DY. Long-term impact of right ventricular septal versus apical pacing on left ventricular synchrony and function in patients with second- or third-degree heart block. The American Journal of Cardiology . 2009;103:1096–1101. doi: 10.1016/j.amjcard.2008.12.029. [DOI] [PubMed] [Google Scholar]
- [5].Zhao Y, Liu Q, Wu J, Zhang Y, You L, Xie R. Left bundle branch area pacing improving the left atrial outcomes in pace-dependent patients compared with right ventricular outflow tract septal pacing. Clinical Cardiology . 2024;47:e24185. doi: 10.1002/clc.24185. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [6].Lee WC, Chang WT, Fang HY, Chen HC, Chen MC, Liu PY. Incidence, Risk Factors, and Outcomes of Left Atrial Enlargement in Patients Requiring Right Ventricular Pacing: A Retrospective Study of 461 Cases from 2012 to 2020. Medical Science Monitor: International Medical Journal of Experimental and Clinical Research . 2024;30:e944114. doi: 10.12659/MSM.944114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [7].Infeld M, Cyr JA, Sánchez-Quintana D, Madias C, Udelson JE, Lustgarten DL, et al. Physiological Pacing for the Prevention and Treatment of Heart Failure: a State-of-the-Art Review. Journal of Cardiac Failure . 2024;30:1614–1628. doi: 10.1016/j.cardfail.2024.08.063. [DOI] [PubMed] [Google Scholar]
- [8].Beer D, Vijayaraman P. Current Role of Conduction System Pacing in Patients Requiring Permanent Pacing. Korean Circulation Journal . 2024;54:427–453. doi: 10.4070/kcj.2024.0113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [9].Zhu H, Li X, Wang Z, Liu Q, Chu B, Yao Y, et al. New-onset atrial fibrillation following left bundle branch area pacing vs. right ventricular pacing: a two-centre prospective cohort study. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology . 2023;25:121–129. doi: 10.1093/europace/euac132. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [10].Ravi V, Beer D, Pietrasik GM, Hanifin JL, Ooms S, Ayub MT, et al. Development of New-Onset or Progressive Atrial Fibrillation in Patients With Permanent HIS Bundle Pacing Versus Right Ventricular Pacing: Results From the RUSH HBP Registry. Journal of the American Heart Association . 2020;9:e018478. doi: 10.1161/JAHA.120.018478. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [11].Ravi V, Sharma PS, Patel NR, Dommaraju S, Zalavadia DV, Garg V, et al. New-Onset Atrial Fibrillation in Left Bundle Branch Area Pacing Compared With Right Ventricular Pacing. Circulation. Arrhythmia and Electrophysiology . 2022;15:e010710. doi: 10.1161/CIRCEP.121.010710. [DOI] [PubMed] [Google Scholar]
- [12].Takahashi M, Kujiraoka H, Arai T, Kimura T, Hojo R, Fukamizu S. New-onset atrial high-rate episodes between his bundle pacing and conventional right ventricular septum pacing in patients with atrioventricular conduction disturbance. Journal of Interventional Cardiac Electrophysiology: an International Journal of Arrhythmias and Pacing . 2024;67:471–477. doi: 10.1007/s10840-023-01605-w. [DOI] [PubMed] [Google Scholar]
- [13].Liu B, Dai W, Lou Y, Li Y, Wu Y, Du J. Risk of Atrial Fibrillation Following Left Bundle Branch Area Pacing versus Right Ventricular Pacing and Biventricular Pacing: A Systematic Review and Meta-Analysis. Reviews in Cardiovascular Medicine . 2023;24:220. doi: 10.31083/j.rcm2408220. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [14].Yang WY, Di BB, Peng H, Sun ZJ. Comparison between left bundle branch area pacing and right ventricular pacing: ventricular electromechanical synchrony and risk of atrial high-rate episodes. Frontiers in Cardiovascular Medicine . 2024;11:1267076. doi: 10.3389/fcvm.2024.1267076. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [15].Zhang S, Yang W, Wang S, Cheng Y, Jiang Z, Zhou X, et al. New-onset atrial high-rate episodes in left bundle branch area pacing versus right ventricular pacing for patients with atrioventricular block. Kardiologia Polska . 2024;82:632–639. doi: 10.33963/v.phj.100403. [DOI] [PubMed] [Google Scholar]
- [16].Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Medicine . 2009;6:e1000097. doi: 10.1371/journal.pmed.1000097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [17].Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation . 2000;101:869–877. doi: 10.1161/01.cir.101.8.869. [DOI] [PubMed] [Google Scholar]
- [18].Borge TC, Aase H, Brantsæter AL, Biele G. The importance of maternal diet quality during pregnancy on cognitive and behavioural outcomes in children: a systematic review and meta-analysis. BMJ Open . 2017;7:e016777. doi: 10.1136/bmjopen-2017-016777. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [19].Ramos-Maqueda J, Arriaga-Jiménez AE, Melero-Polo J, Cabrera-Ramos M, Molina-Lerma M. New-onset atrial fibrillation in left bundle branch area pacing vs right ventricular septal pacing in high-risk patients for atrial fibrillation. Heart Rhythm . 2024;21:S379. [Google Scholar]
- [20].Proietti M, Romiti GF, Vitolo M, Borgi M, Rocco AD, Farcomeni A, et al. Epidemiology of subclinical atrial fibrillation in patients with cardiac implantable electronic devices: A systematic review and meta-regression. European Journal of Internal Medicine . 2022;103:84–94. doi: 10.1016/j.ejim.2022.06.023. [DOI] [PubMed] [Google Scholar]
- [21].Kreimer F, Gotzmann M. Pacemaker-induced atrial fibrillation reconsidered-associations with different pacing sites and prevention approaches. Frontiers in Cardiovascular Medicine . 2024;11:1412283. doi: 10.3389/fcvm.2024.1412283. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [22].Wu Y, Xu H, Tu X, Gao Z. Review of the epidemiology, pathogenesis and prevention of atrial fibrillation after pacemaker implantation. Advances in Clinical and Experimental Medicine: Official Organ Wroclaw Medical University . 2023;32:707–718. doi: 10.17219/acem/157239. [DOI] [PubMed] [Google Scholar]
- [23].Xie JM, Fang F, Zhang Q, Sanderson JE, Chan JYS, Lam YY, et al. Acute effects of right ventricular apical pacing on left atrial remodeling and function. Pacing and Clinical Electrophysiology: PACE . 2012;35:856–862. doi: 10.1111/j.1540-8159.2012.03403.x. [DOI] [PubMed] [Google Scholar]
- [24].Xie JM, Fang F, Zhang Q, Chan JYS, Yip GWK, Sanderson JE, et al. Left atrial remodeling and reduced atrial pump function after chronic right ventricular apical pacing in patients with preserved ejection fraction. International Journal of Cardiology . 2012;157:364–369. doi: 10.1016/j.ijcard.2010.12.075. [DOI] [PubMed] [Google Scholar]
- [25].Sweeney MO, Hellkamp AS, Ellenbogen KA, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation . 2003;107:2932–2937. doi: 10.1161/01.CIR.0000072769.17295.B1. [DOI] [PubMed] [Google Scholar]
- [26].Chung MK, Patton KK, Lau CP, Dal Forno ARJ, Al-Khatib SM, Arora V, et al. 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm . 2023;20:e17–e91. doi: 10.1016/j.hrthm.2023.03.1538. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [27].Abdin A, Aktaa S, Vukadinović D, Arbelo E, Burri H, Glikson M, et al. Outcomes of conduction system pacing compared to right ventricular pacing as a primary strategy for treating bradyarrhythmia: systematic review and meta-analysis. Clinical Research in Cardiology: Official Journal of the German Cardiac Society . 2022;111:1198–1209. doi: 10.1007/s00392-021-01927-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [28].Hoyt RH, Kelley BP, Harry MJ, Marcus RH. Hemodynamic Doppler echocardiographic evaluation of permanent His bundle and biventricular pacing after AV nodal ablation. International Journal of Cardiology. Heart & Vasculature . 2022;42:101102. doi: 10.1016/j.ijcha.2022.101102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [29].Hua W, Fan X, Li X, Niu H, Gu M, Ning X, et al. Comparison of Left Bundle Branch and His Bundle Pacing in Bradycardia Patients. JACC. Clinical Electrophysiology . 2020;6:1291–1299. doi: 10.1016/j.jacep.2020.05.008. [DOI] [PubMed] [Google Scholar]
- [30].Leventopoulos G, Travlos CK, Aronis KN, Anagnostopoulou V, Patrinos P, Papageorgiou A, et al. Safety and efficacy of left bundle branch area pacing compared with right ventricular pacing in patients with bradyarrhythmia and conduction system disorders: Systematic review and meta-analysis. International Journal of Cardiology . 2023;390:131230. doi: 10.1016/j.ijcard.2023.131230. [DOI] [PubMed] [Google Scholar]
- [31].Tan ESJ, Soh R, Boey E, Lee JY, de Leon J, Chan SP, et al. Comparison of Pacing Performance and Clinical Outcomes Between Left Bundle Branch and His Bundle Pacing. JACC. Clinical Electrophysiology . 2023;9:1393–1403. doi: 10.1016/j.jacep.2022.12.022. [DOI] [PubMed] [Google Scholar]
- [32].Ali N, Arnold AD, Miyazawa AA, Keene D, Chow JJ, Little I, et al. Comparison of methods for delivering cardiac resynchronization therapy: an acute electrical and haemodynamic within-patient comparison of left bundle branch area, His bundle, and biventricular pacing. Europace: European Pacing, Arrhythmias, and Cardiac Electrophysiology: Journal of the Working Groups on Cardiac Pacing, Arrhythmias, and Cardiac Cellular Electrophysiology of the European Society of Cardiology . 2023;25:1060–1067. doi: 10.1093/europace/euac245. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [33].Pastore G, Marcantoni L, Lanza D, Maines M, Noventa F, Corbucci G, et al. Occurrence of persistent atrial fibrillation during pacing for sinus node disease: The influence of His bundle pacing versus managed ventricular pacing. Journal of Cardiovascular Electrophysiology . 2021;32:110–116. doi: 10.1111/jce.14810. [DOI] [PubMed] [Google Scholar]
- [34].Kron J, Bernabei M, Kaiser D, Nanda S, Subzposh FA, Zimmerman P, et al. Real-World Performance of Conduction System Pacing Compared With Traditional Pacing. Circulation. Arrhythmia and Electrophysiology . 2023;16:411–412. doi: 10.1161/CIRCEP.123.012014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [35].Edwards SJ, Karner C, Trevor N, Wakefield V, Salih F. Dual-chamber pacemakers for treating symptomatic bradycardia due to sick sinus syndrome without atrioventricular block: a systematic review and economic evaluation. Health Technology Assessment (Winchester, England) . 2015;19:1–210. doi: 10.3310/hta19650. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [36].Wong JA, Conen D, Van Gelder IC, McIntyre WF, Crijns HJ, Wang J, et al. Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure. Journal of the American College of Cardiology . 2018;71:2603–2611. doi: 10.1016/j.jacc.2018.03.519. [DOI] [PubMed] [Google Scholar]
- [37].Vitolo M, Imberti JF, Maisano A, Albini A, Bonini N, Valenti AC, et al. Device-detected atrial high rate episodes and the risk of stroke/thrombo-embolism and atrial fibrillation incidence: a systematic review and meta-analysis. European Journal of Internal Medicine . 2021;92:100–106. doi: 10.1016/j.ejim.2021.05.038. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data generated or analyzed during this study are included in this article. Further inquiries can be directed to the corresponding author.