Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aschenberg W., Schlüter M., Kremer P., Schröder E., Siglow V., Bleifeld W. Transesophageal two-dimensional echocardiography for the detection of left atrial appendage thrombus. J Am Coll Cardiol. 1986 Jan;7(1):163–166. doi: 10.1016/s0735-1097(86)80275-3. [DOI] [PubMed] [Google Scholar]
- Beaupre P. N., Kremer P. F., Cahalan M. K., Lurz F. W., Schiller N. B., Hamilton W. K. Intraoperative detection of changes in left ventricular segmental wall motion by transesophageal two-dimensional echocardiography. Am Heart J. 1984 May;107(5 Pt 1):1021–1023. doi: 10.1016/0002-8703(84)90844-5. [DOI] [PubMed] [Google Scholar]
- Clements F. M., de Bruijn N. P. Perioperative evaluation of regional wall motion by transesophageal two-dimensional echocardiography. Anesth Analg. 1987 Mar;66(3):249–261. [PubMed] [Google Scholar]
- Cucchiara R. F., Nugent M., Seward J. B., Messick J. M. Air embolism in upright neurosurgical patients: detection and localization by two-dimensional transesophageal echocardiography. Anesthesiology. 1984 Apr;60(4):353–355. doi: 10.1097/00000542-198404000-00013. [DOI] [PubMed] [Google Scholar]
- Ezekowitz M. D., Smith E. O., Rankin R., Harrison L. H., Jr, Krous H. F. Left atrial mass: diagnostic value of transesophageal 2-dimensional echocardiography and indium-111 platelet scintigraphy. Am J Cardiol. 1983 May 15;51(9):1563–1564. doi: 10.1016/0002-9149(83)90681-1. [DOI] [PubMed] [Google Scholar]
- Furuya H., Okumura F. Detection of paradoxical air embolism by transesophageal echocardiography. Anesthesiology. 1984 Apr;60(4):374–377. doi: 10.1097/00000542-198404000-00020. [DOI] [PubMed] [Google Scholar]
- Gussenhoven E. J., Taams M. A., Roelandt J. R., Ligtvoet K. M., McGhie J., van Herwerden L. A., Cahalan M. K. Transesophageal two-dimensional echocardiography: its role in solving clinical problems. J Am Coll Cardiol. 1986 Oct;8(4):975–979. doi: 10.1016/s0735-1097(86)80444-2. [DOI] [PubMed] [Google Scholar]
- Hanrath P., Schlüter M., Langenstein B. A., Polster J., Engel S., Kremer P., Krebber H. J. Detection of ostium secundum atrial septal defects by transoesophageal cross-sectional echocardiography. Br Heart J. 1983 Apr;49(4):350–358. doi: 10.1136/hrt.49.4.350. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Koolen J. J., Visser C. A., Wever E., van Wezel H., Meyne N. G., Dunning A. J. Transesophageal two-dimensional echocardiographic evaluation of biventricular dimension and function during positive end-expiratory pressure ventilation after coronary artery bypass grafting. Am J Cardiol. 1987 May 1;59(12):1047–1051. doi: 10.1016/0002-9149(87)90846-0. [DOI] [PubMed] [Google Scholar]
- Matsumoto M., Oka Y., Strom J., Frishman W., Kadish A., Becker R. M., Frater R. W., Sonnenblick E. H. Application of transesophageal echocardiography to continuous intraoperative monitoring of left ventricular performance. Am J Cardiol. 1980 Jul;46(1):95–105. doi: 10.1016/0002-9149(80)90611-6. [DOI] [PubMed] [Google Scholar]
- Reichek N., Priest C., Zimrin D., Chandler T., Sutton M. S. Antianginal effects of nitroglycerin patches. Am J Cardiol. 1984 Jul 1;54(1):1–7. doi: 10.1016/0002-9149(84)90295-9. [DOI] [PubMed] [Google Scholar]
- Rodigas P. C., Meyer F. J., Haasler G. B., Dubroff J. M., Spotnitz H. M. Intraoperative 2-dimensional echocardiography: ejection of microbubbles from the left ventricle after cardiac surgery. Am J Cardiol. 1982 Nov;50(5):1130–1132. doi: 10.1016/0002-9149(82)90431-3. [DOI] [PubMed] [Google Scholar]
- Roizen M. F., Beaupre P. N., Alpert R. A., Kremer P., Cahalan M. K., Shiller N., Sohn Y. J., Cronnelly R., Lurz F. W., Ehrenfeld W. K. Monitoring with two-dimensional transesophageal echocardiography. Comparison of myocardial function in patients undergoing supraceliac, suprarenal-infraceliac, or infrarenal aortic occlusion. J Vasc Surg. 1984 Mar;1(2):300–305. [PubMed] [Google Scholar]
- Schlüter M., Kremer P., Hanrath P. Transesophageal 2-D echocardiographic feature of flail mitral leaflet due to ruptured chordae tendineae. Am Heart J. 1984 Sep;108(3 Pt 1):609–610. doi: 10.1016/0002-8703(84)90434-4. [DOI] [PubMed] [Google Scholar]
- Schlüter M., Langenstein B. A., Polster J., Kremer P., Souquet J., Engel S., Hanrath P. Transoesophageal cross-sectional echocardiography with a phased array transducer system. Technique and initial clinical results. Br Heart J. 1982 Jul;48(1):67–72. doi: 10.1136/hrt.48.1.67. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Smith J. S., Cahalan M. K., Benefiel D. J., Byrd B. F., Lurz F. W., Shapiro W. A., Roizen M. F., Bouchard A., Schiller N. B. Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography. Circulation. 1985 Nov;72(5):1015–1021. doi: 10.1161/01.cir.72.5.1015. [DOI] [PubMed] [Google Scholar]
- Sprecher D. L., Adamick R., Adams D., Kisslo J. In vitro color flow, pulsed and continuous wave Doppler ultrasound masking of flow by prosthetic valves. J Am Coll Cardiol. 1987 Jun;9(6):1306–1310. doi: 10.1016/s0735-1097(87)80470-9. [DOI] [PubMed] [Google Scholar]
- Takamoto S., Omoto R. Visualization of thoracic dissecting aortic aneurysm by transesophageal Doppler color flow mapping. Herz. 1987 Jun;12(3):187–193. [PubMed] [Google Scholar]
- Thier W., Schlüter M., Krebber H. J., Polonius M. J., Klöppel G., Becker K., Hanrath P. Cysts in left atrial myxomas identified by transesophageal cross-sectional echocardiography. Am J Cardiol. 1983 Jun;51(10):1793–1795. doi: 10.1016/0002-9149(83)90233-3. [DOI] [PubMed] [Google Scholar]
- Topol E. J., Humphrey L. S., Borkon A. M., Baumgartner W. A., Dorsey D. L., Reitz B. A., Weiss J. L. Value of intraoperative left ventricular microbubbles detected by transesophageal two-dimensional echocardiography in predicting neurologic outcome after cardiac operations. Am J Cardiol. 1985 Nov 1;56(12):773–775. doi: 10.1016/0002-9149(85)91134-8. [DOI] [PubMed] [Google Scholar]
- Topol E. J., Weiss J. L., Guzman P. A., Dorsey-Lima S., Blanck T. J., Humphrey L. S., Baumgartner W. A., Flaherty J. T., Reitz B. A. Immediate improvement of dysfunctional myocardial segments after coronary revascularization: detection by intraoperative transesophageal echocardiography. J Am Coll Cardiol. 1984 Dec;4(6):1123–1134. doi: 10.1016/s0735-1097(84)80131-x. [DOI] [PubMed] [Google Scholar]
- de Bruijn N. P., Clements F. M., Kisslo J. A. Intraoperative transesophageal color flow mapping: initial experience. Anesth Analg. 1987 May;66(5):386–390. doi: 10.1213/00000539-198705000-00002. [DOI] [PubMed] [Google Scholar]