Abstract
Instantaneous cross sectional flow velocity profiles from early mitral flow in 10 healthy men were constructed by time interpolation of the velocity data from each point in sequentially delayed two dimensional digital Doppler ultrasound maps. This interpolation allows correction of the artificially produced skewness of velocities across the flow sector caused by the time taken to scan the flow sector for velocity recording of pulsatile blood flow. These results suggested that early mitral flow studied in an apical four chamber view is variably skewed both at the leaflet tips and at the annulus. The maximum flow velocity overestimated the cross sectional mean velocity at the same time by a factor of 1.2-2.2. Also the maximum time velocity integral overestimated the cross sectional mean time velocity integral to the same extent. This cross sectional skew must be taken into account when calculation of blood flow is based on recordings with pulsed wave Doppler ultrasound from a single sample volume.
Full text
PDF







Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Appleton C. P., Hatle L. K., Popp R. L. Relation of transmitral flow velocity patterns to left ventricular diastolic function: new insights from a combined hemodynamic and Doppler echocardiographic study. J Am Coll Cardiol. 1988 Aug;12(2):426–440. doi: 10.1016/0735-1097(88)90416-0. [DOI] [PubMed] [Google Scholar]
- Dittmann H., Voelker W., Karsch K. R., Seipel L. Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography. J Am Coll Cardiol. 1987 Oct;10(4):818–823. doi: 10.1016/s0735-1097(87)80275-9. [DOI] [PubMed] [Google Scholar]
- Jenni R., Ruffmann K., Vieli A., Anliker M., Krayenbuehl H. P. Dynamics of aortic flow in hypertrophic cardiomyopathy. Eur Heart J. 1985 May;6(5):391–398. doi: 10.1093/oxfordjournals.eurheartj.a061877. [DOI] [PubMed] [Google Scholar]
- Jenni R., Vieli A., Ruffmann K., Krayenbuehl H. P., Anliker M. A comparison between single gate and multigate ultrasonic Doppler measurements for the assessment of the velocity pattern in the human ascending aorta. Eur Heart J. 1984 Nov;5(11):948–953. doi: 10.1093/oxfordjournals.eurheartj.a061596. [DOI] [PubMed] [Google Scholar]
- Kitabatake A., Inoue M., Asao M., Tanouchi J., Masuyama T., Abe H., Morita H., Senda S., Matsuo H. Transmitral blood flow reflecting diastolic behavior of the left ventricle in health and disease--a study by pulsed Doppler technique. Jpn Circ J. 1982 Jan;46(1):92–102. doi: 10.1253/jcj.46.92. [DOI] [PubMed] [Google Scholar]
- Klipstein R. H., Firmin D. N., Underwood S. R., Rees R. S., Longmore D. B. Blood flow patterns in the human aorta studied by magnetic resonance. Br Heart J. 1987 Oct;58(4):316–323. doi: 10.1136/hrt.58.4.316. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Matsuo H., Kitabatake A., Hayashi T., Asao M., Terao Y. Intracardiac flow dynamics with bi-directional ultrasonic pulsed Doppler technique. Jpn Circ J. 1977 May;41(5):515–528. doi: 10.1253/jcj.41.515. [DOI] [PubMed] [Google Scholar]
- Miyatake K., Izumi S., Shimizu A., Kinoshita N., Okamoto M., Sakakibara H., Nimura Y. Right atrial flow topography in healthy subjects studied with real-time two-dimensional Doppler flow imaging technique. J Am Coll Cardiol. 1986 Feb;7(2):425–431. doi: 10.1016/s0735-1097(86)80516-2. [DOI] [PubMed] [Google Scholar]
- Nayler G. L., Firmin D. N., Longmore D. B. Blood flow imaging by cine magnetic resonance. J Comput Assist Tomogr. 1986 Sep-Oct;10(5):715–722. doi: 10.1097/00004728-198609000-00001. [DOI] [PubMed] [Google Scholar]
- Nicolosi G. L., Pungercic E., Cervesato E., Pavan D., Modena L., Moro E., Dall'Aglio V., Zanuttini D. Feasibility and variability of six methods for the echocardiographic and Doppler determination of cardiac output. Br Heart J. 1988 Mar;59(3):299–303. doi: 10.1136/hrt.59.3.299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Paulsen P. K., Hasenkam J. M. Three-dimensional visualization of velocity profiles in the ascending aorta in dogs, measured with a hot-film anemometer. J Biomech. 1983;16(3):201–210. doi: 10.1016/0021-9290(83)90127-6. [DOI] [PubMed] [Google Scholar]
- Robson S. C., Boys R. J., Hunter S. Doppler echocardiographic estimation of cardiac output: analysis of temporal variability. Eur Heart J. 1988 Mar;9(3):313–318. doi: 10.1093/oxfordjournals.eurheartj.a062502. [DOI] [PubMed] [Google Scholar]
- Seed W. A., Wood N. B. Velocity patterns in the aorta. Cardiovasc Res. 1971 Jul;5(3):319–330. doi: 10.1093/cvr/5.3.319. [DOI] [PubMed] [Google Scholar]
- Segadal L., Matre K. Blood velocity distribution in the human ascending aorta. Circulation. 1987 Jul;76(1):90–100. doi: 10.1161/01.cir.76.1.90. [DOI] [PubMed] [Google Scholar]
- Smith M. D., Grayburn P. A., Spain M. G., DeMaria A. N. Observer variability in the quantitation of Doppler color flow jet areas for mitral and aortic regurgitation. J Am Coll Cardiol. 1988 Mar;11(3):579–584. doi: 10.1016/0735-1097(88)91534-3. [DOI] [PubMed] [Google Scholar]
- Stewart W. J., Jiang L., Mich R., Pandian N., Guerrero J. L., Weyman A. E. Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations. J Am Coll Cardiol. 1985 Sep;6(3):653–662. doi: 10.1016/s0735-1097(85)80127-3. [DOI] [PubMed] [Google Scholar]
- Zhang Y., Nitter-Hauge S., Ihlen H., Myhre E. Doppler echocardiographic measurement of cardiac output using the mitral orifice method. Br Heart J. 1985 Feb;53(2):130–136. doi: 10.1136/hrt.53.2.130. [DOI] [PMC free article] [PubMed] [Google Scholar]
- de Zuttere D., Touche T., Saumon G., Nitenberg A., Prasquier R. Doppler echocardiographic measurement of mitral flow volume: validation of a new method in adult patients. J Am Coll Cardiol. 1988 Feb;11(2):343–350. doi: 10.1016/0735-1097(88)90100-3. [DOI] [PubMed] [Google Scholar]