Abstract
The blood-brain barrier (BBB) renders the delivery of nanomedicine in the brain ineffective and the detection of circulating disease-related DNA from the brain unreliable. Here, we show that the acoustic emission content of focused ultrasound-controlled microbubble dynamics (MB-FUS) incorporates precursor signals that allow large-data models to predict sonication regimens for safe and effective BBB opening. Crucially, closed-loop MB-FUS controller augmented by machine learning (ML-CL) expands the treatment window (4-fold), as compared to conventional controllers, by persistently and proactively maximizing the BBB permeability while preventing tissue damage. By successfully scaling up from mice to rats and from healthy to diseased brains (glioma), ML-CL rendered the BBB permeable to large nanoparticles and markedly improved the release and detection of tumor DNA in plasma. Together, our findings reveal the potential of data-driven feedback to support the development of next-generation AI-powered ultrasound systems for safe, robust, and efficient nanotheranostic targeting of brain diseases.
Introduction
The blood-brain barrier (BBB) constitutes a highly selective semi-permeable layer between the vascular lumen of capillaries and the brain parenchyma that tightly regulates the transport of macromolecules to support the metabolic demands of the brain and the clearance of soluble waste products1–4. Due to its properties, the BBB hinders the effective delivery of a wide range of therapeutic agents (larger than 400 Da5,6) into the brain, including highly potent nanotherapeutics6–9. It also limits the reliable release of soluble biomolecules into circulation – molecules that are associated with disease formation and progression – and are therefore essential for minimally invasive diagnosis and longitudinal monitoring of brain diseases through liquid biopsy techniques10,11. Hence, strategies to safely and effectively overcome the BBB – including its partially compromised, yet highly heterogenous permeability during disease progression6,12 – are critical for the diagnosis, treatment, and monitoring of central nervous system (CNS) diseases.
Circulating microbubbles (MB) upon focused ultrasound (FUS) exposure (sonication) can transiently increase the BBB permeability in a disease-agnostic way13–15 and facilitate mass transport across this biological interface in an exposure-dependent manner16,17. Notably, MB-FUS has been shown to increase the effective delivery of various therapeutic agents – including a broad spectrum of nano-formulations16 – across a wide range of brain diseases16,18,19. Despite promising preclinical findings, the quest to deliver an increasing fraction of intravenously administered nano-carriers into the brain20 combined with the need to incorporate larger and more potent cargos (e.g., gene editing nano-systems) that inevitably require larger constructs (≥60 nm)21, is probing scientists and clinicians to employ FUS exposures close to safety limits in order to maximize their penetration across the BBB22–27. Similar advancements and challenges have also been observed in the use of MB-FUS to promote the release of disease-associated soluble molecules from the brain into circulation. The integration of MB-FUS with liquid biopsy techniques – whereby biomarkers from sonicated tissues are transiently enriched in the circulation – enables the development of novel assays for diagnosing and characterizing brain diseases28–35. This includes the release of larger and scarcer molecules – such as circulating-tumor DNA (ctDNA, fragments ≥ 60 kDa) – which are critical for improving the sensitivity, specificity, and ultimately the diagnostic utility of these assays. However, such sono-interrogation approaches must carefully balance the need for aggressive sonication to improve biomarker release against the risk of inducing brain injury29–32,35.
Balancing BBB opening efficacy with safety requires effective and real-time control of the cerebrovascular MB dynamics16 – a highly nonlinear phenomenon that is prone to instabilities, such as MB collapse (i.e., inertial cavitation) that has long been linked to tissue damage36. Recent investigations have shown that recording and analyzing the acoustic emissions (AE) generated by MBs’ nanoscale oscillations – which incorporate strong nonlinear acoustic components – provides a robust way to adjust the sonication settings16. The sonication amplitude can be modified in real-time to attain prescribed strength of nonlinear acoustic components (i.e., Harmonics and/or Ultra-Harmonics) that are good proxies to stable oscillations and positively correlate with safe BBB opening. While this principle has formed the basis for developing real-time closed loop methods to maximize BBB opening17,37–46, safety remains a concern as all current control methods are reactive to the onset of broadband emission: a warning sign associated with MB collapse. That is, they rely on the detection of broadband emission events before triggering a “safety response” (i.e., rapid pressure drop). As a result, small damage from repeated treatment sessions targeting neurologically functional brain regions (e.g., tumor invading healthy brain or neurological diseases like Alzheimer’s) can be compounded47–50. Consequently, the “first do no harm” principle that dictates how new technologies and treatments are evaluated in the clinical space requires the adoption of conservative exposure settings during MB-FUS that inevitably leads to a very narrow acoustic treatment window (~ 50 kPa)16,36. The latter not only complicates the effective clinical translation and broad dissemination (i.e., similar to US imaging) of this technology, but also challenges its ability to consistently attain clinically meaningful endpoints related to the diagnosis, treatment, and treatment monitoring of CNS diseases.
Here, we employ data-driven models to extract precursor signals (i.e., patterns)51,52 that are within the MB AE to study and analyze the transition from stable to inertial MB oscillation. Through comprehensive analysis and training of the models, using more than 54,000 AE datasets collected in MB-FUS experiments in mice, we discover multi-dimensional relationships in features derived from nonlinear MB AE that can predict the onset of broadband emissions with high sensitivity. By integrating the trained model into a real-time closed-loop MB AE feedback controller we show that it can augment the MB-FUS acoustic treatment window by persistently and proactively maximizing the BBB permeability while preventing tissue damage. We show that this data-driven feedback overcomes barriers to the delivery of nanoparticles and markedly improves the release of soluble biomarkers (protein and ctDNA) in orthotopic glioma tumor model in rats. Collectively, our findings demonstrate that, by expanding the treatment window, data-driven feedback can augment ultrasound nanotheranostic targeting of brain tumors and support the development of next generation AI-powered ultrasound systems for improved diagnosis, treatment, and monitoring of brain diseases.
Results
Multilayer perceptron (MLP) achieves high sensitivity in predicting broadband emissions
In this proof-of-concept investigation, we applied a supervised classification machine learning (ML) model trained on 54,040 acoustic emission (AE) datasets from BBB opening experiments across 415 distinct brain targets in 114 mice. All training data and experimental results presented in this study were acquired using a custom-built US-guided FUS system (USgFUS) operating at 0.5 MHz excitation frequency (see Methods)17. As a proof-of-concept ML model, we employed a neural network model known as multilayer perceptron (MLP) consisting of fully connected neurons with one hidden layer (10 neurons) and a sigmoid activation function (Fig. 1A). Despite being a simple model, this structure allows the model to learn complex relationships between input dataset – MB AE, for instance – and broadband emission that are difficult to capture with conventional statistical tools53. Moreover, when prior knowledge about feature relationships (i.e., MB AE vs. broadband emission) is limited or unavailable, MLPs – being a universal function approximators – offer a flexible solution compared to other ML models. We then trained the MLP model using Levenberg-Marquardt algorithm54. The inputs to the model included 12 features: primarily MB AE in the ultra-harmonic frequency range, which are considered to be closely related to inertial cavitation and brain damage40, as well as additional variables such as MB kinetics and the presence of disease (cancer) in the targeted tissue (see Table 1 for a complete list of features). Each dataset was labeled (i.e., ground truth labeling) based on whether a broadband emission event (defined as 6 dB above baseline noise) occurred in the subsequent sonication.
Figure 1. Multilayer perceptron model training, interpretation, and its integration with the controller.
A) Schematic of simple proof-of-concept MLP model with one hidden layer with 10 neurons. Input features are described in Table 1. B) Confusion matrix for MLP model training (80% of ground truth label and matched number of ground false label); Numbers in the matrix indicate the number of data points with the top left, top right, bottom left, and bottom right being true negative, false positive, false negative, and true positive, respectively. C) Schematic of ML-assisted closed-loop MB-FUS controller. MLP model’s output is used as an additional safety layer (advisory loop) to override closed-loop controller’s decisions upon positive prediction. This flexible design allows its universal compatibility with various control algorithms. D) SHAP value analysis onto MLP model. All training datasets were used for analysis without random sampling. Left shows global importance calculated from the absolute value of SHAP values. Partial SHAP analysis of single feature, pressure, shows weakly positive correlation between pressure and SHAP, but with high variance, which indicates the effect of pressure onto model is not monotonic. For the right (SHAP analysis), being closer to red indicates higher values of each feature. SHAP value (x-axis) represents the contribution of each feature’s value onto the output of the model (positive SHAP value indicates the tendency of positive broadband prediction by the model).
Table 1 –
Features and Label for MLP model training
| Feature (t = T) | Label (t = T+1) | ||||
|---|---|---|---|---|---|
| 1–7th Ultra-harmonic | Pressure | Target Location | MB Kinetics | Tumor Presence | Broadband emission >6dB |
Due to the inherent class imbalance (only 8% of total AE data contained broadband emissions) and to prevent model from being biased towards the more frequent no-broadband events, we performed under-sampling55 of the majority class (i.e., no-broadband), which in fact showed more conservative behavior (i.e., higher false positive) while attaining sensitivity (i.e., true positive rate – correct broadband emission prediction) compared to oversampling technique (Fig. S1 & Fig. S2). We then trained the MLP model using 80% of the under-sampled data and tested it on the remaining 20% (see Methods). In our training dataset, we found 94% (6,384/6,772) overall accuracy, 96% (3,244/3,386) sensitivity (true positive rate), and 93% (3,244/3,490) precision (false positive vs. true positive), and 93% (3,140/3,386) specificity (true negative rate) in predicting broadband emission events (Fig. 1B). Crucially, the retained high sensitivity in testing dataset suggests that the model remains effective at detecting true broadband emission events, which is especially important given their scarcity and potential safety implications. The low precision in testing data set (53%, Fig. S1) reflects a tendency toward false positive predictions – possibly influenced by the simplicity of our proof-of-concept MLP model. On the other hand, low precision highlights the model’s conservative behavior, which is a desirable trait in the context of clinical translation, where minimizing the risk of missing predictions is a priority. We also confirmed that other machine learning models, such as support vector machine (SVM), had comparable performance (Fig. S1 & Fig. S2). Importantly, we found that when it is necessary to improve the performance and precision (i.e., reduce conservativeness) of the model, more advanced deep learning techniques such as the Attentive Multilayer Perceptron (AMP) model are highly potent (Fig. S3 & Fig. S4, see methods and Supplementary Information for detailed design). Together, these findings highlight the potential of ML methods to identify precursor patterns of future MB collapse. By anticipating rather than reacting to these adverse events, such data-driven methods offer the potential for real-time safety monitoring during MB-FUS treatment (i.e., responding before MB collapse and associated brain damage has taken place).
Design and interpretation of machine learning-assisted closed-loop controller (ML-CL)
Design of machine learning-assisted closed-loop controller framework:
Having established the predictive potential of the MLP model, we then designed a machine learning-assisted closed-loop MB-FUS controller (ML-CL) by integrating the trained MLP model into a closed-loop controller (CL) algorithm we have recently proposed and validated17. CL algorithms operate by targeting a desired AE level (i.e., target level) and dynamically adjusting their input pressure based on real-time feedback from the current AE level, with the goal of minimizing the error between the current and target AE levels16. In this framework, on top of the CL algorithm, we implemented the MLP as an additional safety layer (Fig. 1C). This design preserves the controller’s responsiveness to broadband emission events (i.e., reactive element) while introducing an additional predictive element that enables the controller to also anticipate broadband emissions and respond as if they have already occurred. Importantly, integrating MLP as an additional safety layer does not interfere with the controller’s actions (i.e., controlling harmonic emissions) during normal operation but ensures that the MLP acts when necessary – overriding the controller’s decision upon prediction of a broadband event during sonication. Perhaps the most salient feature of this design is its flexibility, as it allows the MLP to be integrated into any controller or system (provided there is sufficient AE data for training from ongoing trials or experiments) without altering its core functionality or features. Likewise, different ML models (see Supplementary Information) can be integrated into this framework.
Interpreting machine learning models offer a data-driven approach for studying and analyzing the MB dynamics in brain vessels:
In light of the above findings, we took this analysis one step further by attempting to interpret the trained MLP model and support a data-driven analysis of MB dynamics. To interpret our MLP model, we assessed our results using Shapley Additive Explanations (SHAP) (Fig. 1D). SHAP assigns each input feature a contribution score (SHAP Values), indicating how much it influences the model’s output56 and hence enabling quantification of their importance. While the original MLP model was trained using ultra-harmonics as the MB AE features, we included both ultra-harmonics and harmonics in the SHAP analysis to evaluate the broader importance of MB AE components (see Table 2 for a complete list of features). As indicated by SHAP values, we found that the top 7 contributing input features were strongly associated with the key physical characteristics of the MB dynamics and the configuration of the USgFUS system (Fig. 1D). These were: i) the passive cavitation detector’s (PCD) peak sensitivity at 3.5 MHz, represented by 6th, 7th ultra-harmonic and 7th harmonic; ii) the MB dynamics strength and proximity to MB instabilities (i.e., bubble collapse), represented by 1st ultra-harmonic, which are unique signatures of MB dynamics and have been used in the past to control the MB dynamics and establish safety thresholds40,42; iii) the number of MBs in focal region, represented by MB kinetics; and iv) the peak negative pressure, which is a key driver of MB dynamics57. Interestingly, while lower-order harmonics are often considered more useful in practice – owing to their efficient emissions58 and effective transmission through the skull – our results suggest that the harmonics close to the receiver sensitivity (even up to 7th harmonic) exhibit similar significance. This highlights the importance of the system’s design and tuning for recording MB AE. In our preclinical system, harmonics near 3.5 MHz (7th harmonic) were shown as critical, which suggests that controlling 7th harmonic (3.5 MHz) should be prioritized with this system configuration. We anticipate that this system-specific result will be different for clinical systems, however our framework can be applied as is using data from such systems. Our analysis also revealed that the presence of tumors can elicit higher probability of broadband emissions, which is surprising as this MB behavior has not been reported in the past despite extended preclinical and clinical investigations.
Table 2 –
Features and Label for MLP SHAP Analysis
| Feature (t = T) | Label (t = T+1) | |||||
|---|---|---|---|---|---|---|
| 2–8th Harmonic | 1–7th Ultra-harmonic | Pressure | Target Location | MB Kinetics | Tumor Presence | Broadband emission >6dB |
While most features showed consistent behavior – with high (red) or low (blue) feature values pushing the model’s predictions in a clear direction, Fig.1D – SHAP analysis revealed a more complex pattern for sonication pressure. We found that while pressure was a highly influential variable, its effect on the model’s output was not monotonic. This suggests that although sonication pressure plays a key role in shaping MB dynamics, its relationship with broadband emission is likely situation dependent. That is, despite a weak positive overall correlation (Fig 1D) between sonication pressure and broadband emission, this effect can be influenced by the skull and (transient) MBs’ concentration-dependent dynamics, among others59,60. Moreover, by analyzing our training dataset, we found a close correlation between MB kinetics (5th feature of importance according to MLP’s SHAP values) and the strength of broadband emission, which suggested that stronger broadband emission likely occurs at higher (>70%) MB (transient) concentrations in the body after a bolus administration (Fig. S5). This indicates that the temporal MB dose fluctuation, in addition to the total MB dose60–63, is an important safety consideration. Together with SHAP analysis, these findings underscore the inherent risk associated with the use of constant pressure sonications (currently widely used in clinics) and further support the use of “ramping up” (closed-loop) control algorithms17. In aggregate, our results demonstrated the capability of ML model and data-driven analysis of MB dynamics to predict instabilities in their behavior (i.e., MB collapse) and uncover subtle but potentially important features that shape their highly nonlinear response in vivo.
Safety and efficacy evaluation of machine learning-assisted closed-loop FUS controller (ML-CL) in BBB opening
Evaluation of ML-CL at low exposure condition (32 dB):
To evaluate the operation of the ML-assisted closed-loop controller (ML-CL), we first performed MB-FUS mediated BBB opening in healthy mice by targeting three regions in each brain hemisphere using the USgFUS system that we used to collect the training data. We selected a target level of 32 dB at 7th harmonic emission using the cavitation threshold curve identified from our training dataset (Fig. S6A). We chose this target level because it was at the highest level within the linear (before plateauing) regime of the curve. With 32 dB target level, we found that the average and maximum pressure decisions (PAvg and PMax, reported as peak negative pressures) of ML-CL were 0.17 MPa and 0.23 MPa, respectively (Fig. S6B). Along with the pressure corresponding to 32 dB in the cavitation threshold model (PModel = 0.14 MPa, Fig. S6A), these pressures provided the necessary exposure conditions for implementing constant pressure open-loop controllers (OL) to compare and benchmark the ML-CL controller’s performance. Unfortunately, the selected target levels and exposure settings were characterized by a low incidence of broadband emission events (3 events per 1,800 pulses) and, as such, they did not allow us to fully expose their potential benefits of ML-CL and tradeoffs between safety and efficacy (see below and Fig S6). Despite their shortcomings, they allowed us to establish feasibility for the proposed methodology in predicting and preventing scarce broadband emission events (See suppl. methods and Fig S6). They also provided an upper safety limit for the conventional (i.e. reactive) control methods as well as a lower BBB opening limit (P32dBAvg).
Evaluation of ML-CL at high exposure condition (36 dB):
In subsequent experiments (Fig. 2A), we selected a 7th harmonic target level of 36 dB, which lies beyond the range of the cavitation threshold curve. The absence of representative pressure from the cavitation threshold model (PModel = N/A) indicates that the 36 dB target level presents a challenging condition for all controllers (Fig. 2B). Note that while the threshold selected is above the controller calibration curve, it is still within the distribution of the data that we used to train the MLP, which is critical for accurate predictions (i.e., no extrapolating out of distribution). Again, the OL controllers operated at the pressure levels determined by the ML-CL operation (at 36 dB target level). That was at average (PAvg) and maximum pressures (PMax) of 0.25 MPa and 0.33 MPa, respectively (Fig. 2C). We also incorporated a state of the art closed-loop controller (CL)17, operated at 36 dB target level. For each controller algorithm, we assessed the resulting AE, total broadband emission events, and BBB opening strength, as before (Fig. 2D–E). While in this condition, we found no significant difference in AE levels achieved among controllers (i.e., presumably due to AE saturation as observed in Fig. 2B), closed-loop control algorithms CL and ML-CL exhibited significantly lower AE fluctuation compared to the OL throughout the sonication (Fig. 2F), which reflects their ability to consistently maintain certain level of MB dynamics. Similar to AE, Ktrans values indicated comparable BBB permeability across all groups (Fig. 2G–H), except for PAvg and CL. The lack of significant difference between the groups is likely due to the high variance observed in the Ktrans for OL group, which may stem from its corresponding variability in AE. Importantly, when we assessed the presence of broadband emission events, we found that OL controllers operated at PAvg and PMax resulted in 1.05% (11/1048) and 4.39% (46/1048) of sonications with broadband emissions, respectively (Fig. 2I, orange and red). Interestingly, CL group also showed a notable presence of broadband emission events in 1.34% (14/1048) of sonications, indicating that 36 dB target level not only represents a limiting condition for OL control algorithms but for all the controllers (including CL) that react to the broadband events (Fig. 2I, orange, red, and green). In contrast, the proposed ML-CL algorithm recorded only one instance of broadband emission event (1/1048, less than 0.1%), representing a 93% reduction compared to the CL algorithm (Fig. 2I, blue). This reduction is likely due to the MLP algorithm’s predictions during ML-CL operation, with 4.4% (46/1040) of its sonications flagged as potential broadband emission events (Fig. 2J). This is almost 20-fold higher prediction rate compared to 32 dB target level (Fig. S6I), highlighting the versatility of ML-CL and its ability to maximize the controller’s efficiency while maintaining a strong safety profile. Furthermore, applying MLP to the OL algorithms’ post-operation AE revealed that it could have predicted 51% of OL’s broadband emission events (Fig. S7).
Figure 2. Performance assessment of ML-CL under limiting conditions.
A) General MB-FUS experiment procedure for all controllers. B) Cavitation threshold model from the training dataset. 7th harmonic AE as a function of pressure. To assess the controllers’ performance at their limits, we selected a target level above the model (36 dB). C) ML-CL pressure decisions for 36 dB target level (left). The average and maximum pressures used by ML-CL were used to determine PMax and PAvg for OL controllers (right). A decrease in pressure in OL indicates a reaction to broadband emission events (> 6 dB). D) Representative MRI image for 36 dB target level sonication targets. 2 targets in each brain hemisphere (total 4 targets per mouse) were treated. E) 7th harmonic emissions during sonication for each controller. PAvg : 36.2 ± 3.3 dB, PMax 37.9 ± 2.4 dB, CL : 35.1 ± 0.7 dB, ML-CL : 34.7 ± 0.7 dB. n = 8 targets (total 2 animals) per group. F) Mean (left) and standard deviation (right) of 7th harmonic emission during sonication by ML-CL. A variance test (f-test) was performed to compare standard deviation (right) of the mean 7th harmonic emission at each target. G) MRI T1 images using the controller at 36 dB or equivalent OL pressure. H) Quantification of Ktrans values through DCE-MRI. I) Histogram for broadband emission levels during sonication. Broadband emissions higher than 6 dB were considered a broadband emission event, whose probability for each controller is highlighted next to the dotted line. Percentages indicate 11, 46, 14, and 1 instances of broadband emission event out of 1,048 total sonications for PAvg, PMax, CL, and ML-CL, respectively. J) Histogram for MLP decision during ML-CL sonication. A model output of 0.5 or greater was considered a positive prediction. For this target level (36 dB), the model predicted 4.4% (46/1040) of sonication. K) Treatment window analysis for reactive (OL, CL) and predictive (ML-CL) controllers. Bottom left: mean pressure vs. Ktrans at each target. Black indicates OL and CL, blue indicates ML-CL, and red indicates where broadband emissions were present. Top: pressure vs. broadband level throughout all sonication AE datasets. A more detailed figure with individual data points is shown in Fig. S8. ML-CL treatment window: 0.09 MPa (0.17 to 0.26 MPa). This was approximately a 300% increase (green area) from OL and CL’s treatment window: 0.02 MPa (0.17 to 0.19 MPa). Upper bounds for treatment windows were selected according to the inflection point of the hyper tangent curve fit, which indicates an increased likelihood of broadband emission. †The pressures (x-axis) used for the top left plot are the mean pressure at each targe brain location, and the pressure (x-axis) used for the bottom left plot is real-time pressure at each sonication similar to B (see Fig. S8). Also, for this figure, sonication data (Ktrans and AE) from later parts of the study were included, which adds 1 additional broadband emission event for ML-CL. Bottom right: the probability of having broadband emission event vs. Ktrans. ML-CL improved Ktrans given the same probability of broadband emission probability as evidenced by a shift in the curve by 188% (green area under hyper-tangent curve, the inflection point of 0.0173 to 0.0499). ns = not significant, *p<0.05, **p<0.01, ***p<0.001, and ****p<0.0001. Statistical analyses were performed through One-way ANOVA and Bonferroni correction. For the variance test, f-test was used with Bonferroni correction.
Subsequently, to determine treatment window improvement by ML-CL, we gathered the sonication data (e.g., pressure and broadband levels) from the reactive (OL, CL – i.e., No ML) and predictive (ML-CL) controllers and their resulting Ktrans (Fig. 2K). We defined 0.17 MPa (P32dBAvg) as a conservative lower bound of the treatment window, as the Ktrans rose above the background at this pressure (Fig. S6G). We then defined the upper bound of the treatment window as the pressure that resulted in a notable increase in broadband emission levels (i.e., point of inflection: 0.19 MPa for reactive controllers; 0.26 MPa for ML-CL). Strikingly, such pressure-bound analysis indicated that the ML-CL expanded the acoustic treatment window by 4-fold, from 0.02 MPa to 0.09 MPa (Fig. 2K, top). Moreover, by performing a similar analysis of Ktrans and broadband emission event probability (Fig. 2K, bottom right), we found ML-CL achieved 3-fold increase in BBB permeability in healthy mice brains given the same risk of brain injury compared to reactive controllers (Fig. 2K, bottom right). Collectively, our results demonstrate that the integration of ML in MB-FUS mediated BBB opening control algorithms quadruples the treatment window, leading to improved BBB opening for a reduced risk of MB collapse (i.e., maximum benefit/risk ratio).
Safety confirmation of ML-CL at high exposure condition (36 dB):
Lastly, to directly assess the ability of ML-CL on preventing tissue damage, we examined the brain tissues sonicated with 36 dB target level using H&E staining (Fig. 3A). We found that all the MB-FUS target locations that were sonicated with the OL controllers (PAvg or PMax) with broadband emission events had either visible or H&E-evidenced hemorrhages (i.e., petechiae) (Fig. 3). Similar responses were observed with the CL group although we identified petechiae at 2 (out of 8) targets where the broadband emission was undetected (Fig. S9). ML-CL group showed hemorrhage only at the one target where a broadband emission event was detected (Fig. 3A, bottom right). In a separate cohort, we sacrificed the animals 6 hours post sonication and stained the brains for astrocytosis (GFAP) and microglial activation (Iba-1), which are established markers for assessing neuroinflammation64–66. We found that compared to the contralateral unsonicated region, PAvg group showed an increase in GFAP expression (Fig. 3C, top), indicating early signs of astrocytosis in response to sonications. ML-CL revealed no significant increase in the GFAP expression, highlighting its ability to maintain safety. At this time point we did not observe differences in Iba-1 expression in either group. The observed lower expression of Iba-1 compared to GFAP expression is consistent with previous findings65. Together our findings confirm that broadband emission events are key indicators of brain damage and demonstrate that integrating ML (i.e., predictive element) into a closed-loop controller can persistently and proactively ensure safety and consequently expand (4-fold) the treatment window of MB-FUS mediated BBB opening.
Figure 3. ML-CL can enhance safety without compromising BBB opening efficiency.
A) H&E staining at each target referenced in photos of brain slices in the middle. B) Representative immunofluorescence images of GFAP and Iba-1. C) Quantification of GFAP and Iba-1 intensity comparing contralateral region and sonicated region. GFAP expression showed a significant increase (*p<0.05) in PAvg group but not in ML-CL. No differences in Iba-1 were observed. Paired t-tests were used for statistical analysis. ns = not significant, *p<0.05.
ML-CL augments the safe and efficient delivery of PEGylated polystyrene nanoparticles
Following the evaluation of ML-CL and establishing exposure conditions for robust BBB opening without compromising safety, we assessed the impact of the widened treatment window using ML-CL to deliver fluorescently labeled PEGylated polystyrene nanoparticles (NPs) of different sizes (37, 46, and 120 nm after PEGylation; detailed characterization shown in Table 4)67. We sonicated healthy mice at one posterior and one inferior region on each brain hemisphere, where left and right hemispheres were sonicated with ML-CL operating at 32 dB and 36 dB, respectively (Fig. 4A). Immediately after sonication, we intravenously delivered NPs and analyzed the resulting delivery using IVIS (Fig. 4B). During sonication (Fig. S10 A–B), we observed only one instance (1 out of 1048 total sonications) of broadband emission event at 36 dB target level (one target from the 120 nm group, Fig. S10 C). Hence, we deduced that the safety profile was comparable to our previous investigations (Fig. 2 & Fig. 3). Moreover, our analysis of Ktrans (Fig. 4C) supported previous observations that indicated a target-level-dependent increase in BBB permeability in healthy brains. In agreement with the levels in AE and Ktrans, we observed enhanced NP delivery by 2.8-fold, 2.1-fold, and 2.1-fold for 37, 46, and 120 nm sizes, respectively (compared to non-sonicated regions – Fig. 4D; 36 dB targets). While the data had significant variation, presumably due to IVIS assessment (i.e., lower detection sensitivity for deeper targets), the NP delivery was significantly higher (p < 0.05) only for the 36 dB sonication. This indicates that the improved treatment window by ML-CL is critical for improving NP (up to 120 nm) delivery in the brain. We also investigated the size dependency of in vivo NP delivery by accounting for size-dependent total radiance (Fig. 4E–F). Interestingly, we found that 46 nm had maximum delivery (Fig. 4G). While these data seem counterintuitive, they support past studies that have shown that the delivery of NPs in the range of 40–50 nm is optimal after MB-FUS68. In aggregate, these findings demonstrate the ability of ML-CL to significantly enhance the delivery of NPs in the murine brains without compromising safety by critically expanding the treatment window of MB-FUS.
Table 4 –
PEGylated polystyrene nanoparticle characterization
| NP Size | Number Average (nm) | Zeta Potential (mV) |
|---|---|---|
| 37 nm | 36.94 ± 4.73 | −2.91 ± 1.21 |
| 46 nm | 46.13 ± 2.54 | −2.04 ± 1.03 |
| 120 nm | 119.87 ± 2.18 | −2.64 ± 1.41 |
Figure 4. By expanding the treatment window ML-CL can safely enhance delivery of PEGylated polystyrene nanoparticles with broad size distribution in healthy brain.
A) Representative T1-MRI image after ML-CL sonication. Left brain hemisphere was treated with 32 dB, and right brain was treated with 36 dB ML-CL. n = 2 animals (total 4 targets) per group. B) Representative IVIS imaging showing delivery of each size NPs at ML-CL targets. Color range is formulated in logarithmic scale. C) Quantification of Ktrans for each target level. Both 32 and 36 dB target levels resulted in significantly higher Ktrans compared to unsonicated region (p<0.0001). 36 dB group had higher Ktrans compared to 32 dB group (p<0.001). Statistical analysis was performed through one-way ANOVA with Bonferroni correction. D) Quantification of IVIS fluorescence for each size NPs. 36 dB group increased 37, 46, and 120 nm NP delivery by 2.8, 2.1, and 2.1-fold, respectively (*p<0.05). Statistical analysis was performed using one-way ANOVA with Bonferroni’s correction. E) Representative image of in vitro IVIS setup with the different NPs (injection concentration) on a well plate (see Methods for details). F) We used the normalized in vitro radiance from each NPs to account for differences in their in vivo fluorescence. G) Normalized quantification of D using in vitro fluorescence ratio. ns = not significant, *p<0.05, **p<0.01, ***p<0.001, and ****p<0.0001. Statistical analyses were performed through One-way ANOVA and Bonferroni correction.
ML-CL augments the release of brain cancer soluble biomarkers to the circulation
Subsequently, using tumor-bearing GL-261 mouse models, we assessed the ability of the ML-CL controller to augment the release of soluble biomarkers into the circulation. In this proof-of-concept investigation, we transduced the GL-261 cell line with Gaussia Luciferase (GLuc), so they can release a luminescent protein69,70. This allows us to concurrently compare the release of GLuc protein (~ 20kDa) and gene (~ 60kDa)71,72 with high specificity. We sonicated the GL-261-GLuc tumor-bearing mice using ML-CL (32 or 36 dB target level) and collected blood pre- and post-treatment (Fig. 5A). For non-sonicated control group (i.e., MB only; No FUS), we followed the same blood collection protocol. We chose 32 or 36 dB ML-CL target levels based on the NP delivery experiments, where the former represents a conservative exposure (i.e., close to current safety levels) and the latter can consistently improve the transport of large molecules across the BBB (Fig. 4). The tumor sizes were evenly distributed among the groups (Fig. 5B–C), and treatment groups were sonicated in 5 locations across the tumor; this sonication protocol (multiple-targets to cover tumor) was employed in all subsequent experiments involving tumor-bearing rodents.
Figure 5. ML-CL augments the release of brain cancer-soluble biomarkers.
A) Experimental procedure indicating the time points for treatment and blood collection. The control group was injected with MB only as treatment. B) Representative T2-MRI images for tumor, GL-261-GLuc. C) Tumor size distribution across groups. All groups had no significantly different tumor size distribution. (n = 4, control, n = 4, 32 dB, n = 6, 36 dB, respectively). D) Transient 7th harmonic emission of 32dB (light green) and 36 dB (green) ML-CL during its application on GL-261-GLuc tumor-bearing mice. E) Distribution of 7th harmonic emission for ML-CL at 32 dB and 36 dB target levels. 7th harmonic level distribution was compared with t-test. (32 dB – 30.96 ± 3.13 dB; 36dB – 34.57 ± 3.73 dB). F) Histogram of broadband emission during sonication. 32 dB ML-CL had 0.04% (1/2620), and 36 dB had 0.17% (8/4585) of sonication that contained broadband events. G) ML model output during sonication. The model predicted broadband emission at 1.8% (48/2620) and 15.8% (722/4585) of 32dB and 36 dB ML-CL sonication, respectively. H) ML-CL target locations. I) Representative MRI-T1 images and J) quantification of Ktrans. K) GLuc protein luminescence quantification. Mean relative change – Control group: no difference (ns), 32dB: 2.2-fold (ns), 36 dB: 3.1-fold (p<0.05). L) GLuc gene quantification. Mean relative change – Control group: no difference (ns), 32dB: 1.5-fold (ns), 36 dB: 7.8-fold (ns). ns = not significant, *p<0.05, **p<0.01, ***p<0.001, ****p<0.0001. All statistical analyses were performed using One-way ANOVA with Bonferroni correction. Specific samples were excluded, check methods for exclusion criteria.
Interstingly, we found that the average harmonic target level achieved by ML-CL (34.57 ± 3.73 dB) was lower than in healthy brain study (35.1 ± 0.7 dB) (Fig. 5D–E). While this is somehow surprising, it is nevertheless consistent with our observations during SHAP analysis of the MLP, which suggested that the presence of a tumor drives the model towards positive predictions (Fig. 1D), which activates the MLP and forces the controller towards lower pressures and consequently towards lower harmonic levels. In fact, while we saw similar probability of broadband emissions compared to healthy brain (0.17% vs. 0.1%) (Fig. 5F), we also observed an increase in total predictions made by MLP (15.8%) in the presence of tumor as compared to healthy brain (4.4%) (Fig. 5G), further corroborating the SHAP analysis. These results highlight ML-CL’s versatility and robustness to different biological environments of tumor-bearing mice.
As evidenced by the increase in Ktrans, non-sonicated control tumors were leakier than contralateral healthy brains. However, after ML-CL operation on tumors (Fig. 5H), there was a significant increase in BBB permeability in sonicated tumors as compared to control group tumors (Fig. 5I–J). Crucially, we found that only for ML-CL operating at 36 dB, the GLuc protein concentration in the blood significantly increased (3.1-fold) immediately after sonication (p<0.05) (Fig. 5K). This suggests that, similar to therapeutic agent delivery, release of tumor-soluble macromolecules require the higher exposure conditions that only the ML-CL can attain without compromising safety. Meanwhile, although these GLuc protein levels persisted after 2 hours, a declining trend was evident (Fig. S11), suggesting a burst release immediately after BBB opening. In contrast to GLuc protein, GLuc gene analysis showed that the levels of positive droplets in the circulation were very low and inconsistent for all groups (Fig. 5L), indicating insufficient amount of DNA fragments in the collected blood. While the analysis of the smaller and more abundant GLuc protein consistently demonstrated the critical role of BBB permeability in restricting the release of cancer soluble biomarkers, the lack of GLuc gene in our analysis highlighted several challenges in addition to BBB permeability. These are possibly related to the degradation of ctDNA71 in the circulation, assay sensitivity, or sampling issues related to the relatively low blood volume collection limit allowed for mice. To address the impact of these factors on the detection limit and decipher the role of BBB permeability on ctDNA detection, we decided to conduct experiments in larger animal models (see below).
ML-CL improves the delivery of nanoparticles in glioma tumors in rats
To assess the robustness and scalability of the ML-CL framework and its ability to widen the treatment window, we scaled it up to rats – an inherently more challenging model due to a thicker skull and different MB clearance kinetics – and compared its performance against an open-loop controller operated at PAvg. Following the experimental protocols similar to those used in mice (Fig. 6A–C), we sonicated F98 tumor-bearing (SRG) rats with 7 non-overlapping locations with either ML-CL or PAvg. For ML-CL, we conservatively chose a target level of 33.5 dB to account for thicker skulls, and a corresponding PAvg of 0.29 MPa was determined from ML-CL operation (Fig. 6B). In these experiments, we were intravenously delivered 46 nm NPs at a dose of 5 mg/Kg after sonication. Note that the minimum operation time for controller (i.e., MB kinetics recording) was increased to 40 seconds as compared to 20 seconds in mice to accommodate for the faster MB kinetics in rats.
Figure 6. ML-CL augments delivery of PEGylated polystyrene nanoparticles in F98 tumor-bearing rats.
A) Experimental procedure indicating the time points for treatment, NP administration, and IVIS analysis. The control group (no FUS) was injected with MB only as treatment. B) Representative MRI-T2 image for F98 tumor and sonication target locations. C) Tumor size distribution across groups. All groups had no significantly different tumor size distribution. (n = 5, control, n = 5, PAvg, n = 5, ML-CL 33.5 dB, respectively) D) Transient 7th harmonic levels during treatment (Blue: ML-CL 33.5 dB; Orange: PAvg 0.29MPa). Note that the curve is average of all targets, where MB arrival time and rise time can be different, that led to lower averaged harmonic level. E) Histogram of 7th harmonic levels for PAvg (Orange) and ML-CL 33.5 dB (Blue). 7th harmonic levels during 20 seconds following MB arrival were considered for all sonication. 30.8 ± 4.0 dB for ML-CL; 24.7 ± 10.9 dB for PAvg. Levene’s test was used for variance comparison and t-test for mean comparison. Sk = skewness. F) Histogram of broadband emission during sonication. PAvg (Orange) had 0.76% (35/4585), and ML-CL (Blue) had 0.24% (11/4585) of sonication that contained broadband events. G) ML model output during sonication. The model predicted broadband emission at 10.03% (460/4585) of ML-CL sonication. H) Representative MRI-T1 images and I) quantification of Ktrans. J) Representative IVIS image of NP delivery in F98 tumor-bearing rats. Left: Control (no FUS); Middle: PAvg (0.29 MPa); Right: ML-CL (33.5 dB target level). K) Quantification of NP delivery. ML-CL improved NP delivery by 7.2-fold (p<0.001) compared to control group and 2.8 -fold (p<0.01) compared to PAvg group. ns = not significant, *p<0.05, **p<0.01, ***p<0.001, ****p<0.0001. All statistical analyses were performed with One-way ANOVA with Bonferroni correction.
Interestingly, we observed that compared to PAvg, ML-CL achieved a higher mean harmonic level (30.8 ± 4.0 dB vs. 24.7 ± 10.9 dB – Fig. 6D–E) and actively shaped its distribution, resulting in a mildly left-skewed profile (skewness = −0.4) with lower standard deviation (10.9 dB vs. 4.0 dB; p<0.0001, Levene’s test; Fig. 6D–E). This suggests that in contrast to PAvg, ML-CL overcomes weak therapeutic activity and modulates harmonic emissions clustering towards higher values with consistency, thereby highlighting its ability to effectively scale its performance and adapt to different (larger) animal models. Importantly, both controllers maintained comparable and low broadband emission probability (0.76 % vs. 0.24% for PAvg and ML-CL, respectively; Fig. 6F). The MLP model exhibited consistent behavior in rats as it did in mice (Fig. 6G), demonstrating that ML-CL’s safety performance can be scaled to larger animal alongside its controlling capability.
Our analysis of BBB permeability using Ktrans values corroborated our observations in harmonic level distribution: permeability increased progressively from the control group (untreated) to PAvg group and was highest in the ML-CL group (Fig. 6H–I). Surprisingly, despite this trend in Ktrans – which also revealed the leaky nature of untreated tumors compared to healthy brain region (Fig. 6I) – we observed a notable difference in actual NP delivery. Specifically, NP delivery was negligible in the control group but significantly enhanced only by ML-CL, achieving a 7.2-fold and 2.6-fold increased delivery compared to the control group and PAvg (Fig. 6J–K), respectively. This not only suggests that AEs’ may better predict larger molecule delivery in brain tumors than Ktrans (i.e., maps the small molecule gadolinium permeability) but also re-emphasizes the potential of ML-CL to reliably and safely maximize therapeutic outcomes. Collectively, these findings demonstrate that ML-CL can be scaled to larger animal models while maintaining its performance (i.e., maximizing the BBB permeability while preventing broadband events) and ability to improve NP delivery in brain tumors.
ML-CL augments the release of ctDNA into circulation from glioma tumors in rats
Finally, using F98 tumor-bearing rat models, we evaluated the ability of ML-CL controller to improve the release of GLuc protein and gene into the circulation. Compared to mice, rats permit the collection of larger blood samples that allow us to assess its impact on the detection of GLuc protein and gene. In addition to increased blood volume, here we also employed a pre-amplification step via nested-PCR technique to further improve the sensitivity of the assay. Similar to our mouse study, we transduced the F98 cell line with Gaussia Luciferase (GLuc) and quantified its protein and gene levels in the blood. As before, we sonicated the F98-GLuc tumor-bearing rats using PAvg and ML-CL and collected blood pre- and post-treatment (Fig. 7A). For non-sonicated control group, we injected MB only (No FUS) with same blood collection protocol. We maintained tumor-sonication protocol similar to NP delivery study (Fig. 7B–C). For ML-CL target level, we chose the same (33.5 dB) as in our NP delivery, where PAvg was found to be 0.30 MPa. For these experiments we chose immunocompetent rat strain (CDF), as it represents a more challenging and clinically relevant model (i.e. rapid clearance and degradation of biomolecules in the circulation). The implementation of the immunocompetent rats leads to lower biomarker concentration baseline73,74 (pre-FUS), which demonstrates more realistic impact of FUS on molecule release (Fig. S12).
Figure 7. ML-CL augments release of protein and ctDNA from F98-GLuc tumor-bearing rats.
A) Experimental procedure indicating the time points for treatment and blood collection. The control group (no FUS) was injected with MB only as treatment. B) Representative MRI-T2 image for F98-GLuc tumor and sonication target locations. C) Tumor size distribution across groups. All groups had no significantly different tumor size distribution. (n = 6, control, n = 6, PAvg, n = 8, ML-CL 33.5 dB, respectively) D) Transient 7th harmonic levels during treatment (Blue: ML-CL 33.5 dB; Orange: PAvg 0.30 MPa). Note that the curve is average of all targets, where MB arrival time and rise time can be different, that led to averaged down harmonic level. E) Histogram of 7th harmonic levels for PAvg (Orange) and ML-CL 33.5 dB (Blue). 7th harmonic levels during 20 seconds following MB arrival were considered for all sonication. ML-CL: 28.2 ± 5.6 dB and PAvg: 26.8 ± 6.6 dB. Levene’s test was used for variance comparison and t-test for mean comparison. Sk = skewness. F) Histogram of broadband emission during sonication. PAvg (Orange) had 0.44% (24/5502), and ML-CL (Blue) had 0.98% (72/7336) of sonication that contained broadband events. G) ML model output during sonication. The model predicted broadband emission at 8.52% (460/7336) of ML-CL sonication. H) Representative MRI-T1 images and I) quantification of Ktrans. J) GLuc protein luminescence quantification. Mean relative change – Control group: 1.1-fold (ns), PAvg: 1.4-fold (ns), 36 dB: 1.5-fold (p<0.05). Left: Control (no FUS); Middle: PAvg (0.30 MPa); Right: ML-CL (33.5 dB target level). K) GLuc ctDNA quantification. Mean relative change – Control group: no difference (ns), PAvg: no difference (ns), 36 dB: 2.1-fold (p<0.01). ns = not significant, *p<0.05, **p<0.01, ***p<0.001, ****p<0.0001. All statistical analyses were performed with One-way ANOVA with Bonferroni correction. Specific samples were excluded, check methods for exclusion criteria.
Consistent with our previous findings, compared to PAvg, ML-CL produced a left-skewed (skewness = −0.7 vs. 0.41; Fig. 7D–E) and tighter (5.6 vs. 6.6 dB standard deviation; p<0.001; Levene’s test) harmonic distribution with higher mean (28.2 ± 5.6 vs. 26.8 ± 6.6 dB dB), reflecting its ability to control and maintain elevated and consistent harmonic levels, as compared to PAvg. Interestingly, unlike in the NP delivery study, PAvg showed reduced harmonic emission variance, presumably due to smaller size and decreased skull thickness of this rat strain. Nonetheless, our results highlight the inherent shortcomings of open-loop (constant-pressure) controllers which are prone to instabilities in their harmonic emission such as i) right-skewed distribution – likely due to the early influx of MBs after bolus injection – that by nature contributes to lower mean and ii) higher variability in distribution. Importantly, given that both PAvg and ML-CL showed less than 1% chance of broadband emission event, our results demonstrated that ML-CL’s safety performance is also robust to biological variability introduced by different strains.
Our analysis of BBB permeability using Ktrans values, however, did not reflect our observations in the harmonic level distribution: while permeability increased progressively from the control group (untreated) to PAvg group, ML-CL group’s permeability was not significantly different from PAvg (Fig. 7H–I). Surprisingly, despite this lack of trend in Ktrans analysis, which quantifies the permeability of the much smaller MRI contrast agent, we observed a striking difference in the release of the reporter protein and gene, re-emphasizing the limitation of smaller size molecules (gadolinium) to fully represent the pharmacokinetics of larger size molecules (protein and gene). We observed significant improvement of biomarker release for both protein and ctDNA only for ML-CL group (1.5-fold for protein and 2.1-fold for ctDNA, Fig. 7J–K). This further underscores the importance of maximizing AE to improve biomarkers’ release – which is an effect that ML-CL can uniquely achieve while maintaining safety. It also confirmed that collection of larger blood volumes is critical for effective ctDNA detection. ctDNA degradation and clearance appear to be of lower significance, as long blood collection is close to sonication. In aggregate, these findings demonstrate that ML-CL, trained in mice, retains its safety and efficacy in tumor-bearing rats, hence revealing its translational potential for clinical diagnostic applications with FUS-enhanced liquid biopsy.
Discussion
In this work, we developed and evaluated a data-driven closed-loop ultrasound nanotheranostic platform for transcranial interventions (Fig. 1). The proposed approach critically expanded the current state-of-the-art controllers (OL and CL) by integrating ML to markedly improve the treatment window and overcome rate-limiting barriers to the delivery of nanoparticles and detection of circulating-tumor DNA from the brain. Contrary to current practice75,76, our findings indicate that the MB administration protocol is a major safety variable. Even under sonication settings that are generally considered safe under MB infusion, bolus administration can pose a significant risk, as the likelihood of broadband events can be substantially higher during the first pass of MB cloud – an effect that current simple (constant-pressure) clinical OL controllers cannot easily accommodate16,40,76,77 unless they dramatically reduce the treatment window. Furthermore, OL controllers (constant-pressure) are prone to inconsistencies in harmonic emissions, including high variability (Fig. 6E) and a tendency towards overshooting (right-skewness; Fig. 7E), both of which are intensified by focal pressure uncertainties introduced by the skull. While in that respect CL controllers are more advantageous by adapting to real-time AE, they require careful target AE level selection16,17,39 that makes them sensitive to cavitation threshold measurements. They are also bound to low target levels to avoid triggering broadband emissions (Fig. 2I). The proposed data-driven ML-CL platform overcomes these limitations. The ability to select target AE level, using a training dataset obtained from past sonications, and ability to predict broadband events makes the proposed data-driven closed-loop ultrasound platform not only immune to these fundamental tradeoffs in controlling MB dynamics but also able to scale to larger animal models. Together these advantages demonstrating the potential of data-drive feedback to be integrated into current clinical systems, provided there is sufficient data for training (e.g., current clinical systems already have these data37) and, as such, can have an immediate and far-reaching impact on targeting CNS diseases.
Beyond the clinical implications of the proposed framework, by interpreting the trained MLP model (including additional harmonic components for broader perspective) it is possible to identify new or important features that shape MB dynamics, using model interpretation techniques such as SHAP approach. This can be used to enrich existing features for controlling the MB dynamics (e.g., ultra-harmonics and harmonics). It also revealed that the likelihood of inertial cavitation is greater when sonicating brain tumors, presumably due to higher MB accumulation or possibly due to abnormal vessel structure and mechanical properties. This finding indicates that calibrating the sonication settings in healthy brains and then applying them to diseased tissues can impact the MB dynamics in unexpected ways (inertial vs. stable cavitation) to undermine safety and confound mechanistic investigations that explore specific (immuno)mechanobiological interactions78. It further underscores the importance of accounting for biological variability36,79 and conducting systematic investigations for establishing treatment windows in disease models16. SHAP analysis also revealed that pressure, while being a feature of high importance, its effect on the model’s output – hence, MB dynamics – is not monotonic (i.e., clear direction). That is, despite a weakly positive correlation, its effect on the model is likely to be influenced by complex interactions involving other MB AE features. Data-driven closed-loop ultrasound can help refine these findings and also support formal parametric analysis aimed at optimizing the FUS pulse sequences (excitation frequency, pulse duration, pulse repetition frequency) and MB properties for promoting desirable bioeffects60,80,81. Collectively, our study demonstrates that machine learning models and data-driven analysis can form the basis for studying and analyzing the highly nonlinear and complex nanoscale microbubble dynamics in brain vessels, in addition to allowing for effective control of this highly nonlinear physical phenomenon.
Our investigation also demonstrated that the marked improvement in the therapeutic window of MB-FUS can have important implications for a wide range of therapeutic and diagnostic interventions in the brain. Most notably, as the ability to safely deliver a range of NP sizes (36 – 120 nm) can create new opportunities for targeting brain diseases and potentiate systemically administered novel gene editing nano-systems that incorporate larger and more potent cargos, thereby allowing them to effectively target a broad range of CNS diseases21. Our analysis, which supported prior theoretical prediction that indicated higher delivery for 46 nm NPs under MB-FUS (Fig. 4G)82, can be further explored to study other NP variables (e.g., surface charge, coating, loaded molecule(s)) that are critical for effective delivery in the brain. Moreover, considering that the AE levels were able to track the delivery of NPs across different species, can potentially alleviate the need for MRI verification and its significant logistic burden to the treatment. Thus, AI-powered ultrasound systems may support daily/weekly treatments, potentially at an outpatient and/or in limited resource settings, without compromising performance, thereby allowing the rapid and broad dissemination (i.e., similar to US imaging) and effective clinical translation of this transformative technology16,28,47,48.
The level of robustness and flexibility offered by the proposed AI-powered ultrasound system can potentially be even more important for supporting FUS-enhanced liquid biopsy, where safety and portability can be crucial28. Our study also revealed some important principles for the integration of FUS with liquid biopsy. Most notably, it clearly demonstrated the critical role of BBB permeability in restricting the release of cancer-soluble biomarkers. It also highlighted that protein based biomarkers (i.e., GLuc protein) that are characterized by low molecular size (~20 kDa)83 and high biomarker release per cell84 are easier to detect. Unfortunately, GLuc DNA release was limited in mice. Several factors may have contributed to the limited detection of ctDNA in mice, including i) the larger size of this molecule (~60kDa)71,72, ii) the low number of copies (2 copy-limit per cell)85, and iii) challenges associated with sample collection and assay sensitivity72,86,87. However, as we showed in rats i) maximizing treatment window, ii) improving the assay sensitivity, and iii) increasing the blood collection volume (6.25x larger) are essential for improving ctDNA detection without compromising safety. Collectively, AI-powered ultrasound opens opportunities for repeated sono-interrogation of brain diseases using ctDNA and may provide a simple and economical way to confirm BBB opening independent from contrast-enhanced MR imaging. The improved performance observed at larger animals also suggests that scaling-up to humans can potentially lead to better responses, thereby creating further opportunities to genotype brain tumors and monitor the biology of therapeutic responses.
Methods
In vivo experiments:
All animal procedures were performed according to the guidelines of the Public Health Policy on the Humane Care of Laboratory Animals and approved by the Institutional Animal Care and Use of Committee of Georgia Institute of Technology. 8–12 weeks old female C57BL/6J mice (Jackson Laboratory) were used in this study (N = 37 mice in total, and 114 mice in training dataset).
USgFUS system:
The system used in this study is a custom-built portable system that operates in two different modes: imaging mode and treatment mode.
In imaging mode, the system creates a 2D ultrasonic image by raster scanning (30 mm × 30 mm window) using the US imaging probe (Imasonic) that is coaxially aligned with the FUS transducer. To guide the FUS transducer to a target location in the brain, we overlay the 2D ultrasonic image onto MRI image using the eyes as a landmark. Desired target coordinates are determined relative to the center of the line connecting two eyes. After the relocation of the FUS transducer to such target coordinates, a pulse/echo scheme is used to align the ultrasound focus to the desired depth in the brain (relative to the skull) by determining the ultrasound travel time to the skull with sound speed of 1540 m/s. The targeting accuracy of this system is ± 500μm.
In the treatment mode of the USgFUS system, the imaging probe operates in passive mode and serves as a passive cavitation detector during BBB opening. When in passive mode, the recorded signal (11ms long) by the transducer is high pass filtered (cutoff 0.6 MHz) before it is fed to data acquisition system (Model 5000D, Pico Technology) and analyzed using FFT from the host computer. The FUS transducer (Sonic Concept) is driven by sinusoidal signal (0.5 MHz f0; 10 ms pulse length; 1 Hz PRF) generated by a function generator (Picoscope, Pico Technology), which has been amplified by a 50 dB power amplifier (Model 240L, Electronics & Innovation Ltd). The peak negative focal pressure of the FUS transducer in the water (free field) was determined using a calibrated hydrophone (2mm Model, Precision Acoustics).
The frequency bin we used for measuring broadband was 3.61 ± 0.3 KHz (7.22 f0), as this was closest to the maximum sensitivity of the PCD (3.5 MHz). The frequency range for ultra-harmonic and harmonic were determined as 0.5n multiples to f0 ± 0.3 KHz (where n is 3,4,5, …).
Design of closed-loop AE controller for BBB opening:
To attain a consistent level of MB dynamics, we incorporated a closed-loop controller that we have developed and validated in our previous studies17. The controller has 3 main functions; it 1) mitigates for local AE fluctuation, 2) aims to achieve a target AE level (Lktarget; k depicts kth harmonic) of a predefined observer state (k=7 in this study, which we selected from ML feature reduction), and 3) mitigates for global AE decay (MB kinetics).
The controller is also able to track cerebrovascular MB kinetics using the MB tracking pulse, Ptracker. MB kinetics tracking allows an effective time window for controller’s operation. To prevent controller’s divergence caused by cerebrovascular MB clearance, we employed a MB tracking algorithm that monitors the MB kinetics after they are injected into the animals. The MB tracking pulse is a constant, low-pressure pulse (0.5 MHz; 10 ms pulse length; 1 Hz PRF; 60 kPa peak negative pressure) that follows the preceding controlled pressure pulse. The pressure for this pulse was chosen by selecting a pressure that resulted in minimal effect on BBB permeability, which was assessed using contrast-enhanced MRI. We have established criteria for controller’s operation: 1) when this MB tracking pulse detects 10 dB rise (relative to background signal) in 4th harmonic (H4) level, controller is turned on; 2) after controller’s being turned on, initial slope of MB clearance is monitored for 40 s and is updated in real-time after the initial recording; 3) when the calculated slope indicates 20% decay from normalized maximum H4 level, the controller is ceased, and therapeutic pulse is maintained at its latest calculated pressure until the end of the sonication (130 Sec). For consistency, this Ptracker was also incorporated in all OL controllers in this study that started the controller operation with 10 dB rise in 4th harmonic level.
Machine Learning model training and testing:
To establish a machine learning model for broadband emission prediction, a training dataset was formed using past AE data that utilized constant pressure sonication from total of 114 mice (10 ms pulse length, 1 Hz pulse repetition frequency, 0.5 MHz sonication frequency, 130s sonication). In order to find the relationship between current timepoint (tn) sonication to future timepoint (tn+1) broadband emission, features (i.e., input to machine learning model) were initially selected to be the current (tn) 1~7th ultra-harmonic (1.5~7.5f0) emission levels, target region in the brain (x and y coordinates referenced to the eyes), pulse number, MB kinetics, pressure, and presence or absence of tumor (Table 1) – 2~8th (2~8f0) harmonic emission levels were included for Shapley value (SHAP) analysis. Consequently, a label (i.e., ground truth for supervised classification machine learning) was selected to be binary presence of broadband emission (6 dB above baseline) at the next timepoint’s sonication (tn+1). The training dataset was then formed as N×D matrix, where N is the number of total AE dataset (N = 54,040), and D is our feature dimension (D = 20). The size of the corresponding label was (N×1). All AE levels were in logarithmic values. Our training dataset had a scarce presence of broadband emission above 6 dB, which was 8% (4,299/54,040) of the total dataset. To train the model under such scarcity, the model training dataset was under-sampled55, in which we randomly selected same number of AE data from the absence of broadband emission (label = 0) that matched 80% of the number of broadband emission presence (label = 1). To train MLP model, feedforwardnet and train functions in MATLAB (Mathworks, MA) were used with 10 neurons in 1 hidden layer (a simple proof-of-concept model), epochs size of 1000, and learning rate of 0.0153, using Lavenberg-Marquardt algorithm54 to minimize mean squared error of the dataset. To test the trained model, the remaining 20% of dataset were used. Model testing was evaluated using a confusion matrix, specifically with accuracy (overall accuracy), sensitivity (i.e., recall, true positive vs. false negative), and precision (true positive vs. false positive), all of which are important metrics to evaluate machine learning models88. Feature selection was performed using SHAP values with MATLAB shapley function56, where we selected the top seven features of importance according to mean of SHAP values for feature reduction.
Attentive Multilayer Perceptron (AMP):
Inspired by attention mechanisms, which have demonstrated the ability to selectively focus on the most relevant features of input data, leading to state-of-the-art performance across multiple domains, including natural language processing89 and computer vision90, we extended the MLP concept to the context-aware modeling. The proposed model integrates cross-attention to allow patient-specific features (query) to dynamically interact with frequency components (harmonics and ultra-harmonics) from broadband acoustic emissions (key-value pairs). This enables the model to selectively prioritize informative spectral biomarkers while suppressing noise, enhancing predictive accuracy for broadband emission and ensuring a controlled physiological state. The motivation for applying attention is that traditional MLPs treat all input features equally, whereas attention mechanisms facilitate dynamic feature interactions, allowing the model to adaptively weigh critical signals in relation to the individual characteristics. By leveraging cross-attention, this attention algorithm enables individual non-MBAE features (e.g., MB Kinetics, tumor presence, etc.) to be processed in the context of real-time environmental stimuli, allowing for an adaptive decision-making process to assess MB dynamics is at risk of instability.
The dataset was formed using past AE data that utilized constant pressure sonication from total of 114 mice. We categorize the input features into two groups: (1) Patient-specific features, which include the target region in the brain (x and y coordinates referenced to the eyes), pulse number, MB kinetics, pressure, and presence or absence of tumor; and (2) Real-time treatment feedback, which consists of broadband emission extracted from AE signals. These signals were selected to be the current (tn) 2~8th (2~8f0) harmonic emission levels, 1~7th ultra-harmonic (1.5~7.5f0) emission levels. The labels for supervised machine learning classification were binary indicators of broadband emissions exceeding 6 dB above the baseline at the subsequent sonication (tn+1). The training dataset was structured as an N × [D1, D2], matrix, where N presents the total number of AE samples (N = 54,040), D1 corresponds to the patient-specific feature dimension (D1 = 6), and D2 represents the real-time frequency-driven treatment feedback measurements (D2 = [7, 7]). The corresponding labels were stored as an N × 1 vector. Since broadband emissions above 6 dB were rare, accounting for only 8% of the total dataset (4,299 out of 54,040), we maintained this ratio when splitting the data into training (80%) and test (20%) sets to reflect the real data distribution. To address this class imbalance during training, we employed weighted cross-entropy loss, assigning a weight of to broadband emissions exceeding 6 dB classes (in our case, we assign ε = 2). Additionally, we applied K= 10-fold cross-validation in training dataset to determine the optimal hyperparameters and select the best performance model. To mitigate overfitting, dropout, L2 regularization, and layer normalization were incorporated into the training process.
The AMP architecture is illustrated in Fig. S3. In this framework, individual-specific features first pass through a multilayer perceptron, encoding the information into a latent representation as the query (Q), while real-time frequency emission measurements are processed through another MLP, serving as the key (K) and value (V). The core of the architecture is the scaled dot-product mechanism, which enables interaction between these two feature sets. Q is derived from subject-specific features (fi), which encode the physiological state of the subject before sonication, fi define the individualized treatment message that the model needs to consider when deciding whether MB dynamics are controlled or at risk of instability. K is from real-time frequency feedback (fe), reflecting the acoustic response from the AE measurements during the sonication, which contains harmonic and ultra-harmonic frequency measurement. The role of the K is to provide a reference against which the patient-specific information (Q) can be compared. The dot product computation of QKT produces a score matrix where each individual information interacts with each measurement in the latent space. After normalization via SoftMax, we can get attention scores that how much focus each individual feature should have on the corresponding real-time feedback. The V matrix contains the actual measured frequency emission information, and multiplying the attention score matrix by V produces an adaptive and feedback-aware feature representation for further classification. The key advantages of AMP lie in its ability to treat subject-specific and real-time feedback features separately while enabling context-aware interactions in the latent space. The attention mechanism employs three learnable transformation matrices, allowing the model to prioritize relevant frequency components dynamically, suppress noise, thus enhance feature selection automatically. Besides, the designed architecture ensures that the patient’s state is continuously re-evaluated in real time based on AE feedback, improving the accuracy and robustness of broadband emission prediction.
Safety analysis of controllers:
The performance of the ML-assisted closed-loop (ML-CL) controller was compared with 4 other controllers during MB-FUS BBB in healthy mice at two different target levels. The first groups were treated with state-of-the-art closed-loop (CL) controller17. The second and the third group were open-loop (OL) controllers, and the exposure conditions were selected based on the average and maximum pressure used by ML-CL (PAvg and PMax). The final group was also open-loop and used a pressure value from the cavitation threshold model (PModel) that corresponds to ML-CL target level. For fair comparison, all controllers (ML-CL, CL, PAvg, PMax, and PModel) had MB kinetics tracking function (constant 60 kPa pulse, 10 ms pulse length) that initiated the controller operation. As a safety feature, ML-CL reduces pressure after ML model’s prediction of broadband emission as well as after the occurrence (reaction) of broadband emission; CL and OL controllers reduced the pressure only after the occurrence of broadband emission. To compare the performance of the controllers 32 dB or 36 dB target levels were chosen from the cavitation threshold model (pressure vs. 7th harmonic level). The first (32 dB) is expected to have a low level of broadband emission and the second (36 dB) is expected to have a high level. The key features of each controller are summarized in Table 3. For 32 dB operation, ML-CL (n=2), PAvg (n=2), PMax (n=2), and PModel (n=2), totaling of 12 targets per group. For 36 dB operation, ML-CL (n=2), CL (n=2), PAvg (n=2), PMax (n=2), totaling of 8 targets per group. Animals from NP delivery were added to the group for Ktrans analysis (6 targets per target level). For 36 dB operation in GFAP and Iba-1 staining, two targets were sonicated with ML-CL or PAvg on right hemisphere and were compared with the contralateral (left hemisphere).
Table 3 –
Different controller algorithms and the control law
| Algorithm Name | Pressure | Control Law | Safety Feature |
|---|---|---|---|
| ML-CL | Varying | Closed-loop + MLP | Reaction + Prediction |
| CL | Varying | Closed-loop (Chapter 2&3) | Reaction |
| OL (PMax) | ML-CL’s Max Pressure (PMax) | Reduce 5% pressure upon broadband emission | Reaction |
| OL (PAvg) | ML-CL’s Average Pressure (PAvg) | Reduce 5% pressure upon broadband emission | Reaction |
| OL (PModel) | Pressure from cavitation threshold model (PModel) | Reduce 5% pressure upon broadband emission | Reaction |
Experimental procedures:
All sonications were performed with the FUS transducer operated at 0.5 MHz, with 10 ms pulse length and 1 Hz pulse repetition frequency, for 130 seconds under concurrent bolus intravenous (i.v.) administration of clinical grade lipid shell microbubbles (100 μL/kg, Definity, Lantheus Medical Imaging). For rat experiments, lab-made Definity-like MBs were used due to limited product supply. MB type, dose, and administration protocols were consistent with those used to collect the machine learning training datasets. During the sonications, we recorded/controlled the AE using the single element PCD. DCE-MRI was taken right after the sonication sessions. Mouse sonications: For 32 dB target level, six target regions in the brain (three in each hemisphere) were sonicated. For 36 dB target level, four target regions in the brain (two in each hemisphere) were sonicated. For NP delivery, four target regions were sonicated (32 dB on left and 36 dB on right). For brain tumor liquid biopsy, we performed five sonications (XY directions, separated by 1 mm) to cover the entire tumor and its periphery, and one healthy contralateral target was sonicated for targeting confirmation. Rat sonications: For NP delivery in tumors and brain tumor liquid biopsy, seven target regions were sonicated (XY directions separated by 1mm) to cover the entire tumor and its periphery.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI):
To access the vessel permeability in the brain, we measured the volume transfer constant, Ktrans, by performing DCE-MRI (Pharmascan 7T, Bruker, IR, echo time, 2.5 ms; rep time, 1019.6 ms; flip angle, 30; FOV, 40 × 40 mm2) after the last sonication. Prior to injecting the contrast agents, we acquired background image in 6 different flip angles (2, 5, 10, 15, 20, and 30 degrees) to quantify T1 relaxation map, which is used for Ktrans quantification. Consequently, we started collecting DCE-MRI with concurrent bolus administration of 8 μl gadolinium contrast agent (0.4 mL/kg, Prohance). The collected DCE-MRIs datasets were analyzed and Ktrans values were calculated in Horos, using DCE tool plugin (Kyung Sung, Los Angeles, California). The arterial input function (AIF) was obtained based on Fritz-Hansen et al. method, as provided in the plugin91.
Brain tissue processing:
Following MB-FUS treatments/sonications, the mice and rats were euthanized 2- or 6-hours post-treatment and transcardially perfused with 20 mL and 160mL of saline, respectively. For brain staining, perfusion continued with 4% paraformaldehyde (PFA) before harvesting the brains. Then, the brains were fixed with 4% PFA overnight at 4°C, followed by immersion in a 30% sucrose solution at 4°C until they sank to the bottom of the container. The brains were then embedded in O.C.T. compound and rapidly frozen to −80°C. Subsequently, 20 μm sections were cut using a cryostat (Leica 3050 S Cryostat) for further analysis. For NP delivery, brains were harvested after transcardial perfusion with saline and analyzed immediately (no exposure to PFA).
Immunofluorescence / Immunohistochemistry staining and microscope imaging:
To assess the safety and the biological effects induced by MB-FUS, immunofluorescence staining was performed on brain tissue slides. Tissues were first fixed in 4% paraformaldehyde at room temperature for 10 minutes. For sections requiring staining of intracellular markers (e.g., GFAP and Iba-1, which are markers for astrocyte and microglial activation for safety assessment), they were subsequently permeabilized with 0.1% Triton X-100 in PBS for 5 minutes. After washing with PBS, the sections were blocked for 1 hour at room temperature in a solution containing 1% Bovine Serum Albumin and 5% goat serum in PBS.
The sections were then incubated with the primary antibody of interest, diluted in 1% Bovine Serum Albumin (1:100), for 12 hours at 4°C. Following primary antibody incubation, the sections were incubated with the secondary antibody, diluted in 1% Bovine Serum Albumin (1:250), for 1 hour at room temperature. To stain the cell nucleus, samples were incubated with DAPI diluted in PBS (1:1000) for 10 minutes after washing. Finally, the sections were rinsed with PBS to remove excess antibody, mounted with mounting medium, and covered with coverslips. Samples were cured with mounting medium for 24 hours in the dark at room temperature before imaging. The sections were imaged with a 20x objective using a fluorescence microscope (Eclipse Ti2, Nikon). The quantification of the fluorescence images was performed using ImageJ.
Hematoxylin-eosin staining was performed to examine tissue damage and safety. Twenty-micrometer thick frozen sections (Leica 3050 S Cryostat) were dehydrated beforehand and stained using a Leica Autostainer (ST5010). The sections were imaged with a 20x objective using a brightfield microscope (Eclipse Ti2, Nikon).
Statistical analysis:
Results are expressed as means ± standard deviation (or SEM if stated under caption). Statistical analyses were performed using MATLAB and GraphPad Prism 7.0. For statistical analysis of two independent groups, an unpaired Student’s t-test was applied. For statistical analysis of self-comparison groups, a paired Student’s t-test was applied. For grouped analyses, we performed a One-way ANOVA, multiple comparison with Bonferroni’s correction. p < 0.05 was considered statistically significant (*p<0.5, **p<0.01, ***p<0.001, and ****p<0.0001, ns = not significant). For variance tests, f-test were used, and Levene’s test was used for skewed distributions. Data distribution was assumed to be normal (unless described in the manuscript for skewed distributions), but this was not formally tested in all data. Tumor-bearing animals were inoculated with tumors and then randomized prior to allocation to experimental groups. For the remaining studies, randomization was not relevant, as these experiments were conducted on uniform biological materials, such as commercially sourced cell lines. The investigators were not blinded to group allocation during experiments and outcome analysis. Blinding was not feasible for both the in vitro and in vivo studies, as these experiments were conducted by individual investigators who were aware of the experimental groups. Additionally, blinding was not considered relevant, as the data analysis was performed quantitatively (e.g., bioanalyzer quantification, PCR, and digital-PCR) and did not involve subjective, qualitative assessments. Animals were randomly assigned to experimental groups, but the experiments were not randomized, and the investigators were not blinded to group allocation or outcome assessment. Animal sample exclusion was minimized and only applied either when critical procedures failed or data fell below or above the negative or positive controls, respectively (see animal exclusion criteria section).
Sample Exclusion Criteria:
One mouse was excluded from the 36dB LB group due to mistargeting of the tumor, confirmed by contrast-enhanced MR imaging and observed in abnormal fluctuation of biomarker levels in the blood. Protein samples from 1 ML-CL rat were excluded due to luminescence signal below the negative control, included in the same Bioanalyzer run. ctDNA samples from 1 Pavg rat were excluded as quantification surpassed the positive control included in the same dPCR run. ctDNA samples from 1 ML-CL rat were excluded due to human error during the purification step. Overall, additional animals were placed in each of these groups to maintain n≥5.
Nanoparticle preparation:
To formulate PEGylated polystyrene nanoparticles, 20, 40, and 100 nm carboxylate-modified FluoSpheres™ (PS-COOH, Ex/Em: 580/605 nm, Invitrogen) were covalently modified with amine-terminated 5 kDa MW polyethylene glycol (methoxy-PEG5k-amine, Creative PEGWorks) by EDC carbodiimide chemistry, following a protocol we previously described92–94. Briefly, PS-COOH nanoparticles (2 mg) were mixed with methoxy-PEG5k-amine (4–5x equivalent to total COOH groups on surface of PS-COOH particles) in 100 mM borate buffer (pH 8.2), followed by addition of excess sulfo-NHS (~24x), and EDC (~8x). Particle suspensions were placed on a rotary incubator and the reaction was allowed to proceed for 4 h at 25°C. After the reaction, particles were purified by ultracentrifugation (Amicon Ultra-15 mL 100 kDa MW cut-off, Millipore Sigma) with sterile PBS (pH 7.4) as the buffer (3 washes total). Finally, the purified nanoparticles were resuspended in sterile PBS (1 ml) and stored at 4 °C for subsequent characterizations and use in in vivo studies.
The physicochemical characteristics of PEGylated polystyrene nanoparticles were measured in 15x diluted PBS (~10 mM NaCl, pH 7.4) at 25°C. Hydrodynamic diameter and ζ-potential (surface charge) were determined by dynamic light scattering and laser Doppler anemometry, respectively, using a Zetasizer NanoZS (Malvern Instruments, Southborough, MA). Particle size measurement was performed at 25°C at a scattering angle of 173° and is reported as the number-average mean. The ζ -potential values were calculated using the Smoluchowski equation and is reported as the mean ζ -potential. Detailed characterization shown in Table 4.
Nanoparticle delivery and quantification:
The sonications were performed as described previously, but the order of first sonicated side was alternated in between mice of the same group to account for MB accumulation. After the sonications were completed, each mouse received a 100μL intravenous bolus-injection of the designated NP size. PEGylated NPs were prepared for these injections at a concentration of 5 mg/kg. Considering an average body weight of 20g for mice and 160g for rats, each mouse received 0.1mg diluted in 100 μL and each rat received 0.8mg diluted in 800μL. The 37 nm, 46 nm, and 120 nm-NPs had stock concentrations of 1.3 mg/mL, 1.8 mg/mL, and 4.0 mg/mL. For mice, considering a 10% additional volume preparation, 84.61 μL of 37 nm-NPs were mixed with 25.39 μL of saline, 61.11 μL of 46 nm-NPs were mixed with 48.89 μL of saline, and 27.5 μL of 120 nm-NPs were mixed with 82.5 μL of saline, making a total of 110 μL of prepared NPs per injection. For rats, considering a 10% additional volume preparation, 676.9μL of 37 nm-NPs were mixed with 203.1μL of saline, 488.9μL of 46 nm-NPs were mixed with 391.1μL of saline, and 220μL of 120 nm-NPs were mixed with 660μL of saline, making a total of 880μL of prepared NPs per injection.Animals were euthanized 2h-post NP injection and transcardially perfused with 20mL (mice) or 160mL (rats) of saline.□
To account for variations in size-dependent NP fluorescence signal, in vitro NP signal was assessed a priori for each size using the concentrations detailed above. Triplicate samples of 55μL of PBS and each NP size, same concentration from in vivo experiments, were individually placed into a black-walled, clear-bottom 96-well. Then, the well plate was placed in the Perkin Elmer IVIS Spectrum CT (Waltham, MA, USA) for fluorescent imaging of the brain. The machine was programmed using the Perkin Elmer Living Image 4.7.4 to capture fluorescent images with excitation at 570 nm and emission at 620 nm, exposure time of 0.5 second, lamp at low level, medium binning, C field of view, subject height at 1.00 cm, chamber temperature at 37 °C, and the lamp temperature at −90 °C. The machine was initially programmed to match the fluorescent particle’s original excitation of 580 nm and emission of 605 nm, but it automatically defaulted to the values above due to the range of filters installed. Measurements of total radiant efficiency were taken by placing the uniform region of interest (ROI) at the center of each well and covered the entire surface area. The color scale range was set from 2×109 to 5×1010 (p/s)/(μW/cm2). The in vitro samples were used to normalize the fluorescent signal from 0 to 1 (highest measurement). Once normalized, the mean ratio of each size group was calculated and used to correct the recorded in vivo levels, as described below.
The harvested brains were immediately placed in the Perkin Elmer IVIS Spectrum CT (Waltham, MA, USA) for fluorescent imaging. The machine was programmed as before with exposure time of 10.0 seconds. The fluorescent image overlapped with the photograph of the brain. Measurements of total radiant efficiency were taken by placing the uniform ROI at the center of each sonication target. The color scale range was set from 9×107 to 2.5×108 (p/s)/(μW/cm2). To compare the delivery of NPs, the in vivo data was divided by the mean of the normalized in vitro data of each NP size group.
Cell lines and cell culturing:
GL261 glioma (Caliper Life Sciences, Hopkinton, MA, USA) and F98npEGFRviii cells (ATCC, Manassas, Virginia, USA) were separately cultured in Dulbecco’s modified Eagle’s medium supplemented with 10% fetal bovine serum (FBS) and 1% penicillin-streptomycin at 37°C and 5% CO2.
Gaussia Luciferase transduction of GL-261 and F98-EGFRviii cell lines:
GL-261 and F98-EGFRviii cell lines were transduced with Gaussia Luciferase (GLuc) using polybrene and the lentivirus cytomegalovirus humanized-GLuc (LV-CMV-GLuc-Puro, SignaGen Laboratories, Frederick, MD, USA) with the multiplicity of infection (MOI) equal to 2. Transduced cells were selected with overnight puromycin exposure at 10mg/mL.
Tumor inoculation and growth in mice:
GL-261-GLuc (mice) and F98-GLuc (rat) cells (105 cells) were stereotactically implanted into the brain at 1-mm anterior, 1- mm to the right of the bregma, and 2-mm deep to skull bottom of 10-week-old female C57BL/6J mice (The Jackson Laboratory), or SRG (Sprague Dawley-Rag2 Il2rg/HblCrl)/Fisher CDF (F344/DuCrl) rats (Charles River). All tumors were allowed to grow up to 2.5 mm and then mice were evenly distributed among groups according to tumor volume that was quantified using the ellipsoid volume equation.
Liquid Biopsy experiments:
To assess the diagnostic potential of the proposed ML-CL controller, we employed it on GL-261-GLuc tumor-bearing mice (n = 6) and F98-GLuc tumor-bearing rats (n=7). Each animal was treated with 5 (mouse) or 7 (rat) sonication targets using ML-assisted controller to cover the tumor region at target levels established to be safe in healthy brains. To compare the role of FUS in brain tumor liquid biopsy, we split animals from the same cohort into a control group (n = 4 for mouse and 5 for rats), where no FUS was employed. These animals received the same MB injections with time intervals in between to represent each target sonication duration.
Blood collection and Serum Isolation:
For mouse, blood samples (225μL/each) were collected retro-orbitally 5 minutes before and 15 minutes after sonication of the treatment midpoint (for both FUS and control groups), and 2-hours-post-treatment (terminal – for FUS group) using EDTA-coated capillary tubes attached to a non-coated 1.5mL microcentrifuge tube. For rats, blood samples (1.2mL/each) were collected from the subclavian vein 5 minutes before and after sonication the treatment midpoint (for both FUS and control groups), using a 23G-needle attached to a luer slip syringe, and transferred to a non-coated 1.5mL microcentrifuge tube. All samples were allowed to coagulate in ice for 10 minutes prior to 1,000g centrifugation for 20 minutes. Serum was allocated for protein quantification (20μL – all animals) and ctDNA (80μL for mice and 500 μL for rats) purification/quantification.
Protein Quantification:
Serum (20μL) of each sample was placed in a single well of a black-walled, clear-bottom 96-well plate. Coelenterazine solution from the Pierce Gaussia Luciferase Glow assay kit (ThermoFisher, Waltham, MA, USA) was added to each well immediately prior to measurements using Synergy HT Microplate reader (Biotek Instruments, Santa Clara, CA, USA). Luminescence measurements were taken for 10 minutes at 30s intervals, with no lid, 1.0 mm height, 100ms delay, 135dB gain, and hole emission. Measurements for the first 5 minutes were considered and integrated, remaining measurements were disregarded due to signal decay after this timepoint.
Circulating-tumor DNA (ctDNA) Purification and dPCR Quantification:
Serum samples were placed in individual sterile 1.5mL microcentrifuge tubes, purified using the Plasma/Serum cell-free DNA Purification kit (Norgen Biotek, Ontario, Canada), and eluted to a final volume of 30μL. All samples were frozen overnight at −20°C.
Rat samples were pre-amplified using the Q5 Reaction kit (New England Biolabs, Ipswich, MA, USA) and forward and reverse primers, eluted in 10μM, with sequences 5’-AGAGATGGAAGCCAATGCCC-3’ and 5’-GTGCAGTCCACACACAGATC-3’, respectively. Each reaction included 10μL of the Q5 Reaction Buffer and 10μL of the Q5 High GC Enhancer (B9027S), 0.5μL of the Q5 High-Fidelity DNA Polymerase, 1μL of the Q5 dNTP Solution Mix, 0.5μL of each of the forward and reverse primers, 22.5μL of PCR-grade water, and 5μL of the template ctDNA sample. Reaction samples were placed in 0.5mL Eppendorf PCR tubes and run using Applied Biosystems’ Pro Flex PCR Thermocycler, which was programmed to process 1 cyle at 98°C for 30 seconds, and 10x cycles of 98°C for 10 seconds plus 68°C for 20 seconds plus 72°C for 15 seconds, and 1 cycle of 72°C for 2 minutes.
Custom fluorescent probe and sequence primers were synthesized for GLuc gene detection (Integrated DNA Technologies, Coralville, IA, USA). The probe, eluted at 100μM, has sequence of 5’-/56-FAM/CTGTCCCA/3IABIFQ-3’, and the forward and reverse primer sequences for GLuc gene, both eluted at 10μM, are 5’-ACCAGGGGCTGTCTGATCT-3’ and 5’–GGGATGAACTTCTTCATCTTGG–3’, respectively. Mouse and pre-amplified rat samples were processed for amplification and quantification. Each DNA sample was prepared by mixing 4μL of template ctDNA with 1.6μL of the probe, 0.32μL of forward and reverse primers, 10μL of QIAcuity dPCR Probe Master Mix (QiAgen, Hilden, Germany), and 23.76μL of PCR-grade water. All dPCR runs included in vitro positive control and negative control (PCR-grade water in place of DNA) samples. Samples were added to QIAcuity Nanoplate 26k 8-well/24-well plates and processed using QiAgen QIAcuity One digital-PCR (QiAgen, Hilden, Germany). dPCR was programmed to process FAM signal and included 1 cycle at 95°C for 2 minutes, and 40 cycles composed of 95°C for 15 seconds and 60°C for 30 seconds.
Supplementary Material
Acknowledgments:
We thank Dr. Johannes Leisen at Georgia Tech’s Magnetic Resonance Imaging core (MRI) facility for his outstanding technical support during FUS studies. We thank Dr. Andrew Kristof from the Immunological and Cellular Engineering Lab at Georgia Tech for his help with Gaussia Luciferase lentivirus transduction of F98-EGFRviii cell line.
Funding:
This study was supported by the NIH Grant R37CA239039 (NCI) and the Focused Ultrasound Foundation (AWD 004091).
Funding Statement
This study was supported by the NIH Grant R37CA239039 (NCI) and the Focused Ultrasound Foundation (AWD 004091).
Footnotes
Competing interests: The authors declare no competing interests. CB is a consultant for Haystack Oncology, Bionaut Labs, Privo Technology. CB is a co-founder of OrisDx and Belay Diagnostics
Data and materials availability:
All data needed to evaluate the conclusions in the paper are present in the paper and/or the Supplementary Materials. Any additional requests for information can be directed to, and will be fulfilled by, the corresponding authors. Source data are provided with this paper.
References
- 1.Vanlandewijck M. et al. A molecular atlas of cell types and zonation in the brain vasculature. Nature 554, 475–480 (2018). [DOI] [PubMed] [Google Scholar]
- 2.Wälchli T. et al. Shaping the brain vasculature in development and disease in the single-cell era. Nat Rev Neurosci 1–28 (2023) doi: 10.1038/s41583-023-00684-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Iliff J. J. et al. A Paravascular Pathway Facilitates CSF Flow Through the Brain Parenchyma and the Clearance of Interstitial Solutes, Including Amyloid β. Science Translational Medicine 4, 147ra111–147ra111 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Iadecola C. The Neurovascular Unit Coming of Age: A Journey through Neurovascular Coupling in Health and Disease. Neuron 96, 17–42 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Wu D. et al. The blood–brain barrier: Structure, regulation and drug delivery. Sig Transduct Target Ther 8, 1–27 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Arvanitis C. D., Ferraro G. B. & Jain R. K. The blood–brain barrier and blood–tumour barrier in brain tumours and metastases. Nat Rev Cancer 20, 26–41 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Abbott N. J. Blood–brain barrier structure and function and the challenges for CNS drug delivery. J Inherit Metab Dis 36, 437–449 (2013). [DOI] [PubMed] [Google Scholar]
- 8.Kreuter J. Drug delivery to the central nervous system by polymeric nanoparticles: What do we know? Advanced Drug Delivery Reviews 71, 2–14 (2014). [DOI] [PubMed] [Google Scholar]
- 9.Tapeinos C., Battaglini M. & Ciofani G. Advances in the design of solid lipid nanoparticles and nanostructured lipid carriers for targeting brain diseases. Journal of Controlled Release 264, 306–332 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Connolly I. D., Li Y., Gephart M. H. & Nagpal S. The “Liquid Biopsy”: the Role of Circulating DNA and RNA in Central Nervous System Tumors. Curr Neurol Neurosci Rep 16, 25 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Bettegowda C. et al. Detection of Circulating Tumor DNA in Early- and Late-Stage Human Malignancies. Science Translational Medicine 6, 224ra24–224ra24 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Sarkaria J. N. et al. Is the blood-brain barrier really disrupted in all glioblastomas? A critical assessment of existing clinical data. Neuro-oncology 20, 184–191 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Hynynen K., McDannold N., Vykhodtseva N. & Jolesz F. A. Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits1. Radiology 220, 640–646 (2001). [DOI] [PubMed] [Google Scholar]
- 14.Aryal M., Arvanitis C. D., Alexander P. M. & McDannold N. Ultrasound-mediated blood–brain barrier disruption for targeted drug delivery in the central nervous system. Advanced Drug Delivery Reviews 72, 94–109 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Arvanitis C. D. et al. Mechanisms of enhanced drug delivery in brain metastases with focused ultrasound-induced blood–tumor barrier disruption. Proceedings of the National Academy of Sciences 115, E8717–E8726 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Schoen S. et al. Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Advanced Drug Delivery Reviews 180, 114043 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Lee H. et al. Spatially targeted brain cancer immunotherapy with closed-loop controlled focused ultrasound and immune checkpoint blockade. Science Advances 8, eadd2288 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Meng Y., Hynynen K. & Lipsman N. Applications of focused ultrasound in the brain: from thermoablation to drug delivery. Nature Reviews Neurology 17, 7–22 (2021). [DOI] [PubMed] [Google Scholar]
- 19.Leinenga G., Langton C., Nisbet R. & Götz J. Ultrasound treatment of neurological diseases — current and emerging applications. Nature Reviews Neurology (2016) doi: 10.1038/nrneurol.2016.13. [DOI] [PubMed] [Google Scholar]
- 20.Wilhelm S. et al. Analysis of nanoparticle delivery to tumours. Nat Rev Mater 1, 1–12 (2016). [Google Scholar]
- 21.Nouraein S. et al. Acoustically targeted noninvasive gene therapy in large brain volumes. Gene Ther 31, 85–94 (2024). [DOI] [PubMed] [Google Scholar]
- 22.Ohta S. et al. Investigating the optimum size of nanoparticles for their delivery into the brain assisted by focused ultrasound-induced blood–brain barrier opening. Sci Rep 10, 18220 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Mead B. P. et al. Targeted gene transfer to the brain via the delivery of brain-penetrating DNA nanoparticles with focused ultrasound. Journal of Controlled Release 223, 109–117 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Lin C.-Y. et al. Non-invasive, neuron-specific gene therapy by focused ultrasound-induced blood-brain barrier opening in Parkinson’s disease mouse model. Journal of Controlled Release 235, 72–81 (2016). [DOI] [PubMed] [Google Scholar]
- 25.Åslund A. K. O. et al. Nanoparticle delivery to the brain — By focused ultrasound and self-assembled nanoparticle-stabilized microbubbles. Journal of Controlled Release 220, 287–294 (2015). [DOI] [PubMed] [Google Scholar]
- 26.Treat L. H., McDannold N., Zhang Y., Vykhodtseva N. & Hynynen K. Improved Anti-Tumor Effect of Liposomal Doxorubicin After Targeted Blood-Brain Barrier Disruption by MRI-Guided Focused Ultrasound in Rat Glioma. Ultrasound in Medicine & Biology 38, 1716–1725 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Curley C. T. et al. Augmentation of brain tumor interstitial flow via focused ultrasound promotes brain-penetrating nanoparticle dispersion and transfection. Science Advances 6, eaay1344 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Rincon-Torroella J., Khela H., Bettegowda A. & Bettegowda C. Biomarkers and focused ultrasound: the future of liquid biopsy for brain tumor patients. J Neurooncol 156, 33–48 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Meng Y. et al. MR-guided focused ultrasound liquid biopsy enriches circulating biomarkers in patients with brain tumors. Neuro-Oncology 23, 1789–1797 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Zhu L. et al. Focused Ultrasound-enabled Brain Tumor Liquid Biopsy. Sci Rep 8, 6553 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Pacia C. P. et al. Feasibility and safety of focused ultrasound-enabled liquid biopsy in the brain of a porcine model. Sci Rep 10, 7449 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Pacia C. P. et al. Sonobiopsy for minimally invasive, spatiotemporally-controlled, and sensitive detection of glioblastoma-derived circulating tumor DNA. Theranostics 12, 362–378 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Yuan J. et al. First-in-human prospective trial of sonobiopsy in high-grade glioma patients using neuronavigation-guided focused ultrasound. npj Precis. Onc. 7, 1–11 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Chevillet J. R. et al. Release of Cell-free MicroRNA Tumor Biomarkers into the Blood Circulation with Pulsed Focused Ultrasound: A Noninvasive, Anatomically Localized, Molecular Liquid Biopsy. Radiology 283, 158–167 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Zhu L., Nazeri A., Pacia C. P., Yue Y. & Chen H. Focused ultrasound for safe and effective release of brain tumor biomarkers into the peripheral circulation. PLoS ONE 15, e0234182 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.McDannold N., Arvanitis C. D., Vykhodtseva N. & Livingstone M. S. Temporary Disruption of the Blood–Brain Barrier by Use of Ultrasound and Microbubbles: Safety and Efficacy Evaluation in Rhesus Macaques. Cancer Res 72, 3652–3663 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Anastasiadis P. et al. Localized blood–brain barrier opening in infiltrating gliomas with MRI-guided acoustic emissions–controlled focused ultrasound. PNAS 118, (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Mondou P. et al. State of the art on microbubble cavitation monitoring and feedback control for blood-brain-barrier opening using focused ultrasound. Phys. Med. Biol. 68, 18TR03 (2023). [DOI] [PubMed] [Google Scholar]
- 39.Sun T. et al. Closed-loop control of targeted ultrasound drug delivery across the blood–brain/tumor barriers in a rat glioma model. Proc Natl Acad Sci USA 114, E10281–E10290 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.O’Reilly M. A. & Hynynen K. Blood-Brain Barrier: Real-time Feedback-controlled Focused Ultrasound Disruption by Using an Acoustic Emissions–based Controller. Radiology 263, 96–106 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Çavuşoğlu M. et al. Closed-loop cavitation control for focused ultrasound-mediated blood–brain barrier opening by long-circulating microbubbles. Phys. Med. Biol. 64, 045012 (2019). [DOI] [PubMed] [Google Scholar]
- 42.McMahon D., Lassus A., Gaud E., Jeannot V. & Hynynen K. Microbubble formulation influences inflammatory response to focused ultrasound exposure in the brain. Sci Rep 10, 21534 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.McDannold N. et al. Acoustic feedback enables safe and reliable carboplatin delivery across the blood-brain barrier with a clinical focused ultrasound system and improves survival in a rat glioma model. Theranostics 9, 6284–6299 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Bing C. et al. Characterization of different bubble formulations for blood-brain barrier opening using a focused ultrasound system with acoustic feedback control. Sci Rep 8, 7986 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Chien C.-Y., Xu L., Pacia C. P., Yue Y. & Chen H. Blood–brain barrier opening in a large animal model using closed-loop microbubble cavitation-based feedback control of focused ultrasound sonication. Sci Rep 12, 16147 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Ji R. et al. Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening. Journal of Controlled Release 337, 458–471 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Aryal M., Vykhodtseva N., Zhang Y.-Z., Park J. & McDannold N. Multiple treatments with liposomal doxorubicin and ultrasound-induced disruption of blood–tumor and blood–brain barriers improve outcomes in a rat glioma model. Journal of Controlled Release 169, 103–111 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Tsai H.-C. et al. Safety evaluation of frequent application of microbubble-enhanced focused ultrasound blood-brain-barrier opening. Sci Rep 8, 17720 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Leinenga G. & Götz J. Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model. Sci Transl Med 7, 278ra33–278ra33 (2015). [DOI] [PubMed] [Google Scholar]
- 50.Pandit R., Leinenga G. & Götz J. Repeated ultrasound treatment of tau transgenic mice clears neuronal tau by autophagy and improves behavioral functions. Theranostics 9, 3754–3767 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Huang Y., Bathiany S., Ashwin P. & Boers N. Deep learning for predicting rate-induced tipping. Nat Mach Intell 6, 1556–1565 (2024). [Google Scholar]
- 52.Scheffer M. et al. Early-warning signals for critical transitions. Nature 461, 53–59 (2009). [DOI] [PubMed] [Google Scholar]
- 53.Rumelhart D. E., Hinton G. E. & Williams R. J. Learning representations by back-propagating errors. Nature 323, 533–536 (1986). [Google Scholar]
- 54.Hagan M. T. & Menhaj M. B. Training feedforward networks with the Marquardt algorithm. IEEE Transactions on Neural Networks 5, 989–993 (1994). [DOI] [PubMed] [Google Scholar]
- 55.He H. & Garcia E. A. Learning from Imbalanced Data. IEEE Transactions on Knowledge and Data Engineering 21, 1263–1284 (2009). [Google Scholar]
- 56.Lundberg S. M. & Lee S.-I. A unified approach to interpreting model predictions. in Proceedings of the 31st International Conference on Neural Information Processing Systems 4768–4777 (Curran Associates Inc., Red Hook, NY, USA, 2017). [Google Scholar]
- 57.Emmer M., van Wamel A., Goertz D. E. & de Jong N. The Onset of Microbubble Vibration. Ultrasound in Medicine & Biology 33, 941–949 (2007). [DOI] [PubMed] [Google Scholar]
- 58.Leighton T. G. 4 - The Forced Bubble. in The Acoustic Bubble (ed. Leighton T. G.) 287–438 (Academic Press, 1994). doi: 10.1016/B978-0-12-441920-9.50009-2. [DOI] [Google Scholar]
- 59.Stride E. & Coussios C. Nucleation, mapping and control of cavitation for drug delivery. Nat Rev Phys 1, 495–509 (2019). [Google Scholar]
- 60.Song K.-H., Harvey B. K. & Borden M. A. State-of-the-art of microbubble-assisted blood-brain barrier disruption. Theranostics 8, 4393–4408 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.McMahon D. & Hynynen K. Acute Inflammatory Response Following Increased Blood-Brain Barrier Permeability Induced by Focused Ultrasound is Dependent on Microbubble Dose. Theranostics 7, 3989–4000 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Kovacs Z. I., Burks S. R. & Frank J. A. Focused ultrasound with microbubbles induces sterile inflammatory response proportional to the blood brain barrier opening: Attention to experimental conditions. Theranostics 8, 2245–2248 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.McMahon D. & Hynynen K. Reply to Kovacs et al.: Concerning acute inflammatory response following focused ultrasound and microbubbles in the brain. Theranostics 8, 2249 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Baron J.-C., Yamauchi H., Fujioka M. & Endres M. Selective neuronal loss in ischemic stroke and cerebrovascular disease. J Cereb Blood Flow Metab 34, 2–18 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Rigollet S. et al. FUS-mediated BBB opening leads to transient perfusion decrease and inflammation without acute or chronic brain lesion. Theranostics 14, 4147–4160 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Balzano T. et al. Temporal dynamics of neurovascular unit changes following blood-brain barrier opening in the putamen of non-human primates. Journal of Controlled Release 377, 116–126 (2025). [DOI] [PubMed] [Google Scholar]
- 67.Nance E. A. et al. A Dense Poly(Ethylene Glycol) Coating Improves Penetration of Large Polymeric Nanoparticles Within Brain Tissue. Science Translational Medicine 4, 149ra119–149ra119 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Guo Y. et al. Single-cell analysis reveals effective siRNA delivery in brain tumors with microbubble-enhanced ultrasound and cationic nanoparticles. Science Advances 7, eabf7390 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Tannous B. A. Gaussia luciferase reporter assay for monitoring of biological processes in culture and in vivo. Nat Protoc 4, 582–591 (2009). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Kimura T., Hiraoka K., Kasahara N. & Logg C. R. Optimization of enzyme-substrate pairing for bioluminescence imaging of gene transfer using Renilla and Gaussia luciferases. J. Gene Med. 12, 528–537 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Ricroch A. & Brown S. C. DNA base composition of Allium genomes with different chromosome numbers. Gene 205, 255–260 (1997). [DOI] [PubMed] [Google Scholar]
- 72.Nguyen V.-C. et al. Fragment length profiles of cancer mutations enhance detection of circulating tumor DNA in patients with early-stage hepatocellular carcinoma. BMC Cancer 23, 233 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Odaka C. & Mizuochi T. Macrophages are involved in DNA degradation of apoptotic cells in murine thymus after administration of hydrocortisone. Cell Death and Differentiation. [DOI] [PubMed] [Google Scholar]
- 74.Liu Q. et al. Biodistribution and residence time of adenovector serotype 5 in normal and immunodeficient mice and rats detected with bioluminescent imaging. Sci Rep 7, 3597 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75.Meng Y. et al. Technical Principles and Clinical Workflow of Transcranial MR-Guided Focused Ultrasound. Stereotactic and Functional Neurosurgery 99, 329–342 (2020). [DOI] [PubMed] [Google Scholar]
- 76.Durham P. G. et al. Current clinical investigations of focused ultrasound blood-brain barrier disruption: A review. Neurotherapeutics 21, e00352 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Coluccia D. et al. Enhancing glioblastoma treatment using cisplatin-gold-nanoparticle conjugates and targeted delivery with magnetic resonance-guided focused ultrasound. Nanomedicine: Nanotechnology, Biology and Medicine 14, 1137–1148 (2018). [DOI] [PubMed] [Google Scholar]
- 78.Guo Y. et al. Ultrasound frequency-controlled microbubble dynamics in brain vessels regulate the enrichment of inflammatory pathways in the blood-brain barrier. Nat Commun 15, 8021 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Dunham C. & Frank J. Age influences therapeutic ultrasound effects: From increased inflammation in young to decreased inflammaging in adults. Physiology 39, 268 (2024). [Google Scholar]
- 80.Morse S. V., Mishra A., Chan T. G., de Rosales R. T. M. & Choi J. J. Liposome delivery to the brain with rapid short-pulses of focused ultrasound and microbubbles. Journal of Controlled Release 341, 605–615 (2022). [DOI] [PubMed] [Google Scholar]
- 81.Dauba A. et al. Recent Advances on Ultrasound Contrast Agents for Blood-Brain Barrier Opening with Focused Ultrasound. Pharmaceutics 12, 1125 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Guo Y. et al. Single-cell analysis reveals effective siRNA delivery in brain tumors with microbubble-enhanced ultrasound and cationic nanoparticles. Sci. Adv. 7, eabf7390 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Kim J. E., Kalimuthu S. & Ahn B.-C. In Vivo Cell Tracking with Bioluminescence Imaging. Nucl Med Mol Imaging 49, 3–10 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Eun H.-M. Enzymology Primer for Recombinant DNA Technology. (Elsevier, 1996). [Google Scholar]
- 85.Davidson M. et al. Detecting and Tracking Circulating Tumour DNA Copy Number Profiles during First Line Chemotherapy in Oesophagogastric Adenocarcinoma. Cancers 11, 736 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86.Padovan-Merhar O. et al. Single Mammalian Cells Compensate for Differences in Cellular Volume and DNA Copy Number through Independent Global Transcriptional Mechanisms. Molecular Cell 58, 339–352 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87.Martin-Alonso C. et al. Priming agents transiently reduce the clearance of cell-free DNA to improve liquid biopsies. Science 383, eadf2341 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Bishop C. M. Pattern Recognition and Machine Learning. (Springer, 2006). [Google Scholar]
- 89.Vaswani A. et al. Attention is All you Need. in Advances in Neural Information Processing Systems vol. 30 (Curran Associates, Inc., 2017). [Google Scholar]
- 90.Dosovitskiy A. et al. An Image is Worth 16×16 Words: Transformers for Image Recognition at Scale. Preprint at 10.48550/arXiv.2010.11929 (2021). [DOI] [Google Scholar]
- 91.Wu S.-Y., Chen C. C., Tung Y.-S., Olumolade O. O. & Konofagou E. E. Effects of the microbubble shell physicochemical properties on ultrasound-mediated drug delivery to the brain. Journal of Controlled Release 212, 30–40 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92.Schneider C. S. et al. Minimizing the Non-specific Binding of Nanoparticles to the Brain Enables Active Targeting of Fn14-positive Glioblastoma Cells. Biomaterials 42, 42–51 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Kim A. J. et al. Use of Single-Site Functionalized PEG-Dendrons to Prepare Gene Vectors that Penetrate Human Mucus Barriers. Angew Chem Int Ed Engl 52, 3985–3988 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94.Dancy J. G. et al. Non-specific binding and steric hindrance thresholds for penetration of particulate drug carriers within tumor tissue. J Control Release 238, 139–148 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data needed to evaluate the conclusions in the paper are present in the paper and/or the Supplementary Materials. Any additional requests for information can be directed to, and will be fulfilled by, the corresponding authors. Source data are provided with this paper.







