HIGH IMPACT BUNDLE: Electroencephalogram (EEG) Correlates of Infant Spinal Anesthesia

Chang Amber Liu 1, Johanna M Lee 1, Ashlee Holman 2, Grant Heydinger 3, Emmett E Whitaker 4, Jerry Y Chao 5
PMCID: PMC12353545  NIHMSID: NIHMS2078128  PMID: 39808708

Spinal anesthesia is a powerful alternative to general anesthesia in infants undergoing infraumbilical procedures, with advantageous physiological properties unique to the first year of life1. Clinicians have long observed and leveraged the beneficial attributes of infant spinal anesthesia to confer greater cardiorespiratory stability compared to general anesthesia. Successful administration of spinal anesthesia avoids intraoperative hypotension2, the need for airway instrumentation, and reduces the incidence of early postoperative apnea3. Infant spinal anesthesia has also been shown to have operational benefits including shorter operating room and recovery unit times4 as well as lower pain scores in some institutions5. A common observation in pediatric patients after administration of plain intrathecal bupivacaine is a clinically striking decreased state of arousal and reduced level of consciousness resembling “sleep” without the administration of any sedative-hypnotic agents1. The mechanism by which bupivacaine causes motor and sensory blockade is known to be via antagonism of sodium channels at the level of the spinal cord. However, less is known about what accounts for the effect of spinal anesthesia on wakefulness, and whether the associated sedation classically observed in very young children reflects an anesthetized state, a sleep state, or some combination of both.

Prior research in the adult population has demonstrated that epidural and spinal anesthesia are associated with increased levels of sedation6,7 and decreased anesthetic requirements8,9. Clinical researchers have sought to measure these clinical effects with studies demonstrating a reduction in bispectral index (BIS) values10 or patient state index (PSI) values11 following spinal anesthesia. However, other studies did not find a significant difference in BIS values despite observed differences in levels of alertness or sedation12. Fundamentally, researchers have sought to obtain a readout able to more precisely quantify the effect of spinal anesthesia to induce sedation and reduce anesthetic requirements by using scalp electroencephalogram (EEG) recordings to measure underlying changes in voltage potentials in the brain. In this way, the EEG might measure the depth of anesthesia in order to better “explain” the clinical effects observed. A limitation of BIS and PSI is that they are processed EEG algorithms that may not account for neurodevelopmental age differences, interindividual pharmacodynamic differences, or the unique mechanisms of neuraxial anesthesia that could account for sedation. To our knowledge, EEG patterns in adults during spinal anesthesia, outside of BIS and PSI, have not been described in the literature.

Similarly, the effects of spinal anesthesia on the EEG in infants have not been well-studied. Preliminary work in infants examined EEG correlates of spinal anesthesia using EEG-derived depth-of-anesthesia monitors. Hermanns et al. obtained EEG correlates of spinal anesthesia in a cohort of 20 preterm infants using the BIS monitor13. After administration of 1 mg/kg of 0.5% hyperbaric bupivacaine with 10 μg/kg epinephrine, BIS levels were reduced, with a decrease in spectral power. Disma et al. studied 12 infants receiving 1 mg/kg 0.5% levobupivacaine using the Cerebral State Index (CSI)14. They observed a reduction in the CSI of all infants accompanied by findings consistent with burst suppression, a pattern of decreased voltage. This pioneering work obtaining neurophysiological correlates of infant spinal anesthesia inspired other investigators to build on this research. The mechanism of the sedation observed with spinal anesthesia has been hypothesized to be due to a decrease in afferent input to the reticular activating system, rather than rostral spread of local anesthetics. Of note, Holman and Puglia highlighted a case series of 4 infants with loss of corneal and eyelash reflexes after spinal anesthesia with 0.5% bupivacaine suggesting an effect on brainstem reflexes despite the lack of general anesthesia15. Corneal reflexes may be modulated by the reticular activating system as well as by natural sleep, suggesting the loss of corneal reflexes in these patients could be directly related to sleep15. The absence of the corneal reflex in younger infants could also reflect neurological pathways that are not yet fully mature, with full-term infants developing the tactile corneal reflex over the first 12 weeks of life16. Whitaker et al. obtained unprocessed EEGs in the International 10–20 System in a pilot cohort of 12 infants receiving spinal anesthesia1. All patients received 1 mg/kg of 0.5% bupivacaine (maximum 5 mg), with 4 infants receiving 1 mcg/kg of intrathecal clonidine. All infants developed a sedated state, with EEG findings most commonly demonstrating an initial voltage attenuation and background slowing, followed by the appearance of sleep spindle complexes (12–14 Hz) distributed in frontal and central leads, suggestive of physiologic Stage 2, non-rapid eye movement (NREM) sleep (Figure 1). No burst suppression patterns were observed.

Figure 1.

Figure 1.

Density spectral array demonstrating transition from the awake state to stage 2 of sleep over an 8 min period. The density of spectral power is color coded for percentage of total power as a function of frequency. Sleep spindles (12–14 Hz) are denoted by the asterisks and faint yellow density measures.

To further expand on these findings, Santa Cruz et al. obtained frontal EEG recordings in 34 infants with a median age of 11.5 weeks postmenstrual age (PMA) undergoing spinal anesthesia with 1 mg/kg of 0.5% bupivacaine with or without 1 mcg/kg of intrathecal clonidine, at the discretion of the anesthesiologist17. EEG findings consisted predominantly of slow oscillations (Figure 2). The spectrograms were visually scored for episodes of EEG discontinuity (a pattern of low voltage defined as less than 25 μvolts lasting for 2 seconds or greater) and sleep spindle activity. The authors made a distinction between gestational age, postmenstrual age, and chronological age in their analysis of EEG discontinuity and sleep spindle development, which is important because these findings vary depending on the stage of neurodevelopment of the infant18,19. The authors described age-dependent changes in the presence of EEG discontinuities (Figure 3) and sleep spindles (Figure 4) in infants under spinal anesthesia, which appeared to correspond to developmental changes in the natural sleep EEG of infants. The first transition in EEG dynamics occurred in neonates, in which the probability of discontinuities decreased to zero with increasing gestational age. These discontinuities were more likely to be observed in premature infants, who are known to exhibit discontinuous patterns of activity on their EEG during physiologic sleep18,19. Of note, EEG discontinuity is distinct from burst suppression, and frequently is not differentiated from burst suppression in the EEG-derived depth-of-anesthesia monitors. While the previous study by Disma and colleagues noted an increase in burst suppression in infants under spinal anesthesia14, it is possible that this calculated index may have been identifying EEG discontinuities as opposed to burst suppression. This is an important distinction, as EEG discontinuities can be observed in healthy preterm and term neonates up to 46 weeks PMA and are characterized by bursts of high amplitude EEG activity alternating with low amplitude (<25–50 μV) EEG activity19. In contrast, burst suppression is considered a severe disruption of EEG continuity that is characterized by bursts of EEG activity with abnormal features alternating with prolonged periods of abnormally low amplitude (<5 μV) EEG activity19 and is often associated with poor neurologic outcomes20. The second transition in EEG dynamics was related to spindle activity under anesthesia. Spindle oscillations were absent in neonates and appeared at approximately 49 weeks postmenstrual age, similar to the time when sleep spindles are observed during brain development18,19. Overall, these findings by Santa Cruz et al. are consistent with previous work showing the EEG following infant spinal anesthesia was characterized by the appearance of spindles and background slowing, suggestive of a sleep-like state1,17.

Figure 2.

Figure 2.

Spectrogram and time domain waveform of an 11-week-old premature infant (33 week gestational age) under spinal anesthesia. The spectrogram shows a dominant low-frequency (slow/delta: 0.1–4 Hz) activity. A corresponding 10-second EEG trace recorded at minute 26 featuring slow-delta oscillations is shown.

Figure 3.

Figure 3.

Spectrogram and time-domain waveform of an 11-week-old premature infant (26 week gestational age) under spinal anesthesia. The spectrogram shows an alternating pattern of burst events lasting a few seconds followed by periods of discontinuity of variable duration and amplitude. A corresponding 10-second EEG trace recorded at minute 44 shows alternating discontinuity events and high-frequency bursts.

Figure 4.

Figure 4.

Spectrogram and time-domain waveform of a 20-week-old infant (38 week gestational age) under spinal anesthesia. The spectrogram shows spindles (10–15 Hz oscillations) and slow-delta oscillation (0.1–4 Hz). A corresponding 10-second EEG trace recorded at minute 31 shows slow waves and spindles (red underlines).

Lastly, infants receiving intrathecal clonidine as an adjunct to spinal anesthesia have been observed to have a higher incidence of hiccups and mild airway obstruction compared to infants receiving bupivacaine alone, perhaps suggesting higher levels of blockade21. These airway events did not, however, result in an increased rate of conversion to general anesthesia or a longer recovery period21. Alpha-2 agonists, like clonidine and dexmedetomidine, have also been associated with slow oscillations with spindles22. Given these observations, studies are ongoing to investigate whether the addition of intrathecal clonidine as an adjunct to spinal anesthesia resulted in a potentially deeper level of sedation, with associated differences in sleep spindle characteristics observable in the EEG. Preliminary data suggest that the use of adjunctive intrathecal clonidine at a dose of 1 mcg/kg does not substantially alter the EEG properties of infants during spinal anesthesia, demonstrating that while clonidine prolongs spinal anesthetic duration, there does not appear to be identifiable differences in EEG features.

In conclusion, findings from studies to date seem to indicate that the apparent sedative state observed in infants following spinal anesthesia is most consistent with natural sleep. This sedative state is likely promoted by a shift in the balance between and sleep and wakefulness, influenced by a decrease in ascending afferent inputs to reticulo-thalamo-cortical pathways and an immature general arousal and attention system in infants23. Specifically, the EEG correlates of infant spinal anesthesia consist of: (1) global slowing in the background frequency of EEG waveforms17; (2) low voltage (or discontinuous) EEG patterns in the youngest of infants, which may account for the burst suppression detected by BIS and CSI13,14; and (3) the appearance of sleep spindles in older infants consistent with age-related observations from sleep literature1,17. No epileptiform or other abnormal findings have been reported24. Future research could further investigate EEG sleep spindle architecture and incorporate other approaches to sleep spindle detection25.

Funding

This work was supported by National Institutes of Health (NIH) National Center for Advancing Translational Science (NCATS) Einstein-Montefiore CTSA Grant No. UL1TR002556, KL2TR002558, and K23DA057499 (to J.Y.C.)

Footnotes

Disclosures

None

References

  • 1.Whitaker EE, Chao JY, Holmes GL, et al. Electroencephalographic assessment of infant spinal anesthesia: A pilot prospective observational study. Paediatr Anaesth. 2021;31(11):1179–1186. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.McCann ME, Withington DE, Arnup SJ, et al. Differences in Blood Pressure in Infants After General Anesthesia Compared to Awake Regional Anesthesia (GAS Study-A Prospective Randomized Trial). Anesth Analg. 2017;125(3):837–845. doi: 10.1213/ANE.0000000000001870 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Davidson AJ, Disma N, de Graaff JC, et al. Neurodevelopmental outcome at 2 years of age after general anaesthesia and awake-regional anaesthesia in infancy (GAS): an international multicentre, randomised controlled trial. Lancet. 2016;387(10015):239–250. doi: 10.1016/S0140-6736(15)00608-X [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Liu CA, Davis N, Kelleher CM. Application of an infant spinal anesthesia protocol in infants presenting for inguinal herniorrhaphy improves operating room and postanesthesia recovery unit utilization. Paediatr Anaesth. 2019;29(8):881–882. doi: 10.1111/pan.13686 [DOI] [PubMed] [Google Scholar]
  • 5.Chen FK, Li LT, Kelleher CM, Liu CA. Infant spinal anesthesia reduces postoperative pain scores and pain medication consumption in infants undergoing inguinal herniorrhaphy. J Pediatr Surg. 2020;55(12):2840–2843. doi: 10.1016/j.jpedsurg.2020.08.011 [DOI] [PubMed] [Google Scholar]
  • 6.Pollock JE, Neal JM, Liu SS, Burkhead D, Polissar N. Sedation during spinal anesthesia. Anesthesiology. 2000. Sep;93(3):728–34. [DOI] [PubMed] [Google Scholar]
  • 7.Gentili M, Huu PC, Enel D, Hollande J, Bonnet F. Sedation depends on the level of sensory block induced by spinal anaesthesia. Br J Anaesth. 1998. Dec;81(6):970–1. [DOI] [PubMed] [Google Scholar]
  • 8.Tverskoy M, Shagal M, Finger J, Kissin I. Subarachnoid bupivacaine blockade decreases midazolam and thiopental hypnotic requirements. J Clin Anesth. 1994. Nov-Dec;6(6):487–90. [DOI] [PubMed] [Google Scholar]
  • 9.Ben-David B, Vaida S, Gaitini L. The influence of high spinal anesthesia on sensitivity to midazolam sedation. Anesth Analg. 1995. Sep;81(3):525–8. [DOI] [PubMed] [Google Scholar]
  • 10.Nishikawa K, Hagiwara R, Nakamura K, Ishizeki J, Kubo K, Saito S, Goto F. The effects of the extent of spinal block on the BIS score and regional cerebral oxygen saturation in elderly patients: A prospective, randomized, and double-blinded study. J Clin Monit Comput. 2007. Apr;21(2):109–14. doi: 10.1007/s10877-006-9063-7. [DOI] [PubMed] [Google Scholar]
  • 11.Kurup V, Ramani R, Atanassoff PG. Sedation after spinal anesthesia in elderly patients: a preliminary observational study with the PSA-4000. Can J Anaesth. 2004. Jun-Jul;51(6):562–5. [DOI] [PubMed] [Google Scholar]
  • 12.Marucci M, Diele C, Bruno F, Fiore T. Subarachnoid anaesthesia in caesarean delivery: effects on alertness. Minerva Anestesiol. 2003. Nov;69(11):809–19, 819–24. [PubMed] [Google Scholar]
  • 13.Hermanns H, Stevens MF, Werdehausen R, Braun S, Lipfert P, Jetzek-Zader M. Sedation during spinal anaesthesia in infants. Br J Anaesth. 2006;97(3):380–384. doi: 10.1093/bja/ael156 [DOI] [PubMed] [Google Scholar]
  • 14.Disma N, Tuo P, Astuto M, Davidson AJ. Depth of sedation using Cerebral State Index in infants undergoing spinal anesthesia. Paediatr Anaesth. 2009;19(2):133–137. doi: 10.1111/j.1460-9592.2008.02859.x [DOI] [PubMed] [Google Scholar]
  • 15.Holman AE, Puglia MP. Loss of Corneal Reflex in Children Undergoing Spinal Anesthesia: A Case Series. A A Pract. 2020;14(1):9–11. [DOI] [PubMed] [Google Scholar]
  • 16.Snir M, Axer-Siegel R, Bourla D, Kremer I, Benjamini Y, Weinberger D. Tactile corneal reflex development in full-term babies. Ophthalmology. 2002. Mar;109(3):526–9. [DOI] [PubMed] [Google Scholar]
  • 17.Santa Cruz Mercado LA, Lee JM, Liu R, et al. Age-Dependent Electroencephalogram Features in Infants Under Spinal Anesthesia Appear to Mirror Physiologic Sleep in the Developing Brain: A Prospective Observational Study. Anesth Analg. Published online March 7, 2023. doi: 10.1213/ANE.0000000000006410 [DOI] [PubMed] [Google Scholar]
  • 18.Britton JW, Frey LC, Hopp JL, et al. Electroencephalography (EEG): An Introductory Text and Atlas of Normal and Abnormal Findings in Adults, Children, and Infants. (St. Louis EK, Frey LC, eds.). American Epilepsy Society; 2016. Accessed October 28, 2023. http://www.ncbi.nlm.nih.gov/books/NBK390354/ [PubMed] [Google Scholar]
  • 19.Tsuchida TN, Wusthoff CJ, Shellhaas RA, et al. American clinical neurophysiology society standardized EEG terminology and categorization for the description of continuous EEG monitoring in neonates: report of the American Clinical Neurophysiology Society critical care monitoring committee. J Clin Neurophysiol. 2013;30(2):161–173. [DOI] [PubMed] [Google Scholar]
  • 20.Grigg-Damberger MM, Coker SB, Halsey CL, Anderson CL. Neonatal burst suppression: its developmental significance. Pediatr Neurol. 1989. Mar-Apr;5(2):84–92. [DOI] [PubMed] [Google Scholar]
  • 21.Peck J, Chen A, Liu D, et al. Clonidine prolongs pediatric spinal blockade but may increase the risk of airway obstruction, hiccups, and apnea [Abstract]. In: IARS and SOCCA Abstracts 2022. Anesth Analg. 2022;134(5):1070–71. [Google Scholar]
  • 22.Purdon PL, Pavone KJ, Akeju O, Smith AC, Sampson AL, Lee J, Zhou DW, Solt K, Brown EN. The Ageing Brain: Age-dependent changes in the electroencephalogram during propofol and sevoflurane general anaesthesia. Br J Anaesth. 2015. Jul;115 Suppl 1(Suppl 1):i46–i57. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Reynolds GD, Romano AC. The Development of Attention Systems and Working Memory in Infancy. Front Syst Neurosci. 2016. Mar 3;10:15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Chao JY, Tam M, Ferrera A, et al. Epileptiform discharges, electrographic seizures, and electroclinical seizures during paediatric sevoflurane anaesthesia: a systematic review and proposal for standard definitions. Br J Anaesth. 2023;130(1):e18–e21. doi: 10.1016/j.bja.2022.09.021 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.He M, Das P, Hotan G, Purdon PL. Switching state-space modeling of neural signal dynamics. PLoS Comput Biol. 2023;19(8):e1011395. [DOI] [PMC free article] [PubMed] [Google Scholar]

RESOURCES