Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1986 Apr;55(4):336–343. doi: 10.1136/hrt.55.4.336

Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system.

R D Levy, D Cunningham, L M Shapiro, C Wright, L Mockus, K M Fox
PMCID: PMC1236735  PMID: 3964499

Abstract

A transducer tipped catheter and simple recording system were used for the continuous measurement of ambulatory pulmonary artery pressure. The pulmonary artery pressure was recorded on a miniaturised tape recorder and replayed via an optical writer. Pulmonary arterial systolic and diastolic pressures can be analysed on a beat to beat basis. Continuous ambulatory monitoring was performed for a total 288 hours in 13 patients who were undergoing routine investigation for coronary artery disease. There was less than 1% zero drift and 0.25% linearity error per full scale pressure. The frequency response of the entire system was flat to 8 Hz with a linear phase delay. The transducer tipped catheter and a conventional fluid-filled system were used to measure left ventricular and pulmonary artery end diastolic pressures in eight patients. The correlation between the results obtained by the two methods was excellent. This method could be used at any centre equipped for ambulatory electrocardiographic monitoring.

Full text

PDF
336

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BRADLEY R. D. DIAGNOSTIC RIGHT-HEART CATHETERISATION WITH MINIATURE CATHETERS IN SEVERELY ILL PATIENTS. Lancet. 1964 Oct 31;2(7366):941–942. doi: 10.1016/s0140-6736(64)90869-4. [DOI] [PubMed] [Google Scholar]
  2. Dalen J. E. Bedside hemodynamic monitoring. N Engl J Med. 1979 Nov 22;301(21):1176–1178. doi: 10.1056/NEJM197911223012110. [DOI] [PubMed] [Google Scholar]
  3. FIFE W. P., LEE B. S. CONSTRUCTION AND USE OF SELF-GUIDING, RIGHT HEART AND PULMONARY ARTERY CATHETER. J Appl Physiol. 1965 Jan;20:148–149. doi: 10.1152/jappl.1965.20.1.148. [DOI] [PubMed] [Google Scholar]
  4. Foote G. A., Schabel S. I., Hodges M. Pulmonary complications of the flow-directed balloon-tipped catheter. N Engl J Med. 1974 Apr 25;290(17):927–931. doi: 10.1056/NEJM197404252901702. [DOI] [PubMed] [Google Scholar]
  5. Ikram H., Richards A. M., Hamilton E. J., Nicholls M. G. Continuous recording of pulmonary artery pressure in unrestricted subjects. Br Heart J. 1984 Apr;51(4):421–426. doi: 10.1136/hrt.51.4.421. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Kaltman A. J., Herbert W. H., Conroy R. J., Kossmann C. E. The gradient in pressure across the pulmonary vascular bed during diastole. Circulation. 1966 Sep;34(3):377–384. doi: 10.1161/01.cir.34.3.377. [DOI] [PubMed] [Google Scholar]
  7. Nathan A. W., Perry S. G., Cochrane T., Banim S. O., Spurrell R. A., Camm A. J. Ambulatory monitoring of pulmonary artery pressure. A preliminary clinical evaluation. Br Heart J. 1983 Jan;49(1):33–37. doi: 10.1136/hrt.49.1.33. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Ratshin R. A., Rackley C. E., Russell R. O., Jr Hemodynamic evaluation of left ventricular function in shock complicating myocardial infarction. Circulation. 1972 Jan;45(1):127–139. doi: 10.1161/01.cir.45.1.127. [DOI] [PubMed] [Google Scholar]
  9. Scheinman M., Evans G. T., Weiss A., Rapaport E. Relationship between pulmonary artery end-diastolic pressure and left ventricular filling pressure in patients in shock. Circulation. 1973 Feb;47(2):317–324. doi: 10.1161/01.cir.47.2.317. [DOI] [PubMed] [Google Scholar]
  10. Sise M. J., Hollingsworth P., Brimm J. E., Peters R. M., Virgilio R. W., Shackford S. R. Complications of the flow-directed pulmonary artery catheter: A prospective analysis in 219 patients. Crit Care Med. 1981 Apr;9(4):315–318. doi: 10.1097/00003246-198104000-00006. [DOI] [PubMed] [Google Scholar]
  11. Swan H. J., Ganz W., Forrester J., Marcus H., Diamond G., Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970 Aug 27;283(9):447–451. doi: 10.1056/NEJM197008272830902. [DOI] [PubMed] [Google Scholar]
  12. Tayler D. I., Vincent R. Artefactual ST segment abnormalities due to electrocardiograph design. Br Heart J. 1985 Aug;54(2):121–128. doi: 10.1136/hrt.54.2.121. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES