Abstract
Auscultatory and echocardiographic and phonocardiographic studies were performed on 26 patients who had a total of 11 Lillehei-Kaster, 16 Björk-Shiley, and 18 St Jude heart valve prostheses functioning normally in the aortic or mitral positions or both. With all types and positions of prostheses a distinct closing sound was always detected. It was frequently heard in two parts which, according to echocardiographic and phonocardiographic studies, resulted from the onset and completion of the valve closure. An opening sound could be heard from all Björk-Shiley and St Jude valves but from only four of the 11 Lillehei-Kaster valves. The opening sounds due to mitral prostheses consisted of two to three closely spaced clicks detected as a faint early diastolic crackle on auscultation. Echocardiography with phonocardiography indicated that they were related to the onset and termination of the disc opening excursion. In the aortic position the valves always produced early to mid-systolic murmurs, and a soft early diastolic murmur was also heard in seven of 23 patients. A mid-diastolic rumble was heard in 12 of 22 patients with mitral prostheses. Normally functioning tilting disc valve prostheses produce characteristic auscultatory findings, and familiarity with these findings will be useful in clinical evaluation of patients with these prostheses.
Full text
PDF






Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Amann F. W., Burckhardt D., Hasse J., Grädel E. Echocardiographic features of the correctly functioning St. Jude Medical valve prosthesis. Am Heart J. 1981 Jan;101(1):45–51. doi: 10.1016/0002-8703(81)90382-3. [DOI] [PubMed] [Google Scholar]
- Ben-Zvi J., Hildner F. J., Chandraratna P. A., Samet P. Thrombosis on Bjork-Shiley aortic valve prosthesis. Clinical, arteriographic, echocardiographic and therapeutic observations in seven cases. Am J Cardiol. 1974 Oct 3;34(5):538–544. doi: 10.1016/0002-9149(74)90124-6. [DOI] [PubMed] [Google Scholar]
- Commerford P. J., Lloyd E. A., De Nobrega J. A. Thrombosis of St. Jude medical cardiac valve in the mitral position. Chest. 1981 Sep;80(3):326–327. doi: 10.1378/chest.80.3.326. [DOI] [PubMed] [Google Scholar]
- Copans H., Lakier J. B., Kinsley R. H., Colsen P. R., Fritz V. U., Barlow J. B. Thrombosed Björk-Shiley mitral prostheses. Circulation. 1980 Jan;61(1):169–174. doi: 10.1161/01.cir.61.1.169. [DOI] [PubMed] [Google Scholar]
- Cunha C. L., Giuliani E. R., Callahan J. A., Pluth J. R. Echophonocardiographic findings in patients with prosthetic heart valve malfunction. Mayo Clin Proc. 1980 Apr;55(4):231–242. [PubMed] [Google Scholar]
- DePace N. L., Kotler M. N., Mintz G. S., Lichtenberg R., Goel I. P., Segal B. L. Echocardiographic and phonocardiographic assessment of the St. Jude cardiac valve prosthesis. Chest. 1981 Sep;80(3):272–277. doi: 10.1378/chest.80.3.272. [DOI] [PubMed] [Google Scholar]
- Gibson T. C., Starek P. J., Moos S., Craige E. Echocardiographic and phonocardiographic characteristics of the lillehei-kaster mitral valve prosthesis. Circulation. 1974 Mar;49(3):434–440. doi: 10.1161/01.cir.49.3.434. [DOI] [PubMed] [Google Scholar]
- McClung J. A., Stein J. H., Ambrose J. A., Herman M. V., Reed G. E. Prosthetic heart valves: a review. Prog Cardiovasc Dis. 1983 Nov-Dec;26(3):237–270. doi: 10.1016/0033-0620(83)90008-7. [DOI] [PubMed] [Google Scholar]
- Mintz G. S., Carlson E. B., Kotler M. N. Comparison of noninvasive techniques in evaluation of the nontissue cardiac valve prosthesis. Am J Cardiol. 1982 Jan;49(1):39–44. doi: 10.1016/0002-9149(82)90275-2. [DOI] [PubMed] [Google Scholar]
- Najmi M., Segal B. L. Auscultatory and phonocardiographic findings in patients with prosthetic ball-valves. Am J Cardiol. 1965 Dec;16(6):794–799. doi: 10.1016/0002-9149(65)90695-8. [DOI] [PubMed] [Google Scholar]
- Nitter-Hauge S. Doppler echocardiography in the study of patients with mitral disc valve prostheses. Br Heart J. 1984 Jan;51(1):61–69. doi: 10.1136/hrt.51.1.61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Raizada V., Smith N. D., Hoyt T. W., Abrams J., Schroeder K., Desser K. B., Benchimol A. Phonocardiographic characteristics of the St. Jude prosthesis in the aortic position. Chest. 1982 Jan;81(1):95–96. doi: 10.1378/chest.81.1.95. [DOI] [PubMed] [Google Scholar]
- Sands M. J., Jr, Lachman A. S., O'Reilly D. J., Leach C. N., Jr, Sappington J. B., Katz A. M. Diagnostic value of cinefluoroscopy in the evaluation of prosthetic heart valve dysfunction. Am Heart J. 1982 Sep;104(3):622–627. doi: 10.1016/0002-8703(82)90237-x. [DOI] [PubMed] [Google Scholar]
- Smith N. D., Raizada V., Abrams J. Auscultation of the normally functioning prosthetic valve. Ann Intern Med. 1981 Nov;95(5):594–598. doi: 10.7326/0003-4819-95-5-594. [DOI] [PubMed] [Google Scholar]
- Vardan S., Warner R., Mookherjee S., Mead M., Obeid A. I. Echo- and phonocardiographic studies in patients with Lillehei-Kaster aortic valve prostheses. Jpn Heart J. 1979 May;20(3):277–288. doi: 10.1536/ihj.20.277. [DOI] [PubMed] [Google Scholar]
- Verdel G., Heethaar R. M., Jambroes G., van der Werf T. Assessment of the opening angle of implanted Björk-Shiley prosthetic valves. Circulation. 1983 Aug;68(2):355–359. doi: 10.1161/01.cir.68.2.355. [DOI] [PubMed] [Google Scholar]
- Weinstein I. R., Marbarger J. P., Pérez J. E. Ultrasonic assessment of the St. Jude prosthetic valve: M mode, two-dimensional, and Doppler echocardiography. Circulation. 1983 Nov;68(5):897–905. doi: 10.1161/01.cir.68.5.897. [DOI] [PubMed] [Google Scholar]
- Witchitz S., Veyrat C., Moisson P., Scheinman N., Rozenstajn L. Fibrinolytic treatment of thrombus on prosthetic heart valves. Br Heart J. 1980 Nov;44(5):545–554. doi: 10.1136/hrt.44.5.545. [DOI] [PMC free article] [PubMed] [Google Scholar]