To the Editor,

We thank Mordukhovich and colleagues for their thoughtful commentary [7] on our recent publication, “Is Ocular Safety in Orthopaedics Overlooked? A Systematic Review of Annual Ocular Radiation Exposure and Protective Measures” [2]. We appreciate their interest in this important occupational health topic, and we are encouraged that our findings prompted evaluation of similar risks among plastic surgeons performing fluoroscopy-intensive hand procedures. As Mordukhovich et al. stated in their letter [7], a substantial proportion of academic plastic surgeons pursue hand fellowship training, with a large share of plastic surgery hand cases involving osseous and joint procedures that are also performed by orthopaedic surgeons. This supports the rationale for cross-specialty and procedure-specific evaluation of ocular radiation exposure risks. We commend Mordukhovich and colleagues for their efforts to replicate our review methodology in the context of plastic surgery. Their finding that there were no eligible studies on ocular radiation exposure in plastic surgery underscores the pressing need for additional investigations on the topic.

While there is a relative lack of studies evaluating radiation exposure from fluoroscopy usage during hand surgery, we hope that a consolidation of our findings may provide some answers to their proposed inquiry. Among the 29 articles included in our systematic review [2], only six distinctly investigated ocular irradiation in the context of hand surgery [1, 3, 4, 6, 8, 10]. Three of these studies used matching methodologies, consisting of a phantom anthropomorphic model exposed to 15 minutes of continuous C-arm radiation to mimic a month of hand surgeon radiation exposure [3, 4, 6]. These studies found that ocular radiation was markedly increased when the C-arm was in the inverted position (nearly 3.5 times higher), but even when estimated across an entire year’s anticipated caseload, this remained below the recommended annual radiation exposure limit for the eyes [3]. Furthermore, ocular irradiation was substantially higher when the flat detector was above the table compared to below the table [6]. With a maximal rate of eye exposure of 16.7 mrem over 15 minutes, a volar plating caseload would have to be over 13,000 before exceeding the yearly limit [6]. While these exposures do not exceed the recommended annual radiation limit, we don’t know whether ocular complications might occur as a result of being exposed to radiation over decades, so the authors of these studies still recommend the use of protective equipment for surgeons’ eyes [3, 4, 6].

Additionally, only one study [1] in our review assessed radiation exposure according to the type of procedure, finding that the highest mean dose area product (Gy*cm2) occurred during reduction of fractures (0.12) and arthroscopic joint surgery (0.07). That study also stratified by type of fracture among those repaired surgically with the help of intraoperative fluoroscopy, and reported the highest maximum dose area products (Gy*cm2) among scaphoid hand fractures (0.57), metacarpal bone fractures (0.45), and both-bone forearm fractures (0.39). They concluded that while the 20 mSv annual limit for ocular irradiation is not reached in those settings, leaded ocular protective equipment should still be recommended because the risk of cataract formation is still possible considering the unknown risk of long-term exposure [4, 6]. We hope that these findings may prompt additional research regarding the ocular impacts of intraoperative fluoroscopy among hand surgeons.

While our review focused on orthopaedic procedures, particularly those with high fluoroscopic demands, we agree that risk stratification by procedure type may offer a more precise framework for assessing radiation exposure across all surgical disciplines. This is particularly relevant for hand surgery, which involves a broad range of fluoroscopy duration, commonly ranging from 1 to 152 seconds of total fluoroscopy time across various hand and wrist procedures [5, 9]. We hope that future investigations will expand upon these themes. Prospective dosimetry studies, procedure-specific and specialty-specific analyses, and cross-sectional studies should investigate the prevalence of cataracts in surgeons compared to the general population. These types of studies would more comprehensively characterize the long-term ocular risks associated with intraoperative radiation exposures. Ultimately, increased awareness and preventive strategies, such as those outlined in our review (such as sport wrap-around leaded eyewear and strategic positioning relative to fluoroscopic sources) [2], should be emphasized across all surgical disciplines that utilize intraoperative fluoroscopy.

We thank the authors of this letter [7], again, for their valuable contribution to this topic.

Footnotes

(RE: Mordukhovich I, Bassiri Gharb B, Rampazzo A. Letter to the Editor: Is Ocular Safety in Orthopaedics Overlooked? A Systematic Review of Annual Ocular Radiation Exposure and Protective Measures. Clin Orthop Relat Res. 2025;483:1784-1785.)

Each author certifies that there are no funding or commercial associations (consultancies, stock ownership, equity interest, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article related to the author or any immediate family members.

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.

The opinions expressed are those of the writers, and do not reflect the opinion or policy of CORR® or The Association of Bone and Joint Surgeons®.

Contributor Information

Keith E. Arnold, Email: kea69@case.edu.

Victoria Whitmore, Email: vew9@case.edu.

Christian J. Hecht, Email: cjh213@case.edu.

Joshua R. Porto, Email: jrp210@case.edu.

Atul F. Kamath, Email: axk1321@case.edu.

References

  • 1.Apelmann C, Kowald B, Weinrich N, et al. Radiation dose to the eye lens through radiological imaging procedures at the surgical workplace during trauma surgery. Int J Environ Res Public Health. 2019;16:3850. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Arnold KE, Whitmore V, Hecht CJ, Porto JR, Kamath AF. Is ocular safety in orthopaedics overlooked? A systematic review of annual ocular radiation exposure and protective measures. Clin Orthop. 2024;482:1954-1967. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Chapman T, Martin DP, Williamson C, Tinsley B, Wang ML, Ilyas AM. Mini C-arm fluoroscopy: does its configuration matter for radiation exposure to the surgeon? Hand (N Y). 2018;13:552–557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Hoffler CE, Ilyas AM. Fluoroscopic radiation exposure: are we protecting ourselves adequately? J Bone Jt Surg-Am Vol. 2015;97:721-725. [DOI] [PubMed] [Google Scholar]
  • 5.Mahabir RC, DeCroff CM, Thurgood L, Harrop AR. Closed reduction internal fixation rates and procedure times for metacarpal fractures treated in a minor surgery area before and after the introduction of a mini C-arm unit. Can J Plast Surg J Can Chir Plast. 2008;16:162-164. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Martin DP, Chapman T, Williamson C, Tinsley B, Ilyas AM, Wang ML. Elevated radiation exposure associated with above surface flat detector mini C-arm use. Hand (N Y). 2019;14:565–569. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Mordukhovich I, Bassiri Gharb B, Rampazzo A. Letter to the editor: is ocular safety in orthopaedics overlooked? A systematic review of annual ocular radiation exposure and protective measures. Clin Orthop Relat Res. 2025;483:1784-1785. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Romanova K, Vassileva J, Alyakov M. Radiation exposure to the eye lens of orthopaedic surgeons during various orthopaedic procedures. Radiat Prot Dosimetry. 2015;165:310-313. [DOI] [PubMed] [Google Scholar]
  • 9.van Rappard JRM, de Jong T, Hummel WA, Ritt MJPF, Mouës CM. Radiation exposure to surgeon and assistant during flat panel mini c-arm fluoroscopy in hand and wrist surgical procedures. J Hand Surg. 2019;44:68.e1-68.e5. [DOI] [PubMed] [Google Scholar]
  • 10.Wang ML, Hoffler CE, Ilyas AM, Kirkpatrick WH, Beredjiklian PK, Leinberry CF. Hand surgery and fluoroscopic eye radiation dosage: a prospective pilot comparison of large versus mini c-arm fluoroscopy use. Hand (N Y). 2017;12:21–25. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Clinical Orthopaedics and Related Research are provided here courtesy of The Association of Bone and Joint Surgeons

RESOURCES