Abstract
Nitrous acid (HONO) may be generated by heterogeneous reactions of nitrogen dioxide and direct emission from combustion sources. Interactions among nitrogen oxides and ozone are important for outdoor photochemical reactions. However, little is known of indoor HONO levels or the relationship between residential HONO, NO(2), and O(3) concentrations in occupied houses. Six-day integrated indoor and outdoor concentrations of the three pollutants were simultaneously measured in two communities in Southern California using passive samplers. The average indoor HONO concentration was 4.6 ppb, compared to 0.9 ppb for outdoor HONO. Average indoor and outdoor NO(2)concentrations were 28 and 20.1 ppb, respectively. Indoor O(3) concentrations were low (average 14.9 ppb) in comparison to the outdoor levels (average 56.5 ppb). Housing characteristics, including community and presence of a gas range, were significantly associated with indoor NO(2) and HONO concentrations. Indoor HONO levels were closely correlated with indoor NO(2) levels and were about 17% of indoor NO(2) concentrations. Indoor HONO levels were inversely correlated with indoor O(3) levels. The measurements demonstrated the occurrence of substantial residential indoor HONO concentrations and associations among the three indoor air pollutants.
Full Text
The Full Text of this article is available as a PDF (523.1 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Beckett W. S., Russi M. B., Haber A. D., Rivkin R. M., Sullivan J. R., Tameroglu Z., Mohsenin V., Leaderer B. P. Effect of nitrous acid on lung function in asthmatics: a chamber study. Environ Health Perspect. 1995 Apr;103(4):372–375. doi: 10.1289/ehp.95103372. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Geyh A. S., Xue J., Ozkaynak H., Spengler J. D. The Harvard Southern California Chronic Ozone Exposure Study: assessing ozone exposure of grade-school-age children in two Southern California communities. Environ Health Perspect. 2000 Mar;108(3):265–270. doi: 10.1289/ehp.00108265. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leaderer B. P., Naeher L., Jankun T., Balenger K., Holford T. R., Toth C., Sullivan J., Wolfson J. M., Koutrakis P. Indoor, outdoor, and regional summer and winter concentrations of PM10, PM2.5, SO4(2)-, H+, NH4+, NO3-, NH3, and nitrous acid in homes with and without kerosene space heaters. Environ Health Perspect. 1999 Mar;107(3):223–231. doi: 10.1289/ehp.99107223. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee K., Yanagisawa Y., Spengler J. D., Billick I. H. Wind velocity effects on sampling rate of NO2 badge. J Expo Anal Environ Epidemiol. 1992 Apr-Jun;2(2):207–219. [PubMed] [Google Scholar]
- Pandian M. D., Ott W. R., Behar J. V. Residential air exchange rates for use in indoor air and exposure modeling studies. J Expo Anal Environ Epidemiol. 1993 Oct-Dec;3(4):407–416. [PubMed] [Google Scholar]
- Rasmussen T. R., Brauer M., Kjaergaard S. Effects of nitrous acid exposure on human mucous membranes. Am J Respir Crit Care Med. 1995 May;151(5):1504–1511. doi: 10.1164/ajrccm.151.5.7735607. [DOI] [PubMed] [Google Scholar]
- Samet J. M., Marbury M. C., Spengler J. D. Health effects and sources of indoor air pollution. Part I. Am Rev Respir Dis. 1987 Dec;136(6):1486–1508. doi: 10.1164/ajrccm/136.6.1486. [DOI] [PubMed] [Google Scholar]
- Spengler J. D., Keeler G. J., Koutrakis P., Ryan P. B., Raizenne M., Franklin C. A. Exposures to acidic aerosols. Environ Health Perspect. 1989 Feb;79:43–51. doi: 10.1289/ehp.897943. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Spengler J. D., Koutrakis P., Dockery D. W., Raizenne M., Speizer F. E. Health effects of acid aerosols on North American children: air pollution exposures. Environ Health Perspect. 1996 May;104(5):492–499. doi: 10.1289/ehp.96104492. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Spengler J., Schwab M., Ryan P. B., Colome S., Wilson A. L., Billick I., Becker E. Personal exposure to nitrogen dioxide in the Los Angeles Basin. Air Waste. 1994 Jan;44(1):39–47. doi: 10.1080/1073161x.1994.10467236. [DOI] [PubMed] [Google Scholar]
- Spicer C. W., Kenny D. V., Ward G. F., Billick I. H. Transformations, lifetimes, and sources of NO2, HONO, and HNO3 in indoor environments. Air Waste. 1993 Nov;43(11):1479–1485. doi: 10.1080/1073161x.1993.10467221. [DOI] [PubMed] [Google Scholar]
- Suh H. H., Koutrakis P., Spengler J. D. The relationship between airborne acidity and ammonia in indoor environments. J Expo Anal Environ Epidemiol. 1994 Jan-Mar;4(1):1–22. [PubMed] [Google Scholar]
- Wainman T., Weschler C. J., Lioy P. J., Zhang J. Effects of surface type and relative humidity on the production and concentration of nitrous acid in a model indoor environment. Environ Sci Technol. 2001 Jun 1;35(11):2201–2206. doi: 10.1021/es000879i. [DOI] [PubMed] [Google Scholar]