Skip to main content
JDS Communications logoLink to JDS Communications
. 2025 Jul 17;6(5):669–674. doi: 10.3168/jdsc.2025-0755

A respirometry system designed for small ruminants

CS Silva 1, J Diavão 1, EF Motta 1, AS Silva 1, RG Tonucci 1, TR Tomich 1, FS Machado 1, MM Campos 1,*
PMCID: PMC12414371  PMID: 40922972

Graphical Abstract

graphic file with name fx1.jpg

Summary: The respirometry system presented herein consists of 3 open-circuit respiration chambers, a set of flowmeters, and gas analyzers for water vapor (H2O), carbon dioxide (CO2), methane (CH4), and oxygen (O2). The chambers are connected to air inlet and outlet pipes, delivering ambient and chamber air, respectively. Chamber air is continuously extracted and sampled by the flowmeters. Both chamber and external air samples are automatically directed to the flow multiplexer, then subsampled by a pump and analyzed for H2O, CO2, CH4, and O2 concentrations. The analyzed values, along with barometric pressure and other measurement conditions, are recorded using a data acquisition software, and can be exported for gas exchange calculations. To validate the system, gas recovery tests were conducted by injecting CO2 and CH4 at different levels and constant flow rates. The average recovery percentages ranged from 97.82% to 104.06% for CO2 and 98.70% to 101.62% for CH4 across all 3 chambers.

Highlights

  • Respiration chambers can be costly and require extensive maintenance.

  • We describe a simpler facility for respirometry studies with small ruminants.

  • The system was validated through gas recovery tests, demonstrating reliable performance.

  • The system can effectively measure gas emissions from small ruminant species.

Abstract

This technical note describes a small ruminant respiration chamber system designed to accurately quantify the production of carbon dioxide (CO2) and methane (CH4). The system consists of 3 open-circuit respiration chambers, flow meters, gas analyzers, and an accessible environmental control system. To validate its performance, gas recovery tests were conducted by injecting CO2 and CH4 at 4 constant flow rates: 0.4, 0.8, 1.2, and 1.6 standard liters per minute (SLPM) for CO2, and 0.16, 0.20, 0.24, and 0.28 SLPM for CH4. Each injection level was tested across the 3 chambers. The average percentage recoveries for CO2 and CH4 were 97.8% ± 1.46% for chamber 1, 101.1% ± 1.49% for chamber 2, and 104.1% ± 1.98% for chamber 3 and 98.7% ± 0.97% for chamber 1, 99.4% ± 2.06% for chamber 2, and 101.6% ± 2.90% for chamber 3, respectively, demonstrating the system's accuracy in quantifying livestock GHG emissions from small ruminants, such as young cattle, goats, and sheep. Therefore, this system represents a viable methodology for nutritional and environmental studies with small ruminants. Future studies conducted in this facility can contribute to a better understanding of the dynamic and flow of GHG emissions in small ruminants and target measures to increase the sustainability of small ruminant production systems.


Livestock is a major contributor to GHG emissions, accounting for 7.1 billion tonnes of carbon dioxide (CO2) equivalent annually, or 14.5% of all human-induced emissions (FAO, 2024). Enteric fermentation, particularly methane (CH4) production, is the largest source of these emissions; more importantly, CH4 has a global warming potential 28 to 36 times greater than that of CO2 over a 100-year period (IPCC, 2023). Therefore, developing nutritional strategies that enhance feed efficiency in domestic ruminants while reducing CH4 output is key. This requires precise measurements of gaseous exchanges from fermentation and nutrient oxidation, highlighting the importance of specialized tools such as open-circuit respiration chambers.

Respiration chambers are widely recognized as the “gold standard” for assessing gaseous exchanges and energy metabolism in ruminants (Troy et al., 2016). Although predominantly used in studies with large ruminants, accounting for 56% of applications (Della Rosa et al., 2021), respiration systems designed for small ruminants offer substantial potential. Their advantages include lower experimental costs and labor requirements, the use of small ruminants as models to refine energy feed fraction analysis—thereby reducing errors in diet formulation—and the selection of efficient animals through precise measurements of dietary energy losses, heat production, and energy retention (VandeHaar, 2016). Small respiration systems help validate conventional models that may overlook specific animal types, causing estimation errors. They also enable the assessment of CH4 and CO2 emissions and support research aimed at reducing the environmental impact of small ruminant production.

This technical note introduces a cost-effective and simplified respiration system specifically designed for studies involving small ruminants. We hypothesized that this system can successfully recover CO2 and CH4 emitted by small ruminants, such as young cattle (up to 200 kg), goats, and sheep. Our objective is to describe and validate this system through recovery tests of CH4 and CO2, offering an accessible and reliable alternative for measuring small ruminant GHG emissions.

The respiration chambers are housed in the Multiuser Laboratory for Livestock Bioefficiency and Sustainability at the Brazilian Agricultural Research Corporation, Embrapa, located in Coronel Pacheco, Minas Gerais, Brazil (https://www.embrapa.br/laboratorio-multiusuario-de-bioeficiencia-e-sustentabilidade-da-pecuaria). The system is set up as an open-circuit respiration system consisting of 3 chambers (Ponta, Betim, MG, Brazil), a set of flow meters (FlowKit FK-500, Sable Systems International, Las Vegas, NV), and CO2 (CA-10 Carbon Dioxide, Sable Systems International), CH4 (MA-10 CH4, Sable Systems International), and water vapor (RH-300, Sable Systems International) analyzers. The MA-10 CH4 and CA-10 CO2 models employ dual-wavelength nondispersive infrared detection, utilizing a solid-state, electrically modulated true blackbody infrared source. The chambers' walls are made of aluminum and transparent polyethylene terephthalate glycol to allow visual contact between animals (Figure 1), minimizing animal stress while enhancing internal visualization for the chamber operator.

Figure 1.

Figure 1

Diagram of the respirometry chamber designed for small ruminants. A: respirometry chamber (aluminum-polyethylene structure); B: air inlet pipe; C: punctured PVC pipes connected to air inlet; D: punctured PVC pipes connected to air outlet; E: air outlet and filter box; F: metal cage; G: feed bin attached to metal cage; H: water trough attached to metal cage; I: air conditioning unit; J: thermo-hygrometer; K: dehumidifier; L: air circulation fan attached to internal chamber wall. Created in BioRender.com.

The chambers are fitted with one rubber-sealed front door for animal access. Fresh air is drawn from outside the building into the chamber through a 75-mm-diameter polyvinyl chloride (PVC) pipe connected to fresh air inlets onto the front end of the ceiling (Figure 1B). Inside the chamber, the fresh air inlet is fitted with a valve and a T-connection connected by 2 horizontal PVC tubes (50 mm diameter × 1.34 m) punctured with 1-cm holes to avoid laminar flow (Figure 1C). The chamber's air is continuously collected into 75-mm PVC pipes, also punctured with 1-cm holes (Figure 1D), connected to an air outlet and a filter box (CSL-849–100HC, Solberg Manufacturing Inc., Itasca, IL), placed on the rear section of the ceiling (Figure 1E). These are directly coupled to a mass flow meter integrated with a sealed rotary pump capable of sustaining an airflow rate from 75 to 500 L/min (FlowKit Model FK-500, Sable International Systems, Las Vegas, NV).

The chambers are provided with a metal cage (1.85 m long × 1.14 m wide × 1.04 m high; Ponta, Betim, MG, Brazil) where animals are placed during respiration measurements (Figure 1F). The cage is enclosed with a galvanized steel screen, has a rubber mat floor, and is equipped with a feed bin and drinker (Figure 1G and H). An air-conditioning unit is installed in the upper-middle section of the chamber (Figure 1I) to regulate the internal temperature, which is continuously monitored using a digital thermo-hygrometer (Figure 1J; THU-100, Unity Instrumentos, São Paulo, SP, Brazil). A dehumidifier (model 160, Arsec Desumidificadores, Vargem Grande Paulista, SP, Brazil), placed next to the front door inside the chamber (Figure 1K), is used to control humidity. To ensure uniformity, the chamber air is constantly circulated by a fan (Figure 1L). The net volume of the chambers is 5.95 m3 (2.41 m long × 1.42 m wide × 1.74 m high). The internal pressure of the chambers is measured each morning before the commencement of gas flow measurements using a digital pressure indicator (DPI 705, Druck Limited, Leicester, UK). This procedure is conducted to verify the integrity of the chamber seal and ensure there is no gas leakage. A slight negative pressure reading on the indicator confirms that the chamber is adequately sealed. After streaming up the air outlet, the air flows through a 51-mm-diameter flexible polyurethane hose, next to the analysis room, and is collected directly by the mass flow meter. The flow is typically set at 1 L/kg of BW per min but can be adjusted based on the specific conditions of the animals undergoing respirometry evaluations (e.g., maintenance vs. production levels). Most importantly, the selected flow rate must ensure accurate gas concentration measurements by the analyzers, safeguard the animals from elevated CO2 levels, maintain measurable concentrations of target gases, and generate negative pressure within the chambers to prevent gas leakage. Accordingly, all chambers operate under negative pressure.

The flow meter, which measures incoming air from the chambers, is set to a flow rate of 0.5 L/min, with acceptable variations ranging from 0.45 to 0.55 L/min. This subsampled flow is directed to an 8-channel gas switching system (RM-8 Flow Multiplexer, Sable Systems International). There, a subsampling pump draws gas at 0.2 L/min through a sampling manifold (T-connection). Ambient (baseline) air is also continuously sampled at the same flow rate by a positive pressure pump (B-pump, Sable Systems International).

The multiplexer automatically switches from one chamber air stream to another or to external air during recordings at a defined interval, which is set via the data acquisition software Expedata (Expedata Data Analysis Software 1.9.27, version PRO, Sable Systems International). The system is currently programmed to switch channels every 300 s, from baseline (external air) to chambers 1, 2, and 3 and back to baseline (Figure 2). Therefore, the time required for a full measuring cycle with the 3 chambers working simultaneously is 20 min.

Figure 2.

Figure 2

Schematic diagram of the respirometry system designed for small ruminants and critical steps for proper gas exchange measurements. Created in BioRender.com.

Chamber and baseline air samples are individually delivered by the multiplexer to a diaphragm subsampling pump (SS4 Sub-Sampler Pump, Sable Systems International), which sequentially delivers the respective subsample to water vapor (RH-300 Water Vapor Analyzer, Sable Systems International), CO2, and CH4 analyzers at a flow rate of 0.2 L/min. All tubing from the subsampling pumps to the gas analyzers uses Bev A-Line IV tubes, size B5 (Excelon, Long Hill Township, NJ). The gas analyzers have internal temperature control and barometric pressure compensation, so the readout is already corrected to standard temperature and pressure (STP) conditions. The detection range, absolute accuracy, and resolution for relative humidity, CO2, and CH4 are humidity (detection range: 0%–100% range, accuracy: 2%, resolution: 0.001%), CO2 (0–10%, accuracy: 1%, resolution: 0.0001%), and CH4 (0%–10%, accuracy: 1%, resolution: 0.001%).

The gas analyzers must be calibrated (zeroed and spanned) both before and during respiration trials, following the instructions provided in each device's user manual. The CO2 and CH4 analyzers are calibrated daily, before the start of measurements, whereas the water vapor analyzer is calibrated once a week. The weekly calibration schedule for the water vapor analyzer accounts for environmental variations, such as changes in temperature and humidity, which can fluctuate between weeks and influence the characteristics of the sampled air (Lighton, 2018). The CO2 and CH4 analyzers are zeroed using nitrogen gas with 99.999% purity, and spanned with a calibration gas mixture containing 0.5% CO2 and 0.1% CH4 in nitrogen as the carrier gas. The water vapor analyzer is zeroed with the dry ambient air scrubbed of moisture with magnesium perchlorate [Mg(ClO4)2; Smith, 1962], and the span value is calculated using the equation proposed by Lighton (2018):

WVP = BP × [(F'iO2 − FiO2)/FiO2],

where WVP is the water vapor pressure in the same units as barometric pressure (kPa); BP is the barometric pressure; and F'iO2 and FiO2 are O2 fractional concentrations of dry and wet ambient air, respectively.

Measurement conditions such as wet air flow rate, temperature, barometric pressure, water vapor pressure, and gas concentrations are recorded by the software Expedata via a data acquisition interface. The software uses a macro utility to correct the effect of water vapor, lag time, and drift on flow rate and gas concentrations (Machado et al., 2016). The recorded data are exported to an Excel (Microsoft Corp.) spreadsheet and used to calculate CO2 and CH4 production. To ensure reliable results, animals are assessed over 24 h in each chamber by 2 consecutive days, and the average CO2 and CH4 values are used as the final respiration measurements. Feed intake within the chamber is compared with the animal's average intake during the week preceding the respiration trial. If intake drops by more than 5%, the respiration measurements are repeated until 2 validated days are obtained, as described by Machado et al. (2016).

A recovery test is performed on the entire system before and after data acquisition as recommended by Mesgaran et al. (2020). The test involves injecting known volumes of CO2 (99.990% purity, White Martins, Rio de Janeiro, RJ, Brazil) and CH4 (99.995% purity, White Martins) separately into each chamber for 4 h and calculating the volume of gas recovered after 22 h. This was selected to reflect the experimental routine, as the gas exchange measurements accommodate essential management tasks—such as changing the bedding, cleaning feeders and drinkers, assessing animal health, feeding, and sample collection if necessary—that occur daily from 0600 to 0800 h.

In routine gas recovery checks, the flow rates for gas injections are typically set at 1.0 L/min for CO2 and 0.25 mL/min for CH4. In our laboratory, the flow rate is regulated by a mass flow meter with a maximum flow rate of 50 L/min (MC-50SLMP-D/5M, Alicat Scientific Inc., Tucson, AZ). For the present validation, we conducted a series of recovery tests using 4 levels of injection CO2 (0.4, 0.8, 1.2, and 1.6 standard liters per minute; SLPM) and CH4 (0.16, 0.20, 0.24, and 0.28 SLPM) across the 3 chambers. These injection volumes were selected to represent the average daily CO2 and CH4 emissions from suckling calves (Lage et al., 2019), weaned calves (L. D. Ferreira, Federal University of Minas Gerais, Belo Horizonte, Brazil; unpublished data), and adult sheep (Sousa et al., 2022), based on previous experiments carried out at the same facility using these 3 animal categories.

The recovery tests were conducted following the standard operating procedure, after calibrating the water vapor and gas analyzers. Expedata files generated after 22 h of reading were processed using the macro utility feature of the software. Upon completion of the analysis, the software generated an Excel spreadsheet containing the percentages of CO2 and CH4 in outgoing (chamber air) and incoming (ambient) air samples, as well as the flow rate, set as 100 L/min, for each cycle (5 min) with a temperature inside the chamber set as 22°C.

These concentrations were then used to calculate the chambers' correction factor for CO2 or CH4 production (i.e., injection) using the following formula:

gasproductionCO2orCH4,LLminmin=gasvolumeoutgoingair×outgoingSTPD-gasvolumeingoingair×ingoingSTPD,

where gas volume in outgoing and ingoing air correspond to ingoing CO2 (CO2i%), ingoing CH4 (CH4i%), and outgoing CO2 (CO2e%) or outgoing CH4 (CH4e%) in the Expedata report sheet, divided by 100; outgoing standard temperature pressure and dry volume (SPTD) represents the flow rate (L/min); and ingoing SPTD corresponds to the outgoing SPTD × nitrogen factor. The SPTD conditions were estimated based on chamber volume, pressure of 101.325 kPa, and 273 kelvin.

When the volumes of O2 consumed and CO2 produced are not equal (e.g., the respiratory quotient is not 1.00) or gasses like CH4 are emitted to chamber air (or both), the ingoing and outgoing air volume will differ. To correct for this, the ingoing airflow is calculated as the outgoing standard temperature and pressure dry (STPD) multiplied with the nitrogen factor. The nitrogen factor is the ratio between the concentration of nitrogen gas leaving and entering the respiration chamber. This calculation assumes that the same amount of STPD N2 gas enters and leaves the chamber. The concentrations of nitrogen gas are calculated as 100% minus the concentrations of O2, CO2, and CH4 (Mesgaran et al., 2020).

The nitrogen (N) factor was calculated as

Nfactor%=100-CO2outgoing-O2outgoing-CH4outgoing100-CO2ingoing-O2ingoing-CH4ingoing.

The gas production calculated in the previous equation was used to determine the gas production per cycle (L/cycle), where

gasproductionpercycleL/cycle=gasproductionL/min×timepercyclemin.

Considering that each cycle corresponds to a 10-min run for one chamber (i.e., chamber air plus baseline), the time per cycle used in the above equation was 10, 15, or 20 min, depending on the number of chambers being evaluated simultaneously. The gas production per cycle was then used to estimate the 22-h cumulative gas production (i.e., injection) as follows:

Pcumulativen=Pn+Pcumulativen-1,

where Pcumulative(n) is the cumulative gas production at cycle n, Pn is the gas production in cycle n, Pcumulative(n−1) is the cumulative gas production up to the previous cycle (n − 1).

To start the calculation, the value of the first cycle (Pcumulative(1)) was equal to the production of the cycle itself:

Pcumulative1=P1.

After the cumulative gas production was determined, the volume of gas recovered from an individual chamber (i) was given as the maximum value of cumulative gas production in the respective chamber. Last, the gas recovery percentage (correction factor) was calculated as

correctionfactor%=volumeofgasrecoveredfromchamberivolumeofgasinjectedintochamberi×100.

Gerrits et al. (2018) emphasized the importance of conducting and reporting recovery tests for respiration trial results to ensure acceptable recovery ranges, whether using chamber or nonchamber techniques. Gardiner et al. (2015), for instance, used an ultra-high-purity CH4 standard and examined 3 sources of experimental error—analyzer error, ducting efficiency (including airflow measurements), and chamber mixing—to evaluate the gas recoveries in 22 chambers across 6 facilities. There was a large variation in gas recovery for the different chamber systems and testing conditions, with recovery percentages ranging from 59% to 115%.

In our current recovery tests, average recoveries across different CO2 and CH4 injection levels were 98.26% ± 0.87% for chamber 1, 100.31% ± 1.59% for chamber 2, and 102.84% ± 1.79% for chamber 3 (Table 1). Unlike Gardiner et al. (2015), our results show minimal deviation from complete gas recovery, indicating that our chamber system provides accurate measurements of gas emissions from ruminants weighing up to 200 kg, which typically emit an average 88–429 L/d of CO2 and 34–64 L/d of CH4. However, due to the limitations of our mass flow controller, we were unable to quantify lower CH4 injection volumes (<0.16 SPLM). Therefore, we cannot confirm reliability for CH4 emissions below 33 L/d.

Table 1.

Gas recovery for carbon dioxide (CO2) and methane (CH4) injected into a respiration system with 3 small chambers

Chamber no. and selected gas Flow rate (SLPM1) Injected gas volume (L) Recovered gas volume (L) Recovery (%)
1
 CO2 0.40 94.76 90.66 95.67
 CO2 0.80 175.78 173.4 98.65
 CO2 1.20 291.43 285.98 98.13
 CO2 1.60 429.17 424.19 98.84
 CH4 0.16 35.93 35.09 97.66
 CH4 0.20 44.25 43.4 98.08
 CH4 0.24 57.3 57.1 99.65
 CH4 0.28 62.12 61.75 99.40
2
 CO2 0.40 96.6 95.8 99.17
 CO2 0.80 180.48 183.99 101.94
 CO2 1.20 267.39 274.36 102.61
 CO2 1.60 335.8 338.95 100.94
 CH4 0.16 35.45 35.05 98.87
 CH4 0.20 43.65 42.4 97.14
 CH4 0.24 54.66 54.49 99.69
 CH4 0.28 62.96 64.29 102.11
3
 CO2 0.40 88.4 89.96 101.76
 CO2 0.80 179.37 185.92 103.65
 CO2 1.20 266.69 278.08 104.27
 CO2 1.60 352.54 375.70 106.57
 CH4 0.16 34.86 33.95 97.39
 CH4 0.20 44.02 45.12 102.50
 CH4 0.24 52.85 54.21 102.57
 CH4 0.28 61.76 64.25 104.03
1

Standard liters per minute.

The highest CO2 recovery observed (106.57% at a 1.60 SPLM flow rate) was due to an inward CO2 leak from the chamber floor, as later confirmed scrubbing the floor with soap. Such gas contamination can lead to overestimations in open-circuit respiration chambers (Gardiner et al., 2015). Recovery tests should ideally be repeated whenever CO2 or CH4 recoveries fall below 95% or exceed 105%.

During system validation, several critical control points and potential sources of error were identified that should be routinely monitored in similar chamber-based experimental systems. These include the following: (1) Inspect door seals, pipes, wall structure, and bolts for leaks. (2) Check the chamber floor for cracks or porosity that could lead to gas leaks. (3) Ensure the mass flow meter meets injection requirements; the injection level may be lower than the equipment's minimum flow control. (4) Calibrate analyzers correctly, especially zeroing and spanning the water vapor analyzer to prevent incorrect readings. (5) Confirm that flow readings match the set point on the chamber's flow meter (FlowKit). (6) Verify calculations to ensure all input parameters align with test settings (e.g., number of chambers analyzed, reading time for a full cycle, chamber transitions). (7) Adjust input parameters in Expedata and macros to match current test conditions.

Our results demonstrate that the described respiration system is a reliable and effective tool for quantifying greenhouse gas emissions in small ruminant research, including studies focused on emission profiling and evaluating mitigation strategies.

Notes

This work was funded by the Funding Authority for Studies and Projects (FINEP, Rio de Janeiro, Brazil) and the Foundation for Research Support of the State of Minas Gerais (FAPEMIG, Belo Horizonte, Brazil).

This article does not contain any studies with human or animal subjects and did not require the Embrapa Dairy Cattle Animal Care and Use Committee approval.

The authors have not stated any conflicts of interest.

Nonstandard abbreviations used: PVC = polyvinyl chloride; SLPM = standard liters per minute; SPTD = standard temperature pressure and dry volume; STP = standard temperature and pressure; STPD = standard temperature and pressure dry.

References

  1. Della Rosa M.M., Jonker A., Waghorn G.C. A review of technical variations and protocols used to measure methane emissions from ruminants using respiration chambers, SF6 tracer technique and GreenFeed, to facilitate global integration of published data. Anim. Feed Sci. Technol. 2021;256 doi: 10.1016/j.anifeedsci.2021.115018. [DOI] [Google Scholar]
  2. FAO (Food and Agriculture Organization) Greenhouse gas emissions from agrifood systems—Global, regional and country trends, 2000–2022. 2024. https://openknowledge.fao.org/handle/20.500.14283/cd3167en Accessed Jan. 23, 2024.
  3. Gardiner T.D., Coleman M.D., Innocenti F., Tompkins J., Connor A., Garnsworthy P.C., Moorby J.M., Reynolds C.K., Waterhouse A., Wills D. Determination of the absolute accuracy of UK chamber facilities used in measuring methane emissions from livestock. Measurement. 2015;66:272–279. doi: 10.1016/j.measurement.2015.02.029. [DOI] [Google Scholar]
  4. Gerrits W.J.J., Labussière E., Reynolds C.K., Metges C.C., Kuhla B., Lund P., Weisbjerg M.R., Dijkstra J. Letter to the Editor: Recovery test results as a prerequisite for publication of gaseous exchange measurements. J. Dairy Sci. 2018;101:4703–4704. doi: 10.3168/jds.2017-13705. [DOI] [PubMed] [Google Scholar]
  5. IPCC . In: Climate Change 2023: Synthesis Report. Contribution of Working Groups I, II and III to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change. Core Writing Team, Lee H., Romero J., editors. IPCC; Geneva, Switzerland: 2025. Climate change 2023: Summary for policymakers. pp. 1–34. [DOI] [Google Scholar]
  6. Lage C.F.A., Coelho S.G., Diniz Neto H.C., Malacco V.M.R., Rodrigues J.P.P., Sacramento J.P., Machado F.S., Pereira L.G.R., Tomich T.R., Campos M.M. Relationship between feed efficiency indexes and performance, body measurements, digestibility, energy partitioning, and nitrogen partitioning in pre-weaning dairy heifers. PLoS One. 2019;14 doi: 10.1371/journal.pone.0223368. 10.1371/journal.pone.0223368 [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Lighton J.R.B. 2nd ed. Oxford University Press; 2018. Measuring Metabolic Rates: A Manual for Scientists. [DOI] [Google Scholar]
  8. Machado F.S., Tomich T.R., Ferreira A.L., Cavalcanti L.F.L., Campos M.M., Paiva C.A.V., Ribas M.N., Pereira L.G.R. Technical note: A facility for respiration measurements in cattle. J. Dairy Sci. 2016;99:4899–4906. doi: 10.3168/jds.2015-10298. 27016825. [DOI] [PubMed] [Google Scholar]
  9. Mesgaran S.D., Hellwing A.L.F., Lund P., Derno M., Kuhla B., Heetkemp M., Miller G., Humphries D., Anglard F., Rochette Y., Martin C., Gardiner T., Coleman M. In: Chapter 9 in Methods in Cattle Physiology and Behavior Research – Recommendations from the SmartCow Consortium. Mesgaran S.D., Baumont R., Munksgaard L., Humphries D., Kennedy E., Dijkstra J., Dewhurst R., Ferguson H., Terré M., Kuhla B., editors. PUBLISSO; Germany: 2020. The gas recovery test of respiratory chambers.10.5680/mcpb010 [Google Scholar]
  10. Smith G.F. The regeneration of spent magnesium perchlorate desiccant. Talanta. 1962;9:65–70. doi: 10.1016/0039-9140(62)80253-7. [DOI] [Google Scholar]
  11. Sousa L.B., Albuquerque Pereira M.L., de Oliveira Silva H.G., Sousa L.B., e Silva L.S., Machado F.S., Tomich T.R., Oss D.B., Ferreira A.L., Campos M.M., Costa I.C., Ribeiro Pereira L.G. Prosopis juliflora piperidine alkaloid extract levels in diet for sheep change energy and nitrogen metabolism and affect enteric methane yield. J. Sci. Food Agric. 2022;102:5132–5140. doi: 10.1002/jsfa.11864. 35279834. [DOI] [PubMed] [Google Scholar]
  12. Troy S.M., Duthie C.-A., Ross D.W., Hyslop J.J., Roehe R., Waterhouse A., Rooke J.A. A comparison of methane emissions from beef cattle measured using methane hoods with those measured using respiration chambers. Anim. Feed Sci. Technol. 2016;211:227–240. doi: 10.1016/j.anifeedsci.2015.12.005. [DOI] [Google Scholar]
  13. VandeHaar M.J. Proc. TriState Dairy Nutrition Conference, Fort Wayne, IN. The Ohio State University; Columbus, OH: 2016. Understanding the physiological aspects to improving feed efficiency in dairy cows. pp. 27–34. [Google Scholar]

Articles from JDS Communications are provided here courtesy of Elsevier

RESOURCES