Abstract
Purpose
Different contact lens (CL) materials have been associated with different behaviors of pre-lens tear film components in the short term. The purpose of this randomized crossover and double-masked study was to compare the effect of wearing hydrogel and silicone hydrogel CLs on pre-lens tear film status.
Methods
Soft CL wearers were recruited and randomly fitted with a hydrogel (omafilcon A) and a silicone hydrogel (stenfilcon A) CL. Tear evaporation rate, non-invasive tear break-up time (NIBUT), tear film lipid layer thickness, and partial blink rate were measured without CLs and 30 minutes after the insertion of CLs. The outcomes were analyzed using repeated measures analysis of variance or the Friedman test.
Results
Twenty-four CL wearers (6 men and 18 women) aged 23.3 3.9 years were included. Tear evaporation rate was higher with the hydrogel CL (98.6 59.4 g/m2/h; P = 0.043) and the silicone hydrogel CL (99.7 60.6 g/m2/h; P = 0.037) compared to no CL wear (69.9 41.3 g/m2/h). NIBUT was lower (P = 0.019) with the silicone hydrogel CL (12.7 6.2 s) than with no CL wear (18.5 9.8 s). Lipid layer thickness was lower with the hydrogel CL (64.9 15.5) than with the silicone hydrogel CL (75.8 14.0; P 0.001) and no CL wear (75.9 14.2; P = 0.001). No statistically significant differences were found in the partial blink rate.
Conclusion
This study demonstrated that both hydrogel and silicone hydrogel CLs disrupt the tear film by increasing tear evaporation and causing tear film instability. However, CL materials affect the pre-lens tear film status differently. Further studies with longer wearing times are required.
Keywords: Hydrogel Contact Lens, Lipid Layer Thickness, Pre-Lens Tear Film, Tear Break-up Time, Tear Evaporation Rate
INTRODUCTION
Contact lens (CL) wear divides the tear film into pre-lens and post-lens layers, causing a decrease in pre-lens thickness ranging from 2 to 7 µm.[1,2] The insertion of a CL also induces changes in the composition and concentration of some tear film components,[3,4,5] altering clinical parameters such as tear stability, lipid layer thickness, and tear evaporation rate.[3] These biophysical changes have been previously related to CL discomfort symptoms.[3]
Tear film stability in CL wearers is commonly evaluated using non-invasive tear break-up time (NIBUT) measurement, which can predict CL discomfort.[6,7,8] Previous studies have found a NIBUT decrease ranging from 5 to 7 seconds in symptomatic CL wearers compared to asymptomatic ones.[7,9] It has also been reported that shorter NIBUT values are related to CL discomfort symptoms in both hydrogel and silicone hydrogel CL wearers.[3,9] This reduction in NIBUT may be due to the reduced stability of the pre-lens tear film.[10] Additionally, the lipid layer thickness is reduced in CL wearers,[11,12] which in turn can decrease tear film stability, leading to an increased rate of tear evaporation.[3] Specifically, when a CL is worn, the tear evaporation rate can increase by 1.2 to 2.6 times compared to when no CL is used.[13] Therefore, CL wear can affect several aspects of the tear film that could lead to CL discomfort.
In addition to assessing the tear film during CL fitting, it is important to consider blinking dynamics, as its primary function is to evenly distribute the tear film across the ocular surface, creating a smooth and uniform surface for clear vision.[14] A blink is considered partial when 67% of the cornea is covered.[3] Partial blinks are associated with CL discomfort and ocular dryness symptoms,[3] possibly due to destabilizing the tear film and increasing the tear evaporation rate. Some studies have found no differences in the partial blink rate between hydrogel CL wearers and non-wearers.[3] However, another study suggested that partial blinking is higher in CL wearers.[15] Therefore, further research is needed on the relationship between different CL types and blink rate.[16]
Finally, the interaction between the CL and the pre-lens tear film also depends on the CL material. Silicone hydrogel CLs are more permeable to oxygen than hydrogel CLs. However, these materials might be more hydrophobic, which directly affects tear film properties.[17] There are reports on differences in tear film stability between hydrogel and silicone hydrogel CLs.[9,18,19] Nevertheless, limited data exist about their effect on the tear evaporation rate and lipid layer thickness during CL wear. Therefore, the present study aimed to compare the short-term effects of wearing hydrogel and silicone hydrogel CLs on pre-lens tear film status, as well as to evaluate tear film parameters in the absence of CL wear.
METHODS
This research was approved by an independent ethics committee (the East Valladolid Health Area Ethics Committee, Valladolid, Spain, code: PI 21-2491) and conformed to the principles and applicable guidelines for the protection of human participants in biomedical research.
This prospective, randomized, crossover, double-masked study was performed in compliance with the tenets of the Declaration of Helsinki. Written informed consent was obtained from participants prior to enrollment.
Subjects and Study Design
We recruited spherical single vision CL wearers over 18 years of age with a refraction between –0.25 and –12.00 diopters (D), since this was the available negative power range for the CLs used. The exclusion criteria were any alteration or ocular anomaly contraindicating the use of CLs, including history of ocular surface disease or meibomian gland dysfunction, history of any ocular surgery, any change in systemic medication affecting the tear film within the last 3 months, pregnancy, and breastfeeding. This information was collected in the anamnesis prior to the clinical tests.
Two different hydrogel daily disposable CLs were used in the study: a hydrogel CL (omafilcon A; Proclear 1 Day, CooperVision Laboratories, Pleasanton, CA, USA) and a silicone hydrogel CL (stenfilcon A; MyDay, CooperVision Laboratories, Pleasanton, CA, USA). The technical parameters of both CLs are detailed in Table 1.
Table 1.
Technical specifications of the contact lenses (CLs) used in the study
| Hydrogel CL | Silicone hydrogel CL | |
| Laboratory | CooperVision | CooperVision |
| Replacement | Daily disposable | Daily disposable |
| Design | Single vision | Single vision |
| Material | Omafilcon A | Stenfilcon A |
| Technology | PC Technology | Aquaform |
| Diameter (mm) | 14.2 | 14.2 |
| Base curve (mm) | 8.7 | 8.4 |
| Water content (%) | 60 | 54 |
| Data obtained from https://coopervision.es | ||
Volunteers attended the study visit without having used any CL for at least 24 hours before. First, the inclusion and exclusion criteria were checked, and the clinical evaluation was performed without CL wear. Second, participants were randomly fitted with one of the CLs (hydrogel or silicone hydrogel CL) in a double-masked fashion. After 30 minutes, the clinical evaluation was performed with the first CL in place. Then, the other study CL was fitted, and the same clinical evaluation was performed after 30 minutes of CL wear.
Clinical Evaluation
Using the Contact Lens Dry Eye Questionnaire (CLDEQ)-8, we evaluated the discomfort symptoms participants experienced with their habitual CLs. The cut-off value of this scale to detect symptomatic CL wearers is a score 12.[20]
The tear evaporation rate was evaluated using a closed-chamber evaporimeter, the Eye-VapoMeter (Delfin Technologies Ltd, Kuopio, Finland). Participants were first instructed to blink normally and maintain their primary gaze position while three consecutive measurements were taken. Then, they were asked to keep their eyes closed while another three consecutive measurements were performed. The mean for both scenarios was calculated. The tear evaporation rate was determined as the difference between both means, thereby eliminating the effect of eyelid skin and surrounding tissue evaporation to avoid bias in measuring this rate.
Tear film stability was evaluated by measuring the NIBUT using the EasyTear VIEW+ (EasyTear Ltd., Rovereto, Trento, Italy). Participants were asked to blink three times before the measurement was acquired. Three measurements were performed, and the mean value was recorded.
Lipid layer thickness and partial blink rate were evaluated with the LipiView II interferometer (Johnson & Johnson Vision, Santa Ana, CA, USA). Participants were asked to blink normally while a 20-second video was captured. The mean value of the lipid layer thickness and the percentage of partial blinks were recorded. All clinical measurements were performed first without CLs and then with each of the two CLs.
Statistical Analysis
The R statistical package (version 4.1.2) was used to perform the statistical analysis. A minimum sample size of 19 participants was estimated to detect an effect size of 0.83 in tear evaporation rate using a paired Student's T-test, with a statistical power of 80% and a significance level of 0.05/3 (adjusted for multiple comparisons). Using the data reported by Thai et al,[21] we calculated the effect size by considering the change in tear evaporation rate from no lens wear to Omafilcon A wear (8.99 10.89 g/m2/h). Differences between the three situations (data obtained without CLs, with hydrogel CLs, and with silicone hydrogel CLs) were analyzed using a repeated measures analysis of variance (ANOVA). Both eyes were evaluated, but only one eye was randomly selected for statistical analysis. The assumptions of normality and sphericity were checked using the Shapiro-Wilk test and the Mauchly test, respectively. Normal variables were the tear evaporation rate and lipid layer thickness. Parameters that did not meet the previous assumptions (NIBUT and blink rate) were analyzed using the Friedman test. Post-hoc pairwise comparisons were assessed using the paired Student's T-test. Alternatively, the non-parametric Wilcoxon test was used when normality assumptions were not met, with the Hommel correction applied for multiple comparisons.[22] P-values 0.05 were considered statistically significant. Data were presented as mean standard deviation.
RESULTS
Subjects
Twenty-four hydrogel CL wearers (6 men and 18 women) with a mean age of 23.3 3.9 years (range, 20 to 37 years) were included in the study. The average CL use before the study was 8.5 5.3 years (range, 0.9 to 24 years) while the average CL wearing time was 5.4 1.9 days per week (range, 1 to 7 days) and 8.5 3.1 hours per day (range, 2 to 15 hours). The mean CL power was –3.75 2.25 D (range –1.00 to –10.50 D), and the average CLDEQ-8 score was 6.8 4.6 (range, 0 to 15). Five participants were symptomatic CL wearers according to the CLDEQ-8.
Clinical Evaluation
There were significant differences in tear evaporation rate measurements, as determined by ANOVA (P = 0.012). The multiple comparisons [Figure 1A] revealed a statistically significant increase in tear evaporation rate with both the hydrogel CL (98.6 59.4 g/m2/h; P = 0.043) and the silicone hydrogel CL (99.7 60.6 g/m2/h; P = 0.037), compared to the no CL condition (69.9 41.3 g/m2/h). However, no differences were found between the two CL materials (P = 0.900).
Figure 1.
Measurements obtained during hydrogel and silicone hydrogel contact lens (CL) wear and in the absence of CLs. The shadows of the violin graphs represent the data density, and the red diamonds indicate the mean values (*P 0.05, **P 0.001).
According to the Friedman test, statistically significant differences in NIBUT were observed among the three scenarios (P = 0.018). A statistically significant difference (P = 0.019) revealed a lower NIBUT with the silicone hydrogel CL (12.7 6.2 s) compared to no CL wear (18.5 9.8 s) [Figure 1B]. No significant differences were found between the hydrogel CL (13.8 6.9 s) and the no CL condition (P = 0.125), nor between the two CL materials (P = 0.384).
Significant differences in lipid layer thickness were found among the three scenarios (ANOVA P 0.001). Lipid layer thickness was lower while wearing the hydrogel CL compared to the silicone hydrogel CL (64.9 15.5 vs. 75.8 14.0; P 0.001) and the no CL condition (75.9 14.2; P = 0.001). No differences were found between not wearing CLs and wearing the silicone hydrogel CL (P = 0.976) [Figure 1C].
Finally, there were no statistically significant differences in the partial blink rate observed among the three scenarios (Friedman test P = 0.477) [Figure 1D].
DISCUSSION
The insertion of a CL onto the ocular surface splits the tear film, altering its optimal structure and increasing its evaporation.[1,2] Given that hydrogel and silicone hydrogel CLs are the most commonly fitted CLs,[23,24,25] this study aimed to evaluate the pre-lens tear film changes in the ocular surface induced by CL wear, comparing a hydrogel CL (omafilcon A) and a silicone hydrogel CL (stenfilcon A).
The results of the present study confirmed that wearing a CL increases tear film evaporation; however, the tear evaporation rate did not differ between the two CL materials tested in the present study. The results align with those reported by Thai et al,[21] who compared five CL materials (including omafilcon A) and found no significant differences among them. However, the results reported without CLs were lower in the study by Thai et al[21] than in the present study (39.05 19.03 g/m2/h vs. 69.9 41.3 g/m2/h, respectively). The differences observed might be due to the use of different instruments to measure the tear evaporation rate. Thai et al[21] used the Servo-Med EP-3 Evaporimeter, whereas we employed the Eye-VapoMeter in the present study. Another study using the Eye-VapoMeter also reported tear evaporation rate values in healthy individuals (range, 56.06 25.61 to 73.31 35.02 g/m2/h) that were similar to those observed in the present study.[26]
In the present study, a statistically significant decrease in NIBUT was observed with the silicone hydrogel CLs compared to no CL wear. Although no statistically significant differences were found between the hydrogel CLs and no CL wear, the differences may be considered clinically relevant, as NIBUT values were similar between the two CL materials. These findings align with other authors who reported decreased NIBUT values during the use of omafilcon A and stenfilcon A CLs compared to no CL wear.[27,28]
Lipid layer thickness was the only parameter that showed statistically significant differences between the two evaluated CLs. The lower value observed with the hydrogel CL compared to the silicone hydrogel CL and no CL wear was an unexpected finding. This discrepancy may be attributed to differences in the material composition (presence or absence of silicone in the polymer) or the hydration technology (Aquaform technology or PC Technology), both of which vary between the CLs used in this study. Designed to maintain hydration and wettability, these technologies can function differently, resulting in varied behaviors on the CL surface. As new technologies continue to emerge, independent evaluation of each material's performance is crucial. The results regarding NIBUT values suggest lower tear film stability during the use of silicone hydrogel CL, which could be due to a thinner tear film lipid layer. However, the difference in lipid layer thickness between no CL wear and silicone hydrogel CL wear was not statistically significant. This can be explained by the fact that the average lipid layer thickness values obtained in the present study were higher than those reported in other studies.[29,30] This can reflect a characteristic of our study sample, consisting of young and asymptomatic participants with a large range of CL wear frequency. Further studies are needed to understand this contradictory result. The interaction between the tear film and the silicone hydrogel CL seems similar to that of the conventional hydrogel CL used in this study, so the final decision on whether to fit one CL or the other could be based on other properties, such as oxygen permeability.
Regarding the partial blink rate, no differences were found with the use of CLs or between the CL materials evaluated in the present study. The same results were reported in previous studies that compared partial blinks with and without CLs.[15,31] These findings suggest that the hydrogel CL wear itself does not affect the area covered by the eyelids during blinking. Instead, the partial blink rate might be more influenced by the visual tasks performed during CL wear.[32]
The novelty of the present study, which makes it a well-controlled clinical experiment, lies in being the first to assess the tear evaporation rate to compare the tear film dynamics between a conventional and a silicone hydrogel CL in the same individuals in a randomized crossover and double-masked approach. However, this study has some limitations. First, clinical evaluation was performed after 30 minutes of CL wear to ensure lens stability. Hence, it may not be warranted to generalize the CL behavior observed in this study for a whole day of CL wear. It would be interesting to evaluate the tear film parameters and CL discomfort symptoms after longer hours of CL wear, as it is well known that CL discomfort increases throughout the day.[33,34] Second, tear film measurements were performed during the same visit to facilitate the volunteer's recruitment. Therefore, although measurements were performed after 30 minutes of CL wear for both materials without a long washout time, tear film measurements with the second CL could be minimally affected after using the first one. However, both CLs were fitted following a random order. Thus, this methodology helped to avoid biased results. Finally, only two specific CLs—one hydrogel (omafilcon A) and one silicone hydrogel (stenfilcon A)—were evaluated. Therefore, while this study provides interesting insights for CL practitioners, it seems promising to conduct further studies that include different CL materials under different environmental conditions[18,35] in order to objectively evaluate CL behavior based on tear evaporation rates and lipid layer thickness. Despite the above limitations, the present study indicates that it is necessary to consider all the properties of CLs when prescribing them. Silicone hydrogel CLs are excellent in terms of oxygen permeability, but some patients experience problems related to wettability, comfort, or vision. Thus, it might be recommended to routinely evaluate the tear evaporation rate and lipid layer thickness in clinical practice.
In summary, the insertion of a CL affects tear film properties in terms of evaporation and stability, but not blinking. However, different CL materials and hydration technologies induce different behaviors in the pre-lens tear film components, at least during short-term CL wear. Further studies are needed to assess whether these changes in tear film parameters persist after several hours of CL wear.
Financial Support and Sponsorship
This work was partially supported by the Ministry of Universities and European Social Fund under Grant number FPU19/01109; and Junta de Castilla y León and European Social Fund under Grant number EDU/556/2019. Funders had no role in the study.
Conflicts of Interest
None.
References
- Nichols JJ, King-Smith PE. Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry. Invest Ophthalmol Vis Sci. 2003;44:68–77. doi: 10.1167/iovs.02-0377. [DOI] [PubMed] [Google Scholar]
- Graham AD, Lin MC. The relationship of pre-corneal to pre-contact lens non-invasive tear breakup time. PLoS One. 2021;16:e0247877. doi: 10.1371/journal.pone.0247877. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Craig JP, Willcox MD, Argüeso P, Maissa C, Stahl U, Tomlinson A, et al ; members of TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: Report of the contact lens interactions with the tear film subcommittee Invest Ophthalmol Vis Sci. 2013;54:TFOS123–56. doi: 10.1167/iovs.13-13235. [DOI] [PubMed] [Google Scholar]
- Aragona P, Baudouin C, Benitez Del Castillo JM, Messmer E, Barabino S, Merayo-Lloves J, et al. The ocular microbiome and microbiota and their effects on ocular surface pathophysiology and disorders. Surv Ophthalmol. 2021;66:907–925. doi: 10.1016/j.survophthal.2021.03.010. [DOI] [PubMed] [Google Scholar]
- Fukui M, Yamada M, Akune Y, Shigeyasu C, Tsubota K. Fluorophotometric analysis of the ocular surface glycocalyx in soft contact lens wearers. Curr Eye Res. 2016;41:9–14. doi: 10.3109/02713683.2014.999948. [DOI] [PubMed] [Google Scholar]
- Pult H, Murphy PJ, Purslow C. A novel method to predict the dry eye symptoms in new contact lens wearers. Optom Vis Sci 2009;86:E1042–E1050. [DOI] [PubMed] [Google Scholar]
- Best N, Drury L, Wolffsohn JS. Predicting success with silicone-hydrogel contact lenses in new wearers. Cont Lens Anterior Eye. 2013;36:232–237. doi: 10.1016/j.clae.2013.02.013. [DOI] [PubMed] [Google Scholar]
- Glasson MJ, Stapleton F, Keay L, Sweeney D, Willcox MD. Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers. Invest Ophthalmol Vis Sci. 2003;44:5116–5124. doi: 10.1167/iovs.03-0685. [DOI] [PubMed] [Google Scholar]
- Santodomingo-Rubido J, Wolffsohn JS, Gilmartin B. Changes in ocular physiology, tear film characteristics, and symptomatology with 18 months silicone hydrogel contact lens wear. Optom Vis Sci. 2006;83:73–81. doi: 10.1097/01.opx.0000200681.23663.48. [DOI] [PubMed] [Google Scholar]
- King-Smith PE, Fink BA, Hill RM, Koelling KW, Tiffany JM. The thickness of the tear film. Curr Eye Res. 2004;29:357–368. doi: 10.1080/02713680490516099. [DOI] [PubMed] [Google Scholar]
- Talbott K, Xu A, Anderson DM, Seshaiyer P. Modelling the evaporation of a tear film over a contact lens. Math Med Biol. 2015;32:209–238. doi: 10.1093/imammb/dqu001. [DOI] [PubMed] [Google Scholar]
- Siddireddy JS, Vijay AK, Tan J, Willcox M. The eyelids and tear film in contact lens discomfort. Cont Lens Anterior Eye. 2018;41:144–153. doi: 10.1016/j.clae.2017.10.004. [DOI] [PubMed] [Google Scholar]
- Rohit A, Ehrmann K, Naduvilath T, Willcox M, Stapleton F. Validating a new device for measuring tear evaporation rates. Ophthalmic Physiol Opt. 2014;34:53–62. doi: 10.1111/opo.12096. [DOI] [PubMed] [Google Scholar]
- Yang SN, Tai YC, Sheedy JE, Kinoshita B, Lampa M, Kern JR. Comparative effect of lens care solutions on blink rate, ocular discomfort and visual performance. Ophthalmic Physiol Opt. 2012;32:412–420. doi: 10.1111/j.1475-1313.2012.00922.x. [DOI] [PubMed] [Google Scholar]
- Collins MJ, Iskander DR, Saunders A, Hook S, Anthony E, Gillon R. Blinking patterns and corneal staining. Eye Contact Lens. 2006;32:287–293. doi: 10.1097/01.icl.0000224551.58399.9a. [DOI] [PubMed] [Google Scholar]
- Efron N, Jones L, Bron AJ, Knop E, Arita R, Barabino S, et al. Members of the TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: Report of the contact lens interactions with the ocular surface and adnexa subcommittee. Invest Ophthalmol Vis Sci 2013; 54:TFOS98–TFOS122. [DOI] [PubMed] [Google Scholar]
- Jones L, Brennan NA, González-Méijome J, Lally J, Maldonado-Codina C, Schmidt TA, et al. Members of the TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: Report of the contact lens materials, design, and care subcommittee. Invest Ophthalmol Vis Sci 2013;54:TFOS37–TFOS70. [DOI] [PubMed] [Google Scholar]
- López-de la Rosa A, Martín-Montañez V, López-Miguel A, Fernández I, Calonge M, González-Méijome JM, et al. Ocular response to environmental variations in contact lens wearers. Ophthalmic Physiol Opt. 2017;37:60–70. doi: 10.1111/opo.12338. [DOI] [PubMed] [Google Scholar]
- Glasson MJ, Stapleton F, Keay L, Willcox MD. The effect of short term contact lens wear on the tear film and ocular surface characteristics of tolerant and intolerant wearers. Cont Lens Anterior Eye. 2006;29:41–47. doi: 10.1016/j.clae.2005.12.006. [DOI] [PubMed] [Google Scholar]
- Chalmers RL, Begley CG, Moody K, Hickson-Curran SB. Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and opinion of contact lens performance. Optom Vis Sci. 2012;89:1435–1442. doi: 10.1097/OPX.0b013e318269c90d. [DOI] [PubMed] [Google Scholar]
- Thai LC, Tomlinson A, Doane MG. Effect of contact lens materials on tear physiology. Optom Vis Sci. 2004;81:194–204. doi: 10.1097/00006324-200403000-00012. [DOI] [PubMed] [Google Scholar]
- Hommel G. A stagewise rejective multiple test procedure based on a modified Bonferroni test. Biometrika. 1988;75:383–386. [Google Scholar]
- Morgan PB, Woods CA, Tranoudis IG, Helland M. International contact lens prescribing in 2014. Contact Lens Spectr. 2015;30:28–33. [Google Scholar]
- Morgan PB, Efron N. Quarter of a century of contact lens prescribing trends in the United Kingdom (1996–2020) Cont Lens Anterior Eye. 2022;45:101446. doi: 10.1016/j.clae.2021.101446. [DOI] [PubMed] [Google Scholar]
- Morgan PB, Efron N. Global contact lens prescribing 2000-2020. Clin Exp Optom. 2022;105:298–312. doi: 10.1080/08164622.2022.2033604. [DOI] [PubMed] [Google Scholar]
- Arroyo CA, Byambajav M, Fernández I, Martin E, González-García MJ, López-Miguel A, et al. Diurnal variation on tear stability and correlation with tear cytokine concentration. Cont Lens Anterior Eye. 2022;45:101705. doi: 10.1016/j.clae.2022.101705. [DOI] [PubMed] [Google Scholar]
- Llorens-Quintana C, Mousavi M, Szczesna-Iskander D, Iskander DR. Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy. Cont Lens Anterior Eye. 2018;41:18–22. doi: 10.1016/j.clae.2017.08.005. [DOI] [PubMed] [Google Scholar]
- Montani G, Martino M. Tear film characteristics during wear of daily disposable contact lenses. Clin Ophthalmol. 2020;14:1521–1531. doi: 10.2147/OPTH.S242422. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tichenor AA, Cox SM, Ziemanski JF, Ngo W, Karpecki PM, Nichols KK, et al. Effect of the Bruder moist heat eye compress on contact lens discomfort in contact lens wearers: An open-label randomized clinical trial. Cont Lens Anterior Eye. 2019;42:625–632. doi: 10.1016/j.clae.2019.09.005. [DOI] [PubMed] [Google Scholar]
- Bai Y, Ngo W, Gu B, Zhang Y, Nichols JJ. An imaging system integrating optical coherence tomography and interferometry for in vivo measurement of the thickness and dynamics of the tear film. Biomed Eng Online. 2018;17:164. doi: 10.1186/s12938-018-0597-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vidal-Rohr M, Wolffsohn JS, Davies LN, Cerviño A. Effect of contact lens surface properties on comfort, tear stability and ocular physiology. Cont Lens Anterior Eye. 2018;41:117–121. doi: 10.1016/j.clae.2017.09.009. [DOI] [PubMed] [Google Scholar]
- Jansen ME, Begley CG, Himebaugh NH, Port NL. Effect of contact lens wear and a near task on tear film break-up. Optom Vis Sci. 2010;87:350–357. doi: 10.1097/OPX.0b013e3181d951df. [DOI] [PubMed] [Google Scholar]
- Woods CA, Bentley SA, Fonn D. Temporal changes in contact lens comfort over a day of wear. Ophthalmic Physiol Opt. 2016;36:643–648. doi: 10.1111/opo.12318. [DOI] [PubMed] [Google Scholar]
- Novo-Diez A, Arroyo-Del Arroyo C, Blanco-Vázquez M, Fernández I, López-Miguel A, González-García MJ. Usefulness of a global rating change scale for contact lens discomfort evaluation. Cont Lens Anterior Eye. 2021;44:101467. doi: 10.1016/j.clae.2021.101467. [DOI] [PubMed] [Google Scholar]
- Fernández I, López-Miguel A, Martín-Montañez V, Enríquez-de-Salamanca A, Calonge M, González-Méijome JM, et al. Inflammatory status predicts contact lens discomfort under adverse environmental conditions. Ocul Surf. 2020;18:829–840. doi: 10.1016/j.jtos.2020.07.015. [DOI] [PubMed] [Google Scholar]

