Abstract
Purpose
There are two main methods of femoral graft fixation during anterior cruciate ligament reconstruction (ACLR): cortical button (CB) and interference screws (IS). Each fixation yields its own unique outcomes; however, there is yet to be an established gold standard. We seek to compare femoral CB to IS fixation in ACLR using all soft‐tissue, autograft hamstring grafts. We hypothesise that there will be no significant differences between the two methods.
Methods
A systematic review and meta‐analysis were conducted following the 2020 PRISMA guidelines. PubMed, Cochrane, Embase, Web of Science and Scopus were screened for potential randomised studies. The studies must have utilised both the semitendinosus and gracilis, and utilised either metallic or bioabsorbable IS, or fixed or adjustable loop CB fixation on femoral fixation. All studies in both groups must have used interference screws on the tibial side. The 2‐year follow‐up analysed KT‐1000 side‐to‐side differences, while the 5–10 year follow‐up compared Lysholm and Tegner scores.
Results
A total of 12 randomised studies were included in the final systematic review, providing an evaluation of 583 distinct patients. Two of the studies were excluded from the meta‐analysis, due to not providing pre‐ and post‐operative means and standard deviations. At 2‐year and 5‐10 year follow‐ups, the mean ages were 30.5 ± 8.7 and 30.2 ± 8.1, respectively. Analysis of the 2‐year follow‐up favour of CB (p = 0.01) in regards to the reduction in KT‐1000 side‐to‐side differences. Analysis of the 5–10 year follow‐up revealed favour of CB in regards to the Lysholm Score (p < 0.01), and the Tegner Score (p < 0.01).
Conclusions
At 2‐years postoperatively, femoral fixation utilising cortical buttons portrayed less knee laxity than interference screws. At the 5–10 year follow‐up, cortical buttons yielded more sports and work‐related activity, less pain, and overall greater function than did the interference screws.
Level of Evidence
Level II.
Keywords: ACL repair, cortical button, femoral fixation, hamstring tendon graft, interference screw
Abbreviations
- ACLR
anterior cruciate ligament reconstruction
- CB
cortical button
- HT
hamstring tendon
- IKDC
International Knee Committee Documentation
- IS
interference screw
INTRODUCTION
Anterior cruciate ligament reconstruction (ACLR) is predominantly performed to address knee instability after complete rupture of the anterior cruciate ligament (ACL) [3]. This procedure aims to restore structural integrity and knee kinematics through the use of a graft in place of the disrupted native ACL [1]. Although bone‐patellar tendon‐bone (BPTB) is considered the ‘gold’ standard of care, hamstring tendon (HT) and quadriceps tendon (QT) autograft‐based reconstruction have evidence supporting their status as valid alternatives [6, 11].
Regardless of the graft utilised, there are two commonly utilised methods of fixation for the graft to be secured within the femoral tunnel. These fixation options are interference screws (IS) and cortical button (CB) suspensory fixation. Interference screws, commonly composed of either metal, Polyether Ether Ketone (PEEK), or bioabsorbable materials, function to provide compressive aperture fixation within the femoral bone tunnel [5, 26]. These screws serve to compress and secure the graft against the bone tunnel wall, allowing for time zero fixation [22]. Benefits of IS fixation during ACLR include reduced tunnel widening, graft‐tunnel motion, and graft creep [17]. In comparison, CB devices are comprised of a metallic button and a looped construct that allows for the graft to be fixated at the far cortex of the femur through a suspensory mechanism [16]. A benefit to this form of fixation is circumferential contact of the graft can be obtained by the graft within the femoral tunnel for increased biologic healing potential [20].
In this systematic review and meta‐analysis, we compare the outcomes of femoral fixation between IS to CB suspensory devices in ACLR patients receiving HT autografts. It is hypothesised that no significant differences between IS and CB fixation for patients undergoing ACLR with hamstring autografts would be observed.
METHODS
A systematic review and meta‐analysis were conducted following the 2020 Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) guidelines [21]. We sought to compare the use of IS to CB fixation on the femoral aspect during ACLR, using all soft‐tissue, autograft hamstring tendon grafts. To investigate postoperative outcomes, we compared KT‐1000 side‐to‐side differences, Tegner scores, and Lysholm scores between the two proximal fixation groups. KT‐1000 side‐to‐side differences were assessed at a 2‐year follow up, while Tegner and Lysholm scores were assessed at 5–10 years postoperatively.
Search procedure
On 15 August 2024, five online databases (Cochrane, Embase, PubMed, Scopus and Web of Science) were searched using the following search string: (‘Cortical Fixation’ OR ‘Suspensory Fixation’ OR ‘Fixed loop’ OR ‘Interference screws’ OR ‘Arthroscopic technique’ OR ‘Screw fixation’) AND (‘ACL Reconstruction’ OR ‘Anterior Cruciate Ligament Reconstruction’ OR ‘ACLR’ OR ‘Arthroscopic anterior cruciate ligament reconstruction’ or ‘Bone‐tendon‐bone’ OR ‘Bone‐hamstring‐bone’) AND (‘Semitendinosus’ OR ‘Hamstring’) AND (‘Randomised Controlled Trial’ OR ‘RCT’ OR ‘Clinical Trial’). Key terms were identified using the Medical Subject Headings (MeSH) tool.
Inclusion and exclusion criteria
Included studies must have met all of the following criteria: randomised, conducted ACLR using a quadrupled single‐bundle hamstring tendon autograft composed of both the semitendinosus and gracilis tendons, utilised either metallic or bioabsorbable interference screws (IS group) or fixed or adjustable loop cortical button (CB group) fixation on the femoral aspect of the ACLR procedure, used interference screws on the tibial aspect in order to control for confounding variables, published after 2010. Studies were excluded if allograft tendon grafts or the all‐inside ACLR approach were used. All cross‐sectional, cohort, case control, case series, case studies, cadaveric, and nonrandomized studies were excluded.
Study selection
The search string yielded 309 total articles across the five databases. The results retrieved from each database using the search string were imported into Rayyan.ai. Automated detection of duplicates was utilised to assess for any potential duplicates; however, the detected duplicates were reviewed by two independent authors to confirm its findings. Duplicates were then excluded, and the remaining studies were subjected to evaluation by two independent authors for determination of inclusion and exclusion. Any dissent was resolved by a third author.
Following deletion of duplicates, 163 articles remained. The abstracts and titles of the remaining studies were screened and 126 studies were eliminated in the process. Thirty‐seven records were then sought for retrieval and successfully retrieved. Following retrieval, the 37 studies underwent a thorough, full‐text examination. Twenty‐five studies were eliminated during full‐text review, due to 13 having insufficient data, three not including both semitendinosus and gracilis tendon grafts, three using double‐bundle ACLR, two not using interference screws on the tibial attachment, two using the all‐inside approach, and two having a follow‐up time outside of our study.
Data extraction
For the included studies, all necessary data was extracted onto a Microsoft Excel sheet. All data was collected independently by four reviewers. The titles, authors, year of publication, country, study design, recruitment period, interventions, sample size of each intervention, ages, inclusion criteria, outcomes collected and main findings were collected from each study. Additionally, the following variables were extracted in mean and standard deviation (SD) format: 2‐year KT‐1000 scores, 5–10 year Tegner scores, 5–10 year Lysholm scores. If a study included additional groups that were not of interest to our review, only groups that met our inclusion criteria were included in this review and analysis.
Statistical analysis
All statistical analysis was conducted on IBM Statistical Package for Social Sciences (SPSS) version 29. A measure of effect size regarding KT‐1000 side‐to‐side differences, Tegner scores, and Lysholm score was analysed utilising a random effects model. A subgroup analysis was conducted in order to assess for significant differences between the two groups. A Δ Hedge's g value ≥ 0.80 was used as a cutoff to assess for a clinically significant difference, and a p‐value < 0.05 was used to assess for statistical significance, using 95% confidence intervals.
Heterogeneity was analysed using the I 2, H 2, and τ 2 values from the measure of effect size using the KT‐1000 side‐to‐side differences, Tegner score, and Lysholm scores using a random effects model.
Risk of bias and certainty of evidence assessment
Bias in the articles was assessed independently by two authors. Because all of the articles included were RCTs, they were subjected to evaluation according to the Risk of Bias‐2 (RoB‐2) tool. To assess for quality, all included studies have been also subjected to a modified version of the Grading of Recommendations Assessment, Development and Evaluation (GRADE).
RESULTS
Search results
A total of 12 randomised controlled trials (RCT) were included in the final systematic review [2, 4, 7, 10, 13, 14, 19, 23, 27, 29, 30, 31]. A PRISMA flow chart of the selection process is portrayed in Figure 1. Two studies conducted by Stener et al. [27] and Djordjević et al. [7] were included in the systematic review, but were excluded from the meta‐analysis, due to not providing pre‐ and post‐operative means and standard deviations regarding their data. An RCT conducted by Roger et al. was not included in either the systematic review or the meta‐analysis, due to using femoral pin transfixation, rather than a cortical button [24].
Figure 1.

PRISMA flowchart of article selection.
Group demographics
The 10 studies included in the meta‐analysis yielded an evaluation from follow‐ups from 537 distinct patients. At 2‐year and 5–10 year follow‐ups, the mean ages were 30.5 ± 8.7 and 30.2 ± 8.1, respectively. Baseline KT‐1000, Lysholm scores, and Tegner scores are presented in Table 1.
Table 1.
Baseline mean ± SD regarding KT‐1000 side‐to‐side differences, Lysholm scores, and Tegner scores between the two groups.
| Measure | IS | CB |
|---|---|---|
| Preoperative | ||
| KT‐1000 side‐to‐side difference (mean ± SD) | 4.2 ± 2.7 | 6.9 ± 2.32 |
| Lysholm (mean ± SD) | 64.7 ± 16.7 | 60.0 ± 12.0 |
| Tegner score (mean ± SD) | 4.0 ± 1.1 | 3.0 ± 1.3 |
Abbreviation: SD, standard deviation.
Effects of intervention
Analysis of the 2‐year follow‐up portrayed a significant difference in favour of CB (Δ Hedge's g = 3.16, p = 0.01, Figure 2) regarding the reduction in KT‐1000 side‐to‐side differences. Analysis of the 5–10 year follow‐up revealed a significant difference in favour of CB regarding the Lysholm Score (Δ Hedge's g = 1.08, p < 0.01, Figure 3), and the Tegner Score (Δ Hedge's g = 1.78, p < 0.01, Figure 4). The results have been summarised in Table 2.
Figure 2.

Comparison of KT‐1000 side‐to‐side differences at 2‐year follow‐up.
Figure 3.

Comparison of Lysholm scores at 5–10 year follow‐up.
Figure 4.

Comparison of Tegner scores at 5–10 year follow up.
Table 2.
Summary of the analysed data between IS and CB.
| Variable | Group | Mean ± SD | Hedge's g | Δ Hedge's g | p‐Value |
|---|---|---|---|---|---|
| 2‐year follow‐up | |||||
| KT‐1000 side‐to‐side difference | IS | 2.0 ± 2.4 | −0.85 | 3.16 | 0.01* |
| CB | 1.4 ± 1.8 | −3.47 | |||
| 5‐10 year follow‐up | |||||
| Lysholm | IS | 89.4 ± 15.2 | 1.62 | 1.08 | <0.01* |
| CB | 89.0 ± 9.0 | 2.70 | |||
| Tegner | IS | 5.6 ± 1.5 | 1.23 | 1.78 | <0.01* |
| CB | 7.7 ± 1.8 | 3.01 | |||
Note: The use of *signifies statistical significance. The use of red font signifies clinical significance.
Abbreviations: CB, cortical button; IS, interference screws; SD, standard deviation.
Risk of bias and certainty of evidence assessment
A Grading of Recommendations Assessment, Development and Evaluation (GRADE) analysis and certainty of evidence of the included 12 studies was performed independently by two authors based on Cochrane guidelines [25]. Out of those 12 studies, three studies were assessed as low quality of evidence, and the remaining nine studies were of moderate quality of evidence. Each study was critically appraised, and criticism notes are provided in Table 3.
Table 3.
Summary of GRADE analysis of the included studies based on Cochrane guidelines.
| Author, year | Study design | Risk of bias | Inconsistency | Indirectness | Imprecision | Publication bias | Final grade | Criticism |
|---|---|---|---|---|---|---|---|---|
| Suomalainen et al. [30], 2012 | RCT | Serious | Serious | Serious | Very serious | Not likely | Low | While the study was well‐designed for its methodology, there was significant data loss at follow‐up, ranging from 3% to 30% of patients in various groups. As well as there are about 10% of patients who experienced graft failure, resulting in loss of that data, which was not part of the statistics, representing a better design of statistics, but loss of data can impact the power of the data. |
| Ranjan et al. [23], 2018 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | A well‐designed study reported all the outcomes mentioned in the design, with minimal patient loss to follow‐up. Outcomes, patient loss to follow up were appropriately accounted for, and statistics were reported for all the outcomes measured in a respective fashion. |
| Mo et al. [19], 2024 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | Overall study provides excellent data. A well‐organised methodology, but concerns arise when a patient with a concomitant procedure was decided to be included for meniscus tears, could be a confounding variable in reported outcomes. All patients were accounted for, and outcomes were reported appropriately. |
| Suomalainen et al. [31], 2011 | RCT | Not serious | Serious | Serious | Serious | Likely | Low | The study provides great insights in well‐organised outcomes as mentioned in the methods. The only concern that arises is that the included sample size was less than that of the power initially calculated by the statistician, and about 20% of the patients were lost to follow‐up. |
| Stener et al. [27], 2010 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | Well‐designed study with no deviation from any measurement or intended outcomes. The only drawback power analysis was not performed for the measurement required sample size for the study. |
| Arama et al. [2], 2015 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | Structured clinical study with appropriate randomisation and clinical assessments performed and reported. |
| Järvelä et al. [13], 2017 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | Well‐organised study with randomisation, measurement, and reporting of pre‐ & post‐intervention data. Power analysis for sampling was not reported in the methods, but all patients lost at follow‐up were accounted for. |
| Carulli et al. [4], 2017 | RCT | Not serious | Serious | Serious | Not serious | Likely | Low | The study provides insights into the use of fixation techniques, but the problem there stems from the randomisation process not being clearly described, and outcomes are not completely reported at 6 months and 1 year, as mentioned in the methods. |
| Karikis et al. [14], 2017 | RCT | Not serious | Serious | Serious | Serious | Not likely | Moderate | The study design lacks clarity in the randomisation process as well, and no data is reported for 2‐year outcomes. There is a loss of patient follow at 10‐15% in subgroups. Concerns arise with the possibility of a lack of power for the study. |
| Sun et al. [29], 2011 | RCT | Not serios | Serious | Serious | Not serious | Not likely | Moderate | The study is well‐designed with randomisation and reporting of outcomes at the mentioned intervals. |
| Djordjević et al. [7], 2021 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | The study was well designed, with proper randomisation, and all the outcomes mentioned were measured and reported. |
| Gupta et al. [10], 2017 | RCT | Not serious | Serious | Serious | Not serious | Not likely | Moderate | The study was well designed, with proper randomisation, and all the outcomes mentioned were measured and reported. Slight concerns with the single randomisation process. |
Abbreviations: GRADE, Grading of Recommendations Assessment, Development and Evaluation; RCT, randomised controlled trial.
The same two authors performed a risk of bias analysis based on the Cochrane Risk of Bias Handbook [28]. RoB‐2 guidelines were followed for the 12 included randomised controlled trials for each domain of the RoB‐2 analysis. 8 studies were evaluated as low risk of bias for the methodology and reporting characteristics of the study. While three studies were rated with some concerns, and one study was considered high risk. Each domain that was evaluated for the included studies is represented in Figure 5, along with a summary plot as Figure 6 using the RobVis tool [18].
Figure 5.

Traffic light plot of the RoB‐2 analysis of the included studies.
Figure 6.

Summary plot of the RoB‐2 analysis of the included studies.
Summary of findings
Table 4.
Summary of findings regarding the 12 studies included in our review.
| Title | Study ID (author, year) | Country | Study design | Recruitment period | Intervention | Number of patients | Age | Inclusion criteria | Outcomes collected | Main findings |
|---|---|---|---|---|---|---|---|---|---|---|
| Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction | Suomalainen, Piia; 2012 | Finland | RCT | 2003–2005 | Double bundle bioabsorbable ACL reconstruction vs. single bundle bioabsorbable ACL reconstruction vs. single bundle metallic ACL reconstruction |
Double bundle: 20 Single bundle Bioabsorbable: 21 Single bundle Metallic: 24 |
Double Bundle: 34 ± 10 Single Bundle Bioabsorbable: 30 ± 8 Single Bundle Metallic: 33 ± 10 |
Primary ACL reconstruction with closed growth plates and lack of ligamentous injury to the contralateral knee | Pivot shift test with KT‐1000, IKDC, Lysholm Knee scores at the 5 year follow up | There are no statistically significant changes between the different surgery modalities in any of the three tests at the 5 year mark, but all surgeries showed significant improvement over pre‐surgery performance |
| In vivo comparison of a fixed loop (EndoButton CL) with an adjustable loop (TightRope RT) device for femoral fixation of the graft in ACL reconstruction: A prospective randomised study and a literature review | Ranjan, Rahul; 2018 | India | RCT | November 2012–August 2014 | Fixed loop endobutton vs. adjustable loop tightrope fixation devices |
EndoButton: 52 Tightrope: 50 |
EndoButton: 28.7 ± 9.45 Tightrope: 30.4 ± 7.9 |
Clinical and radiological evidence of an ACL tear, ages 18–50, normal contralateral knee | IKCD, Lysholm, and ATT scores at 6 months and 2 years | Both procedures saw significant improvements from baseline; however they did not show significant differences in outcomes when comparing Endbutton to Tightrope |
| ACL reconstruction using quadrupled semitendinosus versus double‐stranded semitendinosus and gracilis autograft 2‐year results from a prospective randomised controlled study | Mo, Ingunn Fleten; 2024 | Norway | RCT | April 2014–December 2019 | All‐inside semitendinosus vs. traditional hamstring operation |
All‐inside: 48 Traditional: 49 |
All‐inside: 34 ± 9.5 Traditional: 34 ± 10.1 |
Patient's age greater than 16, skeletal maturity, and no previous injury to same or contralateral knee | IKDC, KOOS, and TAS scores at baseline and 24 months | There are no significant differences in clinical outcomes between the 2 groups at the 2 year mark |
| Bioabsorbable versus titanium screws in anterior cruciate ligament reconstruction using hamstring autograft a prospective, blinded, randomised controlled trial with 5‐year follow‐up | Arama, Yuval; 2015 | Australia | RCT | June 2002–October 2003 | PLLA‐HA vs. Titanium |
PLLA‐HA: 20 Titanium: 20 |
PLLA‐HA: 33 ± 7.2 Titanium: 29 ± 6.5 |
Patients with a primary anterior cruciate ligament reconstruction with 4‐stranded hamstring graft and written consent | IKCD, KT‐1000, single leg hop test at 2 and 5 years | There are no clinical differences in outcomes between the 2 categories at the 2 and 5 year marks |
| Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction a prospective randomised study with 10‐year results | Jarvela, Sally; 2017 | Finland | RCT | 2003–2005 | Double bundle bioabsorbable ACL reconstruction vs. single bundle bioabsorbable ACL reconstruction vs. single bundle metallic ACL reconstruction |
Double bundle: 24 Single bundle Bioabsorbable: 23 Single bundle Metallic: 23 |
Double bundle: 34 ± 10 Single Bundle Bioabsorbable: 30 ± 8 Single Bundle Metallic: 33 ± 10 |
Primary ACL reconstruction with closed growth plates and lack of ligamentous injury to the contralateral knee | Pivot shift test with KT‐1000, IKDC, Lysholm Knee scores at the 10 year follow up | There are no statistically significant changes between the different surgery modalities in any of the three tests at the 10 year mark, but all surgeries showed significant improvement over pre‐surgery performance |
| Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods | Carulli, Christian; 2016 | Italy | RCT | 2009 and 2012 | BioIntrafix vs. BioRCI tibial screw and titanium staples |
BioIntrafix: 45 BioRCI: 45 |
BioIntrafix: 31.0 (16–42) BioRCI: 31.8 (18–44) |
Patients with unilateral isolated ACL ruptures who were candidates for an arthroscopically assisted reconstruction | KOOS, IKDC, and KT‐2000 scores at baseline, 6, 12, and 24 months | There are no significant clinical or radiological differences between BioIntrafix and BioRCI |
| Radiographic tibial tunnel assessment after anterior cruciate ligament reconstruction using hamstring tendon autografts and biocomposite screws: a prospective study with 5‐year follow‐up | Karikis, Ioannis; 2017 | Sweden | RCT | March 2008–September 2009 | Single bundle | Single bundle: 51 | Single bundle: 28 ± 8.5 | Patients 18 years or older with a unilateral ACL injury | KT‐1000, pivot‐shift test, ROM, Lysholm knee scoring scale, and Tegner activity preoperatively and 5 years later | This study group showed improved clinical outcomes compared to their preoperative results |
| Arthroscopic reconstruction of the anterior cruciate ligament with hamstring tendon autograft and fresh‐frozen allograft: A prospective, randomised controlled study | Sun, Kang; 2011 | China | RCT | 2000–2004 | Hamstring tendon autograft vs. hamstring tendon allograft |
Autograft: 91 Allograft: 95 |
Autograft: 29.6 ± 6.9 Allograft: 31.2 ± 8.3 |
Patients with no previous injury of surgery to the affected knee, no multiple ligamentous injuries, no malalignment, and ability to complete the study protocol | Lachman test, Anterior Drawer test, pivot shift test, varus and valgus stress test, KT‐2000, IKDC, Daniel 1‐legged hop test, Harner vertical jump test, ROM testing with an average follow up time of 7.8 years | There are no significant differences in the clinical outcomes between autograft and allograft patients, except for Allografts having a shorter operation time |
| Outcome of hamstring autograft with preserved insertions compared with free hamstring autograft in anterior cruciate ligament surgery at 2‐year follow‐up | Gupta, Ravi; 2017 | India | RCT | April 2012–April 2014 | Hamstring tendon autograft with preserved insertions vs. free hamstring tendon autograft |
Insertions: 55 Free Hamstring: 55 |
Insertions: 27.0 ± 7.5 Free Hamstring: 27.2 ± 5.7 |
Patients who are adult professional athletes with an ACL injury greater than 3 weeks old without any signs of knee inflation | Lachman test, Anterior Drawer test, Pivot Shift test, KT‐1000 test, Cinncinati knee score, Tegner activities score were assessed preoperatively, 3 months, 6 months, 12 months, and 24 months minimum | Hamstring autografts with preserved insertions had statistically better superior anterior stability, improved functional outcomes, and a closer return to pre‐injury sporting activity, however, no clinically significant difference was proven |
| Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction: randomised clinical and magnetic resonance imaging study with 2‐year follow‐up | Suomalainen, Pia; 2011 | Finland | RCT |
March 2003– February 2008 |
Single‐bundle technique with aperture interference screw fixation vs. double‐bundle technique with aperture interference screw fixation |
Single Bundle: 60 Double Bundle: 61 |
Single Bundle: 32 ± 10 Double Bundle: 32 ± 10 |
Patients with a primary ACL reconstruction, closed growth plates, and absence of ligament injury to the opposite knee | Clinical and MRI evaluation, KT‐1000, IKCD, and Lysholm knee score | The revision rate was significantly lower in patients who received double bundle technique than those who received single bundle |
| Application of two types of suspensory fixation in reconstruction of anterior cruciate ligament with a semitendinosus‐gracilis graft – A randomised prospective study | Djordjević, Dušan; 2021 | Serbia | RCT | January 2015–December 2017 | Femoral tunnel graft fixation with an adjustable length loop implant vs. Fixed length loop implant |
Adjustable: 30 Fixed: 30 |
Adjustable: 26.87 ± 6.388 Fixed: 27.87 ± 6.902 |
Patients with a unilateral lesion of the ACL less than 10 months prior to reconstruction, with or without a minor lesion of the medial or lateral meniscus, without arthritic changes and neuromuscular diseases; with 1 A femoral tunnel position, with 4B tibial tunnel position; with a willingness to participate in the study and to adhere to the rules for clinical and functional evaluation and for rehabilitation | KT‐1000, Lysholm score, IKDC‐2000, Lachman test, Pivot‐shift test | The functional results of both the fixed and adjustable implants were the same |
| A long‐term, prospective, randomised study comparing biodegradable and metal interference screws in anterior cruciate ligament reconstruction surgery: radiographic results and clinical outcome | Stener, Sven; 2010 | Sweden | RCT | January 1999–March 2000 |
Poly‐l‐lactide acid (PLLA) Screw Fixation vs. Metal Interference Screw fixation |
PLLA: 33 Metal: 31 |
PLLA: 26 (16‐38) Metal: 27 (16‐46) |
Unilateral ACL rupture verified clinically by a positive Lachman test and a positive pivot‐shift test or through a previous diagnostic arthroscopy | KT‐1000, Lysholm score, Tenger level, single‐leg hop test | There were significantly larger bone tunnels on the femoral side with the PLLA group compared to the metal group |
Note: Ages have been expressed as mean ± SD, or mean (range).
Abbreviations: ATT, anterior tibial translation; IKDC, International Knee Documentation Committee; KOOS, Knee Injury and Osteoarthritis Outcome score; KT‐1000, medical device that accesses knee stability; PLLA‐HA, poly‐l‐lactic acid‐hyaluronic acid; RCT, randomised controlled trial; TAS, Tegner Activity Scale.
DISCUSSION
The results of this review found that the utilisation of CB fixation of autograft HT ACLR on the femoral aspect yielded greater reduction in KT‐1000 side‐to‐side differences at 2‐years postoperatively. Additionally, significant improvements in Lysholm and Tegner scores at 5–10 year follow‐up were found in the CB cohort compared to the IS group. HT autografts are a commonly utilised graft that has fallen in and out of favour over the past 30 years [8, 15]. Despite their increased use, there is conflicting evidence about the optimal form of femoral fixation for these grafts.
In 2021, a systematic review and meta‐analysis was conducted by Yan et al, comparing three femoral fixation methods for HT autografts: IS, CB and cortical bone pins [35]. Their results found no statistically significant differences in outcomes between CB and IS. This discrepancy in the findings may be due to several factors. The main factor being that the previously published review only included two head‐to‐head studies to compare the two fixation methods, yielding a smaller, and possibly less generalisable sample size. Additionally, for these two fixation methods, the review had a follow‐up of approximately 2–3 years, and compared IKDC scores, rather than KT‐1000 side‐to‐side differences, Lysholm, or Tegner scores. Outside of the small sample size making it difficult to extrapolate the data more broadly, one of the two studies included was non‐randomised, further complicating the validity of the data. As such, the present meta‐analysis pooled data from ten studies, which has resulted in a greater sample size.
One possible explanation of our results pertains to the circumferential healing potential of the grafts within the femoral tunnel with CB suspensory fixation. CB fixation provides significantly higher yield load and ultimate failure load than IS [33]. The higher yield load observed in CB may result in less deformation in the structural integrity of the ACLR, potentially allowing for the fixation to work as intended for a longer period of time. Similarly, the higher ultimate failure load may reduce the need for ACLR revisions, which are known to reduce functional outcomes and patient satisfaction, while increasing the risk of osteoarthritis of the knee [12]. On the contrary, IS fixation compresses both the device and the graft, leading to possible deformation of the fixation device, while causing biomechanical compromise of the fixated grafts, as observed in an in vitro study conducted by Teng et al. [32].
Comparing CB to IS femoral fixation in ACLR with all soft‐tissue HT autografts, CB provided greater improvements in knee stability at 2‐years, and superior knee function with increased levels of activity at 5–10 years postoperation. However, due to the significant amount of heterogeneity observed in our analysis, surgeons must use their own discretion regarding which femoral fixation method is most appropriate for each individual patient. The results of our review promote the necessity of further, large‐scale RCTs, directly comparing CB to IS while assessing for the following outcomes: KT‐1000 side‐to‐side differences, International Knee Documentation (IKDC) scores, Lysholm scores, Tegner scores, VAS scores, pivot shift tests, retear rates and revision rates.
Limitations
According to the RoB‐2 analysis, one included study was of high concern for bias, three studies were of moderate concern, and eight studies were of low concern, with bias arising from randomisation processes, missing outcome data, and the available reported results. The GRADE analysis conducted on each of the included studies portrayed three studies to be of low quality of evidence, with the remaining nine studies yielding moderate qualities of evidence.
Regarding the design of our review, there are some limitations. Not all of the RCTs we included and analysed were directly comparing CB to IS. If an RCT was comparing one of the interventions of interest to another intervention that was not of interest, we collected and analysed the data only regarding our fixation method of interest. Additionally, our review analyzes different outcomes at different timelines, with KT‐1000 side‐to‐side differences being assessed at 2‐year follow‐up, while Lysholm and Tegner scores were assessed at 5–10 year follow‐up. Generalisability to other age groups may also pose a limitation to our review, as the mean ages at 2‐year and 5–10 year follow‐ups were 30.5 ± 8.7 and 30.2 ± 8.1, respectively. Moreover, our review did not compare revision and complicate rates for each intervention, largely due to unavailability of data in each included study. Importantly, this review focused exclusively on femoral fixation methods and did not compare tibial fixation techniques, which may also influence overall ACLR outcomes. Furthermore, we pooled data regarding fixed and adjustable loops (CB group) as well as biocomposite and metallic screws (IS group), which may have resulted in confounding by fixation type. However, previously published reviews have shown no significant differences between the mentioned subgroups [9, 34].
Lastly, the degree of heterogeneity of our review is significant in regards to the outcomes KT‐1000 (I 2 = 0.99) Lysholm scores (I 2 = 0.76) and Tegner scores (I 2 = 0.97). This may be due to our review including RCTs that were not directly head‐to‐head comparisons between CB and IS. Additionally, included studies may have differed in regards to surgeon experience, and post‐operation rehabilitation techniques.
CONCLUSION
Compared to IS fixation, CB fixation of HT autografts on the femoral aspect of ACLR may yield more symmetric knee laxity at 2‐years postoperatively, and greater functionality and activity at the 5–10 year postoperative follow‐up.
AUTHOR CONTRIBUTIONS
Jonathan Elias conceived of the presented idea. Jonathan Elias, Mitchell Kaplan, and MB selected studies. Mitchell Kaplan, Michael Bickford, Thomas Oliver, and Kunal Shah extracted data from the studies included. Jonathan Elias completed the statistics. Kunal Shah and Thomas Oliver completed the GRADE and bias assessment for each included study. Jonathan Elias, Mitchell Kaplan, Michael Bickford, Thomas Oliver, Kunal Shah, Elizabeth Ford, and Sean McMillan participated in the write‐up of the manuscript. Elizabeth Ford and Sean McMillan provided areas for improvement of the study concept and provided their input in their respective areas of expertise. All authors have reviewed and endorsed the final manuscript.
CONFLICT OF INTEREST STATEMENT
The authors declare no conflicts of interest.
ETHICS STATEMENT
The review was not registered with an institutional review board, as there was no contact with human subjects or access to personal information.
ACKNOWLEDGEMENTS
We did not receive any source of funding or support for the review.
Elias J, Kaplan M, Bickford M, Oliver T, Shah K, Ford E, et al. Superior long‐term stability and function associated with femoral cortical button versus interference screw fixation in ACL reconstruction: a systematic review and meta‐analysis. J Exp Orthop. 2025;12:e70439. 10.1002/jeo2.70439
DATA AVAILABILITY STATEMENT
The data extracted from each study is publicly available at each study's respective journal.
REFERENCES
- 1. Albishi W, Baltow B, Albusayes N, Sayed AA, Alrabai HM. Hamstring autograft utilization in reconstructing anterior cruciate ligament: Review of harvesting techniques, graft preparation, and different fixation methods. World J Orthop. 2022;13(10):876–890. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Arama Y, Salmon LJ, Sri‐Ram K, Linklater J, Roe JP, Pinczewski LA. Bioabsorbable versus titanium screws in anterior cruciate ligament reconstruction using hamstring autograft: a prospective, blinded, randomized controlled trial with 5‐year follow‐up. Am J Sports Med. 2015;43(8):1893–1901. [DOI] [PubMed] [Google Scholar]
- 3. Braithwaite C, Hafen TJ, Dean R, Lebaschi A, Guettler J, Bicos J. Outcomes of primary anterior cruciate ligament (ACL) repair for proximal tears: a systematic review and meta‐analysis. Cureus. 2024;16(4):59124. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Carulli C, Matassi F, Soderi S, Sirleo L, Munz G, Innocenti M. Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods. Knee Surg Sports Traumatol Arthrosc. 2017;25(4):1264–1271. [DOI] [PubMed] [Google Scholar]
- 5. Debieux P, Franciozi CE, Lenza M, et al. Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction. Cochrane Library. 2016;2016(7):CD009772. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. DeFroda S, Fice M, Tepper S, Bach BR. Our preferred technique for bone–patellar tendon–bone allograft preparation. Arthrosc Tech. 2021;10(11):e2591–e2596. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Djordjevic D, Petrovic M, Zuncic‐Djordjevic S, Stojiljkovic P, Golubovic I, Kadija M, et al. Application of two types of suspensory fixation in reconstruction of anterior cruciate ligament with a semitendinosus‐gracilis graft: a randomized prospective study. Vojnosanit Pregl. 2021;78(10):1053–1059. [Google Scholar]
- 8. Elias J, Kaplan M, Shah K, Bickford M, McNamara C, Ford E, et al. 4‐Strand hamstring versus single‐bundle quadriceps tendon grafts in anterior cruciate ligament reconstruction at 2 years: a systematic review and meta‐analysis of randomised controlled trials. J Exp Orthop. 2025;12(2):e70244. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Elmholt SB, Nielsen TG, Lind M. Correction: Fixed‐loop vs. adjustable‐loop cortical button devices for femoral fixation in ACL reconstruction – a systematic review and meta‐analysis. J Exp Orthop. 2022;9(1):112. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Gupta R, Bahadur R, Malhotra A, Masih GD, Sood M, Gupta P, et al. Outcome of hamstring autograft with preserved insertions compared with free hamstring autograft in anterior cruciate ligament surgery at 2‐year follow‐up. Arthroscopy. 2017;33(12):2208–2216. [DOI] [PubMed] [Google Scholar]
- 11. Gupta R, Bahadur R, Malhotra A, Masih GD, Gupta P. Anterior cruciate ligament reconstruction using hamstring tendon autograft with preserved insertions. Arthrosc Tech. 2016;5(2):e269–e274. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Ifarraguerri AM, Graham GD, White AB, Berk AN, Gachigi KK, Siparsky PN, et al. Two‐stage revision anterior cruciate ligament reconstruction reduces failure risk but leads to lesser clinical outcomes than single‐stage revision after primary anterior cruciate ligament graft failure: a retrospective cohort study. Knee Surg Relat Res. 2025;37(1):5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Järvelä S, Kiekara T, Suomalainen P, Järvelä T. Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction: a prospective randomized study with 10‐year results. Am J Sports Med. 2017;45(11):2578–2585. [DOI] [PubMed] [Google Scholar]
- 14. Karikis I, Ejerhed L, Sernert N, Rostgård‐Christensen L, Kartus J. Radiographic tibial tunnel assessment after anterior cruciate ligament reconstruction using hamstring tendon autografts and biocomposite screws: a prospective study with 5‐year follow‐up. Arthroscopy. 2017;33(12):2184–2194. [DOI] [PubMed] [Google Scholar]
- 15. Kataoka K, Hoshino Y, Nukuto K. Anterior cruciate ligament reconstruction: recent evolution and technical improvement. J Jt Surg Res. 2023;1(1):97–102. [Google Scholar]
- 16. Mayr R, Heinrichs CH, Eichinger M, Smekal V, Schmoelz W, Attal R. Preparation techniques for all‐inside ACL cortical button grafts: a biomechanical study. Knee Surg Sports Traumatol Arthrosc. 2016;24(9):2983–2989. [DOI] [PubMed] [Google Scholar]
- 17. McDermott E, DeFoor MT, Blaber OK, Aman ZS, DePhillipo NN, Dekker TJ. Biomechanical comparison of anterior cruciate ligament reconstruction fixation methods and implications on clinical outcomes. Annals Joint. 2023;8:15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. McGuinness LA, Higgins JPT. Risk‐of‐bias VISualization (robvis): an R package and Shiny web app for visualizing risk‐of‐bias assessments. Res Synth Methods. 2021;12(1):55–61. [DOI] [PubMed] [Google Scholar]
- 19. Mo IF, Harlem T, Faleide AGH, Strand T, Vindfeld S, Solheim E, et al. ACL reconstruction using quadrupled semitendinosus versus double‐stranded semitendinosus and gracilis autograft: 2‐year results from a prospective randomized controlled study. Am J Sports Med. 2024;52(8):1927–1936. [DOI] [PubMed] [Google Scholar]
- 20. Moré ADO, Pizzolatti ALA, Fancello EA, Roesler CRM. Biomechanical performance of Bio Cross‐Pin and EndoButton for ACL reconstruction at femoral side: a porcine model. Res Biomed Eng. 2016;32(1):28–34. [Google Scholar]
- 21. Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;1:n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Papalia R, Vasta S, D'Adamio S, Giacalone A, Maffulli N, Denaro V. Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction? Br Med Bull. 2014;109(1):19–29. [DOI] [PubMed] [Google Scholar]
- 23. Ranjan R, Gaba S, Goel L, Asif N, Kalra M, Kumar R, et al. In vivo comparison of a fixed loop (EndoButton CL) with an adjustable loop (TightRope RT) device for femoral fixation of the graft in ACL reconstruction: a prospective randomized study and a literature review. J Orthop Surg. 2018;26(3):2309499018799787. [DOI] [PubMed] [Google Scholar]
- 24. Roger J, Bertani A, Vigouroux F, Mottier F, Gaillard R, Have L, et al. ACL reconstruction using a quadruple semitendinosus graft with cortical fixations gives suitable isokinetic and clinical outcomes after 2 years. Knee Surg Sports Traumatol Arthrosc. 2020;28(8):2468–2477. [DOI] [PubMed] [Google Scholar]
- 25. Schünemann H, Brożek J, Guyatt G, Oxman A. GRADE handbook for grading quality of evidence and strength of recommendations for diagnostic tests and strategies. BMJ. 2013;336(7653):1106–1110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Sezer HB, Bohu Y, Hardy A, Coughlan A, Lefevre N. Effect of different screw materials on ACL reconstruction with the tape locking screw technique: a retrospective study from the FAST cohort. Orthop J Sports Med. 2024;12:23259671241258505. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Stener S, Ejerhed L, Sernert N, Laxdal G, Rostgård‐Christensen L, Kartus J. A long‐term, prospective, randomized study comparing biodegradable and metal interference screws in anterior cruciate ligament reconstruction surgery: radiographic results and clinical outcome. Am J Sports Med. 2010;38(8):1598–1605. [DOI] [PubMed] [Google Scholar]
- 28. Sterne JAC, Savović J, Page MJ, Elbers RG, Blencowe NS, Boutron I, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019;366:l4898. [DOI] [PubMed] [Google Scholar]
- 29. Sun K, Zhang J, Wang Y, Xia C, Zhang C, Yu T, et al. Arthroscopic reconstruction of the anterior cruciate ligament with hamstring tendon autograft and fresh‐frozen allograft: a prospective, randomized controlled study. Am J Sports Med. 2011;39(7):1430–1438. [DOI] [PubMed] [Google Scholar]
- 30. Suomalainen P, Järvelä T, Paakkala A, Kannus P, Järvinen M. Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction: a prospective randomized study with 5‐year results. Am J Sports Med. 2012;40(7):1511–1518. [DOI] [PubMed] [Google Scholar]
- 31. Suomalainen P, Moisala A‐S, Paakkala A, Kannus P, Järvelä T. Double‐bundle versus single‐bundle anterior cruciate ligament reconstruction: randomized clinical and magnetic resonance imaging study with 2‐year follow‐up. Am J Sports Med. 2011;39(8):1615–1623. [DOI] [PubMed] [Google Scholar]
- 32. Teng Y, Zhang X, Da L, Hu J, Wang H, Han H, et al. Whether sutures reduce the graft laceration caused by interference screw in anterior cruciate ligament reconstruction? A biomechanical study in vitro. BMC Musculoskelet Disord. 2021;22(1):571. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Weimann A, Rodieck M, Zantop T, Hassenpflug J, Petersen W. Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws. Arthroscopy. 2005;21(3):266–274. [DOI] [PubMed] [Google Scholar]
- 34. Xu B, Yin Y, Zhu Y, Yin Y, Fu W. Comparison of bioabsorbable and metallic interference screws for graft fixation during ACL reconstruction: a meta‐analysis of randomized controlled trials. Orthop J Sports Med. 2021;9(8):23259671211021577. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Yan L, Li JJ, Zhu Y, Liu H, Liu R, Zhao B, et al. Interference screws are more likely to perform better than cortical button and cross‐pin fixation for hamstring autograft in ACL reconstruction: A Bayesian network meta‐analysis. Knee Surg Sports Traumatol Arthrosc. 2021;29(6):1850–1861. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data extracted from each study is publicly available at each study's respective journal.