We thank Sun et al. for their interest in our article, “UltraTape and Sutures Combination Versus Conventional Sutures in Arthroscopic Rotator Cuff Repair: A 6-Month Retrospective Matched Cohort Study”, and for their constructive comments. Their concerns regarding temporal bias and methodology merit clarification. Here, we detail our study design and efforts to minimize bias, and discuss the interpretation and clinical value of real-world, retrospective cohort data in the context of new surgical technologies.
Keywords: Rotator cuff repair, UltraTape, Suture tape, Retrospective study, Temporal bias, Methodology
We thank Sun et al. [1] for their interest in our article, “UltraTape and Sutures Combination Versus Conventional Sutures in Arthroscopic Rotator Cuff Repair: A 6-Month Retrospective Matched Cohort Study” [2], and for their constructive comments.
The comparison of two consecutive time periods was a deliberate design choice reflecting the real-world introduction of UltraTape into our practice. This approach is commonly used when evaluating new surgical materials and allowed us to assess clinical impact under otherwise unchanged perioperative conditions. During both study periods, all procedures were performed by a single senior surgeon using the same single-row configuration, with identical anchor types (apart from UltraTape), no biologic augmentation, and an unchanged rehabilitation protocol. Patient selection criteria were stable across both cohorts.
To further minimize confounding, the groups were strictly matched for age, tear size, and preoperative shoulder stiffness—three of the strongest predictors of retear risk. Outcome assessment included ultrasound-confirmed tendon integrity and functional measures, ensuring objective and reliable evaluation. The longer operative time in the UltraTape group primarily reflected the additional handling required for tape constructs rather than a change in surgical efficiency or evolving technique. Similarly, the combination of improved lift-off strength and slightly lower patient satisfaction is more likely related to the biomechanical characteristics of tape constructs than to temporal effects, consistent with published biomechanical data [3].
We acknowledge that temporal bias is an inherent limitation of retrospective studies [4]. However, the single-surgeon design, stable rehabilitation pathway, and strict matching reduce this risk significantly, aligning with best practices for observational surgical research [5]. While we agree that future prospective randomized studies remain the gold standard, real-world retrospective comparisons such as ours are an important early step when new surgical materials are introduced.
Our findings—no reduction in retear rates despite biomechanical advantages, with mixed functional results—provide practical early evidence to guide clinical decision-making. We thank Sun et al. for engaging with our work and hope this dialogue encourages further investigation into suture-tape technology.
Acknowledgements
None.
Author contributions
All authors contributed to the writing and approval of this reply.
Funding
No funding was received for this work.
Data availability
No datasets were generated or analysed during the current study.
Declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Footnotes
The online version of the original article can be found at 10.1186/s13018-025-06178-0.
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Sun GX, Guan JC, Ma HL, Xu ZJ. Letter to the editor regarding ultratape and sutures combination versus conventional sutures…. J Orthop Surg Res. 2025 (in press).
- 2.Hawa A, Bilbrough J, Hayek C, Shenouda M, Murrell GAC. UltraTape and sutures combination versus conventional sutures in arthroscopic rotator cuff repair: a 6-month retrospective matched cohort study. J Orthop Surg Res. 2025;20:677. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Nie S, Qin H, Tan H, et al. Suture tape anchors for enhancing healing in rotator cuff tears: a retrospective cohort study. BMC Musculoskelet Disord. 2025;26:470. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Shultz BN, Galivanche AR, Ottesen TD, et al. The use of older versus newer data in the NSQIP database influences outcomes studies. J Am Acad Orthop Surg Glob Res Rev. 2019;3(10):e19. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Devick KL, Makhni EC, Johnson AH, et al. Avoiding systematic bias in orthopedics research through observational study design. J Bone Joint Surg Am. 2022;104:e49. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
No datasets were generated or analysed during the current study.