Abstract
Background
Artificial intelligence (AI) has shown promise in transforming health care, particularly in cardiology. However, there is a lack of high-quality evidence demonstrating its impact on crucial clinical outcomes.
Objectives
The purpose of this study was to synthesize existing evidence from randomized controlled trials (RCTs) on the application of AI in cardiology, evaluating its impact on key clinical outcomes.
Methods
We conducted a systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, searching MEDLINE, Web of Science, and the Cochrane Library from inception to November 2024. We included RCTs evaluating machine learning models compared to traditional methods in cardiovascular care. Primary outcomes focused on patient-important metrics, while secondary outcomes covered time and resource savings.
Results
Eleven RCTs met the inclusion criteria. Studies were conducted between 2021 and 2024, with 81.2% being multicenter trials. Five studies (45.5%) reported improvements in clinical events, 6 (54.5%) showed enhanced diagnostic accuracy and early detection, and 3 (27.3%) demonstrated improved resource utilization.
Conclusions
This review highlights AI's potential to enhance cardiovascular care through improved early detection, diagnostic accuracy, and resource efficiency. However, the limited number of RCTs indicates a need for more high-quality studies to validate AI’s effectiveness across various clinical domains.
Key words: artificial intelligence, cardiovascular care, clinical outcome, machine learning, randomized controlled trial, systematic review
Central Illustration
Artificial intelligence (AI) technologies promise to transform health care by providing tools that can assist clinicians in making more accurate and timely decisions, ultimately improving patient outcomes. This potential is particularly evident in cardiology,1,2 a specialty characterized by its complexity and the abundance of data available from various diagnostic tools.1, 2, 3 AI applications in cardiology range from detecting arrhythmias4,5 and predicting heart failure to assessing the severity of coronary artery disease (CAD),6 imaging analysis, personalized treatment planning, and risk stratification. The primary advantage of AI lies in its ability to analyze vast amounts of data quickly and accurately, providing insights that may be beyond human capability.7
Despite the promising performance metrics of AI,8 there remains a lack of high-quality evidence demonstrating its impact on clinical outcomes such as mortality, hospitalization rates, major adverse cardiovascular events, treatment response rates, and patient-reported outcomes.9,10 The evidence gap is largely due to the limited number of prospective randomized controlled trials (RCTs) evaluating AI applications in real-world clinical settings.11 High-quality RCTs are essential to ensure that these technologies reliably improve patient outcomes in everyday practice.9,11, 12, 13 Several recent reviews have explored AI in cardiovascular care, but most included heterogeneous clinical domains, lacked systematic trial-level risk-of-bias assessment, or predated key reporting standards such as CONSORT-AI (Consolidated Standards of Reporting Trials–Artificial Intelligence) and SPIRIT-AI (Standard Protocol Items: Recommendations for Interventional Trials–Artificial Intelligence).14, 15, 16, 17, 18 To our knowledge, no prior review has focused exclusively on RCTs in cardiology while evaluating risk of bias and adherence to AI-specific reporting guidelines. This systematic review aims to synthesize the existing evidence from RCTs on the application of AI in cardiology, and specifically, to identify which AI interventions have been validated against gold standard practices, assess their impact on key clinical outcomes, and pinpoint gaps that should guide future research.
Methods
Search strategy
We conducted a systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for critical appraisal and data extraction.19 We searched peer-reviewed original articles evaluating the use of machine learning models compared to traditional methods in various applications of cardiovascular care as evaluated by RCTs. The search was performed using MEDLINE, Web of Science, and the Cochrane Library from inception to November 2024, using keywords such as “Artificial intelligence,” “Myocardial infarction,” “Heart failure,” and “Randomized controlled trial,” Supplemental Appendix 1 provides the complete search strategy including all keywords used. Supplemental Appendix 2 represents the PRISMA checklist. The data underlying this systematic review are derived from publicly available sources and do not require Institutional Review Board approval.
Study selection and data extraction
Two authors independently reviewed titles and abstracts based on predetermined eligibility criteria documented in our study protocol registered with PROSPERO (International Prospective Register of Systematic Reviews) (CRD42024548371). We included only peer-reviewed, full-text articles of RCTs that evaluate the use of machine learning models in cardiovascular care. A third reviewer resolved disagreements between the 2 reviewers. Backward and forward snowballing techniques were employed, examining reference lists and citation tracking of the included articles to identify additional relevant studies. The 2 authors then independently evaluated the full-text studies. To avoid duplication and ensure data integrity, we screened for overlapping populations and multiple publications by cross-referencing trial registration numbers, study settings, sample sizes, recruitment periods, and author lists. No duplicate reports were identified, and each included RCT represented a unique study. Figure 1 illustrates a flowchart of the screening and inclusion process. We utilized a standardized data extraction sheet to gather relevant information from the reviewed studies (Table 1).
Figure 1.
PRISMA Flow Diagram
Studies were excluded based on title and abstract screening focusing on RCTs that use machine learning in cardiology. PRISMA = Preferred Reporting Items for Systematic Reviews and Meta-Analyses; RCTs = randomized controlled trials.
Table 1.
Metadata of the Included Trials
| First Author | Title | Journal | Country | Year of Publication |
|---|---|---|---|---|
| Yao et al25 | Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial | Nature Medicine | USA | 2021 |
| Huang et al29 | Portable Device Improves the Detection of Atrial Fibrillation After Ablation | International Heart Journal | China | 2021 |
| Hill et al26 | Identification of undiagnosed atrial fibrillation using a machine learning risk prediction algorithm and diagnostic testing (pulse-AI) in primary care: a multi-centre randomized controlled trial in England | European Heart Journal - Digital Health | England | 2022 |
| Sandhu et al31 | Incidental Coronary Artery Calcium: Opportunistic Screening of Previous Nongated Chest Computed Tomography Scans to Improve Statin Rates (NOTIFY-1 Project) | Circulation | USA | 2022 |
| De Backer et al32 | Impact of Computational Modeling on Transcatheter Left Atrial Appendage Closure Efficiency and Outcomes |
JACC cardiovascular interventions | Denmark | 2023 |
| He et al33 | Blinded, randomized trial of sonographer vs AI cardiac function assessment | Nature Medicine | USA | 2023 |
| Yang et al30 | On-Site Computed Tomography–Derived Fractional Flow Reserve to Guide Management Of patients with Stable Coronary Artery Disease: The TARGET Randomized Trial | Circulation | China | 2023 |
| Lin et al (2024a)24 | AI-enabled electrocardiography alert Intervention and all-cause mortality: a pragmatic randomized clinical trial | Nature Medicine | Taiwan | 2024 |
| Adedinsewo et al27 | Artificial intelligence-guided screening for Cardiomyopathies in an obstetric population: a pragmatic randomized clinical trial | Nature Medicine | Nigeria | 2024 |
| Lin et al (2024b)28 | Artificial Intelligence-Powered Rapid ST-Elevation Myocardial Infarction Identification via Electrocardiogram (ARISE): A Pragmatic Randomized Controlled Trial | NEJM AI | Taiwan | 2024 |
| Upton et al34 | PROTEUS: A Prospective RCT Evaluating Use of AI in Stress Echocardiography | NEJM AI | England | 2024 |
Outcomes and evaluation metrics
Primary outcomes focused on patient-important metrics, including mortality, hospitalization rates, major adverse cardiovascular events, treatment adherence, and early diagnosis, as RCTs are considered the gold standard for evaluating improvements in clinical management.16 Secondary outcomes addressed the optimization of resource allocation, such as time and cost savings and reductions in manpower, reflecting the transformative role of AI in reshaping health care operations.20 Notably, none of the included studies assessed patient-reported outcome measures, which represent a critical dimension in evaluating the effectiveness of health care interventions.21
Risk of bias
The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was utilized to systematically evaluate the quality and diagnostic accuracy of the studies under review across 4 critical domains: patient selection, index test, reference standard, and flow and timing. In addition, we also assessed the risk of bias related to funding and conflicts of interest. Although QUADAS-AI remains under development, it is expected to serve as a vital tool for evaluating the risk of bias in AI-driven diagnostic accuracy studies.22,23
The quality of randomization varied across studies, from simple methods (eg, random number tables, record-based assignment) to more robust techniques like stratified or block randomization with independent oversight. This heterogeneity may influence the internal validity of findings and highlights the need for transparent reporting in future AI-related RCTs. A summary of randomization methods is provided in Supplemental Table 3.
Results
Our search retrieved 930 study records after deduplication (Figure 1). After screening titles and abstracts, 43 articles were retained for full-text review. Of these, 32 were excluded, leaving 11 RCTs included in our systematic review. The geographic distribution of these studies was 3 from the United States (37.5%), 2 from China, England, and Taiwan (each 18.2%), and 1 each from Nigeria and Denmark (12.5%). The studies were conducted between 2021 and 2024. Most studies (81.2%) were multicenter trials. The most common AI application was to electrocardiography (ECG) data (54.5%), followed by computed tomography (27.3%) and echocardiography (18.2%). Studies were distributed between diagnosis, prevention, and screening (72.7%) and procedural optimization and resource efficiency (27.3%) (Table 2, Figure 2).
Table 2.
Technical Information About the Included Trials
| First Author | Main Domain | Study Design | Single/Multisite | Number of Participants | AI/Prediction Task | Study Objective | Added Value With AI | Ethical Statement | Funding | Conflict of Interest |
|---|---|---|---|---|---|---|---|---|---|---|
| Yao et al25 | ECG, prevention, and screening | Prospective RCT | Multisite | 358 clinicians and 22,641 patients | AI-ECG alert for early diagnosis of low LVEF | To evaluate whether an AI-enabled ECG can serve as a screening tool detecting low EF in routine practice. | Increased the diagnosis of low EF (1.6% in the control arm vs 2.1% in the intervention arm). In patients with a high likelihood of low EF (14.5% vs 19.5%, respectively) | IRB approval and informed consent were obtained | The Mayo Clinic Robert D. And Patricia E. Kern Center for the Science of Health Care Delivery | Multiple authors declare financial benefits from using the AI-ECG system. |
| Huang et al29 | ECG, prevention and screening | Prospective RCT | Single center | 218 patients | AI-enabled automated AF detection | Detection of asymptomatic recurrences of AF after ablation by a handheld, AI-enabled, ECG monitor | AF-free survival rates were 64.2% in the test group and 78.9% in the control group (P = 0.0163). There was greater adherence to oral anticoagulation in the test group (51.0% vs 25.4%, P = 0.0052). | IRB approval and informed consent were obtained | The National Natural Science Foundation of China | None |
| Hill et al26 | ECG, prevention, and screening | Prospective RCT | Multisite | 23,745 patients | Machine learning risk prediction for undiagnosed AF | To evaluate a machine learning algorithm for detecting AF in a primary care setting. | 9.41% of the intervention group received AF and related arrhythmia diagnoses vs 4.93% in the control group | IRB approval and informed consent were obtained | Bristol Myers Squibb Pharmaceuticals Ltd and Pfizer. One of the authors is funded by the NIHR Biomedical Research, Centre, Oxford. | Multiple authors declared a conflict of interest. |
| Sandhu et al31 | CT, prevention and screening | Prospective RCT | Multisite | 2,113 patients | AI-based opportunistic screening for coronary artery calcium on a nongated chest CT | To evaluate the effect of notifying clinicians about high-risk patients with incidental coronary artery calcium | Statins were prescribed to 51.2% of the notification arm vs 6.9% of the usual care arm (P < 0.001). 15.1% of the notification arm underwent testing for CAD compared to 2.3% in the usual care arm (P = 0.008). | Exempt from human subject research requirements by the Stanford IRB. | The Stanford University Human-Centered Artificial Intelligence Seed Grant. | Multiple authors declared a conflict of interest. |
| De Backer et al32 | CT, cardiac device implantation | Prospective RCT | Multisite | 200 patients | AI-enabled CT-based computational modeling for planning transcatheter left atrial appendage closure | To assess the effect of AI-driven CT-based computational modeling in planning transcatheter left atrial appendage closure on procedural efficiency and patient outcomes. |
Improved patient outcome: complete left atrial appendage closure with no residual leak or disc retraction was observed in 44.0% of cases vs 61.1% (RR: 1.44; 95% CI: 1.05-1.98; P = 0.03). Improved procedural efficiency: fewer Amulet devices used (103 vs 118; P < 0.001) and fewer device repositioning (104 vs 195; P < 0.001) in the CT + simulation group. |
IRB approval | Abbott (United States) and Feops NV (Belgium) | Multiple authors declared a conflict of interest |
| He et al33 | Echocardiography, diagnosis | Retrospective RCT | Single center | 25 sonographers, 10 cardiologists, and 3,495 patients | AI initial interpretation workflow of echocardiography and LVEF | To compare the accuracy and efficiency of initial LVEF assessments by AI vs sonographers. | The cardiologist's final assessment significantly altered 16.8% of AI group studies and 27.2% of the sonographer’s group (95% CI: −13.2% to −7.7%). The AI-guided workflow reduced the time required for both sonographers and cardiologists. | IRB approval with waiver of individual consent | No external funding was obtained for this study | Stanford University is in the process of applying for a patent application covering video-based deep learning models for assessing cardiac function |
| Yang et al30 | CT-fractional flow reserve, diagnosis | Prospective RCT | Multisite | 1,216 patients | Identification of CAD in CT-fractional flow reserve | To compare the on-site CT-fractional flow reserve strategy using machine learning to standard care (stress test) in diagnosing stable CAD. | The intervention group had a lower percentage of patients undergoing ICA without obstructive disease (28.3% vs 46.2%; P < 0.001). | IRB approval and informed consent were obtained | The National Key Research and Development Program of China and the Beijing Nova Program | None |
| Lin et al (2024a)24 | ECG, prevention, and screening | Prospective RCT | Multisite | 39 clinicians and 15,965 patients | AI-enabled ECG to identify hospitalized patients with a high risk of mortality |
To evaluate whether an AI-enabled ECG alert can reduce all-cause mortality among high-risk hospitalized patients | All-cause mortality reduction - 3.6% in the intervention group vs 4.3% in the control group. For high-risk patients, there is a reduction in the risk of cardiac death (0.2% vs 2.4%, respectively) | IRB approval and informed consent were obtained | The National Science and Technology Council, Taiwan; The Cheng Hsin General Hospital, Taiwan; and the Medical Affairs Bureau, Taiwan. | Multiple authors declare financial benefits from using the AI-ECG system. |
| Adedinsewo et al27 | Auscultation and ECG, prevention and screening | Prospective RCT | Multisite | 1,232 patients | AI-enabled digital stethoscope and ECG to identify LV systolic dysfunction | To assess AI-guided screening for peripartum cardiomyopathy compared to standard of care | LV systolic dysfunction was detected in 4.1% of the intervention group vs 2.0% of the control group (P = 0.032) | IRB approval and informed consent were obtained | The Mayo Clinic and the National Institutes of Health | Multiple authors declare financial benefits from using the AI-ECG system |
| Lin et al (2024b)28 | ECG | Prospective RCT | Multisite | 43,234 patients | AI-ECG to detect STEMI | To evaluate the impact of AI-ECG-guided alerts on treatment delay and diagnostic accuracy in STEMI cases | For patients in the emergency department, the median door-to-balloon time was 82.0 minutes in the intervention group compared with 96.0 minutes in the control group (P = 0.002). | IRB approval, with informed consent waived | The National Science and Technology Council, Taiwan | None |
| Upton et al34 | Echocardiography | Prospective RCT | Multisite | 2,341 patients | AI-augmented interpretation of stress echocardiography | To evaluate the accuracy of AI-augmented interpretation of stress echocardiography compared to standard care | None | IRB approval and informed consent were obtained | Accelerated Access Collaborative, NHSX, and the National Institute for Health Research | Multiple authors declared a conflict of interest. |
AF = atrial fibrillation; AI = artificial intelligence; CAD = coronary artery disease; ECG = electrocardiography; EF = ejection fraction; IRB = Institutional Review Board; LV = left ventricle; RCT = randomized controlled trial.
Figure 2.
Summary of Included Studies by Endpoint and Result
The matrix groups studies by endpoint category, clinical outcomes, diagnosis and screening, or resource utilization, and by whether the artificial intelligence intervention showed a statistically significant improvement or no statistically significant improvement. Each tile represents one study labeled by first author and year.
Outcomes by imaging modality
Synthesizing outcomes across imaging modalities revealed distinct patterns of AI effectiveness in cardiovascular applications.
ECG-based AI applications (6 studies, 54.5%) demonstrated consistent clinical benefits across diverse contexts: mortality reduction in hospitalized patients (HR: 0.83),24 improved detection of low ejection fraction (EF) (OR: 1.32),25 enhanced arrhythmia diagnosis (OR: 2.24),26 increased left ventricle (LV) dysfunction detection in peripartum women (OR: 2.12),27 and reduced door-to-balloon times in ST-segment elevation myocardial infarction (STEMI) (14.6% reduction),28 though with mixed results for postablation monitoring.29
Computed tomography (CT)-based AI applications (3 studies, 27.3%) showed strongest impact on clinical workflows and resource optimization, significantly reducing unnecessary invasive coronary angiography (39.4% reduction),30 increasing preventive therapy adoption (7.4-fold increase in statin prescriptions),31 and improving procedural outcomes in device implantation (38.9% improvement in success rate) while reducing device use and manipulation.32
Echocardiography AI applications (2 studies, 18.2%) demonstrated contrasting outcomes: significant workflow efficiency gains and reduced interpretation variability in routine assessments (38.2% fewer substantial changes between initial and final assessments),33 but insufficient diagnostic performance in stress echocardiography for CAD detection.34
Clinical outcomes versus operational benefit
AI interventions frequently produced stronger operational than clinical outcomes. Operationally, AI consistently enhanced workflow efficiency by reducing variability in echocardiographic interpretation,33 shortening door-to-balloon time in STEMI,28 and optimizing procedural resource use in CT-guided device implantation.32 In contrast, improvements in clinical endpoints, such as reduced mortality,24 were less frequent, often modest in magnitude, or demonstrated significance primarily in subgroup analyses.
AI in population-based settings versus specialized clinical contexts
AI's effectiveness varied by clinical setting. Studies conducted in high-volume settings, such as primary care atrial fibrillation (AF) screening,26 population-based low EF detection,25 and preventive coronary artery calcium (CAC) screening,31 demonstrated consistent diagnostic and preventive therapy benefits, highlighting AI’s strength in managing standardized, large-scale data. Conversely, specialized procedural contexts, such as stress echocardiography for CAD,34 showed more limited diagnostic accuracy, indicating complexities that may require more tailored AI algorithms or integrated human oversight.
Early detection and prevention
Across seven RCTs examining early detection and prevention, AI interventions consistently improved diagnostic rates and accelerated identification of high-risk patients, especially in large-scale screening contexts. ECG-based algorithms notably enhanced detection rates of clinically significant cardiac conditions such as low EF, AF, and myocardial infarction, facilitating timely interventions. While absolute improvements in some outcomes (eg, mortality) were modest, AI tools demonstrated clear value in risk stratification, significantly increasing targeted downstream testing and therapy initiation. These consistent, directional benefits across varied clinical settings indicate AI’s potential as an effective frontline screening and preventive tool.
Hill et al26 conducted a study involving 23,745 participants across 6 primary care clinics in England, where machine learning–based AF screening in the intervention arm identified high-risk patients for diagnostic testing. AF and related arrhythmias were diagnosed in 5.63% of high-risk participants in the intervention group, compared to 4.93% in the control arm (OR: 1.15; 95% CI: 0.77-1.73; P = 0.486). High-risk participants in the intervention arm who underwent diagnostic testing were twice as likely to receive arrhythmia diagnoses compared to routine care (9.41% vs 4.93%; OR: 2.24; 95% CI: 1.31-3.73; P = 0.003).
Another RCT by Yao et al25 with 22,641 patients from 45 Mayo Clinic practices assigned the intervention group AI alerts for low EF based on ECGs, while the control group received standard care. The intervention group had a higher diagnosis rate of low EF (2.1%) compared to the control group (1.6%) (OR: 1.32; 95% CI: 1.08-1.61; P = 0.007). Echocardiography utilization was higher in the intervention group (49.6% vs 38.1%; P < 0.001), as was the diagnosis rate of low EF (19.5% vs 14.5%; OR: 1.43; 95% CI: 1.08-1.91; P = 0.01). Similarly, Lin et al (2024a)24 conducted a multisite RCT involving 15,965 patients at both an academic and a community hospital in Taiwan, with the intervention group receiving AI-ECG alerts for high mortality risk, prompting intensive care, while the control group received standard care. The intervention group showed a significant reduction in all-cause mortality within 90 days (3.6% vs 4.3%; HR: 0.83; 95% CI: 0.70-0.99; P = 0.04). Among high-risk patients, mortality fell from 23.0% to 16.0% (HR: 0.69; 95% CI: 0.53-0.90; P = 0.006). Increased Intensive Care Unit (ICU) admissions (HR: 1.40; 95% CI: 1.06-1.85; P = 0.016) and more frequent echocardiography (HR: 1.36; 95% CI: 1.15-1.61; P < 0.001) were observed.
Huang et al29 evaluated the detection of asymptomatic AF recurrences using a handheld AI-enabled ECG monitor (BigThumb) in postablation patients. 218 participants were randomized into an intervention arm using BigThumb and a control arm with traditional follow-up. The AF-free survival rate was higher in the control arm (78.9% vs 64.2%; P = 0.0163). Adherence to oral anticoagulation was better in the intervention arm (51.0% vs 25.4%; P = 0.0052).
Sandhu et al31 implemented a deep learning algorithm for CAC screening in patients without known atherosclerotic cardiovascular disease who had a nongated chest CT scan. Participants with positive CAC were randomized into notification (intervention) or usual care (control) arms. The intervention significantly increased statin prescriptions (51.2% vs 6.9%; P < 0.001) and CAD testing (15.1% vs 2.3%; P = 0.008), with lower low-density lipoprotein (LDL) levels during follow-up in the intervention group (97.2 mg/dL [SD: 30.3] vs 115.3 mg/dL [SD: 29.4], P = 0.005, respectively).
Lin et al (2024b)28 conducted another multicenter RCT involving 43,234 patients across 2 medical centers in Taiwan to evaluate AI-ECG for STEMI identification and alert, focusing on treatment time reduction. Patients were cluster-randomized daily, with on-duty cardiologists in the intervention group receiving SMS alerts for potential STEMI cases identified by the system, while the control group followed standard care. The intervention significantly reduced door-to-balloon time from 96.0 to 82.0 minutes (P = 0.002). Although no significant differences were observed in secondary clinical outcomes, the AI-ECG system demonstrated a high positive predictive value of 89.5% and a negative predictive value of 99.9%.
Adedinsewo et al27 conducted a pragmatic, RCT in 6 hospitals in Nigeria to assess Food and Drug Administration (FDA) - approved, AI-guided screening for peripartum cardiomyopathy in 1,232 women, comparing AI ECG and stethoscope screening to standard care. AI-guided screening detected LV systolic dysfunction in 4.1% of women in the intervention group vs 2.0% in the control group (OR: 2.12; 95% CI: 1.05-4.27; P = 0.032). Although the AI-ECG alone did not show a statistically significant difference, the digital stethoscope demonstrated 95.7% sensitivity and Area Under the Curve (AUC) of 0.976. The intervention required a number needed-to-screen of 47 to detect one additional LV systolic dysfunction case, highlighting its utility in low-resource settings.
Upton et al34 performed a multicenter RCT at 20 centers across the United Kingdom involving 2,341 participants undergoing stress echocardiography for significant CAD. Participants were randomized into an intervention group, where AI was used to augment test interpretation, or a control group, where tests were interpreted per standard protocol. The AI-augmented approach showed an Area Under the Receiver Operating Characteristic (AUROC) of 0.63 (95% CI: 0.43-0.83) compared to 0.55 (95% CI, 0.33-0.80) in the control group, which did not meet the noninferiority margin for detecting acute coronary events.
Procedural optimization and resource efficiency
Three RCTs demonstrated AI’s substantial role in optimizing procedural workflows and resource utilization. AI-driven echocardiography and CT-based planning significantly reduced procedural variability, shortened interpretation and procedure times, decreased the frequency of unnecessary invasive procedures, and improved device implantation outcomes. Although clinical outcomes such as major cardiovascular events were not significantly impacted, operational efficiency gains, including reduced clinician workload and procedural costs, show AI’s immediate practical benefits. These results suggest a meaningful role for AI as a complement to clinician expertise, enhancing efficiency, consistency, and resource management, especially in high-volume cardiovascular care settings.
He et al33 compared AI with sonographers for initial echocardiography assessments in a noninferiority trial with 3,495 studies, using the cardiologist’s final assessment as the reference. The AI group had a significantly lower proportion of substantial changes between initial and final left ventricular ejection fraction (LVEF) assessments (16.8% vs 27.2%; 95% CI: −13.2% to −7.7%; P < 0.001), with a lower absolute difference in LVEF (2.79% vs 3.77%; P < 0.001). Notable time savings were observed for sonographers (median 119s for AI vs 0s; P < 0.001) and cardiologists (median 54s for AI vs 64s, P < 0.001). The study demonstrates that AI-guided assessments are noninferior to sonographer assessments, with benefits in both accuracy and efficiency.
De Backer et al32 investigated the use of AI-enabled CT planning for transcatheter left atrial appendage closure. The study randomized 200 patients to standard planning or CT simulation-based planning. The AI group showed improved patient outcomes with a higher complete closure rate (61.1% vs 44.0%; relative risk (RR): 1.44; 95% CI: 1.05-1.98; P = 0.03). Procedural efficiency improved with 15% fewer devices used (103 vs 118; P < 0.001) and a 50% reduction in device repositioning (104 vs 195; P < 0.001).
Yang et al30 compared an on-site CT-fractional flow reserve strategy using machine learning vs a standard stress test in the diagnosis of stable CAD. The intervention group had fewer patients referred for angiography without obstructive CAD or intervention within 90 days (28.3% vs 46.2%; P < 0.001). Major adverse cardiovascular events at 1 year did not significantly differ (HR: 0.88; 95% CI: 0.59-1.30).
Risk of bias
The QUADAS-2 tool was used to evaluate the risk of bias in patient selection, the index test, the reference standard, and flow and timing (Figure 3). Regarding patient selection, all the included studies are RCTs with well-defined population selection criteria that adhered to a randomization process, most of them conducted across multiple centers. In the evaluation of the index test, Huang et al used a portable device to detect AF after an ablation procedure. The device's monitoring frequency was lower during nighttime, which could indicate a potential inconsistency in how the index test (BigThumb ECG device) was applied. Other than this, all studies applied a consistent methodology for the index test by the utilization of AI. Regarding the reference test risk of bias, the eleven studies consistently used either the gold standard test or actual clinical outcomes as the reference test, indicating the lowest risk of bias. In terms of flow and timing, Yang et al used routine chest CT as a screening tool for CAC. The extended time gap (median of 857 days) between the initial chest CT scan and the notification of CAC findings could potentially impact the effectiveness of the intervention, as the timely initiation of preventive measures, such as statin therapy, is crucial for reducing cardiovascular risk. In addition, we assessed the risk of bias related to funding and conflicts of interest. In this regard, seven out of eleven studies (63.6%) were found to have a moderate to high risk of bias, indicated by potential personal gain for the authors or the funding organizations from the successful implementation of the AI tools. In addition, only 5 of 11 studies declared adherence to AI-specific reporting guidelines such as CONSORT-AI and SPIRIT-AI.
Figure 3.
Assessment of the Risk of Bias
The QUADAS-2 tool was used to evaluate the risk of bias in patient selection, the index test, the reference standard, and flow and timing. In addition, assessment of the risk of bias due to funding and conflict of interest. QUADAS-2 = The Quality Assessment of Diagnostic Accuracy Studies-2.
As AI in health care research matures, several reporting guidelines, including CONSORT-AI, SPIRIT-AI, PRISMA-AI, Standards for Reporting Diagnostic Accuracy — Artificial Intelligence (STARD-AI), and others have been introduced or are under development.35, 36, 37, 38, 39, 40, 41, 42, 43, 44 These tools aim to standardize and enhance the quality, transparency, and reproducibility of AI-related clinical research. Our review found that only 5 of 11 RCTs adhered to SPIRIT-AI or CONSORT-AI, demonstrating a gap in standardization. A summary of the different guidelines and adherence is in Supplemental Tables 4 and 5. This lack of alignment with established reporting underscores the urgent need for broader adoption of these standards in future studies.
Discussion
Our systematic review evaluates the objective impact of AI in cardiology, focusing on the outcomes reported in RCTs. After a screening and full-text review process, eleven RCTs were included. These studies explored various AI applications across different modalities, such as ECG, echocardiography, and cardiac CT, while measuring a range of clinical and operational outcomes. Five studies (45.5%) reported improvements in clinical outcomes, 6 studies (54.5%) demonstrated enhanced diagnostic accuracy and early detection, and 3 studies (27.3%) showed improved resource utilization (Central Illustration).
Central Illustration.
Impact of AI in Cardiovascular Care: Insights and Gaps
This central illustration summarizes the key findings of our systematic review of randomized controlled trials evaluating AI applications in cardiovascular care. It highlights the main AI technologies (imaging analysis, risk prediction, and clinical decision support) and illustrates their flow into randomized trial designs. Outcomes and insights include improved clinical events (45.5% of studies), enhanced diagnostic accuracy and early detection (54.5%), and improved resource utilization (27.3%). Key limitations and gaps identified in the current evidence include the limited number of high-quality RCTs and potential bias due to funding and conflicts of interest. AI = artificial intelligence; other abbreviation as in Figure 1.
Previous systematic reviews have shown the added value of leveraging AI in clinical practice to improve prediction and diagnostic accuracy, as well as personalize treatment strategies in various modalities such as heart failure and cardiomyopathy detection,45 left ventricular hypertrophy identification,46 interpretation of ECG,47 and cardiac stress tests,8 valvular disease diagnosis,48 and transcatheter aortic valve implantation risk stratification.49 Despite significant research indicating that medical AI models can perform as well as or better than clinicians across various tasks and specialties, some of these models have only been tested retrospectively. In addition, several recent reviews have surveyed AI in cardiology: Moosavi et al17 offered a scoping review through 2023, Zhou et al16 systematically examined AI RCTs across health care before CONSORT-AI, Plana et al15 covered machine learning trials broadly through 2021 without emphasis on cardiovascular care, and Elias, Jain et al14,18 provided narrative advances without methodological appraisal. Yet none focus solely on cardiovascular RCTs published up to November 2024, apply a tailored QUADAS-2 risk-of-bias assessment including randomization audits and funding/conflict of interest analyses, or evaluate adherence to CONSORT-AI and SPIRIT-AI guidelines. Our review directly addresses these limitations, delivering the most current, comprehensive synthesis of randomized evidence for AI’s real-world clinical impact in cardiovascular care.
To integrate AI-based applications into routine clinical practice, their added value must be reliably demonstrated through rigorous evaluation. In particular, AI tools must show improvement in clinical outcomes such as reductions in mortality, hospitalization, and major adverse cardiovascular events or offer clear operational benefits, including enhanced efficiency, reduced clinician workload, or lower health care costs. These capabilities must be confirmed in prospective, well-designed randomized trials to ensure both efficacy and real-world applicability. As an alternative to clinical outcomes, these technologies should prove to be as good as a physician but with the ability to reduce costs or improve clinician time resources. This characteristic needs to be proven by clinical studies. Well-designed studies with robust methodologies are pivotal to accurately assess real-world clinical outcomes, which might differ when testing a machine learning model in lab settings. Hence, RCTs are crucial for validating those AI algorithms across diverse populations, data sources, and devices, ensuring generalizability and reducing bias.50 They also demonstrate the value proposition of AI tools in real-world settings, showing how AI can improve clinical workflows by saving time, reducing hospitalizations, and enabling early diagnosis and intervention.
A clear assessment of the risk of bias in these studies is crucial. As shown by Han et al, there is growing use of AI in clinical trials with promising results, but ensuring practical application in health care requires more than just broad external validation. Instead of focusing solely on multicenter studies, we must prioritize reliability across sites through recurring local validation, diverse outcome measures, and improved reporting to address the challenges of generalizability and site-specific performance.11,51 They demonstrated that a significant proportion of AI RCTs are concentrated in gastroenterology (43%) and radiology (13%), with most studies conducted in the United States, followed by China. There's also a notable gap in primary care research compared to specialty care, presenting an opportunity for future studies. Learning from other fields like gastroenterology and radiology, which have concentrated a significant number of AI RCTs, can guide better trial design in cardiology by incorporating lessons on trial structure, data diversity, and outcome validation.52 In this systematic review, we also highlight the risk of bias related to funding and conflicts of interest. To mitigate potential biases from industry involvement, hospitals and clinical key opinion leaders must take a proactive role in conducting and leading AI research. Their involvement can help maintain scientific rigor, ensure patient-centered outcomes, and reduce the influence of commercial interests. By fostering a culture of clinical leadership in AI research, health care institutions can become leaders in driving the responsible integration of AI into medical practice.
Limitations of current evidence and future research directions
AI has the potential to transform clinical practice significantly; however, several challenges must be addressed to fully realize its benefits. A primary concern is the availability of high-quality medical data. Most RCTs have focused on imaging data or ECG pattern recognition rather than broader clinical data. This narrow focus may be due to difficulties in accessing large-scale, structured clinical data sets like electronic health records. The lack of comprehensive, high-quality clinical data limits the development of AI models that could incorporate a wider range of patient information, such as demographics and lab results. Future research should aim to utilize these data sources to create more personalized and actionable AI tools for patient care.
Issues related to data privacy and confidentiality, informed consent, and patient autonomy are particularly pressing. Additionally, the increasing threat of cybersecurity breaches requires caution and the reinforcement of protective measures. It is crucial to influence the development of ethical and legal guidelines to ensure the safe integration of deep learning technologies in medical practice. Addressing these challenges will be vital for fostering trust among patients and maintaining the integrity of the clinician-patient relationship.9,53
Our systematic review is constrained by several limitations. This is a rapidly evolving field, with all the studies identified published within the last 3 years, reflecting the novelty of AI applications in cardiology. However, there remains a significant gap in high-quality, large-scale research. Notably, while we found only a small number of RCTs addressing AI in cardiovascular care, and even fewer focused on hard clinical outcomes, the number of FDA-cleared AI-enabled cardiology applications already exceeds a hundred.54 This discrepancy reflects a broader challenge in the regulatory landscape, where clearance is often based on technical performance or retrospective validation without prospective data. Although a systematic assessment of FDA-cleared tools was beyond the scope of this review, future efforts should prioritize integrating robust clinical trial evidence into the approval pathway to ensure safety, efficacy, and clinical value. Given cardiology's strong reliance on evidence-based medicine, this lack of robust data is a key limitation, highlighting the need for more RCTs to assess AI's clinical impact. This also indicates that the implementation of AI in this field has been relatively slow. This is partly due to the limited AI-oriented management and education among cardiologists. Many clinicians lack the necessary training to incorporate AI into their practice effectively. Educational programs focused on AI could empower cardiologists to lead the integration of these tools, accelerating their adoption in routine care. Additionally, the heterogeneity observed in study outcome measures, patient populations, and AI applications complicates the ability to draw definitive conclusions across the literature. This variability not only poses challenges for synthesizing results but also limits the feasibility of conducting a meta-analysis and therefore standard publication bias assessments such as funnel plots or Egger’s test could not be applied. Lastly, given the rapid pace of AI research, development, and adoption, new studies may have been published after our systematic review search was completed.
Conclusions
This review highlights AI's potential to enhance cardiovascular care through improved early detection, diagnostic accuracy, and resource efficiency. However, the limited number of RCTs indicates a need for more high-quality studies to validate AI’s effectiveness across various clinical domains.
Perspectives.
COMPETENCY IN MEDICAL KNOWLEDGE AND PATIENT CARE: This review highlights the potential of AI to improve clinical outcomes and operational efficiency in cardiology. By leveraging AI-guided analyses in modalities like ECG, echocardiography, and cardiac CT, clinicians can achieve earlier and more accurate diagnoses, tailor patient management strategies, and potentially reduce hospitalizations and adverse events.
TRANSLATIONAL OUTLOOK: To move from promise to practice, further large-scale, well-designed RCTs are essential to validate AI’s clinical benefits, ensure data quality, and address ethical and privacy considerations. Greater clinician education, standardization of outcome measures, and proactive involvement of hospitals and clinical leaders can foster sustainable integration of AI into routine cardiovascular care, ultimately enhancing patient trust and long-term outcomes.
Declaration of Generative AI and AI-Assisted Technologies in the Writing Process
During the preparation of this work, the authors used ChatGPT for proofreading. After using this tool, the authors reviewed and edited the content as needed and take full responsibility for the publication's content.
Funding support and author disclosures
The authors have reported that they have no relationships relevant to the contents of this paper to disclose.
Footnotes
The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center.
Appendix
For supplemental information and tables, please see the online version of this paper.
Supplementary data
References
- 1.Ito S., Cohen-Shelly M., Attia Z.I., et al. Correlation between artificial intelligence-enabled electrocardiogram and echocardiographic features in aortic stenosis. Eur Heart J Digit Health. 2023;4(3):196–206. doi: 10.1093/ehjdh/ztad009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Galloway C.D., Valys A.V., Shreibati J.B., et al. Development and validation of a deep-learning model to screen for Hyperkalemia from the electrocardiogram. JAMA Cardiol. 2019;4(5):428–436. doi: 10.1001/jamacardio.2019.0640. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Faierstein K., Fiman M., Loutati R., et al. Artificial intelligence assessment of biological age from transthoracic echocardiography: discrepancies with chronologic age predict significant excess mortality. J Am Soc Echocardiogr. 2024;11 doi: 10.1016/j.echo.2024.04.017. [DOI] [PubMed] [Google Scholar]
- 4.Feeny A.K., Chung M.K., Madabhushi A., et al. Artificial intelligence and machine learning in arrhythmias and cardiac electrophysiology. Circ Arrhythm Electrophysiol. 2020;13(8) doi: 10.1161/CIRCEP.119.007952. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Raghunath S., Pfeifer J.M., Ulloa-Cerna A.E., et al. Deep neural networks can predict new-onset atrial fibrillation from the 12-lead ECG and help identify those at risk of atrial fibrillation-related stroke. Circulation. 2021;143(13):1287–1298. doi: 10.1161/CIRCULATIONAHA.120.047829. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Motwani M., Dey D., Berman D.S., et al. Machine learning for prediction of all-cause mortality in patients with suspected coronary artery disease: a 5-year multicentre prospective registry analysis. Eur Heart J. 2017;38(7):500–507. doi: 10.1093/eurheartj/ehw188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Sun X., Yin Y., Yang Q., Huo T. Artificial intelligence in cardiovascular diseases: diagnostic and therapeutic perspectives. Eur J Med Res. 2023;28(1):242. doi: 10.1186/s40001-023-01065-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Hadida Barzilai D., Cohen-Shelly M., Sorin V., et al. Machine learning in cardiac stress test interpretation: a systematic review. Eur Heart J Digit Health. 2024;5(4):401–408. doi: 10.1093/ehjdh/ztae027. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Alowais S.A., Alghamdi S.S., Alsuhebany N., et al. Revolutionizing healthcare: the role of artificial intelligence in clinical practice. BMC Med Educ. 2023;23(1):689. doi: 10.1186/s12909-023-04698-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Gala D., Behl H., Shah M., Makaryus A.N. The role of artificial intelligence in improving patient outcomes and future of healthcare delivery in cardiology: a narrative review of the literature. Healthcare (Basel) 2024;12(4) doi: 10.3390/healthcare12040481. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Han R., Acosta J.N., Shakeri Z., Ioannidis J., Topol E., Rajpurkar P. Randomized controlled trials evaluating AI in clinical practice: a scoping evaluation. medRxiv. 2023;13 doi: 10.1101/2023.09.12.23295381. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kelly B.S., Judge C., Bollard S.M., et al. Radiology artificial intelligence: a systematic review and evaluation of methods (RAISE) Eur Radiol. 2022;32(11):7998–8007. doi: 10.1007/s00330-022-08784-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Beede E., Baylor E., Hersch F., et al. Proceedings of the 2020 CHI Conference on human Factors in computing systems. ACM; 2020. A human-centered evaluation of a deep learning system deployed in clinics for the detection of diabetic retinopathy; pp. 1–12. [DOI] [Google Scholar]
- 14.Elias P., Jain S.S., Poterucha T., et al. Artificial intelligence for cardiovascular care-Part 1: advances: JACC review topic of the week. J Am Coll Cardiol. 2024;83(24):2472–2486. doi: 10.1016/j.jacc.2024.03.400. [DOI] [PubMed] [Google Scholar]
- 15.Plana D., Shung D.L., Grimshaw A.A., Saraf A., Sung J.J.Y., Kann B.H. Randomized clinical trials of machine learning interventions in health care: a systematic review. JAMA Netw Open. 2022;5(9) doi: 10.1001/jamanetworkopen.2022.33946. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Zhou Q., Chen Z.-H., Cao Y.-H., Peng S. Clinical impact and quality of randomized controlled trials involving interventions evaluating artificial intelligence prediction tools: a systematic review. npj Digital Med. 2021;4(1):154. doi: 10.1038/s41746-021-00524-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Moosavi A., Huang S., Vahabi M., et al. Prospective human validation of artificial intelligence interventions in cardiology: a scoping review. JACC: Adv. 2024;3(9) doi: 10.1016/j.jacadv.2024.101202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Jain S.S., Elias P., Poterucha T., et al. Artificial intelligence in cardiovascular care-Part 2: applications: JACC review topic of the week. J Am Coll Cardiol. 2024;83(24):2487–2496. doi: 10.1016/j.jacc.2024.03.401. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Page M.J., Moher D., Bossuyt P.M., et al. PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews. BMJ. 2021;372 doi: 10.1136/bmj.n160. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Revolutionizing Health Care with AI: A new Era of efficiency, trust, and care excellence | NEJM AI sponsored. NEJM AI Sponsored. 2024 [Google Scholar]
- 21.Cruz Rivera S., Liu X., Hughes S.E., et al. Embedding patient-reported outcomes at the heart of artificial intelligence health-care technologies. Lancet Digit Health. 2023;5(3):e168–e173. doi: 10.1016/S2589-7500(22)00252-7. [DOI] [PubMed] [Google Scholar]
- 22.Guni A., Sounderajah V., Whiting P., Bossuyt P., Darzi A., Ashrafian H. Revised tool for the quality assessment of diagnostic accuracy studies using AI (QUADAS-AI): protocol for a qualitative study. JMIR Res Protoc. 2024;13 doi: 10.2196/58202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Sounderajah V., Ashrafian H., Rose S., et al. A quality assessment tool for artificial intelligence-centered diagnostic test accuracy studies: QUADAS-AI. Nat Med. 2021;27(10):1663–1665. doi: 10.1038/s41591-021-01517-0. [DOI] [PubMed] [Google Scholar]
- 24.Lin C.-S., Liu W.-T., Tsai D.-J., et al. AI-enabled electrocardiography alert intervention and all-cause mortality: a pragmatic randomized clinical trial. Nat Med. 2024;30(5):1461–1470. doi: 10.1038/s41591-024-02961-4. [DOI] [PubMed] [Google Scholar]
- 25.Yao X., Rushlow D.R., Inselman J.W., et al. Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial. Nat Med. 2021;27(5):815–819. doi: 10.1038/s41591-021-01335-4. [DOI] [PubMed] [Google Scholar]
- 26.Hill N.R., Groves L., Dickerson C., et al. Identification of undiagnosed atrial fibrillation using a machine learning risk-prediction algorithm and diagnostic testing (PULsE-AI) in primary care: a multi-centre randomized controlled trial in England. Eur Heart J Digit Health. 2022;3(2):195–204. doi: 10.1093/ehjdh/ztac009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Adedinsewo D.A., Morales-Lara A.C., Afolabi B.B., et al. Artificial intelligence guided screening for cardiomyopathies in an obstetric population: a pragmatic randomized clinical trial. Nat Med. 2024;30(10):2897–2906. doi: 10.1038/s41591-024-03243-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Lin C., Liu W.-T., Chang C.-H., et al. Artificial intelligence–powered rapid identification of ST-elevation myocardial infarction via electrocardiogram (ARISE) — a pragmatic randomized controlled trial. NEJM AI. 2024;1(7) doi: 10.1056/AIoa2400190. [DOI] [Google Scholar]
- 29.Huang S., Zhao T., Liu C., et al. Portable device improves the detection of atrial fibrillation after ablation. Int Heart J. 2021;62(4):786–791. doi: 10.1536/ihj.21-067. [DOI] [PubMed] [Google Scholar]
- 30.Yang J., Shan D., Wang X., et al. On-site computed tomography-derived fractional flow Reserve to guide management of patients with stable coronary artery disease: the TARGET randomized trial. Circulation. 2023;147(18):1369–1381. doi: 10.1161/CIRCULATIONAHA.123.063996. [DOI] [PubMed] [Google Scholar]
- 31.Sandhu A.T., Rodriguez F., Ngo S., et al. Incidental coronary artery Calcium: opportunistic screening of previous nongated chest computed tomography scans to improve statin rates (NOTIFY-1 project) Circulation. 2023;147(9):703–714. doi: 10.1161/CIRCULATIONAHA.122.062746. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.De Backer O., Iriart X., Kefer J., et al. Impact of computational modeling on transcatheter left atrial appendage closure efficiency and outcomes. JACC Cardiovasc Interv. 2023;16(6):655–666. doi: 10.1016/j.jcin.2023.01.008. [DOI] [PubMed] [Google Scholar]
- 33.He B., Kwan A.C., Cho J.H., et al. Blinded, randomized trial of sonographer versus AI cardiac function assessment. Nature. 2023;616(7957):520–524. doi: 10.1038/s41586-023-05947-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Upton R., Akerman A.P., Marwick T.H., et al. PROTEUS: a prospective RCT evaluating use of AI in stress echocardiography. NEJM AI. 2024;1(11) doi: 10.1056/AIoa2400865. [DOI] [Google Scholar]
- 35.Liu X., Cruz Rivera S., Moher D., Calvert M.J., Denniston A.K. SPIRIT-AI and CONSORT-AI Working Group. Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension. Nat Med. 2020;26(9):1364–1374. doi: 10.1038/s41591-020-1034-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Cruz Rivera S., Liu X., Chan A.-W., et al. Guidelines for clinical trial protocols for interventions involving artificial intelligence: the SPIRIT-AI extension. Nat Med. 2020;26(9):1351–1363. doi: 10.1038/s41591-020-1037-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Cacciamani G.E., Chu T.N., Sanford D.I., et al. PRISMA AI reporting guidelines for systematic reviews and meta-analyses on AI in healthcare. Nat Med. 2023;29(1):14–15. doi: 10.1038/s41591-022-02139-w. [DOI] [PubMed] [Google Scholar]
- 38.Collins G.S., Dhiman P., Andaur Navarro C.L., et al. Protocol for development of a reporting guideline (TRIPOD-AI) and risk of bias tool (PROBAST-AI) for diagnostic and prognostic prediction model studies based on artificial intelligence. BMJ Open. 2021;11(7) doi: 10.1136/bmjopen-2020-048008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Collins G.S., Moons K.G.M., Dhiman P., et al. TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ. 2024;385 doi: 10.1136/bmj-2023-078378. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Sounderajah V., Ashrafian H., Aggarwal R., et al. Developing specific reporting guidelines for diagnostic accuracy studies assessing AI interventions: the STARD-AI Steering Group. Nat Med. 2020;26(6):807–808. doi: 10.1038/s41591-020-0941-1. [DOI] [PubMed] [Google Scholar]
- 41.Mongan J., Moy L., Kahn C.E. Checklist for artificial intelligence in medical imaging (CLAIM): a guide for authors and reviewers. Radiol Artif Intell. 2020;2(2) doi: 10.1148/ryai.2020200029. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Vasey B., Nagendran M., Campbell B., et al. Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI. BMJ. 2022;377 doi: 10.1136/bmj-2022-070904. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Sengupta P.P., Shrestha S., Berthon B., et al. Proposed requirements for cardiovascular imaging-related machine learning evaluation (PRIME): a checklist: reviewed by the American college of cardiology healthcare Innovation council. JACC Cardiovasc Imaging. 2020;13(9):2017–2035. doi: 10.1016/j.jcmg.2020.07.015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Martindale A.P.L., Llewellyn C.D., de Visser R.O., et al. Concordance of randomised controlled trials for artificial intelligence interventions with the CONSORT-AI reporting guidelines. Nat Commun. 2024;15(1):1619. doi: 10.1038/s41467-024-45355-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Petmezas G., Papageorgiou V.E., Vassilikos V., et al. Recent advancements and applications of deep learning in heart failure: Α systematic review. Comput Biol Med. 2024;176 doi: 10.1016/j.compbiomed.2024.108557. [DOI] [PubMed] [Google Scholar]
- 46.Siranart N., Deepan N., Techasatian W., et al. Diagnostic accuracy of artificial intelligence in detecting left ventricular hypertrophy by electrocardiograph: a systematic review and meta-analysis. Sci Rep. 2024;14(1) doi: 10.1038/s41598-024-66247-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Somani S., Russak A.J., Richter F., et al. Deep learning and the electrocardiogram: review of the current state-of-the-art. Europace. 2021;23(8):1179–1191. doi: 10.1093/europace/euaa377. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Singh S., Chaudhary R., Bliden K.P., et al. Meta-analysis of the performance of AI-driven ECG interpretation in the diagnosis of valvular heart diseases. Am J Cardiol. 2024;213:126–131. doi: 10.1016/j.amjcard.2023.12.015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Sazzad F., Ler A.A.L., Furqan M.S., et al. Harnessing the power of artificial intelligence in predicting all-cause mortality in transcatheter aortic valve replacement: a systematic review and meta-analysis. Front Cardiovasc Med. 2024;11 doi: 10.3389/fcvm.2024.1343210. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Ouyang D., Hogan J. We need more randomized clinical trials of AI. NEJM AI. 2024;1(11) doi: 10.1056/AIe2400881. [DOI] [Google Scholar]
- 51.Youssef A., Pencina M., Thakur A., Zhu T., Clifton D., Shah N.H. External validation of AI models in health should be replaced with recurring local validation. Nat Med. 2023;29(11):2686–2687. doi: 10.1038/s41591-023-02540-z. [DOI] [PubMed] [Google Scholar]
- 52.Han R., Acosta J.N., Shakeri Z., Ioannidis J.P.A., Topol E.J., Rajpurkar P. Randomised controlled trials evaluating artificial intelligence in clinical practice: a scoping review. Lancet Digit Health. 2024;6(5):e367–e373. doi: 10.1016/S2589-7500(24)00047-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Sorin V., Soffer S., Glicksberg B.S., Barash Y., Konen E., Klang E. Adversarial attacks in radiology - a systematic review. Eur J Radiol. 2023;167 doi: 10.1016/j.ejrad.2023.111085. [DOI] [PubMed] [Google Scholar]
- 54.Artificial Intelligence and Machine Learning (AI/ML)-Enabled Medical Devices | FDA. https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-and-machine-learning-aiml-enabled-medical-devices [DOI] [PMC free article] [PubMed]
Associated Data