ABSTRACT
Objective
This study assessed the impact of the method of manufacturing, surface treatment, and thickness on the stainability of zirconia after thermocycling.
Methods
Twenty 0.5 × 10 mm and 20 1 × 10 mm zirconia disks were fabricated using a milling machine. Also, 20 0.5 × 10 mm and 20 1 × 10 mm zirconia disks were fabricated using a 3D printer. After sintering, samples were subjected to one of the two surface treatments (n = 10). Eight study groups were arranged as (1) 0.5 mm printed–polished, (2) 1 mm printed–polished, (3) 0.5 mm printed–glazed, (4) 1 mm printed–glazed, (5) 0.5 mm milled–polished, (6) 1 mm milled–polished, (7) 0.5 mm milled–glazed, and (8) 1 mm milled–glazed. CIELab values were measured with a spectrophotometer before and after 10,000 thermal cycles in coffee solution. ΔE00 readings were compared with perceptibility (< 0.8) and acceptability (< 1.8) thresholds. Data were analyzed using three‐way ANOVA and the Games–Howell test (α = 0.05).
Results
Although all mean ΔE00 values were below the acceptability threshold, only 1 mm printed–glazed zirconia and all milled zirconia samples, except for the 0.5 mm polished group, were below the perceptibility threshold. A significant interaction was found between the production method, surface treatment, and thickness (p = 0.002); 0.5 mm printed zirconia, either polished or glazed, and also 1 mm polished printed zirconia exhibited significantly higher ΔE00 than their milled counterparts. Moreover, glazing significantly reduced stainability in all zirconia specimens (p < 0.05). Also, 1 mm milled–polished zirconia had a lower ΔE00 value than its 0.5 mm counterpart (p = 0.038).
Conclusions
Printed zirconia had less color stability than milled zirconia. Glazing provided the lower color change for both milled and printed zirconia. Thicker milled–polished zirconia had a better color stability.
Clinical Significance
Although the color stainability of printed zirconia was more than milled zirconia, it showed clinically acceptable color change values along with the milled zirconia, regardless of the method of surface treatment and thickness.
Keywords: 3D printing, milling, stainability, thermocycling, zirconia
1. Introduction
Zirconia provides both strength and esthetic appeal, making it desirable in restorative dentistry. Subtractive manufacturing using computer‐aided design/computer‐aided manufacturing (CAD/CAM) technology is the most common method of manufacturing zirconia restorations in dentistry (Khanlar et al. 2021). However, the milling process generates significant material waste and can cause wear on the milling tools, necessitating frequent replacements. Additionally, creating complex structures through milling can be time‐consuming (Khanlar et al. 2021; Methani et al. 2020). Additive manufacturing, also known as three‐dimensional (3D) printing, has been recently introduced for fabricating dental ceramics (Baysal et al. 2022). This technique potentially provides dental restorations with high accuracy, especially in complex and challenging circumstances, and reduced costs (Baysal et al. 2022; Della Bona et al. 2021; Rekow 2020). Furthermore, the even surfaces and fewer undercuts produced by 3D printing decrease the need for considerable post‐production adjustments (Della Bona et al. 2021; Rekow 2020). Various 3D printing methods have been employed to manufacture zirconia restorations, including vat‐photopolymerization method, including stereolithography (SLA), direct light processing (DLP), selective laser sintering (SLS), selective laser melting (SLM), direct inkjet printing (DIP), nanoparticle jetting, binder jetting, fused deposition modeing (FDM), and direct energy deposition (Alghauli et al. 2024). Several factors, such as solid amount, printing parameters, debinding, and sintering temperature, control layer height and printing speeds during additive manufacturing, and could affect the properties of zirconia, such as the amount of porosity (Branco et al. 2020a; Buj‐Corral et al. 2021). Microscopical studies have shown that the surface of 3D‐printed zirconia has micropores due to the weak bonding between the layers, and also air bubbles trapped in the zirconia paste (Branco et al. 2020b; Lu et al. 2020). However, coating the 3D‐printed zirconia with glaze could lead to the absence of pores and a significant reduction of the surface roughness, much like in milled zirconia (Branco et al. 2020b). Compared to stereolithography, DLP provides faster printing speeds due to its ultrarapid light shifting and integral projection capabilities (Ruggiero et al. 2025). Furthermore, DLP can achieve greater resolution by employing multiple micro‐mirrors, and also cures the entire layer at once with a single projection from the light source (Unkovskiy et al. 2021; Al Hamad et al. 2022). Nevertheless, additively manufactured zirconia restorations have shown acceptable precision, trueness, and clinical performance like milled zirconia.
The esthetic success of zirconia restorations depends on many factors, such as shade, translucency, fluorescence, surface texture, and contour (Tabatabaian et al. 2022; Eftekhar Ashtiani et al. 2023; Thalib et al. 2025; Saker and Özcan 2021; Kontonasaki et al. 2019; Walczak et al. 2019; Rigos et al. 2025; Zhu et al. 2024; Reybod et al. 2025; Manziuc et al. 2019; Alp et al. 2018; Ashy et al. 2021). However, color matching and color stability are often perceived as the most esthetic factors for patient satisfaction. Ensuring the restoration's color stability is crucial for the long‐term success of indirect dental treatments (Alghauli et al. 2024; Eftekhar Ashtiani et al. 2023). The stainability of zirconia is determined by a number of parameters, including ceramic manufacturing method, composition, surface characteristics such as surface roughness and porosity, and staining liquids (Tabatabaian et al. 2022; Rigos et al. 2025; Alp et al. 2018; Ashy et al. 2021). Only one recent study assessed the impact of artificial aging on the color stability of a 3D‐printed polished zirconia ceramic after immersion in staining beverages in comparison to milled zirconia and reported color differences for both materials, with less color change for printed zirconia in comparison to milled zirconia (Rigos et al. 2025).
Considering the introduction of 3D‐printed zirconia in dentistry and the lack of studies on the stainability of this material with different surface treatments and different thicknesses in comparison to milled zirconia, the current study was designed to examine the color change of milled and printed zirconia disks following coffee thermocycling. Three null hypotheses were developed as follows: (1) there is no difference in stainability between milled and printed zirconia after coffee thermocycling, (2) there is no difference in stainability between either printed or milled zirconia with two surface treatments of polishing and glazing after coffee thermocycling, and (3) there is no difference in stainability between two thicknesses of 0.5 mm and 1 mm for either polished or milled zirconia after coffee thermocycling.
2. Materials and Methods
According to a previous study and considering α = 0.05, β = 0.2, power = 80%, SD = 0.2, d = 0.25 (Tabatabaian et al. 2022), sample size was calculated using the formula (n = [(Z1 − α/2 + Z1 − β)2 × 2SD2] ÷ d2). Also, considering α = 0.05, β = 0.2, power = 80%, SD = 1.63 & 2.24, effect size = 1.4 (Abounassif et al. 2024), sample size was confirmed using G*Power software. Eighty zirconia disks (10 × 1 mm, 10 × 0.5 mm) were considered (n = 10 per group) (Figure 1), which were digitally designed using Exocad software (Exocad Dental CAD Galway 3.0), and the standard tessellation language (STL) files were exported for both milling and printing methods.
FIGURE 1.

Zirconia disks with different fabrication methods, surface treatments, and thicknesses. Top right: 0.5 mm thickness; top left: 1 mm thickness.
In the milling group (n = 40), a 5‐axis dental milling machine (DWX‐51D, Roland DGA, Irvine, CA) was used to mill the pre‐sintered 3Y‐TZP‐LA monochrome zirconia blocks (Dental Direkt Bio ZX2 MedicalZirconia; Germany) based on the STL files. The zirconia chemical composition consisted of >99% wt ZrO2+ HfO2 + Y2O3, < 6% wt Y2O3, < 0.15% wt Al2O3, and < 1% wt other oxides. After the coloring procedure, the disks were subjected to sintering at a maximum temperature of 1450°C for 9.2 h in a sintering furnace (VITA Vacumat 6000 M; VITA Zahnfabrik GmbH; Germany). The disks were extracted once the furnace temperature dropped below 300°C and allowed to cool down to room temperature. The specimens were then cleaned in an alcoholic solution for 20 min and air‐dried.
In the printing group (n = 40), zirconia slurry containing 85% zirconia by volume (3% molyttria–partially stabilized tetragonal zirconia polycrystals) was used. The zirconia slurry bottle was put on the mixer machine (LD‐3D mixer; NextDent; Netherlands). In accordance with the manufacturing instructions, 2 kg of homogenized slurry was poured into the slurry tank of the 3D printer (AON 3D printer; ZIPRO dentistry; South Korea). The slurry was distributed on the building plate using a leveler. The UV light emitted by the projector selectively cured the slurry according to the prescribed STL data. A layer thickness of 30 μm and layer line orientations of 45° were used to enhance the accuracy (Mou et al. 2024). The specimen remained mounted to the building plate for 30 min following the curing of the final layer to guarantee the thorough elimination of the uncured slurry. Once the printing process was finished, the building plate was immersed in isopropyl alcohol for 10 min to remove any uncured slurry that still adhered to the components. The components were separated from the construction disks by removing the supports affixed to their surfaces with tweezers. The final remnant of the slurry was removed from the green body using a soft brush, followed by the spraying of isopropyl alcohol on the surfaces of the disks. Debinding the organic particles was carried out by subjecting the disks to a furnace (Tiger speed, Tiger, South Korea) set at a maximum temperature of 1100°C for an average duration of 14 h. The disks were then colored and sintered for approximately 3 h at 1500°C with a heating–cooling rate of 300°C.
For the coloring process, all specimens were immersed using non‐metal tweezers in an A2 shade liquid (Aqua Coloring Liquid, Zirkonzahn; Italy) for 5 s and subsequently positioned over a piece of cellulose while compressed air was applied to eliminate the excess liquid. The samples were afterward positioned on a firing tray beneath a drying lamp.
Eight study groups (n = 10) were arranged as: (1) 0.5 mm milled–polished, (2) 0.5 mm milled–glazed, (3) 1 mm milled–polished, (4) 1 mm milled–glazed, (5) 0.5 mm printed–polished, (6) 0.5 mm printed–glazed, (7) 1 mm printed–polished, and (8) 1 mm printed–glazed. One skilled operator applied surface treatments to the specimens. A two‐step procedure was used to polish both surfaces (Rigos et al. 2025) of the disks using a polishing kit (EVE GmbH; Germany) without water. First, a green cup using light pressure (7.5 min) and then an orange cup using light‐to‐medium pressure, with a single directed motion, was applied to each disk (Baysal et al. 2022). In the glazing group, following the manufacturer's instructions, a thin layer of clear liquid glaze (GC initial glaze; Japan) was applied on both sides of all zirconia disks using a micro‐brush. Each disc was placed on a levelled surface to prevent uneven distribution of liquid material before firing each side of the samples. The disks were fired twice in the ceramic furnace (VITA Vacumat 6000 M; VITA Zahnfabrik GmbH; Germany) at 480°–820°. All samples were cleaned in a bath filled with 98% ethanol for 15 min and then stored at 37°C for 24 h and air dried at room temperature. For ease of tracking and categorization, each sample was assigned a unique number, which was engraved on the back. The accurate thickness of the disks was measured using a digital gauge (293 MDC‐MX Lite; Mitutoyo Corp.). Disks with a thickness outside of 0.5 ± 0.02 mm and 1 ± 0.02 mm were excluded.
Commission Internationale de l'Eclairage (CIElab) values including L* (lightness on Y‐axis from 0 to 100), a* (greenness–redness on X‐axis from −60 to +60), and b* (blueness–yellowness on Z‐axis from −60 to +60) were measured at baseline before thermocycling with a dental spectrophotometer (Spectro Shade Micro; MHT dental; Germany) by an experienced and blinded operator. The measurements were repeated three times for each specimen on a standard gray background (Tabatabaian et al. 2022). Before each measurement, the device was carefully calibrated based on the following criteria: a light source configured at 2° × 45° (polarized, telecentric, monochromatic), a recording taken at 0° (polarized, telecentric), a measurement area of approximately 18 × 14 mm with a grid of 640 × 480 points, a digital resoltion of 640 × 480, and an optical resolution of approximately 0.03 × 0.03 mm (Tabatabaian et al. 2022). A putty silicone material (Speedex, Coltene, Altstatten, Switzerland) index was customized to the mouthpiece of the spectrophotometer to equalize the conditions of color measurement for all specimens and to prevent the effect of external lights. The substrates and samples were positioned in the center of the putty index over a standard gray card (Tabatabaian et al. 2022). The spectrophotometer was calibrated with its white and green plates, respectively, as recommended by the manufacturer. All color measurements were performed three times at the center of each sample by the same blinded operator, and the average amount was recorded for each specimen.
Subsequently, the specimens were subjected to 10,000 thermal cycles (5°C−55°C) equivalent to 12 months in the coffee solution (Tabatabaian et al. 2022; Rigos et al. 2025). The transfer and dwell times were 10 and 30 s, respectively; 15 ml of coffee (Single Origin Colombia; Starbucks) was added to 177 ml of water to produce the coffee solution as specified by the manufacturer. The solution was refreshed every 12 h. For color evaluation, the specimens were cleaned to remove coffee residue under running water and then dried on cellulose paper. CIELab values were again measured after thermocycling.
The mean of the recorded values was used to calculate ΔE00 as follows (Luo et al. 2001):
ΔE00 readings were compared to perceptibility (< 0.8) and acceptability (< 1.8) standards for clinical color interpretation (Paravina et al. 2019).
Statistical analysis was conducted using the SPSS software version 26.0 (SPSS Inc., Chicago, IL, USA). The normal distribution of the data was evaluated by the Shapiro–Wilk analysis. Shapiro‐Wilk analysis was used for each group, and it was statistically significant (> 0.05). Considering three variables of method of fabrication (milling vs. printing), thickness (0.5 mm vs. 1 mm), and method of surface treatment (polishing vs. glazing), three‐way ANOVA and Games–Howell were used to compare the mean ΔE00 values of eight study groups. To evaluate the color stability of specimens, 1‐sided 1‐sample t‐test and software (STATA, StataCorp. LLC, Lakeway, Texas) were used to compare the ΔE00 values of different ceramic materials‐thickness‐surface treatment combinations with the perceptibility threshold of ΔE00 = 0.8 and the acceptability threshold of ΔE00 = 1.8 (α = 0.05).
3. Results
The means CIELab and ΔE00 values for the study groups are presented in Figure 2. The production method (milling vs. printing) and surface treatment (polishing vs. glazing) had a significant effect on the color difference. In addition, significant interactions were found between production method and surface treatment, between surface treatment and thickness, and also among production method, surface treatment, and thickness factors (Table 1). The highest and the lowest ΔE00 values belonged to the 0.5 mm printed–polished group and 1 mm milled–glazed group, respectively (Figure 2 and Table 2). Moreover, the color change of all zirconia groups was below the acceptability threshold (< 1.8), while 1 mm printed–glazed zirconia and all milled zirconia, except for the 0.5 mm polished group, showed an unperceivable color change (< 0.8).
FIGURE 2.

Means values of L* (left upper), a* (right upper), b* (left lower), and ΔE00 (right lower) values for study groups before and after coffee thermocycling [P.P; printed–polished, P.G; printed–glazed, M.P; milled–polished, M.G; milled–glazed].
Table 1.
Results of three‐way ANOVA on the effects of manufacturing technique, surface treatment, and thickness.
| Source | Type III sum of squares | Df | Mean square | F | Sig. |
|---|---|---|---|---|---|
| Production | 0.278 | 1 | 0.278 | 5.319 | 0.024 |
| Surface | 8.253 | 1 | 8.253 | 157.822 | 0.000 |
| Thickness | 0.030 | 1 | 0.030 | 0.577 | 0.450 |
| Production × Surface | 3.058 | 1 | 3.058 | 58.484 | 0.000 |
| Production × Thickness | 0.054 | 1 | 0.054 | 1.036 | 0.312 |
| Surface × Thickness | 0.824 | 1 | 0.824 | 15.749 | 0.000 |
| Production × Surface × Thickness | 0.551 | 1 | 0.551 | 10.536 | 0.002 |
Table 2.
Mean values and SD of DE00 of eight study groups (production × surface treatment × thickness), along with statistical comparisons.
| Groups (Number) | Mean (SD) | Significant pair comparison (< 0.05) |
|---|---|---|
| Printed.Polished.0.5 (1) | 1.4488 (0.39515) | 3, 4, 5, 6, 7, 8 |
| Printed.Polished.1 (2) | 1.4250 (0.16317) | 3, 4, 6, 7, 8 |
| Printed.Glazed.0.5 (3) | 0.8156 (0.18099) | 7, 8 |
| Printed.Glazed.1 (4) | 0.5376 (0.13729) | 5 |
| Milled.Polished.0.5 (5) | 1.1578 (0.35915) | 7, 8 |
| Milled.Polished.1 (6) | 0.6980 (0.08546) | 7, 8 |
| Milled.Glazed.0.5 (7) | 0.4286 (0.12213) | — |
| Milled.Glazed.1 (8) | 0.3784 (0.18098) | — |
3.1. Effect of Manufacturing Method
According to two‐pair comparison between 1 mm glazed printed and milled zirconia, there was no significant difference (p = 0.390). However, 1 mm polished printed zirconia had a higher ΔE00 value than 1 mm polished milled zirconia (p < 0.001). Also, the results indicated that 0.5 mm printed zirconia had a higher ΔE00 value than 0.5 mm milled zirconia in both polished and glazed groups (p < 0.05) (Table 3).
Table 3.
Pairwise comparison of mean ΔE00 values between eight study groups.
| Group | Group | Mean difference | Std. error | Sig. |
|---|---|---|---|---|
| Printed.polished.0.5 | Printed.polished.1 | 0.02374 | 0.13519 | 1.000 |
| Printed.glazed.0.5 | 0.63316 | 0.13744 | 0.009 | |
| Printed.glazed.1 | 0.91118 | 0.13228 | < 0.001 | |
| Milled.polished.0.5 | 0.29095 | 0.16886 | 0.004 | |
| Milled.polished.1 | 0.75073 | 0.12785 | 0.003 | |
| Milled.glazed.0.5 | 1.02020 | 0.13079 | < 0.001 | |
| Milled.glazed.1 | 1.07036 | 0.13744 | < 0.001 | |
| Printed.polished.1 | Printed.glazed.0.5 | 0.60942 | 0.07706 | < 0.001 |
| Printed.glazed.1 | 0.88744 | 0.06743 | < 0.001 | |
| Milled.polished.0.5 | 0.26721 | 0.12475 | 0.440 | |
| Milled.polished.1 | 0.72699 | 0.05825 | < 0.001 | |
| Milled.glazed.0.5 | 0.99646 | 0.06445 | < 0.001 | |
| Milled.glazed.1 | 1.04662 | 0.07706 | < 0.001 | |
| Printed.glazed.0.5 | Printed.glazed.1 | 0.27802 | 0.07184 | 0.202 |
| Milled.polished.0.5 | 0.34221 | 0.12718 | 0.207 | |
| Milled.polished.1 | 0.11757 | 0.06329 | 0.598 | |
| Milled.glazed.0.5 | 0.38704 | 0.06905 | 0.001 | |
| Milled.glazed.1 | 0.43720 | 0.08094 | 0.001 | |
| Printed.glazed.1 | Milled.polished.0.5 | 0.62023 | 0.12159 | 0.005 |
| Milled.polished.1 | 0.16045 | 0.05114 | 0.094 | |
| Milled.glazed.0.5 | 0.10902 | 0.05811 | 0.582 | |
| Milled.glazed.1 | 0.15917 | 0.07183 | 0.390 | |
| Milled.polished.0.5 | Milled.polished.1 | 0.45978 | 0.11675 | 0.038 |
| Milled.glazed.0.5 | 0.72925 | 0.11996 | 0.001 | |
| Milled.glazed.1 | 0.77941 | 0.12718 | 0.001 | |
| Milled.polished.1 | Milled.glazed.0.5 | 0.26947 | 0.04714 | 0.001 |
| Milled.glazed.1 | 0.31963 | 0.06329 | 0.004 | |
| Milled.glazed.0.5 | Milled.glazed.1 | 0.05016 | 0.06904 | 0.500 |
3.2. Effect of Surface Treatment
Analysis of the surface treatment procedures indicated that glazed specimens exhibited lower ΔE00 values as compared to polished specimens for both 0.5 mm and 1 mm printed zirconia (p < 0.05). Similarly, 0.5 mm and 1 mm glazed milled zirconia had a lower ΔE00 value as compared to their polished peers (p < 0.05) (Table 3).
3.3. Effect of Thickness
The increase in thickness from 0.05 mm to 1 mm resulted in less color stainability merely in polished milled zirconia (p = 0.038). However, the effect of thickness on the stainability of printed zirconia was not statistically significant for either polished or glazed specimens (p > 0.05) (Table 3).
Moreover, one sample t‐test revealed that half of tested combinations had ΔE00 values beyond the perceptibility threshold of 0.8 (p < 0.05), except for the 1.1−1 mm glazed printed (p = 0.999), 1 mm polished milled (p = 0.997), 0.5 mm glazed milled (p = 1.000), and 1 mm glazed milled (p = 1.000) (Figure 2).
4. Discussion
Considering the recent introduction of printed zirconia and the lack of comprehensive investigation of its optical properties, this study investigated the effect of manufacturing method, thickness, and surface treatment for DLP‐printed zirconia in comparison to milled zirconia. One recent study evaluated the optical stability of printed zirconia after aging in different beverages such as coffee. However, they only used 2‐mm‐thick zirconia, which is a less common thickness for monolithic zirconia. Considering the clinical application of monolithic zirconia, two thicknesses used in this study were 0.5 mm and 1 mm, which could correspond to the average thickness of laminate veneers and full coverage restorations, respectively (Zhu et al. 2024; Reybod et al. 2025). Moreover, the zirconia used in that study was only polished; however, glazing, as a common process for finishing the surface of monolithic zirconia, was also used in the present study. The first null hypothesis was mostly rejected since there was a significant difference in color stability between milled and printed zirconia samples after coffee thermocycling. The second null hypothesis was completely rejected since there was a significant difference in polished and glazed zirconia stainability after coffee thermocycling. Moreover, the third null hypothesis was partially rejected since there was a significant color difference between the two thicknesses of milled polished zirconia after coffee thermocycling. Considering the acceptability and perceptibility thresholds established by Paravina et al. (2019), most groups had clinically acceptable color changes (0.8 < ΔE00 values < 1.8). However, ΔE00 values of 1 mm printed–glazed zirconia and all milled zirconia samples except for the 0.5 mm polished group remained undetectable by the eye (< 0.8).
According to the findings about the effect of manufacturing method, 0.5 mm printed zirconia showed less color stability in comparison to 0.5 mm milled zirconia, which could be related to the higher surface porosity of printed zirconia. Several studies have reported that printed surfaces exhibit more porosity and therefore, greater surface roughness as compared to milled surfaces (Branco et al. 2020b; Ruggiero et al. 2025), which might be attributed to the potential evaporation of the solvent in the slurry on the exposed surface during printing before the addition of the next layer (Osman et al. 2017). Motro et al. (2012) claimed an 83% positive and significant correlation between the Ra‐value and ΔE00. According to Giugliano et al. (2024), milled zirconia has a higher bulk density and fewer porosities in its structure. Method of manufacturing, grain sizes and porosities (Abounassif et al. 2024), and microstructural composition could affect the optical properties of dental restorations (Manziuc et al. 2019; Alp et al. 2018). The method of milling (wet or dry) might also influence the translucency of milled zirconia (Manziuc et al. 2019). The ceramic particles in the slurry can produce light scattering during vat‐polymerization and lead to unwanted overgrowth of structures that would influence the cure depth and begin unpredictable curing in bilateral directions (Subaşı et al. 2018). This occurrence could ultimately alter the microstructure of zirconia and interrupt its interaction with light. The more porous surface and structure of zirconia produced by additive manufacturing, observed in SEM and XRD analyses, could affect the other optical properties of zirconia in comparison to milled zirconia. Regarding the effect of different surface treatments, there was a less significant color change for glazed zirconia specimens regardless of manufacturing technique and thickness. Glazing, which involves adding a thin layer of low‐fusing porcelain to the surface of ceramic, could reduce the stainability by lowering the surface roughness (Kursoglu et al. 2014). Tabatabaian et al. (2022) also evaluated the effect of the surface treatment method on the color stability of high‐translucent milled zirconia after 10,000 coffee thermal cycles. In line with the findings of this study, they found that ΔE00 values for glazed zirconia were below the perceptibility threshold after coffee thermocycling. However, adjusted and polished zirconia demonstrated clinically acceptable, yet perceptible color changes. Another study reported higher color stability in both pre‐colored and extrinsically colored milled–glazed zirconia; however, there was no significant difference between polished and glazed samples (Giugliano et al. 2024). Similar to monolithic zirconia, glazing increased the color stability of zirconia‐reinforced lithium silicate, lithium disilicate, and also lucite‐reinforced glass ceramics after immersion in coffee solution (Alp et al. 2018; Giugliano et al. 2024; Kursoglu et al. 2014).
Concerning the effect of zirconia thickness, there was a significant difference only between 0.5 mm and 1 mm milled–polished zirconia, and thinner specimens had a greater ΔE00 values. Although no other study has evaluated the effect of thickness on the stainability of zirconia with coffee, this finding is in agreement with Thalib et al. (2025) study that reported less color variations and less chromatic shifts in thicker milled zirconia specimens immersed in coloring liquids. However, they used different thicknesses ranging from 1 mm to 2.5 mm. It was revealed that thicker specimens (2.0 mm and 2.5 mm) exhibited superior resistance to color change (lower ΔE values), even following extended immersion and aging time. They also reported that thickness affected color stability more than immersion time. This behavior may be related to Fick's second law of diffusion and the Beer–Lambert law (Thalib et al. 2025; Kontonasaki et al. 2019), which supports the limited penetration depth of coloring liquids and reduced diffusion pathways for ionic migration in thicker zirconia specimens. Thicker zirconia also presents lower translucency due to increased light scattering, which is a positive factor for color masking ability and a negative point for esthetic color matching. Also, it has been demonstrated that depending on the material thickness, different surface finishing and polishing techniques could further influence translucency and color stability of monolithic milled zirconia (Saker and Özcan 2021). Moreover, another study evaluating the color stability of monolithic zirconia, lithium disilicate, and zirconia‐reinforced lithium silicate glass ceramics at thicknesses of 0.5 mm, 0.7 mm, and 1 mm indicated that there was no significant difference among samples with varying thicknesses (Subaşı et al. 2018). However, it is important to note that samples in previous studies underwent fewer thermal cycles compared to the present study (Subaşı et al. 2018; Arif et al. 2019). On the other hand, Alp et al. (2018) revealed that thickness (1 mm, 1.5 mm, and 2 mm) did not affect the color stability of preshaded and externally shaded milled zirconia following 10,000 coffee thermocycling. On the other hand, in a study performed by Manziuc et al. (2019), the color difference observed before and after glazing in milled zirconia with 0.8 mm, 1.5 mm, and 2 mm thicknesses did not follow a consistent pattern. While the 2 mm samples exhibited a smaller color difference compared to the 1.5 mm samples, the 0.8 mm samples displayed the least color difference among all. Additionally, considering the result of studies reporting non‐glazed zirconia samples exhibiting a better color stability as the thickness increased (Thalib et al. 2025; Ashy et al. 2021), it can be assumed that, along with the thickness of samples, the optical interactions of glazing may influence the overall color difference. Based on the findings of this study, it is recommended that milled zirconia with a minimum thickness of 1 mm be used for achieving optimal long‐term color stability. However, there was no significant correlation between specimen thickness and color parameters in printed zirconia, which might reflect the more pronounced influence of the manufacturing method over the thickness. The printed zirconia groups showed a more significant color change in general, and the effect of thickness was less influential for them.
One of the limitations of this study, besides being an in vitro study, which does not completely relate to the oral environment, was the use of one additive method (DLP) for the fabrication of zirconia. Also, only one brand of zirconia, and limited and smaller thicknesses were used. Samples were not cemented with the resin cement, which could also affect the results. In addition, other staining beverages and both pre‐shaded and extrinsically colored zirconia could be used in future studies.
5. Conclusion
Within the limitation of this study, the color stability of monolithic zirconia was significantly impacted by the manufacturing methodology (printing vs. milling), surface treatment method (glazing vs. polishing), and thickness (0.5 and 1 mm); 1 mm polished printed zirconia, and also 0.5 mm printed zirconia had more stainability than their milled zirconia peers. Glazed zirconia exhibited less color alterations compared to the polished zirconia. The effect of increasing thickness from 0.5 mm to 1 mm was significant only in milled–polished zirconia (less stainability). However, all specimens exhibited color changes that were below the clinically acceptable threshold (1.8).
Author Contributions
Soraya Soleimani performed the investigation, collection, and analysis of data. Elaheh Beyabanaki formatted and edited the manuscript and performed the final editing and revision of the manuscript. Kiana Shakeri wrote the original draft. Reza Eftekhar Ashtiani conceptualized and supervised the project. Farhad Tabatabian revised the manuscript.
Ethics Statement
The authors have nothing to report.
Conflicts of Interest
The authors declare no conflicts of interest.
Acknowledgments
The authors have nothing to report.
Soleimani, S. , Beyabanaki E., Shakeri K., Ashtiani R. E., and Tabatabaian F.. 2025. “Stainability of Polished and Glazed Printed Monolithic Zirconia After Coffee Thermocycling.” Clinical and Experimental Dental Research 11. 10.1002/cre2.70246.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
References
- Abounassif, F. M. , Alfaraj A., Gadah T., Yang C. C., Chu T. M. G., and Lin W. S.. 2024. “Color Stability of Precolored and Extrinsically Colored Monolithic Multilayered Polychromatic Zirconia: Effects of Surface Finishing and Aging.” Journal of Prosthodontics, ahead of print, June 23. 10.1111/jopr.13875. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Alghauli, M. , Alqutaibi A. Y., Wille S., and Kern M.. 2024. “3D‐Printed Versus Conventionally Milled Zirconia for Dental Clinical Applications: Trueness, Precision, Accuracy, Biological and Esthetic Aspects.” Journal of Dentistry 144: 104925. 10.1016/j.jdent.2024.104925. [DOI] [PubMed] [Google Scholar]
- Al Hamad, K. Q. , Al‐Rashdan B. A., Ayyad J. Q., et al. 2022. “Additive Manufacturing of Dental Ceramics: A Systematic Review and Meta‐Analysis.” Journal of Prosthodontics 31, no. 8: e67–e86. 10.1111/jopr.13553. [DOI] [PubMed] [Google Scholar]
- Alp, G. , Subasi M. G., Johnston W. M., and Yilmaz B.. 2018. “Effect of Surface Treatments and Coffee Thermocycling on the Color and Translucency of CAD‐CAM Monolithic Glass‐Ceramic.” Journal of Prosthetic Dentistry 120, no. 2: 263–268. 10.1016/j.prosdent.2017.10.024. [DOI] [PubMed] [Google Scholar]
- Arif, R. , Yilmaz B., and Johnston W. M.. 2019. “In Vitro Colorstainability and Relative Translucency of CAD‐CAM Restorative Materials Used for Laminate Veneers and Complete Crowns.” Journal of Prosthetic Dentistry 122, no. 2: 160–166. 10.1016/j.prosdent.2018.09.011. [DOI] [PubMed] [Google Scholar]
- Ashy, L. M. , Al‐Mutairi A., Al‐Otaibi T., and Al‐Turki L.. 2021. “The Effect of Thermocyclic Aging on Color Stability of High Translucency Monolithic Lithium Disilicate and Zirconia Ceramics Luted With Different Resin Cements: An In Vitro Study.” BMC Oral Health 21, no. 1 (November): 587. 10.1186/s12903-021-01963-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Baysal, N. , TuğbaKalyoncuoğlu Ü., and Ayyıldız S.. 2022. “Mechanical Properties and Bond Strength of Additively Manufactured and Milled Dental Zirconia: A Pilot Study.” Journal of Prosthodontics 31, no. 7: 629–634. 10.1111/jopr.13472. [DOI] [PubMed] [Google Scholar]
- Branco, A. C. , Silva R., Jorge H., et al. 2020a. “Tribological Performance of the Pair Human Teeth vs 3D Printed Zirconia: An In Vitro Chewing Simulation Study.” Journal of the Mechanical Behavior of Biomedical Materials 110: 103900. 10.1016/j.jmbbm.2023.106041 [DOI] [PubMed] [Google Scholar]; Erratum in: Journal of the Mechanical Behavior of Biomedical Materials. 2023 Nov;147:106041. 10.1016/j.jmbbm.2020.103900. [DOI] [PubMed]
- Branco, A.C. , Silva R., and Santos T., et al. 2020b. “Suitability of 3D Printed Pieces of Nanocrystalline Zirconia for Dental Applications.” Dental Materials 36, no. 3: 442–455. 10.1016/j.dental.2020.01.006 [DOI] [PubMed] [Google Scholar]; Erratum in: Dental Materials 2023 Sep;39(9):861. 10.1016/j.dental.2023.08.002. [DOI] [PubMed]
- Buj‐Corral, I. , Vidal D., Tejo‐Otero A., Padilla J. A., Xuriguera E., and Fenollosa‐Artés F.. 2021. “Characterization of 3D Printed Yttria‐Stabilized Zirconia Parts for Use in Prostheses.” Nanomaterials 11, no. 11: 2942. 10.3390/nano11112942. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Della Bona, A. , Cantelli V., Britto V. T., Collares K. F., and Stansbury J. W.. 2021. “3D Printing Restorative Materials Using a Stereolithographic Technique: A Systematic Review.” Dental Materials 37, no. 2: 336–350. 10.1016/j.dental.2020.11.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Eftekhar Ashtiani, R. , Beyabanaki E., Razmgah M., Salazar A., Revilla‐León M., and Zandinejad A.. 2023. “Color Stability of Resin Hybrid Ceramic Materials in Comparison to Zirconia‐Reinforced Lithium Silicate Ceramic.” Frontiers in Dentistry 20: 37. 10.18502/fid.v20i37.13742. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Giugliano, T. S. , Zhang Y., Janal M. N., Lim C. H., Smith R. M., and Choi M.. 2024. “In Vitro Comparison of Physical Characteristics of Milled Versus Printed Zirconia Discs.” Journal of Prosthodontics 33, no. 9: 891–898. 10.1111/jopr.13778. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Khanlar, L. N. , Salazar Rios A., Tahmaseb A., and Zandinejad A.. 2021. “Additive Manufacturing of Zirconia Ceramic and Its Application in Clinical Dentistry: A Review.” Dentistry Journal 9, no. 9: 104. 10.3390/dj9090104. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kontonasaki, E. , Rigos A. E., Ilia C., and Istantsos T.. 2019. “Monolithic Zirconia: An Update to Current Knowledge. Optical Properties, Wear, and Clinical Performance.” Dentistry Journal (Basel) 7, no. 3: 90. 10.3390/dj7030090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kursoglu, P. , KaragozMotro P. F., and Kazazoglu E.. 2014. “Correlation of Surface Texture With the Stainability of Ceramics.” Journal of Prosthetic Dentistry 112, no. 2: 306–313. 10.1016/j.prosdent.2013.09.028. [DOI] [PubMed] [Google Scholar]
- Lu, Y. , Mei Z., Zhang J., et al. 2020. “Flexural Strength and Weibull Analysis of Y‐TZP Fabricated by Stereolithographic Additive Manufacturing and Subtractive Manufacturing.” Journal of the European Ceramic Society 40, no. 3: 826–834. 10.1016/j.jeurceramsoc.2019.10.058. [DOI] [Google Scholar]
- Luo, M. R. , Cui G., and Rigg B.. 2001. “The Development of the CIE 2000 Colour Difference Formula: CIEDE2000.” Color Research & Application 26, no. 5: 340–350. 10.1002/col.1049. [DOI] [Google Scholar]
- Manziuc, M. M. , Gasparik C., Burde A. V., Colosi H. A., Negucioiu M., and Dudea D.. 2019. “Effect of Glazing on Translucency, Color, and Surface Roughness of Monolithic Zirconia Materials.” Journal of Esthetic and Restorative Dentistry 31, no. 5: 478–485. 10.1111/jerd.12493. [DOI] [PubMed] [Google Scholar]
- Methani, M. M. , Revilla‐León M., and Zandinejad A.. 2020. “The Potential of Additive Manufacturing Technologies and Their Processing Parameters for the Fabrication of All‐Ceramic Crowns: A Review.” Journal of Esthetic and Restorative Dentistry 32, no. 2: 182–192. 10.1111/jerd.12535. [DOI] [PubMed] [Google Scholar]
- Motro, P. F. K. , Kursoglu P., and Kazazoglu E.. 2012. “Effects of Different Surface Treatments on Stainability of Ceramics.” Journal of Prosthetic Dentistry 108, no. 4: 231–237. 10.1016/S0022-3913(12)60168-1. [DOI] [PubMed] [Google Scholar]
- Mou, Z. , Zhong J., Wang F., et al. 2024. “Zirconia Crowns Manufactured Using Digital Light Processing: Effects of Build Angle and Layer Thickness on the Accuracy.” Journal of Dentistry 151: 105359. 10.1016/j.jdent.2024.105359. [DOI] [PubMed] [Google Scholar]
- Osman, R. B. , van der Veen A. J., Huiberts D., Wismeijer D., and Alharbi N.. 2017. “3D‐printing Zirconia Implants; A Dream or a Reality? An In‐Vitro Study Evaluating the Dimensional Accuracy, Surface Topography and Mechanical Properties of Printed Zirconia Implant and Discs.” Journal of the Mechanical Behavior of Biomedical Materials 75: 521–528. 10.1016/j.jmbbm.2017.08.018. [DOI] [PubMed] [Google Scholar]
- Paravina, R. D. , Pérez M. M., and Ghinea R.. 2019. “Acceptability and Perceptibility Thresholds in Dentistry: A Comprehensive Review of Clinical and Research Applications.” Journal of Esthetic and Restorative Dentistry 31, no. 2: 103–112. 10.1111/jerd.12465. [DOI] [PubMed] [Google Scholar]
- Rekow, E. D. 2020. “Digital Dentistry: The New State of the Art—Is It Disruptive or Destructive?” Dental Materials 36, no. 1: 9–24. 10.1016/j.dental.2019.08.103. [DOI] [PubMed] [Google Scholar]
- Reybod, S. , Ezoji F., Ahmadizenouz G., and Esmaeili B.. 2025. “Investigating the Ability to Mask Dental Discoloration by CAD/CAM Bleach Shade Ceramics in Different Thicknesses.” Clinical and Experimental Dental Research 11, no. 1: e70102. 10.1002/cre2.70102. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rigos, A. E. , Kesterke M. J., Chen J. H., Kontonasaki E., and Kontogiorgos E. D.. 2025. “Optical Stability of 3D‐printed and Milled Zirconia After Artificial Aging and Immersion in Liquids: An In Vitro Study.” Journal of Prosthodontics, ahead of print. 10.1111/jopr.14090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ruggiero, M. M. , Souza L. V. S., Magno M. B., et al. 2025. “Is Additive Manufacturing of Dental Zirconia Comparable to Subtractive Methods When Considering Printing Orientation and Layer Thickness? A Systematic Review and Meta‐Analysis.” Journal of Esthetic and Restorative Dentistry, ahead of print. 10.1111/jerd.13514. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Saker, S. , and Özcan M.. 2021. “Effect of Surface Finishing and Polishing Procedures on Color Properties and Translucency of Monolithic Zirconia Restorations at Varying Thickness.” Journal of Esthetic and Restorative Dentistry 33, no. 6: 953–963. 10.1111/jerd.12681. [DOI] [PubMed] [Google Scholar]
- Subaşı, M. G. , Alp G., Johnston W. M., and Yilmaz B.. 2018. “Effect of Thickness on Optical Properties of Monolithic CAD‐CAM Ceramics.” Journal of Dentistry 71: 38–42. 10.1016/j.jdent.2018.01.010. [DOI] [PubMed] [Google Scholar]
- Tabatabaian, F. , Vali S., and Namdari M.. 2022. “Effect of Surface Treatment and Surface Region on the Colorstainability of a Cemented High‐Translucency Monolithic Zirconia Ceramic After Coffee Thermocycling.” Journal of Prosthetic Dentistry 127, no. 5: 767.e1–767.e7. 10.1016/j.prosdent.2022.01.032. [DOI] [PubMed] [Google Scholar]
- Thalib, A. M. , Gumilar K. E., Israyani I., et al. 2025. “Effect of Ion Release on Color Stability of Zirconia: A Comparative Study.” Applied Sciences 15, no. 11: 6364. 10.3390/app15116364. [DOI] [Google Scholar]
- Unkovskiy, A. , Schmidt F., Beuer F., Li P., Spintzyk S., and Kraemer Fernandez P.. 2021. “Stereolithography vs. Direct Light Processing for Rapid Manufacturing of Complete Denture Bases: An In Vitro Accuracy Analysis.” Journal of Clinical Medicine 10, no. 5: 1070. 10.3390/jcm10051070. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Walczak, K. , Meißner H., Range U., et al. 2019. “Translucency of Zirconia Ceramics Before and After Artificial Aging.” Journal of Prosthodontics 28, no. 1: e319–e324. 10.1111/jopr.12771. [DOI] [PubMed] [Google Scholar]
- Zhu, Z. , Huang X., Lyu J., Yang X., Tan J., and Liu X.. 2024. “Optical Properties of Monolithic Zirconia Fabricated With Nanoparticle Jetting.” Journal of Prosthetic Dentistry 132, no. 2: 464.e1–464.e8. 10.1016/j.prosdent.2024.05.005. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
