Skip to main content
Zeitschrift für Medizinische Physik logoLink to Zeitschrift für Medizinische Physik
. 2023 Aug 18;35(3):235–247. doi: 10.1016/j.zemedi.2023.07.007

Radiation-induced double-strand breaks by internal ex vivo irradiation of lymphocytes: Validation of a Monte Carlo simulation model using GATE and Geant4-DNA

Maikol Salas-Ramirez a,⁎, Lydia Maigne b, Giovanna Fois b, Harry Scherthan c, Michael Lassmann a, Uta Eberlein a
PMCID: PMC12664439  PMID: 37599196

Abstract

This study describes a method to validate a radiation transport model that quantifies the number of DNA double-strand breaks (DSB) produced in the lymphocyte nucleus by internal ex vivo irradiation of whole blood with the radionuclides 90Y, 99mTc, 123I, 131I, 177Lu, 223Ra, and 225Ac in a test vial using the GATE/Geant4 code at the macroscopic level and the Geant4-DNA code at the microscopic level.

Methods

The simulation at the macroscopic level reproduces an 8 mL cylindrical water-equivalent medium contained in a vial that mimics the geometry for internal ex vivo blood irradiation. The lymphocytes were simulated as spheres of 3.75 µm radius randomly distributed, with a concentration of 125 spheres/mL. A phase-space actor was attached to each sphere to register all the entering particles. The simulation at the microscopic level for each radionuclide was performed using the Geant4-DNA tool kit, which includes the clustering example centered on a density-based spatial clustering of applications with noise (DBSCAN) algorithm. The irradiation source was constructed by generating a single phase space from the sum of all phase spaces. The lymphocyte nucleus was defined as a water sphere of a 3.1 µm radius. The absorbed dose coefficients for lymphocyte nuclei (dLymph) were calculated and compared with macroscopic whole blood absorbed dose coefficients (dBlood). The DBSCAN algorithm was used to calculate the number of DSBs. Lastly, the number of DSB∙cell−1∙mGy−1 (simulation) was compared with the number of radiation-induced foci per cell and absorbed dose (RIF∙cell−1∙mGy−1) provided by experimental data for gamma and beta emitting radionuclides. For alpha emitters, dLymph and the number of α-tracks∙100 cell−1∙mGy−1 and DSBs∙µm−1 were calculated using experiment-based thresholds for the α-track lengths and DSBs/track values. The results were compared with the results of an ex vivo study with 223Ra.

Results

The dLymph values differed from the dBlood values by −1.0% (90Y), −5.2% (99mTc), −22.3% (123I), 0.35% (131I), 2.4% (177Lu), −5.6% (223Ra) and −6.1% (225Ac). The number of DSB∙cell−1∙mGy−1 for each radionuclide was 0.014 DSB∙cell−1∙mGy−1 (90Y), 0.016 DSB∙cell−1∙mGy−1 (99mTc), 0.013 DSB∙cell−1∙mGy−1 (123I), 0.012 DSB∙cell−1∙mGy−1 (131I), and 0.012 DSB∙cell−1∙mGy−1 (177Lu). These values agree very well with experimental data. The number of α-tracks∙100 cells−1∙mGy−1 for 223Ra and 225Ac where 0.144 α-tracks∙100 cells−1∙mGy−1 and 0.151 α-tracks∙100 cells−1∙mGy−1, respectively. These values agree very well with experimental data. Moreover, the linear density of DSBs per micrometer α-track length were 11.13 ± 0.04 DSB/µm and 10.86 ± 0.06 DSB/µm for 223Ra and 225Ac, respectively.

Conclusion

This study describes a model to simulate the DNA DSB damage in lymphocyte nuclei validated by experimental data obtained from internal ex vivo blood irradiation with radionuclides frequently used in diagnostic and therapeutic procedures in nuclear medicine.

Keywords: Monte Carlo simulation, Geant4-DNA, GATE, Blood dosimetry, DNA damage

Introduction

The simulation of DNA damage using Monte Carlo track structure codes has proven to help expand the understanding of how ionizing radiation (IR) interacts with the DNA, specifically in simulating DNA single- and double-strand breaks (SSBs and DSBs) [1], [2]. The main advantage of Monte Carlo track structure simulations is registering the spatial distribution of interactions of IR with DNA and quantifying the amount of deposited energy in each interaction [3]. The simulation of radiation-induced DNA SSBs and DSBs using Monte Carlo track structure codes is performed mainly in two different techniques: 1) By the interaction of IR with the three-dimensional structure of a DNA molecule [3] or by using clustering algorithms based on the identification of DNA strand breaks according to the spatial distribution of interactions of IR with a water medium [4], [5]. In both cases, it is necessary to apply predefined parameters (e.g., deposited energy thresholds and distance between interactions) to assess the DNA damage probability [6]. Moreover, other processes (e.g., physicochemical and chemical) can be considered after the interactions of IR with a cellular nucleus.

Beyond the Monte Carlo simulation, validating the simulation model with experimental data is fundamental [1]. The response of the DNA molecule to the IR-induced damage, specifically the production of γ-H2AX and 53BP1 radiation-induced foci (RIF) indicative of DSBs [7], is the counterpart to Monte Carlo simulated DNA DSB [2]. For an ideal validation of the Monte Carlo Simulation a 1:1 correspondence between RIF and DSB is needed. This condition is partially achieved at low radiation absorbed doses, where RIF saturation (number of RIF is smaller than the number of DSBs) is less likely to occur [8]. Moreover, various factors such as cellular repair mechanisms, RIF detectability at early time points after irradiation, accessibility of repair proteins at the DSB site, and the bystander effect can still affect and may alter correspondence of RIF and DSB [7].

The present study describes a method for validating a Monte Carlo track structure model based on a clustering algorithm that quantifies the number of DSBs produced in the lymphocyte nucleus after internal ex vivo irradiation of whole blood in a test tube with 90Y, 99mTc, 123I, 131I, and 177Lu using GATE [9], [10] at the macroscopic level and Geant4-DNA [11], [12], [13] codes at the microscopic level. The validation is performed with experimental data in the range of low absorbed doses to the blood frequently encountered in nuclear medicine settings [14], [15], [16], [17], [18]. Moreover, a cluster analysis is implemented to establish the first data set of the number of clusters vs. cluster size (number of strand breaks) for internal ex vivo irradiation with radionuclides used in nuclear medicine.

Materials and methods

This study simulates the blood irradiation experiments performed by Eberlein et al. [14], Schumann [17], and Göring et al. [15]. A description of these experiments is provided in the Supplemental data.

This study is based on two simulation steps. First, a radiation transport at a macroscopic level using GATE was performed. The simulation geometry reproduces the irradiation geometry of a blood sample in an 8 mL vial with a screw cap (Sarstedt, No. 60.542.007, Germany) (Fig. 1A). Seven different radionuclide sources (90Y, 99mTc, 123I, 131I, 177Lu, 223Ra, and 225Ac) were simulated. A detailed description of the simulation at the macroscopic level has been documented previously [19]. In comparison with our previous study, a geometric model of lymphocytes was added to the simulation.

Figure 1.

Figure 1

The layout of the simulation space in GATE: A) Macroscopic geometry: whole blood (8 mL vial) [19]. B) Macroscopic geometry, including the lymphocyte model.

The second step of this study consisted in quantifying the absorbed dose coefficients for lymphocytes’ nuclei per milliliter of blood (dLymph) for 1 h of internal ex vivo irradiation of whole blood with different radionuclides and the number of radiation-induced DSBs, using Geant4-DNA, a setup that has been followed experimentally before [19].

The simulations were performed using GATE version 9.1 installed in combination with Geant4 version 10.7. Geant4-DNA simulations were also performed with the Geant4 version 10.7.

Geometric model of lymphocytes

First, a lymphocyte was defined as a sphere with a radius of 3.75 μm and a nucleus of 3.1 μm. These values are mean values and were obtained from a specialized light microscopy experiment [20]. Next, using a python code, 1000 spheres of 3.75 μm radius [20] were used to mimic lymphocytes and distributed randomly inside of a cylindrical volume of 8 mL (0.72 mm radius and 49.12 mm height [19], avoiding overlapping (Fig. 1B). The coordinates of each sphere were recorded and stored in an external text file (TFile1). Moreover, a second text file (TFile2) with the corresponding GATE scripts to construct the 1000 spheres composed of water with their respective coordinates and spatial translations was generated. Each sphere was defined as an independent logic volume and randomly located inside of the 8 mL vial volume.

Simulation at the macroscopic level using GATE

First, the geometric model of lymphocytes was included in the GATE geometry using the TFile2. The 1000 spheres were defined as cold sources (primary events inside of the spheres were forbidden), and a phase space actor was attached to each sphere [19] (the task of the phase space actor is to record the type, energy, direction, and hit position of each particle that hit the surface of each of the 1000 spheres). The number of primary events (nuclear transformations, nt) in GATE simulation varies according to the radionuclide to achieve a relative uncertainty of less than 5% in the mean deposited energy of the lymphocyte nucleus in the Monte Carlo simulation at the microscopic level (EDeposited,Lymph): 2 × 109 nt for 90Y, 8 × 109 nt for 99mTc, 8 × 109 nt for 123I, 4 × 109 nt for 131I, 4 × 109 nt for 177Lu, 2 × 109 nt for 223Ra, and 2 × 109 nt for 225Ac. The respective output of this first simulation was the phase spaces of the 1000 lymphocytes (1000 spheres of 3.75 μm radius).

Simulation at the microscopic level using Geant4-DNA

The 1000 phase spaces were analyzed with a python code. First, each phase space was read and transformed into a database. Next, the coordinate system of each phase space was translated to the origin ((x,y,z) = (0,0,0)) using the coordinates file generated with the geometric model of lymphocytes (Fig. 2). Subsequently, all the databases were summed and converted into a single database (or total phase space). To reduce the size of the database, all the anti-neutrinos produced by the beta decay in all the simulated radionuclides were removed. Specific information for each particle in the database was selected (e.g., name, weight, kinetic energy, position, direction, event ID) and stored in a file h5 (HDF5) format. Subsequently, the total phase space was used as a source by Geant4-DNA inside the clustering example [4]. To read the h5 file and use it as a source, a new Geant4/C++ class was used. This C++ class was developed at the Laboratoire de Physique de Clermont (University Clermont Auvergne, France).

Figure 2.

Figure 2

The layout of the simulation space: From macroscopic geometry (GATE) to microscopic geometry (cellular level) in Geant4-DNA.

The simulation at the microscopic level does not consider radionuclide internalization or membrane binding. To our knowledge, there is no evidence of these scenarios in lymphocyte irradiation experiments with dissolved radionuclides. Moreover, in the experimental procedure (Supplemental data), the remaining activity after washing was always below 0.2%.

Lastly, to run the simulation, some changes in the de DetectorConstructor, RunAction, EventAction, and StepingAction classes of the clustering example were applied. These classes were added in the Supplemental file. The SteppingAction class was included for 177Lu and 223Ra to provide access to the implemented track length function for alpha particles.

DetectorConstruction class

The simulation space was composed of three volumes: 1) World: Sphere of 3.76 μm radius filled with the G4_Galactic material. The World excess in 0.01 μm the Cell radius to allow for phase space positioning. 2) Cell: Sphere of 3.75 μm radius [20] located at the isocenter of the World volume and filled with the G4_Water material. 3) Nucleus: Sphere of 3.1 μm radius [20] located at the isocenter of the Cell volume and filled with the G4_Water material. Furthermore, the nucleus volume was defined as a scoring volume for calculating the deposited energy and the outputs of the clustering algorithm.

RunAction and EventAction class

To extract the results of the clustering algorithm as a database, the number of single-strand breaks (SSBs), complex SSBs (defined as 2 SSBs or more), DSBs, deposited energy per particle, absorbed dose per particle, and distribution of cluster sizes per particle were saved as tuples into a root file. This root file was read with a python code, which attached the outputs of the clustering algorithm to the total phase space. This allowed correlating the particle type with each of the results of the clustering algorithm. This last general database will be called the complete database to explain future data processing steps.

SteppingAction class

A C++ conditional operator that considers only the interaction inside the nucleus volume was inserted into the SteppingAction class. This restricted the calculations of the clustering algorithm and the scoring of the deposited energy to the nucleus volume.

Moreover, to calculate the length of the alpha track (223Ra and 225Ac), a conditional operator, which selects only alpha particles, was included in the C++ code. In addition, the length of each step was recorded, and a total alpha track length was calculated. The total alpha track length was added to the output root file.

Physics list

The physics list of the dnaphysics example [12], [13] was used instead of the physics list of the clustering example. The physics processes were simulated using the physics list G4EmDNAPhysics_option4 in combination with the G4EmDNAPhysicsActivator. This approach permitted radiation transport of electrons above 10 keV (upper limit of the physics list G4EmDNAPhysics_option4). For radionuclide beta and gamma emitter, the lowest limit of secondary electron production (G4ProductionCutsTable) was adjusted to obtain the lowest difference between the lymphocyte nucleus mean deposited energy (EDeposited,Lymph) and the deposited energy in the blood (EDeposited,Blood) (data taken from publication [19].

Scoring of deposited energy:

At the microscopic level (using Geant4-DNA), the total deposited energy in the nucleus per particle was scored inside the clustering example, extracted, and stored in the complete database. Using a python code, the energy deposited in the lymphocyte nucleus per nuclear transformation was calculated from the total database using the following definition:

EDeposited,LymphkeVnt=∑inEiNCells∙nt=totaldepositedenergyNCells∙nt (1)

nt(nuclear transformations) is the number of simulated events in the GATE simulation. Ei is the energy deposited by the particle i of the total phase space. NCells is equal to 1000; it corresponds to the number of lymphocytes (spheres) in the vial. The uncertainty of EDeposited,Lymph using a history-by-history method was calculated by the expression:

SEDeposited,LymphkeVnt=1NCells1N-1∑inEi2N-∑inEiN2 (2)

Calculation of the dose coefficient for lymphocyte nucleus in 1 mL of blood (dLymph) during 1 h of internal ex vivo irradiation of whole blood

The calculation of dLymph followed the same approach as described previously [19], using a mass of 1.24·10−13 kg (mass of the nucleus). Lastly, the dLymph were compared with whole blood absorbed dose coefficients (dBlood) [19].

Clustering algorithm

The clustering example included in Geant4-DNA code is based on a density-based spatial clustering of applications with noise (DBSCAN) algorithm [4], which was parameterized to simulate the DNA as a water-equivalent unstructured and randomly distributed sensitive volume of 7% volume fraction (SPointsProb: volume occupied by the DNA or sensitive volume in the lymphocyte nucleus). In this study, the 7% SPointsProb value is obtained by the ratio of the DNA volume of 8.3 µm3 (cylinder of 1.1 × 10−9 m radius [21] and a length of 2.2 m (0.34 × 10−9 m/bp [21] × 6.4 × 109 bp [22] and the volume of the lymphocyte nucleus of 124.8 µm3 (sphere of 3.1 × 10−6 m radius). A single-strand break (SSB) is defined as a particle interaction inside of the 7% DNA volume fraction with 0% damage probability for energies below 5 eV (EMinDamage) increasing linearly to 100% at 37.5 eV (EMaxDamage) and above. The damage probability [4] function in the clustering example follows the next selection criteria:

Damageprobability(0<X≤1)=EDeposited,particle-EMinDamageEMaxDamage-EMinDamage (3)

here EDeposited,particle is the energy deposited by a particle inside of the sensitive volume. An interaction is included in the algorithm if X>a, where a is a randomly generated number from a uniform distribution.

Lastly, a DSB is defined as two (MinPts) SSBs separated by less than 10 base pairs (∼3.4 nm).

Quantification of the number of DSBs

The total number of DSBs was extracted from the complete database using a python code to correlate the number of DSBs with the number of radiation-induced foci per cell and absorbed dose (RIFExp(RIF∙cell−1∙mGy−1)) provided by experimental data. First, the activity associate to the number of simulated events (nt) was obtained from the equation:

AMBq=ntN1hntBq∙106BqMBq (4)

Here N1h is the number of nuclear transformations occurring during 1 h of blood irradiation [19].

Second, the absorbed dose to the whole blood (DAbsorbed,Blood) was calculated using the absorbed dose coefficient (dBlood) from [19]:

DAbsorbed,BloodmGy=A[MBq]∙dBloodmGy∙mLMBq8[mL] (5)

Here, dBlood is the whole blood absorbed dose coefficient in an 8 mL vial (water-equivalent medium).

Lastly, to obtain the number of DSB per cell and absorbed dose (DSBMC(DSB∙cell−1∙mGy−1)), the number of DSB per cell is divided by the absorbed dose to the whole blood:

DSBMC=DSBNCells∙DAbsorbed,BloodmGy (6)

Furthermore, the uncertainty associated with DSBMC was calculated by the standard deviation of five Geant4-DNA simulations with different seeds. Lastly, the simulated data (DSBMC) was compared with experimental data (RIFExp) from previous publications [14], [17].

Quantification of the number of alpha tracks (α-track)

Experimentally, the visually counted number of α-tracks is used as a radiobiological marker for alpha emitting radionuclides [15], [16], [23]. Therefore, the total number of alpha particles and their track length were extracted from the complete database. An equivalent procedure to the DSBs calculation (section 6) was applied to determine the number of α-track per cell and absorbed dose (α-trackMC(α-track ∙100 cells−1∙mGy−1)). Furthermore, the uncertainty associated with α-trackMC was calculated by the standard deviation of five Geant4-DNA simulations with different seeds. Additionally, a second value of the number of α-trackMC,Treshold(α-track∙100 cells−1∙mGy−1), was calculated using experimental-based thresholds (α-tracks with a track length superior to 0.75 μm and more than 7 DSBs). Considering a resolution limit of 250–300 nm for a RIF, an alpha track must have at least three adjacent foci in a row. Therefore, the shortest tracks should be between 0.75–0.9 µm. For validation, the simulated data (α-trackMC) with and without threshold were compared with experimental data (α-trackExp) from a previous publication of our group [15].

Lastly, the linear density of DSBs per α-track length (DSBMC,α-track(DSB∙µm−1)) was calculated by considering the total number of DSBs per cell and the α-track length per cell (information extracted from the .root data file. Section: 3.3. SteppingAction class).

Cluster analysis

The number of clusters and the cluster size (number of strand breaks) for each particle in the phase space were extracted from the clustering example and integrated into the complete database. This step made it possible to organize the number of clusters per cell and absorbed dose classified by the number of strand breaks in a histogram. Moreover, by selecting only the particles that produced DSBs (number of DSBs larger than 0 DSBs), a histogram of the number of clusters per cell and absorbed dose with simple DSBs and complex DSBs (defined as 3 SSBs or more, with at least 1 SSB on the opposite chain) was generated.

Results

Comparison between the dose coefficient for lymphocyte nucleus and dose coefficient for whole blood

This section presents a comparison between the dose coefficient for lymphocyte nucleus in 1 mL of blood (dLymph) under 1 h of internal ex vivo irradiation of whole blood and the dose coefficient for whole blood in 1 mL of blood (dBlood) under 1 h of internal ex vivo irradiation reported in a previous publication [19]. Fig. 3 shows the respective dose coefficients for the simulated radionuclide: Fig. 3A presents a plot with the value for beta and gamma emitters, and Fig. 3B for alpha emitters. The dLymph values are reported in Table 1 of the Supplemental material. In the case of beta and gamma emitters, the relatives errors between dLymph and dBlood ranged from −24.8% for 123I to 0.8% for 131I, while for alpha emitters, the relative errors were −5.6% for 223Ra and −6.1% for 225Ac. All the relative errors are plotted in Fig. 3C. For radionuclide beta and gamma emitters, the lowest limit for secondary electron production (G4ProductionCutsTable) were 105 eV for 99mTc, 79 eV for 123I, 105 eV for 131I, 105 eV for 177Lu, and 350 eV for 90Y.

Figure 3.

Figure 3

Absorbed dose coefficients for lymphocytes (dLymph) using Geant4-DNA and whole blood (dBlood) using GATE [19]: A) Values for beta- and gamma-emitters. B) Values for alpha emitters. C) Relative error between dLymph and dBlood (reference: dBlood).

Lastly, the electron, gamma, and alpha input spectra (particles in the phase space) for each radionuclide and a plot of energy deposition vs. kinetic energy are included in Figs. 1–7 of the Supplemental material.

Comparison between the number of DSBs and RIF for radionuclide beta and gamma emitters.

Fig. 4 illustrates the number of DSB per cell and absorbed dose (DSBMC) obtained from the Geant4-DNA simulation, where the total value is composed by the DSBs produced by electron and gamma particles. Moreover, the number of DSBMC stays between 0.016 ± 0.003 DSB∙cell–1∙mGy–1 (k = 1) for 99mTc and 0.012 ± 0.001 DSB∙cell–1∙mGy–1 (k = 1) for 177Lu. Lastly, the comparison of our simulation model against experimental data is illustrated in Fig. 5 (DSBMC vs. RIFExp). Two experimental data sets are used for comparison: 1) Eberlein et al. [14]: 0.0147 RIF∙cell−1∙mGy−1 (irradiation of blood with 177Lu and 131I) and 2) Schumann [17]: 0.0117 RIF∙cell−1∙mGy−1 (irradiation of blood with 177Lu, 90Y, 68Ga und 99mTc). Schumann’s study used a larger number of subjects and radionuclides than Eberlein’s study. Moreover, Schumann’s study used absorbed dose coefficients calculated for a blood vessel geometry [24], while Eberlein et al. [14] used absorbed dose coefficients calculated for the vial geometry used in the irradiation experiments.

Figure 4.

Figure 4

Total number of DSBs for beta- and gamma-emitter and their contributions per particle (electrons or gammas). Error bars consider a coverage factor (k) of 2.

Figure 5.

Figure 5

Comparison between the Monte Carlo-based total number of DSBMC for beta- and gamma-emitters and number of radio-induced foci (RIFExp) per cell measured experimentally [14], [15]. Error bars consider a coverage factor (k) of 2.

Range of absorbed doses in blood reached in the simulation

The activities associated with the number of simulated primary particles (equation (4)) are 0.56 MBq for 90Y, 2.4 MBq for 99mTc, 6.1 MBq for 123I, 2.3 MBq for 131I, 1.1 MBq for 177Lu, 0.3 MBq for 223Ra, and 0.3 MBq for 225Ac.

Using equation (5), the DAbsorbed,Blood for each radionuclide and its respective number of simulated primary particles (nt) was calculated. The values for radionuclides with beta and gamma emission are in the range of low absorbed doses (<100 mGy): 28.4 mGy for 90Y, 3.0 mGy for 99mTc, 6.1 mGy for 123I, 15.1 mGy for 131I, and 11.1 mGy for 177Lu.

For 223Ra and 225Ac the absorbed doses were 538 mGy and 544 mGy. Experimentally in alpha emitting radionuclides, the number of alpha tracks is used to quantify the DNA damage. Therefore, a high absorbed dose increased the number of possible alpha tracks improving the statistics of the simulation (observed on the error bars of Fig. 7).

Figure 7.

Figure 7

Comparison between the Monte Carlo-based total number of α-trackMC for alpha-emitters and the number of α-trackExp measured experimentally [15]. Error bars consider a coverage factor k = 2.

Cluster analysis for radionuclide beta and gamma emitters

Fig. 6A shows the number of clusters per cell and absorbed dose classified by the number of strand breaks, where only clusters with 1 strand break are certain to be single strand breaks (SSBs), while clusters with 2 strand breaks can be clusters with 2 SSBs in opposite strands (simple DSB) or clusters with 2 SSBs in the same strand. In clusters with 3 and 4 strand breaks, many DNA damage arrangements are possible (e.g., 3 strand breaks → 1) a complex DSB: 2 SSBs in one strand and 1 SSB in the opposite strand, 2) 3 SSBs in one strand. 4 strand breaks → 1) a complex DSB: 2 SSBs in one strand and 2 SSBs in the opposite strand, 2) 4 SSBs in one strand). Fig. 6B shows only the number of clusters with simple DSBs and complex DSBs per cell and absorbed dose.

Figure 6.

Figure 6

Cluster analysis (complexity of the DNA damage) for beta- and gamma-emitters: A) Classification of the cluster based on the number of strand breaks (SBs). B) Simple and complex DSBs. Error bars consider a coverage factor (k) of 2.

Comparison between α-trackMC and α-trackExp

Fig. 7 shows the number of α-tracks per 100 cells and absorbed dose (α-trackMC) obtained from the Monte Carlo simulation in Geant4-DNA and experimentally [15]. Two values were obtained from the simulation: 1) Monte Carlo simulation total number of α-trackMC: 0.1654 ± 0.0008 α-track·100 cell−1·mGy−1 for 223Ra and 0.1634 ± 0.0008 α-track·100 cell−1·mGy−1 for 225Ac. 2) Monte Carlo simulation with thresholds(α-trackMC,Threshold: α-trackMC larger than 0.75 µm in length and with more than 7 DSBs): 0.1654 ± 0.0008 α-track·100 cell−1·mGy−1 for 223Ra and 0.1634 ± 0.0008 α-track·100 cell−1·mGy−1. The relative error between the Monte Carlo simulation (total number of α-tracks) and the experimental data for 223Ra [15] is 17.3% for 223Ra, while the relative error between the Monte Carlo simulations with thresholds and the experimental data for 223Ra [15] is 2.7%.

Cluster analysis for radionuclide alpha emitters

Fig. 8A shows the number of clusters per cell and absorbed dose classified by the number of strand breaks as a parameter. Fig. 8B shows only the number of clusters per cell and absorbed dose with simple DSBs and complex DSBs. Furthermore, the linear density of DSBs per µm α-track length (DSBMC,α-track(DSB∙µm−1)) were 11.13 ± 0.04 DSB/µm and 10.86 ± 0.06 DSB/µm for 223Ra and 225Ac, respectively, aligning with experimental data for 223Ra [25].

Figure 8.

Figure 8

Cluster analysis (complexity of the DNA damage) for alpha-emitters: A) Classification of the cluster based on the number of strand breaks (SBs). B) Simple and complex DSBs.

Discussion

Data comparing results of Monte-Carlo simulations of DNA damage to experimental data are sparse and restricted to data obtained from experiments using X-ray irradiation [26] or ion microbeam irradiation of primary human endothelial cell cultures with alpha particles or protons [27].

In this study, we validated a DNA damage model for nuclei of human lymphocytes internally irradiated with radionuclides used in nuclear medicine at low absorbed doses (<100 mGy), occurring in blood during molecular radiotherapies [28], [29], by using the clustering example included in the Geant4-DNA simulation tool kit [4], [13]. This example is based on a clustering algorithm for grouping DNA strand breaks produced in a liquid water geometry. The validation was performed by comparing the results of the Monte Carlo simulation against actual experimental data [14], [15], [17].

In the first section of this study, we compare the absorbed dose coefficients for the lymphocyte nucleus (dLymph) (microscopic level) and whole blood (dBlood) (macroscopic level). Considering that the cell is defined as a cold source (without a self-irradiation component), the negative values observed in Fig. 3C are expected. The simulations of 99mTc and 123I sources presented the largest relative error. These differences might be related to the high gamma emission probability of these radionuclides and the low interaction probability of gamma particles with the water medium. This results in 99mTc and 123I sources having the largest number of DSBs caused by gamma particles (see Fig. 4C) in comparison with 90Y, 131I, and 177Lu sources. The only parameter in the Geant4-DNA simulation that permits adjusting the deposited energy (therefore, the absorbed dose coefficients) is the low energy limit of the production of secondary electrons (production thresholds in the G4ProductionCutsTable). Based on our user experience, this threshold directly impacts the energy deposition and DSBs production, for which both parameters follow a direct proportionality. In this study, the production threshold was optimized to reach the lowest difference between the absorbed dose coefficients for the lymphocyte nucleus (dLymph) (microscopic level) and whole blood (dBlood) (macroscopic level), always favoring a negative difference.

In Fig. 3 we show that the number of DSBMC for all the beta and gamma emitter radionuclides are in a similar range independently of the differences in the emission probabilities (e.g., 99mTc (140 keV, gamma) vs. 90Y (2.28 MeV, higher energy beta emissions)) [30]. Experimentally, Schumann [17] reported non-significant differences in the induction of RIF when considering the type of radionuclide or the individual subject for irradiation of blood with different radionuclides 177Lu, 90Y, 68Ga und 99mTc in a group of four subjects and 16 blood samples.

The comparison of DSBMC and RIFExp (Fig. 5) reveals that the DSBs calculated by simulation fall within the range of the values of two experimental data sets [14], [17] (assuming a 1:1 correspondence between RIF and DSB at a low absorbed dose range). The clustering example (based on a DBSCAN algorithm) estimates the DSBs using probabilistic criteria (SPointsProb and damage probability). The SPointsProb defines a uniform probability that a particle interaction is located inside a sensitive volume where this interaction can directly or indirectly reach the DNA [4]. The SPointsProb is specific for the simulation geometry and should be selected to meet the experimental results. However, in this study, the SPointsProb was obtained under geometrical criteria (considering the DNA volume as a cylinder of 1.1 × 10−9 m radius [21] and a length of 2.2 m [21] and dividing the volume of this cylinder by the volume of the lymphocyte nucleus). Piovesan et al. [31] estimated the mass of the human male and female genomes at 6.41 g and 6.51 g, respectively. These mass values led to a volume of 3.8 mL (using a DNA mass density of 1.7 g/mL [32] for the human male and female genomes. A 3.8 mL DNA volume resulted in a SPointsProb of 3%. This molecular-based value differs by 4% from the value used in this study. Francis et al. [4] defined the sensitive volume in a DBSCAN algorithm as the volume occupied by the DNA double helix plus a virtual aura surrounding the DNA. Bertolet et al. [33] demonstrated that Monte Carlo simulations of DNA damage encompass different volume models and specific parameters, which must be selected to meet experimental results. Therefore, the difference between a cylindrical- and molecular-based SPointsProb is necessary to consistently match the simulation with the experimental data for lymphocytes ex vivo irradiated with gamma-, beta-, and alpha-emitting radionuclides.

The complexity of the DNA damage was approached with the experiments underlying Fig. 6 by quantifying the number of simple and complex DSBs [34]. The number of DSBs calculated by Monte Carlo simulation is for the different gamma and beta emitters within the same range. In Fig. 5, as in Fig. 6B, it is shown that the number of DSBs for the 99mTc and 123I radionuclides presented the largest error bars, which agrees with the error bars of the absorbed dose coefficients at the microscopic level in Fig. 3A.

The Monte Carlo simulation (without experimental thresholds) provides a larger number per 100 cells of α-tracks than the experimental data (Fig. 7). These differences might be related to the resolution limit of standard fluorescence microscopy (0.25–3 µm) [35]. Experimentally, to define an alpha track one needs at least three adjacent foci in a row [25], which corresponds to a shortest track of 0.75–0.9 µm. Moreover, experimentally only the roughly parallel traversing α-tracks can be easily identified. This study proposes experimental-based thresholds (α-tracks larger than 0.75 µm and with more than 7 DSBs [35], which show good agreement between the Monte Carlo-based α-tracks values and the experimental data [18].

The complexity of the DNA damage produced by alpha particles (Fig. 8) is higher than that produced by beta and gamma emitters (Fig. 6) [34], [36]. This complexity makes it impracticable to establish a relationship between DSBs and RIF. Therefore, the linear density of DSBs per micrometer α-track length (DSBMC,α-track) is used to assess the DNA damage produced by alpha particles. In this study, we calculate DSBMC,α-track values of 11.13 ± 0.04 DSB/µm and 10.86 ± 0.06 DSB/µm for 223Ra and 225Ac, respectively. Du et al. [23], in a cell irradiation experiment with 55 MeV carbon ions, quantify a DSBMC,α-track of 15 DSB/μm using the PARTRAC code [37]. In our study, the kinetic energy of alpha particles registered in the phase space stays between 0.01 MeV and 8.36 MeV for 223Ra and 0.01 MeV and 8.36 MeV for 225Ac. Therefore, considering the energy and particle mass differences our values are in a similar range than Du et al. [23]. In addition, Scherthan et al. [25] investigated the DNA damage caused by α-tracks of 223Ra in-solution irradiated leukocytes using super-resolution light microscopy (SMLM) with cluster analysis of single molecule signal-point density regions to observe the nanostructures of DNA damage α-tracks. They reported that in average 12 DSBs may be contained in the damaged area of an average γ-H2AX alpha particle track of 1.27 µm2 (diameter of a circular area = 1.27 µm) in a lymphocyte nucleus of 35 µm2 (in our study, the size of the nucleus used in the Monte Carlo simulation is 30.2 µm2). This results in a linear density of DSBs per micrometer of α-track length of 9.45 DSB/µm (12 DSB/1.27 µm). These data are in very good agreement with our simulation data.

Comparison with previous X-ray irradiation studies

A first reference on the number of DSBs per cell per Gy in mammalian cells caused by low-LET radiation exposure is in Ward [38], who reported a value of 40 DSB·Cell−1·Gy−1. Most likely, this value is based on theoretical considerations and data obtained from electrophoretic DNA double-strand break assays. These assays are sensitive at absorbed doses of more than 1 Gy [39], a dose range not considered in this work. For lower absorbed doses, RIF, have been established as surrogate markers for DSBs [39].

Rothkamm et al. [40] reported a value of 36 RIF·cell−1·Gy−1 in primary human lung fibroblasts cells (MRC-5) in G1 phase under X-ray irradiation (90 kVp X-ray, dose rate of 2 Gy/min). Horn et al. [41] reported a value of 15.7 RIF·cell−1·Gy−1 for the irradiation of blood collected in EDTA vacutainer tubes using a 250 kVp X-ray source (dose rate of 1.7 Gy/min). As Barnard et al. [39] pointed out, an explanation of this difference could be that the absolute yield per unit absorbed dose changes linearly with the DNA content of the cells. Furthermore, the number of RIF/cell possibly depends substantially on the cell cycle [39], nuclear diameter and cell type.

For lymphocytes the value reported by Horn et al. is in agreement with our simulated data (assuming 1 RIF ≈ 1 DSB, between 12 DSB∙cell−1∙Gy−1 (99mTc), and 16 DSB∙cell−1∙Gy−1 (177Lu)) and the experimental data used as a reference in this study (15 RIF∙cell−1∙Gy−1 [14] and 11 RIF∙cell−1∙Gy−1 [17].

Study limitations

This Monte Carlo simulation model was validated against experimental data of lymphocytes irradiated with beta- and gamma-emitting radionuclides [14], [17] and 223Ra (alpha emitter) [15], [25] at low absorbed doses (<100 mGy). Therefore, this model is applicable to quantify the DNA damage in lymphocytes at low absorbed doses.

In this study, lymphocytes are modelled by spheres with a mean radius of 3.75 µm and nuclei with a radius of 3.1 µm. This approach has two advantages: 1) The irradiation profile of the lymphocytes’ considers the irradiation at several points inside the vial (centre and periphery). 2) A single simulation is required in Geant4-DNA using the sum of the 1000 phase spaces, which makes it possible to use a large number of particles, improve the statistics and optimize the simulation time at the cellular level. However, this approach does not represent the lymphocytes’ variation in size (e.g. Loiko et al. [20] found in a group of 16 individuals that the lymphocyte radius varied from 2.4 to 6.0 µm). Therefore, further studies will consider the uncertainty of lymphocytes’ size distribution.

Furthermore, further studies considering a three-dimensional DNA structure and indirect damage are necessary to assess individually all the components of the DNA and evaluate the impact of the spatial distribution of the DNA (e.g., helical periodicity of DNA on the nucleosome) damage in lymphocytes irradiated with radionuclides.

Conclusion

This study validated a model to simulate the DNA damage for lymphocytes ex vivo irradiated with gamma, beta, and alpha-emitting radionuclides, assuming a 1:1 correspondence between RIF and DSB at a low absorbed dose range doses (<100 mGy). Moreover, it provides a methodology to reproduce the spatial distribution of lymphocytes in the volume of an irradiation vial and to determine the absorbed dose coefficient to lymphocytes in 1 mL of blood (dLymph) for 1 h of internal ex vivo irradiation of whole blood, as applied in experimental settings [14], [15], [17]. In addition, this study provides a detailed methodology to couple a macroscopic model (vial) with a microscopic model (lymphocytes nucleus).

Geant4-DNA provides complementary information in assessing the DNA damage produced by alpha particles, explicitly quantifying the linear density of DSBs per micrometer along the length of an α-track and the number of simple and complex DSBs.

The sensitive volume (SPointsProb = 7%) used in this study provides a reliable approximation to assess the DNA damage that consistently matches the simulation data with the experimental data.

Author contributions

All authors participated in the study design. Maikol Salas-Ramirez performed the methodology and calculations. All authors analyzed and interpreted the data and wrote the manuscript.

Funding

This work was supported by a contract research project for the Bundeswehr Medical Service (Research grant number: E/U2AD/KA367/KF554) and in part by the German Research Foundation (Deutsche Forschungsgemeinschaft, Grant Number 509851852).

Maikol Salas-Ramirez was supported by funds of the Bavarian State Ministry of Science and Arts and the Graduate School of Life Sciences (GSLS) of the University of Würzburg.

The funders had no role in the study design, data collection and analysis, or manuscript preparation.

Data Availability Statement

C++ and Python codes can be requested from the corresponding author.

Declaration of Competing Interest

The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: M. Lassmann has received institutional grants by IPSEN Pharma, Nordic Nanovector, and Novartis. No other potential conflicts of interest relevant to this article exist.

Footnotes

Appendix A

Supplementary data to this article can be found online at https://doi.org/10.1016/j.zemedi.2023.07.007.

Appendix A. Supplementary data

The following are the Supplementary data to this article:

Supplementary Data 1
mmc1.pdf (943.8KB, pdf)

References

  • 1.Chatzipapas K.P., Papadimitroulas P., Emfietzoglou D., et al. Ionizing radiation and complex DNA damage: quantifying the radiobiological damage using Monte Carlo simulations. Cancers. 2020;12 doi: 10.3390/cancers12040799. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Kyriakou I., Sakata D., Tran H.N., et al. Review of the Geant4-DNA simulation toolkit for radiobiological applications at the cellular and DNA level. Cancers. 2022;14 doi: 10.3390/cancers14010035. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.McNamara A.L., Ramos-Méndez J., Perl J., et al. Geometrical structures for radiation biology research as implemented in the TOPAS-nBio toolkit. Phys Med Biol. 2018;63:175018. doi: 10.1088/1361-6560/aad8eb. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Francis Z., Villagrasa C., Clairand I. Simulation of DNA damage clustering after proton irradiation using an adapted DBSCAN algorithm. Comput Meth Prog Biomed. 2011;101:265–270. doi: 10.1016/j.cmpb.2010.12.012. [DOI] [PubMed] [Google Scholar]
  • 5.Nikjoo S., Uehara W.E., Wilson M., Hoshi D.T., Goodhead H. Track structure in radiation biology: theory and applications. Int J Radiat Biol. 1998;73:355–364. doi: 10.1080/095530098142176. [DOI] [PubMed] [Google Scholar]
  • 6.Friedland W., Paretzke H.G., Ballarini F., Ottolenghi A., Kreth G., Cremer C. First steps towards systems radiation biology studies concerned with DNA and chromosome structure within living cells. Radiat Environ Biophys. 2008;47:49–61. doi: 10.1007/s00411-007-0152-x. [DOI] [PubMed] [Google Scholar]
  • 7.Penninckx S., Pariset E., Cekanaviciute E., Costes S.V. Quantification of radiation-induced DNA double strand break repair foci to evaluate and predict biological responses to ionizing radiation. NAR Cancer. 2021;3 doi: 10.1093/narcan/zcab046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Sébastien P., Egle C., Charlotte D., et al. Dose, LET and strain dependence of radiation-induced 53BP1 Foci in 15 mouse strains ex vivo introducing novel DNA damage metrics. Radiat Res. 2019;192:1–12. doi: 10.1667/RR15338.1. [DOI] [PubMed] [Google Scholar]
  • 9.Jan S., Benoit D., Becheva E., et al. GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy. Phys Med Biol. 2011;56:881–901. doi: 10.1088/0031-9155/56/4/001. [DOI] [PubMed] [Google Scholar]
  • 10.Sarrut D., Bardiès M., Boussion N., et al. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications. Med Phys. 2014;41 doi: 10.1118/1.4871617. [DOI] [PubMed] [Google Scholar]
  • 11.Allison J., Amako K., Apostolakis J., et al. Recent developments in Geant4. Nucl Instrum Meth Phys Res Sect A: Accelerat Spectromet Detectors Assoc Equip. 2016;835:186–225. [Google Scholar]
  • 12.Incerti S., Baldacchino G., Bernal M., et al. The GEANT4-DNA project. Int J Model Simul Scientific Comput. 2010;01:157–178. [Google Scholar]
  • 13.Incerti S., Kyriakou I., Bernal M.A., et al. Geant4-DNA example applications for track structure simulations in liquid water: a report from the Geant4-DNA project. Med Phys. 2018;45:e722–e739. doi: 10.1002/mp.13048. [DOI] [PubMed] [Google Scholar]
  • 14.Eberlein U., Peper M., Fernández M., Lassmann M., Scherthan H. Calibration of the γ-H2AX DNA double strand break focus assay for internal radiation exposure of blood lymphocytes. PLoS One. 2015;10 doi: 10.1371/journal.pone.0123174. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Göring L., Schumann S., Müller J., et al. Repair of α-particle-induced DNA damage in peripheral blood mononuclear cells after internal ex vivo irradiation with 223Ra. Eur J Nucl Med Mol Imag. 2022;49:3981–3988. doi: 10.1007/s00259-022-05860-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Schumann S., Eberlein U., Lapa C., et al. α-Particle-induced DNA damage tracks in peripheral blood mononuclear cells of [223Ra]RaCl2-treated prostate cancer patients. Eur J Nucl Med Mol Imag. 2021;48:2761–2770. doi: 10.1007/s00259-020-05170-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Schumann S. Germany, University of Würzburg; Würzburg: 2022. Zeit- und Dosisabhängigkeit von DNA-Schäden induziert durch interne Bestrahlung mit unterschiedlichen Radionukliden Time and dose dependence of DNA damage induced by internal irradiation with various radionuclides. [Doctoral Thesis] [Google Scholar]
  • 18.Schumann S., Eberlein U., Muhtadi R., Lassmann M., Scherthan H. DNA damage in leukocytes after internal ex-vivo irradiation of blood with the alpha-emitter Ra-223. Sci Rep. 2018;8:2286. doi: 10.1038/s41598-018-20364-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Salas-Ramirez M., Lassmann M., Eberlein U. GATE/Geant4-based dosimetry for ex vivo in solution irradiation of blood with radionuclides. Zeitschrift für Medizinische Physik. 2022 doi: 10.1016/j.zemedi.2022.03.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Loiko V.A., Ruban G.I., Gritsai O.A., et al. Morphometric model of lymphocyte as applied to scanning flow cytometry. J Quant Spectrosc Radiat Transfer. 2006;102:73–84. [Google Scholar]
  • 21.Klug A., Lutter L.C. The helical periodicity of DNA on the nucleosome. Nucleic Acids Res. 1981;9:4267–4283. doi: 10.1093/nar/9.17.4267. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.McPherson J.D., Marra M., Hillier L., et al. A physical map of the human genome. Nature. 2001;409:934–941. doi: 10.1038/35057157. [DOI] [PubMed] [Google Scholar]
  • 23.Guanghua D., Guido A.D., Werner F., et al. Spatial dynamics of DNA damage response protein foci along the ion trajectory of high-LET particles. Radiat Res. 2011;176:706–715. doi: 10.1667/rr2592.1. [DOI] [PubMed] [Google Scholar]
  • 24.Hänscheid H., Fernandez M., Eberlein U., Lassmann M. Self-irradiation of the blood from selected nuclides in nuclear medicine. Phys Med Biol. 2014;59:1515–1531. doi: 10.1088/0031-9155/59/6/1515. [DOI] [PubMed] [Google Scholar]
  • 25.Scherthan H., Lee J.-H., Maus E., et al. Nanostructure of clustered DNA damage in leukocytes after in-solution irradiation with the alpha emitter Ra-223. Cancers. 2019;11 doi: 10.3390/cancers11121877. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Freneau A., Dos Santos M., Voisin P., et al. Relation between DNA double-strand breaks and energy spectra of secondary electrons produced by different X-ray energies. Int J Radiat Biol. 2018;94:1075–1084. doi: 10.1080/09553002.2018.1518612. [DOI] [PubMed] [Google Scholar]
  • 27.Gonon G., Villagrasa C., Voisin P., et al. From energy deposition of ionizing radiation to cell damage signaling: benchmarking simulations by measured yields of initial DNA damage after ion microbeam irradiation. Radiat Res. 2019;191:566–584. doi: 10.1667/RR15312.1. [DOI] [PubMed] [Google Scholar]
  • 28.Schumann S., Scherthan H., Lapa C., et al. DNA damage in blood leucocytes of prostate cancer patients during therapy with 177Lu-PSMA. Eur J Nucl Med Mol Imag. 2019;46:1723–1732. doi: 10.1007/s00259-019-04317-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Eberlein U., Nowak C., Bluemel C., et al. DNA damage in blood lymphocytes in patients after 177Lu peptide receptor radionuclide therapy. Eur J Nucl Med Mol Imag. 2015;42:1739–1749. doi: 10.1007/s00259-015-3083-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Becquerel LNH. Table of RADIONUCLIDES; 2023. http://www.lnhb.fr/nuclear-data/nuclear-data-table/.
  • 31.Piovesan A., Pelleri M.C., Antonaros F., Strippoli P., Caracausi M., Vitale L. On the length, weight and GC content of the human genome. BMC Res Notes. 2019;12:106. doi: 10.1186/s13104-019-4137-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Prosser J., Reisner A.H., Bradley M.L., Ho K., Vincent P.C. Buoyant density and hybridization analysis of human DNA sequences, including three satellite DNAs. Biochim Biophys Acta. 1981;656:93–102. doi: 10.1016/0005-2787(81)90031-9. [DOI] [PubMed] [Google Scholar]
  • 33.Alejandro B., José R.-M., Aimee M., et al. Impact of DNA geometry and scoring on Monte Carlo track-structure simulations of initial radiation-induced damage. Radiat Res. 2022;198:207–220. doi: 10.1667/RADE-21-00179.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Sage E., Shikazono N. Radiation-induced clustered DNA lesions: repair and mutagenesis. Free Radical Biol Med. 2017;107:125–135. doi: 10.1016/j.freeradbiomed.2016.12.008. [DOI] [PubMed] [Google Scholar]
  • 35.Scherthan H., Hieber L., Braselmann H., Meineke V., Zitzelsberger H. Accumulation of DSBs in γ-H2AX domains fuel chromosomal aberrations. Biochem Biophys Res Commun. 2008;371:694–697. doi: 10.1016/j.bbrc.2008.04.127. [DOI] [PubMed] [Google Scholar]
  • 36.Nikitaki Z., Nikolov V., Mavragani I.V., et al. Measurement of complex DNA damage induction and repair in human cellular systems after exposure to ionizing radiations of varying linear energy transfer (LET) Free Radical Res. 2016;50:S64–S78. doi: 10.1080/10715762.2016.1232484. [DOI] [PubMed] [Google Scholar]
  • 37.Werner F., Peter J., Pavel K. Stochastic simulation of DNA double-strand break repair by non-homologous end joining based on track structure calculations. Radiat Res. 2010;173:677–688. doi: 10.1667/RR1965.1. [DOI] [PubMed] [Google Scholar]
  • 38.Ward J.F. In: Progress in Nucleic Acid Research and Molecular Biology. Cohn W.E., Moldave K., editors. Academic Press; 1988. DNA damage produced by ionizing radiation in mammalian cells: identities, mechanisms of formation, and reparability; pp. 95–125. [DOI] [PubMed] [Google Scholar]
  • 39.Barnard S., Bouffler S., Rothkamm K. The shape of the radiation dose response for DNA double-strand break induction and repair. Genome Integr. 2013;4:1. doi: 10.1186/2041-9414-4-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Rothkamm K., Löbrich M. Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses. Proc Natl Acad Sci. 2003;100:5057–5062. doi: 10.1073/pnas.0830918100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Horn S., Barnard S., Rothkamm K. Gamma-H2AX-based dose estimation for whole and partial body radiation exposure. PLOS One. 2011;6 doi: 10.1371/journal.pone.0025113. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Data 1
mmc1.pdf (943.8KB, pdf)

Data Availability Statement

C++ and Python codes can be requested from the corresponding author.


Articles from Zeitschrift für Medizinische Physik are provided here courtesy of Elsevier

RESOURCES