Skip to main content
IOP Publishing logoLink to IOP Publishing
. 2025 Dec 3;27(12):123001. doi: 10.1088/2040-8986/ae1bb8

Roadmap on advances in visual and physiological optics

Jesús E Gómez-Correa 1,28,*,, Brian Vohnsen 2,28,*,, Barbara K Pierścionek 3,28,*,, Sabino Chávez-Cerda 1,28,*,, Sabine Kling 4, Jos J Rozema 5,6, Raymond A Applegate 7, Giuliano Scarcelli 8, J Bradley Randleman 9, Alexander V Goncharov 10, Amy Fitzpatrick 2, Jessica I W Morgan 11,12, Austin Roorda 13, David A Atchison 14, Juan P Trevino 15,16, Alejandra Consejo 17, Charlie Börjeson 18, Linda Lundström 18, Seung Pil Bang 19, Geunyoung Yoon 7, Karol Karnowski 20,21, Bartlomiej J Kaluzny 22, Ireneusz Grulkowski 23, Sergio Barbero 24, Pablo Artal 25, Juan Tabernero 25, Pete Kollbaum 26, Stéphanie C Thébault 27
PMCID: PMC12673259  PMID: 41346852

Abstract

The field of visual and physiological optics is undergoing continuous significant advancements, driven by a deeper understanding of the human visual system and the development of cutting-edge optical technologies. This Roadmap, authored by leading experts, delves into critical areas such as corneal biomechanical properties, keratoconus, and advancements in corneal imaging and elastography. It explores the intricate structure–function relationship within the eye lens, offering new perspectives through lens models and ray tracing techniques. The document also covers advancements in retinal imaging, highlighting the current state and future directions, and the role of adaptive optics in evaluating retinal structure and function in both healthy and diseased eyes. Furthermore, it addresses the modeling of ocular surfaces using different mathematical functions and examines the factors affecting peripheral image quality in the human eye, emphasizing the importance of these aspects in visual performance. Additional topics include schematic and functional models of the human eye, the impact of optical and chromatic aberrations, and the design of contact, and intraocular lenses. Finally, the Roadmap addresses the intersection of neurosciences with vision health, presenting a comprehensive overview of current research and future trends aimed at improving visual health and optical performance. Ultimately, this Roadmap aims to serve as a valuable resource for ophthalmologists, optometrists, vision scientists, and engineers dedicated to advancing the field of visual and physiological optics.

Keywords: cornea, the human eye lens, photoreceptors (retinal imaging), schematic models, peripheral vision, contact and intraocular lenses, neuroscience of vision

1. Introduction

Jesús E Gómez-Correa1, Brian Vohnsen2, Barbara K Pierścionek3 and Sabino Chávez-Cerda1

1Instituto Nacional de Astrofísica, Óptica y Electrónica, Coordinación de Óptica, Pue. 72840, Mexico

2Optics Group, School of Physics, University College Dublin, Beech Hill, Ireland

3Faculty of Health, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Bishops Hall Lane, Chelmsford, United Kingdom

E-mail: jgomez@inaoep.mx, brian.vohnsen@ucd.ie, barbara.pierscionek@aru.ac.uk and sabino@inaoep.mx

From ancient Greece to Kepler’s revolutionary ideas, vision was interpreted as an interaction between the eye and external objects with differing views on the source of optical elements. For example, by the mid-first millennium B.C., the first documented speculations about vision had emerged. In popular Greek belief, it was thought that the eye emitted a fire whose rays explored the surface of the observed object, known as ‘visual fire’. However, not all philosophers accepted this theory, most notably—the atomists—who opposed it and reduced all sensations to the impact of atoms emanating from the object onto the organ of vision. Other philosophers believed that vision depended on a medium that propagated the form, which was considered inert and sensitive. Others believed in the idea of rays that emanated from the eye at defined angles to observe objects, a concept that formed the basis of geometric optics. In the 11th century, Alhazen revolutionized the theory of vision by proposing that vision depended on light entering the eye after being diffusely reflected by the surface of objects. Centuries later, Kepler completed Alhazen’s idea by arguing that the image of the object was formed on the retina. He understood that this image was generated by the intersection of all rays coming from a luminous point, allowing the distance to the object to be measured. With this idea, Kepler turned the eye into an optical instrument and demonstrated how instruments could correct or enhance vision [1, 2].

Today, the field of optics has evolved far beyond its early theoretical foundations. Modern advancements in optical technologies, such as lasers, imaging systems, optical sensors, adaptive optics in combination with computational modeling, have all been vital in helping us understand how the biology of the eye is linked to its optical function and the visual system. These innovations have led to the development of sophisticated instruments and techniques for diagnosing and treating eye conditions and exploring the intricate workings of the human eye at a level of detail unimaginable in earlier times.

Building on these advancements, the ‘Roadmap on advances in visual and physiological optics’, authored by leading experts, delves into critical areas that are shaping the future of vision science. This comprehensive document explores topics from the cornea and all the way through to the brain and visual cortex including corneal biomechanics, keratoconus (KC), and cutting-edge techniques in corneal imaging and elastography. It also examines the complex structure–function relationship within the eye lens, utilizing advanced lens models and ray tracing techniques to offer new insights. The Roadmap highlights the latest advancements in retinal imaging, adaptive optics, and the modeling of ocular surfaces, addressing their implications for visual performance and the treatment of eye diseases. Additionally, it covers the impact of optical and chromatic aberrations, the design of progressive lenses, contact lenses, and intraocular lenses (IOLs), as well as the integration of the retina and neurosciences into vision health. By providing a forward-looking overview of current research and emerging trends, we hope that this Roadmap will serve as an invaluable resource for professionals dedicated to advancing the field of visual and physiological optics, guiding future innovations aimed at enhancing both optical performance and overall visual health of humanity.

2. Corneal biomechanical properties

Sabine Kling

ARTORG Center for Biomedical Engineering Research, University of Bern, Freiburgstrasse 3, 3010 Bern, Switzerland

E-mail: sabine.kling@unibe.ch

Status

Understanding the mechanical behavior of the cornea is critical to discern health from disease, but also to accurately predict surgical outcomes. The cornea exhibits complex mechanical properties, which allow for its transparency, dome-shaped geometry and its extraordinary stable refractive performance, even under varying intraocular pressure (IOP). Recent advances in this field include higher resolved [3, 4] and non-contact [5, 6] mechanical characterization techniques, computational modeling [7, 8], and new clinical applications [9, 10], enhancing our knowledge of corneal biomechanics and its role in ocular pathologies (figure 1).

Figure 1.

Figure 1.

Key areas of corneal biomechanics and their interactions. Quantifying corneal deformation characteristics and structural alterations is helpful for early diagnosis of corneal ectatic diseases. Modeling can predict patient-specific refractive outcomes and assist in the retrieval of an individual’s material properties from macroscopic deformation measurements. Finally, clinical application will benefit from a pre-op comparison of different surgical techniques and a more accurate refractive outcome. OCE: optical coherence elastography, psOCT: polarization sensitive OCT, OCT: optical coherence tomography.

KC is a progressive ectatic disorder that locally degrades the tissue’s mechanical integrity resulting in corneal thinning, localized steepening and severe visual degradation. New diagnostic tools aim at detecting subclinical KC, facilitating early diagnosis and intervention. Myopia, another common refractive condition, has recently been investigated in the context of corneal biomechanics. Myopic eyes, particularly those with severe elongation, were reported to exhibit altered biomechanical properties, when measured in vivo [1113]. However, this observation might be a measurement artifact, resulting from the use of evaluation metrics outside of their calibrated range. Since myopia involves both geometrical changes and potential mechanical alterations, characterizing the effect of purely geometrical effects on corneal deformation is critical to assess mechanical properties. More objective evaluations of the role of corneal biomechanics in myopia will be necessary, before this relationship can be used to assess the progression of myopia and the associated risk of complications.

The most often conduced mechanical in vivo measurements of the corneal assess the deformation dynamics induced by an air-puff via the ocular response analyzer [6] (ORA) and the Corvis ST [5] (CST). While the originally mostly geometrical parameters retrieved from air-puff measurements were strongly dependent on confounding factors such as IOP and ocular geometry (corneal thickness), more recently advanced parameters have been derived based on large clinical data sets to define more robust parameters (Corvis biomechanical index [14]—CBI, tomographic biomechanical index [15]—TBI) to distinguish normal from KC and ectatic corneas. Further air-puff parameters are the biomechanically-corrected IOP (bIOP) providing a less biased measure of the actual IOP and the stress–strain index [5] objectively assessing the corneal stiffness independent of corneal thickness and IOP. Experimental techniques such as reverberant [16] optical coherence elastography (OCE), so far applied only ex vivo, or in vivo micro-forced shear-wave [4], or quasi-static [17] OCE pose promising alternatives to quantify corneal biomechanics with higher spatial resolution providing a more comprehensive assessment of tissue heterogeneity. Another promising approach is motion-tracking Brillouin microscopy, which successfully quantified the local decrease in corneal stiffness in KC patients [3].

Advances in finite element analysis reduce the amount of approximations by accounting for the pre-stress by the IOP, collagen fibril orientation, non-linear material properties and patient-specific geometries with the aim of predicting the outcome of refractive interventions and optimizing treatment protocols on an individual’s own model eye. While IOP and patient-specific geometries are routinely measured in clinical practice, the in vivo assessment of mechanical properties and approximation of collagen fibril orientation is more complex and not routinely performed. FEA is also a promising tool for inversely retrieving corneal material properties from in vivo corneal deformation measurements [18].

Current and future challenges

A primary challenge in current clinical biomechanical assessments is their indirect nature and the lack of standardized measurement techniques. Differences in the principles and outputs of ORA and CST prevent a comparison of their mechanical measures. Their strong dependency on IOP and corneal thickness demand for complex processing algorithms to derive corneal stiffness, which themselves rely on certain approximations on ocular geometry, material properties and boundary conditions, preventing their application as a universal measurement tool in all patients.

The complex layered structure of the cornea and its anisotropic, visco-hyperelastic material properties make it difficult to model and analyze accurately. Variations in collagen fiber orientation and corneal hydration levels can only be indirectly estimated in vivo and the assessment of regional differences in corneal stiffness via elastography rests in its infancy—making important modeling parameters difficult to obtain. In consequence, models and diagnostic tools often simplify these aspects, limiting their accuracy and applicability in clinical practice.

Significant inter-individual variability in corneal biomechanics exists due to genetic, environmental and lifestyle factors. This variability makes generalized diagnostic and treatment protocols unreliable and demands for personalized assessment tools and treatment protocols. The integration of both, biomechanical and other clinically available diagnostic information, such as topography, tomography and optical coherence tomography (OCT) in more sophisticated models promise more refined diagnostics and more accurate predictions of the surgical outcome. This is particularly relevant for corneal surgeries, such as LASIK, SMILE, and corneal cross-linking (CXL), which alter the corneal structure and mechanics.

A more detailed understanding of the factors influencing corneal biomechanics could also allow a better patient-specific risk estimation of developing iatrogenic ectasia and supplement pre-surgical biomechanical screening before laser refractive surgeries. Moreover, being able to model the dynamics of degenerative corneal diseases could help forecasting the individual speed of progression and assist in determining the adequate treatment schedule and protocol.

A still unmet and unaddressed challenge is the prediction of post-surgical wound healing effects, which are inherently accompanied by biomechanical changes. This includes epithelial and stromal remodeling after intracorneal ring segment implantation and laser refractive surgery, but also ongoing corneal flattening after CXL treatment. Currently, these processes limit the predictability of long-term post-surgical refractive results.

Advances in science and technology to meet challenges

Future advancements in imaging and measurement technologies are expected to enhance the resolution of biomechanical assessments and their sensitivity to detect early disease stages. Techniques such as OCE could provide more detailed insights into corneal biomechanics at both the macroscopic and microscopic levels [4, 17]. With advances in imaging speed, refractive and biomechanical treatment monitoring during CXL treatment might become possible and allow tailored biomechanical modification in an individual patient. Polarization sensitive OCT (psOCT) [19] is a promising tool to provide in vivo patient-specific information about tissue birefringence, which is inherently related to its microstructure, providing a relevant modeling input. Along the same line, advanced OCT signal interpretation algorithms such as nanosensitive OCT [20] demonstrated their potential to extract ultrastructural information out of standard OCT scans and could similarly provide insights into the collagen network.

The development of more sophisticated computational models that can simulate the complex mechanical interaction of the cornea and other ocular tissues (crystalline lens, sclera) and directly relate mechanical with optical changes is a major future challenge. Comprehensive opto-biomechanical eye models [21, 22] are being developed promising the evaluation of distinct surgical interventions in a digital twin before choosing the best treatment option. Enhancing these models by individual opto-mechanical measures and validating their predictions under distinct optical and mechanical demands will require significant advancements in computational power and algorithms.

The application of artificial intelligence (AI) might allow to reduce the computational load of numerical simulations and to identify novel biomarkers for corneal degradation in the future. Big data analytics could also provide deeper insights into the progression of diseases like KC and myopia, as well as the long-term stability of surgical interventions. With digital patient files readily available and decreasing storage costs, the collection of extensive datasets over time has become more feasible.

Concluding remarks

Corneal biomechanics is a dynamic and critical area of ophthalmic research. Advances in diagnostic tools—like the ORA and CST, along with innovative techniques such as OCE and Brillouin microscopy—have significantly enhanced our ability to assess corneal biomechanics in vivo. These developments are vital for the early detection and management of degenerative conditions like KC and myopia, where biomechanical properties play an important role in disease progression.

Current challenges include standardizing measurement techniques, integrating biomechanical data with other diagnostic modalities, and accounting for inter-individual variability. Future challenges lie in developing more advanced imaging technologies, improving computational models, and implementing personalized medicine approaches. Addressing these challenges requires ongoing interdisciplinary research, technological innovation, and clinical collaboration. As we continue to refine our understanding and tools, the potential for improving patient outcomes through better diagnostic and treatment strategies in corneal biomechanics is substantial.

Acknowledgements

This work received funding from the European Union’s HORIZON 2020 research and innovation programme under Grant Agreement No. 956720.

3. KC, corneal aberrations, and their correction

Jos J Rozema1,2 and Raymond A Applegate3

1Visual Optics Laboratory Antwerp, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium

2Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium

3College of Optometry, University of Houston, Houston TX, United States of America

E-mail: jos.rozema@uantwerpen.be and raappleg@central.uh.edu

Status

KC is progressive corneal ectasia that typically first manifests in the late teenage years with an estimated prevalence [23] of about 1:375 and a male to female ratio of 2.6:1 [24]. The condition is bilateral but does not necessarily affect both eyes simultaneously or to the same degree, often leading to very large differences in visual quality between eyes of the same individual, while the rate of progression and severity can vary widely [25]. Although the cause is unknown, there is a hereditary component, while eye rubbing and allergies are known to exacerbate it [24]. The irregular corneal shape found in KC, pellucid degeneration, corneal trauma, or after some corneal surgical interventions, lead to increased amounts of higher order wavefront aberrations. Often, such aberrations lead to a decrease in acuity. Whether high contrast acuity is lost or not, visual image quality is decreased. As the onset of the disease occurs just before early adulthood, when individuals head off to college or establish their careers and families, it is a particularly difficult time for them to learn about having an eye disease that will progressively affect their vision. Based on their visual experiences before the onset of the disease patients expect solutions that return their original, healthy sight. But while challenging, many solutions exist that help patients regain some of their lost visual image quality. Wavefront guided scleral lenses, in many cases, reduce aberrations to age and pupil size normal levels.

Current and future challenges

Much like typical eyes, individuals with early KC may be satisfied with the visual image quality provided by standard spherical or sphero-cylindrical spectacles, or soft contact lens corrections. As the disease progresses, however, the increasing amounts of higher order aberrations will cause such corrections to gradually fail to meet the patients’ visual needs. The next level of correction is the corneal gas permeable rigid contact lens that, if designed and fitted correctly, provides a smooth first surface while creating an index matching tear lens between the lens and cornea. This significantly reduces the defocus and astigmatism, as well as the higher order aberrations by approximately 60% [26]. More advanced cases see the clearing between cornea and lens become so narrow that both may start to rub each other, leading to corneal scarring or ulcers. To prevent scarring or ulcers, scleral lenses become the standard of care as they vault over the distorted corneal surface. But as the disease progresses the index matching of rigid lenses may no longer be adequate to the patient’s needs as these only partially compensate the higher order aberrations of the anterior corneal surface and ignore those of the posterior corneal surface [27]. These limitations are beginning to be addressed by wavefront guided (WFG) rigid scleral lenses, designed to return the highly aberrated wavefront error (WFE) in these eyes to levels appropriate for the age and pupil size [26]. These lenses require a highly precise registration with the underlying WFE, involving both rotation and translation, where the tolerance decreases with an increasing aberration severity (e.g. for highly aberrated eyes the WFG lens may only shift less than 0.2mm or rotate less than 5° to retain above normal levels of visual image quality) [27]. This requires an exceptional stability that only few current lenses can provide.

Besides refractive corrections, there are also surgical solutions to KC. These include CXL, a widely used therapy that aims to slow down or even halt progression by increasing the corneal stiffness. It can provide stability for up to 15 years [28] and can be reapplied if needed. Although crosslinking cannot eliminate the large corneal deformations, it may occasionally flatten the cornea [29]. This flattening may be enhanced by customizing the treatment pattern to the patient’s corneal topography or corneal stiffness maps [30], but this option is not yet widely available and in the near future unlikely to return the cornea to normal optical function. Other surgical approaches attempt to smooth the anterior corneal surface by implanting corneal ring segments made of a polymer or an allogenic corneal material, or in more severe cases by a transplanting either the anterior corneal layers of the cornea or the entire cornea. Although surgical techniques can improve visual performance of keratoconic eyes, they rarely if ever provide age-appropriate levels of visual image quality [31] with a sphero-cylindrical correction.

Advances in science and technology to meet challenges

To optimize the WFG corrections, it is crucial to follow the ANSI guidelines [32] of using a fixed coordinate system with an origin at the pupil center for WFE measurements, aberrometer alignment, and scleral lens positioning over time and during manipulation. Moreover, to properly track eye rotation, the fixation point must be placed on the aberrometer’s optical axis, which must pass through the center of the dilated pupil while the patient looks at a fixation target [33]. These are current guidelines, but not always followed to the letter in current ocular aberrometers.

Next, it is essential to use metrics to assess the visual image quality, as the widely used total and higher order root-mean-square (RMS) WFE are not appropriate for this purpose for three reasons: (1) different aberrations with the same RMS impact vision differently (figure 2) [34]; (2) aberrations interact with each other to improve or decrease visual performance (figure 3) [35]; end (3) RMS only has meaning for the pupil diameter at which it was measured. To address this, alternatives metrics such as the visual Strehl ratio (VSX) were developed [36], which considers the neural processing and provides meaningful values with interesting attributes [31, 37, 38], while being independent of pupil size or RMS [38]. Regardless, new visual image quality metrics should be developed to better predict the various aspects of visual performance beyond high contrast visual acuity.

Figure 2.

Figure 2.

A 20/40 high contrast letter E aberrated by 0.25 µm of RMS wavefront error over a 6 mm diameter pupil for each individual Zernike aberration of the 2nd through 5th radial order. For defocus, 0.25 µm over a 6 mm pupil is equivalent to 0.19 D. Numbers in the red are values for the visual Strehl ratio (VSX) calculated in the spatial domain, varying between 0 (worst) and 1 (best). Notice that even though RMS WFE is the same for each simulation, image quality is different as also reflected in the VSX values.

Figure 3.

Figure 3.

The effect of 0.20 μm RMS of defocus (A), 0.15 μm RMS of spherical aberration (B) and the combination of the two producing 0.202+0.152=0.25μm of RMS (C) on a high contrast logMAR acuity chart. Notice that the image quality is worse in panels (A) and (B) than in (C), despite having a lower RMS.

These considerations demonstrate that the goal of WFG corrections on a highly aberrated eye should not be to drive the RMS WFE to zero, which is technically impossible and would take the image resolution beyond the sampling capacity of the foveolar cones [39]. Instead, one should optimize the visual image quality of that eye under the best sphero-cylindrical correction to match the eye’s neural processing capabilities for its largest physiological pupil diameter. This is done by bringing the VSX to within one standard deviation of the age-normal reference values of healthy eyes [27]. Setting clear goals for the correction and specifying a clear metric by which to assess its effectiveness will help avoid arbitrary approaches to WFG lenses. Furthermore, clear standards for the development and manufacturing should be drafted and updated on a regular basis to make WFG lenses a safe and affordable option to patients, while clinicians should be trained to the unique challenges of WFG lenses and the use of WFE data to show their patients the origins of their complaints.

Looking at customized crosslinking, the therapeutic may be improved by developing methods to map corneal weak spots using e.g. OCE and subsequently target those areas for treatment. Meanwhile, biomechanical models can help develop new treatment patterns to optimize the corneal flattening to facilitate sphero-cylindrical contact lens corrections and optimize long-term stability, while other algorithms could assess the risk of KC progression to identify those in need of crosslinking in the short term.

Alternative forms of correction could also be envisioned, such as a sphero-cylindrical contact lens that masks the regions with the highest WFE, WFG IOLs or adaptive optics spectacles that adapt to wherever the eye is looking.

Concluding remarks

The continued development of two currently existing technologies has the best chance to better address the visual needs of people with KC. The first, customized crosslinking combined with corneal elasticity mapping, will help stop the progression of the disease and perhaps reverse the corneal deformation to a minor degree. The second technology is, depending on the visual image quality, either sphero-cylindrical or wavefront guided (scleral) contact lenses to return the visual image quality to levels appropriate for that individual’s age and pupil size. To ensure WFG lenses find widespread adoption for patients that need them, it is essential to create standards for both manufacturers and clear and verified guidelines for clinicians to ensure that WFG lenses become a safe and affordable solution for patients to meets their visual needs.

4. Advancements in corneal imaging and elastography

Giuliano Scarcelli1 and J Bradley Randleman2

1University of Maryland, College Park, MD

2Cole Eye Institute, Cleveland OH

E-mail: scarc@umd.edu and RANDLEJ@ccf.org

Status

The cornea is the primary determinant of visual acuity, providing 70% of the eye’s total refractive power. Corneal power is determined by corneal morphology, which in the healthy eye exists in relative equilibrium within the mechanical balance between atmospheric pressure and IOP due to the stroma’s high collagen content and transverse lamellar collagen fiber structure. It is now widely recognized, from first principles, computational studies, and experimental measurements, that biomechanics drive corneal shape and thus visual acuity [4042].

Corneal biomechanics impact two intertwined issues of major clinical importance: KC and myopia. KC, a corneal disease characterized by progressive corneal warpage, results in vision loss, severely impacts quality of life, and its prevalence (2%–5%) is significantly higher than thought [43]. Myopia impacts ∼1.4 billion people worldwide, with prevalence expected to double, affecting more than 50% of the US population, by 2050 [44]. The economic burden of uncorrected refractive error is already substantial, with estimates exceeding $200 billion in productivity lost from >150 million persons with uncorrected refractive error [45].

KC progression can be stopped with CXL with minimal visual loss if detected early; however, insurance companies require morphologic proof of disease progression across sequential visits before authorizing treatment. CXL protocols offer modest improvement in visual acuity and impart risk for sight-threatening complications. Thus, early and accurate KC progression detection provides the greatest benefit to patients before vision is irreversibly compromised.

Laser vision correction (LVC) procedures (e.g. LASIK) effectively treat myopia, compares favorably to contact lens wear, and could help address the global burden of myopia; yet less than 10% of eligible patients undergo LVC, with most citing safety concerns as the major factor [46, 47]. Refractive surgery screening remains inherently conservative, as only morphological evaluations are currently available in the clinic; thus, many otherwise reasonable candidates are excluded from surgery due to the risk of developing postoperative ectasia, which continues to occur despite the utilization of multiple screening strategies including AI approaches [48].

For both KC and myopia, these challenges exist because, to date, despite major efforts to develop techniques to measure local corneal mechanical properties, current technologies have demonstrated low sensitivity to detect clinically-relevant features of ectasia susceptibility. The lack of effective biomechanical measurements has forced clinicians to rely on morphologic surrogates, e.g. curvature and thickness, which are insufficient to optimally identify KC before vision is compromised (see figure 4), screen at-risk surgical candidates [49], or predict treatment outcomes after LVC or CXL. Thus, the need to accurately identify the underlying corneal biomechanical profile that signifies corneal ectasia progression risk has never been greater.

Figure 4.

Figure 4.

Placido imaging of a patient without clear evidence of keratoconus in the right eye at their initial presentation in 2017 (upper left image) who suffered disease progression over the course of 1 year (bottom left image), with focal steepening of 4D and loss of visual acuity.

Current and future challenges

Intense efforts have been put forward to develop technology that measures corneal biomechanics in vivo. The only commercial device approved by the FDA for corneal biomechanical measurements, the ORA (Reichert, Inc.), quantifies one dimensional corneal deformation and recovery dynamics during corneal deformation by air puff, using a parameter called corneal hysteresis (CH). CH is a difference between the ingoing and outgoing pressures when the cornea becomes flat (at applanation) and represents viscous damping in the anterior segment. ORA metrics are reduced in KC in proportion to the KC severity. However, their sensitivity and specificity are insufficient to differentiate early KC from normal corneas [50].

The CST (Oculus, Inc.) combines air-puff induced deformation and a high-speed Scheimpflug camera to measure the mechanical response of the cornea. Dynamic OCT coupled with air-puff has also been evaluated. All of these techniques require sophisticated image analysis and numerical computation based on finite element analysis to solve an inverse problem that accounts for many variables beyond corneal elasticity. In addition, they are only sensitive to the global stiffness of the cornea and are unable to identify localized focal weakening [51].

Ultrasound techniques take advantage of different phenomena from air-puff mediated image analysis and thus allows local measurement of the elastic modulus of the tissue (at MHz frequency). However, ultrasound requires the excitation of relatively high-energy ultrasound via acoustic transducer and coupling gel. Although shear wave imaging by ultrasound is promising, further development and validations in vivo will be necessary to assess the potential of these techniques [52].

Advances in science and technology to meet challenges

Two optical elastography techniques have emerged in the research realm to address the challenges of this field: OCE and Brillouin microscopy [53, 54]. Optical coherence elastography takes advantage of the relationship between tissue stiffness and the speed of mechanical waves propagating in the tissue. The mechanical waves are usually launched via acoustic radiation force applied either via coupling gel or air-coupled; the speed of the wave is measured via OCT. Several ex vivo studies and in vivo studies in animals have demonstrated the potential of the technique; translation of this technology in vivo to the ophthalmology clinic is currently ongoing [55].

Brillouin microscopy is based on the interaction of incident light and thermal acoustic phonons in a sample. As a result of this interaction, the scattered light has a slightly different wavelength so that by measuring the difference in wavelength between incident and scattered light, one can extract the local longitudinal modulus of the tissue. Early prototypes of clinical instruments based on Brillouin microscopy demonstrated the ability to distinguish normal vs ectatic corneas [56]. However, Brillouin instruments based on early designs suffered from motion artifacts that hindered sensitivity for clinically-useful tasks such as early KC detection or the differentiation of LVC mechanical impact [57].

Recently, the next generation of Brillouin microscopes features co-located Optical coherence tomography to enable correction of motion artifacts [58]. The resulting high sensitivity provided the first demonstration of focal weakening in early and subclinical KC in vivo [59, 60]. Clear differences in regional Brillouin values were observed between the groups as demonstrated by significant differences for controls and both subclinical and early KC in several spatially resolved metrics with receiver operating characteristic (ROC) curves reaching an area under the receiver operating curve of 1. In early KC cases, Brillouin shift values performed better than traditional metrics such as maximum curvature (Kmax) and thinnest pachymetry. For eyes with subclinical KC that were not detectible using morphologic analysis via Scheimpflug tomography, motion-tracking Brillouin microscopy showed a clear focal weakening with a statistically significant reduction in minimum Brillouin shift. This is the first experimental evidence demonstrating metrics quantifying focal weakening in KC corneas that can reach or surpass clinical/morphological metrics (see figure 5).

Figure 5.

Figure 5.

Motion tracking (MT) Brillouin imaging showing regional differences between a normal cornea (Control) and an eye with subclinical keratoconus. MT Brillouin shift values are uniform across the normal control eye, while there is clear focal weakening in evident in the subclinical KC eye.

Concluding remarks

The field of corneal imaging and elastography is at a pivotal point; after decades where it has been recognized that biomechanics drive corneal shape and thus visual acuity, finally sensitive technologies to leverage mechanical measurements are coming into the clinic. At this stage, the first milestone has been demonstrated, i.e. the superiority of sensitive mechanical metrics over morphological ones for corneal diagnosis and management. The future needs a new leap in technology development to make elastography technologies user friendly, cost-effective, commercially available to facilitate wide adoption in clinical settings.

Acknowledgements

This work was supported in part by NIH Grants R01 EY028666, R01EY032537.

5. Structure and function relationship in the eye lens

Barbara K Pierścionek

Faculty of Health, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Bishops Hall Lane, Chelmsford, United Kingdom

E-mail: barbara.pierscionek@aru.ac.uk

Status

A third of the refractive power of the human eye for distance vision is provided by the eye lens. The lens is also able to change its shape, or accommodate, to enable the eye to focus over a range of distances. Accommodative capacity gradually decreases with age until the sixth decade of life whereupon the human eye is unable to focus on near objects. The lens has a lamellar structure with new layers of long thin fiber cells growing over existing tissue. There is no concomitant cellular loss which creates a structure that has the oldest cells in the center (nucleus) and the youngest in the periphery (figure 6). The distribution and concentration of proteins in the various layers of the lens varies increasing from the periphery of the lens to its center and hence creating a gradient of protein concentration which manifests as a gradient of refractive index [61]. This gradient index (GRIN) contributes to the superior degree of image quality in the lens. The changes in optical quality and accommodative capacity and their reduction with age are caused by alterations in the lens proteins. To date, these critical structure/function links are not understood and yet they are fundamental to an enhanced understanding and improved treatment of both presbyopia (loss of accommodative ability) and cataract (loss of transparency). The former is generally corrected with reading glasses; the latter necessitates surgical treatment to remove the cataractous lens and to replace it with an intraocular implant.

Figure 6.

Figure 6.

Diagrammatic representation of the eye lens showing the lens nucleus and cortical layers, designated according to the Oxford classification system [62]. The lens is enveloped in the capsule to which are attached zonular fibers. These fibers attach at their other ends to the ciliary body. The surrounding structures of the anterior eye are also shown. Acknowledgement is given to Dr Jesus Emmanuel Gomez Correa for creating the figure.

The major proteins in the lens are the crystallins [63] and these constitute around 35% of the lens wet weight. They are categorized based on biophysical and chemical properties and in the human lens are broadly identified as α, β and γ-crystallins [63]. These proteins are synthesized in the lens fiber cells and there is no loss of proteins throughout life. Hence, the ages of the proteins vary across the lens with the oldest proteins in the center and the youngest in the peripheral layers [61]. Changes in the proteins with time are thought to lead to alterations in their conformational structure and in their relationship with water, leading to more free water (unbound to protein) with age [64]. Some of these changes are thought to lead to protein aggregation and when this is sufficiently advanced, vision is impaired because of scatter and/or absorption of light, the lens loses transparency and the clinical diagnosis is cataract.

A further group of lenticular proteins that are much less common than the crystallins are the aquaporins, which are found in lens cell membranes and are responsible for transport of nutrients and water to the lens fiber cells. The function of these proteins is vital for a healthy microenvironment and for maintaining transparency.

Current and future challenges

Although it is accepted that the distribution and concentration of the different crystallin proteins creates the refractive index and that the aquaporins, or water channel proteins, play a role in water and nutrient transport, how changes in these proteins lead to loss of transparency and cataract remains uncertain. More insoluble protein is found in older than in younger lenses and this is further exacerbated in lenses with cataract [65]. The causal link between insoluble protein, protein aggregation and cataract formation may appear obvious but it should be noted that when analysis of proteins is conducted, this requires extraction of the proteins from the lens. It is possible that older proteins and those in lenses which have cataract are more vulnerable to insolubilization during the extraction procedure and may not necessarily be aggregating in the living lens. Indeed, a study on the Blue Eye Trevally fish lens found that although the lens was transparent, the amount of insoluble protein extracted was very high [reviewed in [61].

The relationship between the crystallins and water and how this relationship alters with age and cataract in the living lens is also uncertain. A proportion of water in the lens is bound to protein and a proportion is unbound or free water; the latter has been shown to increase with age [64]. The causal relationship of free water with age may or may not be indicative of cataract formation. However, unlike protein aggregation, free water can be measured in the living eye using magnetic resonance imaging. The technique has been erroneously promoted as a means to measure refractive index in the living eye but this is incorrect as refractive index depends on protein concentration and the amount of total water: bound and unbound [61].

The circulation of water and delivery of nutrients to the lens cells is thought to be dependent on a gradient of hydrostatic pressure involving aquaporin proteins [66]. Measurements of the developing zebrafish lenses indicate that the predominant aquaporin, aquaporin 0 plays a critical role on the formation of the refractive index gradient and hence is likely to contribute to the hydrostatic pressure gradient, maintaining a healthy physiological environment and consequently an undisturbed refractive index gradient and a transparent lens [67]. The precise nature of this structure/function relationship remains unknown.

Advances in science and technology to meet challenges

The greatest advance in understanding the lens structure/function relationship that is needed is in imaging and the development of technologies that can allow viewing of the major structural entities: the lens proteins, crystallins and aquaporins in the living lens. Great strides will be made even if such technologies were available for measurements in the in vitro intact lens. This would address the major and fundamental unknown aspect of protein behavior in the living, or at least in the intact lens. It would provide the answer to whether and how insoluble protein extracted from a lens is related to protein aggregation and/or other changes within the lens. This would lead to a far greater understanding of how the proteins and any changes to these proteins with age affect the refractive index gradient as well as what sorts of alterations to these structural entities may predispose to cataract.

Advances in optical measurements using synchrotron radiation and interferometric analysis have allowed accurate measurements of refractive index in very small developmental samples, both wild type and mutant [6769] (figure 7). This has led to leading research in the understanding of how the refractive index develops and changes with age in a range of species [67, 7072], which mutations affect the refractive index gradient and how this manifests as a disruption to the optics of the eye [67, 69, 73]. These measurements have also produced ground-breaking research in the testing of anti-cataract agents [74]. A translational of these capabilities into the living lens would greatly enhance advances in measurement of optics of the eye.

Figure 7.

Figure 7.

Three-dimensional refractive index plots for lenses of ARK mice from different ages: (a) 6 weeks, (b) 13 weeks, (c) 26 weeks, (d) 70 weeks. Reprinted from [14], Copyright (2024), with permission from Elsevier.

A further challenge lies in the understanding of how the aquaporin proteins fulfill their function of allowing water and nutrients to enter the inner lens and how this is maintained as the lens continues to grow. There may also be transient effects on water/nutrient transport when the lens changes shape during the process of accommodation. The importance of systemic nutrition and how this influences the health of the lens cannot be underestimated. The health of the lens is highly dependent on a balanced diet and there is a growing interest in certain foods, such as those rich in polyphenols, as potentially protecting the lens from opacification [75]. The relevance of diet to lens health and accurate monitoring of its effects on the lens presents both a challenge and an opportunity.

Concluding remarks

The lens is essentially a small sac of proteins and water contained within a semi-elastic membrane. The only pathology that is found in the lens is cataract and physiologically, the only ageing manifestation is a loss of capacity to focus on near objects. Yet, though structurally relatively simple, the lens is a sophisticated optical element that, to date, has been impossible to replicate in intraocular implants and the pathological and physiological changes continue to occupy scientific thought and endeavor. The key to understanding how the lens alters with age and what leads to cataract is a far greater knowledge of the behavior of the crystallin and aquaporin proteins and how this behavior affects function. The vast amount of research conducted on these proteins has required them to be extracted from their environment in the lens. How these proteins interact with other protein classes and with water within the intact living lens will require innovations in imaging technologies that do not currently exist. To develop such technologies is the greatest challenge for lens researchers in the future.

6. Lens models of the human eye

Jesús E Gómez-Correa and Sabino Chávez-Cerda

Instituto Nacional de Astrofísica, Óptica y Electrónica, Coordinación de Óptica, Tonantzintla Puebla 72840, Mexico

E-mail: jgomez@inaoep.mx and sabino@inaoep.mx

Status

A schematic eye is a mathematical or physical model that represents the fundamental optical properties of the real human eye. In essence, it is a simplified version of the eye, conceptualized as an optical system composed of two lenses: the cornea and the crystalline lens (or simply the lens) [76]. The lens is the most fascinating and complex optical element of the eye. This complexity stems from its nature as an asymmetric GRIN lens, where the refractive index decreases from the core to the surface. A remarkable property of the lens is its ability to alter both its shape and its GRIN distribution during the accommodation process, enabling it to focus effectively on objects at varying distances onto the retina. Thus, the lens is also dynamic [77]. Furthermore, the lens’s complexity is enhanced by its continuous growth throughout life, which causes its shape and GRIN distribution to change with age. In general terms, the lens is a dynamic and asymmetric GRIN lens that is age-dependent [78].

Over the last centuries, different lens models have been proposed and their accuracy and complexity have continued to evolve. Early lens models used simple spherical refractive surfaces with a constant refractive index [7982]. Some more recent models still focus solely on surface geometry [8385], but these surfaces are no longer spherical. Other models concentrate on representing the GRIN distribution [86, 87], where the refractive index varies throughout the lens. Additionally, more robust models incorporate the accommodation process and/or age dependence [8894]. These models can be mathematically represented by one or two functions due to the asymmetry of the lens. In the case of two functions, one represents the anterior part and the other the posterior part of the lens (see figure 8) [8992, 94, 95]. If a single function is used, it represents both parts [83, 84, 8688, 93]. For the GRIN distribution model with two functions, they must obey continuity conditions to ensure that the transition between them is smooth. The advantage of single-function models over others lies in the fact that they guarantee the smoothness of the refractive index profile of the lens throughout its entire volume without the need to impose boundary conditions.

Figure 8.

Figure 8.

The anterior and posterior surfaces of the crystalline lens, along with its gradient refractive index (GRIN) distribution. The GRIN smoothly transitions from a higher refractive index in the central nucleus to a lower index toward the peripheral cortex. The anterior and posterior surfaces exhibit different curvatures, contributing to the lens’s optical properties.

The crucial function of the crystalline lens in fine focusing during the accommodation process is achieved through changes in its shape and GRIN distribution (see figure 9) [61]. This ability is the result of an evolutionary process that has proven challenging to replicate in lens models. Most existing models of the crystalline lens treat its external shape independently of the refractive index and subsequently adjust imaging properties through optimization processes. One reason for this is that creating a model of the crystalline lens that simultaneously incorporates both parameters has been a formidable task. However, there are now two models that incorporate both parameters: the Poisson–Gauss lens model [88, 96] and the AVOCADO model [94].

Figure 9.

Figure 9.

Representation of the accommodation process in the human eye. The relaxed state (top) shows the ciliary muscle at rest, causing the lens to flatten for distant vision. In the accommodated state (bottom), the ciliary muscle contracts, allowing the lens to thicken and increase its curvature for near vision.

The Poisson–Gauss lens model: In 2020, Jaimes-Nájera et al proposed a physiologically realistic GRIN model of the crystalline lens based on a single function that accurately describes different accommodative states [88, 96]. This model provides the corresponding refractive index distribution and external shape of the lens capsule by adjusting a single parameter associated with the function of the ciliary body. Changes in equatorial and total axial lens thicknesses, as well as aberrations, were found to be within reported biometric data ranges.

The AVOCADO model: In 2016, Sheil and Goncharov introduced a new model that describes the age-dependent human lens using two independent axial and radial GRIN distributions [94]. Recognizing that the stability of the optimization process to match any proposed GRIN variation to experimental data directly depends on the degrees of freedom in the mathematical representation of the GRIN, the authors chose the lens’s external shape as a basis to constrain the GRIN distribution during optimization, thereby minimizing the number of free parameters. They demonstrated that the spherical aberration, calculated through exact ray tracing, aligns with experimental data.

Current and future challenges

Due to all properties of the lens, generating a model that encompasses all its characteristics is very challenging [78]. The primary challenge lies in modeling both the external and internal structures of the lens. These models must include the accommodation process and age dependence, providing realistic predictions of lens power and aberrations. Additionally, all parameters and their optical properties must be consistent with experimental measurements.

One of the major current and future challenges is fully understanding the modification of the GRIN structure and the lens capsule during the processes of accommodation and aging [97]. Achieving a comprehensive understanding of the lens in these contexts would lead to a better grasp of how the optical properties of the entire eye change, given that the lens is the most complex optical structure involved in both processes. The lack of thorough knowledge of these processes has, over the years, led to numerous efforts to develop models that accurately reproduce and explain all the changes in the GRIN structure of the lens during accommodation and aging [98, 99].

To obtain better models, more accurate in vivo measurements are necessary, which is challenging due to the lens’s position behind the iris, making direct measurements of its shape and optical properties difficult. Additionally, the intrinsic movement of the human eye complicates error-free measurements.

Most lens models are developed using averaged measurements of parameters and their optical properties. However, this also presents a challenge since these averages are typically derived from a population in a specific region, which may not accurately represent other populations. This raises the need for personalized measurements, paving the way for customized lens models tailored to individual needs [78]. However, some parameters cannot be obtained from a single measurement, so we must rely on existing literature, which often reflects averages from certain populations. These models derive their characteristics from source data that often combines clinical and experimental measurements obtained from human eyes. When such data cannot be practically or ethically collected from humans, animal-derived data may be used instead. Cadaver lenses can provide valuable insights into the effects of aging on the refractive index distribution—including its maximum value—as well as on lens geometry, specifically the lens volume and the ratio of anterior to posterior segments. However, the absence of zonular tension and the deformation introduced during dissection limit the accuracy of cadaver-based measurements. Consequently, modern in vivo imaging techniques now enable more precise assessments, offering improved characterization of the living eye for model development.

Advances in science and technology to meet challenges

Advancements in lens modeling largely depend on the development of clinical tools and software that can accurately measure key parameters, such as the surface geometry and refractive index distribution within the lens. However, these tools must be capable of measuring these parameters during the process of accommodation. This capability would lead to more accurate lens models and enhance our ability to predict how the optical properties of the lens change with accommodation and over time.

For instance, a deeper understanding of accommodation in these models could lead to the design of more advanced IOLs and other optical devices, such as contact lenses, that adapt more effectively to the human eye’s needs throughout life. Additionally, the ability to accurately model lens aging could open new avenues for early intervention before visual issues like presbyopia or cataracts arise, ultimately improving the quality of life in the aging population.

Another significant advancement lies in the evolution of AI, which has the potential to revolutionize the creation of more precise lens models. AI, with its ability to analyze large volumes of data and detect complex patterns, can significantly enhance the accuracy of lens models, enabling more detailed and realistic simulations of how the GRIN structure and lens capsule change during accommodation and aging.

Moreover, AI could streamline the generation of custom IOLs designs more efficiently. By utilizing machine learning algorithms, it would be possible to create lenses tailored specifically to the visual needs of each individual, taking into account factors such as unique ocular geometry and variations in accommodation response. This would not only optimize postoperative outcomes but also allow for unprecedented precision in addressing visual problems, ultimately improving patients’ quality of life.

Concluding remarks

In general, a deeper understanding of the processes of accommodation and aging will allow the development of more accurate lens models. These improved models, in turn, will lead to advances in the design of IOLs, which will translate into a better quality of life for people affected by lens-related conditions such as presbyopia and cataracts. With more precise models, we will be able to create more personalized and effective optical solutions, addressing visual problems more directly and efficiently.

Acknowledgements

This research was supported by Instituto Nacional de Astrofísica, Óptica y Electrónica (INAOE)

7. Ray tracing in the human eye lens

Alexander V Goncharov

School of Natural Sciences, University of Galway, Ireland

E-mail: alexander.goncharov@universityofgalway.ie

Status

Ray tracing in the human eye lens has its beginnings in the early study of optics, with foundational work by Johannes Kepler in the 17th century, who first described the eye as an optical instrument. Kepler’s insights into the role of the crystalline lens in focusing light on the retina influenced later scientists, including his contemporary René Descartes, and later Hermann von Helmholtz, who further developed the understanding of the eye’s optics, providing a theoretical basis for the study of accommodation and the development of corrective lenses. Helmholtz’s detailed exploration of light refraction through the eye, although not strictly ray tracing as we understand it today, paved the way for later advancements [100]. The emergence of computational ray tracing methods in the 20th century enabled increasingly accurate calculations of light paths through schematic models of the human eye, incorporating more realistic features such as aspheric surfaces and a GRIN lens. These methods transformed the way scientists predict the path of light as it traverses the eye, particularly within the complex GRIN structure of the crystalline lens.

Nowadays, ray tracing in the human eye lens is an invaluable tool in both research and clinical practice [78]. While paraxial ray tracing predicts optical power, image size, and its position, exact ray tracing allows for the estimation of ocular aberrations and their effects on vision quality in eyes with real (finite) pupil sizes. In the latter case, the main challenge is performing ray tracing in the GRIN lens, where light rays travel along curved trajectories, as shown in figure 10. Determining these trajectories usually requires numerical iterative methods [101, 102].

Figure 10.

Figure 10.

The curved ray paths in a quadratic GRIN lens, for which the refractive index at the lens surface is n0 = 1.37 and at the center nmax = 1.57, the large value nmax is chose to emphasize the ray bending effect in the lens.

Therefore, ray tracing is an essential for understanding the origin and impact of lens aberrations on both central and peripheral vision. It is also crucial for studying the effects of aging on lens shape and its internal GRIN profile (lens paradox) [103], the reduction in accommodation amplitude (presbyopia) [104], and overall image quality [78]. Ray tracing is also needed for developing customized methods of vision correction. These methods include the design of spectacle and contact lenses, IOLs, and the refinement of refractive surgeries like ray tracing-guided LASIK. As optical models of the eye become more sophisticated and realistic, assisted by exact ray tracing, they will enable the development of even more precise corrective lenses and surgical techniques, potentially allowing for fully personalized vision correction solutions.

Current and future challenges

Modern ray tracing techniques combine geometric optics with wavefront analysis, enabling highly detailed simulations of how light propagates through the eye. In particular, the error in the ray path within the lens should not exceed a fraction of the wavelength of the light used. Exact ray tracing can be easily performed at real heights and large incidence angles in conventional optical systems consisting of lenses with a constant refractive index. However, for eye models with a GRIN lens, exact ray tracing becomes approximate, requiring many iterations to achieve the same level of accuracy as in conventional lenses. For some existing eye models with a GRIN lens, it is possible to analytically calculate the paraxial properties of the lens, such as its power and back focal distance [105, 106]. However, performing ray tracing at finite heights analytically is only feasible for simpler models featuring a quadratic GRIN profile [107]. For more advanced lens models, numerical methods are required to solve a non-paraxial differential ray equation [102, 108].

Time-efficient finite ray tracing in GRIN media relies on various numerical methods, but these methods do not provide an analytical solution; at best, ray tracing in the reverse direction can yield the same residual error [109]. The absence of analytical methods prevents solving the inverse problem—namely, recovering the GRIN distribution of the lens given the incoming and outgoing light beams (or wavefronts) after they have passed through the lens. The challenge of reconstructing the lens using ocular tomography [110, 111] involves dealing with noisy experimental data and non-unique solutions to the problem, which may lead to unrealistic GRIN profiles [112]. Using layer-by-layer finite ray tracing through a lens with numerous constant refractive index shells can introduce some realism regarding discontinuities that may occur in the GRIN lens profile [113]. However, a lens model with a large number of shells that closely mimics the crystalline lens with a smooth GRIN profile still does not provide a solution to the inverse problem of lens reconstruction due to the sheer number of discreet refractions involved [114]. Ray trajectories with continuous refraction in future GRIN lens models might be describable semi-analytically, achieving sufficient accuracy while also enabling the solution of the inverse problem. Alternatively, one could apply brute-force optimization methods to obtain a solution, though it would heavily depend on the constraints and the choice of optimization variables in the model [115].

Advances in science and technology to meet challenges

The development of more accurate patient-specific models of the eye requires advances in optical methods for reconstructing eye parameters, particularly those of the lens. One of the important roles of ray tracing is to accurately analyze the optical properties of a given lens. However, a more challenging application is inferring the GRIN structure of the lens from experimental biometric data. This task is difficult in vitro [116] but becomes significantly more challenging in situ when reconstructing the optical system of a living eye.

In this context, fast and accurate ray tracing through the lens is essential not only for predicting how the image is formed on the retina (a forward problem) but also for imaging the lens itself, particularly its posterior part, which becomes distorted by the unknown GRIN structure (an inverse problem). This distortion effect must be considered when imaging the lens using OCT or Scheimpflug slit systems. These imaging techniques are not accurate enough to measure the lens shape with fraction-of-a-wavelength accuracy; at best, they can achieve a resolution of a few microns. However, they can still be useful for constraining the external lens shape and the shape of its nucleus. Measuring ocular aberrations across the visual field with wavefront sensing or laser ray tracing [117] ultimately provides a more accurate method for reconstructing the optics of the eye and lays the foundation for wavefront tomography. Additionally, measuring the optical path length (time of flight) in the eye will provide further constraints on the axial optical thickness and the eye’s overall length. An interesting alternative is to use OCT imaging at different off-axis angles [118].

The challenge of gathering biometric measurements in the living eye lies in the unavoidable changes that may occur if the measurements are done sequentially with some delay. Additionally, all measurements should be performed with instruments operating at the same wavelength; otherwise, chromatic effects might complicate the reconstruction process. Wavefront sensors operating across wide visual fields have already been used for retinal imaging systems assisted by adaptive optics.

However, integrating additional imaging modalities into a single instrument for wavefront sensing and simultaneously measurements that provide valuable constraints on the shape and position of the lens in the eye, remains to be done. Ultimately, this will enable researchers to capture more detailed information about the shape and optical characteristics of the crystalline lens, which in turn will allow for the development of more subject-specific eye models and potentially more efficient methods of ray tracing through a GRIN lens.

Concluding remarks

The most complex optical element in the eye is the crystalline lens, which features a GRIN structure that plays a crucial role in image formation on the retina. To analyze the imaging properties of the GRIN lens, numerical methods for ray tracing through the lens are employed. However, due to the lack of an analytical solution for ray trajectories in the GRIN medium, the inverse problem of reconstructing the lens in situ with current state-of-the-art imaging modalities remains unsolved, as the solution heavily depends on the GRIN lens model used. For future, more realistic patient-specific eye models—requiring fraction-of-a-wavelength accuracy for personalized vision correction—an integrated approach combining wavefront tomography and OCT imaging, assisted by efficient exact ray tracing, will be needed. If successful, this will enable the development of more customizable corrective lenses and surgical techniques for fully personalized vision correction.

Acknowledgements

Open access funding provided by Irish Research eLibrary. This research was also supported by the Hardiman Research Scholarship at the University of Galway, Ireland.

8. Photoreceptors of the human eye

Amy Fitzpatrick and Brian Vohnsen

Optics Group, School of Physics, University College Dublin, Beech Hill, Ireland

E-mail: Amy.Fitzpatrick1@ucdconnect.ie and Brian.Vohnsen@ucd.ie

Status

The color sensitivity of the human eye in photopic conditions originates in the 3 cone types of the retina that are most densely packed at the fovea. Here, the green and red sensitive M- and L-cones dominate with just a small fraction being blue sensitive S-cones (absent from the fovea centralis). In daylight conditions this combination results in a sensitivity peak at 555 nm wavelength. In turn, the rod photoreceptors, that have their peak density along a ring at an approximately 20° eccentricity, provide limited vision in scotopic conditions peaking at 498 nm wavelength [119]. The visual pigments are packed in lipid membrane infoldings in the outer segment of the cones and in stacked discs of the rods. Pigments renew at an approximately 2 week interval, with the oldest discs and pigments being shedded and engulfed by the dark retinal pigment epithelium (RPE) cells located just beyond the photoreceptors in the process of phagocytosis [120]. The photoreceptors absorb only a fraction of the incident light with the remainder largely absorbed by the RPE layer. Backscattering of light is very low, which is why the pupil appears as dark. Yet, advanced fundus imaging techniques, often with adaptive optics and infrared light, allow direct visualization of the cones and rods in the living eye.

Photoreceptors have long been considered to guide light due to a strong dependence on the angle of incidence for light at the retina [121, 122]. Nevertheless, there is evidence that the directionality may rather relate to the pointing and arrangement of the elongated cone cells in combination with a focusing effect by mitochondria in the ellipsoid [123, 124]. This explains the angular dependence of the Stiles–Crawford effect of the 1st kind [125127] as well as the perceived change in hue for oblique light known as the Stiles–Crawford effect of the 2nd kind [128, 129] without enforcing waveguiding. In this interpretation, both are consequences of leakage of light from the individual outer segments with potential crosstalk between adjacent cone photoreceptors. As a consequence of the Beer–Lambert absorption law, the fraction of light that triggers vision is proportional to the volumetric overlap between the light and the spatial distribution of the visual pigments [127]. This model also explains the lack of a Stiles–Crawford effect in scotopic conditions, as leakage of light from one rod, can be captured by opsins in a neighboring rod thereby flattening the angular response.

The detailed understanding of photoreceptors as an integral part of the optics of the eye may explain why each eye is best adapted to its own pattern of aberrations [130] as the photoreceptors will be oriented to maximize the optical path and volumetric overlap of light with pigments [127]. This opens up new ways for personalized optical corrections without prolonged adaptation periods. The temporal dynamics of photoreceptors at both short [131133] and long timescales [134136] are of significant interest. Photoreceptors react to light exposure changing the optical path length as explored with optoretinograms (ORGs) [131, 132] that may potentially be used as biomarker for disease and retinal change [133]. Fast ocular motion, drift, tremor and saccades play a direct role for our visual system at a sub-photoreceptor level [137, 138]. Further advancement in the field of photoreceptor optics and phototropism may hold the key to understanding adaptation to aberrations at the retinal level [127, 139141] prior to neural responses with vital new inputs into emmetropization and myopia prevention [136, 142, 143].

Current and future challenges

We have now detailed knowledge about the cone and rod photoreceptors in the adult eye as well as the impact of ageing and retinal disease, but our knowledge about retinal changes during childhood remains limited [143, 144]. Our knowledge about changes occurring to the photoreceptors over short [131133] and long timescales is also still sparse [134136]. From OCT, we know that photoreceptors respond to absorption of light by minute changes to the optical path (the integrated combination of length changes and refractive index alterations). This originates in the photoisomerism triggered by light absorption followed by slower osmotic swelling, but there are also small temporary photothermal changes caused by heating of the outer segment and the RPE cells. At a slower time scale, photoreceptors show a certain phototropism whereby they adapt their orientation and cytoskeleton over the course of approximately 2 weeks [134, 135]. The renewal of pigment layers in the outer segments will likely happen in such a way that cells maximize their light capture. Each visual pigment does not perceive an image, but only triggers by the detection of photons with the most efficient configuration when outer segments are pointed towards a common pupil point [145].

In the process of emmetropization and ocular growth in children, the cones and rods across the retina reshape and become denser likely linked to the optics of the anterior eye. As the absorption of light in each outer segment is limited to a fraction of the incident light, one may ask ‘why are outer segments not longer to capture more of the light?’ It is likely an optimization process of photon capture and visual acuity. Longer outer segments would secure higher photon capture but would also increase the likelihood of light leakage and crosstalk degrading vision. Ultimately, it would cause challenges for the cellular energy supply and the process of phagocytosis. It appears plausible that adaptation of the still developing photoreceptors in infants and children would be best matched to outdoor lighting conditions where the pupil is smallest helping to prevent myopia onset [136]. Evolution has prepared our eyes for outdoor life. Here, the pupil is small, and the risk of myopia onset is smaller. Clearly, photoreceptors should be understood as an integral part of the eye on par with the refractive properties of the anterior eye. If such knowledge can be used to find new methods to limit myopia onset and progression remains to be seen [142, 144]. Such insight may also help to understand how the eye adapts to refractive changes and thereby provide a better fit for subjective corrections from the moment new contact lenses or spectacle glasses are being worn for the first time.

Advances in science and technology to meet challenges

The past decades have witnessed impressive improvements in technological capabilities to image the retina and photoreceptors of the living eye. The development of OCT to visualize the individual layers across the retina and the use of adaptive optics to provide diffraction-limited transverse resolution at a cellular level have been vital ingredients for these achievements. We would still need more advanced imaging technology to visualize the internal structure of the cone and rod photoreceptors with higher precision, to learn where changes happen during ocular growth and where new refractive designs make a direct impact on the structure and function of the photoreceptors, for example, in myopia control. The development of high-resolution ORGs will likely be a key component to achieve this and will help us distinguish between true optical changes at the retina from that of neural origin.

In some of our work we use retinal simulators [146] from the microscopic to the macroscopic scale. One such example is shown in figure 11 where an array of test tubes with dyes are used to simulate the Stiles–Crawford effects of the 1st and 2nd kind with an effective directionality determined from the scattering of light incident at different angles based on the antenna model of the photoreceptors [123]. For oblique incidence, light leaks out of the test tubes before making it to the end, thereby mimicking the reduced sensitivity to oblique light. This is shown for a single test tube in the color-coded image in figure 11(b). We are also conducting novel research of light absorption in the photoreceptors using both ray optics and electromagnetic modeling as shown in figure 12. In this particular case, the simulation is two dimensional and includes 3 adjacent photoreceptors with light travelling from the left to the right. In the ray picture only the central cone is exposed to light from the pupil and some leakage can be observed in the outer segment. In the wave picture all three adjacent receptors are exposed to an incident plane wave and some focusing by the ellipsoid can be noted, as well as notes of higher intensity along the outer segment. Refractive indices are based on the literature [122] but can easily be modified. While we still need more details for the developing eye and retina in children, we have now at our disposal advanced modeling techniques that can be used to test hypotheses and optical corrections in numerical ocular and retina models, as well as with physical models of the eye and retina.

Figure 11.

Figure 11.

Macroscopic model of the foveal photoreceptor mosaic (a) with test tubes and food dyes to emulate the S, M and L cones of the human retina. The model is being used to (b) test the hypothesis of the Stiles–Crawford effects being mostly due to leakage of light.

Figure 12.

Figure 12.

Electromagnetic calculations of light leakage from 3 adjacent peripheral cones using (a) ray optics and (b) wave optics, respectively. Only the ideal case of on-axis incidence is shown, but the model is equally capable of analyzing oblique light incidence.

Concluding remarks

The journey towards understanding the optics of photoreceptors has been long and complex. Although a directionality in the light transmission was recognized early on, it was the discovery of the Stiles–Crawford effect that triggered a range of experiments aimed at understanding how vision responds when light is obliquely incident onto the retina. The focus was on Maxwellian illumination which may have delayed the discovery of a substantially stronger apodization by the integrated Stiles–Crawford effect in normal viewing conditions [127, 139, 140]. As we understand the optics of the retina better, it has become clear that not only does the retina and visual pigments adapt to changes in illumination at both fast and slow time scales [131136] but equally it plays an important role for the overall ocular optics in line with the refractive optics of the anterior eye. With this knowledge, we expect that future ophthalmic products may use this to support improved and personalized vision aids, and ultimately lead to new diagnostic tools for earlier detection of vision loss. New retinal implants to restore vision for the blind could utilize this by emulating the optics of the photoreceptors.

Acknowledgements

This research has been realized with financial support from the UCD SIRAT scheme and H2020 ITN MyFUN Grant Agreement No. 675137.

9. Retinal imaging: where we are and where we are going

Jessica I W Morgan

Scheie Eye Institute, Department of Ophthalmology, University of Pennsylvania, Philadelphia, PA, United States of America

Center for Advanced Retinal and Ocular Therapeutics, University of Pennsylvania, Philadelphia, PA, United States of America

E-mail: jwmorgan@pennmedicine.upenn.edu

Status

Retinal imaging has long been an important part of the ophthalmic exam as it allows visualization and documentation of retinal phenotypes that aid in the diagnosis, prognosis and treatment of ophthalmic diseases including age-related macular degeneration, glaucoma, diabetic retinopathy, and inherited retinal dystrophies [147]. Imaging in the eye has also served as a technique to visualize disease in the vascular and neurological systems, as changes in the retina have been observed in conditions of hypertension, diabetes, dementia and Alzheimer’s disease among other systemic and neurological diseases [148150].

Numerous technologies abound for retinal imaging, many of which are now considered standard care in ophthalmic practice, others of which are considered advanced tools used only in specialized cases or research settings. The following paragraph provides a general overview of the most commonly used techniques for retinal imaging, but broadly speaking, any imaging technologies employed in microscopy can been applied to retinal imaging, where the natural optics of the eye serves as the objective lens of the microscope. The historical gold standard is fundus flash photography which provides a color view of the macula, optic disk, and retinal vasculature [151] (figure 13, top left). Scanning laser ophthalmoscopy (or line scan ophthalmoscopy) employs a light source that is focused on the retina which is then physically moved across the retina to enable en face video-rate imaging of the scanned area [152]. An advantage of scanning laser ophthalmoscopy is that the light returning from the retina can be collected through a confocal aperture thereby reducing scattering from the ocular media. A disadvantage however, is that any eye motion that occurs during the scanning acquisition will cause distortions within the obtained retinal image. More recently, OCT is a technique arising from interferometry that provides cross-sectional volumetric imaging of the retina [153] (figure 13, top right). A major advantage of OCT is its high resolution in the axial direction, which enables visualization of the retinal lamination. Methods for enhancing the contrast of retinal features, such as fluorescence or motion contrast, are also available [151]. Fluorescence techniques in combination with fundus photography or scanning ophthalmoscopy enable visualization of intrinsic retinal fluorophores such as lipofuscin and melanin in the RPE or extrinsic fluorophores delivered to the eye via the vasculature such as fluorescein and indocyanine green. Motion contrast methods, such as OCT-angiography involve the comparison of multiple sequentially acquired images, where any differences between consecutive images are attributed to blood flow. Each of these techniques provide complementary visualizations of the retinal phenotype and inform clinicians about the health of the retina under examination.

Figure 13.

Figure 13.

Color fundus photograph (top left) of the normal macula, cross-sectional OCT b-scan through the fovea (top right) at the location marked by the black line in the fundus photograph, and adaptive optics images of the photoreceptor inner segment and outer segment waveguided mosaics (bottom) at the numbered locations marked in the fundus photography.

Retinal imaging through the natural optics of the eye however, is limited by both the size of the pupil and the quality of the eye’s optics. Diffraction theory would suggest that as the pupil gets larger the resolution of the system would improve. However, as the size of the pupil increases, so too do the eye’s optical aberrations. Adaptive optics (AOs) is a tool for first measuring and then compensating for the eye’s optical aberrations [154]. This technique enables diffraction limited resolution even when the eye’s pupil is fully dilated. AO has been combined with fundus photography [154], scanning laser/light ophthalmoscopy [155], OCT [156], fluorescence imaging [157], and motion contrast [158] among other imaging technologies. With these techniques, investigators have been able to visualize individual cells within the living retina including the cones and rods within the photoreceptor mosaic (figure 13, bottom), the RPE, ganglion cells, individual white and red blood cells, and macrophages among others [147].

The vast majority of retinal imaging is used to inspect the structure of the retina in health or disease. Recent techniques however have enabled investigations into the function of observed structures. Like structural imaging there are multiple complementary techniques for investigating function, including methods which incorporate subjective responses of perception such as perimetry or acuity [159], or physiological measures such as blood flow. A new, rapidly emerging field includes optoretinography, which involves measurement of an optical signal originating in the retina in response to a visible stimulus. Most studies in this field to date have investigated the ORG of photoreceptors [160, 161], though similar experiments have targeted measurements of bipolar and ganglion cells [162]. Current theory suggests the phase of light reflected from cell surfaces/interfaces is altered following light exposure by both contraction and expansion of the cell’s membrane and that these changes correlate with mechanisms involved with phototransduction in the photoreceptors or activation of inner retinal neurons [131, 163]. Though it is still a new technique, optoretinography has demonstrated strong potential for high resolution, noninvasive, objective measurements of physiological cell function in the living retina [164, 165].

Clinical trials investigating experimental therapeutic approaches usually are required to demonstrate a functional benefit for the trial to be considered successful. In some cases, structural results from retinal imaging may be used as the trial’s primary outcome measure, in particular if the structural phenotype being used is known to correlate with better vision. Examples of structural phenotypes that correlate with vision include the extent of the ellipsoid zone (one of the retinal layers observed on OCT attributed to photoreceptors) or the extent of geographic atrophy (visualized as a loss of autofluorescence attributed with loss of the RPE). Studies which strive to understand structure–function relationships therefore are crucial for interpreting the disease phenotypes observed on images and will continue to be important for identifying structural measurements that are appropriate for use as outcome measures in clinical trials.

Current and future challenges

Retinal imaging is playing an increasingly important role in clinical care, yet there are still numerous challenges to overcome. For one thing, imaging in elderly patients or patients with disease usually is more difficult than imaging in young, healthy controls. Patients many times have abnormal eye movements that can reduce the success rate of imaging and lengthen the time spent acquiring images. Further, patients may have abnormal optics, cloudy media, or cataracts which hinder imaging. In addition, the structures under investigation may show abnormalities which may make the interpretation of findings more difficult. This is further complicated by the first date of presentation for many individuals. Indeed, many times irreversible vision loss has already occurred when a patient presents for initial imaging. This begs the question of whether retinal imaging should become a part of standard preventative medical care and if so, using what modalities and at what age(s)?

The time spent on data acquisition and analysis is also a major limiting factor for multimodal retinal imaging. High resolution multi-modal imaging typically requires pupil dilation and access to multiple different imaging devices, resulting in extended appointments for patients. In addition, quantitative analysis is a burdensome task as reading or annotating images requires significant time by trained individuals and therefore most analysis takes place in a post-processing environment. These problems highlight the need for validated, automated algorithms capable of extracting relevant biomarkers in real time and ideally early in disease processes when intervention is more likely to succeed. Collaborative teams including engineers, scientists, and clinicians will be needed to identify the most successful techniques and approaches for these problems.

Advances in science and technology to meet challenges

With sufficient attention and resources solutions to these issues will be found. Already, normative databases of multi-modal retinal images are becoming available. Large databases of structural and functional imaging results that take into consideration variations in age, sex, and ethnicity will be needed to affirm differences between control and disease features and provide testing grounds for new algorithms, including those developed using machine learning and AI approaches, to identify biomarkers of disease. To be most impactful, future studies should take an active approach to data sharing by providing access to images for broad use and algorithm development.

Improvements in image acquisition, such as eye/motion tracking and real-time registration also are under development to enable better, faster acquisition in challenging patient populations. These technical improvements will also aid in expediting studies to develop functional applications of retinal imaging such as optoretingraphy.

Concluding remarks

As a practical matter, the structure and economics of clinical trials and medical care puts a high value on biomarkers that reveal positive effect or lack thereof reasonably soon after application of therapy. Such biomarkers are best formulated in the context of the most precise possible characterizations of disease progression. To this end, retinal imaging has provided quantitative tools for objective, noninvasive assessment of retinal structure and function in both health and disease. Thus, high resolution retinal imaging shows high potential to impact our understanding of disease mechanisms, progression, and treatment efficacy. Its importance in ophthalmic and systemic medical care will only continue to grow in years to come.

Acknowledgements

Funding provided by: National Institutes of Health (NIH R01EY028601, P30EY001583), F M Kirby Foundation, Research to Prevent Blindness.

10. State of the art of adaptive optics for evaluating retinal structure and function and healthy and diseased eyes

Austin Roorda

Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, Berkeley, CA 94720-2020

E-mail: aroorda@berkeley.edu

Status

The saying ‘there is no substitute for good optics’ applies to many fields—astronomy, photography, microscopy, and refractive corrections—but the field of ophthalmoscopy may make the strongest case. The eye optics is generally well-adapted for normal human vision, but ocular imperfections prevent imaging and optical interrogation of the visual system on a cellular level. AOs is a set of tools to measure and correct these imperfections and overcome these limits as shown schematically in figure 14. AO technologies have been used effectively in ophthalmoscopes since 1996 [154] and have enabled dozens of revelations and discoveries in healthy and diseased eyes [166168]. AO has proven to be an effective technology for many ophthalmic imaging modalities including full-field [154], scanning light imaging [155] and OCT [156].

Figure 14.

Figure 14.

Generic schematic of an AO system for the eye with a list of all the known imaging and vision testing modalities that will benefit.

AO is useful because it enables near-diffraction-limited focusing through the eye’s largest pupil size (highest numerical aperture) both on the way in and out of the eye. For large pupils, the diffraction-limited focused spot is on the order of single retinal cells and this level of access has driven a paradigm shift in how ophthalmoscopes are used to study vision in healthy and diseased eyes, effectively turning an ophthalmoscope into a microscope. And, like a microscope, there seems to be no limit in the arsenal of imaging methods and modalities that the use of AO will complement. Through the use of multiple AO-assisted techniques, nearly all retinal cell classes have been imaged in vivo, mostly in humans but also in animal models as shown in figure 15.

Figure 15.

Figure 15.

Selected images from AO systems. (A) AOSLO image of rods and cones using annular illumination like that described in [181] (courtesy of Johnny Tam, NEI). Reproduced with permission from Johnny Tam. (B) AOSLO phase contrast (split detector) image of the cone mosaic taken using methods described in [182] (courtesy of Jessica Wong and Jacque Duncan, University of California, San Francisco). Reproduced with permission from Jacque Duncan. (C) AOSLO fluorescence imaging of the RPE mosaic using indocyanine green fluorescent dye [183] (courtesy of Johnny Tam, National Eye Institute). Reproduced with permission from Johnny Tam. (D) AOSLO phase contrast images of immune cells in a mouse retina. Reproduced from [179]. CC BY 4.0. (E) AO-OCT images of retinal ganglion cells collected using methods described in [167] (courtesy of Donald T. Miller and Kazuhiro Kurokawa, Indiana University). Reproduced with permission from Donald T Miller. (F) False-color image of the human trichromatic cone mosaic determined using optoretinography in a phase-resolved line-scanning AO-OCT system [184] (courtesy of Ramkumar Sabesan, University of Washington). Reproduced from [184]. CC BY 4.0. (G) AOSLO fluorescence image of a mouse retinal ganglion cells. Adapted with permission from [185] © Optica Publishing Group. (H) AOSLO microperimetry showing retinal function inside and outside lesions resulting from an accidental laser exposure as described in [186]. Higher dB scores indicate greater sensitivity. Scale bars in every panel is approximately 50 micrometers. Reproduced with permission from [186]. © 2023 American Academy of Optometry.

Laws of optical reversibility also mean that an AO correction is equally effective for light entering and exiting the eye. So, in addition to correcting light coming out of the eye to image structure, AO can be used to correct light going into the eye to test vision with diffraction-limited optics or with specific optical manipulations (e.g. adding aberration for increased depth of focus) [169] or to measure function on a cellular scale [170]. Importantly, systems that combine imaging and vision testing can be used to make direct relations between structure and function on that scale [159] in both healthy [170] and diseased eyes [171]. Functional testing falls into two classes, subjective and objective. Subjective tests include forms of microperimetry and visual acuity testing. Objective tests take multiple forms. Noninvasive approaches include the emerging field of ORG for which the optical coherence-based techniques are the most advanced, providing an entirely new way to classify cone types [172] and see individual cone dysfunction in eye disease [164].

Current and future challenges

So how do we benefit from a microscope for the human eye? Initial discoveries enabled by AO were primarily structural: cone density in the fovea [173, 174], the packing arrangement of the three cone types [166], direct measures of cone structure for specific mutations [175], and microvascular structure [176]. But the biggest benefits will come from instruments that elucidate the retinal function in healthy and diseased eyes. A range of functional testing has already been done: measurement of the products of the visual cycle [177], blood flow in response to light stimulation [178], photoreceptor changes in response to light stimulation (ORG) [172], immune cell responses to retinal injury [179] and ganglion cell functional classification using activity-dependent fluorescent labels [180]. It is in these areas that AO will make its largest impact. This is especially true in light of new treatments for eye diseases that are available today and are on the horizon. Having a tool that can evaluate retinal status prior to gene therapy, or the integration of stem cells in the host retina, or the functional benefits of treatments for retinal degeneration are essential. To do this accurately and quickly will help to accelerate treatments for eye disease. An even greater impact might be in early detection and diagnosis of disease, although that is a more difficult and daunting task than originally thought.

In the continued effort to relate structure to function in healthy and diseased eyes AO will continue to have a crucial role, even as the imaging modalities themselves will continue to evolve. For example, the notion that optical coherence-based methods could be used to reliably measure nm-scale change in cone outer segment length to light stimulation was largely unanticipated in the early days of AO and OCT. The incorporation of AO into OCT enabled the classification the three cone types with more accuracy and in a shorter time than any previous approaches [172]. It is interesting to think of what new approaches are beyond the horizon.

Advances in science and technology to meet challenges

We are approaching 30 years since AO was first demonstrated for the eye, but it often feels like the technology is still in its infancy. Most AO systems are still custom-built by researchers and few companies have taken on the task of commercializing AO instruments and making systems more mainstream. The resolution benefits of correcting aberrations are unquestionable, so why is it not widely used? There are several reasons: First, the highest performance AO systems remain cumbersome, expensive and difficult to operate in comparison with other ophthalmic instrumentation. Second, the biggest benefits are realized for the largest pupil sizes (highest numerical aperture), but large pupils are also the most challenging to correct with AO. Third, the biggest benefits and most robust operation are for clear media. Collectively, these limits affect the ability to use AO to image the diseased or the ageing population who may have greater fixational eye movements, nystagmus, smaller pupils, more turbid media or IOLs. In other words, the population that benefits the most are the most difficult to study. Finally, AO offers a microscopic view, which is an unprecedented scale for an ophthalmoscope. The scientific benefits are clear, but the immediate clinical usefulness is not. Until there is something learned from the microscopic view of a patient’s retina that will inform a clinician on the course of treatment, the widespread need to have an AO device may always be low. This is further complicated by the fact that a consequence of the microscopic view is that the image field sizes are often small, in the opposite direction of many efforts in ophthalmoscopy to image an ever-wider field.

Despite these challenges, there is much scope for advances in technology that will make AO systems easier to use and more robust for a wide population. As those developments happen, the slope of the learning curve will steepen. With massive amounts of data on normal and diseased eyes, the ability to diagnose and track progression of a disease will continue to accelerate.

Concluding remarks

The advantages of in vivo microscopy are clear and AO in its current form or whatever future form it may take will continue to be the best technology to achieve that.

Over the past 30 years, those in the field have learned how to leverage AO in multiple modalities to image most cell classes in the retina, resolve dynamic functional processes, and explore vision on a cellular scale. Many discoveries have already been made, but the field is poised to make many more in healthy and diseased eyes.

Acknowledgements

Support from NIH Grant: R01EY023591

11. Schematic models of the human eye

Jos J Rozema1,2 and David A Atchison3

1Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium

2Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium

3Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Australia

E-mail: jos.rozema@uantwerp.be and d.atchison@qut.edu.au

Status

Optical models of the human eye have been used to provide a framework for explaining optical phenomena in vision, predicting how refraction and aberrations are affected by change in ocular biometry and exploring optical limitations to vision. One category is the ‘toy train’ type, a working tool that mimics the behavior of real eyes but does not always attempt to be anatomically or mechanistically accurate. Schematic eyes fit into this type and can be described as mathematical entities that provide analytical descriptions of the eye’s optical behavior. Applications of schematic eyes include [76]: retinal image size calculations; predictions of refractive errors arising from variations or changes in eye dimensions; IOLs power following cataract surgery; aberrations and retinal image quality with or without optical or surgical intervention; designing spectacles, contact lenses, IOLs and corneal refractive surgery; and can be incorporated into the design of imaging instruments.

The simplest models are reduced eyes with a single refracting surface at the front of the eye. These are followed by simplified eyes with three refracting surfaces, one for the cornea and two for the lens, and then by four refracting surface models with two corneal and two lenticular surfaces. Next, allowance can be made for the gradient nature of the lens, first by nested shells with increasing refractive index towards the center of the lens and then by true GRIN modeling. Distinction can be made between paraxial models and finite models. The former give accurate predictions of retinal image quality only for small pupils and for objects close to the optical axis. The latter are designed to improve predictions of optical quality both on and off-axis with the incorporation of media chromatic dispersions, by surface toricities, asphericities, tilts and decentrations, and by a curved retina.

Most schematic eyes to date represent population averages, with some developed for different situations or stratified by age, gender, ethnicity, refractive error, and accommodation. These models take their characteristics from their source data, which is often a combination of clinical and experimental data in humans, but may in some cases be based on animal data in case human cannot be obtained in a practical or ethical way. With the increasing availability of clinical instruments to measure ocular biometry, there is a move towards customization [187] that will be beneficial for refractive surgery applications and predicting the development of myopia at an individual level. Furthermore, we envisage a move towards more holistic models of wider appeal, involving not only optics but mechanical and other aspects of the eye and vision.

Current and future challenges

Although a wide variety of eye models has been published in the literature, most correspond to idealized averages of the biometry found in certain (sub)populations. Given the large biometric variations between individuals, such a one size fits all approach is clearly insufficient to produce a description that is inclusive for all eyes. Whether this is problematic depends entirely on the problem that the model is supposed to address. For the development of new optical solutions for, for example, myopia control, interindividual biometry variations are likely unimportant as the correction addresses the refractive error, which can be measured and corrected with great accuracy. When used in optical calculations, on the other hand, this issue may lead to greater problems as inaccuracies will compound and increase in magnitude the more the biometry of an eye deviates from those of the model being considered. A clear example of this is IOLs power calculation that is known to be inaccurate for eyes that are either too long or too short [188]. While this has prompted the development of new IOL calculation formulas dedicated to such cases [189], one may argue that more accurate eye models can lead to IOL formulas that are robust to any biometric combination.

Concerns such as these led to the development of customized models which integrate clinically measured data of a patient into a predefined structure, creating a hybrid model that is considerably closer to the original eye. But as not all parameters can be measured clinically and are taken from the generic predefined structure instead, some correlations between biometric parameters may be lost. This leaves room for further improvement.

An alternative approach is generative eye models, algorithms able to produce an unlimited amount of random, but plausible biometric data with the interindividual biometric variations found in the general population. Examples are the widely used wavefront model by Thibos et al [190] and the more recent SyntEyes models [191, 192]. Although these are currently not fully customizable to a patient’s biometry, the output of generative modeling can be used in batch processing to e.g. assess the performance of new optical solutions in a wide biometric range.

Despite these advances, there are still important limitations to the realism of current descriptions as most models are purely optical and do not include other influences, such as mechanical pressure reshaping the eye globe or crystalline lens.

Advances in science and technology to meet challenges

The most important technological aspect that that can improve the accuracy of existing eye models lies in the development of clinical equipment and software to determine the ocular biometry more accurately, as well as new devices to measure currently difficult to obtain parameters such as the surface shape and GRIN of the crystalline lens, the shape of the retina and the refractive indices within the eye. Other potential improvements lie in reliable methods to measure the accommodative response, taken concurrently with biometry measurements, allowing more accurate accommodative models [193].

Besides improvements in the input data, there are many conceptual improvements to be considered as well, such as the influence of the mechanical properties on the ocular structures. As the eye is a physical structure, it is susceptible to stress caused by internal and external forces that lead to geometric deformations. But while there are many papers on mechanical eye models in the literature, these often do not consider the optical aspects, much as most optical models do not consider the biomechanical aspects. Combining both more often would be ideal, but this is hindered by the high computational cost of the finite element analysis software needed for the biomechanical calculations. As developers are working to reduce these costs using AI, this issue should eventually disappear.

Another advance is the development of models that describe the growth and refractive development of the eye [194], starting from an initial biometry state, such as at birth, and letting the eye grow virtually to adulthood under various behavioral and external influences. While interesting to study e.g. myopia development, current forms of such models contain only a minimal number of descriptive parameters and are based on literature until the 1990s. Further development by including more biometric parameters and the response of the various retinal layers and the choroid [195] can benefit the conception of new methods for myopia control.

Once such methods and models become available, clinical biometry data can be combined into an opto-biomechanical virtual twin of a patient’s eye that can be used to try out refractive or surgical solutions virtually before performing them for real. Alternatively, one could perform virtual clinical trials of new techniques using either real or generated biometry data, which could form an intermediate step between animal testing and testing in the first group of real patients, thus providing an extra opportunity to identify issues beforehand.

Concluding remarks

Beyond the current schematic eyes, which are mostly restricted to optics, a worthwhile goal is to develop a holistic (all-in-one) model that combines optics, mechanics and neural aspects. Some such models could also consider eye growth under various behavioral and environmental conditions. While complex, this could help address issues that involve many disciplines, such as to gain better understanding about accommodation or refractive development. Clinically, the development of virtual twins could help further personalize eye care, while generative models and virtual trials could become essential tools in the development of new surgical and refractive solutions.

Notwithstanding the above, it is generally best not to overcomplicate matters, but to critically consider the parameters and features to be included as often the simplest model to address a particular issue is best.

12. Modeling of ocular surfaces using different sets of functions

Juan P Trevino1,2 and Alejandra Consejo3

1Universidad Politécnica de Puebla, Cuanalá Puebla 72640, Mexico

2Tecnológico de Monterrey, Mexico

3Aragon Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain

E-mail: juan.trevino306@uppuebla.edu.mx, jptrevino@tec.mx and alejandra.consejo@unizar.es

Status

The interfaces among the optical elements of the eye predominantly determine the optics of the eye, for this reason modeling the surfaces of ocular refractive elements been a one of the main tasks in ophthalmic optics. Efforts can be traced back beyond Gullstrand and LeGrand [196] who modeled the eye mainly considering spherical surfaces and the refraction indices within the eye. We may consider the most relevant surfaces to be the outer and inner surfaces of the cornea and crystalline lens. Although the latter is a graded index element, it has been often considered as a multilayered element [197, 198]. In figure 16 the simplest surface model can be observed. Different sets of mathematical functions can be used to model these ocular surfaces, and their properties and suitability for surface representation will be discussed in the following. However, it is important to clarify that the same types of functions—particularly those with orthogonality and completeness—can also be applied to describe the wave nature of light as it travels through the eye, including the wave aberration function, the point spread function (PSF), and the modulation transfer function. These optical descriptors are fundamental in clinical and research contexts but do not represent physical surfaces.

Figure 16.

Figure 16.

The four-surface model of the human eye. The diagram corresponds to spherical surfaces with typical curvature radii: the anterior and posterior surfaces of the cornea, and the anterior and posterior surfaces of the crystalline lens.

Basic surface modeling consists of fitting continuous functions to target surfaces, which are expanded as a combination of orthogonal functions [199201]: z(x,y)=mkcmΦm(x,y)+ϵk(x,y) where coefficients cm represent the weight of each basic function Φm(x,y), and the completeness of orthogonal sets guarantees that the error ϵk decreases as the number k of terms increases. The coefficients are orthogonal projections of the target onto the ‘direction’ of each basic function and are calculated as definite integrals within the domain of the target surface. The behavior of the basic functions at the boundary of a disk-shaped domain plays a special role in modeling since it might help representing certain features of the target surface. Also, for sampled surfaces, orthogonality is lost, and the mathematics become that of finite-dimensional linear algebra. While Zernike, Nijboer, Bhatia and Wolf introduced the original Zernike polynomials (see [200] and references therein), the underlying theory left room for exploring several other sets of functions with the key properties of orthogonality and completeness. Among these sets we find polynomials (finite number of terms of powers of the space variables), like Chebyshev, Jacobi, and Zernike polynomials and special functions which can be defined as infinite sums, like Laguerre, Bessel and the Hypergeometric functions [202]. The Zernike polynomials had gained preference of use because for their close relation to classical or Seidel aberrations [200], however, they have been also applied for topographic characterization (i.e. the physical geometry of optical surfaces). For this application, shortcomings appear for certain complex cases such as combined surfaces (cornea-limbus-sclera) or membrane deformable mirrors [202, 203]. For these special cases, other orthogonal sets have been also shown to be suitable depending on surface features [109, 199201, 204]. Figure 17 presents the classical Zernike functions along with the Bessel Circular functions where certain values of the azimuthal order have been selected for visualization purposes.

Figure 17.

Figure 17.

A sample of circular orthogonal functions. To the right, the Bessel circular functions are shown along with the ordering proposed according to Trevino et al and organized in terms of azimuthal and radial indices. To the left, the classical Zernike circular polynomials are arranged according to radial and azimuthal indices.

The anterior corneal surface is mainly modeled for determining KC or for contact lenses fitting among other applications. Zernike decomposition of corneal height data had been proposed by Babcock [205]. However, it was Noll [206] who introduced them for wavefront correction, and Schwiegerling and Greivenkamp [207] who launched the Zernike set to be the current standard. Orthogonality of Zernike and related sets is usually defined within a continuous domain, such as the unit disk, corneal topographers based on Placido rings [208, 209], produce discrete samples of the corneal data and orthogonality is lost. Efforts were done to overcome this shortcoming by rearranging the sampling distribution, and finally settled by finding the optimal number of samples and amount of Zernike terms needed to represent the cornea with sufficient accuracy [210].

Current and future challenges

There are several applications involving both optical and phase surfaces, for which Zernike polynomials are not optimal. Surfaces like corneal and crystalline lens surfaces, deformable mirrors on the one hand, and phase functions as the aberration function or the influence functions of deformable mirrors on the other hand, are a few examples.

Although the crystalline lens is a continuous element with variable refraction index (GRIN medium) [103], it has been modeled as a four-surface element and, the latter provides good insight into its optical properties. The main crystalline lens surfaces may be, of course, represented as a finite series of orthogonal functions. IOLs characterization [192] is another problem where surface modeling is relevant to enable characterization of their profile and optical properties. Not only determining the best fit given a certain orthogonal set is a problem, but selecting the set that best represents the surfaces is important. Rogel et al [199] experimented with several different sets of functions and found that the choice depends on specific features of the target surfaces, which opens the opportunity to test different functions to this complex surfaces. A similar idea applies for machine learning, there have been different approaches where the mail goal is to determine the best set of descriptors might be for pre-screening purposes [211, 212].

AOs involves retrieving and correcting the phase aberration of the human eye. The retrieval is frequently done using a Hartman–Shack wavefront sensor while the correction is usually done by tuning a deformable mirror. The deformation is attained by shifting actuators to provide the required deformation. Each actuator provides a specific deformation to the mirror’s surface. The calibration usually requires a combination of actuators to provide specific Zernike combinations. Although the Zernike polynomials are often used to represent both mirror surface and wavefront aberration, it has been discussed how other sets of functions, or even a combination of functions may be better suited for adaptive optics.

Finally, the peripheral aberrations are measured at angles where the pupil image is seen as an ellipse, and the Zernike polynomials lose the orthogonality property in this domain. There are ways to build orthogonal sets at such conditions taking the original set as a departure point. This process is the Gramm–Schmidt (GS) orthogonalization process [201, 213], however there are sets which are naturally orthogonal in the elliptical domain. The natural candidate are the Mathieu functions which are fixed at the boundary, while the Zernikes are free at the boundary which is better suited for this particular problem, so other solutions, such as GS orthogonalization has been applied (see [200] and references therein).

Advances in science and technology to meet challenges

Optical modeling has become a cornerstone in addressing the complex challenges faced in modern ophthalmic research and technology. In this context, modeling topographical surfaces such as front and back corneal and lens surfaces, plays a key role. In parallel, abstract mathematical constructs, such as wave aberrations and transfer functions, are also modeled for optical analysis, although they do not represent physical surfaces. Together, these modeling approaches significantly contribute to the creation of synthetic data sets. Synthetic data is increasingly gaining attention due to its ability to simulate a wide range of biometric variations without the ethical and logistical constraints of real-world data collection. Stochastic eye models are particularly valuable as they generate random biometry data reflecting the natural variability found in the general population, essential for robust optical calculations and the development of personalized medical solutions. Research on synthetic eyes, including those for healthy eyes [191] and KC-affected eyes [214], demonstrates these models’ potential to replicate realistic corneal properties and disease conditions. This facilitates the testing and optimization of diagnostic tools and treatments, leading to personalized care. Additionally, advancements in modeling the lens enable the generation of accurate synthetic data for various lens conditions [215, 216], further aiding in developing IOLs and other vision correction technologies. Such synthetic data accelerates innovation and ensures a higher standard of safety and efficacy in ophthalmic solutions.

The use of AI techniques to model the corneal surface is becoming increasingly common. However, concerns remain, particularly when studying uncommon or abnormal corneas. Selecting the best set of orthogonal functions can enhance neural network performance, providing a reliable tool for pre-screening potential KC disease. AI plays a pivotal role in enhancing the utility and accuracy of synthetic data in ophthalmology. Machine learning algorithms, in particular,excel at analyzing vast datasets to identify patterns and predict outcomes. When applied to synthetic data, AI refines generated models by learning from both real and synthetic datasets, thereby improving simulation accuracy. This synergy between synthetic data and AI-driven analysis might revolutionize ophthalmic research and technology, leading to more precise diagnostics, personalized treatments, and efficient development of new ophthalmic solutions [216].

Concluding remarks

Although the idea of surface modeling has been around for several years, the fundamental questions about sampling, orthogonality as related to the high accuracy required for clinical purposes, remain open. The main reason for this is that each surface modeled possesses specific features and therefore demand different sets of orthogonal functions which mirror some of these features, giving the researcher room for improvement.

The automatic assessment of corneas for prescreening purposes has been also around since the explosion of the use of keratometers, however it is only in the last decade that the proper tools have become massively available for researchers and practitioners to test different functions to function as ophthalmic descriptors. The idea is to find a good combination of descriptors that accurately represent the features of the various surfaces and to secure the optimal input for machine learning techniques, which also is a vastly unexplored topic.

Acknowledgements

Juan Trevino wishes to acknowledge the UPP and Tec de Monterrey for supporting the author’s work.

13. Peripheral image quality in the human eye

Charlie Börjeson and Linda Lundström

Department of Applied Physics, KTH Royal Institute of Technology, Stockholm

E-mail: cborje@kth.se and lindafr@kth.se

Status

Peripheral optics and vision are crucial for locomotion and detection, and therefore play an important role during e.g. walking, driving, and playing sports [217]. However, the human eye is optimized for central vision, both optically and neurally. The optical image quality gets progressively worse further away from the fovea, with the ganglion cell sampling density decreasing in a similar fashion. The largest aberrations in the fovea (apart from refractive errors) are spherical aberration and longitudinal chromatic aberration [218]. These remain similar in the periphery, but other optical aberrations quickly overtake the effect when going to higher off-axis angles. At first, coma and transverse chromatic aberration will appear, increasing linearly with angle. At even higher angles, oblique astigmatism, that increases approximately quadratically with angle, will start to dominate the image quality. Oblique astigmatism is a result of the apparent asymmetry of a lens when viewing it off-angle, effectively inducing astigmatism that gets worse the steeper the angle. This asymmetry creates two line foci, defining two disparate image planes (see figure 18). In an emmetropic eye, the retina coincides approximately with the sagittal image plane, where the line foci are oriented radially from the fovea. In the horizontal visual field, the resulting astigmatism therefore corresponds to a correcting negative cylinder lens with axis 90°.

Figure 18.

Figure 18.

Oblique astigmatism over the peripheral field in the human eye. The sagittal (S) image plane is shown in green and has radial line foci. The tangential (T) image plane is shown in blue and has line foci perpendicular to those of the sagittal image plane. The retina (R) often lies in-between the two image planes, closer to the sagittal plane.

Peripheral refractive errors are rarely measured or corrected, even though already the first reports in the early 1930s by Ferree and colleagues showed that both defocus and astigmatism can be very large [218]. Correcting peripheral refractive errors can be of crucial importance to people with central visual field loss, who rely solely on their peripheral vision. Additionally, they have been found to impact driving and hazard perception also in subjects with normal vision [219, 220]. However, in recent years, peripheral optical quality has gained attention in the field of myopia research due to its role in controlling eye growth. Animal studies suggest that not only central defocus, but also peripheral, affect how much the eye grows [221]. Additionally, recently introduced optical myopia control therapies that reduce myopia progression share the common factor that they affect peripheral blur, often aiming to induce relative peripheral myopia [222, 223].

Current and future challenges

Even though there is seldom need to improve the peripheral image quality in the healthy emmetropic eye, optical corrections for ametropic eyes are generally not optimized for peripheral vision. Typically, when the peripheral refractive errors in 20°–30° are larger than 1 diopter, they will affect peripheral resolution acuity in both high and low contrast [218]. It is not uncommon that optical correction by means of spectacles, contact lenses, and IOLs induce errors much larger than that [224, 225]. Some manufacturers are currently reviewing the designs of these traditional corrective lenses to address the issues with peripheral vision. This is important for activities such as locomotion, driving, and sport activities where a wide field of view is required. Errors lower than 1 diopter could also be worth correcting, as detection acuity via aliasing is very sensitive to small changes in image quality [218]. This kind of correction could be particularly useful to people with central visual field loss.

The other key question in peripheral image quality research is to understand the function and improve the efficacy of myopia control interventions. Studies have shown that relative peripheral refraction (RPR) may play a role in eye growth regulation and in the development of myopia [221]. Therefore, many of the optical interventions, developed to control myopia, aim to place the peripheral circle of least confusion in front of the retina, i.e. to create myopic RPR and halt further growth. However, RPR is not a single value, but varies over the retina and is dependent on the accommodation state and shape of the eye. For eccentricities of 20° and above, studies have shown that emmetropic eyes usually have negative RPR whereas RPR for already myopic eyes is less negative/more positive [218]. This is thought to be because of a more prolate ocular shape of the myopic eye. With accommodation, simple eye models predict RPR to become more negative because of increased field curvature [226228]. However, attempts to measure RPR with accommodation are nonconclusive. All of this makes it difficult to quantify and correlate RPR with myopia progression and optical treatment efficacy on group level.

Advances in science and technology to meet challenges

To improve peripheral visual function, it is essential to understand the relation between optical aberrations and vision. One powerful tool used for this is adaptive optics. In an adaptive optics visual simulator, a deformable mirror or a spatial light modulator is used to control what aberrations are present in part of a subject’s field of view (centrally or peripherally) [169]. This ensures that all subjects have the same retinal image quality, by eliminating the subjects’ individual aberrations. It is then possible to perform vision tests to assess how different optical aberrations affect vision and to what extent they need to be corrected. AOs can thereby be used to simulate different optical corrections, to understand how they can be improved in terms of their impact on peripheral vision. This can be valuable when developing multifocal designs for combating presbyopia, as these tend to induce additional aberrations. It is especially of use for IOLs designs, due to the difficulty of testing new designs in vivo. To make the visual experience as realistic as possible, a large field of view and possibility to allow for head and eye movements is desirable.

To understand the correlation between myopia and RPR, dedicated measurement technologies and long-term studies during ocular growth and during myopia control treatment are needed on individual level. Studies in which accommodation is not paralyzed require additional control of the accommodative state of the eye during the peripheral measurements, for example by using an additional foveal measurement path [229]. For the peripheral measurements, fast scanning devices can be used to quickly evaluate image quality over larger retinal areas [230235]. However, peripheral refraction through optical myopia control interventions poses additional challenges because of the irregular optical errors of the designs, which make the location of the circle of least confusion ill-defined. These irregular optical errors can also be difficult to pick-up with a conventional wavefront sensor (for an example, see figure 19) [236]. Hence, other peripheral refraction techniques may be needed, both objective and subjective ones.

Figure 19.

Figure 19.

Peripheral point spread function (PSF) (at 20°) for a subject wearing either no spectacles or defocus incorporated multiple segments (D.I.M.S.) spectacles for myopia control. When measured with a double-pass instrument, there is a clear widening of the PSF for the myopia control spectacles. However, this broadening is not seen with a Hartmann–Shack wavefront sensor.

Concluding remarks

Peripheral image quality is affected by large aberrations such as astigmatism, coma and transverse chromatic aberration. Understanding peripheral optical errors and their correlation with visual function is essential for improved vision for people in all age groups. The two major applications for research on peripheral image quality today are improving optical corrections for peripheral visual tasks and developing efficient optical myopia control interventions.

Peripheral acuity gets worse with increased peripheral optical errors, which are often amplified by conventional spectacles, contact lenses and IOLs. This can affect important visual functions necessary for safe locomotion, and is of special concern for people with central visual field loss. AOs visual simulators can be used to assess new optical designs and to understand how aberrations affect vision.

Myopia progression is affected by peripheral image quality, but the exact mechanisms are not fully understood. Moreover, optical myopia control therapies’ effect on peripheral image quality is difficult to measure with conventional instruments. Multi-path and/or scanning devices with control of accommodation are needed to develop more efficient and personalized therapies.

Acknowledgements

The authors currently have funding for research within myopia by the Swedish Research Council (Nos. 2019-05354 and 2023-05428) and within vision for elderly by the European Union through the MSCA Doctoral Network ACTIVA (101119695).

14. Optical aberrations of the human eye

Seung Pil Bang1 and Geunyoung Yoon2

1Department of Ophthalmology, Keimyung University Dongsan Medical Center, Daegu, Republic of Korea

2College of Optometry, University of Houston, Houston, TX, United States of America

E-mail: gibong87@dsmc.or.kr and gyoon2@central.uh.edu

Status

Over the past several decades, the study of monochromatic aberrations in the human eye has been a focal point in physiological optics. Early methods such as the Scheiner double pinhole [237], the Foucault knife edge [238], and the crossed-cylinder aberroscope [239] were attempted, but found to be labor-intensive and difficult to analyze. In the 1980s, the rise of corneal refractive surgery led to increased patient complaints about glare and visual discomfort, sparking significant interest in measuring ocular aberrations within ophthalmology and vision science. This demand for precise quantification of the ocular aberrations prompted the development of the highly effective Shack–Hartmann sensor [240, 241], which represented a notable technological breakthrough. Subsequent advancements introduced various techniques, including the ray-tracing aberrometer [242], the Tscherning aberrometer [243], the dynamic skiascope [244], and the pyramidal sensor [245] (table 1). These sensors primarily serve three purposes: (1) rapid and objective quantification of ocular aberrations, (2) understanding the impact of the aberrations on visual performance, and (3) facilitating vision correction through adaptive optics [154], lasers [246] and ophthalmic lenses [247]. Technological advances have expanded their clinical applications to other areas including tear film and dry eye [248], characterization of ocular conditions like KC [249] and cataracts [250], presbyopia correction [251], and myopia control [252].

Table 1.

The current wavefront measurement technologies.

Technology Principle Pros Cons
Shack–Hartmann wavefront sensor Measures local wavefront slopes at once using an array of microlenses
  • -

    Widely used and validated

  • -

    High temporal and spatial resolution

  • -

    Good for real-time measurement

  • -

    Tradeoffs between dynamic range and measurement sensitivity

  • -

    Requires higher input power

  • -

    Aliasing if under-sampled


Ray-tracing Aberrometer Sequentially measures local wavefront slopes
  • -

    High dynamic range

  • -

    Good for irregular corneas

  • -

    Sequential (slow acquisition)

  • -

    Requires stable fixation

  • -

    Complex calibration


Tscherning aberrometer Projects a laser grid onto the retina and captures distortion
  • -

    Same as Shack–Hartmann wavefront sensor

  • -

    Lower spatial resolution

  • -

    Limited dynamic range

  • -

    High-sensitivity camera required


Dynamic skiascope Measures wavefront error based on moving light and analyzing reflex
  • -

    Can capture accommodative changes

  • -

    Suitable for natural viewing conditions

  • -

    Moderate accuracy

  • -

    Affected by eye movement

  • -

    Relatively slower


Pyramidal sensor Uses a pyramid prism to split the incoming light into four different spots on a CCD surface. Their differences provide information about wavefront gradients
  • -

    Very high sensitivity

  • -

    Excellent for small residual aberrations

  • -

    Complex setup

  • -

    Sensitive to alignment and vibration

  • -

    Limited dynamic range

Current and future challenges

Current ocular wavefront sensing technology presents several technical challenges. One primary limitation is the spatial resolution imposed by the discrete sampling of the wavefront. For example, the size of lenslets in a Shack–Hartmann sensor can lead to spatial under-sampling [253], causing variations within each lenslet to be averaged and lost. Additionally, intraocular scatter induced by cataracts or scars can degrade spot quality, increasing errors in estimating the wavefront slope. Ocular aberrations also vary over time due to factors such as fluctuations in the tear film’s thickness and refractive index, accommodation, and fixational eye movements [248]. The speed at which these changes can be traced is limited by the sensitivity of the CCD and CMOS sensors at the wavelength of light used. The very low light levels (0.01%–0.001% of input power) from the eye further complicate this challenge. Trade-offs exist between spatial and temporal resolution in ophthalmic applications. Additionally, it is challenging to quantify peripheral aberrations, which provide important clues about how peripheral optics influence emmetropization and refractive error development [230, 233]. A few scanning wavefront sensors have been proposed, but improvements in compactness and portability are needed. Another challenge lies in wavefront reconstruction methods. Another challenge lies in wavefront reconstruction methods. While modal wavefront reconstruction (using Zernike polynomials) is common in commercial sensors and decomposes different types of aberrations, it acts as a low-pass spatial filter, removing potentially important high spatial frequency wavefront information. The zonal reconstruction algorithm [254] can overcome this challenge and needs to be refined and implemented in addition to the modal algorithm.

Although a complete assessment of the optical imperfections of the eye provides insights into the image quality formed on the retina, the complex post-receptoral and neural processing contributing to subjective perception is of significant scientific interest. One intriguing finding is that the neural system can reduce perceived optical blur through long-term adaptation to the individual eye’s habitual optical profile [130, 255]. Further study is needed to identify the mechanisms by which visual experience with specific ocular optics alters our perception. This research will also improve our ability to predict subjective refractive errors from measured aberrations [256]. Selecting the reference axis along which the eye’s aberrations are measured can significantly impact the outcomes of advanced vision corrections with lasers and ophthalmic lenses [257]. Clinical accessibility to wavefront sensors is a significant challenge due to the lack of low-cost, stand-alone aberrometers available commercially. This limitation hinders clinicians’ ability to diagnose patients’ visual problems and enhance corrective outcomes.

Advances in science and technology to meet challenges

Advances in sensor technologies [258] have enabled increased spatial resolution of Shack–Hartmann wavefront sensors by magnifying the eye’s pupil onto the lenslet array plane with a 4-f telescope system [253]. This effectively reduces the sampling steps on the eye’s pupil by the magnification factor. Other phase imaging techniques, such as quadriwave lateral shearing interferometry [259] and phase diversity/retrieval [260], also offer the potential for achieving higher sampling resolution (table 2). These technologies will eventually allow for the direct quantification of intraocular scatter. However, due to the relatively low quantum efficiency (QE) of silicon-based sensors at near-IR wavelengths, the methods mentioned above require higher power of the input laser closer to the maximum permissible exposure (MPE), raising eye safety concerns. To overcome this issue, using an indium gallium arsenide (InGaAs) sensor, which has excellent QE (>80%) in the short-wave infrared band (>900 nm), is a viable solution. This newly available sensor offers benefits including higher MPE at longer wavelengths and a substantially faster frame rate, making it possible to measure dynamic ocular aberrations at significantly higher speeds [261]. Moreover, the ability to use a longer wavelength of light that is completely invisible to the eye opens new possibilities for testing visual functions across a wide range of the visual field without visual disturbances from the light source.

Table 2.

The emerging wavefront measurement technologies.

Technology Principle Pros Cons
High-resolution Shack–Hartmann (pupil magnification, or custom sensors) Enhanced Shack–Hartmann design with pupil magnification or more sensitive sensors
  • -

    Better sensitivity to small optical defects

  • -

    Suitable for complex IOL and corneal surface modeling

  • -

    Better temporal resolution

  • -

    Eye safety

  • -

    Reduced dynamic range

  • -

    More sensitive to noise and alignment

  • -

    Increased data and computational demands


Quadriwave lateral shearing interferometry Uses a 2D diffraction grating (modified Hartmann mask) to create 4 sheared replicas of the wavefront; computes gradients in two axes
  • -

    High sensitivity and spatial/temporal resolution

  • -

    Compact and robust

  • -

    Achromaticity

  • -

    Phase unwrapping needed

  • -

    Sensitive to system aberrations


Phase retrieval (Image-based) Reconstructs wavefront phase from a sequence of intensity images at different focus levels
  • -

    No physical wavefront sensor needed

  • -

    Works in scattering or defocused conditions

  • -

    Integrates well with OCT/fundus imaging

  • -

    Computationally intensive

  • -

    Needs high-quality images and accurate system model

  • -

    Phase ambiguity issues

Optical tools such as adaptive optics and free-form ophthalmic lenses based on ocular wavefront sensing are key to understanding the interaction between the eye’s optics and visual perception. These tools allow researchers to bypass optical imperfections, enabling the evaluation of neural functions and the induction of specific optical profiles for comparison of neural processing across different individuals. Along with advancements in these techniques, developing innovative visual psychophysical paradigms and optical imaging modalities is critical for revealing mechanisms related to various aspects of human vision. Ongoing progress includes creating more sophisticated visual quality metrics that represent real-world visual tasks, incorporating factors such as spatial frequency, contrast, color distribution in natural scenes, retinal sampling frequency, motion, and binocularity.

Concluding remarks

Ocular wavefront sensing technology has revolutionized our understanding of the eye’s optical imperfections and how to correct them to improve visual performance. Scientific and clinical research findings are now more objective and precise, offering valuable insights into how human vision works in relation to the eye’s optical characteristics. Addressing these challenges will enhance our ability to characterize the eye’s optics both spatially and temporally, under various ocular conditions. Successfully translating these advancements into practical vision correction will enable individuals to achieve optimal visual quality customized to their needs, significantly improving their quality of life.

Acknowledgements

Supported by United States National Eye Institute (Grant Number: R01 EY014999 and R01 EY034151) and the National Research Foundation of Korea (NRF) Grant funded by the Korean government (MSIT) (IRIS RS-2024-00457444).

15. IOP of the human eye

Karol Karnowski1,2, Bartlomiej J Kaluzny3 and Ireneusz Grulkowski4

1International Centre for Translational Eye Research, ul. Skierniewicka 10A, 01-230 Warsaw, Poland

2Institute of Physical Chemistry, Polish Academy of Sciences, ul. M. Kasprzaka 44/52, 01-224 Warszawa, Poland

3Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, ul. M. Curie Skłodowskiej 9, 85-094 Bydgoszcz, Poland

4Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, ul. Grudziadzka 5, 87-100 Toruń, Poland

E-mail: kkarnowski@ichf.edu.pl, b.kaluzny@cm.umk.pl and igrulkowski@fizyka.umk.pl

Status

The IOP stands as a fundamental parameter that maintains the shape of the eyeglobe and enables the physiological functions of ocular tissues. Typically ranging from 10 to 21 mmHg, normal IOP is essential for preserving the eye’s optical properties. The precise regulation of IOP is determined by the interplay between the production and outflow of aqueous humor within the posterior and anterior chambers. Elevated IOP is a primary risk factor for glaucoma, a group of optic neuropathies being a leading cause of irreversible blindness worldwide. Beyond glaucoma, IOP may reflect pathophysiological changes that indicate the onset of conditions such as uveitis, pigment dispersion syndrome, or angle-closure crisis.

IOP not only directly influences ocular blood flow but also impacts the optical system of the eye. By preserving the globe’s shape and the curvature of the cornea and sclera, IOP helps sustain the eye’s refractive architecture—particularly the anterior segment. Transient IOP changes arise from blinks, saccades, and ocular pulse amplitude. Diurnal IOP fluctuations can induce changes in corneal curvature, thickness, which impact ocular wavefront aberrations [262]. Healthy eyes, however, tolerate the ocular pulse and IOP variations without noticeable changes in quality of vision, which is explained by self-adjustment mechanism of the cornea-sclera-limbus system that prevents degradation of retinal image [263]. Elevated IOP is associated with thicker corneas (in ocular hypertension), minimal corneal curvature change, slight globe expansion and axial elongation (especially in infants), and significant optical nerve head remodeling (cupping and lamina deformation) [264, 265]. Those effects can induce higher-order aberrations, shifting the retinal image plane and compromising retinal image quality. On the other end, if IOP drops too low (ocular hypotony), the eye loses its normal pressure support. The cornea may become irregular or buckled (leading to astigmatism), and reduced volume can cause retina folds, collectively degrading the retinal image. Clinically, severe hypotony is known to cause a hyperopic shift from a shortened eye length [266]. IOP-related alterations in ocular shape and biomechanics are increasingly recognized as relevant in myopia progression, refractive surgery outcomes, and ocular diseases involving structural remodeling.

The measurement and interpretation of IOP extend beyond mere numbers. Historically, the need to measure IOP accurately has driven innovations, leading to a variety of techniques as shown in figure 20 [267, 268]. Goldmann applanation tonometry has long been regarded as the gold standard. Non-contact methods, like the air-puff tonometer (e.g. ORA, Corneal Visualization Scheimpflug Technology CST), offer a touch-free alternative. Dynamic contour tonometry (DCT), represented by the Pascal tonometer, seeks to overcome corneal influence by matching the device’s contour to that of the cornea, aiming for IOP readings less affected by corneal properties. Handheld devices (Tono-Pen or iCare tonometers), bring flexibility to the clinical setting, allowing measurements in various patient positions and circumstances. These devices are particularly useful for pediatric patients.

Figure 20.

Figure 20.

Recent and emerging IOP measurement and monitoring methods. On the right, a cross-sectional view of the human eye displays the aqueous humor circulation pathways indicated by red arrows. Intraocular pressure (IOP) affects all structures of the eye. (A) Mechanical stimulus methods (e.g. Goldmann tonometer, iCare, or DCT). (B) Non-contact methods based on air puff stimuli. (C) Wearable or implantable pressure sensors enabling remote IOP monitoring. (D) IOP estimation based on statistical analyses of corneal cross-section images. (E) IOP values extracted pupillary reaction to light stimulus.

Current and future challenges

Clinically available techniques for estimating IOP are based on indirect measurements, generating difficulties in the proper interpretation of the results. Those fundamental challenges in IOP estimation stem from the inherent biomechanical complexity of the eye, which introduces variability in the IOP results. Differences in corneal geometry (thickness, curvature), hydration, corneal biomechanics (rigidity), and cardiac cycle have been identified as factors leading to inaccuracies in IOP readouts [269]. Thicker corneas often result in IOP overestimation, while thinner corneas may yield lower IOP results, potentially masking pathological changes that also degrade optical quality.

Diurnal fluctuations in IOP and short-term IOP variability also need to be taken into account during the assessment of glaucoma risk. Existing models often assume static IOP, but real-life dynamics (e.g. posture, circadian rhythm, Valsalva maneuvers) can alter pressure significantly. Continuous 24 h IOP monitoring is still in its infancy, which prevents gaining insight on how these dynamics influence ocular perfusion, biomechanics and visual outcomes. Moreover, combining IOP with ocular biomechanics, blood flow, and visual function data (through multimodal devices) promise to develop comprehensive models of ocular homeostasis under variable pressure and mechanical stress. This could lead to identification of true risk of glaucoma and optic nerve damage and a more personalized strategy of glaucoma management.

Additionally, the IOP assessment is impacted by the limitations of existing tonometry technologies. Contact nature of measurements or the use of anesthetics generates discomfort, increases infection risks patient anxiety, particularly among children and the elderly. Several studies demonstrated another complexity, namely the lack of consistency between different tonometry devices, which often provide different IOP measurements [270]. Therefore, results’ standardization across clinics or in longitudinal studies is challenging. An ideal tonometer should offer not only high accuracy and patient comfort, but also account for individual corneal thickness, curvature, and biomechanical differences that influence both IOP and optical parameters. It should be capable of reproducible measurements across diverse patients while minimizing/eliminating physical contact with the eye or using stimuli better tolerated by patients. Technological innovation must also address the need for portability, automation, and compatibility with digital platforms, allowing less specialized personnel to perform the measurements objectively.

Future challenges go beyond technical refinements—they involve rethinking how IOP measurement integrates with precise eye modeling. New biomechanical and fluid dynamic models of the eye will not only determine of IOP-related stress or predict tissue deformation but will also simulate visual consequences via coupling with computational optics. These biomechanical-optical interdependencies are especially relevant in patients undergoing refractive surgery, where both IOP and corneal optics must be precisely managed.

Advances in science and technology to meet challenges

The challenges listed above underscore the need for continued innovation and refinement in IOP evaluation methods. In response, we observe upgrading existing devices and developing novel solutions for IOP assessment.

Non-contact tonometry, through more advanced analysis of air-induced corneal deformation, improves understanding of IOP and corneal biomechanics relation. New software versions account for factors skewing IOP measurements, which enhances the diagnostic capability (e.g. Goldmann-correlated IOP and corneal-compensated IOP in ORA, and bIOP in CST). Older tonometry concepts are also being realized in low-cost systems on widely available smartphones [271]. Air-puff stimulation is combined with modalities like OCT, enabling high-resolution imaging and more precise identification of corneal surfaces [272]. Recent OCT advances on imaging capabilities (e.g. cross OCT B-scan, optical biometry) provide more comprehensive analysis of ocular tissue response to stimuli [273, 274]. Modern diagnostic devices (e.g.Visionix VX) combine non-contact tonometry with aberrometry, keratometry, corneal topography and Scheimpflug imaging, providing a more comprehensive assessment for efficient glaucoma screening [275]. The development of rebound tonometers addresses the challenges of IOP measurement, enabling wider use of these devices. Improved versions of iCare provide fast and more precise IOP measurement for patients in a supine or upright position. Recently introduced iCare HOME generation, is the first hand-held self-tonometry for home measurements during daily activities [276, 277].

Perhaps most intriguing innovations include implantable pressure sensors and smart contact lenses. Those emerging solutions are capable of capturing IOP fluctuations throughout the day that single measurements might miss. Smart contact lenses or IOLs implants embedded with micro-sensors provide a non-invasive means for IOP monitoring and cost-effective smartphone-based detection [278, 279]. The wearable and implantable technology and self-tonometry promises to transform patient care [280, 281].

Innovative drug delivery systems are also leveraging IOP as a trigger for therapeutic action. Devices that release medication in response to elevated IOP could provide targeted treatment for glaucoma patients, ensuring timely intervention when it is most needed [281, 282]. In addition, surgical innovations adapt in response to pressure changes or leverage IOP to improve their function. Modern cataract surgery systems use smart fluidics to maintain stable IOP throughout procedures thanks to the built-in pressure sensor that detects fluctuations in real time, allowing the system to compensate IOP spikes or drops almost instantly [283].

Furthermore, understanding how IOP influences ocular biomechanics contributes to broader insights into eye health. In recent years, significant progress has been made in developing optical models of the human eye that incorporate biomechanical properties and account for the effects of IOP. These integrative models are designed not only to understand the mechanical behavior of ocular tissues under physiological and pathological conditions but also to predict how such changes may affect visual performance—bridging a critical gap between biomechanics and optics [263, 284]. Furthermore, investigations into myopia progression, for instance, consider the role of IOP in scleral remodeling [285]. By examining these correlations, scientists hope to uncover new strategies for managing refractive errors.

Finally, integrating of AI and machine learning tools offers another avenue for innovation. By recognizing patterns and predicting disease progression, these tools could enhance early detection of glaucoma and optimize therapeutic interventions [286].

Concluding remarks

IOP remains a cornerstone of ophthalmic practice, its measurement and management are essential for preserving vision and preventing blindness. While traditional techniques have provided a foundation for care, the challenges they present highlight the need for continued innovation. Emerging technologies offer exciting possibilities for more accurate, continuous, and patient-friendly IOP monitoring, exploring potential to stabilize or predict changes in optical performance of the eye and paving the way for personalized medicine and improved outcomes. Continued investigation into the IOP-optics relationship is crucial for refining both clinical management and theoretical models of ocular optics.

Global health initiatives recognize the importance of accessible eye care. Developing affordable, user-friendly tonometers for use in under-resourced areas could make a significant impact on the global burden of glaucoma-related blindness. Telemedicine platforms, enhanced by smartphone-based technologies, may extend the reach of ophthalmic services, bringing essential care to remote communities.

Acknowledgements

The authors gratefully acknowledge support from the National Science Center (IG; 2021/43/I/NZ5/03328), and from International Research Agendas programme of the Foundation for Polish Science co-financed by the European Union under the European Regional Development Fund (KK; MAB/2019/12).

16. Varying optical power design of progressive spectacles, contact, and IOLs

Sergio Barbero

Instituto de Óptica (CSIC), Serrano 121, Madrid, Spain

E-mail: sergio.barbero@csic.es

Status

The degradation of the accommodation capabilities of the crystalline lens with age, i.e. presbyopia, causes blurred images when viewing objects at different distance locations. When presbyopia combines with far-vision ametropia, an optical element providing varying optical power, either through continuous extended-depth-of-focus (EDOF) or discontinuous multifocal (MF) variation, is required. Bifocals spectacles, already known in Benjamin Franklin’s times (late 18th century), one of his inventors, were the first optical elements providing multifocality. However, it was not only until the twentieth century when with the advent of, on the one hand, contact, and IOLs, and, on the other, progressive addition lenses, that optical technology offered multifocal solutions covering not only far and near vision but also intermediate distances. Moreover, in recent times, multifocal solutions are also being used for other visual functionalities, such as myopia control [287]. In ophthalmic lenses, these designs resort to geometric, diffractive, or a combination of both effects. The goal consists of distributing light intensity along different foci (MF) or an extended region (EDOF). A surface with non-constant mean curvature is required when a refractive element is employed. Here, we focus on the optical design challenges set by EDOF and MF solutions; hence, our analysis excludes procedures based on reshaping human eye tissues, such as corneal reshaping through orthokeratology, or the ambitious goal of restoring accommodation. Another way to classify varying optical power solutions for vision is by considering the underlying interaction between the visual system and the optical element. Basically, there are two options. In one case, when the eye looks at a fixed distance, the optical element, either an IOLs or CLs, provides, on the retina, an in-focus image with superimposed blurred images formed by other object planes. Afterwards, the neural system is supposed to be able to select the focused image for each visual target, filtering the blurred signals from the other foci that are perceived as ghost images or halos. This is called the simultaneous vision principle, illustrated in figure 21.

Figure 21.

Figure 21.

Scheme showing how the simultaneous vision principle works illustrated with a contact lens. A bundle of infinitesimal rays coming from a far Snell chart (green solid line) passing through the central part of a multifocal contact lens converge onto the retina; however, another bundle of rays (green dashed line) that passes through the external part of the contact lenses is out-of-focus at the retina. Conversely, rays from a near object and passing from the peripheral part of the contact lens (red solid line) converge onto the retina, but not the ones passing through the central part.

The second case, employed in progressive addition lenses (PALs, for short), is sometimes called the alternating principle. A surface, or more rarely the combination of two, is designed to contain a spatially varying mean curvature. The eye scans, sequentially on time, each viewing area of the PAL searching for the required optical power. There are two clear zones: far-distance vision (center of the lens) and near-view (low nasal portion) and in between these two zones, the power varies progressively. See figure 22.

Figure 22.

Figure 22.

Scheme showing how the alternating vision principle works. The eye changes its gaze direction scanning the different parts of the PAL surface searching for the required optical power. The figure illustrates when looking at the book (near distance: 3 D), a bundle of infinitesimal rays going through the lower part of the PAL converge at the retina. The upper figure shows mean curvature and cylinder distribution maps of a realistic PAL.

Nevertheless, the classification above admits some exceptions; for instance, some rigid contact lenses are designed to permit slight centering variations with the viewing distance, thus working under the alternating principle [287].

Current and future challenges

The greatest challenge in PAL design is to find a smooth progressive mean curvature surface (providing the prescribed optical power) but with a controlled amount of induced astigmatism. Differential geometry theorems make the presence of astigmatism unavoidable [288] because, within a smooth Euclidean surface, zero astigmatism is only possible at isolated points or lines. Minkwitz’s theorem establishes that along an umbilical (zero astigmatism) line of a smooth surface with a rate of change of mean curvature given by kr, the cylinder along the orthogonal direction to that line increases twice as quickly as. Recently, it has been derived a generalization of Minkwitz’s theorem that provides the exact magnitude of the cylinder at any arbitrary point as a function of the geodesic curvature and the ratio of change of a principal curvature along a principal line [288]. Although designing PALs admits several approaches, the key to the majority is to define a cost function that includes different weighted targets, which is subsequently minimized [289]. Typically, the cost function prescribes mean power and cylinder. Moreover, current designs consider that both mean power and cylinder depend, not only on the progressive surface differential properties but also on the angle of incident of the ray onto the surface, i.e. the gaze direction [289]. Besides mean power and cylinder, other targets to the cost function may be considered, for instance, power and cylinder variation, distortion, or even higher-order aberrations [289]. Concerning IOLs and CLs, there are several types of designs: multifocal, designed to provide two or more focuses with separated optical zones, bifocal (multifocality restricted to two focuses), and varifocal power (EDOF), where the refractive power varies progressively with more or fewer smoothness levels. For a long time, these lenses have been restricted to be rotationally symmetric; either concentric designs (segmented discrete rings of alternating power) or aspheric designs (described by a conic plus some extra aspherical coefficients). However, in recent times, the improvement in the manufacturing capabilities of free-form lenses and phase masks, and the progress in their theoretical design, have made possible non-rotationally symmetric designs; starting with the work of Kołodziejczyk et al [290]. These exhibit two major advantages concerning the former. First, major robustness to pupil changes, since the varying size of the pupil due to light intensity variation, accommodation, or aging limits the amount of light reaching the retina, thus affecting the visual contrast and the multifocality performance. Second, the capacity to provide a higher light concentration in the desired regions [291]. Besides pupil size, correct lens centering and the interaction between the optical element and subjects’ aberrations are critical factors; particularly, in soft contact lenses, where decentering is normally induced in the inferior and temporal direction due to gravity and eyelids. Some designs have explicitly considered the eye-lens aberrations coupling, either using a generic pseudophakic eye model [292] or some personalized anatomic data [293].

An essential issue in simultaneous vision solutions is to select the mathematical metric, required in the design process, that better matches the visual experience. Typically, the depth-of-focus or multifocality of the eye is estimated from objective optical computations using various retinal image quality metrics [294]. These combine the purely optical effects of the optical system with an estimate of the subsequent neural process. The boom in experimental visual simulators, with the emergence of techniques allowing spatial control over the phase of light beams, allows direct analysis of which designs offer a better visual experience. A subsequent design procedure requires obtaining the geometry of the lens from the optimal wavefront at the pupil plane [295].

Advances in science and technology to meet challenges

Ophthalmic lenses are almost universally made of bulk lenses that change light through refraction and/or diffraction. However, the spring up of flat optical-element technologies, using metamaterials and metasurfaces, offers exciting potentials in multifocality applications for vision thanks to, on the one hand, their thin and lightweight structures and, on the other hand, their ability of high-precision phase manipulation employing nanostructures at a subwavelength scale. Two design principles applied are the magnetic dipoles and the Pancharatnam–Berry phase, or geometric phase (GP), which generates a varying phase through a closed path [296]. The number of foci and the amount of energy light distribution can be controlled by setting the structure, number, and thickness of stacked GP layers. Some MIOL designs already employ a geometric GP structure. Particularly, Na et al [297] and Lee et al [298] proposed combining the GP structure with a thick refractive lens. Nevertheless, the scaling up to mass production of ophthalmic lenses including metamaterials still poses some significant hurdles because of the requirement of high-precision fabrication techniques, such as electron beams or nanoimprint lithography [299]. Another potential disruptive technology, which, although ultimately oriented to accommodation restoration, could also be used in multifocality or even as a hybrid technology, is the integration of electrically tunable liquid crystal lenses (TLCLs). These devices explore the capacity to modify the refractive index of liquid crystals by applying variable electric fields. However, the great challenge in TLCLs for ophthalmic solutions is to detect the object locations for different viewing distances and send that information to the TLCL. Some examples of the application of this technology are: IOLs [300], CLs [301], and spectacles [302]. In PAL design, one of our research interests lies in finding the most convenient cost function, which in recent times has been accepted to be, to some degree, patient-dependent. Therefore, a lot of effort is being put into feeding the personalized designs with individual user parameters such as the patient’s relationship between head and eye movements (gaze dynamics), the daily activities of the wearer, the influence of distortion on perception [303], or the binocularity function. Theoretically, once the cost function is properly configured, it would be highly convenient to prove the existence and uniqueness of its solution. This goal has been pursued by [304] considering the classical functional that only combines mean power and cylinder as targets. Here, it is worth noticing the connection between this function and Willmore’s; a very active field of research in mathematics [305]. Moreover, this connection may also be used for designing astigmatism-free transition zones in segmented multifocal designs [305]. Finally, PAL designs would benefit from any advances in the progress of numerical algorithms that improve the ability to reach optimal solutions [306].

Concluding remarks

Due to the overall aging of the world’s general population, the social impact of presbyopia correction is becoming increasingly important. Both theoretical and technological challenges make the technologies of multifocality and extended-depth-of-focus a very active field in visual optics. Moreover, some disruptive new technologies that have emerged in recent times, such as free-form high-performance manufacturing or meta lenses, to name a few, exhibit exciting potential for the near future.

Acknowledgements

This work was supported by Grant PID2020-113596GB-I00 from the Spanish Ministerio de Ciencia e Innovacion.

17. IOLs and peripheral vision

Pablo Artal and Juan Tabernero

Laboratorio de Optica, Universidad de Murcia, 30100 Murcia, Spain

E-mail: pablo@um.es and juant@um.es

Status

In a natural phakic eye, the crystalline lens is a thick lens with a GRIN that supports high-quality imaging over a broad visual field [307]. Traditional IOLs, however, are primarily designed to optimize central or foveal vision, often neglecting the quality of vision in the peripheral retina. Most IOLs feature a thin, biconvex design to facilitate easier implantation, but this simplicity comes at a cost: a degraded image quality in the peripheral retina compared to that provided by the natural crystalline lens.

While the limitations of IOLs in peripheral vision have been known for some time [308], they have received little clinical attention, based on the assumption that peripheral optical degradation would remain within the retinal and neural tolerance limits. This would imply a limited impact in peripheral and functional vision. However, recent research challenges this view. Jaeken et al [225] demonstrated that patients implanted with biconvex IOLs experienced significantly more astigmatism and defocus in their peripheral vision compared to the natural lens in their fellow eye. Furthermore, Togka et al [309] found that this optical deterioration reduces contrast sensitivity in the peripheral visual field, affecting the patient’s ability to detect objects and changes in contrast outside the central vision area.

Reduced peripheral visual quality after cataract surgery can have considerable implications for a patient’s quality of life [310]. Peripheral vision is essential for many daily tasks, including navigation, recognizing objects in the surrounding environment, tracking multiple objects simultaneously, and planning eye movements. Degraded peripheral optics can impact fundamental activities like navigating stairs [311] and driving [220], where awareness of one’s surroundings is crucial. Moreover, compromised peripheral vision is associated with an increased risk of falls, underscoring its importance in maintaining spatial orientation and overall safety.

These findings highlight the need for innovations in IOL design that accounts for peripheral as well as central vision. Some recent developments have focused on addressing these issues by modifying the design of IOLs to improve peripheral image quality, such as incorporating non-biconvex shapes or adjusting the refractive index profile. By better mimicking the natural crystalline lens, these advanced IOLs could help restore a more natural, seamless visual experience after cataract surgery. Improving peripheral optics in IOLs not only enhances central and peripheral vision balance but also holds potential for significantly improving patients’ functional abilities and quality of life.

Current and future challenges

These findings of suboptimal peripheral optics and their visual consequences in pseudophakic patients prompted the development of an alternative IOLs designed to preserve high-quality peripheral optics through an inverted meniscus design [312]. These lenses are intended to emulate the peripheral optical performance of the natural crystalline lens. In this design, the posterior surface curvature radius is smaller than the anterior surface curvature, with this ratio varying according to the IOL’s power. A large range of powers of the lenses (10–30D) can be obtained with a proper selection of radii. Figure 23 illustrates an example of this lens type (ArtIOL, Voptica SL, Murcia, Spain).

Figure 23.

Figure 23.

Anterior OCT image of a patient implanted with an inverted meniscus IOL.

Advances in science and technology to meet challenges

The inverted meniscus lenses have already been implanted in a significant number of patients, demonstrating notable improvements in both image quality and peripheral contrast sensitivity. Figure 24 illustrates the average peripheral refraction across a cohort of patients with standard biconvex lenses compared to those with inverted meniscus lenses [313]. In these patients the impact of a better optics was a better contrast sensitivity in the periphery.

Figure 24.

Figure 24.

Peripheral refraction in two groups of patients implanted with standard biconvex IOLs (black symbols) and an anterior meniscus IOL (blue symbols). Reproduced with permission from [313]. © The Authors, CC BY-NC 4.0.

On the other hand, standard biconvex IOLs tend to introduce eccentricity-dependent shifts in the visual field, a distortion that appears to be minimized with inverted meniscus IOLs. We compared pre- and post-operative fundus images from cataract patients to assess shifts in retinal landmark positions induced by IOL implantation at different eccentricities. Results indicated that these displacements were considerably less pronounced with inverted meniscus IOLs than with traditional biconvex lenses.

This finding suggests that standard IOLs may disrupt the world-to-retina mapping, potentially leading to distortions in the perceived positions of peripheral objects. Such visual inaccuracies could increase the likelihood of spatial errors, potentially resulting in misjudgments or accidents, particularly in complex visual environments. However, it is possible that neural adaptation processes could gradually restore the normal perception of the visual field, correcting for these distortions over time. Further studies are needed to fully understand the extent of this adaptation and its implications for patient safety and quality of life.

Concluding remarks

Peripheral optics and vision in the pseudophakic eye have been largely ignored. However, the potential impact in the quality of vision is quite significant. New designs of IOLs optimizing peripheral optics are already underway. Alternative design options and new testing strategies should be developed in the future to incorporate these ideas into the mainstream cataract practice.

18. Advances in contact lens optics

Pete Kollbaum

Indiana University, 800 East Atwater Avenue, Bloomington, IN 47405, United States of America

E-mail: kollbaum@iu.edu

Status

Although the exact time is not precisely known, the earliest form of contact lenses were described by the early 1500s. These (dangerous) glass lenses remained largely unchanged until the mid 1900s when polymethylmethacrylate plastic lenses were first introduced. Like the earlier lenses, however, these lenses remained comfortable and safely wearable for only short periods of time as they prevented the necessary oxygen from reaching the cornea. Fortunately, only a few years later ‘soft’ hydrophilic (polymacon) lenses were developed. These original lenses aimed to correct the refractive error of the eye. They did this in the simplest form by changing the optical path length of the eye plus lens. Historically, these lenses corrected spherical and regular/irregular (e.g. astigmatic) refractive errors, but as society has progressed there has been significant interest in these lenses accomplishing other and more sophisticated goals. Specifically, the goals of contact lenses have expanded optically so the lenses aid eyes and correct vision better and in different ways, but the goals of lenses have also grown beyond merely those related to correcting vision. This paper briefly discusses a few optical or optically related advancements of contact lens corrections, as well as associated technological advancements necessary to achieve these advancements. Discussion of non-optical advancements, such as those related to lens materials (e.g. drug eluting) or non-optical features can be found elsewhere.

Current and future challenges

On average, human eyes contain approximately +0.15 μms (6 mm pupil) of primary spherical aberration [314]. All spherical lenses also contain inherent levels of spherical aberration which vary as a function of lens power. To counteract these two issues, contact lenses with aspheric surfaces are commonly employed [315]. Although some lenses have been manufactured aiming to introduce no spherical aberration regardless of lens power, none are currently commercially available. Many lenses are made with spherical aberration control to introduce an amount of spherical aberration approximately equal in magnitude but opposite in sign to that of the average eye (during relaxed accommodation) to reduce the total overall aberration when on the eye. These aspheric lens surfaces now form the basis for many types of lenses beyond those which correct myopia and hyperopia.

To correct non-rotationally symmetric optical errors, such as astigmatism, lenses must be stabilized. Stabilization methods include prism ballast, peri-ballast or modified prism ballast, and dual thin zone. These mechanisms may also induce asymmetric aberrations, however. Non-rotationally symmetric, stabilized lens designs also initially formed the basis of lenses aimed to counteract for the age-related loss of the eye’s accommodative ability which happens during presbyopia. Currently, however, rotationally symmetric designs are the most common, and often occur through the introduction of either primary/secondary spherical aberration [316] or through annular segments of different refractive powers [317]. Diffractive designs are also possible, but not currently commercially available in contact lens designs. The newest classification of multifocal lenses have become broadly termed ‘extended depth of focus’ contact lenses. This somewhat ambiguous term could theoretically apply to many lens designs, but generally contains lenses which have non-monotonic, non-aspheric, and/or aperiodic profiles. These lenses often contain multiple higher order spherical aberrations, conical surfaces (e.g. axicons) [318], or unique asymmetric angular elements [319, 320].

Multifocal contact lens designs have also been recently used to slow myopia progression in children, based on the theory that myopia progression is due to peripheral hyperopic focus. Specifically, contact lenses which aim to control myopia progression, therefore, aim to induce peripheral myopic defocus [321]. Most designs explored or currently utilized to control axial eye growth are somewhat similar to the rotationally symmetric contact lenses for presbyopia, such as those containing annular rings of multiple optical powers.

Advances in science and technology to meet challenges

All contact lenses typically decenter when on the eye relative to the pupil center [322]. Any on-eye decentration of a lens which contains aberration, such as a multifocal or myopia control design, however, will introduce other aberration in direct proportion to the amount of lens aberration and decentration [323]. To compensate for this issue, stabilized lenses with decentered optical zones (to align with the pupil center) have been explored [324].

An additional consideration of multifocal lenses, such as those used to correct presbyopia or slow eye growth is that lenses with multiple optical powers simultaneously create multiple images seen by the wearer. The top row of figure 25 shows the optical power of three sample theoretical lens designs for an 8 mm pupil; a multi-ring, dual-focus myopia control (left column), a lens with a center focused for near viewing optics (green and yellow) and surround for distant viewing optics (blue)(middle column), and a lens with a center focused for distance viewing optics (blue) and surround for near (green) (right column). The middle row of this figure shows the geometrical optics PSF created by these lenses as if viewing a distant source. The bottom row depicts the simulated retinal image quality through these lenses of a 20/120 and 20/40 size letter. In each of these designs which contain multiple optical powers, note the PSF is not a point, but often has rings common to multiple optical powers. Similarly, in the simulated retinal images notice various degrees of ghosting and doubling of the letters. Although not yet incorporated into a commercialized lens design some attempt has been explored to reduce the visibility of multiple images created by the multiple refractive zones by combining specific levels of aberration within the defocus introducing zones (e.g. opposite sign spherical aberration to that of the introduced defocus [325]. Additionally, recently, non-coaxial optical segments have been introduced in a myopia control lens design with the aim of providing myopic defocus, but defocus not focused on the optical axis, making the blur associated with this defocus less noticeable to the wearer [326, 327].

Figure 25.

Figure 25.

(Top row) The optical power of three sample theoretical lens designs for an 8 mm pupil; a multi-ring, dual-focus myopia control (left column), a lens with a center focused for near viewing optics (green and yellow) and surround for distant viewing optics (blue)(middle column), and a lens with a center focused for distance viewing optics (blue) and surround for near (green) (right column). (Middle row) The geometrical optics point spread function created by the three theoretical lenses as if viewing a distant source. (Bottom row) The simulated retinal image quality through these lenses of a 20/120 and 20/40 size letter.

An alternative way to ameliorate issues related to multiple images created by multiple lens zones or powers would be through lenses which proactively change their optical power, such as through electroactive lenses. Electroactive spectacles designed with a liquid crystal between the front and back lens surfaces were introduced in the early 2000s, but contact lens technology is now being explored [328]. Lens design, electrode material choices, communication, and power sources are key hurdles to address [301]. Several mechanisms to drive power change have been explored, including such novel ways as using electrooculographic signals from blinking to switch the display from a distance to near vision correcting optical power [328].

Electroactive lenses could be considered a subset of ‘smart’ contact lenses, which integrate active processes. Other smart lenses have been developed for diagnosis or treatment of disease, such as to monitor eye pressure [329], blood glucose [330], cancer [331], etc. They have also been developed to incorporate eye tracking or wireless eye-machine interaction [332]. Related, attempts with some reported early successes have been made to incorporate augmented reality into a soft contact lens (e.g. Mojo vision). However, no products have been fully realized or are yet commercially available.

Concluding remarks

Advances in manufacturing technology aim to keep pace with the increased demand for optical optimizations to enhance vision. These necessary technological advances also allow current biomedical technologies to accomplish more than their originally intended or singular functions and better improve condition or disease diagnosis, management, and treatment.

Acknowledgements

Kim Jedlicka, OD

19. Neurosciences applied to vision health

Stéphanie C Thébault

Laboratorio de Investigación Traslacional en Salud Visual (D-13), Instituto de Neurobiología, Universidad Nacional Autónoma de Mexico (UNAM), Querétaro, Mexico

E-mail: sthebault@comunidad.unam.mx

Status

Visual science is the model system of neuroscience, not only because visual paradigms are widely used to understand behavior and cognitive functions, but also because its results are relevant to all other fields, including molecular and cellular biology, cognitive science, ophthalmology, psychology, computer science, optometry, and education. The reader can consult the more than 100 book chapters that cover the historical foundations to the latest findings in visual neuroscience [333], a recent revision article in which among the nearly 40 000 publications in this field (almost 15 000 in the last 5 years), the 25 articles that have contributed most to the advancement of visual neurosciences have been reviewed [334], as well as the original works for more details.

A deeper understanding of the early wiring of the visual system, how the brain generates vision, and the effect of visual deprivation and plasticity will help translate basic research into effective approaches and treatments to prevent and repair visual impairment and dysfunction as shown schematically in figure 26. Visual deficiencies are characterized by a decrease in visual acuity and/or a restriction of the visual field. They have several stages, the most serious being blindness, and various causes. Glaucoma, macular degeneration, amblyopia (‘lazy eye’), myopia, are among the most notable types, while retinitis pigmentosa (RP) is the most common type of inherited retinal dystrophy.

Figure 26.

Figure 26.

Imaging of the retinal head and optic nerve and electrophysiological data are the basis for the diagnosis (Dx) of the main retinopathies, including diabetic retinopathy (DR), age-related macular degeneration (AMD) and retinitis pigmentosa (RP), but are also currently being studied extensively in the context of the differential diagnosis of psychiatric pathologies. These data are also used to predict the risk of cardiovascular, metabolic and kidney diseases.

Discoveries in visual neuroscience largely follow advances in microscopy, genetics, physiology, and data processing. For example, human genetic studies, the biochemical characterization of rhodopsin, the first G-protein-coupled receptor identified and the molecular substrate of phototransduction, the deciphering of retinal circuits combined with optogenetic therapy that transforms surviving cells into artificial photoreceptors, have recently enabled partial recovery of vision in a patient with RP [335].

Artificial intelligence-based models have become the tools of choice to predict the neural responses of any brain area, including the visual cortex [336], to any possible input stimulus, and to predict and detect neuro(retino)pathies based on retina and optic nerve head imaging data [337]. The nexus between retinal function and the brain has been very close lately because psychiatric disorders resulting from an imbalance in neurotransmitters, might be more stabilized if the optic nerves are sending balanced signals into the brain [338] and might be diagnosed thanks to visual system information [339]. Similarly, vision therapy for concussion-related vision disorders, strokes of the optic nerve or brain, and others benefits from incorporating biofeedback of the eye-brain connection [340].

Current and future challenges

The main lines of research of neurosciences applied to visual health are visual prostheses and the adapted use of natural strategies for the (re)generation of nervous tissue involved in vision and its function to recover vision loss associated with RP, macular degeneration, glaucoma, amblyopia [341] or other traumatic injuries. In addition to technological advances, these approaches require knowledge of the neural visual code and the early wiring mechanisms through which visual system is refined as shown in figure 27.

Figure 27.

Figure 27.

The degree of vision recovery in cases of inherited retinal dystrophies made possible by current visual prostheses (top scenario) should be significantly improved by complementing stimuli-evoked patterns of neuronal activity with data on neuroglial function, basal neuronal activity, genetic, clinical, physiological and environmental data, including the microbiome (bottom scenario).

Detailed characterization of the light responses of each retinal cell type to diverse visual stimuli has begun, but their diversity is staggering [342, 343]. The situation is somewhat similar within the thalamus and cortex [344]. The processing of low-level features like shape, curvature, contrast, and motion at the retinal level and its use by the brain remains to be understood to uncover coding principles of visual perception. Particularly, much remains to be clarified regarding how the perception (ventral) and action (dorsal) pathways interact, how feedback circuits modify these feedforward pathways, and to what extent such computations are distributed across visual hierarchy levels. Furthermore, artificial vision requires knowing how this code is altered in blind individuals and the effect of visual deprivation and plasticity [345], as well as adapting technologies that enable to read–write neuronal activity in vivo, at single-cell resolution [346348], to manipulate neuronal ensemble activity. Solutions for enlarging the visual field, increasing the visual field size, increasing spatial and temporal resolution of visual prostheses, and improving electrode–tissue interface are also needed [345].

An additional contribution of bioelectronic medicine is, as described in other nervous system areas [349], to complement neural visual code models with genetic, physiological, clinical, and environmental data specific to each individual to develop tailor-made therapeutic interventions. In addition to data privacy and security measures, a medium- to short-term challenge is to mitigate biases due to the sampled population and the technologies used for data collection [349].

In parallel, correcting mutations in the phototransduction machinery with gene therapy and genome-editing tools is a current challenge to interrupt or reverse many blinding disorders [350]. Stem cell therapy treatment strategy also shows promise in effectively improving vision loss related to macular degeneration [351].

Models of visual system function will also need to integrate other cell types than neurons, such as endothelial cells and neuroglia. They both play a leading role in neuromodulation, which encompasses the homeostatic support and immune defense of nervous tissue that have a direct impact on the pathogenesis of ocular neurodegenerative diseases, such as glaucoma, macular degeneration, and diabetic retinopathy [349, 352].

Advances in science and technology to meet challenges

Several research and technological opportunities can be seen in the field of neuroscience applied to visual health. The main ones are common to any neuroscience, others are particular to the visual system, notably the retina.

With the current availability of recordings of more than 1000 neurons at a time, the difficulty of analyzing these population data arises, the current analysis pipelines lead only to activity correlation. In addition to an easy access to a huge capacity for storing and processing information, there is therefore a growing need to develop programs and markers that evidence causal links, so that we might understand how population codes relate to distinct cell types and cell type-specific circuits in the visual system and, subsequently or in parallel, to decipher how all this neural code is decoded and converted into visual perception [353]. The retina poses the particular challenge of not being susceptible to optogenetics in the presence of functional photoreceptors. Some responses will have to wait for the development of time-specific retinal neuronal activation or inhibition by sonogenetics [354] for example. The picture will also be complete when field and unit recordings and analysis will consider intrinsic neuronal activity, also known as noise.

Once this decoding under physiological conditions will be complete, merging this knowledge with predictive models that closely monitor the evolution of visual dysfunction and visual impairment will likely offer invaluable insights in identifying key points of intervention and tailoring therapeutic approaches to counteract or slow the progression of these conditions. Real-time monitoring using wearable sensors and implantable devices is one of the advancements needed to provide continuous health data. Furthermore, computational models of human vision will be of huge help to the resolution of these goals, but we cannot forget that these are powered with organic data coming from humans or clinically relevant models.

Concluding remarks

One of the most striking facts about neurosciences applied to visual health is that the eye is at the forefront of developing therapies for genetic diseases [335].

Visual neurosciences contribute to visual and other organ (brain, heart, kidney) health. The eye-brain connection [339] will likely play a more prominent role in brain rehabilitation in the near future thanks to the growing emergence of neuro-optometry [355].

It is often stated that collaboration across disciplines is the key to deepening our understanding of the visual system function. It is also argued that transdisciplinary approaches allow us to apply the knowledge gained to understand disease mechanisms and develop treatments for the rapid diagnosis and repair of visual impairment, visual dysfunction, and blindness. Nevertheless, faced with the ocean of data and the neglect of certain lines of research [334], I come to wonder if achieving these noble goals might not also depend on not losing course and dedicating more time to coordinating ophthalmologists, optometrists, neuroscientists, biomedical engineers, etc. around central questions. Anyway, visual neuroscience has a long way to go and a bright future.

Acknowledgements

This research was supported by the UNAM-DGAPA PAPIIT Grant IN212823 and the National Council of Humanities, Science and Technology of Mexico (CONAHCYT) CF-2019-1759.

Contributor Information

Jesús E Gómez-Correa, Email: jgomez@inaoep.mx.

Brian Vohnsen, Email: brian.vohnsen@ucd.ie.

Barbara K Pierścionek, Email: barbara.pierscionek@aru.ac.uk.

Sabino Chávez-Cerda, Email: sabino@inaoep.mx.

Data availability statement

No new data were created or analysed in this study.

References

  • 1.Vohnsen B. A short history of optics. Phys. Scr. 2004;2004:75–79. doi: 10.1238/Physica.Topical.109a00075. [DOI] [Google Scholar]
  • 2.Darrigol O. A History of Optics from Greek Antiquity to the Nineteenth Century. Oxford University Press; 2012. [Google Scholar]
  • 3.Randleman J B, Zhang H, Asroui L, Tarib I, Dupps W J, Jr, Scarcelli G. Subclinical keratoconus detection and characterization using motion-tracking Brillouin microscopy. Ophthalmology. 2024;131:310–21. doi: 10.1016/j.ophtha.2023.10.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Lan G, Aglyamov S R, Larin K V, Twa M D. In vivo human corneal shear-wave optical coherence elastography. Optom. Vis. Sci. 2021;98:1. doi: 10.1097/OPX.0000000000001633. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Eliasy A, Chen K-J, Vinciguerra R, Lopes B T, Abass A, Vinciguerra P, Ambrósio R, Jr, Roberts C J, Elsheikh A. Determination of corneal biomechanical behavior in-vivo for healthy eyes using CorVis ST tonometry: stress-strain index. Front. Bioeng. Biotechnol. 2019;7:105. doi: 10.3389/fbioe.2019.00105. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Luce D A. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J. Cataract Refract. Surg. 2005;31:1. doi: 10.1016/j.jcrs.2004.10.044. [DOI] [PubMed] [Google Scholar]
  • 7.Flecha-Lescún J. Doctoral Dissertation. 2021. Computational planning tools in ophthalmology: intrastromal corneal ring surgery. [Google Scholar]
  • 8.Redaelli E, Nana M, Calvo B, Rodríguez Matas J F, Luraghi G, Rozema J, Grasa J. Improving early detection of keratoconus by non-contact tonometry: a computational study and new biomarkers proposal. J. Mech. Behav. Biomed. Mater. 2024;152:106413. doi: 10.1016/j.jmbbm.2024.106413. [DOI] [PubMed] [Google Scholar]
  • 9.Frigelli M, Büchler P, Kling S. Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography. Front. Bioeng. Biotechnol. 2024;11:1272097. doi: 10.3389/fbioe.2023.1272097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Lim W K, Soh Z D, Choi H K Y, Theng J T S. Epithelium-on photorefractive intrastromal cross-linking (PiXL) for reduction of low myopia. Clin. Ophthalmol. 2017;11:1205. doi: 10.2147/OPTH.S137712. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Shen M, Fan F, Xue A, Wang J, Zhou X, Lu F. Biomechanical properties of the cornea in high myopia. Vis. Res. 2008;48:2167–71. doi: 10.1016/j.visres.2008.06.020. [DOI] [PubMed] [Google Scholar]
  • 12.Wu W, Dou R, Wang Y. Comparison of corneal biomechanics between low and high myopic eyes—a meta-analysis. Am. J. Ophthalmol. 2019;207:419–25. doi: 10.1016/j.ajo.2019.07.007. [DOI] [PubMed] [Google Scholar]
  • 13.Han F, Li M, Wei P, Ma J, Jhanji V, Wang Y. Effect of biomechanical properties on myopia: a study of new corneal biomechanical parameters. BMC Ophthalmol. 2020;20:1–8. doi: 10.1186/s12886-020-01729-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Vinciguerra R, Ambrósio R, Elsheikh A, Roberts C J, Lopes B, Morenghi E, Azzolini C, Vinciguerra P. Detection of keratoconus with a new biomechanical index. J. Refractive Surg. 2016;32:803–10. doi: 10.3928/1081597X-20160629-01. [DOI] [PubMed] [Google Scholar]
  • 15.Ambrósio R, Jr, Lopes B T, Faria-Correia F, Salomão M Q, Bühren J, Roberts C J, Elsheikh A, Vinciguerra R, Vinciguerra P. Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection. J. Refractive Surg. 2017;33:434–43. doi: 10.3928/1081597X-20170426-02. [DOI] [PubMed] [Google Scholar]
  • 16.Zvietcovich F, Pongchalee P, Meemon P, Rolland J P, Parker K J. Reverberant 3D optical coherence elastography maps the elasticity of individual corneal layers. Nat. Commun. 2019;10:4895. doi: 10.1038/s41467-019-12803-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Kling S. In-vivo measurement of ocular deformation in response to ambient pressure modulation. Front. Bioeng. Biotechnol. 2021;9:1113. doi: 10.3389/fbioe.2021.759588. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Francis M, Khamar P, Shetty R, Sainani K, Nuijts R M M A, Haex B, Sinha Roy A. In vivo prediction of air-puff induced corneal deformation using LASIK, SMILE, and PRK finite element simulations. Invest. Ophthalmol. Vis. Sci. 2018;59:5320–8. doi: 10.1167/iovs.18-2470. [DOI] [PubMed] [Google Scholar]
  • 19.Beer F, Wartak A, Haindl R, Gröschl M, Baumann B, Pircher M, Hitzenberger C K. Conical scan pattern for enhanced visualization of the human cornea using polarization-sensitive OCT. Biomed. Opt. Express. 2017;8:2906–23. doi: 10.1364/BOE.8.002906. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Alexandrov S A, Subhash H M, Zam A, Leahy M. Nano-sensitive optical coherence tomography. Nanoscale. 2014;6:3545–9. doi: 10.1039/C3NR06132A. [DOI] [PubMed] [Google Scholar]
  • 21.Ghaderi H, Rozema J J. SyntEyes OBM: higher order statistical eye model for biomechanical analyses. Invest. Ophthalmol. Vis. Sci. 2024;65:3388. doi: 10.1167/iovs.15-18067. (available at: https://iovs.arvojournals.org/article.aspx?articleid=2795424) [DOI] [PubMed] [Google Scholar]
  • 22.Amorim A R, Bret B, González-Méijome J M. Opto-mechanical eye models: a review on human vision applications and perspectives for use in industry. Sensors. 2022;22:7686. doi: 10.3390/s22197686. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Godefrooij D A, De Wit G A, Uiterwaal C S, Imhof S M, Wisse R P. Age-specific incidence and prevalence of keratoconus: a nationwide registration study. Am. J. Ophthalmol. 2017;175:169–72. doi: 10.1016/j.ajo.2016.12.015. [DOI] [PubMed] [Google Scholar]
  • 24.Gordon-Shaag A, Millodot M, Shneor E. The epidemiology and etiology of keratoconus. Int. J. Keratoconus Ectatic Corneal Dis. 2012;70:7–15. (available at: www.ijkecd.com/doi/pdf/10.5005/jp-journals-10025-1002) [Google Scholar]
  • 25.Ferdi A C, Nguyen V, Gore D M, Allan B D, Rozema J J, Watson S L. Keratoconus natural progression: a systematic review and meta-analysis of 11,529 eyes. Ophthalmology. 2019;126:935–45. doi: 10.1016/j.ophtha.2019.02.029. [DOI] [PubMed] [Google Scholar]
  • 26.Hastings G D, Applegate R A, Nguyen L C, Kauffman M J, Hemmati R T, Marsack J D. Comparison of wavefront-guided and best conventional scleral lenses after habituation in eyes with corneal ectasia. Optom. Vis. Sci. 2019;96:238–47. doi: 10.1097/OPX.0000000000001365. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Applegate R A, Hastings G D, Jiménez-García M, Francis S, Koppen C, Rozema J J. Allowable movement of wavefront-guided contact lens corrections in normal and keratoconic eyes. Ophthalmic Physiol. Opt. 2024;44:746–56. doi: 10.1111/opo.13286. [DOI] [PubMed] [Google Scholar]
  • 28.Raiskup F, Herber R, Lenk J, Ramm L, Wittig D, Pillunat L E, Spoerl E. Corneal crosslinking with riboflavin and UVA light in progressive keratoconus: fifteen-year results. Am. J. Ophthalmol. 2023;250:95–102. doi: 10.1016/j.ajo.2023.01.022. [DOI] [PubMed] [Google Scholar]
  • 29.Koller T, Pajic B, Vinciguerra P, Seiler T. Flattening of the cornea after collagen crosslinking for keratoconus. J. Cataract Refract. Surg. 2011;37:1488–92. doi: 10.1016/j.jcrs.2011.03.041. [DOI] [PubMed] [Google Scholar]
  • 30.Seiler T G, Fischinger I, Koller T, Zapp D, Frueh B E, Seiler T. Customized corneal cross-linking: one-year results. Am. J. Ophthalmol. 2016;166:14–21. doi: 10.1016/j.ajo.2016.02.029. [DOI] [PubMed] [Google Scholar]
  • 31.Hastings G D, Marsack J D, Thibos L N, Applegate R A. Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size. J. Opt. Soc. Am. A. 2018;35:732–9. doi: 10.1364/JOSAA.35.000732. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.ANSI—The Vision Council . American National Standard for Ophthalmics: Methods for Reporting Optical Aberrations of Eyes. ANSI; 2022. [Google Scholar]
  • 33.Thibos L N, Applegate R A, Schwiegerling J T, Webb R. Standards for reporting the optical aberrations of eyes. Optom. Vis. Sci. 2002;18:S652–S60. doi: 10.3928/1081-597X-20020901-30. [DOI] [PubMed] [Google Scholar]
  • 34.Applegate R A, Ballentine C, Gross H, Sarver E J, Sarver C A. Visual acuity as a function of Zernike mode and level of root mean square error. Optom. Vis. Sci. 2003;80:97–105. doi: 10.1097/00006324-200302000-00005. [DOI] [PubMed] [Google Scholar]
  • 35.Applegate R A, Marsack J D, Ramos R, Sarver E J. Interaction between aberrations to improve or reduce visual performance. J. Cataract Refract. Surg. 2003;29:1487–95. doi: 10.1016/S0886-3350(03)00334-1. [DOI] [PubMed] [Google Scholar]
  • 36.Marsack J D, Thibos L N, Applegate R A. Metrics of optical quality derived from wave aberrations predict visual performance. J. Vis. 2004;4:8. doi: 10.1167/4.4.8. [DOI] [PubMed] [Google Scholar]
  • 37.Applegate R A, Marsack J D, Thibos L N. Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity. Optom. Vis. Sci. 2006;83:635–40. doi: 10.1097/01.opx.0000232842.60932.af. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Ravikumar A, Sarver E J, Applegate R A. Change in visual acuity is highly correlated with change in six image quality metrics independent of wavefront error and/or pupil diameter. J. Vis. 2012;12:11. doi: 10.1167/12.10.11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Williams D R. Aliasing in human foveal vision. Vis. Res. 1985;25:195–205. doi: 10.1016/0042-6989(85)90113-0. [DOI] [PubMed] [Google Scholar]
  • 40.Meek K M, Tuft S J, Huang Y, Gill P S, Hayes S, Newton R H, Bron A J. Changes in collagen orientation and distribution in keratoconus corneas. Investigative Ophthalmol. Vis. Sci. 2005;46:1948–56. doi: 10.1167/iovs.04-1253. [DOI] [PubMed] [Google Scholar]
  • 41.Morishige N, Wahlert A J, Kenney M C, Brown D J, Kawamoto K, Chikama T-I, Nishida T, Jester J V. Second-harmonic imaging microscopy of normal human and keratoconus cornea. Invest. Ophthalmol. Vis. Sci. 2007;48:1087–181. doi: 10.1167/iovs.06-1177. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Roberts C J, Dupps W J., Jr Biomechanics of corneal ectasia and biomechanical treatments. J. Cataract Refract. Surg. 2014;40:991–8. doi: 10.1016/j.jcrs.2014.04.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Chan E, Chong E W, Lee S S-Y, Franchina M, Yazar S, Eastwood P, McArdle N, Mackey D A, Lingham G. Incidence and prevalence of keratoconus based on Scheimpflug imaging. Ophthalmology. 2022;130:445–8. doi: 10.1016/j.ophtha.2022.11.027. [DOI] [PubMed] [Google Scholar]
  • 44.Holden B A, Fricke T R, Wilson D A, Jong M, Naidoo K S, Sankaridurg P, Wong T Y, Naduvilath T J, Resnikoff S. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology. 2016;123:1036–42. doi: 10.1016/j.ophtha.2016.01.006. [DOI] [PubMed] [Google Scholar]
  • 45.Burton M, et al. The lancet global health commission on global eye health: vision beyond 2020. Lancet Glob. Health. 2021;9:E489–551. doi: 10.1016/S2214-109X(20)30488-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Hersh P S, Stulting R D, Muller D, Durrie D S, Rajpal R K, Grp U S C S. United States multicenter clinical trial of corneal collagen crosslinking for keratoconus treatment. Ophthalmology. 2017;124:1259–70. doi: 10.1016/j.ophtha.2017.03.052. [DOI] [PubMed] [Google Scholar]
  • 47.Corcoran K J. Macroeconomic landscape of refractive surgery in the United States. Curr. Opin. Ophthalmol. 2015;26:249–54. doi: 10.1097/ICU.0000000000000159. [DOI] [PubMed] [Google Scholar]
  • 48.Lopes B, et al. Enhanced tomographic assessment to detect corneal ectasia based on artificial intelligence. Am. J. Ophthalmol. 2018;195:223–32. doi: 10.1016/j.ajo.2018.08.005. [DOI] [PubMed] [Google Scholar]
  • 49.Hatch K M, Ling J J, Wiley W F, Cason J, Ciralsky J B, Nehls S M, McCabe C M, Donnenfeld E D, Thompson V. Diagnosis and management of postrefractive surgery ectasia. J. Cataract Refract. Surg. 2022;48:487–99. doi: 10.1097/j.jcrs.0000000000000808. [DOI] [PubMed] [Google Scholar]
  • 50.Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest. Ophthalmol. Vis. Sci. 2007;48:3026–31. doi: 10.1167/iovs.04-0694. [DOI] [PubMed] [Google Scholar]
  • 51.Bak-Nielsen S, Pedersen I B, Ivarsen A, Hjortdal J. Dynamic Scheimpflug-based assessment of keratoconus and the effects of corneal cross-linking. J. Refractive Surg. 2014;30:408–14. doi: 10.3928/1081597X-20140513-02. [DOI] [PubMed] [Google Scholar]
  • 52.Tanter M, Touboul D, Gennisson J L, Bercoff J, Fink M. High-resolution quantitative imaging of cornea elasticity using supersonic shear imaging. IEEE Trans. Med. Imaging. 2009;28:1881–93. doi: 10.1109/TMI.2009.2021471. [DOI] [PubMed] [Google Scholar]
  • 53.Wang S, Larin K. Optical coherence elastography for tissue characterization: a review. J. Biophoton. 2015;8:279–302. doi: 10.1002/jbio.201400108. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Kabakova I, et al. Brillouin microscopy. Nat. Rev. Method Primen. 2024;48 doi: 10.1038/s43586-023-00286-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55.De Stefano V, Ford M, Seven I, Dupps W. Depth-dependent corneal biomechanical properties in normal and keratoconic subjects by optical coherence elastography. Transl. Vis. Sci. Technol. 2020;9:4. doi: 10.1167/tvst.9.7.4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Scarcelli G, Besner S, Pineda R, Kalout P, Yun S H. In vivo biomechanical mapping of normal and keratoconus corneas. JAMA Ophthalmol. 2015;133:480–2. doi: 10.1001/jamaophthalmol.2014.5641. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.Seiler T G, Shao P, Eltony A, Seiler T, Yun S H. Brillouin spectroscopy of normal and keratoconus corneas. Am. J. Ophthalmol. 2019;202:118–25. doi: 10.1016/j.ajo.2019.02.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Zhang H Y, Asroui L, Randleman J B, Scarcelli G. Motion-tracking Brillouin microscopy for in-vivo corneal biomechanics mapping. Biomed. Opt. Express. 2022;13:6196–210. doi: 10.1364/BOE.472053. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Randleman J, Zhang H, Asroui L, Tarib I, Dupps W, Scarcelli G. Subclinical keratoconus detection and characterization using motion-tracking Brillouin microscopy. Ophthalmology. 2024;131:310–21. doi: 10.1016/j.ophtha.2023.10.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Zhang H Y, Asroui L, Tarib I, Dupps W J, Scarcelli G, Randleman J B. Motion-tracking Brillouin microscopy evaluation of normal, keratoconic, and post-laser vision correction corneas. Am. J. Ophthalmol. 2023;254:128–40. doi: 10.1016/j.ajo.2023.03.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Pierscionek B K, Regini J W. The gradient index lens of the eye: an optobiological synchrony. Prog. Retin. Eye Res. 2012;31:332–249. doi: 10.1016/j.preteyeres.2012.03.001. [DOI] [PubMed] [Google Scholar]
  • 62.Sparrow J M, Bron A J, Brown N A, Ayliffe W, Hill A R. The Oxford clinical classification and grading system. Int. Ophthalmol. 1986;9:207–25. doi: 10.1007/BF00137534. [DOI] [PubMed] [Google Scholar]
  • 63.Morner C T. Untersuchungender protein-substanzen in den lichtbrechenden Medien des Auges. Z. Physiol. Chem. 1893;18:61–106. [Google Scholar]
  • 64.Lahm D, Lee L K, Bettelheim F A. Age dependence of freezable and nonfreezable water content of normal human lenses. Invest. Ophthalmol. Vis. Sci. 1985;26:1162–5. [PubMed] [Google Scholar]
  • 65.Bours J, Födisch H J, Hockwin O. Age-related changes in water and crystallin content of the fetal and adult human lens, demonstrated by a microsectioning technique. Ophthalmic Res. 1987;19:235–9. doi: 10.1159/000265500. [DOI] [PubMed] [Google Scholar]
  • 66.Mathias R T, Kistler J, Donaldson P J. The lens circulation. J. Membr. Biol. 2007;216:1–16. doi: 10.1007/s00232-007-9019-y. [DOI] [PubMed] [Google Scholar]
  • 67.Vorontsova I, Gehring I, Hall J E, Schilling T F. Aqp0a regulates suture stability in the zebrafish lens. Invest. Ophthalmol. Vis. Sci. 2018;59:2869–79. doi: 10.1167/iovs.18-24044. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 68.Wang K, Vorontsova I, Hoshino M, Uesugi K, Yagi N, Hall J E, Schilling T F, Pierscionek B K. Aquaporins have regional functions in the development of refractive index in the zebrafish eye lens. Invest. Ophthalmol. Vis. Sci. 2021;62:23. doi: 10.1167/iovs.62.3.23. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69.Cheng C, Wang K, Hoshino M, Uesugi K, Yagi N, Pierscionek B. EphA2 affects development of the eye lens nucleus and the gradient of refractive index. Invest. Ophthalmol. Vis. Sci. 2022;63:2. doi: 10.1167/iovs.63.1.2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Wang K, Hoshino M, Uesugi K, Yagi N, Young R D, Frost B E, Regini J W, Quantock A J, Pierscionek B K. Cell compaction is not required for the development of gradient refractive index profiles in the embryonic chick lens. Exp. Eye Res. 2020;197:108112. doi: 10.1016/j.exer.2020.108112. [DOI] [PubMed] [Google Scholar]
  • 71.Pierscionek B K, Bahrami M, Hoshino M, Uesugi K, Regini J, Yagi N. The eye lens: age-related trends and individual variations in refractive index and shape parameters. Oncotarget. 2015;31:30532–44. doi: 10.18632/oncotarget.5762. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 72.Cheng C, et al. Age-related changes in eye lens biomechanics, morphology, refractive index and transparency. Aging. 2019;11:12497–531. doi: 10.18632/aging.102584. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 73.Wang K, et al. Optical development in the murine eye lens of accelerated senescence-prone SAMP8 and senescence-resistant SAMR1 strains. Exp. Eye Res. 2024;241:109858. doi: 10.1016/j.exer.2024.109858. [DOI] [PubMed] [Google Scholar]
  • 74.Wang K, Hoshino M, Uesugi K, Yagi N, Pierscionek B K, Andley U P. Oxysterol compounds in mouse mutant αA- and αB-crystallin lenses can improve the optical properties of the lens. Invest. Ophthalmol. Vis. Sci. 2022;63:15. doi: 10.1167/iovs.63.5.15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 75.Pierscionek B K. Anti-cataract therapies: is there a need for a new approach based on targeting of aquaporins? Expert Opin. Ther. Targets. 2021;25:1027–31. doi: 10.1080/14728222.2021.2017423. [DOI] [PubMed] [Google Scholar]
  • 76.Atchison D A, Thibos L N. Optical models of the human eye. Clin. Exp. Optom. 2016;99:99–106. doi: 10.1111/cxo.12352. [DOI] [PubMed] [Google Scholar]
  • 77.Esteve-Taboada J J, Montés-Micó R, Ferrer-Blasco T. Schematic eye models to mimic the behavior of the accommodating human eye. J. Cataract Refract. Surg. 2018;44:627–41. doi: 10.1016/j.jcrs.2018.02.024. [DOI] [PubMed] [Google Scholar]
  • 78.Artal P, editor. Handbook of Visual Optics: Fundamentals and Eye Optics. vol 1. CRC Press; 2017. [Google Scholar]
  • 79.Atchison D A, Smith G. Optics of the Human Eye. Butterworth-Heinemann; 2000. [Google Scholar]
  • 80.Emsley H H. Visual Optics. 1952. (Hatton Press Ltd) [Google Scholar]
  • 81.Le Grand Y, El Hage S G. Physiological Optics. Springer-Verlag; 1980. [Google Scholar]
  • 82.Helmholtz H. Helmholtz’s Treatise on Physiological Optics. vol 1. Dover; 1962. [Google Scholar]
  • 83.Popiolek-Masajada A, Kasprzak H T. A new schematic eye model incorporating accommodation. Optom. Vis. Sci. 1999;76:720–7. doi: 10.1097/00006324-199910000-00024. [DOI] [PubMed] [Google Scholar]
  • 84.Kasprzak H T. New approximation for the whole profile of the human crystalline lens. Ophthalmic Physiol. Opt. 2000;20:31–43. doi: 10.1046/j.1475-1313.2000.00475.x. [DOI] [PubMed] [Google Scholar]
  • 85.Liu T, Thibos L N. Customized models of ocular aberrations across the visual field during accommodation. J. Vis. 2019;19:13. doi: 10.1167/19.9.13. [DOI] [PubMed] [Google Scholar]
  • 86.Huang Y, Moore D T. Human eye modeling using a single equation of gradient index crystalline lens for relaxed and accommodated states. Proc. SPIE. 2006;6342:634201 [Google Scholar]
  • 87.Díaz J A, Pizarro C, Arasa J. Single dispersive gradient-index profile for the aging human lens. J. Opt. Soc. Am. A. 2008;25:250–61. doi: 10.1364/JOSAA.25.000250. [DOI] [PubMed] [Google Scholar]
  • 88.Jaimes-Nájera A, Gómez-Correa J E, Coello V, Pierscionek B K, Chávez-Cerda S. Single function crystalline lens capable of mimicking ciliary body accommodation. Biomed. Opt. Express. 2020;11:3699–716. doi: 10.1364/BOE.386459. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 89.Gómez-Correa J E, Balderas-Mata S E, Pierscionek B K, Chávez-Cerda S. Composite modified Luneburg model of human eye lens. Opt. Lett. 2015;40:3990–3. doi: 10.1364/OL.40.003990. [DOI] [PubMed] [Google Scholar]
  • 90.Gómez-Correa J E, Coello V, Garza-Rivera A, Puente N P, Chávez-Cerda S. Three-dimensional ray tracing in spherical and elliptical generalized Luneburg lenses for application in the human eye lens. Appl. Opt. 2016;55:2002–10. doi: 10.1364/AO.55.002002. [DOI] [PubMed] [Google Scholar]
  • 91.Navarro R, Palos F, González L. Adaptive model of the gradient index of the human lens. I. Formulation and model of aging ex vivo lenses. J. Opt. Soc. Am. A. 2007;24:2175–85. doi: 10.1364/JOSAA.24.002175. [DOI] [PubMed] [Google Scholar]
  • 92.Navarro R, Palos F, González L M. Adaptive model of the gradient index of the human lens. II. Optics of the accommodating aging lens. J. Opt. Soc. Am. A. 2007;24:2911–20. doi: 10.1364/JOSAA.24.002911. [DOI] [PubMed] [Google Scholar]
  • 93.Popiolek-Masajada A, Kasprzak H. Model of the optical system of the human eye during accommodation. Ophthalmic Physiol. Opt. 2002;22:201–8. doi: 10.1046/j.1475-1313.2002.00024.x. [DOI] [PubMed] [Google Scholar]
  • 94.Sheil C J, Goncharov A V. Accommodating volume-constant age-dependent optical (AVOCADO) model of the crystalline GRIN lens. Biomed. Opt. Express. 2016;7:1985–99. doi: 10.1364/BOE.7.001985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 95.Liou H L, Brennan N A. Anatomically accurate, finite model eye for optical modeling. J. Opt. Soc. Am. A. 1997;14:1684–95. doi: 10.1364/JOSAA.14.001684. [DOI] [PubMed] [Google Scholar]
  • 96.Jaimes-Nájera A, Gómez-Correa J E, Coello V, Pierscionek B K, Chávez-Cerda S. A single-function model for the eye’s crystalline lens. Opt. Photon. News. 2020;31:54. doi: 10.1364/OPN.31.12.000054. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 97.Navarro R, López-Gil N. Impact of internal curvature gradient on the power and accommodation of the crystalline lens. Optica. 2017;4:334–40. doi: 10.1364/OPTICA.4.000334. [DOI] [Google Scholar]
  • 98.Khan A, Pope J M, Verkicharla P K, Suheimat M, Atchison D A. Change in human lens dimensions, lens refractive index distribution and ciliary body ring diameter with accommodation. Biomed. Opt. Express. 2018;9:1272–82. doi: 10.1364/BOE.9.001272. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 99.Moffat B A, Atchison D A, Pope J M. Age-related changes in refractive index distribution and power of the human lens as measured by magnetic resonance micro-imaging in vitro. Vis. Res. 2002;42:1683–93. doi: 10.1016/S0042-6989(02)00078-0. [DOI] [PubMed] [Google Scholar]
  • 100.Helmholtz H. Handbook of Physiological Optics. 1866. (L. Voss) [Google Scholar]
  • 101.Southwell W. Ray tracing in gradient-index media. J. Opt. Soc. Am. 1982;72:908–11. doi: 10.1364/JOSA.72.000908. [DOI] [Google Scholar]
  • 102.Beliakov G, Chan D Y C. Analysis of inhomogeneous optical systems by the use of ray tracing. I. Planar systems. Appl. Opt. 1997;36:5303–9. doi: 10.1364/AO.36.005303. [DOI] [PubMed] [Google Scholar]
  • 103.Sheil C, Goncharov A. Crystalline lens paradoxes revisited: significance of age-related restructuring of the GRIN. Biomed. Opt. Express. 2017;8:4172–80. doi: 10.1364/BOE.8.004172. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 104.Charman W N. The eye in focus: accommodation and presbyopia. Clin. Exp. Optom. 2008;91:207–25. doi: 10.1111/j.1444-0938.2008.00256.x. [DOI] [PubMed] [Google Scholar]
  • 105.Manns F, Ho A. Paraxial equivalent of the gradient-index lens of the human eye. Biomed. Opt. Express. 2022;13:5131–50. doi: 10.1364/BOE.464121. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 106.Navarro R, Lockett-Ruiz V, López J L. Analytical ray transfer matrix for the crystalline lens. Biomed. Opt. Express. 2022;13:5836–48. doi: 10.1364/BOE.466374. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 107.Flynn C, Goncharov A. Semi-analytical finite ray-tracing through the quadratic symmetric GRIN lens. Appl. Opt. 2024;63:290–8. doi: 10.1364/AO.504305. [DOI] [PubMed] [Google Scholar]
  • 108.Lakshimarayanan V, Ghatsk A K, Thyagarajan K. Lagrangian Optics. Kluwer Academic; 2002. [Google Scholar]
  • 109.McKeon B, Goncharov A. Symplectic numerical methods in optics and imaging: ray tracing in spherical gradient-index lenses and computer-generated image rendering. Appl. Opt. 2023;62:8621–31. doi: 10.1364/AO.501102. [DOI] [PubMed] [Google Scholar]
  • 110.Goncharov A, Nowakowski M, Sheehan M, Dainty C. Reconstruction of the optical system of the human eye with reverse ray-tracing. Opt. Express. 2008;16:1692–703. doi: 10.1364/OE.16.001692. [DOI] [PubMed] [Google Scholar]
  • 111.Wei X, Thibos L. Modeling the eye’s optical system by ocular wavefront tomography. Opt. Express. 2008;16:20490–502. doi: 10.1364/OE.16.020490. [DOI] [PubMed] [Google Scholar]
  • 112.Polans J, Jaeken B, McNabb R, Artal P, Izatt J. Wide-field optical model of the human eye with asymmetrically tilted and decentered lens that reproduces measured ocular aberrations. Optica. 2015;2:124–34. doi: 10.1364/OPTICA.2.000124. [DOI] [Google Scholar]
  • 113.Bahrami M, Hoshino M, Pierscionek B, Yagi N, Regini J, Uesugi K. Optical properties of the lens: an explanation for the zones of discontinuity. Exp. Eye Res. 2014;124:93–99. doi: 10.1016/j.exer.2014.05.009. [DOI] [PubMed] [Google Scholar]
  • 114.Bahrami M, Goncharov A. Geometry-invariant GRIN lens: finite ray tracing. Opt. Express. 2014;22:27797–810. doi: 10.1364/OE.22.027797. [DOI] [PubMed] [Google Scholar]
  • 115.de Castro A, Ortiz S, Gambra E, Siedlecki D, Marcos S. Three-dimensional reconstruction of the crystalline lens gradient index distribution from OCT imaging. Opt. Express. 2010;18:21905–17. doi: 10.1364/OE.18.021905. [DOI] [PubMed] [Google Scholar]
  • 116.Ruggeri M, et al. System for on- and off-axis volumetric OCT imaging and ray tracing aberrometry of the crystalline lens. Biomed. Opt. Express. 2018;9:3834–51. doi: 10.1364/BOE.9.003834. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 117.Qiu C, Maceo Heilman B, Kaipio J, Donaldson P, Vaghefi E. Fully automated laser ray tracing system to measure changes in the crystalline lens GRIN profile. Biomed. Opt. Express. 2017;8:4947–64. doi: 10.1364/BOE.8.004947. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 118.de Castro A, Birkenfeld J, Heilman B, Ruggeri M, Arrieta E, Parel J, Manns F, Marcos S. Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods. Biomed. Opt. Express. 2019;10:3622–34. doi: 10.1364/BOE.10.003622. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 119.Curcio C A, Sloan K R, Kalina R E, Hendrickson A E. Human photoreceptor topography. J. Comparative Neurol. 1990;292:497–523. doi: 10.1002/cne.902920402. [DOI] [PubMed] [Google Scholar]
  • 120.Mazzoni F, Safa H, Finnemann S C. Understanding photoreceptor outer segment phagocytosis: use and utility of RPE cells in culture. Exp. Eye Res. 2014;126:51–60. doi: 10.1016/j.exer.2014.01.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 121.Enoch J M. Optical properties of retinal receptors. J. Opt. Soc. Am. 1963;53:71–85. doi: 10.1364/JOSA.53.000071. [DOI] [Google Scholar]
  • 122.Vohnsen B, Iglesias I, Artal P. Guided light and diffraction model of human-eye photoreceptors. J. Opt. Soc. Am. A. 2005;22:2318–28. doi: 10.1364/JOSAA.22.002318. [DOI] [PubMed] [Google Scholar]
  • 123.Vohnsen B. Directional sensitivity of the retina: a layered scattering model of outer-segment photoreceptor pigments. Biomed. Opt. Express. 2014;5:1569–87. doi: 10.1364/BOE.5.001569. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 124.Ball J M, Chen S, Li W. Mitochondria in cone photoreceptors act as microlenses to enhance photon delivery and confer directional sensitivity to light. Sci. Adv. 2022;8:eabn2070. doi: 10.1126/sciadv.abn2070. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 125.Stiles W S, Crawford B H. The luminous efficiency of rays entering the eye pupil at different points. Proc. R. Soc. 1933;112:428–50. doi: 10.1098/rspb.1933.0020. [DOI] [Google Scholar]
  • 126.Westheimer G. Directional sensitivity of the retina: 75 years of Stiles–Crawford effect. Proc. R. Soc. B. 2008;275:2777–86. doi: 10.1098/rspb.2008.0712. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 127.Vohnsen B, Carmichael A, Sharmin N, Qaysi S, Valente D. Volumetric integration model of the Stiles-Crawford effect of the first kind and its experimental verification. J. Vis. 2017;17:18. doi: 10.1167/17.12.18. [DOI] [PubMed] [Google Scholar]
  • 128.Stiles W S. The luminous efficiency of monochromatic rays entering the eye pupil at different points and a new colour effect. Proc. R. Soc. B. 1937;123:90–118. doi: 10.1098/rspb.1937.0045. [DOI] [Google Scholar]
  • 129.Vohnsen B. The retina and the Stiles–Crawford effects in. In: Artal P, editor. Handbook of Visual Optics, Volume One: Fundamentals and Eye Optics. CRC Press; 2017. [Google Scholar]
  • 130.Artal P, Chen L, Fernández E J, Singer B, Manzanera S, Williams D R. Neural compensation for the eye’s optical aberrations. J. Vis. 2004;4:281–7. doi: 10.1167/4.4.4. [DOI] [PubMed] [Google Scholar]
  • 131.Boyle K C, Chen Z C, Ling T, Pandiyan V P, Kuchenbecker J, Sabesan R, Palanker D. Mechanisms of light-induced deformations in photoreceptors. Biophys. J. 2020;119:1481–8. doi: 10.1016/j.bpj.2020.09.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 132.Tomczewski S, Węgrzyn P, Borycki D, Auksorius E, Wojtkowski M, Curatolo A. Light-adapted flicker optoretinograms captured with a spatio-temporal optical coherence-tomography (STOC-T) system. Biomed. Opt. Express. 2022;13:2186–201. doi: 10.1364/BOE.444567. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 133.Warner R L, Brainard D H, Morgan J I W. Repeatability and reciprocity of the cone optoretinogram. Biomed. Opt. Express. 2022;13:6561–73. doi: 10.1364/BOE.471990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 134.Smallman H S, MacLeod D I A, Doyle P. Realignment of cones after cataract removal. Nature. 2001;412:604–5. doi: 10.1038/35088126. [DOI] [PubMed] [Google Scholar]
  • 135.Eckmiller M S. Defective cone photoreceptor cytoskeleton, alignment, feedback, and energetics can lead to energy depletion in macular degeneration. Prog. Retin. Eye Res. 2004;23:495–522. doi: 10.1016/j.preteyeres.2004.04.005. [DOI] [PubMed] [Google Scholar]
  • 136.Vohnsen B. Geometrical scaling of the developing eye and photoreceptors and a possible relation to emmetropization and myopia. Vis. Res. 2021;189:46–53. doi: 10.1016/j.visres.2021.09.002. [DOI] [PubMed] [Google Scholar]
  • 137.Witten J L, Lukyanova V, Harmening W M. Sub-cone visual resolution by active, adaptive sampling in the human foveola. eLife. 2024;13:1–19. doi: 10.7554/eLife.98648.3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 138.Ryle J P, Vohnsen B, Sheridan J T. Simultaneous drift, microsaccades, and ocular microtremor measurement from a single noncontact far-field optical sensor. J. Biomed. Opt. 2014;20:027004. doi: 10.1117/1.JBO.20.2.027004. [DOI] [PubMed] [Google Scholar]
  • 139.Artal P, Manzanera S. Perceived brightness with small apertures. J. Cataract Refract. Surg. 2018;44:734–7. doi: 10.1016/j.jcrs.2018.03.032. [DOI] [PubMed] [Google Scholar]
  • 140.Vohnsen B. The impact of aberrations in a 3D retinal model eye. Proc. SPIE. 2021;11814:1–6. [Google Scholar]
  • 141.Fitzpatrick A, Vohnsen B. Leakage of light and its relation to the Stiles-Crawford effects of the first and second kind using an array of cylindrical absorbers as retinal phantom. Investigative Ophthalmol. Vis. Sci. 2024;65:5450. [Google Scholar]
  • 142.Swiatczak B, Schaeffel F. Myopia: why the retina stops inhibiting eye growth. Sci. Rep. 2022;12:21704. doi: 10.1038/s41598-022-26323-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 143.Rozema J, Dankert S, Iribarren R. Emmetropization and nonmyopic eye growth. Surv. Ophthalmol. 2023;68:759–83. doi: 10.1016/j.survophthal.2023.02.002. [DOI] [PubMed] [Google Scholar]
  • 144.Youdelis C, Hendrickson A. A qualitative and quantitative analysis of the human fovea during development. Vis. Res. 1986;26:847–55. doi: 10.1016/0042-6989(86)90143-4. [DOI] [PubMed] [Google Scholar]
  • 145.Laties A M, Enoch J M. An analysis of retinal receptor orientation. I. Angular relationship of neighboring photoreceptors. Investigative Ophthalmol. 1971;10:69–77. [PubMed] [Google Scholar]
  • 146.Valente D, Vohnsen B. Retina-simulating phantom produced by photolithography. Opt. Lett. 2017;42:4623–6. doi: 10.1364/OL.42.004623. [DOI] [PubMed] [Google Scholar]
  • 147.Morgan J I W, Chui T Y P, Grieve K. Twenty-five years of clinical applications using adaptive optics ophthalmoscopy. Biomed. Opt. Express. 2023;14:387–428. doi: 10.1364/BOE.472274. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 148.Chew E Y, et al. Standardization and clinical applications of retinal imaging biomarkers for cardiovascular disease: a Roadmap from an NHLBI workshop. Nat. Rev. Cardiol. 2025;22:47–63. doi: 10.1038/s41569-024-01060-8. (available at: www.nature.com/articles/s41569-024-01060-8) [DOI] [PubMed] [Google Scholar]
  • 149.Yuan Y, Dong M, Wen S, Yuan X, Zhou L. Retinal microcirculation: a window into systemic circulation and metabolic disease. Exp. Eye Res. 2024;242:109885. doi: 10.1016/j.exer.2024.109885. [DOI] [PubMed] [Google Scholar]
  • 150.Suh A, Ong J, Kamran S A, Waisberg E, Paladugu P, Zaman N, Sarker P, Tavakkoli A, Lee A G. Retina oculomics in neurodegenerative disease. Ann. Biomed. Eng. 2023;51:2708–21. doi: 10.1007/s10439-023-03365-0. [DOI] [PubMed] [Google Scholar]
  • 151.Morgan J I. The fundus photo has met its match: optical coherence tomography and adaptive optics ophthalmoscopy are here to stay. Ophthalmic Physiol. Opt. 2016;36:218–39. doi: 10.1111/opo.12289. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 152.Webb R H, Hughes G W. Scanning laser ophthalmoscope. IEEE Trans. Biomed. Eng. 1981;28:488–92. doi: 10.1109/TBME.1981.324734. [DOI] [PubMed] [Google Scholar]
  • 153.Huang D, et al. Optical coherence tomography. Science. 1991;254:1178–81. doi: 10.1126/science.1957169. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 154.Liang J, Williams D R, Miller D T. Supernormal vision and high-resolution retinal imaging through adaptive optics. J. Opt. Soc. Am. A. 1997;14:2884–92. doi: 10.1364/JOSAA.14.002884. [DOI] [PubMed] [Google Scholar]
  • 155.Roorda A, Romero-Borja F, Donnelly W J, Queener H, Hebert T J, Campbell M C W. Adaptive optics scanning laser ophthalmoscopy. Opt. Express. 2002;10:405–12. doi: 10.1364/OE.10.000405. [DOI] [PubMed] [Google Scholar]
  • 156.Zhang Y, Rha J, Jonnal R, Miller D. Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina. Opt. Express. 2005;13:4792–811. doi: 10.1364/OPEX.13.004792. [DOI] [PubMed] [Google Scholar]
  • 157.Morgan J I W, Dubra A, Wolfe R, Merigan W H, Williams D R. In vivo autofluorescence imaging of the human and macaque retinal pigment epithelial cell mosaic. Invest. Ophthalmol. Vis. Sci. 2009;50:1350–9. doi: 10.1167/iovs.08-2618. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 158.Tam J, Martin J A, Roorda A. Noninvasive visualization and analysis of parafoveal capillaries in humans. Invest. Ophthalmol. Vis. Sci. 2010;51:1691–8. doi: 10.1167/iovs.09-4483. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 159.Tuten W S, Tiruveedhula P, Roorda A. Adaptive optics scanning laser ophthalmoscope-based microperimetry. Optom. Vis. Sci. 2012;89:563–74. doi: 10.1097/OPX.0b013e3182512b98. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 160.Cooper R F, Tuten W S, Dubra A, Brainard D H, Morgan J I W. Non-invasive assessment of human cone photoreceptor function. Biomed. Opt. Express. 2017;8:5098–112. doi: 10.1364/BOE.8.005098. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 161.Pandiyan V P, Maloney-Bertelli A, Kuchenbecker J A, Boyle K C, Ling T, Chen Z C, Park B H, Roorda A, Palanker D, Sabesan R. The optoretinogram reveals the primary steps of phototransduction in the living human eye. Sci. Adv. 2020;6:eabc1124. doi: 10.1126/sciadv.abc1124. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 162.Pfaffle C, Spahr H, Gercke K, Puyo L, Höhl S, Melenberg D, Miura Y, Hüttmann G, Hillmann D. Phase-sensitive measurements of depth-dependent signal transduction in the inner plexiform layer. Front. Med. 2022;9:885187. doi: 10.3389/fmed.2022.885187. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 163.Jonnal R S, Rha J, Zhang Y, Cense B, Gao W, Miller D T. In vivo functional imaging of human cone photoreceptors. Opt. Express. 2007;15:16141–60. doi: 10.1364/OE.15.016141. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 164.Lassoued A, Zhang F, Kurokawa K, Liu Y, Bernucci M T, Crowell J A, Miller D T. Cone photoreceptor dysfunction in retinitis pigmentosa revealed by optoretinography. Proc. Natl Acad. Sci. USA. 2021;118:e2107444118. doi: 10.1073/pnas.2107444118. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 165.Xu P, Cooper R F, Jiang Y Y, Morgan J I W. Parafoveal cone function in choroideremia assessed with adaptive optics optoretinography. Sci. Rep. 2024;14:8339. doi: 10.1038/s41598-024-58059-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 166.Roorda A, Williams D R. The arrangement of the three cone classes in the living human eye. Nature. 1999;397:520–2. doi: 10.1038/17383. [DOI] [PubMed] [Google Scholar]
  • 167.Liu Z, Kurokawa K, Zhang F, Lee J J, Miller D T. Imaging and quantifying ganglion cells and other transparent neurons in the living human retina. Proc. Natl Acad. Sci. USA. 2017;114:12803–8. doi: 10.1073/pnas.1711734114. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 168.Williams D R, Burns S A, Miller D T, Roorda A. Evolution of adaptive optics retinal imaging. Biomed. Opt. Express. 2023;14:1307–38. doi: 10.1364/BOE.485371. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 169.Marcos S, Artal P, Atchison D A, Hampson K, Legras R, Lundstrom L, Yoon G. Adaptive optics visual simulators: a review of recent optical designs and applications. Biomed. Opt. Express. 2022;13:6508–32. doi: 10.1364/BOE.473458. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 170.Harmening W M, Tuten W S, Roorda A, Sincich L C. Mapping the perceptual grain of the human retina. J. Neurosci. 2014;34:5667–77. doi: 10.1523/JNEUROSCI.5191-13.2014. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 171.Tuten W S, Vergilio G K, Young G J, Bennett J, Maguire A M, Aleman T S, Brainard D H, Morgan J I W. Visual function at the atrophic border in choroideremia assessed with adaptive optics microperimetry. Ophthalmol. Retina. 2019;3:888–99. doi: 10.1016/j.oret.2019.05.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 172.Zhang F, Kurokawa K, Lassoued A, Crowell J A, Miller D T. Cone photoreceptor classification in the living human eye from photostimulation-induced phase dynamics. Proc. Natl Acad. Sci. USA. 2019;116:7951–6. doi: 10.1073/pnas.1816360116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 173.Wang Y, Bensaid N, Tiruveedhula P, Ma J, Ravikumar S, Roorda A. Human foveal cone photoreceptor topography and its dependence on eye length. Elife. 2019;8:e47148. doi: 10.7554/eLife.47148. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 174.Wilk M A, Dubis A M, Cooper R F, Summerfelt P, Dubra A, Carroll J. Assessing the spatial relationship between fixation and foveal specializations. Vis. Res. 2017;132:53–61. doi: 10.1016/j.visres.2016.05.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 175.Carroll J, et al. Cone photoreceptor mosaic disruption associated with Cys203Arg mutation in the M-cone opsin. Proc. Natl Acad. Sci. USA. 2009;106:20948–53. doi: 10.1073/pnas.0910128106. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 176.Pinhas A, et al. Assessment of perfused foveal microvascular density and identification of nonperfused capillaries in healthy and vasculopathic eyes. Invest. Ophthalmol. Vis. Sci. 2014;55:8056–66. doi: 10.1167/iovs.14-15136. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 177.Sharma R, Schwarz C, Hunter J J, Palczewska G, Palczewski K, Williams D R. Formation and clearance of all-trans-retinol in rods investigated in the living primate eye with two-photon ophthalmoscopy. Invest. Ophthalmol. Vis. Sci. 2017;58:604–13. doi: 10.1167/iovs.16-20061. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 178.Duan A, Bedggood P A, Bui B V, Metha A B. Evidence of flicker-induced functional hyperaemia in the smallest vessels of the human retinal blood supply. PLoS One. 2016;11:e0162621. doi: 10.1371/journal.pone.0162621. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 179.Joseph A, Chu C J, Feng G, Dholakia K, Schallek J. Label-free imaging of immune cell dynamics in the living retina using adaptive optics. Elife. 2020;9:e60547. doi: 10.7554/eLife.60547. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 180.Godat T, Kohout K, Parkins K, Yang Q, McGregor J E, Merigan W H, Williams D R, Patterson S S. Cone-opponent ganglion cells in the primate fovea tuned to noncardinal color directions. J. Neurosci. 2024;44:e1738232024. doi: 10.1523/JNEUROSCI.1738-23.2024. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 181.Lu R, Aguilera N, Liu T, Liu J, Giannini J P, Li J, Bower A J, Dubra A, Tam J. In-vivo sub-diffraction adaptive optics imaging of photoreceptors in the human eye with annular pupil illumination and sub-Airy detection. Optica. 2021;8:333–43. doi: 10.1364/OPTICA.414206. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 182.Scoles D, Sulai Y N, Langlo C S, Fishman G A, Curcio C A, Carroll J, Dubra A. In vivo imaging of human cone photoreceptor inner segments. Invest. Ophthalmol. Vis. Sci. 2014;55:4244–51. doi: 10.1167/iovs.14-14542. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 183.Tam J, Liu J, Dubra A, Fariss R N. In vivo imaging of the human retinal pigment epithelial mosaic using adaptive optics enhanced indocyanine green ophthalmoscopy. Invest. Ophthalmol. Vis. Sci. 2016;57:4376–84. doi: 10.1167/iovs.16-19503. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 184.Fong J, et al. Novel color via stimulation of individual photoreceptors at population scale. Sci. Adv. 2025;11:eadu1052. doi: 10.1126/sciadv.adu1052. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 185.Geng Y, Dubra A, Yin L, Merigan W H, Sharma R, Libby R T, Williams D R. Adaptive optics retinal imaging in the living mouse eye. Biomed. Opt. Express. 2012;3:715–34. doi: 10.1364/BOE.3.000715. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 186.Wang Y, La T T, Mason M, Tuten W S, Roorda A. Case report: multimodal, longitudinal assessment of retinal structure and function following laser retinal injury. Optom. Vis. Sci. 2023;100:281–8. doi: 10.1097/OPX.0000000000002004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 187.Tabernero J. Customised eye models. In: Artal P, editor. Handbook of Visual Optics: Fundamentals and Eye Optics. vol 1. CRC Press; 2017. pp. 337–47. [Google Scholar]
  • 188.Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol. 2007;85:472–85. doi: 10.1111/j.1755-3768.2007.00879.x. [DOI] [PubMed] [Google Scholar]
  • 189.Wang Q, Jiang W, Lin T, Zhu Y, Chen C, Lin H, Chen W. Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis. Clin. Exp. Ophthalmol. 2018;46:738–49. doi: 10.1111/ceo.13184. [DOI] [PubMed] [Google Scholar]
  • 190.Thibos L N, Bradley A, Hong X. A statistical model of the aberration structure of normal, well-corrected eyes. Ophthalmic Physiol. Opt. 2002;22:427–33. doi: 10.1046/j.1475-1313.2002.00059.x. [DOI] [PubMed] [Google Scholar]
  • 191.Rozema J J, Rodriguez P, Navarro R, Tassignon M-J. SyntEyes: a higher-order statistical eye model for healthy eyes. Invest. Ophthalmol. Vis. Sci. 2016;57:683–91. doi: 10.1167/iovs.15-18067. [DOI] [PubMed] [Google Scholar]
  • 192.Rozema J J, Rodriguez P, Ruiz Hidalgo I, Navarro R, Tassignon M J, Koppen C. SyntEyes KTC: higher order statistical eye model for developing keratoconus. Ophthalmic Physiol. Opt. 2017;37:358–65. doi: 10.1111/opo.12369. [DOI] [PubMed] [Google Scholar]
  • 193.Durkee H, Ruggeri M, Rohman L, Williams S, Ho A, Parel J-M, Manns F. Dynamic refraction and anterior segment OCT biometry during accommodation. Biomed. Opt. Express. 2024;15:2876–89. doi: 10.1364/BOE.512193. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 194.Hung G K, Ciuffreda K J. Model of human refractive error development. Curr. Eye Res. 1999;19:41–52. doi: 10.1076/ceyr.19.1.41.5343. [DOI] [PubMed] [Google Scholar]
  • 195.Schaeffel F, Swiatczak B. Mechanisms of emmetropization and what might go wrong in myopia. Vis. Res. 2024;220:108402. doi: 10.1016/j.visres.2024.108402. [DOI] [PubMed] [Google Scholar]
  • 196.Smith G, Atchison D A. The Eye and Visual Optical Instruments. 1997. (Cambridge University Press) [Google Scholar]
  • 197.Smith G, Atchison D A, Iskander D R, Jones C E, Pope J M. Mathematical models for describing the shape of the in vitro unstretched human crystalline lens. Vis. Res. 2009;49:2442–52. doi: 10.1016/j.visres.2009.07.014. [DOI] [PubMed] [Google Scholar]
  • 198.Navarro R, Santamaría J, Bescós J. Accommodation-dependent model of the human eye with aspherics. J. Opt. Soc. Am. A. 1985;2:1273–81. doi: 10.1364/JOSAA.2.001273. [DOI] [PubMed] [Google Scholar]
  • 199.Rogel-Salazar J, Treviño J P, Chávez-Cerda S. Engineering structured light with optical vortices. J. Opt. Soc. Am. B. 2014;31:A46–A50. doi: 10.1364/JOSAB.31.000A46. [DOI] [Google Scholar]
  • 200.Lakshminarayanan V, Fleck A. Zernike polynomials: a guide. J. Mod. Opt. 2011;58:545–61. doi: 10.1080/09500340.2011.554896. [DOI] [Google Scholar]
  • 201.Gbur G J. Mathematical Methods for Optical Physics and Engineering. Cambridge University Press; 2011. [Google Scholar]
  • 202.Trevino J P, Gómez-Correa J E, Iskander D R, Chávez-Cerda S. Zernike vs. Bessel circular functions in visual optics. Ophthalmic Physiol. Opt. 2013;33:394. doi: 10.1111/opo.12065. [DOI] [PubMed] [Google Scholar]
  • 203.Li S, Zhang S. Numerical model of the influence function of deformable mirrors based on Bessel Fourier orthogonal functions. Res. Astron. Astrophys. 2014;14:1504–10. doi: 10.1088/1674-4527/14/11/013. [DOI] [Google Scholar]
  • 204.Gómez-Correa J E, Platas-Garza M A, Trevino J P, Jaimes-Nájera A, Padilla-Ortiz A L, Galaviz-Mosqueda A, Coello V, Rogel-Salazar J, Chávez-Cerda S. Topographic synthesis of arbitrary surfaces with vortex Jinc functions. Appl. Opt. 2020;59:D95–D103. doi: 10.1364/AO.383157. [DOI] [PubMed] [Google Scholar]
  • 205.Babcock H W. The possibility of compensating astronomical seeing. Publ. Astron. Soc. Pac. 1953;65:229–36. doi: 10.1086/126606. [DOI] [Google Scholar]
  • 206.Noll R J. Zernike polynomials and atmospheric turbulence. J. Opt. Soc. Am. 1976;66:207–11. doi: 10.1364/JOSA.66.000207. [DOI] [Google Scholar]
  • 207.Schwiegerling J T, Greivenkamp J E. Using corneal height maps and polynomial decomposition to determine corneal aberrations. Optom. Vis. Sci. 1997;74:916. doi: 10.1097/00006324-199711000-00024. [DOI] [PubMed] [Google Scholar]
  • 208.Levene J R. The true inventors of the keratoscope and photo-keratoscope. Br. J. Hist. Sci. 1965;2:324–42. doi: 10.1017/S000708740000248X. [DOI] [PubMed] [Google Scholar]
  • 209.Doss J, Hutson R, Rowsey J, Brown D R. Method for calculation of corneal profile and power distribution. Arch. Ophthalmol. 1981;99:1261–5. doi: 10.1001/archopht.1981.03930020135018. [DOI] [PubMed] [Google Scholar]
  • 210.Iskander D R, Morelande M R, Collins M J. A refined bootstrap method for estimating the Zernike polynomial model order for corneal surfaces. IEEE Trans. Biomed. Eng. 2004;51:2203–6. doi: 10.1109/TBME.2004.834252. [DOI] [PubMed] [Google Scholar]
  • 211.Maile H, et al. Machine learning algorithms to detect subclinical keratoconus:systematic review. JMIR Med. Inform. 2021;9:e27363. doi: 10.2196/27363. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 212.Nuliqiman M, Xu M, Sun Y, Cao J, Chen P, Gao Q, Xu P, Ye J. Artificial intelligence in ophthalmic surgery: current applications and expectations. Clin. Ophthalmol. 2023;17:3499–511. doi: 10.2147/OPTH.S438127. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 213.Mahajan V N, Dai G. Orthonormal polynomials in wavefront analysis: analytical solution. J. Opt. Soc. Am. A. 2007;24:2994–3016. doi: 10.1364/JOSAA.24.002994. [DOI] [PubMed] [Google Scholar]
  • 214.Martínez-Enríquez E, de Castro A, Marcos S. Eigenlenses: a new model for full crystalline lens shape representation and its applications. Biomed. Opt. Express. 2020;11:5633–49. doi: 10.1364/BOE.397695. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 215.Martínez-Enríquez E, Curatolo A, de Castro A, Birkenfeld J S, González A M, Mohamed A, Ruggeri M, Manns F, Fernando Z, Marcos S. Estimation of the full shape of the crystalline lens in vivo from OCT images using eigenlenses. Biomed. Opt. Express. 2023;14:608–26. doi: 10.1364/BOE.477557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 216.Waisberg E, Ong J, Kamran S A, Masalkhi M, Paladugu P, Zaman N, Lee A G, Tavakkoli A. Generative artificial intelligence in ophthalmology. Surv. Ophthalmol. 2025;70:1–11. doi: 10.1016/j.survophthal.2024.04.009. [DOI] [PubMed] [Google Scholar]
  • 217.Vater C, Wolfe B, Rosenholtz R. Peripheral vision in real-world tasks: a systematic review. Psychon Bull. Rev. 2022;29:1531–57. doi: 10.3758/s13423-022-02117-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 218.Lundström L, Rosén R. Peripheral aberrations. In: Artal P, editor. Handbook of Visual Optics, Volume One, Fundamentals and Eye Optics. 1st. CRC Press; 2017. pp. 313–35. ch. 21. [Google Scholar]
  • 219.Venkataraman A P, Rosén R, Heredia A A, Piers P, Vidal C C, Lundström L. Peripheral vision and hazard detection with average phakic and pseudophakic optical errors. Biomed. Opt. Express. 2021;12:3082–90. doi: 10.1364/BOE.419120. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 220.Ortiz-Peregrina S, Casares-López M, Castro-Torres J J, Anera R G, Artal P. Effect of peripheral refractive errors on driving performance. Biomed. Opt. Express. 2022;13:5533–50. doi: 10.1364/BOE.468032. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 221.Troilo D, et al. IMI—report on experimental models of emmetropization and myopia. Invest. Ophthalmol. Vis. Sci. 2019;60:M31–M88. doi: 10.1167/iovs.18-25967. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 222.Wildsoet C F, et al. IMI—interventions for controlling myopia onset and progression report. Invest. Ophthalmol. Vis. Sci. 2019;60:M106–M31. doi: 10.1167/iovs.18-25958. [DOI] [PubMed] [Google Scholar]
  • 223.Atchison D A, Charman W N. Optics of spectacle lenses intended to treat myopia progression. Optom. Vis. Sci. 2024;101:238–49. doi: 10.1097/OPX.0000000000002140. [DOI] [PubMed] [Google Scholar]
  • 224.Tabernero J, Vazquez D, Seidemann A, Uttenweiler D, Schaeffel F. Effects of myopic spectacle correction and radial refractive gradient spectacles on peripheral refraction. Vis. Res. 2009;49:2176–86. doi: 10.1016/j.visres.2009.06.008. [DOI] [PubMed] [Google Scholar]
  • 225.Jaeken B, Mirabet S, Marín J M, Artal P. Comparison of the optical image quality in the periphery of phakic and pseudophakic eyes. Invest. Ophthalmol. Vis. Sci. 2013;54:3594–9. doi: 10.1167/iovs.13-11956. [DOI] [PubMed] [Google Scholar]
  • 226.Lundström L, Mira-Agudelo A, Artal P. Peripheral optical errors and their change with accommodation differ between emmetropic and myopic eyes. J. Vis. 2009;9:17.1–17. doi: 10.1167/9.6.17. [DOI] [PubMed] [Google Scholar]
  • 227.Tabernero J, Schaeffel F. Fast scanning photoretinoscope for measuring peripheral refraction as a function of accommodation. J. Opt. Soc. Am. A. 2009;26:2206. doi: 10.1364/JOSAA.26.002206. [DOI] [PubMed] [Google Scholar]
  • 228.Smith G, Millodot M, McBrien N. The effect of accommodation on oblique astigmatism and field curvature of the human eye. Clin. Exp. Optom. 1988;71:119–25. doi: 10.1111/j.1444-0938.1988.tb04331.x. [DOI] [Google Scholar]
  • 229.Romashchenko D, Lundström L. Dual-angle open field wavefront sensor for simultaneous measurements of the central and peripheral human eye. Biomed. Opt. Express. 2020;11:3125–38. doi: 10.1364/BOE.391548. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 230.Pusti D, Kendrick C D, Wu Y, Ji Q, Jung H W, Yoon G. Widefield wavefront sensor for multidirectional peripheral retinal scanning. Biomed. Opt. Express. 2023;14:4190–204. doi: 10.1364/BOE.491412. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 231.Wei X, Thibos L. Design and validation of a scanning Shack Hartmann aberrometer for measurements of the eye over a wide field of view. Opt. Express. 2010;18:1134–43. doi: 10.1364/OE.18.001134. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 232.Fernandez E J, Sager S, Lin Z, Hao J, Roca J, Prieto P M, Yang Z, Lan W, Artal P. Instrument for fast whole-field peripheral refraction in the human eye. Biomed. Opt. Express. 2022;13:2947–59. doi: 10.1364/BOE.457686. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 233.Jaeken B, Lundström L, Artal P. Fast scanning peripheral wave-front sensor for the human eye. Opt. Express. 2011;19:7903–13. doi: 10.1364/OE.19.007903. [DOI] [PubMed] [Google Scholar]
  • 234.Fedtke C, Ehrmann K, Falk D, Bakaraju R C, Holden B A. The BHVI-EyeMapper: peripheral refraction and aberration profiles. Optom. Vis. Sci. 2014;91:1199–207. doi: 10.1097/OPX.0000000000000364. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 235.Yequan H, Jingyun G, Yu G, Yan C, Zhechuang L, Xuechuan D, Xiaolin N. A focusing method on refraction topography measurement. Sci. Rep. 2023;13:16440. doi: 10.1038/s41598-023-42950-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 236.Papadogiannis P, Börjeson C, Lundström L. Comparison of optical myopia control interventions: effect on peripheral image quality and vision. Biomed. Opt. Express. 2023;14:3125–37. doi: 10.1364/BOE.486555. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 237.Smirnov M S. Measurement of the wave aberration of the human eye. Biofizika. 1961;6:776–95. [PubMed] [Google Scholar]
  • 238.Berny F, Slansky S. Wavefront determination resulting from Foucault test as applied to the human eye and visual instruments. Opt. Instrum. Tech. 1969;375:386. [Google Scholar]
  • 239.Howland B, Howland H C. Subjective measurement of high-order aberrations of the eye. Science. 1976;193:580–2. doi: 10.1126/science.959814. [DOI] [PubMed] [Google Scholar]
  • 240.Liang J, Grimm B, Goelz S, Bille J F. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. J. Opt. Soc. Am. A. 1994;11:1949–57. doi: 10.1364/JOSAA.11.001949. [DOI] [PubMed] [Google Scholar]
  • 241.Liang J, Williams D R. Aberrations and retinal image quality of the normal human eye. J. Opt. Soc. Am. A. 1997;14:2873–83. doi: 10.1364/JOSAA.14.002873. [DOI] [PubMed] [Google Scholar]
  • 242.Navarro R, Losada M A. Aberrations and relative efficiency of light pencils in the living human eye. Optom. Vis. Sci. 1997;74:540–7. doi: 10.1097/00006324-199707000-00023. [DOI] [PubMed] [Google Scholar]
  • 243.Mrochen M, Kaemmerer M, Mierdel P, Krinke H E, Seiler T. Principles of Tscherning aberrometry. J. Refract. Surg. 2000;16:S570–S1. doi: 10.3928/1081-597X-20000901-16. [DOI] [PubMed] [Google Scholar]
  • 244.MacRae S, Fujieda M. Slit skiascopic-guided ablation using the Nidek laser. J. Refract. Surg. 2000;16:S576–S80. doi: 10.3928/1081-597X-20000901-18. [DOI] [PubMed] [Google Scholar]
  • 245.Chiesa S, Dainty J C. Calibration and performance of a pyramid wavefront sensor for the eye. J. Mod. Opt. 2012;59:1415–27. doi: 10.1080/09500340.2012.717641. [DOI] [Google Scholar]
  • 246.Yoon G, Macrae S, Williams D R, Cox I G. Causes of spherical aberration induced by laser refractive surgery. J. Cataract Refract. Surg. 2005;31:127–35. doi: 10.1016/j.jcrs.2004.10.046. [DOI] [PubMed] [Google Scholar]
  • 247.Sabesan R, Johns L, Tomashevskaya O, Jacobs D S, Rosenthal P, Yoon G. Wavefront-guided scleral lens prosthetic device for keratoconus. Optom. Vis. Sci. 2013;90:314–23. doi: 10.1097/OPX.0b013e318288d19c. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 248.Koh S, Tung C, Aquavella J, Yadav R, Zavislan J, Yoon G. Simultaneous measurement of tear film dynamics using wavefront sensor and optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 2010;51:3441–8. doi: 10.1167/iovs.09-4430. [DOI] [PubMed] [Google Scholar]
  • 249.Pantanelli S, MacRae S, Jeong T M, Yoon G. Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor. Ophthalmology. 2007;114:2013–21. doi: 10.1016/j.ophtha.2007.01.008. [DOI] [PubMed] [Google Scholar]
  • 250.Donnelly W J, 3rd, Pesudovs K, Marsack J D, Sarver E J, Applegate R A. Quantifying scatter in Shack-Hartmann images to evaluate nuclear cataract. J. Refract. Surg. 2004;20:S515–22. doi: 10.3928/1081-597X-20040901-21. [DOI] [PubMed] [Google Scholar]
  • 251.Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang S P, Yoon G, Artal P. Simulating outcomes of cataract surgery: important advances in ophthalmology. Annu. Rev. Biomed. Eng. 2021;23:277–306. doi: 10.1146/annurev-bioeng-082420-035827. [DOI] [PubMed] [Google Scholar]
  • 252.Ji Q, Yoo Y S, Alam H, Yoon G. Through-focus optical characteristics of monofocal and bifocal soft contact lenses across the peripheral visual field. Ophthalmic Physiol. Opt. 2018;38:326–36. doi: 10.1111/opo.12452. [DOI] [PubMed] [Google Scholar]
  • 253.Bang S P, Jung H, Li K Y, Yoon G. Comparison of modal and zonal wavefront measurements of refractive extended depth of focus intraocular lenses. Biomed. Opt. Express. 2024;15:1618–29. doi: 10.1364/BOE.513529. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 254.Panagopoulou S I, Neal D R. Zonal matrix iterative method for wavefront reconstruction from gradient measurements. J. Refract. Surg. 2005;21:S563–9. doi: 10.3928/1081-597X-20050901-28. [DOI] [PubMed] [Google Scholar]
  • 255.Sabesan R, Yoon G. Visual performance after correcting higher order aberrations in keratoconic eyes. J. Vis. 2009;9:6. doi: 10.1167/9.5.6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 256.Thibos L N, Hong X, Bradley A, Applegate R A. Accuracy and precision of objective refraction from wavefront aberrations. J. Vis. 2004;4:329–51. doi: 10.1167/4.4.9. [DOI] [PubMed] [Google Scholar]
  • 257.Bang S P, Lyu J, Ng C J, Yoon G. Visual axis and Stiles–Crawford effect peak show a positional correlation in normal eyes: a cohort study. Investigative Ophthalmol. Vis. Sci. 2022;63:26. doi: 10.1167/iovs.63.11.26. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 258.Eddaif L, Shaban A. Fundamentals of sensor technology. In: Barhoum A, Altintas Z, editors. Advanced Sensor Technology. Elsevier; 2023. pp. 17–49. ch 2. [Google Scholar]
  • 259.Baffou G. Quantitative phase microscopy using quadriwave lateral shearing interferometry (QLSI): principle, terminology, algorithm and grating shadow description. J. Appl. Phys. 2021;54:294002. doi: 10.1088/1361-6463/abfbf9. [DOI] [Google Scholar]
  • 260.Bonaque-Gonzalez S, et al. The optics of the human eye at 8.6 microm resolution. Sci. Rep. 2021;11:23334. doi: 10.1038/s41598-021-02653-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 261.Jung H W, Bang S, Pusti D, Yoon G. High-speed Shack-Hartmann ocular wavefront sensor using an InGaAs sensor. Investigative Ophthalmol. Vis. Sci. 2023;64:2888. [Google Scholar]
  • 262.Asejczyk-Widlicka M, Pierscionek B K. Fluctuations in intraocular pressure and the potential effect on aberrations of the eye. Br. J. Ophthalmol. 2007;91:1054–8. doi: 10.1136/bjo.2006.109793. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 263.Jóźwik A, Asejczyk-Widlicka M, Kurzynowski P, Pierscionek B K. How a dynamic optical system maintains image quality: self-adjustment of the human eye. J. Vis. 2021;21:6. doi: 10.1167/jov.21.3.6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 264.Chakraborty R, Read S A, Collins M J. Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics. Invest. Ophthalmol. Vis. Sci. 2011;52:5121–9. doi: 10.1167/iovs.11-7364. [DOI] [PubMed] [Google Scholar]
  • 265.Hoffmann E M, et al. Intraocular pressure and its relation to ocular geometry: results from the Gutenberg health study. Invest. Ophthalmol. Vis. Sci. 2022;63:40. doi: 10.1167/iovs.63.1.40. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 266.Wang Q, Thau A, Levin A V, Lee D. Ocular hypotony: a comprehensive review. Surv. Ophthalmol. 2019;64:619–38. doi: 10.1016/j.survophthal.2019.04.006. [DOI] [PubMed] [Google Scholar]
  • 267.Stamper R L. A history of intraocular pressure and its measurement. Optom. Vis. Sci. 2011;88:E16–E28. doi: 10.1097/OPX.0b013e318205a4e7. [DOI] [PubMed] [Google Scholar]
  • 268.Da Silva F, Lira M. Intraocular pressure measurement: a review. Surv. Ophthalmol. 2022;67:1319–31. doi: 10.1016/j.survophthal.2022.03.001. [DOI] [PubMed] [Google Scholar]
  • 269.Liu J, Roberts C J. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J. Cataract Refract. Surg. 2005;31:146–55. doi: 10.1016/j.jcrs.2004.09.031. [DOI] [PubMed] [Google Scholar]
  • 270.Cook J A, Botello A P, Elders A, Fathi Ali A, Azuara-Blanco A, Fraser C, McCormack K, Margaret Burr J. Systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology. 2012;119:1552–7. doi: 10.1016/j.ophtha.2012.02.030. [DOI] [PubMed] [Google Scholar]
  • 271.Wu Y, Luttrell I, Feng S, Chen P P, Spaide T, Lee A Y, Wen J C. Development and validation of a machine learning, smartphone-based tonometer. Br. J. Ophthalmol. 2020;104:1394–8. doi: 10.1136/bjophthalmol-2019-315446. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 272.Alonso-Caneiro D, Karnowski K, Kaluzny B J, Kowalczyk A, Wojtkowski M. Assessment of corneal dynamics with high-speed swept source optical coherence tomography combined with an air puff system. Opt. Express. 2011;19:14188–99. doi: 10.1364/OE.19.014188. [DOI] [PubMed] [Google Scholar]
  • 273.Maczynska E, Rzeszewska-Zamiara J, Jimenez Villar A, Wojtkowski M, Kaluzny B J, Grulkowski I. Air-puff-induced dynamics of ocular components measured with optical biometry. Invest. Ophthalmol. Vis. Sci. 2019;60:1979–86. doi: 10.1167/iovs.19-26681. [DOI] [PubMed] [Google Scholar]
  • 274.Curatolo A, et al. Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities. Biomed. Opt. Express. 2020;11:6337–55. doi: 10.1364/BOE.402402. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 275.Sanchez I, Ortiz-Toquero S, Martin R. Intrasession repeatability and intersession reproducibility measurements using VX120 multidiagnostic unit. Eye Contact Lens. 2018;44:S266–S72. doi: 10.1097/ICL.0000000000000486. [DOI] [PubMed] [Google Scholar]
  • 276.Bagga H, Liu J H K, Weinreb R N. Intraocular pressure measurements throughout the 24 h. Curr. Opin. Ophthalmol. 2009;20:79–83. doi: 10.1097/ICU.0b013e32831eef4f. [DOI] [PubMed] [Google Scholar]
  • 277.Quérat L, Chen E. Impact of self-tonometry on glaucoma treatment decision. Acta Ophthalmol. 2023;101:e246–e51. doi: 10.1111/aos.15256. [DOI] [PubMed] [Google Scholar]
  • 278.Araci I E, Su B, Quake S R, Mandel Y. An implantable microfluidic device for self-monitoring of intraocular pressure. Nat. Med. 2014;20:1074–8. doi: 10.1038/nm.3621. [DOI] [PubMed] [Google Scholar]
  • 279.Kim J, et al. A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure. Nat. Biomed. Eng. 2021;5:772–82. doi: 10.1038/s41551-021-00719-8. [DOI] [PubMed] [Google Scholar]
  • 280.Wu K Y, Mina M, Carbonneau M, Marchand M, Tran S D. Advancements in wearable and implantable intraocular pressure biosensors for ophthalmology: a comprehensive review. Micromachines. 2023;14:1915. doi: 10.3390/mi14101915. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 281.Shean R, Yu N, Guntipally S, Nguyen V, He X, Duan S, Gokoffski K, Zhu Y, Xu B. Advances and challenges in wearable glaucoma diagnostics and therapeutics. Bioengineering. 2024;11:138. doi: 10.3390/bioengineering11020138. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 282.Lee S-H, Shin K-S, Kim J-W, Kang J-Y, Kim J-K. Stimulus-responsive contact lens for IOP measurement or temperature-triggered drug release. Transl. Vis. Sci. Technol. 2020;9:1. doi: 10.1167/tvst.9.4.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 283.Liu Y, Chen X. Surgical outcomes of phacoemulsification with different fluidics systems (centurion with active sentry vs. centurion gravity) in cataract patients with eye axial length above 26 mm. Front. Med. 2025;12:1554832. doi: 10.3389/fmed.2025.1554832. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 284.Zahabi S, Salimibani M, Jóźwik A, Asejczyk M. Impact of material property modifications on optical performance: a multidisciplinary study in the human eye under different intraocular pressures. Biomed. Opt. Express. 2025;16:2254–74. doi: 10.1364/BOE.555315. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 285.Zhang D, et al. A review of intraocular pressure (IOP) and axial myopia. J. Ophthalmol. 2022;2022:5626479. doi: 10.1155/2022/5626479. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 286.Ishii K, et al. Predicting intraocular pressure using systemic variables or fundus photography with deep learning in a health examination cohort. Sci. Rep. 2021;11:3687. doi: 10.1038/s41598-020-80839-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 287.Remón L, Pérez-Merino P, Macedo-de Araújo R J, Amorim-de Sousa A I, González-Méijome J M. Bifocal and multifocal contact lenses for presbyopia and myopia control. J. Ophthalmol. 2020;2020:8067657. doi: 10.1155/2020/8067657. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 288.Barbero S, Del Mar González M. Admissible surfaces in progressive addition lenses. Opt. Lett. 2020;45:5656–9. doi: 10.1364/OL.401927. [DOI] [PubMed] [Google Scholar]
  • 289.Alonso J, Quiroga J A. Modern Ophthalmic Optics. Cambridge University Press; 2019. [Google Scholar]
  • 290.Kołodziejczyk A, Bará S, Jaroszewicz Z, Sypek M. The light sword optical element—a new diffraction structure with extended depth of focus. J. Mod. Opt. 1990;37:1283–6. doi: 10.1080/09500349014551431. [DOI] [Google Scholar]
  • 291.Barbero S, Ritoré M. Extended-depth-of-focus wavefront design from pseudo-umbilical space curves. J. Opt. Soc. Am. A. 2023;40:1933–9. doi: 10.1364/JOSAA.501282. [DOI] [PubMed] [Google Scholar]
  • 292.Fernández D, Barbero S, Dorronsoro C, Marcos S. Multifocal intraocular lens providing optimized through-focus performance. Opt. Lett. 2013;38:5303–6. doi: 10.1364/OL.38.005303. [DOI] [PubMed] [Google Scholar]
  • 293.Guo H, Goncharov A V, Dainty C. Comparison of retinal image quality with spherical and customized aspheric intraocular lenses. Biomed. Opt. Express. 2012;3:681–91. doi: 10.1364/BOE.3.000681. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 294.Yi F, Iskander D R, Collins M J. Estimation of the depth of focus from wavefront measurements. J. Vis. 2010;10:1–9. doi: 10.1167/10.4.3. [DOI] [PubMed] [Google Scholar]
  • 295.Vila R, Portilla J, Barbero S. Robust numerical solution to the Levi-Civita wavefront coupling problem via level set computation of the point characteristic function. J. Opt. Soc. Am. A. 2023;40:277–84. doi: 10.1364/JOSAA.478404. [DOI] [PubMed] [Google Scholar]
  • 296.Hee-Dong J, Hyuntai K, Seung-Yeol L. Review of metasurfaces with extraordinary flat optic functionalities. Curr. Opt. Photon. 2024;8:16–29. doi: 10.3807/COPP.2024.8.1.16. [DOI] [Google Scholar]
  • 297.Na K S, Lee C S, Kim D R, Song S H, Cho S Y, Kim E C, Kim H S, Hwang H S. Development of a novel multifocal lens using a polarization directed flat lens: possible candidate for a multifocal intraocular lens. BMC Ophthalmic. 2021;21:444. doi: 10.1186/s12886-021-02191-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 298.Lee S, Park G, Kim S, Ryu Y, Yoon J W, Hwang H S, Song I S, Lee C S, Song S H. Geometric-phase intraocular lenses with multifocality. Light Sci. Appl. 2022;11:320. doi: 10.1038/s41377-022-01016-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 299.Shaker L M, Al-Amiery A, Isahak W N R W, Al-Azzawi W K. Metasurface contact lenses: a futuristic leap in vision enhancement. J. Opt. 2023 doi: 10.1007/s12596-023-01322-7. [DOI] [Google Scholar]
  • 300.Galstian T, Asatryan K, Presniakov V, Zohrabyan A, Tork A, Bagramyan A, Careau S, Thiboutot M, Cotovanu M. High optical quality electrically variable liquid crystal lens using an additional floating electrode. Opt. Lett. 2016;41:3265–8. doi: 10.1364/OL.41.003265. [DOI] [PubMed] [Google Scholar]
  • 301.Bailey J, Morgan P B, Gleeson H F, Jones J C. Switchable liquid crystal contact lenses for the correction of presbyopia. Crystals. 2018;8:29. doi: 10.3390/cryst8010029. [DOI] [Google Scholar]
  • 302.Gomez M A, Snow J C. How to construct liquid-crystal spectacles to control vision of real-world objects and environments. Behav. Res. Methods. 2024;56:563–76. doi: 10.3758/s13428-023-02059-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 303.Sauer Y, Künstle D-E, Wichmann F A, Wahl S. An objective measurement approach to quantify the perceived distortions of spectacle lenses. Sci. Rep. 2024;14:3967. doi: 10.1038/s41598-024-54368-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 304.Jian H, Zeng H. Existence and uniqueness for variational problem from progressive lens design. Front. Math. China. 2020;15:491–505. doi: 10.1007/s11464-020-0845-x. [DOI] [Google Scholar]
  • 305.Barbero S, Del Mar González M. Presbyopia correction, differential geometry, and free boundary PDEs. Not. Am. Math. Soc. 2023;70:1763–71. [Google Scholar]
  • 306.Casanellas J C G. Using interior point solvers for optimizing progressive lens models with spherical coordinates. Optim. Eng. 2020;21:1389–421. doi: 10.1007/s11081-019-09480-z. [DOI] [Google Scholar]
  • 307.Navarro R, Artal P, Williams D R. Modulation transfer of the human eye as a function of retinal eccentricity. J. Opt. Soc. Am. A. 1993;10:201–12. doi: 10.1364/JOSAA.10.000201. [DOI] [PubMed] [Google Scholar]
  • 308.Millodot M. Peripheral refraction in aphakic eyes. Am. J. Optom. Physiol. Opt. 1984;61:586–9. doi: 10.1097/00006324-198409000-00008. [DOI] [PubMed] [Google Scholar]
  • 309.Togka A, Livir-Rallatos A, Christaras D, Tsoukalas S, Papasyfakis N, Artal P, Ginis H. Peripheral image quality in pseudophakic eyes. Biomed. Opt. Express. 2020;11:1892. doi: 10.1364/BOE.387254. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 310.Artal P, Arvaniti M, Dimou P, Stavrinos C, Ginis H, Hervella L, Güell J L. Peripheral vision in patients following intraocular lens implantation: a systematic review and meta-analysis. Am. J. Ophthalmol. 2024;264:120–34. doi: 10.1016/j.ajo.2024.03.016. [DOI] [PubMed] [Google Scholar]
  • 311.García-Pedreño C, Tabernero J, Benito A, Artal P. Impact of peripheral refractive errors in mobility performance. Invest. Ophthalmol. Vis. Sci. 2024;65:42. doi: 10.1167/iovs.65.6.42. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 312.Artal P, Ginis H, Christaras D, Villegas E A, Tabernero J, Prieto P M. Inverted meniscus intraocular lens as a better optical surrogate of the crystalline lens. Biomed. Opt. Express. 2023;14:2129–37. doi: 10.1364/BOE.490089. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 313.Villegas E A, Marín J M, Ginis H, Robles C, Alcón E, Hervella L, Prieto P M, Taña-Rivero P, Artal P. Peripheral refraction and contrast detection sensitivity in pseudophakic patients implanted with a new meniscus intraocular lens. J. Refract. Surg. 2022;38:229–34. doi: 10.3928/1081597X-20220113-01. [DOI] [PubMed] [Google Scholar]
  • 314.Thibos L N, Hong X, Bradley A, Cheng X. Statistical variation of aberration structure and image quality in a normal population of healthy eyes. J. Opt. Soc. Am. A. 2002;19:2329–48. doi: 10.1364/JOSAA.19.002329. [DOI] [PubMed] [Google Scholar]
  • 315.Kollbaum P S, Bradley A, Thibos L N. Comparing the optical properties of soft contact lenses on and off the eye. Optom. Vis. Sci. 2013;90:924–36. doi: 10.1097/01.opx.0000434275.93435.da. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 316.Plainis S, Atchison D A, Charman W N. Power profiles of multifocal contact lenses and their interpretation. Optom. Vis. Sci. 2013;90:1066–77. doi: 10.1097/OPX.0000000000000030. [DOI] [PubMed] [Google Scholar]
  • 317.Kim E, Bakaraju R C, Ehrmann K. Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses. J. Optom. 2016;9:126–36. doi: 10.1016/j.optom.2015.10.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 318.Ares J, Flores R, Bará S, Jaroszewicz Z. Presbyopia compensation with a quartic axicon. Optom. Vis. Sci. 2005;82:1071–8. doi: 10.1097/01.opx.0000192347.57764.4c. [DOI] [PubMed] [Google Scholar]
  • 319.Kakarenko K, Ducin I, Grabowiecki K, Jaroszewicz Z, Kolodziejczyk A, Mira-Agudelo A, Petelczyc K, Składowska A, Sypek M. Assessment of imaging with extended depth-of-field by means of the light sword lens in terms of visual acuity scale. Biomed. Opt. Express. 2015;6:1738–48. doi: 10.1364/BOE.6.001738. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 320.Romero L A, Millán M S, Jaroszewicz Z, Kolodziejczyk A. Double peacock eye optical element for extended focal depth imaging with ophthalmic applications. J. Biomed. Opt. 2012;17:046013. doi: 10.1117/1.JBO.17.4.046013. [DOI] [PubMed] [Google Scholar]
  • 321.Smith E L, Ramamirtham R, Qiao-Grider Y, Hung L-F, Huang J, Kee C-S, Coats D, Paysse E. Effects of foveal ablation on emmetropization and form-deprivation myopia. Invest. Ophthalmol. Vis. Sci. 2007;48:3914–22. doi: 10.1167/iovs.06-1264. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 322.Walther G, Meyer D, Richards J, Rickert M, Kollbaum P. On-eye centration of soft contact lenses. Ophthalmic Physiol. Opt. 2024;44:737–45. doi: 10.1111/opo.13278. [DOI] [PubMed] [Google Scholar]
  • 323.Guirao A, Cox I G, Williams D R. Method for optimizing the correction of the eye’s higher-order aberrations in the presence of decentrations. J. Opt. Soc. Am. A. 2002;19:126–8. doi: 10.1364/JOSAA.19.000126. [DOI] [PubMed] [Google Scholar]
  • 324.Richdale K, et al. CLEAR—contact lens optics. Cont. Lens Anterior Eye. 2021;44:220–39. doi: 10.1016/j.clae.2021.02.005. [DOI] [PubMed] [Google Scholar]
  • 325.Bradley A, Kollbaum P, Thibos L. Multifocal correction providing improved quality of vision. 2017 United States Patent Appl. 13/405,395.
  • 326.Sah R P, Meyer D, Jaskulski M, Rickert M, Cheng X, Brennan N, Kollbaum P S. Impact of zone geometry on the introduction of myopic defocus in young adult eyes wearing multi-zone lenses. Ophthalmic Physiol. Opt. 2023;43:1110–24. doi: 10.1111/opo.13182. [DOI] [PubMed] [Google Scholar]
  • 327.Brennan N, et al. Pulsed plus lens designs for myopia control, enhanced depth of focus and presbyopia correction. 2020 United States Patent Appl. 15459308.
  • 328.Li J, Wang Y, Liu L, Xu S, Liu Y, Leng J, Cai S. A biomimetic soft lens controlled by electrooculographic signal. Adv. Funct. Mater. 2019;29:1903762. doi: 10.1002/adfm.201903762. [DOI] [Google Scholar]
  • 329.Zhang J, et al. Smart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care. Nat. Commun. 2022;13:5518. doi: 10.1038/s41467-022-33254-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 330.Han H H, Kim S-K, Kim S-J, Choi I, Mok J W, Joo C-K, Shin S, Hahn S K. Long-term stable wireless smart contact lens for robust digital diabetes diagnosis. Biomaterials. 2023;302:122315. doi: 10.1016/j.biomaterials.2023.122315. [DOI] [PubMed] [Google Scholar]
  • 331.Li S, et al. A microchambers containing contact lens for the noninvasive detection of tear exosomes. Adv. Funct. Mater. 2022;32:2206620. doi: 10.1002/adfm.202206620. [DOI] [Google Scholar]
  • 332.Zhu H, et al. Frequency-encoded eye tracking smart contact lens for human-machine interaction. Nat. Commun. 2024;15:3588. doi: 10.1038/s41467-024-47851-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 333.Chalupa L M, Werner J S, (Eds.) The Visual Neurosciences 2-vol. Set. The MIT Press; 2003. [Google Scholar]
  • 334.Trenholm S, Krishnaswamy A. An annotated journey through modern visual neuroscience. J. Neurosci. 2020;40:44–53. doi: 10.1523/JNEUROSCI.1061-19.2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 335.Sahel J-A, et al. Partial recovery of visual function in a blind patient after optogenetic therapy. Nat. Med. 2021;27:1223–9. doi: 10.1038/s41591-021-01351-4. [DOI] [PubMed] [Google Scholar]
  • 336.Ponce C R, Xiao W, Schade P F, Hartmann T S, Kreiman G, Livingstone M S. Evolving images for visual neurons using a deep generative network reveals coding principles and neuronal preferences. Cell. 2019;177:999–1009.e10. doi: 10.1016/j.cell.2019.04.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 337.Bahr T, Vu T A, Tuttle J J, Iezzi R. Deep learning and machine learning algorithms for retinal image analysis in neurodegenerative disease: systematic review of datasets and models. Transl. Vis. Sci. Technol. 2024;13:16. doi: 10.1167/tvst.13.2.16. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 338.Teleanu R I, Niculescu A G, Roza E, Vladâcenco O, Grumezescu A M, Teleanu D M. Neurotransmitters—key factors in neurological and neurodegenerative disorders of the central nervous system. Int. J. Mol. Sci. 2022;23:5954. doi: 10.3390/ijms23115954. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 339.Tursini K, Remy I, Le Cam S, Louis-Dorr V, Malka-Mahieu H, Schwan R, Gross G, Laprévote V, Schwitzer T. Subsequent and simultaneous electrophysiological investigation of the retina and the visual cortex in neurodegenerative and psychiatric diseases: what are the forecasts for the medicine of tomorrow? Front. Psychiatry. 2023;14:1167654. doi: 10.3389/fpsyt.2023.1167654. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 340.Sill K. An Eye-Brain Connection. Stanford Medicine; 2021. [Google Scholar]
  • 341.Hensch T K, Quinlan E M. Erratum: PERSPECTIVE Critical periods in amblyopia-CORRIGENDUM (Visual neuroscience (2018) 35 (E014)) Vis. Neurosci. 2018;35:E024. doi: 10.1017/S0952523818000020. [DOI] [PubMed] [Google Scholar]
  • 342.Goetz J, et al. Unified classification of mouse retinal ganglion cells using function, morphology, and gene expression. Cell Rep. 2022;40:111040. doi: 10.1016/j.celrep.2022.111040. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 343.Baden T, Berens P, Franke K, Román Rosón M, Bethge M, Euler T. The functional diversity of retinal ganglion cells in the mouse. Nature. 2016;529:345–50. doi: 10.1038/nature16468. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 344.The MICrONS Consortium Functional connectomics spanning multiple areas of mouse visual cortex. Nature. 2025;640:435–47. doi: 10.1038/s41586-025-08790-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 345.Borda E, Ghezzi D. Advances in visual prostheses: engineering and biological challenges. Prog. Biomed. Eng. 2022;4:032003. doi: 10.1088/2516-1091/ac812c. [DOI] [Google Scholar]
  • 346.Packer A M, Russell L E, Dalgleish H W P, Häusser M. Simultaneous all-optical manipulation and recording of neural circuit activity with cellular resolution in vivo. Nat. Methods. 2015;12:140–6. doi: 10.1038/nmeth.3217. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 347.Carrillo-Reid L, Han S, O’Neil D, Taralova E, Jebara T, Yuste R. Identification of pattern completion neurons in neuronal ensembles using probabilistic graphical models. J. Neurosci. 2021;41:8577–88. doi: 10.1523/JNEUROSCI.0051-21.2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 348.Marshel J H, et al. Cortical layer-specific critical dynamics triggering perception. Science. 2019;365:eaaw5202. doi: 10.1126/science.aaw5202. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 349.González-González M A, et al. Bioelectronic medicine: a multidisciplinary roadmap from biophysics to precision therapies. Front. Integr. Neurosci. 2024;18:1321872. doi: 10.3389/fnint.2024.1321872. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 350.Botto C, Dalkara D, El-Amraoui A. Progress in gene editing tools and their potential for correcting mutations underlying hearing and vision loss. Front. Genome Ed. 2021;3:737632. doi: 10.3389/fgeed.2021.737632. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 351.Hall J C, Paull D, Pébay A, Lidgerwood G E. Human pluripotent stem cells for the modelling of retinal pigment epithelium homeostasis and disease: a review. Clin. Exp. Ophthalmol. 2022;50:667–77. doi: 10.1111/ceo.14128. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 352.Marchesi N, Fahmideh F, Boschi F, Pascale A, Barbieri A. Ocular neurodegenerative diseases: interconnection between retina and cortical areas. Cells. 2021;10:2394. doi: 10.3390/cells10092394. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 353.Keemink S W, Machens C K. Decoding and encoding (de)mixed population responses. Curr. Opin. Neurobiol. 2019;58:112–21. doi: 10.1016/j.conb.2019.09.004. [DOI] [PubMed] [Google Scholar]
  • 354.Rabut C, Yoo S, Hurt R C, Jin Z, Li H, Guo H, Ling B, Shapiro M G. Ultrasound technologies for imaging and modulating neural activity. Neuron. 2020;108:93–110. doi: 10.1016/j.neuron.2020.09.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 355.Ciuffreda K J, Tannen B. Future directions in neuro-optometry. Concussion. 2020;5:CNC80. doi: 10.2217/cnc-2020-0013. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

No new data were created or analysed in this study.


Articles from Journal of Optics (2010) are provided here courtesy of IOP Publishing

RESOURCES