Skip to main content
Physics and Imaging in Radiation Oncology logoLink to Physics and Imaging in Radiation Oncology
. 2025 Nov 22;36:100874. doi: 10.1016/j.phro.2025.100874

Improving reirradiation of recurrent non-small cell lung cancer through non-coplanar beam arrangements☆

Nathan Torelli a,⁎, Jonas Willmann a,b, Katja Dähler a, Madalyne Day a, Nicolaus Andratschke a, Jan Unkelbach a
PMCID: PMC12701979  PMID: 41399698

Graphical abstract

graphic file with name ga1.jpg

Keywords: Reirradiation, Beam orientation optimization, Non-coplanar radiotherapy, Non-small cell lung cancer

Highlights

  • •

    Simultaneous optimization of cumulative dose distribution and non-coplanar arcs.

  • •

    Reirradiation of lung cancer with non-coplanar arcs enhance organ sparing.

  • •

    Maximum cumulative doses reduced by up to 9 Gy for key thoracic organs.

  • •

    ≥5 Gy dose reduction achieved for dose-limiting organs in 40% of patients.

Abstract

Background and purpose

Reirradiation for non-small cell lung cancer (NSCLC) is commonly delivered using coplanar techniques. In this study, we investigated whether the selection of favorable non-coplanar beam orientations may limit cumulative doses to critical organs-at-risk (OARs) and thus improve the therapeutic window.

Materials and methods

Fifteen cases of challenging high-dose reirradiation for locoregionally recurrent NSCLC were included in this in-silico study. For each patient, the dose distribution from the previous treatment was first mapped to the new patient anatomy using rigid dose registration, and subsequently converted to equivalent dose in 2 Gy fractions (EQD2). A two-arc non-coplanar reirradiation plan was then generated using an EQD2-based direct aperture optimization algorithm, which allows for the simultaneous optimization of dynamic gantry-couch paths and the cumulative EQD2 distribution. Non-coplanar reirradiation plans were benchmarked against two-arc coplanar plans.

Results

Considerable reductions of at least 5 Gy in the maximum cumulative EQD2 to critical organs were achieved in 6 out of 15 patients using non-coplanar versus coplanar arcs. In particular, the maximum cumulative EQD2 was reduced by up to −9.0 Gy for the bronchial tree, −5.8 Gy for the esophagus, −5.3 Gy for the trachea and −5.6 Gy for the great vessel. At the same time, target coverage and lung EQD2 metrics were comparable for both methods.

Conclusions

The automated selection of favorable non-coplanar beam orientations may reduce the maximum cumulative EQD2 to critical OARs in challenging thoracic reirradiation cases. This allows to explore either better OAR sparing or dose-escalation in future clinical studies.

1. Introduction

Non-small cell lung cancer (NSCLC) is the most common lung cancer subtype occurring in 85 % of patients and one of the leading causes of cancer death worldwide [1,2]. Despite technological advances and improvements in treatment paradigms, about 16–37% of NSCLC patients will develop locoregional recurrence, with 2- and 5-year survival of 21% and 6%, respectively [[3], [4], [5], [6]]. Reirradiation is the main curative-intent treatment option available for these patients [7]. Retrospective studies suggest that local control and even prolonged survival can be achieved with reirradiation in selected patients [[6], [7], [8], [9], [10]], particularly when using highly conformal treatment techniques and dose fractionation strategies that balance efficacy with safety. However, reirradiation also poses a significant therapeutic challenge due to high cumulative doses which may lead to severe treatment-related toxicities [11].

In this context, it is very important to create reirradiation plans that balance tumor control and the risk of toxicity from cumulative doses. Yet, no commercial treatment planning system currently exists that allows for the optimization of reirradiation plans based on the dose delivered in the previous treatment, while also accounting for normal tissue recovery and dose fractionation. In current clinical practice, reirradiation planning is still mostly based on a manual trial-and-error approach, in which a reirradiation plan is first generated independently of the previous dose distribution, and the cumulative equivalent dose in 2 Gy fractions (EQD2) distribution from all treatments combined is only evaluated a posteriori [12]. The reirradiation plan may then be iteratively adjusted if some clinical goals on the cumulative EQD2 are not met. This approach is not only very time consuming, but may also lead to suboptimal reirradiation plans. Therefore, approaches to facilitate and improve reirradiation planning are warranted [13].

Recently, few groups investigated approaches to improve reirradiation planning by enabling EQD2-based treatment plan optimization. Murray et al. developed a reirradiation planning workflow which allows generating reirradiation plans based on the voxel-by-voxel cumulative EQD2 of the previous treatment and reirradiation plan [14]. They demonstrated that using such an approach, clinically acceptable reirradiation plans could be generated which required less constraint relaxation or allowed for dose escalation. Similarly, Meyer et al. developed a reirradiation planning solution that leverages a combination of dose accumulation scripts to define residual dose constraints for the critical OARs based on cumulative EQD2 isodose line structures, and an automated optimization algorithm [15]. Using such a workflow, they could generate reirradiation plans with superior quality compared to manually generated plans.

Previous studies demonstrated that non-coplanar dynamic trajectories, a technique combining dynamic gantry and couch rotation, enable efficient delivery of non-coplanar radiotherapy treatments using conventional C-arm linear accelerators [[16], [17], [18], [19], [20], [21], [22], [23], [24]]. Building on this concept, our study aimed to extend reirradiation planning research by investigating whether the use of favorable non-coplanar beam orientations can limit dose accumulation to critical OARs. In clinical practice, in fact, coplanar beam arrangements are still most commonly used for both initial and reirradiation treatments [25]. However, when tumors recur close to or overlap with previously irradiated target volumes, such coplanar geometries unavoidably lead to dose accumulation in already exposed tissues. To address this problem, we developed a method to simultaneously optimize non-coplanar dynamic trajectories for the reirradiation plan and the cumulative EQD2 distribution. The proposed approach was evaluated for several challenging high-dose reirradiation cases with locoregional recurrent NSCLC.

2. Materials and methods

2.1. Patients

Fifteen cases of challenging high-dose reirradiation for locoregionally recurrent NSCLC were retrospectively considered in this study (Table S1 in the Supplementary material). All patients were treated for tumor recurrence at our institution between 2016 and 2024 using a coplanar volumetric modulated arc therapy (VMAT) technique. The study was approved by the local ethics committee (BASEC-Nr.: 2018–01794).

2.2. Reirradiation planning workflow

Reirradiation plans were generated using an in-house developed treatment planning workflow, which is schematically illustrated in Fig. 1 and further detailed in the following.

Fig. 1.

Fig. 1

Schematic illustration of the reirradiation planning workflow used in this study. After the dose distribution of the initial radiotherapy has been registered to the reirradiation planning CT and subsequently converted to EQD2, a direct aperture optimization algorithm is used to simultaneously optimize the beam orientations for the reirradiation plan and the cumulative EQD2 distribution. The reirradiation plan delivers non-coplanar arcs, which combine dynamic gantry and couch rotation, aiming to minimize dose accumulation to critical OARs. The dark grey regions in the gantry-couch map represent beam orientations which may lead to collisions between the gantry and the system composed by couch and patient, and are therefore excluded from the search space.

First, the dose distribution from the initial treatment was mapped to the new patient anatomy. In this study, rigid dose registration was used to mimic the approach adopted in our clinic for generating the reirradiation plans for the considered NSCLC patients. However, the same planning workflow may also be used in combination with deformable dose registration. Subsequently, the registered physical dose distribution was converted to EQD2 distribution as follows:

ei(pre)=di(pre)α/βi+di(pre)2α/βi+2 (1)

where ei(pre) and di(pre) are the EQD2 and physical dose in voxel i from the initial treatment(s), respectively, and α/βi is the α/β-ratio of the tissue that voxel i belongs to. Following our institutional guidelines, α/β=2Gy was set for the spinal cord and α/β=3Gy was set for the rest of the body. A non-coplanar reirradiation plan, combining dynamic gantry and couch rotation, was finally generated using a novel EQD2-based direct aperture optimization (DAO) algorithm, which allowed for the simultaneous optimization of the dynamic gantry-couch path and the cumulative EQD2 distribution of both the initial and the reirradiation plans.

2.3. EQD2-based direct aperture optimization algorithm

The proposed DAO algorithm, which was first suggested by Torelli and Unkelbach [26] and extended to the reirradiation setting in this study, combined a column generation based method to iteratively add apertures from promising non-coplanar beam orientations and a gradient-based method to refine the weights and shapes of all apertures along a non-coplanar dynamic arc. Starting from an empty set of control points, the most promising aperture shapes at each candidate beam orientation b∈B were determined by minimizing the sum of partial derivatives of an objective function f (evaluated for the cumulative EQD2) with respect to the fluence of all bixels contained in the aperture:

minimizexL,xR∑l∈Lb∑p=xLlxRl∂f∂νlp (2)

Here, νlp refers to the fluence of the bixel in leaf pair l at position p∈{xLl,⋯,xRl}, xLl and xRl are the left and right positions of the leaf pair l, respectively, and Lb is the set of all MLC leaf pairs that apertures in field b can utilize. Descriptions of strategies to solve the so-called pricing problem in Eq. (2) can be found in the work of Romeijn et al. [27] and Men et al. [28]. The resulting candidate apertures had an associated price, given by the sum of partial derivatives of the objective function f with respect to all bixels not covered by the multileaf collimator (MLC). Since a negative partial derivative indicated that increasing the fluence of the bixel decreased the objective function value, the aperture delivered from the beam orientation with the lowest price was added to the treatment plan at each iteration. In this study, the set of candidate beam orientations B encompassed beam orientations at different pairs of gantry and couch angles, with the gantry angles ranging from −180° to +180° in 5°-steps and the couch angles ranging from −90° to +90° in 2.5°-steps. The treatment isocenter was selected as the center-of-mass of the planning target volume. Beam orientations that may lead to a collision between the gantry and the system composed by couch and patient have been determined for general patient anatomies and treatment isocenters (i.e. they were not patient-specific), and were excluded from the set of candidate beam orientations. After the addition of each new aperture, the search space for candidate beam orientations was updated such that only apertures could be added at beam orientations that could still be efficiently reached by the dynamic gantry-couch path, without the need to slow down the gantry rotation speed. Therefore, the non-coplanar arcs in this study featured similar delivery times as coplanar arcs.

After the addition of each new aperture to the reirradiation plan, the weights of all the already added apertures were optimized and the apertures’ shapes were refined. To this end, the following optimization problem was solved:

minimize(xL,xR),ωf(e∼) (3)
subject toei∼=diα/βi+di2α/βi+2+ei(pre)∀i (4)
di=∑k∈Kωk∑l∈LkΦiklxLkl,xRkl∀i,∀t (5)
ωk≥0∀k (6)
xLk-1l-xLkl≤Δxmax∀k≥1,∀l (7)
xRk-1l-xRkl≤Δxmax∀k≥1,∀l (8)
xLkl≤xRkl∀k,∀l (9)

where ei∼ is the cumulative EQD2 to voxel i, di is the physical dose delivered to voxel i by all MLC-based apertures k∈K in the reirradiation plan, Φikl is the dose contribution of the l-th leaf pair of aperture k to voxel i per unit intensity and ωk is the MU weight of aperture k. The parameters xLkl and xRkl describe the positions of the left and right MLC leaves in the l-th leaf pair of aperture k, respectively, and Lk is the set of all MLC leaf pairs in aperture k. The constraints in Eqs. (7) and (8) were used to limit the MLC displacement between neighboring control points by a maximum distance:

Δxmax=maxvmaxΔθωg,vmaxΔϕωc (10)

where Δθ and Δϕ denote the difference in gantry and couch angles between neighboring control points, vmax is the maximum MLC leaf speed and ωg and ωc are the maximum rotation speed of the gantry and the couch, respectively. In this study, these parameters have been set to vmax=2.5cm/s, ωg=6°/s and ωc=3°/s, respectively, which correspond to the dynamic parameters of a TrueBeam treatment unit equipped with a Millennium MLC 120 (Varian, A Siemens Healtineers Company). This guaranteed an efficient treatment delivery, as described by Peng et al. [29]. The optimization problem in Eqs. (3)–(9) was solved using a gradient-based DAO approach inspired by the work of Cassioli and Unkelbach [30] in combination with our in-house implementation of the L-BFGS quasi-Newton algorithm [31].

2.4. In-silico evaluation of non-coplanar reirradiation plans

For each patient, a two-arc non-coplanar reirradiation plan was generated using the proposed planning workflow. This plan was then benchmarked against a two-arc coplanar reirradiation plan, which mimicked current state-of-the-art practice for reirradiation of NSCLC patients and reflected the technique that was used to treat the considered patients in the clinics. Because of differences in both the dose calculation and plan optimization algorithms used in the commercial and research treatment planning systems, a direct comparison of the non-coplanar reirradiation plan with the clinically delivered reirradiation plan was not meaningfully possible. Therefore, the clinically delivered coplanar reirradiation plan was mimicked in our research treatment planning system by using the same EQD2-based DAO algorithm as for the non-coplanar reirradiation plan, but fixing the beam orientations to B0=θk,ϕk|θk=-180°+k∗5°,ϕk=0°∀k∈{0,1,⋯,72}.

For the purpose of this study, both the coplanar and non-coplanar reirradiation plans were forced to achieve a similar target coverage, in order to quantify the difference in between the two approaches in terms of OAR dose reduction. For each patient, the objective function in Eq. (3) was defined through a weighted sum of dose-volume, mean dose and dose conformity objectives (as reported in the Supplementary material A). To guarantee that the prescribed dose was delivered to the tumor in the reirradiation plan and that the reirradiation plan was conformal, the under- and over-dose planning objectives for the PTV, as well as the normal tissue objective, were evaluated only for the EQD2 distribution resulting from the reirradiation plan, and not for the cumulative EQD2. The comparison between the coplanar and non-colpanar reirradiation plans was performed by evaluating target coverage, dose conformity and cumulative EQD2 metrics to the OARs (without considering any overlap with the PTV).

3. Results

The greatest reduction of OAR doses between the coplanar and non-coplanar reirradiation plans was observed for patient 4, who had a tumor recurrence very close (but without overlap) to a few OARs that already received a large dose in the initial treatment (Fig. 2). In this situation, the use of coplanar VMAT arcs unavoidably deposited additional radiation dose to OAR regions that already received a very large dose in the initial radiotherapy. Consequently, the coplanar reirradiation plan achieved very high maximum EQD2 of 141.3 Gy in the bronchial tree, 95.9 Gy in the esophagus, 120.6 Gy in the great vessel and 127.6 Gy in the trachea, which exceeded the maximum tolerated EQD2 constraints (Table 1). By using optimized non-coplanar beam orientations, on the other hand, the non-coplanar reirradiation plan could better direct the integral dose to regions of the body which previously did not receive any dose or only limited dose from the initial radiotherapy, while also achieving a much steeper dose gradient outside of the target. Compared to the coplanar reirradiation plan, the non-coplanar reirradiation plan reduced the maximum cumulative EQD2 to bronchial tree, esophagus, great vessel and trachea by 9.0 Gy (−6.4%), 5.0 Gy (−5.2%), 5.6 Gy (−4.6%) and 4.9 Gy (−3.8%), respectively, for a similar target coverage (CI: 0.75 vs 0.75).

Fig. 2.

Fig. 2

Comparison of the coplanar and non-coplanar reirradiation plans generated for patient 4. Contours of PTV (red), bronchial tree (green), esophagus (brown) and great vessel (blue) are delineated in both the transversal and coronal planes of the reirradiation scan. The gantry-couch paths for both reirradiation plans are also shown, where dark grey regions indicate beam orientations leading to collision between gantry and couch (and are therefore excluded from the set of candidate beam orientations). (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Table 1.

Cumulative EQD2 metrics that exceeded the recommended EQD2 constraints (according to our institutional clinical protocol for thoracic reirradiation), both prior to reirradiation and after reirradiation using the coplanar and non-coplanar plans. The cumulative EQD2 metrics for all patients and OARs (including the ones respecting the constraints) are reported in the Supplementary material B. Percentage differences in EQD2 values between the coplanar and non-coplanar reirradiation plans are reported for each parameter.

OAR Recommended EQD2 constraint Previous treatment(s) (Gy) Coplanar reirradiation plan (Gy) Non-coplanar reirradiation plan (Gy)
Patient 1 Bronchial tree Dmax < 120 Gy 71.4 124.0 122.5 (−1.2%)
Esophagus Dmax < 90 Gy 126.9 126.9 126.9 (=)
Trachea Dmax < 110 Gy 117.2 117.2 117.2 (=)
Patient 3 Esophagus Dmax < 90 Gy 98.8 100.6 99.7 (−0.9%)
Patient 4 Bronchial tree Dmax < 120 Gy 120 141.3 132.3 (−6.4%)
Esophagus Dmax < 90 Gy 86.3 95.9 90.9 (−5.2%)
Great vessel Dmax < 120 Gy 114.9 120.6 115.0 (−4.6%)
Trachea Dmax < 110 Gy 117.5 127.6 122.7 (−3.8%)
Patient 6 Bronchial tree Dmax < 120 Gy 131.3 142.4 142.7 (=)
Esophagus Dmax < 90 Gy 92.4 99.5 95.8 (−3.7%)
Heart Dmax < 85 Gy 144.7 159.2 157.4 (−1.1%)
Great vessel Dmax < 120 Gy 143.5 159.6 158.5 (−0.7%)
Patient 8 Thoracic wall Dmax < 120 Gy 237.8 270.9 270.3 (−0.2%)
Patient 10 Bronchial tree Dmax < 120 Gy 70.4 121.2 121.2 (=)
Thoracic wall Dmax < 120 Gy 173.9 173.9 173.9 (=)
Trachea Dmax < 110 Gy 71.3 115.1 111.4 (−3.2%)
Patient 13 Bronchial tree Dmax < 120 Gy 127.4 129.2 129.0 (=)
Patient 15 Heart Dmax < 85 Gy 60.6 89.4 89.1 (=)

In 6 out of 15 patients (40%), the non-coplanar reirradiation plan could reduce the maximum cumulative EQD2 to at least one critical OAR by at least 5 Gy compared to the coplanar reirradiation plan (Fig. 3). In particular, large reductions in the maximum cumulative EQD2 were achieved for bronchial tree (up to −9.0 Gy), esophagus (up to −5.8 Gy), heart (up to −6.4 Gy), thoracic wall (up to −7.5 Gy), trachea (up to −5.3 Gy), great vessel (up to −5.6 Gy) and brachial plexus (up to −9.4 Gy). At the same time, the mean lung EQD2 was reduced on average by 0.2 ± 0.1 Gy ([−0.5 Gy, −0.1 Gy]), lung V5Gy was reduced on average by 0.6±1.0% ([−3.5%, +0.3%]) and lung V20Gy was reduced on average by 0.7±0.7% ([−2.7%, −0.1%]) using optimized non-coplanar versus coplanar arcs (more detailed dosimetric results for each individual patientare reported in the Supplementary material B).

Fig. 3.

Fig. 3

Comparison of the most relevant plan parameters between the coplanar and non-coplanar reirradiation plans for all considered patients (boxplots report median values along with 25% and 75% percentiles). The conformity index in the PTV is given by CI=VPTV∩Vdpres2VPTVVdpres (where VPTV is the PTV volume and Vdpres is the total volume receiving the prescribed cumulative dose dpres), while the homogeneity index is expressed as HI=d2-d98dpres (where d2 and d98 are the doses received by 2% and 98% of the PTV volume in the reirradiation plan, respectively).

Reduction of the cumulative EQD2 to critical OARs required less constraint relaxation. For 8 out of 15 of the considered patients (53%), in fact, the coplanar reirradiation plans exceeded the cumulative EQD2 constraints for at least one critical OAR (Table 1). While in most of the cases the OAR constraints were already exceeded by the initial radiotherapy alone (mainly due to overlaps between the previous target volume and critical OARs), in 6 out of 18 OAR constraint violations (33%) this was due to the additional dose contribution from the coplanar reirradiation plan. By using optimized non-coplanar arcs, the non-coplanar reirradiation plans could better spare some of these OARs. In particular, the maximum EQD2 to the great vessel in patient 4 could be kept below the recommended EQD2 constraint of 120 Gy with the non-coplanar reirradiation plan. Similarly, the maximum EQD2 to the bronchial tree in patient 1, to the esophagus in patient 4 and to the trachea in patient 10 could be kept within +2% from the corresponding constraints.

4. Discussion

In this study, an EQD2-based beam orientation optimization algorithm for reirradiation planning was developed and demonstrated for several cases of challenging high-dose reirradiation for locoregionally recurrent NSCLC. By selecting appropriate non-coplanar dynamic trajectories to be delivered in the reirradiation plan, it was shown that the integral dose could be directed to regions of the body that did not receive any dose or only a little dose in the initial radiotherapy, thus considerably reducing the maximum cumulative EQD2 to critical thoracic OARs compared to reirradiation plans that were delivered using coplanar VMAT arcs. This may limit treatment-related toxicities or allow for tumor dose escalation.

This study examined two concepts which are currently not released in commercial treatment planning systems: plan optimization based on cumulative EQD2 constraints and treatment delivery using non-coplanar dynamic trajectories. Murray et al. [14] and Meyer et al. [15] already showed that EQD2-based treatment plan optimization is an efficient and effective approach for generating reirradiation plans, which can improve on manual trial-and-error planning methods. However, while a lot of research is currently focused on making EQD2-based reirradiation planning available on commercial treatment planning systems [13], in this study it was demonstrated that EQD2-based treatment plan optimization alone may not always suffice to create clinically acceptable reirradiation plans, especially for challenging high-dose reirradiation patients. Approaches to improve reirradiation plans by further limiting the cumulative OAR exposure, such as the use of non-coplanar beam orientations presented in this study or the use of proton therapy [32,33], are indeed equally important to facilitate reirradiation by potentially reducing the risk of treatment-related toxicities and allowing for dose escalation to the target. The delivery of non-coplanar dynamic trajectories was also previously investigated by several authors [[17], [18], [19], [20], [21], [22], [23], [24], [25], [26]]. Previous studies demonstrated for several treatment sites that non-coplanar arcs combining dynamic gantry and couch rotation could considerably reduce the dose to OARs, while maintaining a similar delivery efficiency as coplanar VMAT arcs. In most studies, however, the selection of favorable non-coplanar beam orientations was mainly dictated by geometrical reasons (i.e. to avoid delivering dose directly through critical OARs). Per contra, the beam selection strategy used in this study aimed to spare regions of the body which already received a large dose in the initial treatment and was thus less influenced by the patient geometry (similar to the approach adopted by Bedford et al. [34], who considered lung function).

The reirradiation planning framework proposed in this work was implemented within our in-house research treatment planning system and thus no direct clinical implementation is possible yet. In addition, although the simultaneous rotation of gantry and couch is supported by most commercial C-arm linear accelerators, the clinical implementation of non-coplanar dynamic arcs still faces some potential problems, like the increased risk of collision between the gantry head and the system composed by couch and patient, and intra-fraction patient motion due to the continuous couch rotation. To address these challenges, Islam et al. [35] and Guyer et al. [36] developed accurate collision prediction models to assess the deliverability of given arc configurations. Mackeprang et al. [37], instead, demonstrated that dynamic table movement can be well tolerated by patients. Alternative approaches for the generation and delivery of non-coplanar reirradiation plans which present less hurdles for a clinical implementation may nevertheless be considered. For example, dose prediction algorithms could be used in combination with dose accumulation scripts to determine fixed couch kicks for which a non-coplanar VMAT reirradiation plan is expected to minimize the cumulative EQD2 exposure of the most critical OARs. Alternatively, coplanar VMAT arcs may also be combined with few non-coplanar beams as previously shown by Sharfo et al. [38,39].

Although further research must be conducted to identify patient characteristics (e.g. size and location of the tumor with respect to the most critical OARs in the initial and reirradiation treatments) and treatment sites which benefit the most from the use of optimized non-coplanar beam orientations, the results of this study provide quantitative evidence that the patient-specific selection of non-coplanar beam configurations can substantially reduce the cumulative dose burden in the normal tissue associated with reirradiation of patients with locoregionally recurrent NSCLC.

CRediT authorship contribution statement

Nathan Torelli: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Validation, Visualization, Writing – original draft. Jonas Willmann: Conceptualization, Data curation, Investigation, Validation, Visualization, Supervision, Writing – review & editing. Katja Dähler: Data curation, Writing – review & editing. Madalyne Day: Investigation, Methodology, Writing – review & editing. Nicolaus Andratschke: Project administration, Supervision, Writing – review & editing. Jan Unkelbach: Conceptualization, Formal analysis, Investigation, Methodology, Funding acquisition, Project administration, Resources, Supervision, Writing – review & editing.

Declaration of competing interest

The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: The University Hospital of Zurich has a research agreement with Varian Medical Systems, a Siemens Healthineers company. The University Hospital of Zurich has previously received research funding from Viewray Inc.

Footnotes

☆

This article is part of a special issue entitled: ‘Reirradiation’ published in Physics and Imaging in Radiation Oncology.

Supplementary data to this article can be found online at https://doi.org/10.1016/j.phro.2025.100874.

Supplementary data

The following are the Supplementary data to this article:

Supplementary Data 1
mmc1.docx (5.9MB, docx)

References

  • 1.Siegel R.L., Miller K.D., Fuchs H.E., Jemal A. Cancer statistics, 2022. CA Cancer J Clin. 2022;72:7–33. doi: 10.3322/caac.21708. [DOI] [PubMed] [Google Scholar]
  • 2.Molina J.R., Yang P., Cassivi S.D., Schild S.E., Adjei A.A. Non-small cell lung cancer: epidemiology, risk factors, treatment, and survivorship. Mayo Clin Proc. 2008;83:584–594. doi: 10.4065/83.5.584. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.van den Berg L.L., Klinkenberg T.J., Groen H.J.M., Widder J. Patterns of recurrence and survival after surgery or stereotactic radiotherapy for early stage NSCLC. J Thorac Oncol. 2015;10:826–831. doi: 10.1097/JTO.0000000000000483. [DOI] [PubMed] [Google Scholar]
  • 4.Isaka M., Kojima H., Takahashi S., Omae K., Ohde Y. Risk factors for local recurrence after lobectomy and lymph node dissection in patients with non-small cell lung cancer: implications for adjuvant therapy. Lung Cancer. 2018;115:28–33. doi: 10.1016/j.lungcan.2017.11.014. [DOI] [PubMed] [Google Scholar]
  • 5.Taylor M.D., Nagji A.S., Bhamidipati C.M., Theodosakis N., Kozower B.D., Lau C.L., et al. Tumor recurrence after complete resection for non-small cell lung cancer. Ann Thorac Surg. 2012;93:1813–1821. doi: 10.1016/j.athoracsur.2012.03.031. [DOI] [PubMed] [Google Scholar]
  • 6.Nicosia L., Di Muzio J., Agolli L., Alongi F., Mazzola R., Valeriani M., et al. What is the role of reirradiation in the management of locoregionally relapsed non small-cell lung cancer? Lung Cancer. 2020;146:263–275. doi: 10.1016/j.lungcan.2020.06.017. [DOI] [PubMed] [Google Scholar]
  • 7.Hunter B., Crockett C., Faivre-Finn C., Hiley C., Salem A. Re-irradiation of recurrent non-small cell lung cancer. Semin Radiat Oncol. 2021;31:124–132. doi: 10.1016/j.semradonc.2020.11.009. [DOI] [PubMed] [Google Scholar]
  • 8.Vyfhuis M.A.L., Rice S., Remick J., Mossahebi S., Badiyan S., Mohindra P., et al. Reirradiation for locoregionally recurrent non-small cell lung cancer. J Thorac Dis. 2018;10:2522–2536. doi: 10.21037/jtd.2017.12.50. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.De Ruysscher D., Faivre-Finn C., Le Pechoux C., Peeters S., Belderbos J. High-dose re-irradiation following radical radiotherapy for non-small-cell lung cancer. LancetOncol. 2014;15:e620–e624. doi: 10.1016/S1470-2045(14)70345-6. [DOI] [PubMed] [Google Scholar]
  • 10.Ross D., Chan D., Kuo E., Harkenrider M. Thoracic reirradiation with Stereotactic Body Radiation Therapy (SBRT) for recurrent advanced Non-Small Cell Lung Cancer (NSCLC) Pract Radiat Oncol. 2024;14:234–240. doi: 10.1016/j.prro.2024.02.001. [DOI] [PubMed] [Google Scholar]
  • 11.Schröder C., Stiefel I., Tanadini-Lang S., Pytko I., Vu E., Guckenberger M., et al. Re-irradiation in the thorax – an analysis of efficacy and safety based on accumulated EQD2 doses. Radiother Oncol. 2020;152:56–62. doi: 10.1016/j.radonc.2020.07.033. [DOI] [PubMed] [Google Scholar]
  • 12.Ayadi M., Dupuis P., Baudier T., Padovani L., Sarrut D., Sunyach M.P. Management of reirradiations: a clinical and technical overview based on a French survey. Phys Med. 2023;109 doi: 10.1016/j.ejmp.2023.102582. [DOI] [PubMed] [Google Scholar]
  • 13.Vasquez Osorio E., Mayo C., Jackson A., Appelt A. Challenges of re-irradiation: a call to arms for physicists – and radiotherapy vendors. Radiother Oncol. 2023;182 doi: 10.1016/j.radonc.2023.109585. [DOI] [PubMed] [Google Scholar]
  • 14.Murray L., Thompson C., Pagett C., Lilley J., Al-Qaisieh B., Svensson S., et al. Treatment plan optimisation for reirradiation. Radiother Oncol. 2023;182 doi: 10.1016/j.radonc.2023.109545. [DOI] [PubMed] [Google Scholar]
  • 15.Meyer S., Zhang L., Liu Y., Kuo L.C., Hu Y.C., Yamada Y., et al. Automated planning of stereotactic spine re-irradiation using cumulative dose limits. Phys Imaging Radiat Oncol. 2024;29 doi: 10.1016/j.phro.2024.100547. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Liang J., Atwood T., von Eyben R., Fahimian B., Chin E., Horst K., et al. Trajectory modulated arc therapy: a fully dynamic delivery with synchronized couch and gantry motion significantly improves dosimetric indices correlated with poor cosmesis in accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys. 2015;92:1148–1156. doi: 10.1016/j.ijrobp.2015.04.034. [DOI] [PubMed] [Google Scholar]
  • 17.Krayenbuehl J., Davis J.B., Ciernik I.F. Dynamic intensity-modulated non-coplanar arc radiotherapy (INCA) for head and neck cancer. Radiother Oncol. 2006;81:151–157. doi: 10.1016/j.radonc.2006.09.004. [DOI] [PubMed] [Google Scholar]
  • 18.Papp D., Bortfeld T., Unkelbach J. A modular approach to intensity-modulated arc therapy optimization with noncoplanar trajectories. Phys Med Biol. 2015;60:5179–5198. doi: 10.1088/0031-9155/60/13/5179. [DOI] [PubMed] [Google Scholar]
  • 19.Smyth G., Bamber J.C., Evans P.M., Bedford J.L. Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy. Phys Med Biol. 2013;58:8163–8177. doi: 10.1088/0031-9155/58/22/8163. [DOI] [PubMed] [Google Scholar]
  • 20.Smyth G., Evans P.M., Bamber J.C., Mandeville H.C., Welsh L.C., Saran F.H., et al. Non-coplanar trajectories to improve organ at risk sparing in volumetric modulated arc therapy for primary brain tumors. Radiother Oncol. 2016;121:124–131. doi: 10.1016/j.radonc.2016.07.014. [DOI] [PubMed] [Google Scholar]
  • 21.Wild E., Bangert M., Nill S., Oelfke U. Noncoplanar VMAT for nasopharyngeal tumors: plan quality versus treatment time. Med Phys. 2015;42:2157–2168. doi: 10.1118/1.4914863. [DOI] [PubMed] [Google Scholar]
  • 22.Popescu C.C., Beckham W.A., Patenaude V.V., Olivotto I.A., Vlachaki M.T. Simultaneous couch and gantry dynamic arc rotation (CG-Darc) in the treatment of breast cancer with accelerated partial breast irradiation (APBI): a feasibility study. J Appl Clin Med Phys. 2013;14:4035. doi: 10.1120/jacmp.v14i1.4035. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Fix M.K., Frei D., Volken W., Terribilini D., Mueller S., Elicin O., et al. Part 1: Optimization and evaluation of dynamic trajectory radiotherapy. Med Phys. 2018 doi: 10.1002/mp.13086. Published online July 10. [DOI] [PubMed] [Google Scholar]
  • 24.Mullins J., Renaud M.A., Serban M., Seuntjens J. Simultaneous trajectory generation and volumetric modulated arc therapy optimization. Med Phys. 2020;47:3078–3090. doi: 10.1002/mp.14155. [DOI] [PubMed] [Google Scholar]
  • 25.Rulach R., Ball D., Chua K.L.M., Dahele M., De Ruysscher D., Franks K., et al. An international expert survey on the indications and practice of radical thoracic reirradiation for non-small cell lung cancer. Adv Radiat Oncol. 2021;6 doi: 10.1016/j.adro.2021.100653. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Torelli N., Unkelbach J. Fraction-variant beam orientation optimization for spatiotemporal fractionation schemes. Med Phys. 2025;52:4723–4741. doi: 10.1002/mp.17798. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Romeijn H.E., Ahuja R.K., Dempsey J.F., Kumar A. A column generation approach to radiation therapy treatment planning using aperture modulation. SIAM J Optim. 2005;15:838–862. doi: 10.1137/040606612. [DOI] [Google Scholar]
  • 28.Men C., Gu X., Choi D., Majumdar A., Zheng Z., Mueller K., et al. GPU-based ultrafast IMRT plan optimization. Phys Med Biol. 2009;54:6565–6573. doi: 10.1088/0031-9155/54/21/008. [DOI] [PubMed] [Google Scholar]
  • 29.Peng F., Jia X., Gu X., Epelman M.A., Romeijn H.E., Jiang S.B. A new column-generation-based algorithm for VMAT treatment plan optimization. Phys Med Biol. 2012;57:4569–4588. doi: 10.1088/0031-9155/57/14/4569. [DOI] [PubMed] [Google Scholar]
  • 30.Cassioli A., Unkelbach J. Aperture shape optimization for IMRT treatment planning. Phys Med Biol. 2013;58:301–318. doi: 10.1088/0031-9155/58/2/301. [DOI] [PubMed] [Google Scholar]
  • 31.Wright S.J., Nocedal J. vol 2. Springer; 1999. (Numerical Optimization). [Google Scholar]
  • 32.Chao H.H., Berman A.T. Proton therapy for thoracic reirradiation of non-small cell lung cancer. Transl Lung Cancer Res. 2018;7:153–159. doi: 10.21037/tlcr.2018.03.22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Troost E.G.C., Wink K.C.J., Roelofs E., Simone C.B., Makocki S., Löck S., et al. Photons or protons for reirradiation in (non-)small cell lung cancer: results of the multicentric ROCOCO in silico study. Br J Radiol. 2020;93 doi: 10.1259/bjr.20190879. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Bedford J.L., Ahmed M. Functional lung avoidance in radiotherapy using optimisation of biologically effective dose with non-coplanar beam orientations. Phys Imaging Radiat Oncol. 2023;28 doi: 10.1016/j.phro.2023.100518. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Islam N., Kilian-Meneghin J., deBoer S., Podgorsak M. A collision prediction framework for noncoplanar radiotherapy planning and delivery. J Appl Clin Med Phys. 2020;21:92–106. doi: 10.1002/acm2.12920. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Guyer G., Mueller S., Wyss Y., Bertholet J., Schmid R., Stampanoni M.F.M., et al. Technical note: a collision prediction tool using Blender. J Appl Clin Med Phys. 2023;24 doi: 10.1002/acm2.14165. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Mackeprang P.H., Bertholet J., Wessels C., Rossel J.B., Limacher A., Aebersold D.M., et al. A randomized safety study of tolerance to table rotation in dynamic trajectory radiotherapy in healthy volunteers. Phys Imaging Radiat Oncol. 2025;35 doi: 10.1016/j.phro.2025.100796. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Sharfo A.W.M., Rossi L., Dirkx M.L.P., Breedveld S., Aluwini S., Heijmen B.J.M. Complementing prostate SBRT VMAT with a two-beam non-coplanar IMRT class solution to enhance rectum and bladder sparing with minimum increase in treatment time. Front Oncol. 2021;11 doi: 10.3389/fonc.2021.620978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Sharfo A.W., Dirkx M.L., Breedveld S., Méndez Romero A., Heijmen B.J. VMAT plus a few computer-optimized non-coplanar IMRT beams (VMAT+) tested for liver SBRT. Radiother Oncol. 2017;123:49–56. doi: 10.1016/j.radonc.2017.02.018. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Data 1
mmc1.docx (5.9MB, docx)

Articles from Physics and Imaging in Radiation Oncology are provided here courtesy of Elsevier

RESOURCES