Abstract
Arrival-time analysis was applied to intravenous digital aortograms. A single static image was produced by representing the time to 90% maximum density for each image pixel on a grey scale. Arrival-time analysis confirmed the diagnosis in four of six patients with aortic dissection that had been shown by image subtraction. In a further three patients with no dissection the arrival-time images were normal. In two patients with surgical repair of the ascending aorta, residual false lumens were shown by both subtraction and arrival-time analysis. In one of these cases arrival-time analysis prompted reanalysis of the subtraction image that had previously been interpreted as showing a normal aorta. Arrival-time analysis provides a static image of aortic dissection, which helps to overcome subtraction artefact.
Full text
PDF




Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Grossman L. B., Buonocore E., Modic M. T., Meaney T. F. Digital subtraction angiography of the thoracic aorta. Radiology. 1984 Feb;150(2):323–325. doi: 10.1148/radiology.150.2.6361849. [DOI] [PubMed] [Google Scholar]
- Hunter G. J., Hunter J. V., Brown N. J. Parametric imaging using digital subtraction angiography. Br J Radiol. 1986 Jan;59(697):7–11. doi: 10.1259/0007-1285-59-697-7. [DOI] [PubMed] [Google Scholar]