Abstract
A new pulsed Doppler mapping technique has been used to measure the severity of aortic valve stenosis. The Doppler examination was performed at the site of the aortic orifice in the parasternal short axis echocardiographic view and the method was based on the detection of the area of systolic flow through the stenotic orifice. This area was derived by planimetry and the measurements obtained by the Doppler method were compared with the aortic valve area calculated at catheterisation according to the Gorlin formula. The method was applicable in 41 of the 44 patients studied. The Doppler data were consistent with the haemodynamic measurements even in patients with decreased cardiac index. It is concluded that this new application of the flow mapping procedure is reliable and is easily applied to adult patients with a wide range of clinical conditions.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- BENCHIMOL A., DIMOND E. G., SHEN Y. Ejection time in aortic stenosis and mitral stenosis. Comparison between the direct and indirect arterial tracings with special reference to preand postoperative findings. Am J Cardiol. 1960 Jun;5:728–743. doi: 10.1016/0002-9149(60)90049-7. [DOI] [PubMed] [Google Scholar]
- Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
- Carrillo Kabana J., Calderón Montero J., López Sendón J., Fuertes Garcia A., Pey Illera J. Valoración cuantitativa y cualitativa de las insuficiencias mitral y aórtica. Estudio comparativo. Rev Esp Cardiol. 1976 May-Jun;29(3):227–235. [PubMed] [Google Scholar]
- DeMaria A. N., Bommer W., Joye J., Lee G., Bouteller J., Mason D. T. Value and limitations of cross-sectional echocardiography of the aortic valve in the diagnosis and quantification of valvular aortic stenosis. Circulation. 1980 Aug;62(2):304–312. doi: 10.1161/01.cir.62.2.304. [DOI] [PubMed] [Google Scholar]
- GORLIN R., GORLIN S. G. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. Am Heart J. 1951 Jan;41(1):1–29. doi: 10.1016/0002-8703(51)90002-6. [DOI] [PubMed] [Google Scholar]
- Goldberg S. J., Sahn D. J., Allen H. D., Valdes-Cruz L. M., Hoenecke H., Carnahan Y. Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis. Am J Cardiol. 1982 Dec;50(6):1394–1400. doi: 10.1016/0002-9149(82)90481-7. [DOI] [PubMed] [Google Scholar]
- Griffith J. M., Henry W. L. An ultrasound system for combined cardiac imaging and Doppler blood flow measurement in man. Circulation. 1978 May;57(5):925–930. doi: 10.1161/01.cir.57.5.925. [DOI] [PubMed] [Google Scholar]
- Hatle L., Angelsen B. A., Tromsdal A. Non-invasive assessment of aortic stenosis by Doppler ultrasound. Br Heart J. 1980 Mar;43(3):284–292. doi: 10.1136/hrt.43.3.284. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hoffmann A., Burckhardt D. Evaluation of systolic murmurs by Doppler ultrasonography. Br Heart J. 1983 Oct;50(4):337–342. doi: 10.1136/hrt.50.4.337. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Johnson S. L., Baker D. W., Lute R. A., Dodge H. T. Doppler echocardiography. The localization of cardiac murmurs. Circulation. 1973 Oct;48(4):810–822. doi: 10.1161/01.cir.48.4.810. [DOI] [PubMed] [Google Scholar]
- Jorgensen J. E., Campau D. N., Baker D. W. Physical characteristics and mathematical modelling of the pulsed ultrasonic flowmeter. Med Biol Eng. 1973 Jul;11(4):404–421. doi: 10.1007/BF02483686. [DOI] [PubMed] [Google Scholar]
- Kosturakis D., Allen H. D., Goldberg S. J., Sahn D. J., Valdes-Cruz L. M. Noninvasive quantification of stenotic semilunar valve areas by Doppler echocardiography. J Am Coll Cardiol. 1984 May;3(5):1256–1262. doi: 10.1016/s0735-1097(84)80185-0. [DOI] [PubMed] [Google Scholar]
- Macpherson P. C., Meldrum S. J., Tunstall-Pedoe D. S. Angioscan: a spectrum analyser for use with ultrasonic Doppler velocimeters. J Med Eng Technol. 1981 Mar;5(2):84–85. doi: 10.3109/03091908109042444. [DOI] [PubMed] [Google Scholar]
- Miyatake K., Okamoto M., Kinoshita N., Ohta M., Kozuka T., Sakakibara H., Nimura Y. Evaluation of tricuspid regurgitation by pulsed Doppler and two-dimensional echocardiography. Circulation. 1982 Oct;66(4):777–784. doi: 10.1161/01.cir.66.4.777. [DOI] [PubMed] [Google Scholar]
- Stamm R. B., Martin R. P. Quantification of pressure gradients across stenotic valves by Doppler ultrasound. J Am Coll Cardiol. 1983 Oct;2(4):707–718. doi: 10.1016/s0735-1097(83)80311-8. [DOI] [PubMed] [Google Scholar]
- Veyrat C., Abitbol G., Bas S., Manin J. P., Kalmanson D. Quantitative assessment of valvular regurgitations using the pulsed Doppler technique. Approach to the regurgitant lesion. Ultrasound Med Biol. 1984 Mar-Apr;10(2):201–213. doi: 10.1016/0301-5629(84)90219-9. [DOI] [PubMed] [Google Scholar]
- Warth D. C., Stewart W. J., Block P. C., Weyman A. E. A new method to calculate aortic valve area without left heart catheterization. Circulation. 1984 Dec;70(6):978–983. doi: 10.1161/01.cir.70.6.978. [DOI] [PubMed] [Google Scholar]