Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1987 Oct;58(4):369–373. doi: 10.1136/hrt.58.4.369

Balloon dilatation of unoperated aortic coarctation: immediate results and one year follow up.

C Wren 1, I Peart 1, H Bain 1, S Hunter 1
PMCID: PMC1277269  PMID: 3676023

Abstract

Fifteen patients aged 1-19 years (mean 10.9) with previously unoperated aortic coarctation underwent percutaneous balloon angioplasty between January 1985 and February 1986. Nine (60%) were hypertensive at presentation. Under general anaesthetic the systolic coarctation gradient was 24-50 mm Hg (mean 29) and the coarctation diameter was 4-9 mm (mean 5.5). Meditech balloon catheters 8-18 mm in diameter were inflated 1-4 times at 410-760 kPa. After dilatation the systolic coarctation gradient decreased to 0-20 mm Hg (mean 6) and the coarctation diameter increased to 7-20 mm (mean 12). One patient developed a fusiform aneurysm of the aorta at the coarctation site immediately after the procedure. At reinvestigation 6-16 months (mean 12.5) after dilatation 14 of the 15 patients were normotensive. In 13 patients the residual coarctation gradient was 0-10 mm Hg (mean 3). Two patients had recoarctation with residual gradients of 20 and 24 mm Hg and underwent successful repeat dilatation. One patient had developed a small discrete aneurysm at the coarctation site. Balloon angioplasty is thus a safe and effective method of relieving unoperated aortic coarctation. The frequency of aortic aneurysm and recoarctation is small and probably related to balloon size. This early experience is encouraging, but long term results and further experience are required before this approach is used to treat coarctation generally.

Full text

PDF

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ala-Kulju K., Järvinen A., Maamies T., Mattila S., Merikallio E. Late aneurysms after patch aortoplasty for coarctation of the aorta in adults. Thorac Cardiovasc Surg. 1983 Oct;31(5):301–306. doi: 10.1055/s-2007-1022001. [DOI] [PubMed] [Google Scholar]
  2. Bull C. Interventional catheterisation in infants and children. Br Heart J. 1986 Sep;56(3):197–200. doi: 10.1136/hrt.56.3.197. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Carpenter M. A., Dammann J. F., Watson D. D., Jedeikin R., Tompkins D. G., Beller G. A. Left ventricular hyperkinesia at rest and during exercise in normotensive patients 2 to 27 years after coarctation repair. J Am Coll Cardiol. 1985 Oct;6(4):879–886. doi: 10.1016/s0735-1097(85)80498-8. [DOI] [PubMed] [Google Scholar]
  4. Cooper R. S., Ritter S. B., Rothe W. B., Chen C. K., Griepp R., Golinko R. J. Angioplasty for coarctation of the aorta: long-term results. Circulation. 1987 Mar;75(3):600–604. doi: 10.1161/01.cir.75.3.600. [DOI] [PubMed] [Google Scholar]
  5. Finley J. P., Beaulieu R. G., Nanton M. A., Roy D. L. Balloon catheter dilatation of coarctation of the aorta in young infants. Br Heart J. 1983 Nov;50(5):411–415. doi: 10.1136/hrt.50.5.411. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Hehrlein F. W., Mulch J., Rautenburg H. W., Schlepper M., Scheld H. H. Incidence and pathogenesis of late aneurysms after patch graft aortoplasty for coarctation. J Thorac Cardiovasc Surg. 1986 Aug;92(2):226–230. [PubMed] [Google Scholar]
  7. Lababidi Z. A., Daskalopoulos D. A., Stoeckle H., Jr Transluminal balloon coarctation angioplasty: experience with 27 patients. Am J Cardiol. 1984 Dec 1;54(10):1288–1291. doi: 10.1016/s0002-9149(84)80083-1. [DOI] [PubMed] [Google Scholar]
  8. Lock J. E., Bass J. L., Amplatz K., Fuhrman B. P., Castaneda-Zuniga W. Balloon dilation angioplasty of aortic coarctations in infants and children. Circulation. 1983 Jul;68(1):109–116. doi: 10.1161/01.cir.68.1.109. [DOI] [PubMed] [Google Scholar]
  9. Lock J. E., Castaneda-Zuniga W. R., Bass J. L., Foker J. E., Amplatz K., Anderson R. W. Balloon dilatation of excised aortic coarctations. Radiology. 1982 Jun;143(3):689–691. doi: 10.1148/radiology.143.3.6210934. [DOI] [PubMed] [Google Scholar]
  10. Lock J. E., Keane J. F., Fellows K. E. The use of catheter intervention procedures for congenital heart disease. J Am Coll Cardiol. 1986 Jun;7(6):1420–1423. doi: 10.1016/s0735-1097(86)80166-8. [DOI] [PubMed] [Google Scholar]
  11. Lock J. E., Niemi T., Burke B. A., Einzig S., Castaneda-Zuniga W. R. Transcutaneous angioplasty of experimental aortic coarctation. Circulation. 1982 Dec;66(6):1280–1286. doi: 10.1161/01.cir.66.6.1280. [DOI] [PubMed] [Google Scholar]
  12. Lock J. E. Now that we can dilate, should we? Am J Cardiol. 1984 Dec 1;54(10):1360–1360. doi: 10.1016/s0002-9149(84)80098-3. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES