Abstract
Paclitaxel (Pac) is an important anticancer bioactive compound, and the availability of an accurate and robust analytical method for its quantification is of utmost importance. In this investigation, a novel, direct, and reliable spectrophotometric method has been proposed for the estimation of Pac via a complex formation reaction with osmium (Os). The method was based on the reaction of Pac with Os tetroxide, which produced a yellowish-brown complex. The resulting complex is soluble in water and displays a maximum absorption peak at 482 nm. The reaction conditions, including reactant concentration, pH, temperature, and reaction time, were optimized to obtain the best spectrophotometric response. A thorough method validation study was conducted, demonstrating that the calibration curve is linear over the concentration range of 1.0–55 μg/mL and follows Beer’s law, with a molar absorptivity of 3.01 × 10−4 L/mol−1.cm−1. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.0098 and 0.0328 μg/mL, respectively. The recovery values were planned and found to be 98.70%–100.23%. At the same time, the precision values (represented by relative standard deviation percent [RSD%]) were better than 0.81% (in injections) and 1.859% (in biological fluids), depending on the Pac concentration. The suggested method was successfully applied to estimate Pac in a pharmaceutical formulation (as injections) and in spiked biological fluids (serum and urine), with results showing good accuracy and precision compared to the reference method.
Keywords: Paclitaxel, osmium, complex formation, spectrophotometry
1. Introduction
Paclitaxel (Pac) is a white to light yellow powder. The chemical formula of Pac is C47H51NO14, with a molecular weight of 853.9 g/mol (Figure 1). It is moderately soluble in water but easily soluble in alcohol [1]. Pac was first discovered and isolated from the bark of the Pacific yew (Taxus brevifolia) in 1971 by scientists at the US Environmental Protection Agency. [2]. It was approved for use in the treatment of advanced breast cancer in 1994 by the US Food and Drug Administration [3].
Figure 1.
Chemical structure of Pac (C47H51NO14).
Pac is primarily used to treat various types of cancer, including breast, lung, ovarian, pancreatic, and others [2]. It is given by intravenous injection, usually as part of a multidrug treatment program. Pac inhibits cancer cell division by disrupting microtubules [4]. Accurate quantification of Pac levels is crucial for ensuring effective cancer treatment and monitoring patient response. It is also associated with potential side effects, such as low white blood cell and platelet counts, and nervous system-related complications [5]. Various analytical techniques have been developed and employed for the estimation of Pac, such as biochemical analysis [6], micelle electrophoretic chromatography [7], high-performance liquid chromatography (HPLC) [8–9], liquid chromatography–mass spectrometry (LC/MS) [10], electrophoresis [11], and liquid chromatography–tandem mass spectrometry (LC–MS/MS) [12]. Recent studies have reported a novel method for enhancing sensitivity and selectivity in the determination of Pac, including a three-phase laminar flow microfluidic chip combined with HPLC [13] and high-performance thin-layer chromatography coupled with densitometric analysis (HPTLC-densitometric analysis) [14–15]. Novel electrochemical methods have also emerged as powerful alternatives for the analytical determination of Pac, which have demonstrated excellent sensitivity and selectivity for the detection of Pac, leveraging its electroactive nature through the reversible oxidation–reduction behavior of the Pac core, enabling the quantification of Pac in pharmaceutical formulations and biological matrices using techniques such as differential pulse voltammetry [16] and cyclic voltammetry [17]. Additionally, researchers have explored the development of Pac-loaded polycaprolactone nanoparticles [18], Pac-loaded coated gold nanoparticles [19], and Pac-bonded silver nanoparticles [20] for potential cancer treatment applications. Ultraviolet–visible (UV–Vis) spectrophotometry is one of the simplest techniques used for estimating drug compounds. It is characterized by simple sample preparation, low cost, and analysis that is not time-consuming. Very few UV–Vis spectrophotometric methodologies have been published for the analysis of Pac in bulk. Its pharmaceutical preparations, such as UV spectrophotometry at 230 nm in the presence of phosphate buffer at pH 10 [21] or methanol [22–23], and the first-derivative spectroscopy method have also been used to estimate Pac in the liposomal formulation [24]. This study involves the development of a spectrophotometric method for the determination of Pac in aqueous medium. The method relies on complex formation between Pac and osmium tetroxide (OsO4) as the reagent. The focal aim of this approach is to develop a simple spectrophotometric method for estimating Pac in bulk samples, injections, and biological fluids. The method relies on the formation of a Pac-Os tetroxide complex in aqueous medium.
2. Experimental
2.1. Instrumentation
All Spectrophotometric measurements and absorption spectra were recorded using a double-beam UV–Vis spectrophotometer (Shimadzu UV-1900i-Japan) equipped with 1.0-cm matched fused silica cells. pH values were measured using a professional Benchtop pH meter (Trans Instruments BP3001-Taiwan).
2.2. Chemicals and reagents
High-purity grade chemicals and reagents were used for all experiments.
2.2.1. Pac standard solution (1000 μg/mL)
A total of 0.1000 g of 98% pure Pac obtained from MedKoo Biosciences was weighed and dissolved in 50 mL of ethanol, then diluted to 100 mL with distilled water using a volumetric flask. This solution was stored in a dark container and remained stable for up to one week. This solution was used to prepare a working solution of Pac by simple dilution in a 100-ml volumetric flask [25].
2.2.2. Stock solution of Os (3.93 × 10−2 M)
The stock solution was prepared by dissolving 1.00 g of 98% Os tetroxide (Fluka) in 100 mL of distilled water using a volumetric flask. The solution was then transferred to a brown, tightly sealed bottle. The stock Os solution was stored at −5 °C for 48 h prior to use [26].
2.2.3. Working solution of Os (2 × 10−3 M)
The working solution was prepared by diluting 5.1 mL of the Os stock solution to 100 mL with distilled water in a volumetric flask. The diluted solution was then transferred to a dark container for storage.
2.2.4. Phosphate Buffer Solution (pH 6.8)
A total of 50 mL of 0.1 M 99% potassium phosphate monobasic solution (KH2PO4) obtained from BDH was mixed with 22.4 mL of 0.1 M sodium hydroxide solution (Merck). The mixture was then diluted to 100 mL with distilled water using a volumetric flask [27].
2.2.5. Determination of Pac in injections
Vitrax and Pac (Iranian and German) injections are clear, colorless solutions. They are available at a concentration of 100 mg per 16.7 mL. To prepare 100 μg/mL Pac, three injection solutions were mixed well, and 1.67 mL of each mixture was carefully pipetted into a 100 mL calibrated flask. A total of 10 mL of ethanol was added, and the volume was then diluted to the mark with distilled water. Finally, the prepared injection solutions were transferred to an amber vessel for storage and remained stable for 10 days. To estimate the amount of Pac, an aliquot of the diluted injection solution was taken and analyzed according to the standard procedure.
2.2.6. Estimation procedure for the analysis of Pac in biological fluids
The biological fluid samples were prepared as follows [28–29]. For the urine sample, one mL of a freshly drug-free urine sample from a healthy person was spiked with an appropriate amount of Pac standard solution, then diluted 500-fold with distilled water. The final Pac concentrations ranged from one to 55 mg/mL. A serum sample was prepared by taking five mL of drug-free human blood from a healthy volunteer and centrifuging for 30 min at 4000 rpm. To the one mL of the separated filtrate serum, five mL of acetonitrile was added, and the mixture was mixed well to deproteinize it. The sample solution was then centrifuged for five min at 2500 rpm to separate the protein. A convenient amount of Pac standard solution was added and diluted 1000-fold with distilled water to obtain final Pac concentrations ranging from one to 55 μg/mL.
To estimate the Pac in the fluid sample, one to two mL of biological fluids (urine and serum) were collected and analyzed according to the standard procedure.
3. Essential procedure and calibration curve
Increasing quantities of 0.1–5.5 mL of 100 μg/mL standard Pac solution were added to a series of 10-mL volumetric flasks. To each flask, 2 mL of 2 × 10−3 M working Os tetroxide solution and one mL of phosphate buffer (pH 6.8) were added, and the mixture was mixed well. After three min, the flasks were diluted to the marks with distilled water, and the absorbance of each was measured at 482 nm against a reagent blank. The proposed method demonstrated linearity over the Pac concentration range of 1–55 μg/mL, with an excellent coefficient of determination (R2 = 0.9987) and a molar absorptivity of 3.01 × 10−4 L/mol−1.cm−1, as shown in Figure 2.
Figure 2.
Standard calibration curve for estimating Pac according to the approved method.
4. Results and discussion
4.1. Effect of pH
The effect of pH on the absorbance of the colored product was investigated using a pH meter. The pH measurements indicate that the complex Os-Pac formed at pH 6.8 and exhibited a high absorbance (0.2119) at 482 nm. The results are illustrated in Figure 3.
Figure 3.
Effect of pH on absorbance of Os-Pac complex.
Different portions (1–4 mL) of various buffer solutions (B1 = imidazol-HCl, B2 = maleic acid-Tris-NaOH, B3 = KH2PO4-NaOH, B4 = triethanolamine-hydrochloric acid-NaOH, B5 = sodium hydrogen maleate-NaOH, and B6 = Na2HPO4-NaH2PO4) of pH 6.8 were studied in terms of their effectiveness on the absorbance of the complex (Os-Pac) formed at a wavelength of 482 nm (Figure 4).
Figure 4.
Effect of the amounts of various types of buffer solutions on absorbance.
The results in Figure 4 indicate that 1 mL of phosphate buffer solution (B3) at pH 6.8 is the optimal amount to produce the (Os-Pac) complex. Therefore, this volume of the buffer solution was employed in subsequent experiments.
4.2. Influence of Os concentration
The influence of one mL of diverse concentrations from 1 × 10−3 to 3 × 10−3 M of Os tetroxide solutions on the absorbance of the colored product in the presence of 1 mL phosphate buffer solution was studied. The solutions were diluted to the marks with distilled water, and the absorbance of each was measured at 482 nm against its reagent blank. The results are summarized in Table 1 and indicate that a concentration of 2 × 10−3 M Os tetroxide is optimal, therefore it was used for the subsequent investigations.
Table 1.
Influence of osmium concentration on the absorbance of the resulting complex
| Osmium tetroxide (M) | 1×10−3 | 1.5×10−3 | 2×10 −3 | 2.5×10−3 | 3×10−3 |
| Absorbance | 0.2079 | 0.2881 | 0.3621 | 0.3544 | 0.3472 |
4.3. Os amount effect
The effect of adding varying amounts (1–2.5 mL) of Os tetroxide solution (2 × 10−3 M) to increasing amounts (50–200 μg) of Pac on absorbance was reviewed. The results, shown in Table 2, revealed that 2 mL of 2 × 10−3 M Os tetroxide solution (R2 = 0.9929) is the optimal amount for the formation of the Os-Pac complex; therefore, it was used in the recommended procedure.
Table 2.
Effect of osmium amount on absorbance of the complex formed
| ml of 2×10−3M OsO4 solution | Absorbance/μg of Paclitaxel added | R2 | ||||
|---|---|---|---|---|---|---|
| 50 | 75 | 100 | 150 | 200 | ||
| 1.0 | 0.0732 | 0.2095 | 0.2707 | 0.4318 | 0.5418 | 0.9894 |
| 1.5 | 0.1154 | 0.2432 | 0.3417 | 0.4828 | 0.6099 | 0.9902 |
| 2.0 | 0.1755 | 0.3123 | 0.4021 | 0.5534 | 0.6998 | 0.9929 |
| 2.5 | 0.1242 | 0.2858 | 0.3839 | 0.5102 | 0.6684 | 0.9853 |
| 3.0 | 0.0994 | 0.2821 | 0.3775 | 0.4118 | 0.6739 | 0.9583 |
The influence of various types of surfactant solutions, cetyltrimethylammonium bromide (CTAB), sodium dodecyl sulfate (SDS), cetylpyridinium chloride (CPC) (1 × 10−3M), and Triton X-100 (1%), on the absorbance of the complex (Os-Pac) formed was also carried out. The experimental investigations showed that the presence of these surfactant agents adversely affected the absorbance of the resulting complex; therefore, they were excluded from the essential procedure.
4.4. Temperature and reaction time effect
The influence of four temperatures (10, 24, 40, and 50 °C) at different time intervals (1–10 min) on the absorbance of the resulting Os-Pac complex was examined using a thermostatic water bath, with temperature monitored with digital thermometers. The results, as shown in Figure 5, confirmed that the reaction of Os with Pac at pH 6.8 required at least 3 min to complete at room temperature (24 ± 2 °C).
Figure 5.
Effect of temperature and reaction time on the absorbance.
4.5. Addition order effect
The effect of the order of addition of the reaction components on the method’s sensitivity was investigated. The experimental results have proved that the sequence of addition of the reactants denoted as (Pac + Os + buffer solution) to obtain the highest absorbance value (0.4233) of the complex. Under ideal conditions, the effect of time on the color stability of the (Os-Pac) complex was also assessed by measuring the absorbance of three diverse Pac concentrations (5, 10, and 20 μg/mL) at different time points against a reagent blank at 482 nm. As illustrated in Figure 6, the resulting complex remains stable for more than 60 min.
Figure 6.
Time influence on the color stability of Os-Pac complex.
5. Final absorption spectrum
After establishing the optimal conditions, as outlined in Table 3, for the reaction of Pac with Os tetroxide in phosphate buffer, the final absorption spectrum of the colored product was plotted in Figure 7.
Table 3.
Summary of the optimal conditions for the determination of paclitaxel
| Parameters | Value |
|---|---|
| Os concentration (Mole.L−1) | 2×10−3 |
| Os amount (mL) | 2 |
| PH | 6.8 |
| Type of buffer used | Phosphate |
| Volume of buffer used (mL) | 1 |
| Selected maximum wavelength, λmax (nm) | 482 |
| Time needed to form Os-Pac complex | 3 |
| Temperature (°C) | RT |
| Stability of Os-Pac complex period time (minute) | 60 < |
Figure 7.
(a) Final absorption spectrum of 4 μg/mL Pac measured vs. blank solution, (b) absorption spectrum of the blank solution vs. distilled water.
The spectrum in Figure 7 reveals that the complex Os-Pac formed exhibits a maximum absorption peak at a wavelength of 482 nm, in contrast to its reagent blank solution [a solution containing all components of the reaction except the analyte of interest (Pac)], which shows a low absorbance value at the same wavelength.
6. Quantification
Analysis of the Os-Pac complex revealed key metrics, including Beer′s law range, absolute molar absorptivity, recovery percentage, RSD%, limit of detection (LOD), and limit of quantitation (LOQ) values, which were measured and the results are listed in Table 4, indicating that the proposed procedure is both precise and highly sensitive. The linearity of the calibration curve is represented by the regression equation (y = 0.00352x + 0.03417), with a correlation coefficient of 0.9987, highlighting a strong linear relationship between absorbance and concentration. Consequently, the Pac content in pharmaceutical preparations and biological fluids can be accurately determined using this straight-line equation.
Table 4.
Calculated analytical values for the proposed method
| Parameters | Value |
|---|---|
| Linearity range, μg /mL | 1 −55 |
| Molar absorptivity, L/mol.cm | 3.01×104 |
| Sandell’s sensitivity, μg/cm2 | 0.0284 |
| LOD, μg /mL | 0.0098 |
| LOQ, μg /mL | 0.0328 |
| Slope (b)* | 0.0352 |
| Intercept (a)* | 0.03417 |
| Determination coefficient (R2) | 0.9987 |
Regression equation Y = a X + b, where Y is [Pac] in μg/ml.
7. Stoichiometry of the product
Under the ideal conditions of the suggested procedure, the Job and slope-ratio methods have been applied [29] to determine the molar ratio of the resulting Os-Pac complex formed from the reaction of Os with Pac. In both methods, an equal concentration of 1.171 × 10−4 M of Pac and Os was used.
In Job’s method, increasing amounts (0–2 mL) of Pac solution were reacted with complementary quantities (two–0 mL) of Os solution according to the suggested procedure, giving a total volume of two mL in 10 mL calibrated flasks. The solutions were diluted with distilled water, and the absorbance of each was then measured at 482 nm against a reagent blank. The results in Figure 8 show that the mole ratio of the complexes formed is 2:1 (Pac:Os).
Figure 8.
Plot of Job’s method for (Os-Pac) complex formation.
In the slope-ratio method, two calibration curves were prepared. The first one was prepared by adding increasing amounts of 0.3–two mL of Os solution to a fixed amount of Pac solution (two mL), and in the second curve, increasing amounts of 0.3–two mL of Pac solution were added to a fixed amount of Os solution (two mL) using 10 mL calibrated flasks. The volumes of all flasks were made up to the marks with distilled water, and their absorbance values were measured at 482 nm. The results, illustrated in Figure 9, showed that the Pac: Os ratio in the complex is 2:1.
Figure 9.
Slope-ratio method curves for the Os-Pac complex.
According to the stoichiometry results, the suggested chemical structure for the (Os-Pac) complex is shown in the Scheme.
Scheme.
Suggested chemical reaction of Pac with Os.
8. Application
The applicability of the proposed method for the determination of Pac in commercially available fluids (injections) from three different sources, as well as in biological fluids (serum and urine), was studied using three different amounts of 50, 100, and 200 μg of Pac injection (which must be within the range of Beer’s law for the proposed method). The results are listed in Tables 5 and 6.
Table 5.
Estimation of Pac in the injections by using the proposed method.
| Dosage | Certified value | Pac added (μg) | Pac found (μg) * | Reco. *(%) ± RSD*(%) | R.E.* (%) | Measured value (mg) |
|---|---|---|---|---|---|---|
| Vitax (Türkiye) | 100 mg/mL 16.7mL |
50 | 49.14 | 98.28 ± 0.76 | −1.72 | 98.28 |
| 100 | 100.34 | 100.34 ± 0.44 | 0.34 | 100.34 | ||
| 200 | 202.18 | 101.09 ± 0.27 | 1.09 | 101.09 | ||
| Pac (Iran) | 6 mg/mL | 50 | 48.71 | 97.42 ± 0.81 | −2.58 | 5.85 |
| 100 | 98.32 | 98.32 ± 0.46 | −1.68 | 5.90 | ||
| 200 | 200.86 | 100.43 ± 0.56 | 0.86 | 6.03 | ||
| Pac (Germany) | 6 mg/mL | 50 | 49.60 | 99.19 ± 1.31 | −0.81 | 5.95 |
| 100 | 100.05 | 100.05 ± 0.43 | 0.05 | 6.00 | ||
| 200 | 201.34 | 100.67 ± 0.75 | 1.34 | 6.04 |
Average of five estimations
Table 6.
Estimation of Pac in the biological fluids.
| sample | mL of sample | Pac found (μg) * | Reco. *(%) ± RSD*(%) | R.E.*(%) |
|---|---|---|---|---|
| Serum | 1 | 49.34 | 98.67 ± 0.081 | −1.33 |
| 96.98 | 96.98 ± 0.271 | −3.02 | ||
| 194.9 | 97.45 ± 0.263 | −2.55 | ||
| 2 | 51.83 | 103.66 ± 1.859 | 3.66 | |
| 100.46 | 100.45 ± 0.090 | 0.45 | ||
| 204.92 | 102.58 ±0.665 | 2.58 | ||
|
| ||||
| Urine | 1 | 48.44 | 96.87 ±1.751 | −3.13 |
| 97.02 | 97.02 ±0.092 | −2.98 | ||
| 204.76 | 102.38 ±0.673 | 2.38 | ||
| 2 | 48.87 | 97.74 ±0.431 | −2.26 | |
| 102.12 | 102.12 ± 1.192 | 2.12 | ||
| 202.56 | 101.28 ± 0.607 | 1.28 | ||
Average of five estimations
9. Evaluation of the results of the proposed method
The performance of the proposed method for estimating Pac at two concentrations (five and 10 μg/mL) in the pharmaceutical form and biological fluids has been evaluated using a t-test. Table 7 shows that the experimental t-value was better than the tabulated value at the 95% confidence level; the results of the proposed method are not statistically significant. This indicates the feasibility of using the proposed method to determine Pac in drug formulations and biological fluid samples reliably.
Table 7.
Evaluation the proposed method in pharmaceutical form and biological fluids.
| Sample | Pac added (μg) | Pac found (μg)* | t-exp.# |
|---|---|---|---|
| Vitax (Türkiye) | 50 | 50.21 | 1.039 |
| 100 | 99.97 | 0.145 | |
| Pac (Iran) | 50 | 50.18 | 0.661 |
| 100 | 100.15 | 0.433 | |
| Pac (Germany) | 50 | 49.82 | 0.380 |
| 100 | 99.57 | 0.758 | |
| Serum ** | 50 | 49.24 | 1.176 |
| 100 | 98.87 | 1.973 | |
| Urine ** | 50 | 49.36 | 2.066 |
| 100 | 101.56 | 1.869 |
Average of five estimations,
2 mL of sample used.
, tabulated t-value at 95% confidence level is equal to 2.776, with degrees of freedom (N−1 = 4).
10. Validity of the proposed method
The standard additions method was applied for the purpose of proving the efficiency and selectivity of the proposed spectrophotometric method for determining Pac in its pharmaceutical preparations (injection forms) and to ensure that it was free from the interference of additives prove that it is free of interferences, The results in Figure 10 and Table 8 indicate that the results of the standard additions method agree well with that results of the proposed method within an adequate range of error.
Figure 10.
Standard addition plots for the estimation of Pac in the injections.
Table 8.
Standard additions method for the estimation of Pac in the injection.
| Injection | Certified value | Pac (μg) | Recovery (%) | Measured value (mg) | ||
|---|---|---|---|---|---|---|
|
|
|
|||||
| Present | Found | Proposed method | Standard addition | |||
| Vitax | 100 mg/ 16.7mL | 50 | 49.2 | 98.40 | 101.41 | 98.4 |
| 100 | 102.40 | 102.40 | 100.48 | 102.4 | ||
| Pac | 6 mg/mL | 50 | 48.71 | 97.42 | 5.87 | 5.85 |
| 100 | 97.23 | 97.23 | 5.82 | 5.83 | ||
11. Comparison of the proposed methods
Table 9 compares some analytical variables of the recommended method with those of other literature spectrophotometric methods. The suggested method demonstrates high sensitivity and broad applicability.
Table 9.
Comparison of the proposed method with published methods.
| Parameter | Present method | Published method | |||||
|---|---|---|---|---|---|---|---|
|
| |||||||
| [22] | [23] | [24] | [30] | [31] | [32] | ||
| Method | complex formation | solvent system | solvent system | first-derivative | ultraviolet spectroscopic | copolymer nanoparticles | |
| Reagent | Os tetroxide | methanol | methanol | isopropanol | methanol | methanol: phosphate buffer | *PLGA- AFT |
| lmax (nm) | 482 | 230 | 230 | 246 | 230 | 230 | 260 |
| Linearity range (μg/mL) | 1–55 | 2–20 | 1.28 ± 0.346 mg/mL | 6–24 | 5–55 | 2–20 | 80–120% |
| ɛmax (l/mol.cm) | 3.01 × 104 | ---- | ----- | ---- | --- | ----- | ----- |
| pH | 6.8 | 7.4 | ----- | ---- | 10 | ------ | ----- |
| Buffer solution | phosphate buffer | phosphate buffer | ------ | ---- | phosphate buffer | 7.4 | ------ |
| Color of the product | yellowish-brown | colorless | colorless | colorless | 0.7932 | colorless | colorless |
| LOD (μg/mL) | 0.0098 | ---- | 0.030 mg/mL | 0.9969 | 0.7932 | 0.715627 | ------- |
| LOQ (μg/mL) | 0.0328 | ---- | 0.090 mg/mL | 3.3229 | 2.4038 | 2.168565 | ----- |
| Recovery range (injections) (%) | 97.42–100.34 | 99.82–100.48 | ----- | 98.97–102.05 | ----- | 99.42–100.77 | 100.77 |
| Recovery range (fluids) (%) | 96.87 to 103.66 | ------ | |||||
| RSD (injections) (%) | ≤1.31 | ≤1.19 | <0.05 | ≤1.31 | 0.5640 | 1.386 | ≤2 |
| RSD (fluids) (%) | ≤1.86 | ||||||
| Application of the method | Injection, serum, and urine | Tablet | Pac | Liposomal formulation | Pharmaceutical Formulation | Dosage forms | Pac nanoparticles conjugated with a protein vector |
Pac-poly (lactic-glycolic acid) (PLGA) copolymer nanoparticles-alpha-fetoprotein (AFT)
12. Conclusion
A direct spectroscopic method has been proposed to estimate the pharmaceutical compound Pac in pharmaceutical preparations and biological fluids. The method was based on the formation of a water-soluble complex by reacting Pac with Os tetroxide in an aqueous medium at pH 6.8. The resulting complex displayed a maximum absorption peak at 482 nm. The proposed method is sensitive, rapid, and accurate, and does not require complex sample preparation, making it suitable for the routine estimation of Pac. The analytical performance characteristics, such as linearity, accuracy, precision, and selectivity, were evaluated according to the guidelines. Furthermore, the proposed method offers advantages over existing methods in terms of simplicity, cost-effectiveness, and suitability for quality control. Moreover, the proposed approaches do not include temperature control, extraction steps, or specialized equipment. The proposed procedure was effectively employed for the assay of Pac in injections and spiked biological fluids (serum and urine). To assess the study’s originality, this manuscript introduces a novel approach for estimating Pac, highlighting the scarcity of available spectrophotometric methods for its determination. This research addresses a significant gap in the existing literature by offering a visible, reliable, and efficient method for estimating Pac, an area that has received limited attention. The proposed method is characterized by its ease of use, rapid execution, and the stability of the formed complex, all of which are crucial in pharmaceutical analysis, where efficiency and accuracy are paramount. Furthermore, the method demonstrates high selectivity for Pac, even in the presence of interfering substances, making it essential for accurate estimation in biological samples. The ability to accurately quantify Pac in biological matrices is vital for therapeutic monitoring and pharmacokinetic studies, underscoring the relevance of this research for clinical applications. By addressing these critical aspects, this study makes a significant contribution to the field and enhances the methodologies available for Pac estimation.
Footnotes
Author contributions: All authors read and approved the final version of the manuscript, beginning with Basima A.A. Saleem, who contributed to the conception and design of the study, supervision, and final revision of the manuscript. Salim A. Mohammed participated in data collection, analysis, and drafting, and Amer Th. Al-Taee contributed to the literature review, data interpretation, and manuscript editing.
References
- 1.British Pharmacopoeia. II The Stationary Office; London, UK: 2022. pp. II-52l–II-526. [Google Scholar]
- 2. Gallego-Jara J, Lozano-Terol G, Sola-Martínez RA, Cánovas-Díaz M, de Diego Puente T. A compressive review about Taxol®: History and future challenges. Molecules. 2020;25(24):5986. doi: 10.3390/molecules25245986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Xie F, De Thaye E, Vermeulen A, Van Bocxlaer J, Colin P. A dried blood spot assay for paclitaxel and its metabolites. Journal of Pharmaceutical and Biomedical Analysis. 2018;148:307–315. doi: 10.1016/j.jpba.2017.10.007. [DOI] [PubMed] [Google Scholar]
- 4. Jivani A, Shinde RK. A comprehensive review of taxane treatment in breast cancer: Clinical perspectives and toxicity profiles. Cureus. 2024;16(4):e59266. doi: 10.7759/cureus.59266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Nehate C, Jain S, Saneja A, Khare V, Alam N, et al. Paclitaxel formulations: challenges and novel delivery options. Current Drug Delivery. 2014;11(6):666–686. doi: 10.2174/1567201811666140609154949. [DOI] [PubMed] [Google Scholar]
- 6. Morais S. A tubulin-based fluorescent polarization assay for paclitaxel. Analytical Biochemistry. 2003;321(1):44–49. doi: 10.1016/s0003-2697(03)00436-6. [DOI] [PubMed] [Google Scholar]
- 7. Rodriguez J. Determination of morphine, codeine, and paclitaxel in human serum and plasma by micellar electrokinetic chromatography. Journal of Separation Science. 2012;35(17):2297–2306. doi: 10.1002/jssc.201200375. [DOI] [PubMed] [Google Scholar]
- 8. Khan I. A simple, rapid and sensitive RP-HPLC-UV method for the simultaneous determination of sorafenib and paclitaxel in plasma and pharmaceutical dosage forms: Application to pharmacokinetic study. Journal of Chromatography B. 2016;1033:261–270. doi: 10.1016/j.jchromb.2016.08.029. [DOI] [PubMed] [Google Scholar]
- 9. Gaïes E, Jebabli N, Ben Said D, Charfi R, El Jebari H, et al. Development and validation method for estimation paclitaxel in plasma. La Tunisie Medicale. 2020;98(6):496–500. [PubMed] [Google Scholar]
- 10. Hendrikx JJMA, Hillebrand MJX, Thijssen B, Rosing H, Schinkel AH, et al. A sensitive combined assay for the quantification of paclitaxel, docetaxel and ritonavir in human plasma using liquid chromatography coupled with tandem mass spectrometry. Journal of Chromatography B. 2011;879(28):2984–2990. doi: 10.1016/j.jchromb.2011.08.034. [DOI] [PubMed] [Google Scholar]
- 11. Zhang L, Qu F, Hu M, Ding J, Lou B. Capillary zone electrophoresis-based cytotoxicity analysis of Caco-2 cells. Electrophoresis. 2012;33(5):834–840. doi: 10.1002/elps.201100382. [DOI] [PubMed] [Google Scholar]
- 12. Brikia M, Murisier A, Guidi M, Seydoux C, Buclin T, et al. Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) methods for the therapeutic drug monitoring of cytotoxic anticancer drugs: An update. Journal of Chromatography B. 2024:124039. doi: 10.1016/j.jchromb.2024.124039. [DOI] [PubMed] [Google Scholar]
- 13. Cai Q, Peng H, Meng J, Yan Y, Zeng Y, et al. Simultaneous determination of free and total paclitaxel in blood in a three-phase laminar flow microchip. Journal of Chromatography A. 2020;1627:461391. doi: 10.1016/j.chroma.2020.461391. [DOI] [PubMed] [Google Scholar]
- 14. Das T, Pandey DK, Shekhawat MS, Dey A, Malik T. Quantification of Tissue-Specific Paclitaxel in Himalayan Yew Using HPTLC-Densitometric Analysis, Assessment of Toxicological Activity, and Tissue-Specific Evaluation of Antioxidant Activity. ACS Omega. 2023;8(35):32108–32118. doi: 10.1021/acsomega.3c04309. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Sakhi M, Khan A, Khan I, Iqbal Z, Khan SI, et al. A new sensitive HPLC/UV method for simultaneous determination of paclitaxel, sorafenib, and omeprazole in standard solutions and spiked plasma: Application to in-vitro and in-vivo evaluation of paclitaxel polymeric nanoformulations. Tropical Journal of Pharmaceutical Research. 2021;20(9):1949–1959. doi: 10.4314/tjpr.v20i9.23. [DOI] [Google Scholar]
- 16. Tajik S, Taher MA, Beitollahi H, Torkzadeh-Mahani M. Electrochemical determination of the anticancer drug taxol at a ds-DNA modified pencil-graphite electrode and its application as a label-free electrochemical biosensor. Talanta. 2015;134:60–64. doi: 10.1016/j.talanta.2014.10.063. [DOI] [PubMed] [Google Scholar]
- 17. Lang J, Wang W, Zhou Y, Guo D, Shi R, et al. Electrochemical behavior and direct quantitative determination of paclitaxel. Frontiers in Chemistry. 2022;10:1–9. doi: 10.3389/fchem.2022.834154. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Ünal S, Doğan O, Aktaş Y. Paclitaxel-loaded polycaprolactone nanoparticles for lung tumors; formulation, comprehensive in vitro characterization and release kinetic studies. Journal of Faculty of Pharmacy of Ankara University. 2022;46(3):1009–1029. doi: 10.33483/jfpau.1161238. [DOI] [Google Scholar]
- 19. Kharazmi A, Attaran N. Evaluation of the parameters affecting the loading of anticancer drug Paclitaxel on coated gold nanoparticles for breast cancer treatment. IET Nanobiotechnology. 2023;17:234–245. doi: 10.1049/nbt2.12121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20. Danışman-Kalındemirtaş F, Kariper İA, Hepokur C, Erdem S. Selective cytotoxicity of paclitaxel bonded silver nanoparticle on different cancer cells. Journal of Drug Delivery Science and Technology. 2021;61:102265. doi: 10.1016/j.jddst.2020.102265. [DOI] [Google Scholar]
- 21. Trynda-Lemiesz L, Łuczkowski M. Human serum albumin: spectroscopic studies of the paclitaxel binding and proximity relationships with cisplatin and adriamycin. Journal of Inorganic Biochemistry. 2004;98(11):1851–1856. doi: 10.1016/j.jinorgbio.2004.08.015. [DOI] [PubMed] [Google Scholar]
- 22. Kesarwani P, Tekade RK, Jain NK. Spectrophotometric estimation of paclitaxel. International Journal of Advances in Pharmaceutical Sciences. 2011;2:29–32. [Google Scholar]
- 23. Sugo K, Ebara M. A simple spectrophotometric evaluation method for the hydrophobic anticancer drug paclitaxel. PeerJ Analytical Chemistry. 2020;2:e3. doi: 10.7717/peerj-achem.3. [DOI] [Google Scholar]
- 24. Barbosa MV, Monteiro LOF, Malagutti AR, Oliveira MC, Carvalho-Junior AD, et al. Comparative study of first-derivative spectrophotometry and high-performance liquid chromatography methods for quantification of paclitaxel in liposomal formulation. Journal of the Brazilian Chemical Society. 2015;26(7):1338–1343. doi: 10.5935/0103-5053.20150100. [DOI] [Google Scholar]
- 25. Wang TH, Wang HS, Soong YK. Paclitaxel-induced cell death: where the cell cycle and apoptosis come together. Cancer. 2000;88(11):2619–28. doi: 10.1002/1097-0142(20000601)88:11<2619::aid-cncr26>3.0.co;2-j. [DOI] [PubMed] [Google Scholar]
- 26.Mijs WJ, de Jonge CRHI. Organic Syntheses by Oxidation with Metal Compounds. New York: Springer Science and Business Media; 1986. pp. 660–685. [Google Scholar]
- 27.Perrin DD, Dempsey B. Buffers for pH and Metal Ion Control. London: Chapman and Hall Ltd; 1974. p. 139. [Google Scholar]
- 28. El-Didamony AM, Ali II. New spectrofluorimetric and spectrophotometric methods for the determination of the analgesic drug, nalbuphine in pharmaceutical and biological fluids. Journal of Biological Chemistry and Luminescence. 2013;28(5):745–750. doi: 10.1002/bio.2428. [DOI] [PubMed] [Google Scholar]
- 29. Manzoori JL, Abulhassani J, Niaei N. Spectrofluorimetric determination of doxorubicin in spiked serum and urine samples. Journal of Chemical Health Risks. 2014;4(4):17–24. [Google Scholar]
- 30. Indrayani R, Doijad RC, Mohite SK. Validated spectrophotometric method for estimation of paclitaxel in bulk and pharmaceutical formulation. International Journal of Pharmacy. 2017;7(1):68–72. [Google Scholar]
- 31. Mishra V, Tambuwala MM, Mishra Y. Development and validation of ultraviolet spectroscopic analytical method for biopharmaceutical classification system class IV anticancer drug, paclitaxel. Indian Journal of Pharmaceutical Sciences. 2024;86(4):1601–1605. doi: 10.36468/pharmaceutical-sciences.1419. [DOI] [Google Scholar]
- 32. Sokol MB, Sycheva YV, Yabbarov NG, Zabolotskii AI, Mollaev MD, Fomicheva MV, et al. Validation of a UV-spectrophotometric method for quantitative determination of paclitaxel in a targeted delivery system based on poly(lactic–glycolic acid) copolymer nanoparticles. Pharmaceutical Chemistry Journal. 2020;54(8):846–850. doi: 10.1007/s11094-020-02285-w. [DOI] [Google Scholar]











