The consequences of using statistical tests on proxy measurements in place of gold standard measurements: an application to magnetic resonance spectroscopy

Michael Treacy 1, Christoph Juchem 2, Karl Landheer 3,✉
PMCID: PMC12824271  PMID: 41449224

Abstract

The use of proxy measurements in biomedical science is ubiquitous, due to the infeasibility or unavailability of gold-standard (i.e., most precise, accurate, and/or validated) measurements. For example, in magnetic resonance spectroscopy (MRS), short-echo time (TE) sequences are frequently employed to estimate difficult-to-measure metabolites such as GABA, despite J-difference editing being the recommended gold-standard due to improved metabolic specificity. This work investigates the critical relationship between the correlation of proxy and gold-standard measurements and the associated false positive (FPR) and false negative (FNR) rates of statistical tests performed on proxy measurements. Through statistical simulations, we demonstrate that even moderately high correlations (0.6–0.7), reported in the literature for short-TE vs. J-edited estimated GABA, can lead to drastically inflated FPRs and FNRs. We show that these rates are highly sensitive to the magnitude of differential bias in the proxy measurement (δ) and the underlying true effect size (Δ). For instance, a small, unmeasured bias in short-TE estimated GABA, potentially arising from macromolecule contamination, can substantially inflate FPRs. Conversely, imperfect correlation can substantially reduce statistical power, leading to high FNRs, which may explain some discrepancies within the literature. Although this work focuses specifically on the relationship between short-TE and MEGA-edited GABA, the arguments presented here apply more broadly to other difficult-to-measure metabolites in MRS (e.g., glutathione, 2-hydroxyglutarate), or generally to any circumstance where statistical tests are performed on the readily available proxy measurements in place of gold-standard measurements.

Keywords: Magnetic resonance spectroscopy, MEGA-edited GABA, Short-TE MRS, Hypothesis testing

Subject terms: Biochemistry, Chemistry

Introduction

In biomedical science, proxy measurements are widely used in place of gold-standard measurements because the latter are often infeasible (due to resource or ethical constraints), impossible (due to inherent physical or technological limitations), or simply unavailable in existing datasets. In magnetic resonance spectroscopy (MRS), short-echo time (TE) sequences are appealing for several factors: wide availability (preinstalled stock PRESS1 and STEAM2 sequences on all major vendor platforms), high signal-to-noise ratio due to reduced T2-weighting3, reduced sensitivity to variations in T2 values, and easy quantification of typical major metabolites3–5 which may serve as a reference or may also be of interest. Short-TE sequences suffer from strong spectral overlap (Fig. 1), and as such J-editing modules such as MEGA6 have been developed to improve metabolic specificity7–9, and are the recommended standard9,10 for metabolites such as γ-aminobutyric acid (GABA), 2-hydroxyglutarate and glutathione. These metabolites are characterized by being low in amplitude and heavily overlapped with other signals, particularly macromolecules which have poorly characterized spectral shape11. Regardless, there are numerous examples in the literature of short-TE sequences being used to quantify GABA12–22, glutathione13,15,17,23,24 and 2-hydroxyglutarate25–27, to name a few.

Fig. 1.

Fig. 1

Synthetic spectrum of a typical short-TE (30 ms) PRESS sequence with repetition time = 2 s generated via synMARSS49,50 at 3T in the absence of noise with concentrations typical for healthy brain tissue. Note the low relative amplitude of difficult-to-quantify metabolites such as GABA and glutathione compared to numerous other components directly overlapping them, most notably the macromolecules. No individual moiety of either metabolite is free from spectral overlap with much more prominent resonances, which results in considerable quantification errors and moderate correlation with MEGA-edited quantification. Metabolites simulated include ascorbate (Asc), aspartate (Asp), creatine (Cr), γ-aminobutyric acid (GABA), macromolecules, glutathione (GSH), glucose (Glc), glutamine (Gln), glutamate (Glu), lactate (Lac), N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), phosphorylethanolamine (PE), total choline (tCho), taurine (Tau), myo-inositol (mI), scyllo-inositol (sI).

Provided that the correlation is sufficiently high between the gold-standard measurement (the focus of this work will assume this is MEGA-edited GABA) and the proxy measurement (i.e., short-TE measured GABA), simpler approaches may be appropriate. We investigate what exactly constitutes a “sufficiently high correlation” here. This is achieved using Monte Carlo simulations, and we demonstrate that the false positive rate (FPR) and false negative rate (FNR) are strongly dependent on the correlation between measurements from MEGA- and short-TE estimate measurements. Even for the moderately-high correlations (0.6 to 0.7), representative of those from the literature for this application, the FPR and FNR can be drastically higher than reported, suggesting that results which rest on the assumption of perfect correlation need to be interpreted with increased caution28,29. A preliminary version of this work has previously been presented in abstract form30.

Methods

We denoted Inline graphic and Inline graphic to be the random variables sampled from the gold-standard distributions (e.g., MEGA-edited measured concentrations for the metabolite of interest) of the control groups and cases, respectively. For example, Inline graphic could represent concentrations of GABA from subjects in a disease population31, or concentrations after a functional stimulus19. Similarly, we denoted Inline graphic and Inline graphic as proxy variables (i.e., short-TE measured GABA concentrations) of the control and case population, respectively. A conceptual diagram of this methodology is provided in Fig. 2 and a full derivation of all expressions and rationale for approximations are provided in the Appendix.

Fig. 2.

Fig. 2

Conceptual diagram demonstrating the gold-standard distributions (left) and proxy distribution for a correlation of 0.6 (middle) and a near-perfect correlation of 0.99 (right). The case when Inline graphic but Inline graphic is depicted in the top row, where false negatives may occur. In the top row it can be seen that for a moderate correlation there can be a substantial reduction in means (and hence a higher chance to obtain a false negative), which is resolved as the correlation approaches 1. Similarly, in the bottom row for a moderate correlation there can be a substantial difference in the mean of the proxy distributions, which is then resolved as the correlation approaches 1. The purpose of this work is to investigate the relationship at which a correlation becomes “sufficiently high enough” to not drastically inflate false positive and false negative rates.

We model the gold-standard measurements by

graphic file with name d33e349.gif 1
graphic file with name d33e353.gif 2

where Inline graphic, and Inline graphic denotes sampling from the normal distribution with mean Inline graphic and standard deviation Inline graphic, both with units of millimole (mM) for concentrations, or unitless for relative concentrations. The true effect (i.e., differences in means between Inline graphic and Inline graphic) is given by Inline graphic. Inline graphic and Inline graphic represents the true mean and variance of the unobserved biological signal S, respectively. Inline graphic is the non-biological measurement variance of the gold standard variables.

The proxy variables are then modeled as a linear combination of the true biological signal, S, and an independent noise/contamination component, Inline graphic

graphic file with name d33e404.gif 3
graphic file with name d33e408.gif 4

where Inline graphic Inline graphic and Inline graphic represent the mean and variance of the contamination signal Inline graphic due to the use of proxy variables. Inline graphic is the sensitivity coefficient (i.e., how sensitive the proxy measurement is to the true signal, and Inline graphic is the contamination coefficient. Inline graphic represents differential bias introduced due to the use of proxy variables that is present only in cases and not controls (or vice versa). Non-zero differential bias could arise in scenarios where one is measuring a difference between cases and controls that is assumed to be due to a change in GABA concentration but is actually due to a different reason (e.g., macromolecule changes in cases and controls). Further exploration of potential causes of non-zero differential bias are given in the Discussion. In order to re-parameterize Inline graphic and Inline graphic in terms of the correlation between the proxy and gold-standard measurements, we must introduce the variance ratio, defined to be Inline graphic, where Inline graphic (see Appendix).

We calculated the false positive and false negative rates numerically by running Monte Carlo simulations, where random variables representing the concentrations of proxy variables were generated according to the model defined by Eqs. 1–4. All simulations were performed with 500,000 iterations per set of parameters with NumPy version 2.1.3 and all statistical tests were two-sided independent Welch’s t-tests performed via SciPy version 1.15.3. We performed statistical tests on the proxy variables (i.e., Inline graphic and Inline graphic) to test hypotheses about the underlying gold-standard variables. Specifically, the null hypothesis (Inline graphic) was that no true difference exists between the gold-standard means (Inline graphic), and the alternative hypothesis (Inline graphic) was that a true difference does exist (Inline graphic. The code to reproduce all statistical simulations is available at: github.com/karllandheer/GoldStandardVsProxy.

To investigate FPRs, we set Inline graphic (i.e., Inline graphic is true, no true difference exists between the means of the gold-standard variables) and Inline graphic, (i.e., a differential bias is introduced in the estimation of cases but not controls of the proxy variables, or vice versa). To investigate FNRs, we set Inline graphic (no differential bias) but Inline graphic (Inline graphic is false). Initially, we array across a large range of possibilities of Inline graphic or Inline graphic (from 0.2 to 2.2 mM) to demonstrate that in certain scenarios both FPR and FNR can be strongly sensitive to correlation and refer to these as the “theoretical simulations”. The parameter Inline graphic was set to 1 mM, and simulations are independent of the choice of Inline graphic and Inline graphic (as shown in the Appendix). We choose the nominal false-positive rate Inline graphic and Inline graphic. We set VR = 1 (as the test statistic is independent of it if Inline graphic is fixed, as shown in the Appendix) and three values for Inline graphic ∈ {0.5, 1, 2} when Inline graphic. For Inline graphic the test statistic is independent of Inline graphic, hence we do not array over it. We also investigate how the false positive and false negative rate changes as we sweep across a range of Inline graphic values.

We then performed statistical simulations with experimental values from the literature and refer to these as the “literature simulations”. First, to investigate the influence of correlation and the differential bias δ on the FPR, we used values from the literature which report statistically significant difference in the concentration of GABA in the visual cortex before and after behavioral training as assessed by short-TE MRS at 7T19. We assume the reported sample values are reflective of the population values, i.e., Inline graphic, Inline graphic, Inline graphic. We use their values of Nsamples = 25, Inline graphic. If we assume the null hypothesis is correct (i.e., Inline graphic then Inline graphic As we only have empirical values for Inline graphic and Inline graphic (0.72 at 7T32), we thus must assume certain values for Inline graphic and VR. If we set Inline graphic, then Inline graphic = 1.2. However, we investigate how sensitive these results are to Inline graphic by also performing simulations with Inline graphic and Inline graphic while keeping Inline graphic fixed, and since Inline graphic is not known, but rather Inline graphic, we must also simulate a range of variance ratios Inline graphic ∈ {0.5, 1, Inline graphic} (as explained further in the derivation of the t-statistic section in the Appendix). We provide the mathematical context of how such a Inline graphic may arise due to small macromolecule contamination in the Discussion.

To investigate the influence of correlation on FNR, we then used values from the literature which used short-TE to estimate GABA at 3T but failed to find a difference between ALS subjects12. The relevant values from this study are Inline graphic (cases/controls) a correlation of 0.58 (previously measured at 3T16), Inline graphic and Inline graphic. Previously, it was observed that ALS patients had a 16% reduction in GABA (1.42 in ALS patients vs 1.70 in healthy controls33), thus we assumed the true effect size is Inline graphic. Because we assume Inline graphic, the test statistic is independent of Inline graphic, and hence is not arrayed over, while Inline graphic ∈ {0.5, 1, Inline graphic}.

Results

In the case when Inline graphic, FPR increases rapidly with correlations that deviate from unity if the proxy-measurement bias, Inline graphic, is large (Fig. 3). Even at moderate to strong correlations (0.4 to 0.7), provided Inline graphic is sufficiently large, the FPR can be ~ 100%. The false positive rate increases with increasing sample size, as the experiment is better powered to detect a false result. Importantly, the false positive rate decreases with increasing Inline graphic, which is expected as the greater noise from the use of the proxy variable drowns out the detected bias.

Fig. 3.

Fig. 3

False positive rate vs correlation across a range of bias values (Inline graphic). Inline graphic, Inline graphic and an array across a typical number of subjects within the neuroimaging literature, Nsamples = 10 (left column), Nsamples = 25 (middle column) and Nsamples = 100 (right column). Values of Inline graphic were 0.5 (top row), 1 (middle row) and 2 (bottom row). At even moderate to strong correlations (0.4 to 0.7), provided Inline graphic is sufficiently large, the false-positive rate can be nearly 100%. The false positive rate increases with increasing sample size, as the experiment is better powered to detect a false result. Similarly, the false positive rate decreases with increasing Inline graphic, as the contaminating signal is drowned out by the contaminating noise.

In the case when Inline graphic, but Inline graphic, even with moderate to strong correlation between gold-standard and proxy measurements, the use of proxy measurements results in a substantial increase in FNR (Fig. 4). For example, with Inline graphic = 25 and Inline graphic the false negative rate can be ~ 7% at Inline graphic, while at a Inline graphic it increases to ~ 33%. As the nominal false-positive rate is increased the measured false positive rate increases, while the false-negative rate decreases (Fig. 5). Thus, while reducing Inline graphic is a viable strategy for reducing the false positive rate, it concomitantly comes with an increase in false negative rate, which may or may not be an acceptable trade-off.

Fig. 4.

Fig. 4

False negative rate vs correlation across a range of differences between gold standard measurements (Inline graphic). Inline graphic, Inline graphic and an array across a typical number of subjects within the neuroimaging literature, Nsamples = 10 (left column), Nsamples = 25 (middle column) and Nsamples = 100 (right column). Values of Inline graphic were not swept as the FNR is independent of it (see Appendix). Even with moderate-to-strong correlations the false negative rate can be substantially inflated. For example, with Nsamples = 25 and Inline graphic at a correlation of 1 the false negative rate is approximately 7%, while at a correlation of 0.7 it’s approximately 33%. The false negative decreases with Inline graphic, as expected, as the experiment is better powered to detect the positive. At low correlations regardless of differences between the true distributions the false negative rate converges to the value of Inline graphic, as expected.

Fig. 5.

Fig. 5

False positive rate (beige) and false negative rate (blue) vs nominal false-positive rate, Inline graphic. The simulations used moderate values of Inline graphic mM, Inline graphic for the false negative rate, and Inline graphic mM for the false positive rate, with Inline graphic mM and N = 25. A strategy to mitigate false positives may appear to decrease Inline graphic, however this comes at an increased false negative rate, which may or may not be equally undesirable.

Using experimental values from the literature19, we demonstrate that the FPR increases dramatically with increasing magnitude of Inline graphic. At the estimated Inline graphic, the FPR ranges from 0.15 (Inline graphic to 1.00 (Inline graphic, as shown in Fig. 6. When Inline graphic is large, the high variance of the contaminant noise drowns out the differential bias, and when VR is small, the large biological variance Inline graphic also drowns out the bias. In other scenarios the differential bias can massively inflate the FPR, with it being as high as ~ 100%, indicating that their purported result should be interpreted with increased caution.

Fig. 6.

Fig. 6

False positive rate versus Inline graphic with experimental values claiming to find a statistically significant difference in GABA/Creatine before and after behavioral training19. The dotted black line indicates the empirically estimated differential bias of Inline graphic. Simulations were performed with values from their study19, specifically Inline graphic, Inline graphic, Inline graphic and Inline graphic. Three sets of Inline graphic and Inline graphic are depicted. The range of VRs is necessary because Inline graphic is estimated, not Inline graphic, and the range of Inline graphic is necessary because the t-statistic is dependent on this value when Inline graphic. Even in the most optimistic scenario (VR = 0.5, Inline graphic), with Inline graphic the false positive rate is inflated to roughly three times its nominal value (15%) and can reach as high as 100% in other scenarios. While this range is large, it demonstrates that correlations alone cannot guarantee statistical validity of tests on proxy variables.

Using values from the literature12, we show that the use of proxy variables can also substantially increase the false negative rate (i.e., reduce statistical power). At the empirical correlation of 0.58 at 3T16, the previously measured Inline graphic results in a FNR of 0.89, 0.83, and 0.79 for VR = 0.5, 1 and 1.3 (Inline graphic), respectively. With a correlation of 1 the FNR is 0.77 and 0.59, for VR = 0.5 and 1, respectively (a correlation of 1 cannot be obtained for Inline graphic), Fig. 7). Thus, this apparent discrepancy between Blicher, et al.12 and Foerster, et al.33 may be explained by the study by Blicher et al. being simply underpowered, or due to the use of short-TE GABA which reduces statistical power.

Fig. 7.

Fig. 7

False negative rate versus Inline graphic using experimental values in a study that disagreed with a previously reported significant difference in GABA/creatine between ALS patients and healthy controls12 for the empirical correlation at 3T (blue) and if the correlation was 1 (orange). Simulations were performed with values from their study, specifically Inline graphic (cases/controls), Inline graphic and Inline graphic. The dotted black line indicates the empirical Inline graphic, obtained from a previous study33. The range of VRs is necessary because Inline graphic is measured, not Inline graphic, while a range of Inline graphic is unnecessary because the t-statistic is independent on this value since Inline graphic. The experimentally measured correlation of 0.58 drastically reduces the statistical power for all 3 VRs displayed here, although it is worth mentioning that for the previously measured Inline graphic, the study is poorly powered even with Inline graphic.

Discussion

This work suggests comprehensively characterizing the relationship between proxy and gold-standard methods is critical for sound inference of experiments using the former. We demonstrated via Monte Carlo simulations that typical correlations found in the literature between short-TE and MEGA-edited GABA do not preclude the possibility of drastically increased false positive and false negative rates. It is important to mention that the assumptions in our model (Appendix) are shown to be consistent with the literature, as they successfully reproduce the moderate correlations often cited as a basis for using short-TE measurements. We have shown across a wide range of parameters (ρ, VR, Inline graphic, N, Δ ,δ) that the use of imperfectly correlated proxy measurements can result in the substantial inflation of false positive and false negative rates. Because these critical parameters are not routinely measured, our goal is to highlight the need to quantify them and to caution against interpreting proxy-based tests as if they were gold-standard results.

It is important to note that while this work focused on the MEGA-edited experiments as the purported gold standard for certain metabolites9, MEGA-edited measurements are themselves a proxy for true concentrations. Thus, this work also has implications for the interpretation of MEGA-edited measurements. Currently, high-quality independent validation measurements of MEGA-edited MRS with other MR or non-MR methods are limited. Selected ex vivo validation of post-mortem tissues have been performed preclinically34 and clinically35. For example, in one animal study, the correlation of short-TE measured GABA with ex vivo concentrations from enzyme-linked immunosorbent assay was 0.66 at 7T34, once again in the range where FPRs and FNRs can be inflated. Statistical advancements on how to best combine proxy and gold-standard measurements are emerging36. Other typical quantified errors do not address the issue investigated here for two important reasons: firstly, and most importantly, we demonstrate that one can be measuring effects (e.g., macromolecules) entirely distinct from the effects one believes they are measuring (GABA), even while maintaining medium-to-high correlations with the desired quantity. Secondly, estimation of uncertainty is invariably difficult in MRS, as typical estimates via the Cramér-Rao Lower Bound require knowledge of the underlying model to fit the experimental data to, which is not known37, and distribution-free uncertainty estimation methods such as Conformal Predictors require access to underlying ground truth examples38,39, which are also inherently unavailable.

To estimate the increase in FPR over the nominal value the differential bias, Inline graphic, must be known. While such values are experimentally unmeasured, the calculation below shows that a small variation in macromolecule concentration, due to their substantially higher amplitudes at short-TEs, could result in values comparable to those used in simulations in this work. GABA has a concentration of approximately 2.1 mM in the healthy brain3,40, and the overlying macromolecules have an absolute proton concentration, Inline graphic, of 19.8 mM at 2.99 ppm, 120.8 mM at 2.04 ppm, and 49.0 mM at 2.26 ppm, which nearly directly overlap with the GABA moieties at 3.01 ppm, 1.89 ppm and 2.23 ppm, respectively. Thus, using the institutional units where GABA/tCr Inline graphic 7.6 from Jia et al.19 (referred to as Inline graphic) and absolute concentration of GABA is Inline graphic mM (referred to as Inline graphic), the institutional concentrations of these three macromolecule resonances would be Inline graphic, where the Inline graphic corrects for Inline graphic being a proton concentration11, and Inline graphic being a molecular concentration (this factor is equal to ½ for all resonances as all moieties of GABA contain 2 protons41) and the last term corrects for the difference in T2 values between GABA and macromolecules at the experimental TE of 36 ms. T2 values of 63 ms were used for GABA (measured at 7T42), and 20.0 ms, 14.3 ms, 19.8 ms, for M2.99, M2.04, M2.26, (measured at 3T11 with similar values obtained at 9.4T43). Thus, Inline graphic, Inline graphic, Inline graphic are 10.5, 31,2, and 25.5 (unitless), respectively. Thus, if even a small change (i.e., a few %) in these macromolecules concentrations between conditions bled into the GABA signal for cases but not controls (or vice versa), it could result in a Inline graphic comparable to the observed value of 1.2 (Fig. 6). While Jia et al.19 used an inversion preparation module to measure the macromolecules, this only partially alleviates the issue as the macromolecule measurement can vary substantially from those in the short-TE spectrum. This is because the inversion preparation module heavily weights the T1 spectrum11. Furthermore, although macromolecules are most problematic due to their poorly characterized spectral shape, there are numerous other directly overlapped metabolites with GABA, such as NAA, NAAG, GSH, glutamate (Glu) and glutamine (Gln) (Fig. 1) which could also potentially bleed into the estimated GABA quantity. While macromolecules are a likely contender for the introduction of such bias, other experimental differences between cases and controls could also cause it. Potential causes include differences in shim quality due to tissue heterogeneity differences44 (e.g., a tumor) or motion differences (which are known to be influenced by conditions such as Alzheimer’s45).

One limitation of the work presented here is the assumption of normality of distributions of the random variables. While this is a common assumption used within the biomedical literature (hence the use of t-tests), there is no inherent physiological reason why such concentrations would be sampled from a normal distribution. We chose the normal distribution as, for a given mean and standard deviation, it maximizes the entropy of the random variables. Hence in the absence of additional information about the distributions it becomes a natural choice. It is also worth mentioning that while the literature simulations focused specifically on GABA/tCr, if GABA and tCr are both sampled from normal distributions and Inline graphic (which has previously been reported as 0.06 at 3T46), then this ratio will also sample from a normal distribution. Work on characterizing the distributions of metabolite concentrations from both healthy and diseased populations would be a valuable contribution and could be used to further refine the results obtained here, among other simulations. Regardless, while the exact numerical results will invariably change based on choice of distributions, the problem investigated here will persist. Importantly, the Jia et al.19 study investigated GABA/tCr, and previous related studies have demonstrated that spurious correlations can arise due to the use of a common denominator47, thus further complicating the interpretation of such results.

Acknowledgements

Special thanks to Dr. Kelley Swanberg for fruitful discussions regarding the material of this work, and Dr. Helge Jörn Zöllner for encouraging its publication. This work was conducted independently and is unrelated to the Karl Landheer’s employment at Regeneron Pharmaceuticals, Inc.

Appendix

Definition of model

1. The True Biological Signal (S): This is the true, unobserved biophysical quantity of interest (e.g., GABA concentration). It is a random variable with a mean Inline graphic and variance Inline graphic.

2. The Gold-Standard Measurement (G): This is the most precise, accurate and/or validated measurement of a quantity of interest (in the context of this work, it is MEGA-edited GABA). We denote Inline graphic and Inline graphic as the gold-standard measurements for the controls and cases in Eqs. 1 and 2. The gold-standard measurement represented by

graphic file with name d33e1367.gif

where Inline graphic is measurement error, assumed to be sampled from a zero-mean normal distribution; Inline graphic and Inline graphic. Note, while gold-standard measurements will inherently possess a constant systematic bias relative to absolute biological truth (i.e., Inline graphic), such a constant cancels out in the calculation of the effect size (Inline graphic, the difference in means) and does not affect the derived false positive or false negative rates, hence was set to 0 here for simplicity. Thus Inline graphic. We make the simplifying assumption that Inline graphic, i.e., the gold-standard measurement variance is dominated by the biological variance. Previous methods have found GABA + /water intra-class correlation Inline graphic 0.8748. From this one can show that Inline graphic. Indicating that Inline graphic is approximately 7 × larger than Inline graphic.

3. The Proxy Measurement (P): This variable represents the measurement obtained from the proxy method (e.g., short-TE GABA), which we denote by Inline graphic and Inline graphic for controls and cases, as in Eqs. 3–4. We model Inline graphic as a weighted sum of the true signal S and an independent contamination/noise component Inline graphic

graphic file with name d33e1445.gif

where Inline graphic is the contaminating signal (e.g., overlapping macromolecules or other metabolites), Inline graphic is the sensitivity coefficient (i.e., how sensitive the proxy measurement is to the true signal, and Inline graphic is the contamination coefficient. Because Inline graphic and Inline graphic are noise terms, we assume S, Inline graphic and Inline graphic are all mutually independent.

Derivation of proxy variance and correlation

The variance of the proxy variable can be obtained from its definition

graphic file with name d33e1482.gif

The correlation between the gold-standard and proxy variable is

graphic file with name d33e1487.gif

The covariance term can be expressed as Inline graphic, which rests on the mutual independence assumption of S, Inline graphic and Inline graphic and the bilinearity of covariance. Thus, the correlation becomes

graphic file with name d33e1504.gif

where we have defined Inline graphic, and the approximation arises due to the assumption of Inline graphic. We then define the variance ratio, VR, as

graphic file with name d33e1517.gif

Combining the above two expressions we obtain Inline graphic. Since we assume Inline graphic (as Inline graphic would imply the proxy variable is more sensitive to the true signal than the gold standard), we note that the VR provides an upper bound for the attainable correlation, i.e., Inline graphic Also, from these expressions it can be shown that Inline graphic and Inline graphic

Derivation of expectation values

The expectation value for the gold-standard control group is

graphic file with name d33e1553.gif

And similarly, the expectation value for the gold-standard case group is

graphic file with name d33e1558.gif

where Inline graphic is the true desired effect size (i.e., Inline graphic). The expectation value for the proxy control group can be expressed as

graphic file with name d33e1570.gif

And similarly, the expectation value for the proxy case group can be expressed as

graphic file with name d33e1575.gif

Derivation of t-statistic

The t-statistic for a two-sample Welch’s t-test is the ratio of the true difference in means to the standard error of that difference:

graphic file with name d33e1582.gif

where Inline graphic and Inline graphic are the sample sizes of the control and case groups, respectively. Given that Inline graphic and that Inline graphic and that Inline graphic this becomes

graphic file with name d33e1607.gif

which is independent of parameters Inline graphic (introduction of bias in both cases and controls from use of proxy variable) and Inline graphic (the true mean of the biological signal). Furthermore, if we assume Inline graphic is a known constant then the t-statistic is independent of VR and independent of Inline graphic when Inline graphic = 0, but proportional to Inline graphic if Inline graphic. In the fixed Inline graphic scenario the only effect VR has on these simulations is that it determines the upper bound for correlation, Inline graphic if Inline graphic. For this reason, we set VR = 1 for the theoretical simulations, as the purpose of this is to investigate the question of given a fixed biological signal, how does the use of proxy measurements distort the statistical results. Alternatively, we can express the t-statistic as

graphic file with name d33e1653.gif

which is proportional to Inline graphic. Thus, if t is parameterized by Inline graphic it is dependent on VR. In the literature simulations we choose this form, as Inline graphic is measured.

Author contributions

MT, CJ, KL wrote the main manuscript, MT and KL prepared main figures, MT and KL devised and carried out all simulations, and KL and CJ conceptualized the project. All authors reviewed the manuscript.

Funding

Not applicable.

Data availability

The code to generate all data and reproduce all results is available at: github.com/karllandheer/GoldStandardVsProxy.

Declarations

Competing interests

KL is an employee and shareholder of Regeneron Pharmaceuticals, Inc, and a shareholder of Vertex Pharmaceuticals. Other authors declare no conflict of interest.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Bottomley, P. A. Spatial localization in NMR spectroscopy in vivo. Ann. N. Y. Acad. Sci.508, 333–348 (1987). [DOI] [PubMed] [Google Scholar]
  • 2.Haase, A. et al. MR imaging using stimulated echoes (STEAM). Radiology160, 787–790 (1986). [DOI] [PubMed] [Google Scholar]
  • 3.Landheer, K., Gajdošík, M. & Juchem, C. A semi-LASER, single-voxel spectroscopic sequence with a minimal echo time of 20.1 ms in the human brain at 3 T. NMR Biomed.33, e4324 (2020). [DOI] [PubMed] [Google Scholar]
  • 4.Deelchand, D. K. et al. Across-vendor standardization of semi-LASER for single-voxel MRS at 3T. NMR Biomed.34, e4218 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Landheer, K., Schulte, R. F., Treacy, M. S., Swanberg, K. M. & Juchem, C. Theoretical description of modern 1H in Vivo magnetic resonance spectroscopic pulse sequences. J. Magn. Reson. Imag.51, 1008–1029 (2020). [DOI] [PubMed] [Google Scholar]
  • 6.Mescher, M., Tannus, A., Johnson, M. O. & Garwood, M. Solvent suppression using selective echo dephasing. J. Magn. Reson. Ser. A123, 226–229 (1996). [Google Scholar]
  • 7.Rothman, D. L., Petroff, O. A. C., Kevin, L. & Mattson, R. H. Localized 1H NMR measurements of y-aminobutyric acid in human brain in vivo. Proc. Natl. Acad. Sci. USA90, 5662–5666 (1993). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Near, J., Evans, C. J., Puts, N. A. J., Barker, P. B. & Edden, R. A. E. J-difference editing of GABA: simulated and experimental multiplet patterns. Magn Reson Med70, 1183–1191 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Choi, I. Y. et al. Spectral editing in 1H magnetic resonance spectroscopy: experts’ consensus recommendations. NMR Biomed.34, 1–30 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Peek, A. L. et al. A comprehensive guide to MEGA-PRESS for GABA measurement. Anal. Biochem.669, 115113 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Landheer, K., Gajdosik, M., Treacy, M. & Juchem, C. Concentration and T2 relaxation times of macromolecules at 3 tesla. Magn. Reson. Med.84, 2327–2337 (2020). [DOI] [PubMed] [Google Scholar]
  • 12.Blicher, J. U. et al. Short echo-time magnetic resonance spectroscopy in ALS, simultaneous quantification of glutamate and GABA at 3 T. Sci. Rep.9, 1–7 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Collée, M. et al. Predicting performance in attention by measuring key metabolites in the PCC with 7T MRS. Sci. Rep.14, 17099 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Jurkovičová, L. et al. Subjective visual sensitivity in neurotypical adults: Insights from a magnetic resonance spectroscopy study. Front. Neursci.18, 1–16 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Mekle, R. et al. Detection of metabolite changes in response to a varying visual stimulation paradigm using short-TE 1H MRS at 7 T. NMR Biomed.30, 1–9 (2017). [DOI] [PubMed] [Google Scholar]
  • 16.Near, J. et al. Unedited in vivo detection and quantification of γ-aminobutyric acid in the occipital cortex using short-TE MRS at 3T. NMR Biomed.26, 1353–1362 (2013). [DOI] [PubMed] [Google Scholar]
  • 17.Prinsen, H., de Graaf, R. A., Mason, G. F., Pelletier, D. & Juchem, C. Reproducibility measurement of glutathione, GABA, and glutamate: Towards in vivo neurochemical profiling of multiple sclerosis with MR spectroscopy at 7T. J. Magn. Reson. Imag.45, 187–198 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Younis, S. et al. Feasibility of glutamate and GABA detection in pons and thalamus at 3T and 7T by proton magnetic resonance spectroscopy. Front. Neurosci.14, 1–12 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Jia, K. et al. Recurrent inhibition refines mental templates to optimize perceptual decisions. Sci. Adv.10, eado7378 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Nettekoven, C. et al. Cerebellar GABA change during visuomotor adaptation relates to adaptation performance and cerebellar network connectivity: A magnetic resonance spectroscopic imaging study. J. Neurosci.42, 7721–7732 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Biria, M. et al. Cortical glutamate and GABA are related to compulsive behaviour in individuals with obsessive compulsive disorder and healthy controls. Nat. Commun.14, 3324 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Frangou, P. et al. Learning to optimize perceptual decisions through suppressive interactions in the human brain. Nat. Commun.10, 1–12 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Deelchand, D. K., Marjańska, M., Hodges, J. S. & Terpstra, M. Sensitivity and specificity of human brain glutathione concentrations measured using short-TE 1H MRS at 7 T. NMR Biomed.29, 600–606 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Schubert, F., Kühn, S., Gallinat, J., Mekle, R. & Ittermann, B. Towards a neurochemical profile of the amygdala using short-TE 1H magnetic resonance spectroscopy at 3 T. NMR Biomed.30, 1–10 (2017). [DOI] [PubMed] [Google Scholar]
  • 25.Crisi, G., Filice, S., Michiara, M., Crafa, P. & Lana, S. 2-Hydroxyglutarate detection by short echo time magnetic resonance spectroscopy in routine imaging study of brain glioma at 3.0 T. J. Comput. Assist. Tomogr.42, 469–474 (2018). [DOI] [PubMed] [Google Scholar]
  • 26.Natsumeda, M. et al. Accumulation of 2-hydroxyglutarate in gliomas correlates with survival: A study by 3.0-tesla magnetic resonance spectroscopy. Acta Neuropathol. Commun.2, 1–7 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Natsumeda, M. et al. Reliable diagnosis of IDH-mutant glioblastoma by 2-hydroxyglutarate detection: A study by 3-T magnetic resonance spectroscopy. Neurosurg. Rev.41, 641–647 (2018). [DOI] [PubMed] [Google Scholar]
  • 28.Begley, C. G. & Ellis, L. M. Raising standards for preclinical research. Nature483, 531–533 (2012). [DOI] [PubMed] [Google Scholar]
  • 29.Ioannidis, J. P. A. Why most published research findings are false. PLoS Med.2, e214 (2005). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Landheer, K., Treacy, M. & Juchem, C. The consequences of statistical tests on proxy variables, an application to short-TE as an estimation for MEGA-edited GABA. In Proceedings of the International Society for Magnetic Resonance in Medicine 5241 (2025).
  • 31.Landheer, K., Prinsen, H., Petroff, O. A., Rothman, D. L. & Juchem, C. Elevated homocarnosine and GABA in subject on isoniazid as assessed through 1H MRS at 7T. Anal. Biochem.599, 113738 (2020). [DOI] [PubMed] [Google Scholar]
  • 32.Lim, S. I. & Xin, L. γ-aminobutyric acid measurement in the human brain at 7 T: Short echo-time or Mescher-Garwood editing. NMR Biomed.35, 1–17 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Foerster, B. R. et al. Decreased motor cortex γ-aminobutyric acid in amyotrophic lateral sclerosis. Neurology78, 1596–1600 (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Janik, R. et al. Magnetic resonance spectroscopy reveals oral Lactobacillus promotion of increases in brain GABA, N-acetyl aspartate and glutamate. Neuroimage125, 988–995 (2016). [DOI] [PubMed] [Google Scholar]
  • 35.Rothman, D. L., Behar, K. L., Petroff, O. A. C. & Shulman, R. G. The early days of ex vivo 1H, 13C, and 31P nuclear magnetic resonance in the laboratory of Dr. Robert G. Shulman from 1975 to 1995. NMR Biomed.36, 1–12 (2023). [DOI] [PubMed] [Google Scholar]
  • 36.Miao, J., Miao, X., Wu, Y., Zhao, J. & Lu, Q. Assumption-lean and data-adaptive post-prediction inference. J. Mach. Learn. Res.26, 1–31 (2025). [Google Scholar]
  • 37.Landheer, K. & Juchem, C. Are Cramér-Rao lower bounds an accurate estimate for standard deviations in in vivo magnetic resonance spectroscopy?. NMR Biomed.34, e4521 (2021). [DOI] [PubMed] [Google Scholar]
  • 38.Shafer, G. & Vovk, V. A tutorial on conformal prediction. J. Mach. Learn. Res.9, 371–421 (2008). [Google Scholar]
  • 39.Angelopoulos, A. N. & Bates, S. A Gentle introduction to conformal prediction and distribution-free uncertainty quantification (2021).
  • 40.de Graaf, R. A. In Vivo NMR spectroscopy—2nd edition: Principles and techniques (Wiley, 2007).
  • 41.Govindaraju, V., Young, K. & Maudsley, A. A. Proton NMR chemical shifts and coupling constants for brain metabolites. NMR Biomed.13, 129–153 (2000). [DOI] [PubMed] [Google Scholar]
  • 42.Intrapiromkul, J., Zhu, H., Cheng, Y., Barker, P. B. & Edden, R. A. E. Determining the in vivo transverse relaxation time of GABA in the human brain at 7T. J. Magn. Reson. Imaging38, 1224–1229 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Murali-Manohar, S., Wright, A. M., Borbath, T. & Henning, A. T2 relaxation times of macromolecules and metabolites in the human brain at 9.4 T. Magn. Reson. Med.10.1002/mrm.28174 (2020). [DOI] [PubMed] [Google Scholar]
  • 44.Juchem, C. et al. B0 shimming for in vivo magnetic resonance spectroscopy: Experts’ consensus recommendations. NMR Biomed.10.1002/nbm.4350 (2020). [DOI] [PubMed] [Google Scholar]
  • 45.Haller, S. et al. Head motion parameters in fMRI differ between patients with mild cognitive impairment and Alzheimer disease versus elderly control subjects. Brain Topogr.27, 801–807 (2014). [DOI] [PubMed] [Google Scholar]
  • 46.Gasparovic, C. et al. Test-retest reliability and reproducibility of short-echo-time spectroscopic imaging of human brain at 3T. Magn. Reson. Med.66, 324–332 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Hong, S., Tomar, J. S. & Shen, J. Metabolic coupling between glutamate and N-acetylaspartate in the human brain. JCBFM44, 1608–1617 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Duda, J. M. et al. Repeatability and reliability of GABA measurements with magnetic resonance spectroscopy in healthy young adults. Magn. Reson. Med.85, 2359–2369 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Landheer, K., Swanberg, K. M. & Juchem, C. Magnetic resonance Spectrum simulator (MARSS), a novel software package for fast and computationally efficient basis set simulation. NMR Biomed.10.1002/nbm.4129 (2019). [DOI] [PubMed] [Google Scholar]
  • 50.Landheer, K. et al. synMARSS—An end-to-end platform for the parametric generation of synthetic in vivo magnetic resonance spectra. NMR Biomed.38, e70013 (2025). [DOI] [PubMed] [Google Scholar]