Skip to main content
Springer logoLink to Springer
. 2025 Oct 6;44(1):217–223. doi: 10.1007/s11419-025-00740-5

Evaluation of blood impurity removal efficiency using the QuEChERS method

Haruki Kuze 1, Haruhi Yoshida 1, Hikaru Tamagawa 1, Taichi Nishihori 1, Yuri Tokugawa 1, Fumika Yamamoto 1, Hiroshi Matsumoto 2,3, Kazuo Harada 1,2,
PMCID: PMC12858495  PMID: 41051724

Abstract

Purpose

Comparison of the impurity removal efficiencies of the deproteinization and Quick, Easy, Cheap, Effective, Rugged, Safe (QuEChERS) methods, which are pretreatment methods for drug analysis adopted by many forensic autopsy institutions, was performed.

Method

Residual cardiac blood samples were pretreated using deproteinization and QuEChERS methods. The residual amounts of total proteins, total lipids, glucose, galactose, electrolytes, and inorganic elements were measured. We also compared the recovery rates and matrix factors when using liquid chromatography/tandem mass spectrometry (LC/MS/MS).

Results

The residual rates of total proteins, total lipids, glucose, galactose, and electrolytes using the deproteinization method were 16%, 75%, 75%, 90%, and 91%, respectively. In contrast, the QuEChERS method showed 1.1%, 11%, 7.6%, 9.4%, and 20%, respectively. The amounts of Mg and Mn in QuEChERS increased compared with those before treatment, but other inorganic elements remained at 9.6–89% during deproteinization and 0.30–17% in the QuEChERS. The recovery rate of metformin was low in QuEChERS; however, no differences were observed in the recovery rates or matrix factors of the other 16 drugs between deproteinization and QuEChERS.

Conclusions

This study quantitatively demonstrated that QuEChERS is extremely efficient at removing impurities from blood compared with deproteinization methods. QuEChERS has poor recovery rates for highly polar drugs but does not prevent their detection. The QuEChERS method is superior to the deproteinization method, considering the load of impurities on the analytical instruments.

Supplementary Information

The online version contains supplementary material available at 10.1007/s11419-025-00740-5.

Keywords: Impurity, Deproteinization, QuEChERS, Recovery rate, Matrix factor

Introduction

Gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), which have excellent specificity and sensitivity, are commonly used for drug analysis in forensic autopsies [19]. If a biological sample, such as blood, is directly injected into these analyses, impurities such as proteins, lipids, carbohydrates, and metals contained in the sample can damage the instruments, reduce their sensitivity, and cause fluctuations in the quantitative values due to matrix effects [1013]. To prevent these problems, it is necessary to remove impurities from the sample. The methods used for drug analysis in forensic autopsies include liquid–liquid partitioning using non-polar organic solvents, solid-phase extraction using mini-columns, deproteinization using water-soluble organic solvents, and the Quick, Easy, Cheap, Effective, Rugged, Safe (QuEChERS) method, which uses MgSO4 to separate acetonitrile and water and allows for liquid–liquid partitioning. These methods may also be combined with dispersive solid-phase extraction, in which particles surface-modified with octadecyl silyl (C18) or primary-secondary amine are added to the extraction solution. Taking into consideration the comprehensiveness of the drugs to be detected, throughput, and other institutional factors, we considered deproteinization and QuEChERS to be appropriate pre-treatment methods [1416]. However, the impurity removal rates of these pretreatment methods have not been quantitatively evaluated. Therefore, we compared the impurity removal efficiency in blood samples between the deproteinization and QuEChERS methods and further validated the QuEChERS method.

Materials and methods

Reagents

LC/MS-grade ultrapure water, methanol, and acetonitrile were purchased from FUJIFILM Wako Pure Chemical Corporation (Osaka, Japan). Methoxyamine hydrochloride and N-methyl-(N-trimethylsilyl) trifluoroacetamide for the derivatization of glucose and galactose were purchased from Sigma-Aldrich (Merck KGaA, Darmstadt, Germany) and GL Sciences (Tokyo, Japan), respectively. The standard chemicals used for validation were purchased from FUJIFILM Wako Pure Chemical Corporation and Sigma-Aldrich, and 1 mg/mL methanol solutions were prepared as stock solutions and diluted appropriately.

Sample preparation

The samples were obtained from the right heart blood samples from the Department of Legal Medicine, Osaka University, where no drugs were detected. To evaluate the individual differences in impurities, matrix factors, and recovery rates, each individual sample was used without mixing. For deproteinization, 450 μL of ultrapure water was added to 50 μL of sample, followed by 500 μL of acetonitrile. After vortexing and centrifuging at 10,000 × g for 3 min, supernatants were collected. The supernatant was dried using a centrifugal concentrator, and the residue was dissolved in 50 μL of ultrapure water. For the QuEChERS method, a kit Q-Sep Q251 manufactured by RESTEK (Bellefonte, PA, USA), in which MgSO4, C18, and primary-secondary amines were pre-aliquoted in tubes, was used. The sample (50 μL) was added to the tube, followed by 450 μL of ultrapure water, 500 μL of acetonitrile, and a 4-mm stainless steel bead. After vortexing and centrifuging at 10,000 × g for 3 min, supernatants were collected. The supernatant was dried using a centrifugal concentrator (CVE-3110, TOKYO RIKAKIKAI CO., LTD., Tokyo, Japan), and the residue was dissolved in 50 μL of ultrapure water. To analyze the impurity removal rate, in addition to the samples prepared using deproteinization and QuEChERS methods as described above, 50 μL of untreated blood was used as a reference.

Total protein and total lipid measurement

The total protein and lipid contents in the samples were quantified using the Fuji Dry Chem slide, TP-PIII, and TG-PIII (provided by FUJIFILM) on a Fuji Dry Chem (7000 V, FUJIFILM) system.

Electrolyte and metal element measurement

To measure the electrolytes, 50 μL of the sample solution was diluted with 950 μL of ultrapure water and measured using a portable conductivity meter (LAQUAtwin-EC-33, HORIBA, Kyoto, Japan).

Metal elements were analyzed as described by Cesbron et al. [17]. The sample solution (50 μL) was diluted with 4.95 mL of a solution containing 1% (v/v) nitric acid, 0.5% (v/v) 1-butanol, 0.1% (w/v) Triton X-100, and 1 mg/L gallium, and subjected to inductively coupled plasma-mass spectrometry (ICP-MS). An Agilent 7700x instrument (Agilent Technologies, Santa Clara, CA, USA) was used for the ICP-MS measurements. The RF power was set to 1550 W. Argon and helium were used as the carrier and collision gases, respectively. The carrier gas was 1.05 L/min. The m/z scan ranges were 2–15, 20–39, and 42–260. The integration time was 0.1 s for each peak point and 0.6 s for each mass number. Tuning was conducted by tuning the mix containing 1 μg/L Li, Co, Y, Ce, and Tl in 5% nitric acid (Agilent Technologies) immediately before measuring the samples.

GC/MS for glucose and galactose measurements

GC/MS for glucose and galactose measurements was modified from the method described by Chan et al. [18]. The blood sample (50 μL) was transferred to a 1.5 mL microtube, and 13 μL of 1 mM ribitol in methanol was added as an internal standard. Subsequently, 300 μL of methanol was added, and the mixture was vortexed for 15 s. After centrifugation at 15,000 × g for 15 min, 250 μL of the supernatant was transferred to a 2.0 mL Eppendorf microtube and dried overnight using a centrifugal concentrator. A total of 50 μL of 1 mg/mL methoxyamine in pyridine was added to the dry residue, and methoxylation was performed using a ThermoMixer (Eppendorf, Hamburg, Germany) by shaking at 80 °C for 15 min at 1200 rpm. After adding 50 μL of N-methyl-N-(trimethylsilyl)trifluoroacetamide was performed in ThermoMixer by shaking at 80 °C for 15 min at 1200 rpm. After cooling for 5 min, the sample was centrifuged at 15,000 × g for 15 min, and 100 μL of the supernatant was transferred into sample vials for GC/MS. GC/MS was performed using a GCMS-QP2010 SE instrument (Shimadzu Corp., Kyoto, Japan). The autosampler was an AOC-20i/s (Shimadzu Corp.), and the column was a GC column BPX5 (0.25 mm i.d. × 30 m, 0.25 μm thick, Trajan, Melbourne, Australia). Helium was used as the carrier gas, and the flow rate was controlled to maintain the column linear velocity at 39.0 cm/s. The splitting ratio was 1:30. The sample injection volume was 1 μL. The temperature of the vaporization chamber was set to 250 °C. The temperature of the column oven was held at 60 °C for 2 min, raised to 330 °C at a rate of 15 °C/min, and held there for 3.34 min. Sample ionization was performed using the electron ionization method. The temperature at the ion source was set at 200 °C, and that at the interface section was set at 280 °C. The detector voltage was tuned 3 min after sample injection, and the scan data were collected from 3.5 to 23.14 min. The scan time was 0.20 s. The detector voltage was set at + 0.1 kV from the tuning value, and the scan range was set to m/z 45–600.

LC/MS

LC/MS was performed using an LCMS8060 instrument (Shimadzu Corp.). LC separations were conducted at 40 °C with a Kinetex XB-C18 (2.6 μm, 2.1 mm i.d. × 100 mm, Phenomenex, Torrance, CA, USA). The mobile phase was delivered at a flow rate of 0.3 mL/min using a gradient elution profile consisting of Solvent A (0.1% formic acid and 10 mmol/L ammonium formate in distilled water) and Solvent B (0.1% formic acid and 10 mmol/L ammonium formate in methanol). The initial composition of the binary solvent was 5% Solvent B, which was increased to 95% at 7.5 min. The composition of Solvent B was maintained at 95% for 2.5 min. The injection volume was 5 μL. The mass spectrometer was operated with a DUIS™ source in positive ion mode and set in the multiple reaction monitoring (MRM) mode. Nebulizer, heating, and drying gas flows were set to 2, 10, 10 L/min, respectively, whereas interface, desolvation line, and heat block temperatures were set at, 300, 250, and 400 °C, respectively. The dwell time for each MRM transition was set to 2 ms. The MRM transitions are shown in Supplemental Table 1.

Validation

Blood samples were prepared using deproteinization or the QuEChERS method, followed by LC/MS measurements. Based on the calibration curve obtained using a dilution series by preparing the standard stock solution with ultrapure water and methanol, concentration value A was obtained by adding the standard chemicals to the blood samples before pretreatment, and concentration value B was obtained by adding standard chemicals to the blood samples after pretreatment. The matrix factor (MF) value was calculated as the ratio of B/(added concentration), and the recovery rate was calculated as A/B × 100(%). With the exception of etizolam and temazepam, the added concentration was 1000 ng/mL. Because the signals for etizolam and temazepam were saturated at 1000 ng/mL, these were evaluated at 316 ng/mL.

The accuracy and precision of the QuEChERS method were evaluated. Standard chemicals were added to the blood at four concentrations: near the lower limit of quantification, low, medium, and high concentrations, in the concentration range of 1–1000 ng/mL. Measurements were repeated five times on each analysis day over three days, and intraday and interday variations were calculated. Accuracy value was defined as the degree of agreement between the average of the measured concentrations of 15 times and the concentration of the standard solution added. As internal standards, stable isotope-labeled compounds 7-aminoflunitrazepam-d7, acetaminophen-d3, alprazolam-d5, diazepam-d5, etizolam-d3, metformin-d6, and zolpidem-d7 were used for each non-label compound measurement. For other chemicals, diazepam-d5 was used as an internal standard.

Results

Impurity removal rate of deproteinization and QuEChERS methods

Right heart blood samples obtained from six cadavers were treated using deproteinization and QuEChERS methods, and the residual amounts of contaminants, including total proteins, total lipids, glucose, galactose, and electrolytes, were measured (Fig. 1). The remaining total proteins, relative to the amount contained in the blood before pretreatment, was 16% using the deproteinization method and 1.1% using the QuEChERS method (Fig. 1a). The residual rates of total lipids, glucose, galactose, and electrolytes using the deproteinization method were 75%, 75%, 90%, and 91%, respectively. In contrast, the QuEChERS method showed 11%, 7.6%, 9.4%, and 20%, respectively (Fig. 1b–e). Metal element measurements by ICP-MS showed that the residual rates of sodium, potassium, phosphorus, and chlorine were significantly lower using the QuEChERS method than using the deproteinization method (Fig. 1f). Magnesium and manganese increased with QuEChERS compared with the sample before pretreatment (Fig. 1g).

Fig. 1.

Fig. 1

Residual amounts of contaminants in cardiac blood samples after deproteinization (Dep) and QuEChERS (QuE) treatment. sThe contaminants analyzed were a total proteins, b total lipids, c glucose, d galactose, e electrolyte, and f, g inorganic elements. The values are shown as relative values, with the content of each contaminant in the untreated blood sample considered 100%. Blood samples were obtained from six cadavers. Bars and error bars represent means and standard deviations, respectively

Recovery and MF of deproteinization and QuEChERS methods

The recovery rates and MF values of 17 drugs obtained using the deproteinization and QuEChERS methods are shown in Table 1. The selection of these drugs was based on their relatively high frequency of detection in our laboratory and the fact that we had standard substances of these drugs. The concentration of the analytes was set to 316–1000 ng/mL, which is the upper limit of quantification at which carryover and saturation do not occur. The recovery rate of all compounds was higher using the deproteinization method. In particular, metformin showed a large difference, with 110% with deproteinization and 36% with QuEChERS. In contrast, the MF values were similar for both methods, and no differences were observed.

Table 1.

Recovery and matrix factor of deproteinization and QuEChERS

Recovery (%) Matrix factor (%)
Deproteinized QuEChERS Deproteinized QuEChERS
7-aminoflunitrazepam 102 ± 13 78 ± 5 92 ± 14 100 ± 19
Acetaminophen 96 ± 10 82 ± 8 105 ± 22 96 ± 30
Alprazolam 103 ± 15 74 ± 5 92 ± 11 84 ± 45
Diazepam 103 ± 15 74 ± 5 93 ± 15 101 ± 22
Ephedrine 98 ± 11 65 ± 3 92 ± 15 96 ± 19
Etizolam 103 ± 16 67 ± 5 81 ± 11 104 ± 21
Flunitrazepam 106 ± 16 77 ± 5 87 ± 12 91 ± 21
Lacosamide 101 ± 14 82 ± 5 96 ± 13 97 ± 17
Metformin 111 ± 9 37 ± 10 13 ± 5 13 ± 4
Methylphenidate 101 ± 15 63 ± 4 97 ± 14 105 ± 17
Mirtazapine 105 ± 16 45 ± 2 92 ± 14 103 ± 20
Nifedipine 104 ± 17 77 ± 5 98 ± 16 122 ± 22
Sulpiride 99 ± 13 72 ± 6 104 ± 15 114 ± 16
Temazepam 102 ± 15 64 ± 3 98 ± 11 98 ± 21
Trazodone 101 ± 16 65 ± 4 97 ± 14 102 ± 21
Warfarin 99 ± 13 78 ± 5 109 ± 17 108 ± 14
Zolpidem 102 ± 16 69 ± 4 98 ± 14 105 ± 21

The values are means ± standard deviation obtained using right heart blood samples from six individuals. The added concentration was 1000 ng/mL except for etizolam and temazepam. Because the signals for etizolam and temazepam were saturated at 1000 ng/mL, they were evaluated at 316 ng/mL

Precision and accuracy of the QuEChERS method

The results of the evaluation of the precision and accuracy of 17 drugs are shown in Table 2. The intraday and interday variations were 3–31% and 5–32%, respectively. The accuracy values ranged from 86 to 140%. However, for many items, the intraday and interday variations were less than 15% (20% at the limit of quantitation (LOQ)), and the accuracy values were within the range of 100 ± 15% (100 ± 20% at LOQ).

Table 2.

Precision and accuracy of the QuEChERS method

Conc. (ng/mL) Intraday precision (RSD%) Interday precision (RSD%) Accuracy (%)
LOQ Low Middle High LOQ Low Middle High LOQ Low Middle High LOQ Low Middle High
7-Aminoflunitrazepam* 3.2 10 100 1000 14 9 3 7 15 13 6 9 98 98 96 97
Acetaminophen* 32 100 316 1000 23 8 7 11 25 11 8 12 97 94 94 93
Alprazolam* 1.0 3.2 32 1000 22 14 6 8 23 16 10 8 97 96 98 96
Diazepam* 1.0 3.2 32 1000 22 12 11 11 32 12 14 12 108 105 98 97
Ephedrine 3.2 10 32 1000 17 10 7 12 18 16 10 16 114 100 94 105
Etizolam* 3.2 10 32 316 12 12 8 4 13 17 9 5 100 115 112 89
Flunitrazepam 1.0 10 100 1000 15 14 10 11 20 17 11 13 93 98 96 98
Lacosamide 1.0 3.2 100 1000 17 12 5 11 18 12 6 15 103 99 96 100
Metformin 10 32 100 1000 11 8 4 10 20 12 5 11 99 96 95 94
Methylphenidate 1.0 3.2 100 1000 9 9 7 13 15 10 12 14 121 102 94 107
Mirtazapine 1.0 3.2 100 1000 12 14 9 14 14 14 14 14 140 111 95 93
Nifedipine 3.2 10 100 1000 22 10 9 12 23 12 10 14 113 101 100 102
Sulpiride 1.0 3.2 100 1000 12 10 13 16 12 10 14 18 126 102 86 99
Temazepam 1.0 3.2 10 316 20 14 10 6 25 18 13 7 97 113 115 101
Trazodone 1.0 3.2 100 1000 16 10 5 11 17 12 10 13 121 104 93 98
Warfarin 1.0 3.2 100 1000 25 17 5 12 28 18 9 14 87 87 99 94
Zolpidem* 1.0 3.2 100 1000 31 15 3 8 32 16 9 9 99 94 95 96

The standard chemicals were added to the blood at four concentrations: near the lower limit of quantification (LOQ), and low, medium, and high concentrations, in the concentration range of 1–1000 ng/mL. Measurements were repeated five times on each analysis day over three days, and intraday and interday variations were calculated. Accuracy value was defined as the degree of agreement between the average of the measured concentrations of a total of 15 times and the concentration of the standard solution added

*: Stable isotope-labeled compounds were used as internal standards. For other chemicals, diazepam-d5 was used as an internal standard

Discussion

Proteins, lipids, carbohydrates, and metal elements contained in biological samples are impurities in GC/MS and LC/MS measurements. These impurities lead to clogging of the mobile phase flow line, ionization probe, and ion inlet, reduction in column resolution due to adsorption, and decrease in detection sensitivity due to ionization suppression [1013, 19, 20]. For all these impurities, the residual amount in the sample was lower with the QuEChERS method than with the deproteinization method, indicating a higher removal efficiency. Although approximately 85% of the total proteins was removed using the deproteinization method, only approximately 99% was removed using the QuEChERS method. Although only approximately 10–32% of lipids, glucose, galactose, and electrolytes were removed using the deproteinization method, approximately 80–92% were removed using the QuEChERS method, showing a large difference in removal efficiency. When the residual amounts of each metal element in the sample were evaluated, the amounts of Mg and Mn were higher in the QuEChERS method than in the deproteinization method. This was thought to be largely due to the influence of MgSO4 and the adsorbents included in the QuEChERS kit. However, as mentioned above, the total amount of electrolytes was more efficiently removed by the QuEChERS method than by the deproteinization method, and the increase in Mg and Mn was much smaller than the decrease in the total amount of electrolytes. The data presented in this study, which quantitatively evaluate the impurity removal rate by pretreatment, are extremely valuable.

Although when using the two methods, we obtained a similar MF value, which influences quantification, recovery rates tended to be higher when using the deproteinization method. Notably, there was a particularly large difference between the deproteinization and QuEChERS methods with respect to the rate at which metformin was recovered. Metformin has an extremely high water solubility, with an octanol/water partition ratio (LogPow) of −2.64 (Supplemental Table 1), and should accordingly be predominantly distributed in the aqueous layer, even when using the QuEChERS method. Furthermore, as blood impurities, carbohydrates and electrolytes should similarly be distributed within the aqueous layer when using QuEChERS. Consequently, a high correlation between the recovery of metformin and the residual fractions of carbohydrates and electrolytes was anticipated, which was indeed the result obtained. Contrastingly, the LogPow values obtained for the other assessed compounds were all greater than 0, implying a predominant distribution in the acetonitrile layer. Indeed, using QuEChERS method, with the exception of mirtazapine, for which we obtained a recovery of approximately 50%. The rates at which all the other assessed compound were recovered exceeded 50%. Notably, these recoveries did not appear to be substantially influenced by the removal of impurities. In addition, a low rate of recovery indicates that a target compound may have been overlooked at low concentrations. Thus, deproteinization was superior to QuEChERS in terms of the comprehensiveness of detection. However, by selecting appropriate internal standards for analytes with low recovery rates, the QuEChERS method achieved good results from the perspectives of accuracy and precision.

In this study, no correlation was found between the removal efficiency of the contaminants and the MF values or analyte recovery rates. However, there is no doubt that the deproteinization method left more impurities, which were then introduced into the LC/MS device. This suggests that the degree of equipment contamination may progress more rapidly with deproteinization, leading to more frequent maintenance. Since adopting this method, we have been performing analyses at a rate of 100 to 200 injections per month over the past 2 years, during which time the frequency of mechanical problems in the Department of Legal Medicine has been substantially reduced, and no maintenance of the mass spectrometer has been required.

Conclusions

This is the first study to compare the impurity removal efficiencies of pretreatment methods for drug analysis in legal autopsies. The QuEChERS method removed more impurities than the deproteinization method. Considering that drug analysis will be conducted over the long term, the QuEChERS method may be superior because such impurities accumulate on the analytical equipment.

Supplementary Information

Below is the link to the electronic supplementary material.

Acknowledgements

We thank Editage (www.editage.com) for English language editing.

Author contributions

Conceptualization: Kazuo Harada; data collection: Haruki Kuze, Haruhi Yoshida, Hikaru Tamagawa, Taichi Nishihori, Yuri Tokugawa, and Fumika Yamamoto; statistical analysis: Haruki Kuze and Kazuo Harada; writing-original draft preparation: Haruki Kuze and Kazuo Harada; writing-review and editing: Hiroshi Matsumoto and Kazuo Harada.

Funding

Open Access funding provided by The University of Osaka.

Data availability

The datasets generated during the current study are available from the corresponding author upon reasonable request.

Declarations

Conflict of interest

There are no conflicts of interest to declare.

Ethical approval

This study was approved by the Ethics Committees of The University of Osaka Hospital (no. 23017). All experiments were performed in accordance with the ethical standards of the institutional research.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Drummer OH (1999) Chromatographic screening techniques in systematic toxicological analysis. J Chromatogr B 733(1–2):27–45. 10.1016/s0378-4347(99)00265-0 [DOI] [PubMed] [Google Scholar]
  • 2.Bogusz MJ (2000) Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity. J Chromatogr B 748(1):3–19. 10.1016/s0378-4347(00)00461-8 [DOI] [PubMed] [Google Scholar]
  • 3.Saint-Marcoux F, Lachâtre G, Marquet P (2003) Evaluation of an improved general unknown screening procedure using liquid chromatography-electrospray-mass spectrometry by comparison with gas chromatography and high-performance liquid-chromatography—diode array detection. J Am Soc Mass Spectrom 14(1):14–22. 10.1016/S1044-0305(02)00801-2 [DOI] [PubMed] [Google Scholar]
  • 4.Herrin GL, McCurdy HH, Wall WH (2005) Investigation of an LC-MS-MS (QTrap) method for the rapid screening and identification of drugs in postmortem toxicology whole blood samples. J Anal Toxicol 29(7):599–606. 10.1093/jat/29.7.599 [DOI] [PubMed] [Google Scholar]
  • 5.Sánchez de la Torre C, Martínez MA, Almarza E (2005) Determination of several psychiatric drugs in whole blood using capillary gas-liquid chromatography with nitrogen phosphorus detection: comparison of two solid phase extraction procedures. Forensic Sci Int 155(2–3):193–204. 10.1016/j.forsciint.2004.12.007 [DOI] [PubMed] [Google Scholar]
  • 6.Drummer OH (2007) Requirements for bioanalytical procedures in postmortem toxicology. Anal Bioanal Chem 388(7):1495–1503. 10.1007/s00216-007-1238-7 [DOI] [PubMed] [Google Scholar]
  • 7.Sauvage FL, Picard N, Saint-Marcoux F, Gaulier JM, Lachâtre G, Marquet P (2009) General unknown screening procedure for the characterization of human drug metabolites in forensic toxicology: applications and constraints. J Sep Sci 32(18):3074–3083. 10.1002/jssc.200900092 [DOI] [PubMed] [Google Scholar]
  • 8.Johnson RD, Botch SR (2011) The screening of forensic blood, urine, and tissue specimens for xenobiotics using ion-trap liquid chromatography-tandem mass spectrometry. J Anal Toxicol 35(2):65–74. 10.1093/anatox/35.2.65 [DOI] [PubMed] [Google Scholar]
  • 9.Usui K, Hayashizaki Y, Hashiyada M, Funayama M (2012) Rapid drug extraction from human whole blood using a modified QuEChERS extraction method. Leg Med 14(6):286–296. 10.1016/j.legalmed.2012.04.008 [DOI] [PubMed] [Google Scholar]
  • 10.Annesley TM (2003) Ion suppression in mass spectrometry. Clin Chem 49(7):1041–1044. 10.1373/49.7.1041 [DOI] [PubMed] [Google Scholar]
  • 11.Timmerman P, Anders Kall M, Gordon B, Laakso S, Freisleben A, Hucker R (2010) Best practices in a tiered approach to metabolite quantification: views and recommendations of the European Bioanalysis Forum. Bioanalysis 2(7):1185–1194. 10.4155/bio.10.90 [DOI] [PubMed] [Google Scholar]
  • 12.Panuwet P, Hunter RE Jr, D’Souza PE, Chen X, Radford SA, Cohen JR, Marder ME, Kartavenka K, Ryan PB, Barr D (2016) Biological matrix effects in quantitative tandem mass spectrometry-based analytical methods: Advancing Biomonitoring. Crit Rev Anal Chem 46(2):93–105. 10.1080/10408347.2014.980775 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Zhang S, He Z, Zeng M, Chen J (2023) Impact of matrix species and mass spectrometry on matrix effects in multi-residue pesticide analysis based on QuEChERS-LC-MS. Foods 12(6):1226. 10.3390/foods12061226 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Fuke C, Nagai T, Ninomiya K, Fukasawa M, Ihama Y, Miyazaki T (2014) Detection of imidacloprid in biological fluids in a case of fatal insecticide intoxication. Leg Med 16(1):40–43 [DOI] [PubMed] [Google Scholar]
  • 15.Rodrigues TB, Morais DR, Gianvecchio VAP, Aquino EM, Cunha RL, Huestis MA, Costa JL (2021) Development and validation of a method for quantification of 28 psychotropic drugs in postmortem blood samples by modified micro-QuEChERS and LC-MS-MS. J Anal Toxicol 45(7):644–656. 10.1093/jat/bkaa138 [DOI] [PubMed] [Google Scholar]
  • 16.Kusano M, Sakamoto Y, Natori Y, Miyagawa H, Tsuchihashi H, Ishii A, Zaitsu K (2019) Development of “Quick-DB forensic”: a total workflow from QuEChERS-dSPE method to GC-MS/MS quantification of forensically relevant drugs and pesticides in whole blood. Forensic Sci Int 300:125–135. 10.1016/j.forsciint.2019.03.048 [DOI] [PubMed] [Google Scholar]
  • 17.Cesbron A, Saussereau E, Mahieu L, Couland I, Guerbet M, Goullé JP (2013) Metallic profile of whole blood and plasma in a series of 106 healthy volunteers. J Anal Toxicol 37(7):401–405. 10.1093/jat/bkt046 [DOI] [PubMed] [Google Scholar]
  • 18.Chan EC, Pasikanti KK, Nicholson JK (2011) Global urinary metabolic profiling procedures using gas chromatography-mass spectrometry. Nat Protoc 6(10):1483–1499. 10.1038/nprot.2011.375 [DOI] [PubMed] [Google Scholar]
  • 19.Tulipani S, Llorach R, Urpi-Sarda M, Andres-Lacueva C (2013) Comparative analysis of sample preparation methods to handle the complexity of the blood fluid metabolome: when less is more. Anal Chem 85(1):341–348. 10.1021/ac302919t [DOI] [PubMed] [Google Scholar]
  • 20.Ismaie OA, Zhang T, Jenkins RG, Karnes HT (2010) Investigation of endogenous blood plasma phospholipids, cholesterol and glycerides that contribute to matrix effects in bioanalysis by liquid chromatography/mass spectrometry. J Chromatogr B 878(31):3303–3316. 10.1016/j.jchromb.2010.10.012 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Data Availability Statement

The datasets generated during the current study are available from the corresponding author upon reasonable request.


Articles from Forensic Toxicology are provided here courtesy of Springer

RESOURCES