Abstract
Results of neodymium-YAG laser iridotomy in 34 eyes with narrow drainage angles are reported. Iridotomies appeared patent on slit-lamp examination in 32 (94%) eyes. Complications included failed patency of iridotomy and acute elevation of intraocular pressure.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Abraham R. K. Procedure for outpatient argon laser iridectomies for angle-closure glaucoma. Int Ophthalmol Clin. 1976 Winter;16(4):1–14. [PubMed] [Google Scholar]
- BARKAN O. Narrow-angle glaucoma; pupillary block and the narrow-angle mechanism. Am J Ophthalmol. 1954 Mar;37(3):332–350. [PubMed] [Google Scholar]
- Bass M. S., Cleary C. V., Perkins E. S., Wheeler C. B. Single treatment laser iridotomy. Br J Ophthalmol. 1979 Jan;63(1):29–30. doi: 10.1136/bjo.63.1.29. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fankhauser F., Van der Zypen E. Future of the laser in ophthalmology. Trans Ophthalmol Soc U K. 1982 Apr;102(Pt 1):159–163. [PubMed] [Google Scholar]
- Jagger J. D., Marshall J., Hamilton A. M. Neodymium-YAG laser in ophthalmic practice--principles and early experience. Trans Ophthalmol Soc U K. 1985;104(Pt 2):181–190. [PubMed] [Google Scholar]
- Klapper R. M. Q-switched neodymium:YAG laser iridotomy. Ophthalmology. 1984 Sep;91(9):1017–1021. doi: 10.1016/s0161-6420(84)34183-5. [DOI] [PubMed] [Google Scholar]
- Latina M. A., Puliafito C. A., Steinert R. R., Epstein D. L. Experimental iridotomy with the Q-switched neodymium-YAG laser. Arch Ophthalmol. 1984 Aug;102(8):1211–1213. doi: 10.1001/archopht.1984.01040030981031. [DOI] [PubMed] [Google Scholar]
- McAllister J. A., Schwartz L. W., Moster M., Spaeth G. L. Laser peripheral iridectomy comparing Q-switched neodymium YAG with argon. Trans Ophthalmol Soc U K. 1985;104(Pt 1):67–69. [PubMed] [Google Scholar]
- Perkins E. S., Brown N. A. Iridotomy with a ruby laser. Br J Ophthalmol. 1973 Jul;57(7):487–498. doi: 10.1136/bjo.57.7.487. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Robin A. L., Pollack I. P. A comparison of neodymium: YAG and argon laser iridotomies. Ophthalmology. 1984 Sep;91(9):1011–1016. doi: 10.1016/s0161-6420(84)34199-9. [DOI] [PubMed] [Google Scholar]
- Schrems W., Eichelbrönner O., Krieglstein G. K. The immediate IOP response of Nd-YAG-laser iridotomy and its prophylactic treatability. Acta Ophthalmol (Copenh) 1984 Oct;62(5):673–680. doi: 10.1111/j.1755-3768.1984.tb05794.x. [DOI] [PubMed] [Google Scholar]