Abstract
Severe mitral annular calcification (MAC) presents a surgical challenge due to the complexity of disease and the risk of valve replacement. There have been a variety of techniques to combat this risk including edge-to-edge repair, collar-enforced prosthesis, and pericardial patch techniques. This report highlights a case in which a novel reproducible surgical technique was used to prevent perivalvular leak with mitral valve replacement. This technique may add to surgeons' repertoire in addressing patients with MAC concentrated on the posterior annulus.
Keywords: valve, endocarditis, cardiac surgery, calcium, dystrophic calcification cardiovascular disease, novel technique
Mitral annular calcification (MAC) is the chronic degeneration of the fibrous base of the mitral valve structure. The dystrophic calcification is more common and severe on the posterior annulus but may be diffuse and extend into the anterior annulus and left ventricular myocardium. 1 MAC has a high reported clinical prevalence between 8 and 15% and is strongly linked to age-related degeneration, the female sex, atherosclerosis, hypertension and other conditions of mitral valve stress, and chronic kidney disease. 1 2 MAC carries severe clinical implications, including increased cardiovascular disease, mitral valve disease, arrhythmias, and cardiac surgery complications. 1 Surgical repair of the sequela of MAC and other pathologies is challenging and associated with high intraoperative complications due to the bulky annular calcification hindering repair, suture placement, and valve prosthesis insertion. 2 Commonly observed complications include atrioventricular junction rupture, left ventricular free wall rupture, left circumflex artery compromise, paravalvular leak, and valvular dehiscence. 2 Current procedures in practice include edge-to-edge mitral repair, ultrasound debridement, collar-enforced prosthesis, and the use of autologous or bovine pericardium. 2 These surgical approaches are furthermore modified by mitral valve replacement with or without annular reconstruction. Consensus on the surgical approach for patients with MAC remains elusive and is determined on a case-to-case basis—our technique reports a novel technique for mitral valve replacement in a patient with severe posterior MAC needing valve replacement.
Case Report
A 74-year-old female with a history of intravenous drug abuse, hypertension, hyperlipidemia, diabetes mellitus, and endometrial cancer presented to the emergency department with altered mental status. She was found to have methicillin-sensitive staphylococcus aureus (MSSA) endocarditis with a 1.0 cm vegetation on the posterior leaflet of the mitral valve. Her echocardiogram revealed severe MAC, but no mitral regurgitation and intact cardiac function. Due to her persistent MSSA blood cultures and the risk of embolization of the valve vegetation, she was taken for surgery. She was taken to the operating room and placed on cardiopulmonary bypass. Extensive MAC disproportionately affected the posterior annulus leading to the following described technique. As seen in Fig. 1 , the mitral valve was excised, and protruding annular calcification which was readily debrided was removed. Sixteen valve sutures were placed from the underside of the annulus including through the debreeded calcification on the posterior annulus. The valve was sized for a 29-mm bioprosthetic valve. A bovine pericardial patch was sewn to the posterior portion of the bioprosthetic mitral valve. The annular sutures were placed through the valve, and the valve was then tied down. A running 4-0 Prolene double suture line was then used to tack the patch to the roof of the atrium. This allowed additional security for the posterior aspect of the bioprosthesis in the event that any of the posterior valve sutures tore through the calcification. There was no paravalvular leak identified postoperatively, and the patient recovered after a short hospital stay. The patient was stable 1 year after the operation, and no reintervention was needed.
Fig. 1.

( A ) Native mitral valve is excised and readily removed calcium is debrided. ( B ) Bovine pericardial patch is attached to the bioprosthetic mitral valve. ( C ) Bioprosthetic valve is sewn into the mitral valve annulus. ( D ) Pericardial patch is sewn to the atrium above the mitral annular calcification.
Discussion
Bovine pericardial patches have previously been described as a possible treatment to prevent paravalvular leak in mitral valve replacement with severe MAC. Iacona and colleagues describe a posterior mitral skirt technique in which a bovine pericardial patch is sutured to the junction of MAC and the healthy ventricular myocardium below the annulus. 3 Valve sutures are then passed through the ventricular side of the patch, MAC, and back through the patch on the atrial side. The patch is then sutured to the atrial wall, and the valve is subsequently sized and implanted. The authors note difficulties in this technique due to difficulty in suturing the patch to the ventricular MAC junction. They also note the fragility of the myocardium and the possibility of patch dehiscence after the removal of the aortic cross-clamp. Our technique differs from the one described by Iacona and colleagues due to the positioning of the pericardial patch suture line. As seen in Figs. 1 and 2 , in our technique, the inferior side of the patch is sutured directly to the implanted valve. This eliminates the inferior suture line in the ventricular myocardium. With the patch sutured directly to the valve and atrial wall, our technique still has the major benefit of preventing paravalvular leak but limits some of the challenges with the previously described technique.
Fig. 2.

Intraoperative image. White arrow showing bioprosthetic mitral valve. Black arrow showing atrial suture line of the bovine pericardial patch.
Another technique presented by Senzai and colleagues is a circumferential pericardial patch technique. 4 The patch is sewn to the replacement mitral valve and, then, sewn to the atrium circumferentially. As MAC is predominantly on the posterior leaflet, our technique differs by covering the posterior mitral valve, preventing perivalvular leak, but limits the complexity of a 360 degree patch. In cases with MAC affecting the posterior annulus, we believe this report highlights a reproducible and effective method for preventing paravalvular leak.
Footnotes
Conflict of Interest None declared.
References
- 1.Abramowitz Y, Jilaihawi H, Chakravarty T, Mack M J, Makkar R R. Mitral annulus calcification. J Am Coll Cardiol. 2015;66(17):1934–1941. doi: 10.1016/j.jacc.2015.08.872. [DOI] [PubMed] [Google Scholar]
- 2.Okada Y. Surgical management of mitral annular calcification. Gen Thorac Cardiovasc Surg. 2013;61(11):619–625. doi: 10.1007/s11748-013-0207-7. [DOI] [PubMed] [Google Scholar]
- 3.Iacona G M, Ali S O, Unai S, Harb S C, Pettersson G B. Mitral valve replacement in patients with severe mitral calcification. JTCVS Tech. 2021;11:7–9. doi: 10.1016/j.xjtc.2021.11.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Senzai M, Tsutsumi Y, Monta Oet al. A technique in mitral valve surgery with mitral annular calcificationAATS2017