Abstract
Amyloidosis is a protein misfolding disease caused by the deposition of large, insoluble aggregates (amyloid fibrils) of protein in a tissue, which has been associated with various conditions, such as lymphoid disorders, Alzheimer’s disease, diabetes mellitus type 2, chronic inflammatory processes, and cancers. Amyloid fibrils are commonly diagnosed by qualitative observation of green birefringence from Congo red-stained biopsy tissue samples under polarized light, a technique that is limited by lack of specificity, dependence on subjective interpretation, and technical constraints. Studies emphasize the utility of quantitative polarized light microscopy (PLM) methodology to diagnose amyloid fibrils in Congo red-stained tissues. However, while Congo red enhances the intrinsic birefringence of amyloid fibrillar structures, there are significant disadvantages, such as the appearance of multiple non-green colors under polarized light and binding to other structures, which may result in misdiagnoses with Congo red dye and inconclusive explanations. In this work, we present an improved PLM methodology for the quantitative detection of amyloid fibrils without requiring Congo red staining. We perform PLM measurements on four tissues: abdominal subcutaneous tissue biopsy, duodenal biopsy, thyroid biopsy, and breast biopsy, both with Congo red stain and hematoxylin and eosin (H&E) stain, and through Fourier analysis, quantify birefringence, birefringent axis orientation, dichroism, optical activity, and relative amyloid density. These results emphasize a quantitative analysis for amyloid diagnosis rooted in Fourier signal harmonics that does not require Congo red dye and paves the way for rapid, simple, and accurate diagnosis of amyloid fibrils.
1. Introduction
Amyloids, historically named for their ‘starch-like’ appearance upon iodine staining, are aggregates of misfolded, self-assembled proteins that form highly insoluble structures known as amyloid fibrils. These fibrils exhibit a characteristic cross- fiber diffraction pattern under X-ray. Pathogenic fibril deposition disrupts normal tissue architecture, leading to organ dysfunction and a series of disorders collectively known as amyloidosis [1–5]. Of clinical significance, a certain kind of amyloid fibrils, amyloid- , are a defining neuropathological feature of Alzheimer’s disease [6–8]. Additionally, amyloid formation has been implicated to be related with cancer [9–12], lymphoid disorders [13–15], diabetes mellitus type 2 [16–19], and chronic inflammatory conditions [20–22]. Nonetheless, it is important to note that amyloid formation is not just associated with disease states. It is a well-defined structural form of the protein, alternative to the native state, that may be adopted by many polypeptide sequences [23,24]. Certain amyloids may play functional roles in the human body, such as in storage of peptide hormones and necroptosis of cells [25].
It has been indicated that the diagnosis of amyloidosis is often delayed due to the the nondescript main symptoms of such diseases [26–28]. Timely diagnosis and treatment plays a crucial role in the management of amyloidosis [29–32] in order to prevent severe tissue damage and dysfunction [33–35]. However, with current methods, patients commonly need to see multiple physicians, in specific referral centers with well-trained pathologists, increasing the time to diagnosis [33].
Amyloids can be seen on standard hematoxylin and eosin (H&E) stain, appearing as amorphous eosinophilic deposits. However, H&E staining alone is not specific enough to differentiate from visually similar tissue changes, such as hyaline deposits. Therefore, other more specific stains are required to confirm the diagnosis. Despite the development of more specific immunohistochemical stains for certain amyloids, such as amyloid- associated with Alzheimer’s disease [9,36–40], the gold standard for the detection of amyloid fibrils in most histopathology laboratories is still to stain tissue samples with Congo red dye [41,42]. Congo red stain enhances the intrinsic birefringence of amyloid fibrils [1,43–46] and when observed under a microscope with crossed polarizers ( offset), Congo red stained amyloids exhibit ‘apple green’ birefringence, allowing for trained pathologists to qualitatively identify amyloid fibrils [47–49].
Congo red staining with polarized microscopy is limited by lack of specificity for amyloid deposits, variable sensitivity, dependence on subjective interpretation, and technical constraints [50,51]. In standard clinics, the lenses used in the microscopes are manufactured with strain, which will affect the observations under polarized light and leads to observations of several colours [50–53]. This can result in misdiagnosis of amyloid fibrils and confusion among scientists that green and only green is indicative of amyloid when stained with Congo red [54,55]. Additionally, ‘apple green’ birefringence is a qualitative description, dependent on the observers’ subjective judgment, in need of replacement with quantitative methods as motivated by work strongly correlating amyloid density and structure, in certain cases, with disease outcomes [4,5,9–12,56–63]. Furthermore, there is ample evidence that Congo red binds to several other substances other than amyloid, confirming that detecting birefringence with Congo red stained samples is not specific for amyloid [41,64–68].
In this work we have implemented a polarized light microscopy (PLM) system capable of detecting and quantifying birefringent material such as amyloid in biological samples stained with H&E, bypassing the limitations associated with Congo red staining. We apply PLM techniques [47,69–74] to quantify birefringence, birefringent axis orientation, dichroism, optical activity, and relative amyloid density through Fourier analysis. We measure birefringence contrast maps using a polarizer/analyzer pair for H&E stained biological tissue samples and obtain results comparable to Congo red stained samples with the expected reduced contrast [43,44,51,53]. This work opens the door for techniques identifying and determining amyloid density based on its intrinsic birefringence, providing a Congo red-free alternative to conventional methods. It further complements recent advances in deep learning-based analysis [75] and quantitative polarimetric imaging [76–78], which have shown promise in assessing amyloid deposits and disease progression while reducing or eliminating the need for traditional tissue sectioning and staining.
2. Materials and methods
2.1. Human tissue samples
Samples were obtained from Sunnybrook Hospital (Toronto, Canada) with appropriate institutional ethics approval. Hospital pathology files were searched for term “amyloid" to retrospectively identify cases of confirmed amyloidosis. Four cases of amyloidosis were included: 1) duodenal biopsy from patient with multiple myeloma, 2) abdominal subcutaneous tissue biopsy from a patient with macroglossia and elevated serum kappa light chains, 3) thyroid biopsy from patient with medullary thyroid carcinoma, and 4) breast biopsy from patient with mammary amyloidosis with light chain immunoglobulin type amyloid (AL amyloid) detected by mass spectrometry. We selected four most recent identified cases with an aim to include several different tissue sites and at least two different amyloid subtypes. Two consecutive m thick sections are prepared from retrieved formalin fixed paraffin embedded (FFPE) tissue blocks and mounted on glass slides. The first section is stained with H&E and the second section is stained with Congo Red, following the respective standard clinical pathology laboratory protocols [41,79].
Two pathologists (JM, MAA) identified several regions of interest (ROIs) (either amyloid or normal tissue) on Congo red stained slides and the corresponding areas on the H&E stained slides using a Nikon Eclipse E400 Biological Microscope. Several steps were taken to ensure spatial correspondence between the two sections for all imaging and analysis. The consecutive H&E and Congo Red sections without tissue wasting were prepared. The pathologists visually inspected H&E slides for features suggestive of amyloid accumulation (as it is done in clinical practice) and marked the areas of interest on H&E slide. Next, the pathologists examined the Congo Red stained slides to confirm the presence of amyloid in the areas of interest (as it is done in clinical practice). Two areas per case with confirmed amyloid on Congo Red were selected for image analysis on both Congo Red and H&E stained slides. The pathologist made sure that the exact same area on the H&E and Congo Red were selected for image analysis. This was achieved by careful visual inspection and comparing of both slides. Pathologists looked for an exact location of the area of interest in the specific tissue fragment, and compared its location in the context of architectural arrangement and landmarks in the surrounding tissue constituents (such as vessels, glands, epidermal-to-stromal junction, etc.). In all cases, the two pathologists who are co-authors in this study were certain that the same area imaged on the H&E slide was also imaged on the Congo Red slide. These samples were then placed within our PLM setup described below.
2.2. Polarized light microscopy system
We implemented a custom PLM system as shown in the schematic in Fig. 1. A Fabry-Perot benchtop 520 nm (green light) laser source is operated at 5 mW and fiber coupled to a collimator. A fixed linear film polarizer and a 520 nm zero-order quarter-wave plate (not shown in Fig. 1) are placed before the rotating linear polarizer, which is mounted on a rotation stage driven by a motor controller. The sample slide is mounted to a triple axis linear translation stage for sample positioning and focusing. After the sample, a 10x stress- and strain-free objective collects the transmitted light, followed by another linear polarizer (the ‘analyzer’) within a continuous rotation mount (the same as for the polarizer) operated by a motor controller. A CMOS camera with tube lens is used for all image acquisition. The entire setup is in an enclosure composed of black anodized aluminum and blackout nylon fabric with polyurethane coating to reduce background light, on top of a optical table with active isolation to reduce vibrations. In this study, the green laser was chosen for improved contrast, birefringence, transmission, and reduced scattering. Autoflorescence and scattering effects are taken into account by measuring normal tissue for all samples (see Supplement 1 (4.4MB, pdf) ).
Fig. 1.
A simplified schematic of the PLM optical setup. A 520 nm green laser passes through a linear polarizer on a rotation mount before interacting with the sample. A 10x objective, that is strain- and stress-free, collects light after the sample, before the other linear polarizer on a rotation mount (the analyzer). Lastly, images are acquired using a CMOS camera with proper tube lens connected to a laptop.
All image acquisition is automated with custom Python scripts. The script begins when the pathologist has focused the image and sets the exposure time. The polarizer/analyzer pair are initially aligned (parallel position) and rotated together in 10 steps, acquiring 37 images. For each image acquisition, multiple-exposure High Dynamic Range (HDR) imaging techniques are employed to increase the dynamic range of the images and reduce the number of over/underexposed pixels [80]. Afterwards, this measurement is repeated with the analyzer rotated with respect to the polarizer (crossed position). Finally, 37 more images are acquired for a fixed polarizer orientation while the analyzer rotates over , used for quantifying optical activity. Each image has a resolution of 1216 by 1936 pixels, corresponding to an image size of about m by m, where a pixel size of about m is obtained via calibration with standard Thorlabs USAF resolution targets. Further setup calibration is performed by measuring standard birefringent resolution targets to check birefringence of individual components and measuring normal tissue for all samples (see Supplement 1 (4.4MB, pdf) ). We find that automated acquisition improves the reproducibility of the measurements and reduces the potential of environmental factors influencing longer manual measurements. HDR imaging improves the image quality and quality of the measured data due to the wider dynamic range over which one can observe intensity oscillations as the polarizer/analyzer rotates.
2.3. Analysis methods
Theoretically, no light will be detected at the camera when there is no sample between crossed polarizers [81]. However, a sample exhibiting birefringence located between the crossed polarizers can rotate the incoming polarized light to become elliptically polarized resulting in light detection at the camera [81]. As the crossed polarizer pair is rotated, the transmitted intensity through the sample is a Fourier sum of the various optical contributions with Fourier frequency dominating for the birefringent structures:
| (1) |
where is the angle between the polarizer and the birefringent axis, is the difference between the fast and slow axis of the birefringent material, is the sample thickness, is the wavelength of the light, and is the transmitted intensity [73,82]. Using the crossed and parallel polarizer measurements we compute the normalized transmitted crossed intensity ratio:
| (2) |
where and are the sets of 37 respective cross and parallel polarizer transmitted intensity images captured by the camera. We filter the images by binning 4x4 regions of pixels together and then perform the two dimensional fast Fourier transform of . We compute the birefringence contrast , where is the amplitude of the Fourier frequency component and is the mean signal. Pathologists select high contrast regions from the birefringence contrast maps to verify the frequency intensity oscillations, characteristic of birefringence structure. To fit the data, we account for the signal being a Fourier sum of separate optical contributions, such as birefringence and dichroism [52]:
| (3) |
where determines the mean (background) signal, and are the respective amplitudes, phases, and frequencies of the birefringence and dichroism terms, and is the polarizer angle varying from to . We determine , the difference between the fast and slow axis of the birefringent structure, from Eq. (1), (2).
As described in Ref. [47], birefringence and dichroism are not distributed evenly. The dichroism contribution is described by:
| (4) |
where is the transmitted intensity, is the angle between the input polarization state and the least transmitting direction of the dichroism, and represents the differential absorption with defining the transmission difference between the transmitting directions. We quantify and for all samples using Eq. (3), (4).
From the varying brightness of the birefringent structure as the polarizer/analyzer are rotated, we define a metric to quantify the relative amount of amyloid within different regions of a single tissue sample, as well as across the various tissues themselves, which in qualitative terms spans the range ‘no amyloid’ to ‘high density of amyloid’. The normal tissue (see Supplement 1 (4.4MB, pdf) ), determines the ‘no amyloid’ end of the metric as the average value for Congo red and H&E ROI points is approximately equal to the uncertainty, demonstrating no Fourier frequency signal whatsoever. The ‘high density of amyloid’ end of the metric is determined by the measured birefringent structure exhibiting the largest variation in intensity which is found in the Congo red stained breast tissue sample. To quantify these values, we compute ratios of amplitudes and map to a normalized scale from 0 (‘no amyloid’) to 1 (‘high density of amyloid’).
In addition to birefringence contrast maps, we analyze the birefringence orientation for determining a structure’s birefringent axis, which is related to in Eq. (3). It is expected that regions of amyloid structure will exhibit smaller variations in birefringent orientation due to their alignment whereas non birefringent structures will exhibit comparatively larger fluctuations in phase [73]. From Eq. (1), if the highest transmission through cross polarizers occurs at angle , then the structure’s birefringent axis is one of . We quantify the birefringent axis for the amyloid observed in both Congo red and H&E stained samples for all tissue samples.
After the crossed and parallel polarizer measurements, the polarizer is fixed at and the analyzer is rotated . When the polarizer and analyzer are aligned (crossed), we expect maximum (minimum) intensity with Fourier frequency as given by:
| (5) |
where is normalized transmitted intensity at the camera, is the expected dominating Fourier frequency, is the analyzer angle, is the phase shift, is the background signal, and is the amplitude. If the sample is optically active, the sample can rotate the polarization direction between the polarizer pair resulting in a nonzero [83]. Furthermore, we compute the difference in refractive index for left and right circularly polarized waves from :
| (6) |
where is wavelength and is thickness of the sample [83]. Optical activity is a quantitative characteristic of amyloid as it relates to the chirality of the amyloid fibril structure. Since amyloid fibrils form from many protein aggregation pathways, studies analyze the relationship between chirality and biological behaviour, as well as using chirality for amyloid fibril diagnosis [84–86].
3. Results
Shown in Fig. 2 are the conventional light microscope images for all tissue samples described in section 2, alongside parallel polarizer images captured with the PLM system. The duodenal tissue sample is shown in Fig. 2(a) (i)-(iv) with the region shown indicating an ROI from the pathologist to contain amyloid and adjacent normal tissue. H&E image (Fig. 2(a) (iii)) shows duodenal glands adjacent to amorphous eosinophilic material. Identical area is imaged on the Congo red stain (Fig. 2(a) (i)) with amorphous eosinophilic material confirmed to be amyloid. We measure the birefringence contrast as described in section 2 and shown in Fig. 3(a),(c) for both the Congo red and H&E stained duodenal tissue section. We analyze high contrast regions R0 and R1 in Fig. 3(b),(d) and observe the intensity oscillations (from Eq. (2)) as a function of polarizer angle. Clearly, for both the Congo red and H&E stained sample, the characteristic Fourier frequency component of birefringence structure dominates the signal. Also, as expected, birefringence contrast is visible in the H&E stained samples with reduced contrast compared to Congo red as Congo red enhances intrinsic birefringence already present in any structures, amyloid fibrils and otherwise [43,44,51,53]. We take reference measurements of normal duodenal tissue, as shown in Fig. S1, S2 in the Supplement 1 (4.4MB, pdf) , and we observe no birefringence in the normal tissue sample as expected.
Fig. 2.
Conventional light microscope images at 40x magnification (i and iii) alongside the corresponding image taken with our custom PLM system in the parallel polarizer configuration (ii and iv). Columns a-d) represent four different samples: duodenal biopsy, abdominal subcutaneous tissue biopsy, thyroid biopsy, and breast biopsy, with eosinophilic amorphous material confirmed to be amyloid. Rows i-ii) are for Congo red stained samples and iii-iv) are for H&E stained samples. In iii) c), the unfocused region may be a result of a tissue defect/artifact.
Fig. 3.
a) The computed birefringence contrast for the Congo red stained duodenal tissue sample. Labels R0 and R1 correspond to analyzed pixels in b), plotting measured intensity T from Eq. (2) as a function of polarizer angle. The dominant frequency is clearly observed as expected for birefringent structures. The data is well described by Eq. (3) which considers the characteristic frequency of birefringence and frequency of dichroism. In c-d) are the analogous figures to a-b) for the H&E stained sample. As expected, contrast is diminished but the intrinsic birefringence of amyloid fibrils is still observable.
We fit the data with Eq. (3) and provide the fit parameters for the duodenal tissue sample in the Supplement 1 (4.4MB, pdf) in Table. S1 for reference. From Eq. (1), we quantify the birefringence of the sample as mentioned in Ref. [73]. For the Congo red and H&E stained duodenal tissue sample, for the R0 and R1 regions are computed from the fit and summarized in Table. 1. We observe a consistent significant difference between the computed values for Congo red and H&E stained samples due to the large expected differences in observed contrast depending on the staining method [43,44,51,53]. For example, for R0 of the Congo red (H&E) stained sample, the refractive index difference between the fast and slow axis is ( ). From these measurements we also quantify relative amounts of amyloid present in the samples as described in section 2 and summarized in Table. 2. The density of amyloid metric compares variations in brightness as determined by the amplitude in Eq. (3), similar to the methods used in Ref. [73]. Notably, since Congo red enhances the contrast of birefringent structures, this metric predicts that all Congo red stained samples contain more amyloid then the H&E stained samples. Thus, we conclude that this metric for quantifying relative amount of amyloid is well-suited for comparing density across different samples with the same staining procedure and should not be used to make claims on amyloid amount between Congo red and H&E.
Table 1. Computed birefringence values (Eq. (1)) for the duodenal, abdominal subcutaneous, thyroid, and breast tissue samples.
| Birefringence (
)
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Duodenal tissue | ||||
| Abdominal subcutaneous tissue | ||||
| Thyroid tissue | ||||
| Breast tissue | ||||
Table 2. Quantifying the relative amount of amyloid between the different samples and different staining methods as described in section 2. The normalized metric ranges from 0 (‘no amyloid’) to 1 (‘high density of amyloid’). Note that the enhanced birefringent contrast with Congo red samples significantly alters the determination of amount of amyloid with this metric and thus it is best to compare the stains separately.
| Relative amount of amyloid
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Duodenal tissue | ||||
| Abdominal subcutaneous tissue | ||||
| Thyroid tissue | ||||
| Breast tissue | ||||
The computed birefringence values are further modified due to the linear dichroism term, as seen in Eq. (3), (4) and described in section 2. From the measurements, we quantify , the normalized difference between transmitted intensities for the primary polarizations, and summarize the results in Table 3. We observe that the dichroism contribution is comparable for both the Congo red and H&E stained samples, indicating that, as expected, Congo red primarily enhances birefringence.
Table 3. Computed linear dichroism values (Eq. (4)) for the duodenal, abdominal subcutaneous, thyroid, and breast tissue samples.
| Linear Dichroism (
)
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Duodenal tissue | ||||
| Abdominal subcutaneous tissue | ||||
| Thyroid tissue | ||||
| Breast tissue | ||||
We analogously characterize the other biological tissue samples and observe similar results whereby the birefringence of amyloid is detectable without using Congo red staining. Shown in Fig. 2(b) (i)-(iv) and Fig. 4 are microscope images and birefringence contrast for an abdominal subcutaneous tissue sample. H&E image (Fig. 2(b) iii)) shows adipose tissue infiltrated by amorphous eosinophilic material. Identical area is imaged on the Congo red stain (Fig. 2(b) (i)) with amorphous eosinophilic material confirmed to be amyloid. Once again, we observe birefringence in both the Congo red and H&E stained samples, with lower contrast in the H&E stained sample as expected.
Fig. 4.
a) The computed birefringence contrast for the Congo red stained abdominal subcutaneous tissue sample. Labels R0 and R1 correspond to analyzed pixels in b), plotting measured intensity T from Eq. (2) as a function of polarizer angle. The dominant frequency is clearly observed as expected for birefringent structures. The data is well described by Eq. (3) which considers the characteristic frequency of birefringence and frequency of dichroism. In c-d) are the analogous figures to a-b) for the H&E stained sample. As expected, contrast is diminished but the intrinsic birefringence of amyloid fibrils is still observable.
Shown in Fig. 2(c) (i)-(iv) and Fig. 5 are the microscope images and birefringence contrast for the thyroid medullary carcinoma sample. H&E image (Fig. 2(c) (iii)) shows thyroid medullary carcinoma cells embedded in eosinophilic amorphous eosinophilic material. Identical area is imaged on the Congo red stain (Fig. 2(c) (i)) with amorphous eosinophilic material confirmed to be amyloid.
Fig. 5.
a) The computed birefringence contrast for the Congo red stained thyroid medullary carcinoma tissue sample. Labels R0 and R1 correspond to analyzed pixels in b), plotting measured intensity T from Eq. (2) as a function of polarizer angle. The dominant frequency is clearly observed as expected for birefringent structures. The data is well described by Eq. (3) which considers the characteristic frequency of birefringence and frequency of dichroism. In c-d) are the analogous figures to a-b) for the H&E stained sample. As expected, contrast is diminished but the intrinsic birefringence of amyloid fibrils is still observable.
Shown in Fig. 2(d) (i)-(iv) and Fig. 6 are the microscope images and birefringence contrast for the breast tissue sample. H&E image (Fig. 2(d) (iii)) shows breast stromal tissue infiltrated by amorphous eosinophilic material. Identical area is imaged on the Congo red stain (Fig. 2(d) (i)) with amorphous eosinophilic material confirmed to be amyloid. The computed birefringence for all samples and relative amyloid metric are summarized in Tables. 1, 2.
Fig. 6.
a) The computed birefringence contrast for the Congo red stained breast tissue sample. Labels R0 and R1 correspond to analyzed pixels in b), plotting measured intensity T from Eq. (2) as a function of polarizer angle. The dominant frequency is clearly observed as expected for birefringent structures. The data is well described by Eq. (3) which considers the characteristic frequency of birefringence and frequency of dichroism. In c-d) are the analogous figures to a-b) for the H&E stained sample. As expected, contrast is diminished but the intrinsic birefringence of amyloid fibrils is still observable.
For further analysis of the optical properties of the samples, we fix the polarizer orientation and only rotate the analyzer to compute the optical activity of the sample, as shown in Fig. 7 for the abdominal subcutaneous tissue sample. In some cases, such as point R1 of the H&E stained sample, we observe statistically significant sample induced rotation of several degrees, indicating an optically active sample. Typically, the optical rotation is near with several degrees of uncertainty, indicating that there is no significant optical activity. The optical activity results are summarized in Table. 4.
Fig. 7.
a,b) Optical activity measurements for the subcutaneous cellular tissue sample whereby the polarizer is fixed and the analyzer rotates . Region of interest points R0 and R1 are the same as those shown in Fig. 4. The data is in excellent agreement with theory given by Eq. (5).
Table 4. Computed optical activity induced phase shift ( ) and (Eq. (6)) values for the abdominal subcutaneous tissue, thyroid, and breast tissue samples.
| Optical Activity (
)
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Abdominal subcutaneous tissue | , | , | , | , |
| Thyroid tissue | , | , | , | , |
| Breast tissue | , | , | , | , |
In Fig. 8 we identify the contrast of the two main Fourier harmonics for this analysis, birefringence and dichroism, for all measurements in Figs. 3, 4, 5, 6. We observe that Congo red stained samples exhibit larger birefringence harmonics than all the H&E stained samples whereas the dichroism harmonic contrast varies between the two different stains. Furthermore, we compare the Fourier spectrum for the lowest birefringence contrast ROI (H&E R0 from Fig. 4) with normal tissue (Congo red R1 from Fig. S2 in the Supplement 1 (4.4MB, pdf) ) and observe that H&E R0 maintains a dominating birefringence harmonic in comparison to other frequencies (namely ), while the normal tissue spectrum is much noisier.
Fig. 8.
Contrast of the birefringence and dichroism harmonics for Congo red (CR) and H&E (HE) stained samples a)-d) (corresponding to Fig. 2 a)-d)) for points R0, R1 from Figs. 3, 4, 5, 6. The reference Fourier spectrum for a normal tissue region (Congo red R1 from Fig. S2 in the Supplement 1 (4.4MB, pdf) ) is shown in solid black, indicating a noisy Fourier signal and lacking the dominate birefringence harmonic. We also plot in dark red the Fourier spectrum in this range for the lowest measured birefringence contrast ROI (H&E R0 from Fig. 4) indicating dominating birefringence and dichroism harmonics in comparison to the contributions, which are large in the normal tissue.
Furthermore, for all samples, we both qualitatively and quantitatively analyze birefringent orientation of the amyloid structure. Shown in Fig. 9, are the birefringent phase maps ( in Eq. (3) from ) in a focused region around the R0, R1 points for all samples. We observe that regions with birefringent structures exhibit areas of uniform phase, caused by tissue structure alignment. Presented in Table. 5 are the calculated birefringent axis orientations in the 4x4 pixel bins in the ROIs indicated by white circles in Fig. 9.
Fig. 9.
Analysis of birefringence structure orientation for all samples, alongside corresponding microscope images and birefringence contrast maps for comparison depicting identical areas. Columns a-d) are the duodenal, abdominal subcutaneous tissue, thyroid, and breast tissue samples respectively. Rows i-iii) (iv-vi)) are the microscope images, birefringence contrast, and birefringence phase results for Congo red (H&E) stained samples. The birefringent phase maps display from Eq. (3) from in bins in a focused region around the R0, R1 points for all samples. We restrict the phase maps to statistically significant values by comparing to birefringence contrast values above 0.3 for Congo red and 0.1 for H&E. Notably, the areas with a stronger birefringent structures exhibit regions of similar phase, i.e. similar birefringent axis alignment and thus likely tissue structural alignment.
Table 5. Computed birefringent orientation for R0, R1 regions of the Congo red and H&E stained tissue samples. From Eq. (3), the first maxima of the birefringent component occurs when the polarizer angle equals which implies that the birefringent orientation is from Eq. (1). The birefringent axis orientation maps corresponding to these values are in Fig. 9 in bins from .
| Birefringent Axis Orientation
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Duodenal tissue | ||||
| Abdominal subcutaneous tissue | ||||
| Thyroid tissue | ||||
| Breast tissue | ||||
We analogously analyze the dichroism contribution and measure dichroism phase maps representing the orientation of the most absorbing direction as shown in Fig. 10. We plot the absorption phase maps ( in Eq. (3) from ) in a focused region around the R0, R1 points for all samples and summarize the corresponding dichroism maximum absorption orientation (from Eq. (4)) in Table. 6. We observe that ROIs with significant dichroism modulation of the dominant birefringent oscillations (for example, see Fig. 3 HE R1, Fig. 4 HE R0, R1, CR R1, Fig. 5 HE R0, R1, Fig. 6 CR R1, HE R1) maintain similar values from Eq. (3), typically within uncertainty, confirming the relationship between dichroism and birefringence axis orientations [47,71,87], which have been indicated to be originated from the same microstructure and overlapping with each other [71].
Fig. 10.
Analysis of dichroism maximum absorption orientation for all samples, alongside corresponding microscope images and dichroism/absorption contrast maps for comparison depicting identical areas. Columns a-d) are the duodenal, abdominal subcutaneous tissue, thyroid, and breast tissue samples respectively. Rows i-iii) (iv-vi)) are the microscope images, absorption contrast, and absorption phase results for Congo red (H&E) stained samples. The absorption phase maps display from Eq. (3) from in bins in a focused region around the R0, R1 points for all samples. We restrict the phase maps identically to Fig. 9.
Table 6. Computed dichroism maximum absorption orientation for R0, R1 regions of the Congo red and H&E stained tissue samples from Eq. (3), (4). The dichroism maximum absorption orientation maps corresponding to these values are in Fig. 10 in bins from .
| Maximum absorption Orientation (
)
| ||||
|---|---|---|---|---|
| Sample | Congo red, R0 | Congo red, R1 | H&E, R0 | H&E, R1 |
|
| ||||
| Duodenal tissue | ||||
| Abdominal subcutaneous tissue | ||||
| Thyroid tissue | ||||
| Breast tissue | ||||
4. Discussion
This study demonstrates that PLM can be used to quantitatively identify and characterize amyloid fibrils in tissue sections without the need for Congo red staining. We introduce a simplified and potentially more objective method for amyloid detection, that is additionally capable of determining relevant optical properties of amyloid in tissue.
Through Fourier analysis, we extract maps of birefringence contrast, phase, and axis orientation, as well as absorption and optical activity, from our PLM measurements. These results show that the intrinsic birefringence of amyloid fibrils is readily detectable for tissue sections that are only stained with H&E, avoiding the several limitations associated with Congo red. Our results clearly show that the signal measured at the camera, as the cross-polarizer pair is rotated, is predominantly governed by birefringence and dichroism harmonics. We account for this behaviour in our fits composed of and frequency terms and find excellent agreement with the measured data. Through phase analysis, we compute birefringence structure orientation, observing that areas of birefringent structure exhibit regions of similar phase, indicating tissue structure alignment. We introduce a preliminary empirical metric for amyloid density, related to birefringence contrast, to enable relative comparisons across measured samples and to provide a more quantitative characterization of amyloid in tissue–moving beyond qualitative presence/absence-based evaluation. The stability of this metric is influenced by staining, since for example, Congo red enhances the amyloid birefringence. Future work will focus on developing a theoretical model to quantify amyloid density, structure, and type from PLM measurements, enabling a robust and streamlined approach to clinical amyloid diagnosis and characterization.
4.1. Perspectives
The gold standard for the detection of amyloid fibrils in most histopathology laboratories is to stain tissue samples with Congo red dye; however, immunohistochemistry (IHC) antibody analysis is also regularly used to confirm diagnosis. Congo red staining and PLM allows for the identification of amyloid deposits, while amyloid typing is performed by using IHC. Specific antibodies could be used in specific cases and in well-equipped laboratories to distinguish different forms of amyloidosis, such as anti-AA for AA amyloidosis, anti-AL for light-chain amyloidosis, and anti-TTR for transthyretin amyloidosis (ATTR). In comparison, PLM highlights amyloid fibrillar structure regardless of protein composition. In this study we demonstrate that PLM can be applied directly to H&E-stained slides, potentially simplifying workflow and bypassing limitations associated with Congo red staining. However, because PLM does not currently provide amyloid typing, IHC or other molecular techniques could remain necessary in specific cases to determine the specific protein composition of amyloid deposits if necessary. Thus, a combined approach–using H&E with PLM for amyloid identification and IHC for subtyping–could be utilized in specific cases.
Recent studies have also emphasized the need to minimize tissue staining and sectioning by quantifying polarization metrics of backscattered light from amyloid deposits in mouse brain tissue for Alzheimer’s disease diagnosis [76,77]. Moreover, the application of Mueller imaging polarimetry has proven to be a powerful approach for quantifying optical anisotropy parameters and may be well incorporated with our PLM methods for characterizing the degree of depolarization caused by interactions with amyloid in tissue [77,88,89]. Our results contribute to advancing the field past qualitative diagnoses of amyloid by enabling quantitative characterization of key features of amyloid fibrils, motivated by their potential correlation with disease outcomes in certain cases [4,5,9–12,57–62].
This work paves the way for many future studies with polarized light microscopy for amyloid diagnosis. For example, these imaging techniques might be applied for thin unstained pathology slides to detect amyloid fibrils entirely independent of staining methods. Additionally, these approaches are well positioned to integrate structured light analysis–which has gained significant traction in biomedical research over the past decade–including recent developments leveraging structured light and orbital angular momentum (OAM) to characterize entoptic phenomena [90–101]. Lattices of OAM states also present novel opportunities as specialized probes in biomedical contexts, with future advancements positioned to incorporate structured single photons [102–104]. Future work will expand the PLM methodology to explore the additional OAM degree of freedom, offering new tools to study complex sample structures.
4.2. Limitations
The presented methods rely on birefringence contrast measurements and currently do not differentiate between different types of amyloid, although this is a future direction of study. Additionally, while this study compares birefringence in H&E and Congo red-stained tissues, the sensitivity and specificity of this approach relative to other amyloid detection techniques, such as IHC or mass spectrometry, remain to be determined. The presence of tissue defects/artifacts (e.g. see Fig. 2 iii) c)) may affect birefringence measurements, but in principle these regions are simple to avoid for quantitative analysis. PLM measurements will detect birefringence and optical activity of any structures within the sample and is not amyloid fibril specific. Therefore, trained pathologists cross reference microscope images with birefringent contrast maps for verification of amyloids within samples. As a proof-of-concept pilot investigation, this study requires further validation with a larger sample size to confirm its diagnostic utility.
5. Conclusion
In this work we have implemented a polarized light microscopy system capable of detecting and quantifying birefringent material such as amyloid in biological samples without the need for Congo red staining. We compare birefringence maps of Congo red and H&E stained duodenal tissue, abdominal subcutaneous tissue, thyroid tissue, and breast tissue samples and clearly observe the Fourier frequency component characteristic of birefringent structure. We also quantify birefringent axis orientation, optical activity, amyloid fibril density, and linear dichroism for the various samples. The presented techniques provide a solution to the complications regarding Congo red stained samples for the purpose of detecting amyloid birefringence. These quantitative measurements are objective and more robust metrics of amyloid in tissue, compared to Congo Red, and may correlate with severity of disease state and disease outcomes.
Supplemental information
Funding
Natural Sciences and Engineering Research Council of Canada 10.13039/501100000038; Canada First Research Excellence Fund 10.13039/501100010785; Canada Excellence Research Chairs, Government of Canada 10.13039/501100002784; Canadian Cancer Society 10.13039/501100000147 (CCS); the Canadian Institutes of Health Research - Institute of Cancer Research 10.13039/501100000027 (CIHR-ICR); Brain Canada Foundation 10.13039/100009408 (BC) SPARK-21 ( 707098).
Disclosures
The authors declare no conflicts of interest.
Data availability
All data is included in the manuscript and/or supporting information.
Supplemental document
See Supplement 1 (4.4MB, pdf) for supporting content.
References
- 1.Eisenberg D. S., Sawaya M. R., “Structural studies of amyloid proteins at the molecular level,” Annu. Rev. Biochem. 86(1), 69–95 (2017). 10.1146/annurev-biochem-061516-045104 [DOI] [PubMed] [Google Scholar]
- 2.Baker K. R., Rice L., “The amyloidoses: Clinical features, diagnosis and treatment,” Methodist DeBakey Cardiovascular Journal 8(3), 3–7 (2012). 10.14797/mdcj-8-3-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Desikan K., Dhodapkar M., Hough A., et al. , “Incidence and impact of light chain associated (al) amyloidosis on the prognosis of patients with multiple myeloma treated with autologous transplantation,” Leukemia lymphoma 27(3-4), 315–319 (1997). 10.3109/10428199709059685 [DOI] [PubMed] [Google Scholar]
- 4.Patel S., Harbhajanka A., Mahon B., et al. , “A clinicopathological spectrum of tumoral amyloidosis: An incidental innocent tumor,” Am. J. Clin. Pathol. 144(suppl 2), A375 (2015). 10.1093/ajcp/144.suppl2.375 [DOI] [Google Scholar]
- 5.Schönland S. O., Hegenbart U., Bochtler T., et al. , “Immunohistochemistry in the classification of systemic forms of amyloidosis: a systematic investigation of 117 patients,” Blood, The Journal of the American Society of Hematology 119(2), 488–493 (2012). 10.1182/blood-2011-06-358507 [DOI] [PubMed] [Google Scholar]
- 6.Petkova A. T., Ishii Y., Balbach J. J., et al. , “A structural model for alzheimer’s β-amyloid fibrils based on experimental constraints from solid state nmr,” Proc. Natl. Acad. Sci. 99(26), 16742–16747 (2002). 10.1073/pnas.262663499 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Qiang W., Yau W.-M., Lu J.-X., et al. , “Structural variation in amyloid-β fibrils from alzheimer’s disease clinical subtypes,” Nature 541(7636), 217–221 (2017). 10.1038/nature20814 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Lu J.-X., Qiang W., Yau W.-M., et al. , “Molecular structure of β-amyloid fibrils in alzheimer’s disease brain tissue,” Cell 154(6), 1257–1268 (2013). 10.1016/j.cell.2013.08.035 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Mizejewski G. J., “Breast cancer and amyloid bodies: is there a role for amyloidosis in cancer-cell dormancy?” Breast Cancer: Targets Ther. 9, 287–291 (2017). 10.2147/BCTT.S131394 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Sengupta S., Singh N., Paul A., et al. , “p53 amyloid pathology is correlated with higher cancer grade irrespective of the mutant or wild-type form,” J. Cell Sci. 136(17), jcs261017 (2023). 10.1242/jcs.261017 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Iwahashi N., Ikezaki M., Komohara Y., et al. , “Cytoplasmic p53 aggregates accumulated in p53-mutated cancer correlate with poor prognosis,” PNAS nexus 1(3), pgac128 (2022). 10.1093/pnasnexus/pgac128 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Ghosh S., Salot S., Sengupta S., et al. , “p53 amyloid formation leading to its loss of function: implications in cancer pathogenesis,” Cell Death Differ. 24(10), 1784–1798 (2017). 10.1038/cdd.2017.105 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Sanchorawala V., Blanchard E., Seldin D., et al. , “Al amyloidosis associated with b-cell lymphoproliferative disorders: Frequency and treatment outcomes,” Am. J. Hematol. 81(9), 692–695 (2006). 10.1002/ajh.20635 [DOI] [PubMed] [Google Scholar]
- 14.Dhakal B., Harrington A. M., Stadler M. E., et al. , “Localized lymph node light chain amyloidosis,” Case Reports in Hematology 2015, 1–4 (2015). 10.1155/2015/816565 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Fujiwara T., Yasufuku K., Nakajima T., et al. , “Primary amyloidosis involving mediastinal lymph nodes diagnosed by ebus-tbna,” Respiratory Medicine CME 2(1), 51–53 (2009). 10.1016/j.rmedc.2008.08.001 [DOI] [Google Scholar]
- 16.Marzban L., Park K., Verchere C. B., “Islet amyloid polypeptide and type 2 diabetes,” Exp. Gerontol. 38(4), 347–351 (2003). 10.1016/S0531-5565(03)00004-4 [DOI] [PubMed] [Google Scholar]
- 17.Abedini A., Schmidt A. M., “Mechanisms of islet amyloidosis toxicity in type 2 diabetes,” FEBS Lett. 587(8), 1119–1127 (2013). 10.1016/j.febslet.2013.01.017 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Höppener J. W., Ahrén B., Lips C. J., “Islet amyloid and type 2 diabetes mellitus,” N. Engl. J. Med. 343(6), 411–419 (2000). 10.1056/NEJM200008103430607 [DOI] [PubMed] [Google Scholar]
- 19.Westermark P., Andersson A., Westermark G. T., “Islet amyloid polypeptide, islet amyloid, and diabetes mellitus,” Physiol. Rev. 91(3), 795–826 (2011). 10.1152/physrev.00042.2009 [DOI] [PubMed] [Google Scholar]
- 20.Scarpioni R., Ricardi M., Albertazzi V., “Secondary amyloidosis in autoinflammatory diseases and the role of inflammation in renal damage,” World journal of nephrology 5(1), 66 (2016). 10.5527/wjn.v5.i1.66 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Cunnane G., “Amyloid precursors and amyloidosis in inflammatory arthritis,” Curr. Opin. Rheumatol. 13(1), 67–73 (2001). 10.1097/00002281-200101000-00011 [DOI] [PubMed] [Google Scholar]
- 22.Brunger A. F., Nienhuis H. L., Bijzet J., et al. , “Causes of aa amyloidosis: a systematic review,” Amyloid 27(1), 1–12 (2020). 10.1080/13506129.2019.1693359 [DOI] [PubMed] [Google Scholar]
- 23.Fowler D. M., Koulov A. V., Balch W. E., et al. , “Functional amyloid–from bacteria to humans,” Trends Biochem. Sci. 32(5), 217–224 (2007). 10.1016/j.tibs.2007.03.003 [DOI] [PubMed] [Google Scholar]
- 24.Greenwald J., Riek R., “Biology of amyloid: structure, function, and regulation,” Structure 18(10), 1244–1260 (2010). 10.1016/j.str.2010.08.009 [DOI] [PubMed] [Google Scholar]
- 25.Brown A., Török M., “Functional amyloids in the human body,” Bioorg. Med. Chem. Lett. 40, 127914 (2021). 10.1016/j.bmcl.2021.127914 [DOI] [PubMed] [Google Scholar]
- 26.Lin H. M., Seldin D., Hui A.-M., et al. , “The patient’s perspective on the symptom and everyday life impact of al amyloidosis,” Amyloid 22(4), 244–251 (2015). 10.3109/13506129.2015.1102131 [DOI] [PubMed] [Google Scholar]
- 27.Hayman S. R., Lacy M. Q., Kyle R. A., et al. , “Primary systemic amyloidosis: a cause of malabsorption syndrome,” Am. J. Med. 111(7), 535–540 (2001). 10.1016/S0002-9343(01)00919-6 [DOI] [PubMed] [Google Scholar]
- 28.Gertz M. A., Kyle R. A., “Primary systemic amyloidosis-a diagnostic primer,” Mayo Clin. Proc. 64(12), 1505–1519 (1989). 10.1016/S0025-6196(12)65706-1 [DOI] [PubMed] [Google Scholar]
- 29.Rapezzi C., Merlini G., Quarta C. C., et al. , “Systemic cardiac amyloidoses: disease profiles and clinical courses of the 3 main types,” Circulation 120(13), 1203–1212 (2009). 10.1161/CIRCULATIONAHA.108.843334 [DOI] [PubMed] [Google Scholar]
- 30.Merlini G., Bellotti V., “Molecular mechanisms of amyloidosis,” N. Engl. J. Med. 349(6), 583–596 (2003). 10.1056/NEJMra023144 [DOI] [PubMed] [Google Scholar]
- 31.Rh F., “The systemic amyloidoses,” N Engl J Med 337(13), 898–909 (1997). 10.1056/NEJM199709253371306 [DOI] [PubMed] [Google Scholar]
- 32.Gertz M. A., Lacy M. Q., Dispenzieri A., “Amyloidosis: Recognition, confirmation, prognosis, and therapy,” Mayo Clin. Proc. 74(5), 490–494 (1999). 10.1016/S0025-6196(11)65130-6 [DOI] [PubMed] [Google Scholar]
- 33.Maurer M. S., Elliott P., Comenzo R., et al. , “Addressing common questions encountered in the diagnosis and management of cardiac amyloidosis,” Circulation 135(14), 1357–1377 (2017). 10.1161/CIRCULATIONAHA.116.024438 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Wechalekar A. D., Gillmore J. D., Hawkins P. N., “Systemic amyloidosis,” Lancet 387(10038), 2641–2654 (2016). 10.1016/S0140-6736(15)01274-X [DOI] [PubMed] [Google Scholar]
- 35.Dietrich S., Schönland S. O., Benner A., et al. , “Treatment with intravenous melphalan and dexamethasone is not able to overcome the poor prognosis of patients with newly diagnosed systemic light chain amyloidosis and severe cardiac involvement,” Blood, The Journal of the American Society of Hematology 116(4), 522–528 (2010). 10.1182/blood-2009-11-253237 [DOI] [PubMed] [Google Scholar]
- 36.Hardy J., Selkoe D. J., “The amyloid hypothesis of alzheimer’s disease: progress and problems on the road to therapeutics,” Science 297(5580), 353–356 (2002). 10.1126/science.1072994 [DOI] [PubMed] [Google Scholar]
- 37.Gremer L., Schölzel D., Schenk C., et al. , “Fibril structure of amyloid-β (1–42) by cryo–electron microscopy,” Science 358(6359), 116–119 (2017). 10.1126/science.aao2825 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Westermark P., Benson M. D., Buxbaum J. N., et al. , “Amyloid fibril protein nomenclature–2002.,” Amyloid 9(3), 197–200 (2002). 10.3109/13506120209114823 [DOI] [PubMed] [Google Scholar]
- 39.Ow S.-Y., Dunstan D. E., “A brief overview of amyloids and alzheimer’s disease,” Protein Sci. 23(10), 1315–1331 (2014). 10.1002/pro.2524 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Korczyn A. D., Grinberg L. T., “Is alzheimer disease a disease?” Nat. Rev. Neurol. 20(4), 245–251 (2024). 10.1038/s41582-024-00940-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Yakupova E. I., Bobyleva L. G., Vikhlyantsev I. M., et al. , “Congo red and amyloids: history and relationship,” Biosci. Rep. 39(1), BSR20181415 (2019). 10.1042/BSR20181415 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Benson M. D., Buxbaum J. N., Eisenberg D. S., et al. , “Amyloid nomenclature 2020: update and recommendations by the international society of amyloidosis (isa) nomenclature committee,” Amyloid 27(4), 217–222 (2020). 10.1080/13506129.2020.1835263 [DOI] [PubMed] [Google Scholar]
- 43.Taylor D. L., Allen R. D., Benditt E. P., “Determination of the polarization optical properties of the amyloid-congo red complex by phase modulation microspectrophotometry,” J. Histochem. Cytochem. 22(12), 1105–1112 (1974). 10.1177/22.12.1105 [DOI] [PubMed] [Google Scholar]
- 44.Wolman M., Bubis J., “The cause of the green polarization color of amyloid stained with congo red,” Histochem. Cell Biol. 4(5), 351–356 (1965). 10.1007/BF00306246 [DOI] [PubMed] [Google Scholar]
- 45.Smith M., Sharp J., Roberts C., “Giant amyloid spherulites reveal their true colours,” Soft Matter 8(14), 3751–3755 (2012). 10.1039/c2sm25147g [DOI] [Google Scholar]
- 46.Şen S., Sarsik Kumbaraci B., “Digitally reinforced polarization of hematoxylin-eosin in the diagnosis of renal amyloidosis,” Turkish Journal of Pathology 28(3), 204 (2012). 10.5146/tjpath.2012.01126 [DOI] [PubMed] [Google Scholar]
- 47.Jin L.-W., Claborn K. A., Kurimoto M., et al. , “Imaging linear birefringence and dichroism in cerebral amyloid pathologies,” Proc. Natl. Acad. Sci. 100(26), 15294–15298 (2003). 10.1073/pnas.2534647100 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Cohen A. S., “General introduction and a brief history of amyloidosis,” in Amyloidosis , Van Rijswijk J. M., eds. (Springer, 1986), pp. 3–19. [Google Scholar]
- 49.Elghetany M. T., Saleem A., “Methods for staining amyloid in tissues: a review,” Stain Technol. 63(4), 201–212 (1988). 10.3109/10520298809107185 [DOI] [PubMed] [Google Scholar]
- 50.El-Meanawy A., Mueller C., Iczkowski K. A., “Improving sensitivity of amyloid detection by congo red stain by using polarizing microscope and avoiding pitfalls,” Diagn. Pathol. 14(1), 57 (2019). 10.1186/s13000-019-0822-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Howie A. J., Brewer D. B., “Optical properties of amyloid stained by congo red: history and mechanisms,” Micron 40(3), 285–301 (2009). 10.1016/j.micron.2008.10.002 [DOI] [PubMed] [Google Scholar]
- 52.Howie A. J., Brewer D. B., Howell D., et al. , “Physical basis of colors seen in congo red-stained amyloid in polarized light,” Lab. Invest. 88(3), 232–242 (2008). 10.1038/labinvest.3700714 [DOI] [PubMed] [Google Scholar]
- 53.Howie A. J., “Origins of a pervasive, erroneous idea: The “green birefringence” of congo red-stained amyloid,” Int. J. Exp. Pathol. 100(4), 208–221 (2019). 10.1111/iep.12330 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Bowen K., Shah N., Lewin M., “Al-amyloidosis presenting with negative congo red staining in the setting of high clinical suspicion: a case report,” Case reports in nephrology 2012, 1–4 (2012). 10.1155/2012/593460 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Senecal J. B., Abou-Akl R., Allevato P., et al. , “Amyloidosis: a case series and review of the literature,” Journal of Medical Case Reports 17(1), 184 (2023). 10.1186/s13256-023-03886-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Novikova T., Pierangelo A., De Martino A., et al. , “Polarimetric imaging for cancer diagnosis and staging,” Opt. Photonics News 23(10), 26 (2012). 10.1364/OPN.23.10.000026 [DOI] [Google Scholar]
- 57.Rogers S. S., Venema P., van der Ploeg J. P., et al. , “Electric birefringence study of an amyloid fibril system: The short end of the length distribution,” Eur. Phys. J. E 18(2), 207–217 (2005). 10.1140/epje/i2005-10038-2 [DOI] [PubMed] [Google Scholar]
- 58.Rogers S. S., Venema P., Sagis L. M., et al. , “Measuring the length distribution of a fibril system: a flow birefringence technique applied to amyloid fibrils,” Macromolecules 38(7), 2948–2958 (2005). 10.1021/ma0474224 [DOI] [Google Scholar]
- 59.Clement C. G., Truong L. D., “An evaluation of congo red fluorescence for the diagnosis of amyloidosis,” Hum. Pathol. 45(8), 1766–1772 (2014). 10.1016/j.humpath.2014.04.016 [DOI] [PubMed] [Google Scholar]
- 60.Beach T. G., Sue L. I., Walker D. G., et al. , “Striatal amyloid plaque density predicts braak neurofibrillary stage and clinicopathological alzheimer’s disease: implications for amyloid imaging,” J. Alzheimer’s Dis. 28(4), 869–876 (2012). 10.3233/JAD-2011-111340 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Mahato J., Ray K. K., Das S., et al. , “Investigation of structural heterogeneity in individual amyloid fibrils using polarization-resolved microscopy,” J. Phys. Chem. B 125(49), 13406–13414 (2021). 10.1021/acs.jpcb.1c08604 [DOI] [PubMed] [Google Scholar]
- 62.Obstarczyk P., Lipok M., Żak A., et al. , “Amyloid fibrils in superstructures–local ordering revealed by polarization analysis of two-photon excited autofluorescence,” Biomater. Sci. 10(6), 1554–1561 (2022). 10.1039/D1BM01768C [DOI] [PubMed] [Google Scholar]
- 63.Rosenblum W. I., “Structure and location of amyloid beta peptide chains and arrays in alzheimer’s disease: new findings require reevaluation of the amyloid hypothesis and of tests of the hypothesis,” Neurobiol. Aging 23(2), 225–230 (2002). 10.1016/S0197-4580(01)00283-4 [DOI] [PubMed] [Google Scholar]
- 64.Bayer-Garner I., Smoller B., “Al amyloidosis is not present as an incidental finding in cutaneous biopsies of patients with multiple myeloma,” Clin. Exp. Dermatol. 27(3), 240–242 (2002). 10.1046/j.1365-2230.2002.01022.x [DOI] [PubMed] [Google Scholar]
- 65.Horobin R., James N., “The staining of elastic fibres with direct blue 152. a general hypothesis for the staining of elastic fibres,” Histochem. Cell Biol. 22(4), 324–336 (1970). 10.1007/BF00277460 [DOI] [PubMed] [Google Scholar]
- 66.Horobin R., Flemming L., “Structure-staining relationships in histochemistry and biological staining: Ii. mechanistic and practical aspects of the staining of elastic fibres,” J. Microsc. 119(3), 357–372 (1980). 10.1111/j.1365-2818.1980.tb04107.x [DOI] [PubMed] [Google Scholar]
- 67.Lendrum A., Slidders W., Fraser D., “Renal hyalin: a study of amyloidosis and diabetic fibrinous vasculosis with new staining methods,” J. Clin. Pathol. 25(5), 373–396 (1972). 10.1136/jcp.25.5.373 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Westermark G., Johnson K., Westermark P., “Staining methods for identification of amyloid in tissue,” in Methods in Enzymology , vol. 309 (Academic Press, 1999), pp. 3–25. [DOI] [PubMed] [Google Scholar]
- 69.He C., He H., Chang J., et al. , “Polarisation optics for biomedical and clinical applications: a review,” Light:Sci. Appl. 10(1), 194 (2021). 10.1038/s41377-021-00639-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Wolman M., “Polarized light microscopy as a tool of diagnostic pathology,” J Histochem Cytochem. 23(1), 21–50 (1975). 10.1177/23.1.1090645 [DOI] [PubMed] [Google Scholar]
- 71.Tuchin V. V., “Polarized light interaction with tissues,” J. Biomed. Opt. 21(7), 071114 (2016). 10.1117/1.JBO.21.7.071114 [DOI] [PubMed] [Google Scholar]
- 72.Changoor A., Tran-Khanh N., Méthot S., et al. , “A polarized light microscopy method for accurate and reliable grading of collagen organization in cartilage repair,” Osteoarthritis and cartilage 19(1), 126–135 (2011). 10.1016/j.joca.2010.10.010 [DOI] [PubMed] [Google Scholar]
- 73.Westreich J., Khorasani M., Jones B., et al. , “Novel methodology to image stromal tissue and assess its morphological features with polarized light: towards a tumour microenvironment prognostic signature,” Biomed. Opt. Express 10(8), 3963–3973 (2019). 10.1364/BOE.10.003963 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74.Ramella-Roman J. C., Novikova T., Polarized Light in Biomedical Imaging and Sensing: Clinical and Preclinical Applications (Springer, 2022). [Google Scholar]
- 75.Yang X., Bai B., Zhang Y., et al. , “Virtual birefringence imaging and histological staining of amyloid deposits in label-free tissue using autofluorescence microscopy and deep learning,” Nat. Commun. 15(1), 7978 (2024). 10.1038/s41467-024-52263-z [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Borovkova M., Sieryi O., Lopushenko I., et al. , “Screening of alzheimer’s disease with multiwavelength stokes polarimetry in a mouse model,” IEEE Trans. Med. Imaging 41(4), 977–982 (2022). 10.1109/TMI.2021.3129700 [DOI] [PubMed] [Google Scholar]
- 77.Borovkova M., Bykov A., Popov A., et al. , “Evaluating β-amyloidosis progression in alzheimer’s disease with mueller polarimetry,” Biomed. Opt. Express 11(8), 4509–4519 (2020). 10.1364/BOE.396294 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Qiu Y., Jin T., Mason E., et al. , “Predicting thioflavin fluorescence of retinal amyloid deposits associated with alzheimer’s disease from their polarimetric properties,” Trans. Vis. Sci. Tech. 9(2), 47 (2020). 10.1167/tvst.9.2.47 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Feldman A. T., Wolfe D., “Tissue processing and hematoxylin and eosin staining,” in Histopathology , vol. of Methods in Molecular Biology1180 (Humana Press, 2014), pp. 31–43. [DOI] [PubMed] [Google Scholar]
- 80.Reinhard E., “High dynamic range imaging,” in Computer Vision: A Reference Guide , (Springer, 2020), pp. 1–6. [Google Scholar]
- 81.Goldstein D. H., Polarized Light (CRC Press, 2017), 3rd ed. [Google Scholar]
- 82.Nelson S. A., Interference phenomena, compensation, and optic sign , Tulane Univ. Mineral; pp. 1–19 (2014). [Google Scholar]
- 83.Barron L. D., Molecular Light Scattering and Optical Activity (Cambridge University Press, 2009), 2nd ed. [Google Scholar]
- 84.Kumar J., Era na H., López-Martínez E., et al. , “Detection of amyloid fibrils in parkinson’s disease using plasmonic chirality,” Proc. Natl. Acad. Sci. 115(13), 3225–3230 (2018). 10.1073/pnas.1721690115 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Kolodziejczyk A., Nafie L. A., Wajda A., et al. , “Exceptionally enhanced raman optical activity (roa) of amyloid fibrils and their prefibrillar states,” Chem. Commun. 59(72), 10793–10796 (2023). 10.1039/D3CC03216G [DOI] [PubMed] [Google Scholar]
- 86.Majka Z., Kwiecień K., Kaczor A., “Vibrational optical activity of amyloid fibrils,” ChemPlusChem 89(8), e202400091 (2024). 10.1002/cplu.202400091 [DOI] [PubMed] [Google Scholar]
- 87.Kelenyi G., “Thioflavin s fluorescent and congo red anisotropic stainings in the histologic demonstration of amyloid,” Acta Neuropathol. 7(4), 336–348 (1967). 10.1007/BF00688089 [DOI] [PubMed] [Google Scholar]
- 88.Rodríguez-Nú nez O., Novikova T., “Polarimetric techniques for the structural studies and diagnosis of brain,” Adv. Opt. Technol. 11(5-6), 157–171 (2022). 10.1515/aot-2022-0015 [DOI] [Google Scholar]
- 89.Ushenko A. G., Sdobnov A., Soltys I. V., et al. , “Insights into polycrystalline microstructure of blood films with 3d mueller matrix imaging approach,” Sci. Rep. 14(1), 13679 (2024). 10.1038/s41598-024-63816-z [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90.Rubinsztein-Dunlop H., Forbes A., Berry M., et al. , “Roadmap on structured light,” J. Opt. 19(1), 013001 (2017). 10.1088/2040-8978/19/1/013001 [DOI] [Google Scholar]
- 91.Bliokh K. Y., Karimi E., Padgett M. J., et al. , “Roadmap on structured waves,” J. Opt. 25(10), 103001 (2023). 10.1088/2040-8986/acea92 [DOI] [Google Scholar]
- 92.Meglinski I., Novikova T., Dholakia K., “Polarization and orbital angular momentum of light in biomedical applications: Feature issue introduction,” Biomed. Opt. Express 12(10), 6255–6258 (2021). 10.1364/BOE.442828 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Meglinski I., Lopushenko I., Sdobnov A., et al. , “Orbital angular momentum of light in scattering medium,” Optics Photonics News 35, 43 (2024). [Google Scholar]
- 94.Meglinski I., Lopushenko I., Sdobnov A., et al. , “Phase preservation of orbital angular momentum of light in multiple scattering environment,” Light:Sci. Appl. 13(1), 214 (2024). 10.1038/s41377-024-01562-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 95.Khanom F., Mohamed N., Lopushenko I., et al. , “Twists through turbidity: propagation of light carrying orbital angular momentum through a complex scattering medium,” Sci. Rep. 14(1), 20662 (2024). 10.1038/s41598-024-70954-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96.Sarenac D., Kapahi C., Silva A. E., et al. , “Direct discrimination of structured light by humans,” Proc. Natl. Acad. Sci. 117(26), 14682–14687 (2020). 10.1073/pnas.1920226117 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.Sarenac D., Silva A. E., Kapahi C., et al. , “Human psychophysical discrimination of spatially dependent pancharatnam-berry phases in optical spin-orbit states,” Sci. Rep. 12(1), 3245 (2022). 10.1038/s41598-022-07089-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Pushin D. A., Cory D. G., Kapahi C., et al. , “Structured light enhanced entoptic stimuli for vision science applications,” Front. Neurosci. 17, 1232532 (2023). 10.3389/fnins.2023.1232532 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 99.Pushin D., Kapahi C., Silva A., et al. , “Psychophysical discrimination of radially varying polarization-based entoptic phenomena,” Phys. Rev. Appl. 21(1), L011002 (2024). 10.1103/PhysRevApplied.21.L011002 [DOI] [Google Scholar]
- 100.Pushin D. A., Garrad D. V., Kapahi C., et al. , “Characterizing the circularly-oriented macular pigment using spatiotemporal sensitivity to structured light entoptic phenomena,” arXiv (2024). 10.48550/arXiv.2409.04416 [DOI] [PMC free article] [PubMed]
- 101.Kapahi C., Silva A. E., Cory D. G., et al. , “Measuring the visual angle of polarization-related entoptic phenomena using structured light,” Biomed. Opt. Express 15(2), 1278–1287 (2024). 10.1364/BOE.507519 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 102.Sarenac D., Cory D., Nsofini J., et al. , “Generation of a lattice of spin-orbit beams via coherent averaging,” Phys. Rev. Lett. 121(18), 183602 (2018). 10.1103/PhysRevLett.121.183602 [DOI] [PubMed] [Google Scholar]
- 103.Schwarz S., Kapahi C., Xu R., et al. , “Talbot effect of orbital angular momentum lattices with single photons,” Phys. Rev. A 101(4), 043815 (2020). 10.1103/PhysRevA.101.043815 [DOI] [Google Scholar]
- 104.Cameron A. R., Cheng S. W., Schwarz S., et al. , “Remote state preparation of single-photon orbital-angular-momentum lattices,” Phys. Rev. A 104(5), L051701 (2021). 10.1103/PhysRevA.104.L051701 [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data is included in the manuscript and/or supporting information.