Abstract
Pulse oximetry was used to detect return of pulsatile flow in 27 subjects during reactive hyperaemia following 3 min of total limb ischaemia induced by above knee tourniquet occlusion. Fourteen patients with exercise induced leg pain had 18 symptomatic limbs tested. Thirteen controls had 25 limbs tested. Return of pulsatile flow during reactive hyperaemia occurred within 20 s of tourniquet release in the 25 control limbs which was then regarded as normal. The mean time for return of pulsatile flow in 18 symptomatic limbs was 53 +/- 37 s (P < 0.05 versus controls). Three limbs had a normal value, two of which did not have peripheral vascular disease. Pulse oximetry correctly identified all 25 asymptomatic limbs and 15 of 16 patients with claudication secondary to peripheral vascular disease (PVD). This modification of the reactive hyperaemia test using the pulse oximeter is simple and quick to perform. It has potential as a non-invasive screening test for PVD, suitable for outpatient assessment.
Full text
PDF

Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Baker J. D. Poststress Doppler ankle pressures: a comparison of treadmill exercise with two other methods of induced hyperemia. Arch Surg. 1978 Oct;113(10):1171–1173. doi: 10.1001/archsurg.1978.01370220057009. [DOI] [PubMed] [Google Scholar]
- Bernstein E. F., Fronek A. Current status of noninvasive tests in the diagnosis of peripheral arterial disease. Surg Clin North Am. 1982 Jun;62(3):473–487. doi: 10.1016/s0039-6109(16)42739-8. [DOI] [PubMed] [Google Scholar]
- Fronek A., Coel M., Bernstein E. F. The pulse-reappearance time: an index of over-all blood flow impairment in the ischemic extremity. Surgery. 1977 Apr;81(4):376–381. [PubMed] [Google Scholar]
- Johnson W. C. Doppler ankle pressure and reactive hyperemia in the diagnosis of arterial insufficiency. J Surg Res. 1975 Feb;18(2):177–180. doi: 10.1016/0022-4804(75)90013-x. [DOI] [PubMed] [Google Scholar]
- Joyce W. P., Walsh K., Gough D. B., Gorey T. F., Fitzpatrick J. M. Pulse oximetry: a new non-invasive assessment of peripheral arterial occlusive disease. Br J Surg. 1990 Oct;77(10):1115–1117. doi: 10.1002/bjs.1800771013. [DOI] [PubMed] [Google Scholar]
- Lawson D., Norley I., Korbon G., Loeb R., Ellis J. Blood flow limits and pulse oximeter signal detection. Anesthesiology. 1987 Oct;67(4):599–603. doi: 10.1097/00000542-198710000-00032. [DOI] [PubMed] [Google Scholar]
- Mahler F., Koen L., Johansen K. H., Bernstein E. F., Fronek A. Postocclusion and postexercise flow velocity and ankle pressures in normals and marathon runners. Angiology. 1976 Dec;27(12):721–729. doi: 10.1177/000331977602701207. [DOI] [PubMed] [Google Scholar]
- Nowak G. S., Moorthy S. S., McNiece W. L. Use of pulse oximetry for assessment of collateral arterial flow. Anesthesiology. 1986 Apr;64(4):527–527. doi: 10.1097/00000542-198604000-00028. [DOI] [PubMed] [Google Scholar]