Effect of Direct Versus Indirect Bonding Techniques on Fixed Retainer Failure Rates: A Systematic Review and Meta-Analysis

Mohamed A Marei 1,, Lujain E Failakawi 2, Fatemah Y Alhouti 2, Mohammed Y Alshamly 1, Omar Yousry Mostafa 3
Editors: Alexander Muacevic, John R Adler
PMCID: PMC12958396  PMID: 41788127

Abstract

Bonded fixed orthodontic retainers frequently fail, yet it remains uncertain whether laboratory-based indirect bonding, including computer-aided design and computer-aided manufacturing (CAD/CAM)-assisted techniques, reduces failure rates compared with conventional chair-side direct bonding. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochrane Library, Dentistry & Oral Science Source, Google Scholar, ClinicalTrials.gov, and other trial registers were searched from inception to November 2025. Randomized controlled trials (RCTs) and prospective or retrospective cohort studies comparing indirect with direct bonding and reporting retainer failure were eligible. Two reviewers independently screened studies, extracted data, and assessed risk of bias using the Revised Cochrane Risk of Bias tool for randomized trials (RoB 2) for randomized trials and the Newcastle-Ottawa Scale (NOS) for cohort studies. Hazard ratios (HRs) for first failure were pooled using a random-effects model, and heterogeneity was quantified with the I² statistic. The protocol was registered in the International Prospective Register of Systematic Reviews (PROSPERO; registration number: CRD420251003540). Fifteen studies, including 13 RCTs and two cohort studies involving 1,481 patients, were included. The pooled analysis for mandibular retainers demonstrated a significantly higher failure risk in the direct bonding group (HR = 1.41, 95% CI 1.12-1.79, p = 0.004), with low heterogeneity (I² = 14%). For maxillary retainers, no statistically significant difference was observed between bonding techniques (HR = 1.28, 95% CI 0.90-1.84, p = 0.17). Overall risk of bias was low to moderate, with inadequate blinding being the most common limitation. Updated evidence indicates a significantly higher failure risk for directly bonded mandibular retainers compared with indirect bonding, while outcomes for maxillary retainers appear comparable between techniques. Indirect bonding may therefore offer improved mandibular retainer survival, although further well-controlled trials are required to confirm this effect.

Keywords: bonding, failure rate, fixed lingual bonded retainer, fixed retainer, indirect bonding

Introduction and background

Maintaining the results of orthodontic treatment poses a longstanding clinical challenge due to the natural tendency of teeth to relapse. Relapse is largely attributed to persistent periodontal fiber tension and muscular imbalance, which persist even after active treatment [1]. To counteract these forces and stabilize the dentition, various types of retainers have been developed, with fixed retainers, particularly the mandibular 3-3 bonded retainer, being among the most commonly employed due to their effectiveness and low reliance on patient compliance [2]. Traditionally, the direct bonding technique has been the preferred method for placing fixed retainers. This approach involves chairside placement of the retainer wire and composite application directly onto the teeth. In contrast, the indirect bonding technique involves laboratory-based preparation where the wire and composite pads are first positioned on a cast before being transferred to the patient’s mouth via a transfer tray. Advocates of the indirect method suggest it offers greater precision, shorter chairside time, and improved isolation, though its impact on clinical failure rates remains uncertain [3]. Despite the widespread use of both techniques, bond failure remains a frequent complication, often necessitating retreatment and raising concerns about long-term stability. While some studies suggest improved outcomes with indirect bonding due to controlled placement and enhanced moisture control, others report similar or higher failure rates compared to direct techniques [4]. These inconsistencies have created ambiguity regarding the optimal bonding approach.

In addition to technique-related factors, the bonding protocol itself may influence retainer survival. Variations in enamel preparation, etching concentration and duration, primer composition, and adhesive systems have been shown to affect bonding performance. Differences in enamel conditioning and adhesive systems have been shown to affect rebonding success and may therefore influence retainer survival. Laboratory-based indirect bonding, including computer-aided design and computer-aided manufacturing (CAD/CAM)-assisted workflows, may allow better control over composite placement and moisture isolation, which could partly explain differences in reported failure rates. Although previous systematic reviews have compared the effectiveness of different retainer designs and materials, few have focused specifically on failure rates associated with bonding techniques across both arches, including newer CAD/CAM-based systems. Therefore, the present systematic review and meta-analysis aimed to evaluate the failure rates of mandibular and maxillary fixed retainers placed using direct versus indirect bonding techniques. By synthesizing evidence from clinical studies, this review aims to clarify whether one technique demonstrates superior clinical performance and to provide evidence-based guidance for orthodontic retention protocols [5]. Unlike previous reviews, this study incorporates time-to-event analysis and includes contemporary CAD/CAM retainers.

Review

Methods

Protocol and Registration

This meta-analysis was registered on the International Prospective Register of Systematic Reviews (PROSPERO; registration number: CRD420251003540). This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [6] to ensure that the review was done in a clear and organized way. We also updated the PROSPERO record to match the final review process.

Eligibility Criteria and Review Question 

The research question was formulated using the Population, Intervention, Comparator, Outcome (PICO) framework [7]. The population included patients who had completed orthodontic treatment and received a fixed retainer. The intervention was the indirect bonding technique for placement of the retainer; the comparator was the direct bonding technique. The outcome assessed was the failure rate of the fixed retainer. In this Review, we included both randomized clinical trials, randomized controlled trials (RCTs) and cohort studies.

Information Sources and Search Strategy

An electronic database search was done, including PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL) Plus (EBSCO), Cochrane Library, Dentistry & Oral Science Source, and the Trials Meta Register, up to November 2025. The search strategy used a combination of MeSH terms and Boolean operators so that relevant studies could be obtained. Also, a manual search was performed using Google Scholar and ClinicalTrials.gov, applying the same MeSH-based strategy. The full electronic search strategy is provided in Appendix A.

Study Selection Process

RCTs and prospective or retrospective cohort studies that reported the failure rates as outcomes were included. All search results were imported into the Rayyan software (Qatar Computing Research Institute (QCRI), Hamad Bin Khalifa University, Doha, Qatar) for screening. The study selection process was done in two phases by two independent reviewers (MM and MA). First, titles and abstracts were screened to exclude irrelevant studies. Then, the full texts of studies were reviewed for final inclusion. The final included studies were imported into Zotero (Corporation for Digital Scholarship, Vienna, VA) for citation.

Data Collection Process

Study screening and data extraction were performed independently by two reviewers, with disagreements resolved by consensus. Inter-rater agreement was assessed and is now reported to enhance transparency. Data extraction included the following items: author, year, study design, sample size, follow-up duration, etchant/adhesive used, type of retainer wire, failure rate results, and corresponding p-values and hazard ratios (HRs), reported or calculated when not provided directly. The extracted data were checked more than once for accuracy, and any discrepancies were resolved by re-reviewing the original studies.

Risk of Bias Assessment

The Cochrane Collaboration’s tool [8] was used by two authors to assess the risk of bias in the included studies (RCTs). This tool covers several key domains. After answering the questions for each domain, each study was rated as having a low, unclear, or high risk of bias. The Newcastle-Ottawa Scale (NOS) [9] was used for the cohort studies.

Statistical Analysis

In this meta-analysis, the retainer failure was assessed using failure rates and HRs. For each included study, we extracted the reported HR and its 95% confidence interval (CI) whenever available. When HRs were not reported, they were approximated from binary outcome data using established methods; these estimates assume proportional hazards and should be interpreted cautiously. This approach has been previously used in similar orthodontic and implant survival meta-analyses, as in the study by Tierney et al. [10]. 

Heterogeneity among studies was assessed using the I² statistic to evaluate differences in effect estimates. The meta-analysis was conducted for studies with available quantitative data using Review Manager (RevMan) version 5.3 (The Cochrane Collaboration, 2020, London, UK). Due to variations in follow-up durations across the included studies, a random-effects model was applied to account for potential heterogeneity.

Results

Study Selection and Characteristics

The database was searched, and a total of 1,013 records were initially obtained. After removing duplicates, 983 studies were left. Title and abstract screening were done, which resulted in the exclusion of 963. Following a full-text assessment based on predefined inclusion and exclusion criteria, 15 studies were decided to be included in the final analysis. Thirteen studies [4,11-22] were RCTs, and two were prospective cohort studies [23,24]. Figure 1 shows the PRISMA flowchart which outlines the study selection process. A total of 1,481 patients were included in this meta-analysis. All included studies assessed the failure rates of mandibular fixed retainers, while only four studies [11,17,18,24] reported on failure rates of maxillary retainers using both direct and indirect bonding techniques.

Figure 1. PRISMA flow diagram illustrating the study selection process for studies comparing direct versus indirect bonding of fixed orthodontic retainers, adapted according to PRISMA guidelines .

Figure 1

Source: [6]

A total of 15 studies compared the failure rates of indirect versus direct bonding for the mandibular arch (Table 1). The pooled analysis demonstrated a statistically significant difference between the two techniques, with a combined hR of 1.41 (95% CI: 1.12-1.79), p = 0.004. This indicates that directly bonded mandibular retainers have a higher risk of failure compared with those bonded indirectly. Figure 2 shows the forest plot of the included studies. Appendix B provides additional methodological detail supporting the summary of included studies.

Table 1. Characteristics of included studies comparing direct and indirect bonding techniques for fixed orthodontic retainers, including study design, sample size, follow-up duration, failure rates, hazard ratios, and statistical significance for mandibular and maxillary retainers.

RCT: randomized controlled trial

Author/ study design Retainer wire for direct bonding Retainer wire for indirect bonding Etchant for direct bonding Etchant for indirect bonding Adhesive for direct bonding Adhesive for indirect bonding
Jowett et al. [11] / RCT 0.039 × 0.014-inch rectangular wire Nickel-titanium (nitinol) 35% phosphoric acid Same Transbond XT Primer + Transbond LR Same
Gera et al. [17] / RCT 0.0215-inch six-stranded stainless steel 0.014 × 0.014-inch rectangular nitinol 37% phosphoric acid Same Transbond XT + Tetric Flow Same
Bovali et al. [4] / RCT 0.0215-inch multistrand stainless steel wire Same 35% phosphoric acid 35% phosphoric acid Transbond XT Primer + Transbond LR Maximum Cure A & B
Gelin et al [20] / RCT 0.0175-inch, 6-strand twisted stainless steel (Memotain®) 0.014 × 0.014-inch 37% phosphoric acid Same Transbond XT + Transbond LR Same
Egli et al. [15] / RCT 0.0215-inch multistranded stainless steel Same Not reported Not reported Transbond XT + Transbond LR Maximum Cure A & B (Reliance)
Gunay and Oz [12] / RCT 0.0195-in dead-soft coaxial wire 0.0175-in 6-strand multistranded stainless steel wire 32% phosphoric acid Same Transbond XT + Transbond LR Same
Pullisaar et al. [18] / RCT 0.0215-inch 6-stranded stainless steel 0.014 × 0.014-inch nitinol (nickel-titanium) Not specified (likely phosphoric acid) Same Not specified (likely standard protocol) Same
Shim et al. [13] / RCT Multistranded stainless steel Same 35% phosphoric acid Same Assure Plus + FlowTain Same
Cornelis et al. [16] / RCT 0.0215-inch multistranded stainless steel wire Same Not reported Not reported Transbond LR Maximum Cure A & B (Reliance)
Çokakoğlu S, Kızıldağ [19] / RCT 0.0215" 5-strand stainless steel Same Not reported Not reported Transbond LR / Ortho Connect Flow Maximum Cure / Ortho Connect Flow
Murugaiyan et al. [24] / prospective 0.0155-inch (0.40 mm) 6-stranded stainless steel 0.5 × 0.3 mm cobalt-chromium CAD 37% phosphoric acid Same Ortho Solo + NexcompFlow Same
Taner and Aksu [23] / prospective   0.016 × 0.022 inch Same 37% phosphoric acid 37% phosphoric acid Transbond XT + LR Maximum Cure A & B
Kartal et al. [14] / RCT 0.0215 in 5-strand stainless steel coaxial 0.014 × 0.014 in nickel–titanium 37% phosphoric acid Same Transbond XT Primer + LR Same
Tran et al. [21] / RCT Ortho-FlexTech (0.974 × 0.402 mm) 3-strand stainless steel wire (0.5 mm 35% phosphoric acid Same Assure Plus + FlowTain Same
Johal et al. [22] / RCT 0.0383-in by 0.0158-in Ortho FlexTech retainer wire AND 0.025-in Blu-Elgiloy 0.0215-in multistranded gold-plated 37% phosphoric acid etching Same Transbond XT primer Same

Figure 2. Forest plot for the lower arch.

Figure 2

This forest plot compares the failure risk of mandibular fixed retainers bonded using indirect versus direct techniques. Individual study hazard ratios were derived from included randomized and cohort studies [4,11–24].

Individual study estimates varied, with some reporting higher failure rates for direct bonding (e.g., Murugaiyan et al. (2024) [24], HR: 5.26 (0.25-109.52)), while others favored indirect bonding (e.g., Kartal et al. (2021) [14], HR: 0.86 (0.29-2.56)). Despite this variability, heterogeneity across the studies was low (chi-square = 16.32, df = 14, P = 0.29; I² = 14%), indicating good consistency in the overall results.

A total of four studies [9,15,16,21] evaluated the failure risk of indirect (CAD/CAM) versus direct (conventional) retainers in the maxillary arch. Using a random-effects model, the pooled analysis showed no statistically significant difference between the techniques, with a combined HR of 1.30 (95% CI: 0.89-1.90), p = 0.18.

Heterogeneity among these maxillary studies was low (chi² = 3.22, df = 3, P = 0.36; I² = 7%), suggesting consistent findings across the included trials. Figure 3 displays the forest plot for maxillary retainers.

Figure 3. Forest plot for the upper arch.

Figure 3

This forest plot compares the failure risk of maxillary fixed retainers bonded using indirect versus direct techniques, based on included clinical studies [11,17,18,24].

Results of Individual Studies

In this meta-analysis, the retainer failure was assessed using failure rates and HRs. For each included study, we extracted the reported HR and its 95% CI whenever available.

Four studies [11,15,17,18] reported HRs directly, while 11 [4,12-14,16,19-24] studies provided only binary outcome data at a fixed follow-up and required HR estimation. 

Jowett et al.'s study (2023) [11] was terminated early due to a high failure rate in the indirect group (Memotain®). The failure rate for the indirect retainer of the upper (Memotain®) was 50%, and there was a 17% failure rate with the direct (Ortho-FlexTech™), and this was statistically significant. The HR was 2.82 (95% CI: 1.00-7.99; P = 0.019). The direct group (Memotain®) failure rate showed that there was a significantly increased risk of failure in the maxillary arch. In the mandibular arch, failure rates were 35% in the indirect group (Memotain®) and 28% for the direct group (Ortho-FlexTech™), but the difference was not statistically significant (HR = 1.51, 95% CI: 0.57-3.99; P = 0.53).

Gera et al.'s (2023) [17] failure rate was 22% of maxillary retainers for both direct and indirect groups, and approximately 30% of lower retainers for the indirect group and 29% for direct. However, this difference in the failure rate was not statistically significant in either the upper or lower arch. The reported HRs indicated that there is no statistically significant difference in survival between the two groups: the HR for the upper arch was 0.99 (95% CI: 0.52-1.90; P = 0.99), and for the lower arch it was 0.93 (95% CI: 0.53-1.63; P = 0.80).

In the study by Bovali et al. (2014) [4], the failure occurred in 32% of the indirect group and 24% of the direct group. This difference in the failure rate between the two groups was not statistically significant (P = 0.35). HRs were not reported in this study. We approximated the HR using the log odds ratio (OR) method; the estimated HR was 1.50 (95% CI: 0.48-4.68), indicating that there is no statistically significant difference in failure risk between the two groups.

In Gelin et al.'s study (2020) [20], the failure rate was 52.6% for the indirect group (CAD/CAM) and 40.9% for the direct group. Although HRs were not reported, we calculated an approximate HR using the log OR method; the estimated HR was 1.61 (95% CI: 0.47-5.54), indicating that there is no statistically significant difference in failure risk between the two groups.

In the study by Egli et al. (2017) [15], the failure rate was 43% for the indirect group and 37% for the direct group. And this difference was not statistically significant (P = 0.59). The HR was reported as 1.26 (95% CI: 0.56-2.81; P = 0.58), indicating that there is no significant difference in failure risk between the bonding techniques.

In the study by Gunay and Ozv (2018) [12], the failure rate was 13.2% in the stainless steel group and 18.9% in the dead-soft group, with no statistically significant difference between the two groups (P = 0.597). Although HRs were not reported, we calculated an approximate HR using the log OR method; the estimated HR was 1.43 (95% CI: 0.54-3.75), indicating that there is no statistically significant difference in failure risk between the two groups. Both groups used direct bonding; the stainless steel wire was fabricated on a study model and transferred to the mouth using a silicon key, so it’s considered semi-direct, while the dead-soft wire was shaped and bonded directly in the mouth, which may confound the interpretation of wire performance.

In the study by Pullisaar et al. (2024) [18], in the maxillary arch, the failure rate was 34% for the indirect group (CAD/CAM) and 38% for the direct group (conventional retainers). In the mandibular arch, the failure rate was 42% for the indirect group (CAD/CAM) and 40% for the conventional direct group. This difference was not statistically significant. The reported HR = 1.20 (95% CI: 0.74-1.95; P = 0.46) in the maxillary arch and HR = 0.98 (95% CI: 0.62-1.56; P = 0.94) in the mandibular arch, indicating that there is no significant difference in failure risk between the two groups.

Shim et al.'s study (2022) [13] was a three-arm RCT. The failure rates were 25% for CAD/CAM, 43.8% for lab-based, and 14.3% for traditional retainers. For meta-analysis purposes, the two conventional groups were combined, so the failure rate was 30%. The HRs were not reported, so we calculated an approximate HR using the log odds ratio method. The estimated HR was 2.00 (95% CI: 0.31-13.05), indicating that there is no statistically significant difference in failure risk between the two groups.

As reported by Cornelis et al. (2022) [16], the failure rate was 54% in both the direct and indirect groups. The authors reported no statistically significant difference in survival between the groups, with an HR of 1.09 (95% CI: 0.26-4.60; P = 0.91).

In the study by Çokakoğlu and Kızıldağ et al. (2023) [19], the failure rate was 9.1% in the direct group with conventional adhesive and 20% in the indirect bonding group with traditional adhesive. The HRs were not reported; we calculated an approximate HR using the log OR method. The estimated HR was 2.50 (95% CI: 0.43-14.40), indicating no statistically significant difference in failure risk between the two groups.

In the study by Murugaiyan et al. [24] (2024), in the mandibular arch, the failure rate was 20% for the direct group (bonded retainers) and 0% for the indirect (rapid prototype retainers). This difference was not statistically significant (P = 0.38). The HRs were not reported; we calculated them using the log OR method with continuity correction. The estimated HR was 6.88 (95% CI: 0.29-164.8), indicating that there is no statistically significant difference in failure risk between the two groups, and this is due to the wide CI.

In Taner and Aksu et al.'s study (2011) [23], the failure rate was 46.9% for the direct group and 29.4% for the indirect group. This difference in the failure rate was not statistically significant (P > 0.05). As the HR was not reported, we calculated the HR using the log OR method; the result was 2.11 (95% CI: 0.77-5.79), indicating that there is no significant difference in failure risk between the two groups.

In Kartal et al.'s study (2021) [14], the failure rate was 23% for the indirect (Memotain®) group and 27% for the direct (five-stranded) group. This difference was not statistically significant (P = 0.749). The HRs were not reported, so we calculated them using the log OR method. The estimated HR was 0.82 (95% CI: 0.23-2.89), indicating that there is no significant difference in failure risk between the two groups.

In Tran et al.'s study (2024) [21], the CAD/CAM and lab-based groups both used indirect bonding and were combined for this analysis. The failure rate in the indirect bonding group was 27.6% and 28.6% in the direct bonding (chairside) group. This difference in failure rates was not statistically significant (P = 0.14). An approximate HR was calculated using the log OR method; the calculated HR was 1.05 (95% CI: 0.25-4.35), indicating that there is no significant difference in failure risk between indirect and direct bonding techniques.

In the study by Johal et al. (2025) [22], the failure rate was 4% for the direct (Ortho-FlexTech™) group and 19.5% for the indirect groups (multistranded + Blu-Elgiloy). This difference was statistically significant (overall P < 0.001). The HRs were not reported for a direct-indirect comparison, so we calculated them using a pooled weighted method. The estimated HR was 0.14, indicating a markedly lower failure risk with direct bonding, although the statistical significance of this pooled estimate cannot be confirmed.

Risk of Bias Results

Overall, the included RCTs demonstrated low to moderate risk of bias across most domains (Figure 4), indicating generally acceptable methodological quality. The risk of bias related to missing outcome data and selective reporting was low in the majority of studies, while limitations were primarily related to blinding procedures.

Figure 4. Risk-of-bias summary for included randomized controlled trials, assessed using the the Revised Cochrane Risk of Bias tool for randomized trials (RoB 2) .

Figure 4

Source: [8]

Random sequence generation was judged to be at low risk in 12 studies, with one study assessed as high risk, suggesting a potential limitation in its randomization process. Allocation concealment was rated as low risk in 11 studies, while two studies [12,19] provided insufficient information, resulting in an unclear judgment. Blinding of participants and personnel (performance bias) and blinding of outcome assessment (detection bias) showed greater variability: 11 studies were at low risk for performance bias, and nine studies were at low risk for detection bias. A small number of trials, including ones by Bovali et al. (2014) [4], Gelin et al (2020) [20], and Shim et al. (2022) [13], were judged to have a high risk of bias in these domains due to the absence of blinding.

Incomplete outcome data were considered high risk in four studies, whereas the remaining trials were rated as unclear because of limited reporting on follow-up completeness or attrition. Selective reporting bias was assessed as low risk in nine studies, with the remainder judged as unclear owing to insufficient information on pre-specified outcomes or reporting transparency.

For the cohort studies, Murugaiyan et al. (2024) [24] demonstrated a low risk of bias, while Taner and Aksu (2011) [23] were judged to have a moderate risk of bias, primarily due to non-randomized allocation and limited control for confounding factors (Table 3). Cohort studies were evaluated separately from RCTs.

Table 2. Quality assessment of cohort studies using the Newcastle-Ottawa scale.

Study Selection (max 4) Comparability (max 2) Outcome (max 3) Total (max 9) Risk of bias
Murugaiyan et al. [24] ★★★★ ★★ ★★★ 9 Low
Taner & Aksu [23] ★★★ ★★ 6 Moderate

Discussion

The meta-analysis included 15 mandibular datasets and demonstrated a statistically significant difference between bonding techniques. Indirect bonding showed superior survival, with a pooled HR of 1.41 (95% CI: 1.12-1.79; p = 0.004). Heterogeneity was low (I² = 14%), indicating that the direction and magnitude of the effect were consistent across studies despite variations in follow-up duration, wire type, and adhesive protocols. [25]

These findings suggest that indirect bonding-whether laboratory-prepared or CAD/CAM-assisted-may provide more reliable outcomes for mandibular fixed retainers. Improved pad adaptation, more controlled composite placement, and better isolation during bonding may contribute to this advantage, and for maxillary retainers, the HR was 1.30 (95% CI: 0.89-1.90), p = 0.18). Statistical heterogeneity was low (I² = 14% mandibular; 7% maxillary), supporting the consistency of findings across studies.

These results are consistent with multiple studies reporting no significant difference in failure rates between bonding techniques. For example, Gera et al. (2023) [17] and Gelin et al. (2020) [20] found similar survival outcomes regardless of the technique used. Notably, Jowett et al. (2023) [11] identified a significantly higher failure rate for indirectly bonded Memotain® retainers in the maxillary arch, though such findings were not replicated consistently across the broader dataset. This variability highlights that technique alone may not be the primary determinant of retainer longevity.

Several factors may explain the comparable outcomes observed. Both direct and indirect bonding methods rely heavily on operator skills, material properties, and patient compliance [26]. Although indirect bonding theoretically offers greater precision and reduced chair time, the additional laboratory steps introduce opportunities for technical errors. Conversely, direct bonding, while potentially more prone to in-situ variability, allows real-time adjustments by the clinician.

Importantly, not all indirect bonding techniques in the included studies were CAD/CAM-based, and some CAD/CAM retainers were bonded directly. Therefore, caution should be exercised when interpreting indirect bonding as synonymous with CAD/CAM technology. Future subgroup analyses focused on CAD/CAM versus traditional wire retainers may yield more granular insights into material performance.

From a clinical standpoint, the demonstrated advantage of indirect bonding in the mandible, coupled with comparable outcomes in the maxilla, suggests that both techniques remain acceptable options. Thus, technique selection may reasonably depend on operator preference, workflow, and patient-specific factors instead of being dictated solely by failure rates

However, this meta-analysis has some limitations. First, although most included studies were RCTs with low to moderate risk of bias, blinding of outcome assessment was inconsistently applied. Second, the definition of "failure" varied slightly across studies, and not all studies reported HRs directly; 10 of 15 studies required estimation from binary outcomes data [10]. Third, variations in retainer wire types, adhesives, and follow-up durations introduce some heterogeneity that could not be entirely controlled.

Future research should focus on standardising definitions of retainer failure and ensuring uniform follow-up periods. Additionally, more high-quality RCTs directly comparing different CAD/CAM retainer systems with conventional methods would be valuable, particularly assessing long-term outcomes beyond 24 months.

Conclusions

This meta-analysis demonstrates a significant advantage of indirect bonding for mandibular fixed retainers, with a 41% relative reduction in failure risk compared with direct bonding. In contrast, no significant difference between bonding techniques was observed for maxillary retainers.

Indirect bonding-whether conventional laboratory-based or CAD/CAM-assisted-may therefore offer improved reliability for mandibular retainer placement. Nonetheless, further high-quality, long-term RCTs are needed to confirm these findings and to clarify the performance of different CAD/CAM systems.

Appendices

Appendix A

(Dental[tiab] OR Dentist*[tiab] OR Orthodont*[tiab] OR orthodontic retention[tiab] OR orthodontic retainer[tiab])

AND (Mandibular fixed retainers[tiab] OR mandibular retainers[tiab] OR direct bonded retainer[tiab]

OR indirect bonded retainer[tiab] OR mandibular lingual retainer[tiab] OR "Orthodontic Retainers"[Mesh]

OR retainer failure*[tiab] OR lingual retainer survival[tiab] OR retainer bonding technique[tiab]

OR retainer survival[tiab] OR bonding technique [tiab])

Appendix B

Table 3. Summary of retainer wire types, etching protocols, and adhesive systems used in the direct and indirect bonding groups across the included studies.

Author /study design Sample (n) Follow-up (m) Failure rate for the indirect lower arch   Failure rate for the indirect upper arch   Failure rate for the direct lower  arch Failure rate for the direct upper arch Hazard ratio (HR) for the lower arch Hazard ratio (HR) for the upper arch HR reported or calculated P-value for lower   Significant or non-significant P-value for the upper arch  Significant or non-significant
Jowett et al. [11] / RCT 68 6 m 35%   50% 28% 17%  1.51   2.82 Reported  0.53    NS 0.019 for upper    SS
Gera et al. [17]. / RCT 181 12m 30% 22% 29% 22% 0.93 0.99 Reported 0.8   NS 0.99 for upper   NS
Bovali et al. [4] / RCT 64 6m 32.2% Not reported 24.1% Not reported 1.5 Not reported Calculated 0.35   NS Not reported Not reported
Gelin et al. [20] / RCT 62 12m 32.3% Not reported 29% Not reported 1.11    Not reported Calculated Not reported NS, the author states that it is not statistically significant Not reported Not reported
Egli et al. [15] / RCT 64 24 m              43.3% Not reported 36.7 % Not reported 1.26 Not reported Reported 0.58 NS Not reported Not reported
Gunay and Oz [12] / RCT 120 12m 13.2 % Not reported 18.9 % Not reported 1.43 Not reported Calculated 0.597 NS Not reported Not reported
Pullisaar et al. [18]  / RCT 181 24m 42 % 34% 40 % 38% 0.98 1.2 Reported 0.94 NS 0.46 for upper   NS
Shim et al. [13] / RCT 75 6m 20% Not reported 16.36 % Not reported 1.22   Not reported Calculated 0.045   S Not reported Not reported
Cornelis et al. [16] / RCT 64 60 m 54% Not reported 54% Not reported 1.09 Not reported Calculated 0.91 NS Not reported Not reported
Çokakoğlu and Kızıldağ [19] / RCT 100 12 m 22% Not reported 54% Not reported 2.5 Not reported Calculated 0.459 NS Not reported Not reported
Murugaiyan et al. [24] / Prospective 41 12 m 0%   9.5% 0 % 20% 5.26 2.11 Calculated 0.43   NS 0.38   NS
Taner et al. [23] / Prospective 66 6 m 29.4 % Not reported 46.9% Not reported 1.6 Not reported Calculated  Not reported NS Not reported Not reported
Kartal et al. [14] / RCT 52 6 m   23% Not reported 27% Not reported 0.86 Not reported Calculated 0.749,   NS Not reported Not reported
Tran et al. [22] / RCT 43 24 m 28.8 % Not reported 27.6% Not reported   1.05 Not reported Calculated Not reported NS Not reported Not reported
Johal et al. [22] / RCT 300 24 m    19.5% Not reported 4% Not reported 0.14   Not reported Calculated Not reported S Not reported Not reported

Disclosures

Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:

Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.

Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.

Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.

Author Contributions

Concept and design:  Mohamed A. Marei, Lujain E. Failakawi, Fatemah Y. Alhouti, Mohammed Y. Alshamly, Omar Yousry Mostafa

Acquisition, analysis, or interpretation of data:  Mohamed A. Marei, Lujain E. Failakawi, Fatemah Y. Alhouti, Mohammed Y. Alshamly, Omar Yousry Mostafa

Critical review of the manuscript for important intellectual content:  Mohamed A. Marei, Lujain E. Failakawi, Fatemah Y. Alhouti, Mohammed Y. Alshamly, Omar Yousry Mostafa

Supervision:  Mohamed A. Marei, Lujain E. Failakawi, Fatemah Y. Alhouti, Mohammed Y. Alshamly, Omar Yousry Mostafa

Drafting of the manuscript:  Lujain E. Failakawi, Fatemah Y. Alhouti, Mohammed Y. Alshamly, Omar Yousry Mostafa

References

  • 1.Proffit WR, Fields Jr HW, Sarver DM. Contemporary Orthodontics. St Louis, MO: Mosby Elsevier; Contemporary Orthodontics; pp. 5–2012. [Google Scholar]
  • 2.Long-term periodontal status of patients with mandibular lingual fixed retention. Pandis N, Vlahopoulos K, Madianos P, Eliades T. Eur J Orthod. 2007;29:471–476. doi: 10.1093/ejo/cjm042. [DOI] [PubMed] [Google Scholar]
  • 3.The indirect bonding technique in orthodontics-a narrative literature review. Nawrocka A, Lukomska-Szymanska M. Materials (Basel) 2020;13:986. doi: 10.3390/ma13040986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: a single-center randomized controlled trial comparing placement time and failure over a 6-month period. Bovali E, Kiliaridis S, Cornelis MA. Am J Orthod Dentofacial Orthop. 2014;146:701–708. doi: 10.1016/j.ajodo.2014.08.015. [DOI] [PubMed] [Google Scholar]
  • 5.Effect of direct versus indirect bonding technique on the failure rate of mandibular fixed retainer-a systematic review and meta-analysis. Ahmed A, Fida M, Habib S, Javed F, Ali US. Int Orthod. 2021;19:539–547. doi: 10.1016/j.ortho.2021.09.004. [DOI] [PubMed] [Google Scholar]
  • 6.Key PRISMA 2020 documents. [ Jan; 2026 ]. 2024. https://www.prisma-statement.org https://www.prisma-statement.org
  • 7.The well-built clinical question: a key to evidence-based decisions. Richardson WS, Wilson MC, Nishikawa J, Hayward RS. https://pubmed.ncbi.nlm.nih.gov/7582737/ ACP J Club. 1995;123:0–3. [PubMed] [Google Scholar]
  • 8.The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. Higgins JP, Altman DG, Gøtzsche PC, et al. BMJ. 2011;343:0. doi: 10.1136/bmj.d5928. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. Wells GA, Shea B, O’Connell D, et al. https://www.ohri.ca/programs/clinical_epidemiology/oxford.asp Ottawa Health Research Institute. 2000 [Google Scholar]
  • 10.Practical methods for incorporating summary time-to-event data into meta-analysis. Tierney JF, Stewart LA, Ghersi D, Burdett S, Sydes MR. https://link.springer.com/article/10.1186/1745-6215-8-16. Trials. 2007;8:16. doi: 10.1186/1745-6215-8-16. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial. Jowett AC, Littlewood SJ, Hodge TM, Dhaliwal HK, Wu J. J Orthod. 2023;50:55–68. doi: 10.1177/14653125221118935. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Clinical effectiveness of 2 orthodontic retainer wires on mandibular arch retention. Gunay F, Oz AA. Am J Orthod Dentofacial Orthop. 2018;153:232–238. doi: 10.1016/j.ajodo.2017.06.019. [DOI] [PubMed] [Google Scholar]
  • 13.Comparative assessment of relapse and failure between CAD/CAM stainless steel and standard stainless steel fixed retainers in orthodontic retention patients. Shim H, Foley P, Bankhead B, Kim KB. Angle Orthod. 2022;92:87–94. doi: 10.2319/121720-1015.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Comparative evaluation of periodontal effects and survival rates of Memotain and five-stranded bonded retainers: a prospective short-term study. Kartal Y, Kaya B, Polat-Özsoy Ö. https://link.springer.com/article/10.1007/s00056-020-00243-5. J Orofac Orthop. 2021;82:32–41. doi: 10.1007/s00056-020-00243-5. [DOI] [PubMed] [Google Scholar]
  • 15.Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment stability. A 2-year follow-up of a single-center randomized controlled trial. Egli F, Bovali E, Kiliaridis S, Cornelis MA. Am J Orthod Dentofacial Orthop. 2017;151:15–27. doi: 10.1016/j.ajodo.2016.09.009. [DOI] [PubMed] [Google Scholar]
  • 16.Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: comparison of retainer failures and posttreatment stability. A 5-year follow-up of a single-center randomized controlled trial. Cornelis MA, Egli F, Bovali E, Kiliaridis S, Cattaneo PM. https://www.ajodo.org/article/S0889-5406(16)30649-7/abstract. Am J Orthod Dentofacial Orthop. 2022;162:152–161. doi: 10.1016/j.ajodo.2022.03.014. [DOI] [PubMed] [Google Scholar]
  • 17.Stability, survival, and patient satisfaction with CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 6-month follow-up of a two-centre randomized controlled clinical trial. Gera A, Pullisaar H, Cattaneo PM, Gera S, Vandevska-Radunovic V, Cornelis MA. Eur J Orthod. 2023;45:58–67. doi: 10.1093/ejo/cjac042. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 2-year follow-up of a two-centre randomized controlled trial. Pullisaar H, Cattaneo PM, Gera A, et al. https://academic.oup.com/ejo/article/46/2/cjae006/7613285. Eur J Orthodont. 2002;46:0. doi: 10.1093/ejo/cjae006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Comparison of periodontal status and failure rates with different retainer bonding methods and adhesives: a randomized clinical trial. Çokakoğlu S, Kızıldağ A. Angle Orthod. 2023;93:57–65. doi: 10.2319/031622-224.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: a randomized controlled trial. Gelin E, Seidel L, Bruwier A, Albert A, Charavet C. Korean J Orthod. 2020;50:373–382. doi: 10.4041/kjod.2020.50.6.373. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial. Tran G, Rucker R, Foley P, Bankhead B, Adel SM, Kim KB. Eur J Orthod. 2024;46:79. doi: 10.1093/ejo/cjad079. [DOI] [PubMed] [Google Scholar]
  • 22.A comparison of survival rates using 3 methods of mandibular fixed retainer fabrication: a randomized clinical trial. Johal A, Daly K, Murray D. Am J Orthod Dentofacial Orthop. 2025;168:682–694. doi: 10.1016/j.ajodo.2025.08.005. [DOI] [PubMed] [Google Scholar]
  • 23.A prospective clinical evaluation of mandibular lingual retainer survival. Taner T, Aksu M. Eur J Orthod. 2012;34:470–474. doi: 10.1093/ejo/cjr038. [DOI] [PubMed] [Google Scholar]
  • 24.Post-treatment stability, survival time and periodontal health associated with vacuum-formed, bonded and rapid prototype retainers: A prospective clinical study. Murugaiyan S, Pottipalli Sathyanarayana H, Thakkar D, Padmanabhan S. J Orthod. 2025;52:150–161. doi: 10.1177/14653125241255702. [DOI] [PubMed] [Google Scholar]
  • 25.Measuring inconsistency in meta-analyses. Higgins JP, Thompson SG, Deeks JJ, Altman DG. BMJ. 2003;327:557–560. doi: 10.1136/bmj.327.7414.557. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Retention procedures for stabilising tooth position after treatment with orthodontic braces. Martin C, Littlewood SJ, Millett DT, Doubleday B, Bearn D, Worthington HV, Limones A. https://pmc.ncbi.nlm.nih.gov/articles/PMC10202160/ Cochrane Database Syst Rev. 2023;5:0. doi: 10.1002/14651858.CD002283.pub5. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Cureus are provided here courtesy of Cureus Inc.

RESOURCES