Abstract
Purpose
There is evidence that labor pain and the doses of drugs used to treat it exhibit circadian variation. Previously, we reported that during the night, the effective dose (ED50) of epidural ropivacaine for labor analgesia in 50% of patients was approximately 15% greater than that during the day. However, the influence of time of day on dose requirement at points higher on the dose-response curve is unknown. This double-blinded randomized trial aimed to determine and compare the full dose-response relationship for epidural ropivacaine administered to initiate labor analgesia during the day versus at night.
Patients and Methods
We recruited 150 nulliparous parturients requesting epidural labor analgesia during the day (day group, 07:01–19:00 h) and 150 during the night (night group, 19:01–07:00 h). Within each group, we randomly allocated patients to receive one of six doses of ropivacaine (7.5, 15, 22.5, 30, 37.5, or 45 mg) diluted to 20 mL to initiate epidural analgesia. Effective analgesia was defined as a visual analogue scale pain score of ≤ 3 cm (scale: 0–-10 cm) within 30 min. We generated dose-response curves for ropivacaine using probit regression and estimated the values for ED50 and ED95.
Results
The estimated ED50 value of ropivacaine was greater during the night (22.4 [95% CI 19.9 to 24.8] mg) than during the day (17.9 [95% CI 15.7 to 20.0] mg), and the estimated ED95 value was greater during the night (41.3 [95% CI 36.4 to 48.7] mg) than during the day (32.9 [95% CI 28.9 to 39.0] mg).
Conclusion
The time of day is an important factor that should be considered when selecting the dose of ropivacaine to initiate epidural labor analgesia.
Trial Number and Registry Url
ChiCTR1900025381; https://www.chictr.org.cn/bin/project/edit?pid=42363.
Keywords: pain, labor, analgesia, epidural, anesthetics, local, ropivacaine, dose-response relationship, drug, chronobiology
Introduction
Labor pain perception exhibits circadian variation, with greater pain intensity during the night than during the day.1,2 This can result in a difference in the dose requirement for drugs administered for epidural labor analgesia according to the time of day during which it is requested. In a previous study, in which we used an up-and-down methodology, we reported that the effective dose (ED50) of ropivacaine administered for epidural labor analgesia in 50% of patients was approximately 15% greater during the night than during the day.3 However, ED50 values do not necessarily represent doses that clinicians use in practice, and determination of the effect of time of day on the full dose-response curve for epidural ropivacaine likely has greater clinical relevance because most anesthetists prefer to administer doses greater than the ED50, and differences in drug potency at higher points on the dose-response curve may not be the same as differences at the ED50 level.4
The aim of the present study was to determine and compare the full dose-response relationships for epidural ropivacaine administered to initiate labor analgesia during the day versus during the night using a traditional dose-response methodology. We used probit regression to generate full dose-response curves and to estimate values for ED50 and ED95 during the day and night.
Materials and Methods
Study Design
This was a prospective, double-blinded, two-arm parallel, random-allocation graded dose-response study. The study was approved by the Research Ethics Committee of Hangzhou Women’s Hospital, Hangzhou, China (no. 201901-1) and all participants provided written informed consent to participate. This study was conducted in accordance with the principles of the Declaration of Helsinki. Prior to enrolling parturients, we registered this clinical trial with the Chinese Clinical Trial Registry (ChiCTR1900025381; https://www.chictr.org.cn/bin/project/edit?pid=42363).
We recruited 150 nulliparous parturients requesting epidural analgesia between 07:01- and 19:00 h (day group) and, during the same recruitment period, 150 equivalent patients during the 19:01- and 07:00 h (night group). Inclusion criteria were as follows: age 18–45 years, singleton gestation at 37–41 weeks, body mass index (BMI) ≤ 30 kg.m−2, cervical dilation between 3–5 cm, and American Society of Anesthesiologists (ASA) physical status category II. Exclusion criteria were hypertension, diabetes, obstetric complications or suspected dystocia, allergy to local anesthetics, administration of opioid or sedative drugs in the preceding four hours, known fetal abnormalities, and any contraindication to neuraxial anesthesia. Patients were instructed to use a 10-cm VAS (scale: 0–10 cm) to assess pain at the peak of uterine contractions.
Randomization and Blinding
We randomly allocated patients within each group to receive one of six different doses of epidural ropivacaine (7.5, 15, 22.5, 30, 37.5, or 45 mg). The ropivacaine doses were each diluted to a total volume of 20 mL using sterile normal saline and prepared in identical 20-mL syringes.
Randomization was stratified according to group and performed by an anesthesia assistant using codes generated with Microsoft Excel (Microsoft Corporation, Redmond, WA, USA). Codes were placed in sequentially labelled opaque envelopes, one of which was opened for each patient immediately after enrolment.
Anesthesia Procedure
Upon arrival in the labor room, all parturients received standard monitoring, including non-invasive blood pressure, pulse oximetry, electrocardiography, fetal heart rate, and tocodynamometry. Baseline measurements of blood pressure were recorded, an intravenous cannula was inserted, and 250 mL of warmed lactated Ringer’s solution was infused.
Epidural analgesia was administered to the patient in the left lateral position. After skin disinfection and local anesthetic skin infiltration, the epidural space was located at the estimated L2-3 or L3-4 vertebral interspace with a 17-gauge epidural needle using the loss-of-resistance to saline technique (1–2 mL saline injected). Subsequently, with the orifice of the epidural needle facing cephalad, a wire-reinforced multi-hole catheter was inserted 4–5 cm into the epidural space. After gentle aspiration and checking for the presence of blood or cerebrospinal fluid, the catheter was secured to the patient’s back using a transparent adhesive dressing and tape.
The study drugs were prepared using aseptic precautions by a dedicated assistant who had no further role in the study or clinical care of the patient.
An initial bolus of 5 mL of the study solution was administered as an epidural test dose, followed by a 1-mL saline flush. After confirming the absence of evidence of intrathecal or intravenous injection, the remaining 15 mL of the study drug was administered for approximately two minutes.
Pain scores were recorded at 5-min intervals at the peak of uterine contractions (primary outcome). Simultaneously, maternal blood pressure and heart rate were monitored along with the assessment of the fetal heart rate. The study period was defined as the time interval from administration of the initial dose to 30 min post-dose. An effective response was defined as the achievement of a pain score ≤ 3 cm within the study period. Patients who achieved an effective response had analgesia maintained using ropivacaine 0.1% with sufentanil 0.33 μg/mL. Patients who did not achieve an effective response were administered an additional bolus of 10 mL of 0.2% ropivacaine. If the pain score remained > 3 cm at 15 min after the additional bolus, the epidural catheter was assumed to be non-functional; these patients were excluded from the analysis, their randomization code was reused for the next subsequent patient in that group, and further clinical management was at the discretion of the attending anesthetist.
Secondary study outcomes included sensory block level, motor block assessed using the modified Bromage scale, and side effects, including maternal hypotension (systolic blood pressure < 90 mmHg or < 80% of the baseline value), nausea, vomiting, shivering, pruritus, and fetal bradycardia. Hypotension was treated with intravenous boluses of 50 µg of phenylephrine. We also documented Apgar scores at 1 and 5 min after birth and umbilical arterial pH. The study also documented the incidence of induced labor.
Sample Size Calculation
The sample size was determined empirically based on a similar previously published dose-response study of epidural ropivacaine for labor analgesia.4 The latter study included 15 patients in different epidural ropivacaine dose groups to determine the estimates of ED50 and ED95. However, in that study, the 95% confidence intervals (CIs) for the estimates were wide; therefore, we arbitrarily increased the sample size in our study to 25 patients per dose subgroup to obtain more precise dose estimates.
Statistical Analysis
We used the Kolmogorov–Smirnov test to assess the distribution of data for normality. Variables with a normal distribution are presented as mean (SD) and were compared using the Student’s t-test. Variables with non-normal distribution are presented as median (IQR) and were analyzed using the Mann–Whitney U-test. Categorical data are presented as numbers (%) and were analyzed using the chi-square or Fisher’s exact test, as appropriate.
Dose-response data were analyzed using a probit analysis. In each of the two groups, the number of patients with a positive response in each dose subgroup was tallied and probit transformation was applied. Probit regression was then performed, and the values for ED50 and ED95 with 95% CIs were estimated by interpolation. The relative potency of ropivacaine was compared between groups by estimating the relative mean potency with 95% CIs. Response data for a full range of doses were obtained to generate sigmoidal dose-response curves.
Statistical analyses were performed using IBM SPSS Statistics for Windows (version 22.0; IBM Corp., Armonk, NY, USA) and GraphPad Prism (version 6.0; GraphPad Software, Inc., San Diego, CA, USA). Values of p < 0.05 (two-tailed) were considered statistically significant.
Results
The recruitment flow of patients is shown in Figure 1. Of the 312 parturients assessed for eligibility, 300 participants (150 in the day group and 150 in the night group) were recruited for the study and included in the final analysis. None of the patients were excluded because of inadequate analgesia after receiving the study dose and/or rescue bolus. The patient characteristics are presented in Table 1.
Figure 1.
CONSORT diagram of patient recruitment.
Table 1.
Characteristics of Patients Receiving Epidural Analgesia During the Day or Night
| Day Group n = 150 |
Night Group n = 150 |
|
|---|---|---|
| Age; y | 28.5 (3.4) | 28.3 (2.7) |
| Weight; kg | 67.2 (7.3) | 66.2 (6.5) |
| Height; cm | 161.1 (4.7) | 160.2 (4.6) |
| Cervical dilatation; cm | 3.3 (0.6) | 3.3 (0.5) |
| Gestational age; wk | 39.1 (1.0) | 39.0 (1.0) |
| Baseline visual analogue scale pain score; cm | 7 [6–7] | 7 [6–8] |
Note: Values are mean (SD) or median [IQR].
Abbreviations: SD, standard deviation; IQR, interquartile range.
The number of patients who had a successful response in each dose subgroup in the two groups is shown in Table 2. From this data, a probit model was fitted with a Pearson goodness-of-fit chi-square p-value of 0.32, indicating that the model fitted the data well. The derived sigmoidal dose-response curves for epidural ropivacaine in the two groups are shown in Figure 2. The estimated values for ED50 were 17.9 (95% CI 15.7 to 20.0) mg in the day group and 22.4 (95% CI 19.9 to 24.8) mg in the night group. The estimated values for ED95 were 32.9 (95% CI 28.9 to 39.0) mg in the day group and 41.3 (95% CI 36.4 to 48.7) mg in the night group. The relative mean potency of ropivacaine in the night group versus the day group was 0.80 (95% CI 0.66 to 0.94). There was no difference in Apgar scores or umbilical arterial pH between groups.
Table 2.
Number of Patients with an Effective Response to Each of the Different Doses of Epidural Ropivacaine During the Day and During the Night. An Effective Response Was Defined as Achievement of a Visual Analogue Scale Pain Score ≤ 3 cm Within 30 minutes After Administration of Epidural Ropivacaine
| Dose (mg) | Day Group n = 25 |
Night Group n = 25 |
|---|---|---|
| 7.5 | 0 | 0 |
| 15 | 8 | 2 |
| 22.5 | 19 | 15 |
| 30 | 23 | 21 |
| 37.5 | 24 | 24 |
| 45 | 25 | 22 |
Note: Data are represented as number.
Figure 2.
Dose-response curves for ropivacaine for initiating epidural analgesia during the day (dashed blue plot) and during the night (solid red plot). Dotted horizontal and vertical lines indicate the positions of ED50 and ED95.
Side effects during the induction period and neonatal outcomes were summarized in Table 3, and no significant differences were found in these parameters. In addition, there were no significant differences in anesthetic outcomes or the rate of induced labor between the two groups.
Table 3.
Side Effects During Induction Period and Neonatal Outcomes
| Day Group | Night Group | P | |
|---|---|---|---|
| Maximum sensory level | T8 (T6, T10) | T8 (T7, T11) | 0.198 |
| Bromage Score (0/1/2/3) | 149/1/0/0 | 150/0/0/0 | >0.99 |
| Maternal bradycardia | 0 (0) | 0 (0) | >0.99 |
| Hypotension | 8 (5.33) | 8 (5.33) | >0.99 |
| Nausea or vomiting | 0 (0) | 0 (0) | >0.99 |
| Pruritus | 0 (0) | 0 (0) | >0.99 |
| Shivering | 1 (0.33) | 0 (0) | >0.99 |
| Fetal bradycardia | 4 (2.66) | 3 (2.00) | 0.702 |
| 1-min Apgar | 10 (10, 10) | 10 (10, 10) | 0.094 |
| 5-min Apgar | 10 (10, 10) | 10 (10, 10) | >0.99 |
| Umbilical arterial pH | 7.24 (7.21–7.32) | 7.25 (7.23–7.27) | 0.375 |
| Induced labor | 49 (32.67) | 42 (28.00) | 0.379 |
Notes: Data shown as number (%), or median (quartiles) as appropriate.
Discussion
In this study, we determined full dose-response curves for ropivacaine for initiating epidural labor analgesia during the day and night. The main finding was that the dose-response curve during the night shifted significantly to the right compared with the day, indicating that when epidural labor analgesia is performed during the night, a greater dose of ropivacaine is required to produce effective analgesia compared with administration during the day. To quantify this difference, we estimated the relative mean potency (difference between ED50 values), which showed a difference of approximately 20% between night and day groups. Of clinical relevance, the differences between ED95 values were approximately the same.
Various factors influence the efficacy of labor analgesia.5 Although several previous studies have reported population-based estimates of dose requirements for local anesthetics for initiating labor analgesia,4,6,7 we believe that for an individual patient, it is important to consider the clinical context and factors related to individual circumstances when selecting doses for initiating epidural labor analgesia. The results of our study suggest that the time of day (night vs day) is one of the factors that should be included in such considerations.
Previous studies have investigated the chronobiology of epidural labor analgesia. Earlier studies reported that the duration of epidural and intrathecal drugs administered for labor analgesia was shorter during the night than during the day8–10 although this finding has not been consistent in all studies.11 In our previous study,3 rather than focusing on the duration of analgesia, we quantified the effect of the time of day by comparing epidural dose requirements. Similar to the results of the current study, we found that the dose requirement for epidural ropivacaine increased at night. However, in that study, we used an up-and-down methodology that only enabled estimation of the median effective dose. In the current study, we extended this work by determining full dose-response curves, which demonstrated that dose requirement was also increased at night at points higher than the dose-response curve, including ED95. This is important because we believe that in typical clinical practice, it is likely that most anesthetists normally choose to administer doses closer to ED95 than ED50.
Although the exact mechanism underlying the increased local anesthetic requirement for epidural labor analgesia at night is unknown, several factors may contribute to this. First, the neuroendocrine system exhibits circadian rhythms, including diurnal fluctuations in plasma concentrations of cortisol, adrenocorticotropic hormone, 5-hydroxytryptamine, endorphins, and oxytocin.12,13 Elevated nocturnal levels of oxytocin and reduced nocturnal levels of beta-endorphin may lead to decreased pain tolerance in parturients and heightened pain sensitivity during late pregnancy.13 Second, sleep disruption exacerbates pain sensitivity and induces nociceptive hypersensitivity,14 and the onset of labor in pregnant women is accompanied by sleep deprivation and heightened fatigue, which negatively impacts the functioning of the opioid and 5-hydroxytryptamine systems, thereby exacerbating labor pain.15,16 The experience of pain intensifies arousal, whereas sleep deprivation amplifies sensitivity to pain, resulting in a detrimental cycle that exacerbates both factors.17 Third, variations in external environmental conditions between day and night may also contribute to the divergent pain perception experienced by patients.18 For instance, during nocturnal hours, when the ambient environment is characterized by reduced noise levels, patients may allocate greater attention to monitoring contractions.
Our study had some limitations. First, the allocation of patients to the two groups was determined by the time of day, which was not randomized. However, patient recruitment for both groups was conducted during the same study period, and the allocation of doses within each group was randomized—neither the participants nor the anesthesiologists were aware of the ropivacaine dosage administered to each group—thereby substantially reducing potential bias and enhancing internal validity. Second, the investigation was designed to investigate the dose-response relationship solely for ropivacaine. In clinical practice, it is common for clinicians to add lipophilic opioids, such as fentanyl or sufentanil, to the local anesthetic. Given that this study investigated primiparas with singleton only, the generizability of the results derived from this study was limited due to that multiparas may experience more tense labor pain. Finally, it remains to be determined whether the time of day has the same quantitative effect on the dose requirement of local anesthetic–opioid mixtures.
Conclusions
In summary, we have demonstrated a right shift in the dose-response curve for ropivacaine used to initiate epidural labor analgesia during the night compared to during the day. The dose requirement for ropivacaine was approximately 20% higher at night than during the day. These results suggest that the time of day is an important factor that should be considered when selecting local anesthetic doses for initiating epidural labor analgesia.
Funding Statement
There is no funding to report.
Abbreviation
ED95, 95% effective dose.
Data Sharing Statement
Data related to this study can be obtained by contacting the corresponding author if reasonable.
Ethics Approval and Consent to Participate
The Ethical Committee of Hangzhou Women’s Hospital approved this study and provided the certificate (no. 201901-1). All patients involved in this study were informed and all of them signed a written informed consent.
Disclosure
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- 1.Aya AG, Vialles N, Mangin R, et al. Chronobiology of labour pain perception: an observational study. Br J Anaesth. 2004;93:451–8. doi: 10.1093/bja/aeh223 [DOI] [PubMed] [Google Scholar]
- 2.Desai S, Leong SB, Yvonne L, Sia A. Chronobiology of parturients receiving neuraxial labour analgesia with ropivacaine and fentanyl: a prospective cohort study. Int J Obstet Anesth. 2009;18:43–47. doi: 10.1016/j.ijoa.2008.07.012 [DOI] [PubMed] [Google Scholar]
- 3.Deng J, Wei C, Liu L, Qian J, Xiao F, Chen X. Circadian variation in the median effective dose of epidural ropivacaine for labor analgesia. Front Med. 2021;8:669264. doi: 10.3389/fmed.2021.669264 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ngan Kee WD, Ng FF, Khaw KS, Lee A, Gin T. Determination and comparison of graded dose-response curves for epidural bupivacaine and ropivacaine for analgesia in laboring nulliparous women. Anesthesiology. 2010;113:445–453. doi: 10.1097/ALN.0b013e3181bdf9da [DOI] [PubMed] [Google Scholar]
- 5.Bonnet MP, Prunet C, Baillard C, Kpéa L, Blondel B, Le Ray C. Anesthetic and obstetrical factors associated with the effectiveness of epidural analgesia for labor pain relief: an observational population-based study. Reg Anesth Pain Med. 2017;42:109–116. doi: 10.1097/AAP.0000000000000517 [DOI] [PubMed] [Google Scholar]
- 6.Lee BB, Ngan Kee WD, Wong EL, Liu JY. Dose-response study of epidural ropivacaine for labor analgesia. Anesthesiology. 2001;94:767–772. doi: 10.1097/00000542-200105000-00013 [DOI] [PubMed] [Google Scholar]
- 7.Polley LS, Columb MO, Naughton NN, Wagner DS, van de Ven CJ, Goralski KH. Relative analgesic potencies of levobupivacaine and ropivacaine for epidural analgesia in labor. Anesthesiology. 2003;99:1354–1358. doi: 10.1097/00000542-200312000-00017 [DOI] [PubMed] [Google Scholar]
- 8.Debon R, Chassard D, Duflo F, Boselli E, Bryssine B, Allaouchiche B. Chronobiology of epidural ropivacaine: variations in the duration of action related to the hour of administration. Anesthesiology. 2002;96:542–545. doi: 10.1097/00000542-200203000-00006 [DOI] [PubMed] [Google Scholar]
- 9.Debon R, Boselli E, Guyot R, Allaouchiche B, Lemmer B, Chassard D. Chronopharmacology of intrathecal sufentanil for labor analgesia: daily variations in duration of action. Anesthesiology. 2004;101:978–982. doi: 10.1097/00000542-200410000-00024 [DOI] [PubMed] [Google Scholar]
- 10.Pan PH, Lee S, Harris L. Chronobiology of subarachnoid fentanyl for labor analgesia. Anesthesiology. 2005;103:595–599. doi: 10.1097/00000542-200509000-00023 [DOI] [PubMed] [Google Scholar]
- 11.Scavone BM, McCarthy RJ, Wong CA, Sullivan JT. The influence of time of day of administration on duration of opioid labor analgesia. Anesthesia Analg. 2010;111:986–991. doi: 10.1213/ANE.0b013e3181c29390 [DOI] [PubMed] [Google Scholar]
- 12.Allolio B, Hoffmann J, Linton EA, Winkelmann W, Kusche M, Schulte HM. Diurnal salivary cortisol patterns during pregnancy and after delivery: relationship to plasma corticotrophin-releasing-hormone. Clin Endocrinol. 1990;33:279–289. doi: 10.1111/j.1365-2265.1990.tb00492.x [DOI] [PubMed] [Google Scholar]
- 13.Lindow SW, Newham A, Hendricks MS, Thompson JW, van der Spuy ZM. The 24-hour rhythm of oxytocin and beta-endorphin secretion in human pregnancy. Clin Endocrinol. 1996;45:443–446. doi: 10.1046/j.1365-2265.1996.8290840.x [DOI] [PubMed] [Google Scholar]
- 14.Schrimpf M, Liegl G, Boeckle M, Leitner A, Geisler P, Pieh C. The effect of sleep deprivation on pain perception in healthy subjects: a meta-analysis. Sleep Med. 2015;16:1313–1320. doi: 10.1016/j.sleep.2015.07.022 [DOI] [PubMed] [Google Scholar]
- 15.Larson AA. Desensitization to intrathecal substance P in mice: possible involvement of opioids. Pain. 1988;32:367–374. doi: 10.1016/0304-3959(88)90049-8 [DOI] [PubMed] [Google Scholar]
- 16.Jasmin L, Tien D, Weinshenker D, et al. The NK1 receptor mediates both the hyperalgesia and the resistance to morphine in mice lacking noradrenaline. Proc Natl Acad Sci U S A. 2002;99:1029–1034. doi: 10.1073/pnas.012598599 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Lautenbacher S, Kundermann B, Krieg JC. Sleep deprivation and pain perception. Sleep Med Rev. 2006;10:357–369. doi: 10.1016/j.smrv.2005.08.001 [DOI] [PubMed] [Google Scholar]
- 18.Shafer SL, Lemmer B, Boselli E, et al. Pitfalls in chronobiology: a suggested analysis using intrathecal bupivacaine analgesia as an example. Anesthesia Analg. 2010;111:980–985. doi: 10.1213/ANE.0b013e3181dd22d4 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Data related to this study can be obtained by contacting the corresponding author if reasonable.


