Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2026 Feb 17;16:9387. doi: 10.1038/s41598-026-40047-y

MyoFuse is a fully AI-based workflow for automated quantification of skeletal muscle cell fusion in vitro

Benjamin Lair 1,6,✉, Clément Cazorla 2,3, Alicia Lobeto 1, Axel Labour 1, Lorenzo Couloutchy 1, Claire Laurens 1, Arild C Rustan 4, Thomas Chaillou 1, Pierre Weiss 3,5, Remy Flores-Flores 1, Cedric Moro 1,6,✉
PMCID: PMC13003016  PMID: 41703189

Abstract

The fusion index (FI) is widely used to assess myoblast differentiation into myotubes, but manual quantification is tedious and biased. Existing automated methods face limitations in nucleus segmentation and classification and often misidentify myoblast nuclei located above or below myotubes, leading to FI overestimation. To address these issues, we developed MyoFuse, an AI-based workflow enabling fully automated and unbiased FI quantification. MyoFuse combines nucleus segmentation using Cellpose with a classification network trained with Svetlana on fluorescence images of mouse C2C12 and human primary myotubes. Performance was evaluated by comparing MyoFuse-derived FI values with expert annotations and by assessing classification accuracy at the single-nucleus level. MyoFuse achieved strong accuracy scores in mouse C2C12 and human primary myotubes (0.954 and 0.911 respectively), and showed strong correlations with expert-derived FI values (r = 0.991 and r = 0.937 respectively; p < 0.0001). Unlike current approaches that overestimate FI, MyoFuse reliably segments nuclei even within dense clusters and distinguishes myotube from myoblast nuclei based solely on cytoplasmic staining. By processing large images, it further reduces selection bias and accounts for heterogeneity in myotube density. MyoFuse thus provides a robust, high-throughput, and accurate method for FI quantification in skeletal muscle cell culture.

Supplementary Information

The online version contains supplementary material available at 10.1038/s41598-026-40047-y.

Keywords: Skeletal muscle, Myogenesis, Fusion index, Artificial intelligence, Neural network

Subject terms: Biological techniques, Computational biology and bioinformatics

Introduction

Culture of skeletal muscle cells typically involves proliferation of myoblasts and subsequent induction of differentiation through serum deprivation1. Differentiation of myoblasts into polynucleated myotubes requires myoblast fusion2. Therefore, investigating the myogenic development of skeletal muscle cells often implies the determination of the fusion index (FI), which is defined as the number of nuclei within myotubes over the total nuclei count3. Assessment of the FI in response to various biological conditions is often performed by simultaneous immunofluorescent staining of nucleus-specific and myotube-specific proteins such as myosin heavy chain (MyHC)4or desmin5. The number of nuclei within myotubes is then deduced from the superimposition of nucleus-specific and myotube-specific. Sometimes, additional Myogenin staining is performed to confirm that nuclei are indeed located in the myotube rather than inside an underlying myoblast5,6. This approach will be called the “mask method” throughout the paper and most manual and automated workflows have relied on this strategy to quantify the FI until now.

The manual determination of the FI is time consuming since it requires processing a high number of nuclei per biological replicate to obtain representative results. Moreover, quantifying the FI can be biased depending on the area chosen in the culture wells. Automated tools rely on the same logic that governs manual analysis, with the benefit of saving time and improving robustness in the results. One of the first published plugin for automated FI measurement was ViaFuse4. This tool introduced a new strategy to bypass the issue of clustered myonuclei that was lacking in previous methods7–9. Nuclei tend to aggregate in myotubes, thus complicating the counting, even for expert eyes. ViaFuse was therefore built to determine the median area of isolated nuclei and use this value to compute the number of nuclei in clusters. This leads to an indirect estimation of the number of nuclei in each cluster. Nuclei labels are then classified based on the superimposition with a myotube mask, built with a fluorescence signal thresholding. This classification step can be compromised by issues affecting the precision of the myotube mask, such as staining heterogeneity, threshold selection but also filling of the holes created by the nuclei within the myotube signal. More recently, a Myotube Analyzer software was developed, able to determine the FI, among other characteristics. This plugin also utilizes an adjusted mask method and the nuclei segmentation step is informed by an average nucleus size10. Lately, “SEPO-FI”, a new solution based on pattern recognition for nuclei detection and deep learning for classification was proposed11. However, all methods currently available rely on nuclei detection strategies that fail to properly isolate single nuclei in clusters. Also, they are built on the hypothesis that relative localization between nucleus-specific and myotube-specific signals enables reliable classification of myonuclei.

To further improve the accuracy and throughput of automated FI calculation, we took advantage of the recent development of neural networks solutions for image analysis. We show that myoblast nuclei can often be located above or below myotubes, impeding accurate and reliable quantification of the FI when the nuclei classification is performed with myotube masking. Instead, we observe that the presence of a nucleus in the myotube cytoplasm correlates with a local loss of MyHC fluorescence. We propose a new workflow that employs direct segmentation of nuclei by retraining a Cellpose 2.0 model for this specific task12,13. We performed subsequent classification of nuclei with a lightweight convolutional neural network trained with the Svetlana Napari plugin14. This classifier was trained with images of both mouse C2C12 and human primary myotubes and further validated on these two cell types. Altogether, this workflow represents a new step towards reliable, fast and high throughput analysis of cultured skeletal muscle cell images.

Methods

Ethics declaration

Human skeletal muscle cell cultures were established from the rectus abdominis muscle of young healthy subjects and the vastus lateralis muscle of obese younger and older subjects as previously described15–17. Each clinical protocol was approved by an institutional review board, and all volunteers gave written informed consent. Ethical approval was obtained from the National Committee for Research Ethics (Oslo, Norway) and the Comité de Protection des Personnes Sud-Ouest et Outre-mer II (protocol no. 13–149-03, NCT02161926). The studies were in agreement with the Declaration of Helsinki, and the French National Institute of Health and Medical Research (INSERM) and the Toulouse University Hospital ethics regulation.

Cell culture

The C2C12 mouse myoblast cell line was obtained from the American Type Culture Collection (CRL-1772TM, ATCC, Manassas, VA). C2C12 cells were grown in 24-well plates until 80–90% confluence in medium composed of high-glucose Dulbecco’s modified eagle medium (DMEM) (D6429, Sigma), 10% fetal bovine serum (FBS) (10270-016, Gibco, Thermo Scientific), 100 U/mL penicillin and 100 µg/mL streptomycin (15140-122, Gibco, Thermo Scientific). Cells were maintained at 37 °C with 5% CO2. Differentiation was initiated by replacing FBS with 2% horse serum (16051030, Gibco, Thermo Scientific). Satellite cells from the rectus abdominis and vastus lateralis muscle were cultured in 24-well or 12-well plates as previously described6,18,19. Alternatively, for confocal microscopy imaging, mouse C2C12 and human primary muscle cells were cultured in glass bottom dishes (Cellview™ Cell Culture Dish, 627860, Greiner Bio-One). After four days of differentiation, cells were fixed in 2% formaldehyde for 10 min followed by 20 min in 4% formaldehyde and kept in Dulbecco’s phosphate buffered saline (DPBS) at 4 °C until processing.

Immunocytochemistry and microscopy

Cells were permeabilized in 0.4% Triton X-100 (T9284, Sigma) solution for 20 min at room temperature. Epitope unmasking was performed in 0.4% glycine (G8790, Sigma) for 15 min. Cells were blocked in 3% Bovine serum albumin (BSA) (A7030, Sigma) for 30 min. They were then incubated overnight at 4 °C with primary MF-20 antibody (DSHB, 1:64) in an immunostaining buffer containing 0.2% Triton X-100, 0.05% Tween-20 (P1379, Sigma) and 0.1% BSA. The next day, cells were washed twice with immunostaining buffer for 20 min before being incubated with anti-mouse goat Alexa Fluor 514 antibody (A31555, Invitrogen, Thermo Scientific, 1:250) for 90 min at 20 °C. Cells were then washed in DPBS and nuclei were labeled with 10 µg/mL Hoechst 33,342 (H3570, Thermo Scientific) for 5 min. Using a wide-field fluorescence microscope Zeiss Cell Observer, central zones corresponding to 50% or 25% of the well surface, when using 24-well or 12-well plates respectively, were acquired with a 10X/0.3 Plan-NeoFluar objective, LED illumination Zeiss Colibri7 and a Hamamatsu ORCA-R2 Camera. Mosaics were then stitched and individual well images were saved using Zen Blue software (Carl Zeiss). For training and validation of the models, four individual images from each cell type were used to randomly generate 80 images (1000 × 1000 pixels). Alternatively, mouse C2C12 and human primary muscle cells cultured in glass bottom dishes were imaged using a Zeiss LSM780 or Zeiss LSM900 line scanning confocal microscope with a 63X/1.4 Plan-Apochromat oil immersion objective and a sampling rate of 0.198 μm in XY and 0.190–0.240 μm in Z. Orthogonal representations were obtained using the Zen Blue software (Carl Zeiss). The corresponding zones were also imaged with a fluorescence widefield microscope Zeiss Cell observer, a 10X/0.3 Plan-NeoFluar objective, LED illumination Zeiss Colibri7 and a Hamamatsu ORCA-R2 Camera.

Training the segmentation model

A Cellpose model for nuclei segmentation was trained using Cellpose 2.0 human-in-the-loop pipeline13. The model was trained on 5 images (1024 × 1024 pixels, total of 2518 nuclei) by transfer learning from the Cellpose generic model “nuclei” (learning rate 0.1, weight decay 0.0001, epochs number 100).

Training the classification model

The MyoFuse classifier was trained with the Svetlana plugin for Napari14. Four independent parent images for C2C12 mouse and human primary cells were split into non-redundant patches. For each cell type, 10 images (1000 × 1000 pixels) were randomly assigned to the training set, as described in Table S1. Their corresponding label masks were annotated using the annotation plugin. Annotation was done based on the MyHC fluorescence channel only, using a 200-pixel patch size. Nuclei associated with a decrease in MyHC signal were considered in a myotube. After “max to one” normalization of the training images, a compact 2D convolutional neural network composed of four convolutional blocks (Conv–ReLU–BatchNorm–MaxPool), each containing 16 filters with a 5 × 5 kernel size (21 026 trainable parameters in total), was trained for 140 epochs using a learning rate of 10⁻³ and a step decay of 0.975. Class weights were applied to the loss function in order to counterbalance the potential imbalance between classes. The dataset was augmented using random rotations and flips.

Manual quantification of nuclei and FI

Manual annotation for validation of the workflow was done using 15 images (1000 × 1000 pixels) for each cell type. Nuclei were manually annotated using the Cell Counter plugin in ImageJ following the same annotation criteria as those applied to the training images. The total nuclei number and FI were then evaluated using Eq. (1):

graphic file with name d33e453.gif 1

To analyze precision of the classifier, each individual segmented nucleus class was compared. Classification accuracy for both cell types was calculated with Eq. (2):

graphic file with name d33e462.gif 2

Precision, recall, and F1-score (standard binary definitions) were reported in the supplementary tables. ROC curves and associated area under curve (AUC) values were computed from continuous predicted probabilities using scikit-learn. Because the classifier outputs a single probability for the myonuclei class (with the other class having probability 1 – p), ROC and AUC are shown only for the myonuclei class.

Mask method for FI and myotube surface quantification

To compare the FI obtained with our automated AI based workflow and the commonly used myotube mask method, 80 images (1000 × 1000 pixels) were processed using a custom script for ImageJ. The background was extracted from the MyHC channel image and a myotube mask was created using a fluorescence threshold. The myotube mask and the nuclei label mask, obtained with the segmentation model, were processed using a custom Python script. Nuclei were considered in a myotube if at least 90% of the nuclei label surface was included in the myotube mask. Myotube surface as a percentage of the image surface and FI were then evaluated with Eq. (1). Additionally, FI values with varying mask thresholds (60–98%) were computed and used to assess the impact of threshold selection on correlation and relative error between FI values derived from mask method and manual annotations.

The importance of selection bias

In order to demonstrate the risk of bias in FI quantification, a large image acquired via wide field microscopy was analyzed. The image was partitioned into tiles (1168 × 1005 pixels) and the FI was computed using the workflow and compared to the FI determined by the workflow for the complete image. The FI normalized difference was defined for each tile as follows:

graphic file with name d33e481.gif 3

To simulate the random selection of several zones by the experimenter, we evaluated the standard deviations and 95% confidence intervals obtained for a generation of 1000 random combinations of n tiles, where n varied from 1 to 120. The mean FI was evaluated for each value of n and set at 100%.

Statistical analyses

All statistical analyses were performed using GraphPad Prism 10.1.2 for Windows (GraphPad Software Inc., San Diego, CA). Normal distribution and homogeneity of variance of the data were tested using Shapiro-Wilk and F tests, respectively. Pearson correlation and linear regression analyses were performed to compare manual quantification or mask method versus MyoFuse. Bland-Altman plots were used to show method agreement and bias. Performance of the automated predictions versus manual annotations were assessed with confusion matrices and derived metrics were reported in supplementary tables. Statistical significance was set at p < 0.05.

Results

Misleading localization of myoblast nuclei

As stated earlier, traditional manual methods for FI determination and more recent automated solutions rely on the nuclei classification by thresholding of the myotube-specific immunofluorescent signal. If a nucleus appears be located inside a myotube in the 2D microscopy image, it will be considered as a myonucleus. However, we here propose that this criterion is not sufficient as nuclei that seem to be located inside a myotube (Fig. 1A) can in fact belong to a myoblast located below (Fig. 1B) or above (Fig. 1C) as observed here in C2C12 myotubes. The same observations, though less frequent due to lower cell density, were made in human primary myotubes originating from rectus abdominis muscle samples (Fig. 1D-E). This observation is not new and has led several groups to use concomitant myogenin staining to distinguish “true” myonuclei from nuclei belonging to nearby myoblasts5,6. To the best of our knowledge, this method has only been applied to manual FI determination and requires additional staining, adding a layer of complexity for automated, large-scale analysis.

Fig. 1.

Fig. 1

Superposition of nucleus-specific and myotube-specific can be misleading for myonuclei identification. Images of mouse C2C12 (A) and human primary myotubes derived from rectus abdominis (D) with MyHC and Hoechst staining (Wide-field microscope – 10x). Corresponding zones with orthogonal representations in mouse C2C12 (B, C) and human primary (E) myotubes (Confocal microscope − 64x).

One characteristic that we sought to exploit in our analysis workflow is that myonuclei, due to the relative space that they occupy in the myotube cytoplasm, systematically lead to a loss of signal intensity in the MyHC fluorescence channel. Indeed, we observed that myonuclei form dark spots in the myotube image that distinguish them from myoblast nuclei located above or below (Fig. 1A and D).

A new workflow based on neural networks to segment and classify nuclei with high throughput

A first barrier to automated FI calculation is the ability to isolate myonuclei. Myotube development often leads to the formation of myonuclei clusters that are difficult to segment with traditional tools. We trained a model to segment densely packed Hoescht-stained nuclei with the Cellpose 2.0 human-in-the-loop pipeline12,13and obtain a mask of nuclei labels for subsequent classification. The second part of the workflow involves classification of the nuclei based on the MyHC immunofluorescence signal. Specifically, a classifier was trained using the Svetlana plugin for Napari14. Classification requires only the MyHC channel. In the training data set, nuclei were considered inside myotubes when the nuclei label was located in a myotube and was accompanied by a decrease of MyHC signal (a “hole”). The trained model allows for fast classification of a high number of nucleus labels. An image containing approximately 150 000 nuclei can be classified in less than 3 minutes (128Go RAM; CPU: Intel Xeon w7-3445 2.59 GHz; GPU: Nvidia RTX A4500). The workflow is summarized in Fig. 2.

Fig. 2.

Fig. 2

Description of the MyoFuse workflow. The workflow requires myotube specific immunofluorescent staining (MyHC in this case) and nuclei staining (Hoechst here). Nuclei are first segmented thanks to a Cellpose model. Mask of nuclei labels is subsequently used together with normalized myotube specific-staining channel for nuclei classification using a second neural network. The difference with the masking method is illustrated.

Validation of the workflow involved quantitative comparison of nuclei detection and FI calculation compared to manual annotation. Validation was performed in mouse C2C12 myotubes and human primary myotubes derived from the rectus abdominis muscle. Automated nuclei segmentation accuracy was very high in both cell types, when compared to manual annotations, with Pearson correlation coefficient r > 0.99 (Fig. 3A-B). Next, we determined the accuracy of the FI evaluation, as the result of both segmentation and classification steps. The workflow provided FI values highly similar to manual annotation for mouse C2C12 myotubes (r = 0.991, p < 0,0001, Fig. 3C). A high accuracy was also obtained in human myotubes (r = 0.937, p < 0,0001, Fig. 3D), demonstrating the validity of this new workflow in both cell types. Bland-Altman plots further highlight the absence of proportional bias in both cell types compared to manual annotation (Fig. 3E -F). To better analyze the performance of the classifier in both cell types, each label prediction was compared to manual annotation. Confusion matrixes are presented in Fig. 4. Accuracy score reached 0.954 in C2C12 myotubes (Fig. 4A) and 0.911 in human primary myotubes (Fig. 4B). ROC curve AUC values were 0.988 in C2C12 myotubes (Fig. 4C) and 0.975 in human primary myotubes (Fig. 4D) supporting the high discriminative performance of the neural network. Validation statistics are presented in Table S2 and Table S3 for mouse C2C12 and primary human myotubes derived from rectus abdominis respectively.

Fig. 3.

Fig. 3

Validation of MyoFuse against manual quantification. Total number of detected nuclei by the workflow compared to manual quantification in mouse C2C12 (A) and human primary myotubes from the rectus abdominis muscle (B). Comparison between FI computed by the workflow compared to manual analysis in mouse C2C12 (C) and human primary (D) myotubes (n = 15 images per cell types). Bland-Altman plots comparing FI obtained with MyoFuse to values obtained with manual annotations for mouse C2C12 (E) and human primary (F) myotubes. Dashed lines represent mean bias value ± 1.96 SD. Linear regression slopes with 95% CI and p values are reported for both cell types.

Fig. 4.

Fig. 4

Confusion matrixes and ROC curves assessing the accuracy of MyoFuse classification versus manual annotations. Automated predictions of nuclei classification with MyoFuse were compared with manual annotations. Confusion matrixes are reported for C2C12 mouse myotubes (A) and human primary myotubes (B). ROC curves and associated AUC are presented for C2C12 mouse myotubes (C) and human primary myotubes (D).

To rule out the possibility that any form of data leakage could have inflated the performance of MyoFuse, we further validated the classifier against manual annotation in human primary myotubes derived from the vastus lateralis muscle, which exhibit morphological differences with myotubes derived from the rectus abdominis muscle. No images of this cell type were included in the training set and both immunofluorescence staining and imaging were performed during independent experiments. Confusion matrix (Fig. 5A) and ROC curve (Fig. 5B) indicate strong classification performance with an accuracy of 0.944. and a ROC curve AUC of 0.975. All validation statistics are presented in Table S4.

Fig. 5.

Fig. 5

External validation of MyoFuse against manual quantification in human myotubes derived from the Vastus lateralis muscle. Automated predictions of nuclei classification with MyoFuse were compared with manual annotations. Confusion matrix (A) and ROC curve with associated AUC (B) are presented for human primary myotubes.

Biased estimation of myotube FI when using the mask method

We further investigated the impact of this new approach on the FI values. To do so we first compared the FI obtained with the workflow to the automated myotube mask strategy. To achieve this, we combined Cellpose 2.0 nuclei segmentation with subsequent classification using our own mask method as described in the method section. The comparison of the two automated methods allowed us to process a high number of images, covering a wide range of FI values. Bland-Altman representations show a bias towards overestimation of FI in both cell types with the mask method (Fig. 6A-B). We next analyzed the relationship between the myotube surface and the FI depending on the quantification method employed. Myotube surface was determined by using the relative surface occupied by the myotube mask. In both cell types and with both methods, myotube surface and fusion appeared positively correlated (Fig. 6C-D). Also, the slope of this correlation was steeper with the mask method. Of note, the relationship between myotube surface and mask method derived FI was close to a linear function in C2C12 myotubes (Fig. 6C). These results highlight the fact that the mask method leads to an overestimation of the FI. This bias is amplified when myotubes are larger and cover a greater proportion of the culture surface, as they tend to cover or be covered by surrounding myoblasts. In order to evaluate the possible effect of threshold selection on FI accuracy with the mask method, we computed linear regression and mean relative error of FI values from the mask method compared to manual annotations with increasing threshold values (60–98%). Results in both cell types show that correlation and FI errors decrease as threshold increases (Fig. S1A–D). However, this apparent improvement does not necessarily indicate higher accuracy. With stricter thresholds, small inaccuracies in myotube mask boundaries can cause myonuclei located near the myotube periphery to be excluded, leading to an increase in false negatives. As a result, FI values may appear closer to manual annotations because missed myonuclei offset nuclei that were incorrectly included, rather than because the mask method truly improves. Bland–Altman plots comparing FI values from the mask method (90% threshold, red dot) and manual annotations in both cell types further indicate an overestimation bias of the mask method (Fig. S1E–F).

Fig. 6.

Fig. 6

Assessment of the concordance of MyoFuse with the myotube masking method. Bland-Altman plots comparing FI obtained with MyoFuse to values obtained with the myotube mask classification method for mouse C2C12 (A) and human primary (B) myotubes. Ratio between the two methods is plotted against the average value. Dashed lines represent mean bias value ± 1.96 SD. Relation between myotube surface obtained using a fluorescence thresholding and FI with both methods, in mouse C2C12 (C) and human primary (D) myotubes (n = 80 images per cell types).

MyoFuse classifier allows for accurate and high-throughput analysis of myotubes FI

One of the main goals behind automated image analysis is to improve analysis throughput while limiting experimenter bias and errors, which can be amplified when performing long and tedious tasks such as nuclei classification. To constrain selection bias and guarantee that obtained FI are as close as possible to the biological truth, we propose to combine automated microscopy with our neural-network workflow analysis. Indeed, microscopes equipped with a motorized stage are common and allow for large field imaging corresponding to the central part of a 24-well plate well (50% of the well surface) (Fig. 7A). We performed FI computing using our workflow on the whole image and then extracted the FI of each tile composing the image. The heatmap clearly highlights the variability of the FI observed in the well (Fig. 7B). The magnitude of the variability is even more obvious when looking at the normalized difference in each tile compared to the average FI value (Fig. 7C). In this line, the last graph represents the evolution of standard deviation and 95% CI of the normalized FI when randomly selecting an increasing number of tiles in the image (Fig. 7D). As each tile contains several hundred of myonuclei, this highlights the need to classify a very large number of nuclei in distinct regions of the image to obtain accurate and reproducible results. Selection bias could still occur and lead to erroneous values in certain samples. A combined use of automated microscopy and AI-based analysis enables to overcome these issues and to increase the number of biological samples and technical replicates.

Fig. 7.

Fig. 7

Accurate FI quantification requires a very high number of nuclei. Large mouse C2C12 myotube image (MyHC staining) used for subsequent analyses (A). This corresponds to the central part of a 24-well plate well (50% of the well surface). Heatmap of the FI values obtained for each individual tiles composing the image (B). Heatmap of the relative difference of FI measured in each individual tiles compared to the mean values of the image (C). Evolution of the normalized FI standard deviation and 95% CI when randomly selecting a growing number of tiles in the well for FI quantification (D). The number of images required to achieve a 95% CI with FI relative error within ± 5% is reported as a red vertical dashed line.

Discussion

Manual quantification of the FI is tedious and can lead to significant biases. Several programs partly based on AI have recently been developed to improve accuracy and enable high throughput analyses4,9–11. Yet, these methods still rely on the myotube mask classification or deep learning strategies that follow the same classification logic. The last published software, SEPO-FI, does not allow to isolate every nucleus and instead tends to detect clusters when nuclei density is too high. Though it provides an accurate quantification of nuclei in those clusters, every nucleus is then classified in the same category, which can lead to numerous errors11. The classifier has also been trained with an underlying logic that corresponds to the masking method, meaning that nuclei are considered in myotubes when nuclei and myotube signals are superimposed. However, we here demonstrate that the masking method for nuclei classification can lead to a significant overestimation of the FI. Indeed, this method classifies nuclei above or below myotube as being inside. The first step of our workflow overcomes the limitations of previous methods relative to nuclei detection through direct segmentation of nuclei using a Cellpose model specifically trained for this purpose. In this line, a similar approach was recently proposed20, using Mesmer for accurate nuclei segmentation21. In both C2C12 and human myotubes, the proposed Cellpose-based solution proved to be extremely accurate. In the second step of our workflow, the nuclei label mask is then processed directly together with the MyHC fluorescence image to classify nuclei using a classification neural network. The training dataset was generated based on the presence of a local loss in the myotube specific signal. Therefore, the workflow can classify nuclei located above or below myotubes as outside myotubes. Moreover, it does not require pre-processing of images or determination of a fluorescence intensity threshold and is less dependent on myotube fluorescence homogeneity. When tested against manual quantification based on the same classification principle, we demonstrate the high accuracy of MyoFuse in mouse and human myotubes. In addition, MyoFuse was able to accurately classify nuclei from human primary myotube derived from the vastus lateralis muscle, which was not included in the training set. Therefore, we here provide a new and more reliable strategy to quickly compute FI.

We also consider that this workflow is a new step towards high-throughput and unbiased analysis of FI. In combination with moderate magnification automated microscopy, it allows the processing of very large images, accounting for heterogeneity often observed in skeletal cell culture wells. Both segmentation and classification steps can be performed in batch, separately or together. The method can therefore remove selection bias that can occur at the imaging and analysis steps when the latter is done either manually or automatically using smaller zones or fluorescence intensity thresholds that can vary from one experiment to another. As of today, MyoFuse is available as a single python notebook that can be downloaded along with the necessary model files and executed with “Voila” to generate a user-friendly graphical interface.

Nevertheless, several limitations must be acknowledged. Processing of very large images can cause memory issues depending on computer specifications. In this case, prior subdivision of the images will be necessary. Though we clearly show that a nucleus contained in the myotube cytoplasm leads to a loss of fluorescence intensity in the MyHC fluorescence channels, it is possible that superimposition of several myotubes alters the ability of the classifier to make accurate prediction, as these situations are even difficult to resolve for expert scientists. FI is often calculated based on myotubes containing at least two myonuclei. We were unfortunately not able to train the classifier to distinguish nuclei belonging to mononucleated, MyHC-positive muscle cells, from those belonging to polynucleated myotubes. Though this situation is not the most prevalent, depending on cell confluence, future developments will be required to achieve this degree of precision. It is also not possible to manually correct the result of classification. However, this tool was designed to purposely manipulate large images containing several thousands of nuclei and eliminate the need for manual intervention. Lastly, though the classifier was trained on a high number of nuclei in two different cell types and meticulously validated, its performance may suffer in certain circumstances. The use of a different cell type, myotube staining (protein target, fluorophore) or a different microscope with varying magnification and resolution could impair the accuracy of the trained model. In those cases, performance could be improved by retraining the classifier by using the Svetlana training interface14. Future training of the model will consolidate its accuracy and versatility.

In summary, we present MyoFuse as a novel workflow enabling accurate segmentation and classification of nuclei in skeletal muscle cells in vitro. Unlike previous methods, it is fully based on neural networks, requiring neither image pre-processing nor fluorescence intensity thresholding. Moreover, it is specifically trained to discriminate true myonuclei from surrounding myoblast nuclei located above or below the myotubes. Altogether, this AI-based workflow offers a high-throughput, unbiased solution for quantifying the myogenic FI, thereby enhancing data reliability and reproducibility.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary Material 1 (808.4KB, pdf)

Acknowledgements

We are grateful to the personnel of the Genotoul TRI histology and imaging facility core for excellent technical support.

Abbreviations

AI

Artificial intelligence

BMI

Body mass index

BSA

Bovine serum albumin

DMEM

Dulbecco’s modified eagle medium

DPBS

Dulbecco’s phosphate buffered saline

FI

Fusion Index

MyHC

Myosin heavy chain

Author contributions

Conceptualization: BL and RF. Methodology, investigation, software: BL, RF, Al.L, CC, Ax.L, LC, TC and PW. Validation: BL, Al.L and RF. Resources: ACR and CM. Writing – original draft: BL, RF and CM. Writing – review and editing: all authors. Supervision: BL, RF, and CM. Funding: BL, CM.

Funding

This work was supported by grants from Inserm, Société Francophone du Diabète, European Foundation for the Study of Diabetes EFSD/Boehringer Ingelheim European Research Programme on “Multi-System Challenges in Diabetes”, Agence Nationale de la Recherche (ANR-21-CE14-0057-01), and Fondation pour la Recherche Médicale (EQU202303016316) (C.M.). B.L. was supported by a Ph.D. fellowship from Fondation pour la Recherche Médicale (FDT202204014748).

Data availability

The MyoFuse application with codes, model files, tutorials and test images can be found on the project home page: [https://github.com/BenLair/MyoFuse](https:/github.com/BenLair/MyoFuse). It is distributed under MIT License without any restrictions to use by non-academics.Images used to train the classifier and labels generated with the Svetlana plugin are available at: [https://zenodo.org/records/14731491](https:/zenodo.org/records/14731491). Other images, datasets and codes used in the current study are available from the corresponding authors upon reasonable request.

Declarations

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Benjamin Lair, Email: benjamin.lair@inserm.fr.

Cedric Moro, Email: cedric.moro@inserm.fr.

References

  • 1.Delaporte, C., Dautreaux, B. & Fardeau, M. Human myotube differentiation in vitro in different culture conditions. Biol. Cell.57, 17–22 (1986). [DOI] [PubMed] [Google Scholar]
  • 2.Lehka, L. & Rędowicz, M. J. Mechanisms regulating myoblast fusion: A multilevel interplay. Semin Cell. Dev. Biol.104, 81–92 (2020). [DOI] [PubMed] [Google Scholar]
  • 3.Meola, G. et al. Growth and differentiation of myogenic clones from adult human muscle cell cultures. Eur. J. Basic. Appl. Histochem.35, 219–231 (1991). [PubMed] [Google Scholar]
  • 4.Hinkle, E. R., Essader, T. O., Gentile, G. M. & Giudice, J. ViaFuse: Fiji macros to calculate skeletal muscle cell viability and fusion index. Skelet Muscle11, 28 (2021). [DOI] [PMC free article] [PubMed]
  • 5.Kneppers, A. et al. AMPKα2 is a skeletal muscle stem cell intrinsic regulator of myonuclear accretion. iScience26, 12, 108343 (2023). [DOI] [PMC free article] [PubMed]
  • 6.Chaillou, T., Sanna, I. & Kadi, F. Glutamine-stimulated in vitro hypertrophy is preserved in muscle cells from older women. Mech Ageing Dev187, 111228 (2020). [DOI] [PubMed]
  • 7.Veliça, P. & Bunce, C. M. A quick, simple and unbiased method to quantify C2C12 myogenic differentiation. Muscle Nerve. 44, 366–370 (2011). [DOI] [PubMed] [Google Scholar]
  • 8.McColl, R., Nkosi, M., Snyman, C. & Niesler, C. Analysis and quantification of in vitro myoblast fusion using the LADD multiple stain. Biotechniques61, 323–326 (2016). [DOI] [PubMed] [Google Scholar]
  • 9.Murphy, D. P., Nicholson, T., Jones, S. W., O’Leary, M. F. MyoCount: a software tool for the automated quantification of myotube surface area and nuclear fusion index [version 1; peer review: 2 approved]. Wellcome Open. Res4:6 (2019). [DOI] [PMC free article] [PubMed]
  • 10.Noë, S. et al. The myotube analyzer: how to assess myogenic features in muscle stem cells. Skelet Muscle12, 12 (2022). [DOI] [PMC free article] [PubMed]
  • 11.Jeong, K. et al. SEPO-FI: Deep-learning based software to calculate fusion index of muscle cells. Comput. Biol. Med.186, 109706 (2025). [DOI] [PubMed] [Google Scholar]
  • 12.Stringer, C., Wang, T., Michaelos, M. & Pachitariu, M. Cellpose: a generalist algorithm for cellular segmentation. Nat. Methods. 18, 100–106 (2021). [DOI] [PubMed] [Google Scholar]
  • 13.Pachitariu, M. & Stringer, C. Cellpose 2.0: how to train your own model. Nat. Methods. 19, 1634–1641 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Cazorla, C., Morin, R. & Weiss, P. Svetlana a supervised segmentation classifier for Napari. Sci Rep14, 11604 (2024). [DOI] [PMC free article] [PubMed]
  • 15.Kase, E. T. et al. Primary defects in lipolysis and insulin action in skeletal muscle cells from type 2 diabetic individuals. Biochim. Et Biophys. Acta (BBA) - Mol. Cell. Biology Lipids. 1851, 1194–1201 (2015). [DOI] [PubMed] [Google Scholar]
  • 16.Løvsletten, N. G. et al. Primary defects in lipid handling and resistance to exercise in myotubes from obese donors with and without type 2 diabetes. Appl. Physiol. Nutr. Metab.45, 169–179 (2020). [DOI] [PubMed] [Google Scholar]
  • 17.Vion, J. et al. Metabolic and cardiovascular adaptations to an 8-wk lifestyle weight loss intervention in younger and older obese men. Am. J. Physiol.-Endocrinol. Metabol.321, E325–E337 (2021). [DOI] [PubMed] [Google Scholar]
  • 18.Badin, P. M. et al. Altered skeletal muscle lipase expression and activity contribute to insulin resistance in humans. Diabetes60, 1734–1742 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Laurens, C. et al. G0/G1 switch gene 2 controls adipose triglyceride lipase activity and lipid metabolism in skeletal muscle. Mol. Metab.5, 527–537 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Weisrock, A., Wüst, R., Olenic, M., Lecomte-Grosbras, P. & Thorrez, L. MyoFInDer: an AI-Based tool for myotube fusion index determination. Tissue Eng. Part. A. 30, 652–661 (2024). [DOI] [PubMed] [Google Scholar]
  • 21.Greenwald, N. F. et al. Whole-cell segmentation of tissue images with human-level performance using large-scale data annotation and deep learning. Nat. Biotechnol.40, 555–565 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Material 1 (808.4KB, pdf)

Data Availability Statement

The MyoFuse application with codes, model files, tutorials and test images can be found on the project home page: [https://github.com/BenLair/MyoFuse](https:/github.com/BenLair/MyoFuse). It is distributed under MIT License without any restrictions to use by non-academics.Images used to train the classifier and labels generated with the Svetlana plugin are available at: [https://zenodo.org/records/14731491](https:/zenodo.org/records/14731491). Other images, datasets and codes used in the current study are available from the corresponding authors upon reasonable request.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES