Abstract
Two-photon fluorescence excitation is being increasingly used in laser scan microscopy due to very low photodamage induced by this technique under normal operation. However, excitation intensity has to be kept low, because nonlinear photodamage sets in when laser power is increased above a certain threshold. We studied this kind of damage in bovine adrenal chromaffin cells, using two different indicators of damage: changes in resting [Ca(2+)] level and the degranulation reaction. In agreement with previous studies, we found that, for both criteria, damage is proportional to the integral (over space and time) of light intensity raised to a power approximately 2.5. Thus, widening the laser pulse shape at constant average intensity both in time and in focal volume is beneficial for avoiding this kind of damage. Both measures, of course, reduce the two-photon fluorescence excitation. However, loss of signal can be compensated by increasing excitation power, such that, at constant damaging potential, signals may be even larger with long pulses and large focal volumes, because the exponent of the power law of damage is higher (mu approximately 2.5) than that of the two-photon signal (mu approximately 2).
Full Text
The Full Text of this article is available as a PDF (90.7 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Booth M. J., Hell S. W. Continuous wave excitation two-photon fluorescence microscopy exemplified with the 647-nm ArKr laser line. J Microsc. 1998 Jun;190(Pt 3):298–304. doi: 10.1046/j.1365-2818.1998.00375.x. [DOI] [PubMed] [Google Scholar]
- Denk W., Strickler J. H., Webb W. W. Two-photon laser scanning fluorescence microscopy. Science. 1990 Apr 6;248(4951):73–76. doi: 10.1126/science.2321027. [DOI] [PubMed] [Google Scholar]
- Denk W., Svoboda K. Photon upmanship: why multiphoton imaging is more than a gimmick. Neuron. 1997 Mar;18(3):351–357. doi: 10.1016/s0896-6273(00)81237-4. [DOI] [PubMed] [Google Scholar]
- Koester H. J., Baur D., Uhl R., Hell S. W. Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamage. Biophys J. 1999 Oct;77(4):2226–2236. doi: 10.1016/S0006-3495(99)77063-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- König K., Liang H., Berns M. W., Tromberg B. J. Cell damage by near-IR microbeams. Nature. 1995 Sep 7;377(6544):20–21. doi: 10.1038/377020a0. [DOI] [PubMed] [Google Scholar]
- König K., Simon U., Halbhuber K. J. 3D resolved two-photon fluorescence microscopy of living cells using a modified confocal laser scanning microscope. Cell Mol Biol (Noisy-le-grand) 1996 Dec;42(8):1181–1194. [PubMed] [Google Scholar]
- Smith C. A persistent activity-dependent facilitation in chromaffin cells is caused by Ca2+ activation of protein kinase C. J Neurosci. 1999 Jan 15;19(2):589–598. doi: 10.1523/JNEUROSCI.19-02-00589.1999. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tan Y. P., Llano I., Hopt A., Würriehausen F., Neher E. Fast scanning and efficient photodetection in a simple two-photon microscope. J Neurosci Methods. 1999 Oct 15;92(1-2):123–135. doi: 10.1016/s0165-0270(99)00103-x. [DOI] [PubMed] [Google Scholar]
- Terakawa S., Fan J. H., Kumakura K., Ohara-Imaizumi M. Quantitative analysis of exocytosis directly visualized in living chromaffin cells. Neurosci Lett. 1991 Feb 11;123(1):82–86. doi: 10.1016/0304-3940(91)90163-n. [DOI] [PubMed] [Google Scholar]
- Williams R. M., Piston D. W., Webb W. W. Two-photon molecular excitation provides intrinsic 3-dimensional resolution for laser-based microscopy and microphotochemistry. FASEB J. 1994 Aug;8(11):804–813. doi: 10.1096/fasebj.8.11.8070629. [DOI] [PubMed] [Google Scholar]