Skip to main content
Biosensors logoLink to Biosensors
. 2026 Feb 28;16(3):141. doi: 10.3390/bios16030141

Correction: Bossi et al. Time-Resolved Fluorescence Spectroscopy of Molecularly Imprinted Nanoprobes as an Ultralow Detection Nanosensing Tool for Protein Contaminants. Biosensors 2023, 13, 745

Alessandra Maria Bossi 1,*, Alice Marinangeli 1,2, Alberto Quaranta 2,3, Lucio Pancheri 2, Devid Maniglio 2
PMCID: PMC13024176  PMID: 41892074

Error in Figure

In the original publication [1], there was a mistake in Figure 8. Specifically, the label reported in the grey bar on the x-axis as “Wine + 1.5 nM BSA” was incorrect and should be “Wine + 1.5 nM HSA”. The corrected Figure 8 appears below. The authors state that the scientific conclusions are unaffected. Moreover, in the originally published version, the vertical axis was labelled as τ2 (ns), which could be misleading. Although τ2 refers to a fluorescence lifetime component, the plotted values represent the relative variation expressed as a percentage contribution of the lifetime, rather than an absolute lifetime value in nanoseconds. For this reason, the vertical axis label has been revised in the corrected version as “Lifetime %” to indicate the percentage of lifetime variation, in order to accurately reflect the nature of the reported data.

Figure 8.

Figure 8

Real sample testing by means of 1×Fluo-nanoMIP nanosensors. White bars: wine sample; Gray bar: wine sample spiked with a known concentration of albumin; Dark-gray bar: wine sample spiked with a known concentration of HTR as an example of unrelated protein.

These corrections were approved by the Academic Editor. The original publication has also been updated.

Footnotes

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Reference

  • 1.Bossi A.M., Marinangeli A., Quaranta A., Pancheri L., Maniglio D. Time-Resolved Fluorescence Spectroscopy of Molecularly Imprinted Nanoprobes as an Ultralow Detection Nanosensing Tool for Protein Contaminants. Biosensors. 2023;13:745. doi: 10.3390/bios13070745. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Biosensors are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES