Skip to main content
The Journal of Physiology logoLink to The Journal of Physiology
. 1975 Jul;249(2):197–210. doi: 10.1113/jphysiol.1975.sp011011

Temperature dependence of the circulation pattern in the upper extremities.

E R Raman, V J Vanhuyse
PMCID: PMC1309570  PMID: 1177090

Abstract

1. The rate of blood flow D through the hand and the rate of heat H transferred by that blood flow into the hand were measured on eleven subjects between 18 and 22 years old. The hand was immersed in water, at temperatures ranging from 10 to 40 degrees C. 2. The rate of blood flow was measured with a water-air displacement plethysmograph, which was adapted also to give heat loss measurements. 3. Comparison of the relative values of D and H at different temperatures gives information about the change in distribution of blood flow with temperature. On decreasing water temperature, the change in distribution starts at about 25 degrees C and continues gradually to about 15 degrees C, suggesting that more and more blood is shunted to deep veins. For one of the subjects, no change in distrubiton pattern was found.

Full text

PDF
197

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BARGETON D., DURAND J., MENSCHDECHENE J., DECAUD J. Echanges de chaleur de la main; rôle des réactions circulatoires et des variations de la température locale du sang artériel. J Physiol (Paris) 1959 Jan-Feb;51(1):111–150. [PubMed] [Google Scholar]
  2. GASKELL P., BURTON A. C. Local postural vasomotor reflexes arising from the limb veins. Circ Res. 1953 Jan;1(1):27–39. doi: 10.1161/01.res.1.1.27. [DOI] [PubMed] [Google Scholar]
  3. Mendlowitz M. The Specific Heat of Human Blood. Science. 1948 Jan 23;107(2769):97–98. doi: 10.1126/science.107.2769.97. [DOI] [PubMed] [Google Scholar]
  4. Mitchell J. W., Myers G. E. An analytical model of the counter-current heat exchange phenomena. Biophys J. 1968 Aug;8(8):897–911. doi: 10.1016/S0006-3495(68)86527-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Raman E. R., Vanhuyse V. J., Jageneau A. H. Comparison of plethysmographic and electromagnetic flow measurements. Phys Med Biol. 1973 Sep;18(5):704–711. doi: 10.1088/0031-9155/18/5/309. [DOI] [PubMed] [Google Scholar]
  6. Vanhuyse V. J., Raman E. R. Temperature dependence of pressure change in plethysmography. Phys Med Biol. 1972 Mar;17(2):288–292. doi: 10.1088/0031-9155/17/2/014. [DOI] [PubMed] [Google Scholar]

Articles from The Journal of Physiology are provided here courtesy of The Physiological Society

RESOURCES