Biomechanical study of robot-navigated targeted cross-puncture percutaneous vertebroplasty for Kümmell's disease: finite element analysis

Haibin Zhou 1,2, Chunjiu Gao 1, Xiaoyuan Zhang 1,2, Bao Chen 1,2, Xiao Meng 1, Yifeng Liao 1, Xuebin Tang 1, Hua Li 1, Yunqing Wang 1,*
PMCID: PMC13099861  PMID: 42028149

Abstract

Objective

The objective of this study is to utilize finite element analysis (FEA) to compare the biomechanical advantages and disadvantages of bone cement distribution patterns during robot-navigated targeted cross-puncture percutaneous vertebroplasty (PVP) for osteoporotic vertebral compression fractures (OVCF) complicated by Kümmell's disease.

Method

A patient-specific finite element model of the T12–L2 segment was developed from CT data to simulate L1 Kümmell's disease with an intravertebral vacuum cleft (IVC). The model simulated two surgical approaches: conventional percutaneous vertebroplasty (CPVP; cement filling was limited to the IVC) and robot-navigated targeted cross-puncture PVP (RPVP; incorporating a subjacent cancellous bone cement anchor). Material properties were assigned, and the lower surface of the L2 vertebral body was fully constrained to define the boundary conditions. Subsequently, six physiological loading conditions (flexion, extension, left/right lateral bending, and left/right axial rotation) were applied under a combined load of 500 N compressive preload and 7.5 N·m moment. Biomechanical outcomes included the von Mises stress distribution in the bone cement, vertebral body, and T12 inferior endplate, as well as the relative displacements.

Results

Compared to CPVP, RPVP demonstrated superior biomechanical stability, evidenced by significantly reduced cement displacement and improved segmental stability in the T12–L2 functional spinal unit. RPVP also lowered peak vertebral stress in the vertebral body of L1, suggesting enhanced load distribution. A trade-off was observed: RPVP increased stress concentrations within the cement itself and at the T12 inferior endplate. Critically, lateral bending induced the greatest instability in both techniques, highlighting the necessity for postoperative movement restrictions in this plane.

Conclusion

RPVP significantly reduces cement migration risk during Kümmell's disease treatment through optimized cement distribution. This biomechanical optimization establishes RPVP as a viable alternative to CPVP, enhancing surgical precision and stability while expanding clinical options for vertebral augmentation.

Keywords: finite element analysis, Kümmell's disease, orthopedic navigation robot, percutaneous vertebroplasty, targeted cross-puncture

1. Introduction

Kümmell's disease, formally classified as delayed post-traumatic vertebral osteonecrosis, represents an uncommon complication of OVCF characterized by progressive collapse following initial injury healing. This condition manifests after varied latency periods—ranging from weeks to years—following an initial vertebral fracture event, attributed to avascular necrosis at the fracture site (13). During the subacute phase, patients often present with insidious symptom onset characterized by progressive manifestations: persistent mechanical low back pain, worsening kyphotic deformity, radicular symptoms (lower extremity pain/numbness), neurogenic bladder/bowel dysfunction, and potential motor deficits in advanced stages (4, 5). The diagnostic imaging triad includes vertebral body collapse with loss of anterior/posterior height ratio, IVC on spine radiographs, and “Double-line sign” on T2-weighted MRI (57). Amid accelerated global demographic aging, Kümmell's disease affects 7%–37% of OVCF patients, representing an established late complication in approximately one-third of this population (8, 9). Consequently, Kümmell's disease substantially compromises functional independence in elderly patients through progressive vertebral collapse and neurological sequelae, leading to significant deterioration in quality-of-life indices including mobility, pain control, and daily living activities.

For patients with Stage I–II Kümmell's disease without significant neurological compromise, PVP has become a primary minimally invasive treatment option aimed at stabilizing the fractured vertebra, alleviating pain, and preventing further collapse (1013). However, CPVP has inherent limitations. When bone cement is injected into the IVC, it is difficult to fully interlock and fuse with the underlying cancellous bone, and it tends to form clumps, leading to stress concentration and postoperative loosening of the bone cement. The incidence rate is as high as 25%, and some patients even require revision surgery (14).

In recent years, with the widespread application of orthopedic surgical navigation robots, a new technology-robot-navigated targeted cross-puncture percutaneous vertebroplasty (RPVP) has emerged. Through real-time visual guidance, this technology enables precise puncture. It can not only completely fill the bone cement into the IVC but also further penetrate into the healthy cancellous bone area below the fissure, forming a “cross-fissure cement anchoring” biomechanical anchoring structure. This “cross—fissure anchoring” mode helps to disperse the load, reduce the risk of bone cement displacement, and enhance the overall stability of the vertebral body. In addition, RPVP can be completed under local anesthesia, reducing repeated fluoroscopy exposure and improving the safety and efficiency of the surgery. Although clinical studies have shown that RPVP has good curative effects, there is currently a lack of systematic biomechanical analysis to clarify its mechanism of action. Therefore, this study aims to use the finite element analysis method to compare the biomechanical characteristics of RPVP and CPVP in the treatment of OVCF complicated with Kümmell's disease. The focus is on evaluating the impact of the intra-vertebral anchoring structure on the stability of bone cement, the stress distribution of the vertebral body, and the load of adjacent segments, so as to provide a mechanistic validation for the clinical application of this technology.

2. Materials and methods

2.1. Data scanning and modeling

A 69-year-old male with L1 Kümmell's disease (symptom duration: 3 months) was prospectively enrolled from our spine surgery department in 2024. Upon admission, comprehensive baseline screening encompassed physical examination, radiographic assessment (x-ray/CT), and laboratory tests to exclude spinal deformities, neoplasms, and infectious processes. A 64-slice helical CT scan of the T12–L2 segment provided DICOM data for patient-specific finite element model reconstruction. Written informed consent was obtained after full explanation of experimental protocols prior to study initiation.

2.2. Establishment of L1 Kümmell disease model

Thin-slice CT scanning was performed using a 64-slice spiral CT scanner (GE Company), covering the range from T12–L2. The scanning parameters were set as follows: 140 kv, 200 mA, slice thickness of 0.625 mm, and no interval (15, 16). DICOM data were imported into Mimics software (version 21.0, Materialise company, Leuven, Belgium) for 3D reconstruction. Using Hounsfield unit (HU) threshold-based segmentation, a T12–L2 finite element model was generated through mask editing operations (region growing/erasing) and exported in STL format. Geomagic Wrap 2021 software (Geomagic, USA) processing entailed sequential mesh optimization (remeshing/spike removal/surface smoothing), anatomical facet refinement via digital sculpting, and NURBS surface reconstruction following precise contour modeling. Cortical and cancellous bone regions were segmented using a global offset (−1 mm), generating STL-format models of T12–L2 vertebral structures. Anatomically accurate surface models were reconstructed in SolidWorks 2020 software (Dassault Systemes Company, USA) based on T12–L2 morphology. Vertebral endplates (T12 inferior, L1 superior/inferior, L2 superior) and intervertebral discs were modeled, with Boolean operations creating nucleus pulposus (43% disc volume) and annulus fibrosus compartments (17). An IVC was established by resecting the anterior two-thirds of L1. Ligamentous structures—including anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), ligamentum flavum (LF), capsular ligament (CL), intertransverse ligament (ITL), interspinous ligaments (ISL), and supraspinous ligament (SSL)—were simulated using LINK180 elements in ANSYS Workbench 20 (USA). Finally, the above-generated model was assembled into a complete osteoporotic vertebral body model of the T12–L2 segment (18). As shown in Figure 1.

Figure 1.

Three-dimensional illustration of three vertebrae segments labeled A, B, and C, each viewed from different angles and colored gray, green, and blue, with coiled wires running vertically alongside each side for anatomical comparison.

T12–L2 vertebral model including the anterior longitudinal ligament, posterior longitudinal ligament, ligamentum flavum, articular capsule ligament, intertransverse ligament, interspinous ligament, and supraspinous ligament. (A) lateral view; (B) front view; (C) rear view.

2.3. Bone cement distribution modeling

One or two simulated bone cement cylinders were implanted into the fractured L1 vertebral body to simulate cement distribution patterns. For CPVP, a single 4 mL cement cylinder was positioned with its centroid at the anterior third of the vertebral body, completely occupying the IVC. The RPVP incorporated an additional 1.5 mL cement cylinder injected into subjacent cancellous bone—also centered at the anterior third—establishing mechanical anchoring within the vertebral body. As shown in Figure 2.

Figure 2.

Panel A shows a colored 3D rendering of spinal vertebrae with three discs between them, depicted in blue, yellow, and green. Panel B shows the same anatomy but missing the yellow disc, illustrating a difference in disc composition.

Bone cement distribution model (A: RPVP; B: CPVP). Blue indicates that the bone cement completely fills the IVC, and yellow indicates the bone cement in the cancellous bone below the IVC.

2.4. Handling of model meshing

Both model datasets were imported into HyperMesh software(Altair Engineering) for body meshing. Given the complex geometry of vertebral structures, tetrahedral Solid187 elements were selected to accommodate anatomical irregularities. The mesh size of all the cells was set to 1 mm, and the number of nodes and cells generated by the two T12–L2 segmental finite element models are shown in Table 1.

Table 1.

Number of nodes and cells generated for the spine finite element model.

Groups Node number Cell number
RPVP 1,90,668 44,110
CPVP 1,91,235 44,742

2.5. Material parameters

Referring to previous literature (1925), the material property parameters for cortical bone, cancellous bone, injured vertebral cortical bone, injured vertebral cancellous bone, upper and lower endplates, nucleus pulposus, annulus fibrosus, bone cement, and related ligament materials in the model are assigned as shown in Table 2.

Table 2.

Material parameters of the finite element model.

Materials Modulus of elasticity (MPa) Poisson ratio Stiffness (N·mm)
Normal cortical bone 12,000 0.3
Osteoporotic cortical bone 8,040 0.3
Normal cancellous bone 132 0.2
Osteoporotic cancellous bone 34 0.2
Normal end plate 1,000 0.4
Osteoporotic endplate 670 0.4
Nucleus pulposus 1.0 0.49
Fibrous ring matrix 4.2 0.45
Anterior longitudinal ligament 8.74
Posterior longitudinal ligament 5.82
Yellow ligament 15.75
Joint capsule ligament 10.85
Transverse ligament 15.38
Intervertebral ligament 0.19
Superior spinal ligament 2.39
PMMA 3,000 0.4

2.6. Boundary conditions and load settings

Finite element meshing and material property assignment were performed using HyperMesh software. The T12–L2 vertebral model was exported in CDB format and imported into ANSYS Mechanical (2020 R1, ANSYS Inc.) for biomechanical simulation under standing posture conditions, with applied loads and boundary constraints defined per established protocols.

The interfaces between cortical and cancellous bone, nucleus pulposus and annulus fibrosus, bone cement and cancellous bone, bone cement and itself, vertebral body and disc components, intervertebral disc and endplate, as well as cortical bone and endplate, were defined as bonded contacts. The relationship between the small joints and the posterior structures is set as a non-separable contact relationship, with a friction coefficient of 0.1. The lower surface of the L2 vertebral body is set as fully constrained to define the boundary conditions; a vertical load of 500 N is applied to the upper surface of the T12 vertebral body to simulate the standing posture. Additionally, a torque of 7.5 Nm is applied in the +X direction to simulate flexion, and in the −X direction to simulate extension; torque applied in the +Y and −Y directions simulates left and right bending, respectively; torque applied in the +Z and −Z directions simulates left and right rotation, respectively.

2.7. Observation indicators

Under varying loading conditions, the following biomechanical parameters were quantified: peak Von Mises stress at the T12 inferior endplate; maximum Von Mises stress and relative displacement of bone cement within the L1 vertebral body; pk Von Mises stress in the L1 vertebral body; and maximum relative displacement of the T12–L2 functional spinal unit.

2.8. Key observation indicators

Under different loads, the maximum Von Mises stress was observed in the L1 vertebrae of the two models mentioned above and in the injected bone cement. Von Mises stress is obtained based on the principal stresses in three directions (X, Y, and Z directions), and the calculation method is as follows:

σ=[(σ1σ2)2+(σ2σ3)2+(σ3σ1)2]/2.

Where σ is the Von Mises stress, and σ 1, σ 2, and σ 3 are the principal stresses in the X, Y, and Z directions of the model, respectively.

3. Results

3.1. Validation of the finite element analysis model

The L1 Kümmell's disease finite element model was validated under six loading directions (flexion, extension, left/right lateral bending, and left/right axial rotation). The resulting T12–L2 range of motion (ROM) data demonstrated close agreement with established biomechanical studies, confirming model validity for simulating post-PVP biomechanics (26, 27). As shown in Figure 3.

Figure 3.

Panel A shows a grouped bar chart comparing flexion, extension, left bending, right bending, left rotation, and right rotation across three studies labeled present study, Lu’s study, and Zhong’s study. Panel B shows a grouped bar chart comparing the same six motion categories between CPVP and RPV P, with CPVP values generally higher. Panel C displays a grouped bar chart for the same motions, comparing CPVP and RPV P, with close values for most categories. Panel D presents another grouped bar chart with CPVP and RPV P data, all values under one. Panel E shows CPVP and RPV P comparisons, with left and right bending higher than other motions. Panel F illustrates CPVP and RPV P comparisons with highest values for flexion, left bending, and right bending.

(A) Comparison of the range of motion (ROM) of T12–L2 in the model produced in this study with previously reported data. (B) Histogram of the maximum Von Mises stresses in the L1 vertebrae of the models. (C) Histogram of the maximum Von Mises stress in bone cement. (D) Histogram of the maximum relative displacement distance in bone cement. (E) Relative displacement distance cloud of the T12–L2 functional spinal unit. (F) Histogram of the maximum Von Mises stress on the T12 inferior endplate.

3.2. Peak Von Mises stress distribution in L1 vertebral body

Maximum Von Mises stress contour plots for the L1 vertebrae in the two groups are shown in the Figure 4. The computational results and statistical histograms after applying the same load are shown in the Figure 3 and Table 3. Based on these results, the stress distributions in the two groups differ significantly under flexion, extension, lateral flexion, and rotation conditions. In contrast, the maximum Von Mises stress values of the L1 vertebra in the RPVP are lower than those in the CPVP under flexion, extension, lateral flexion, and axial rotation conditions, indicating better relative stability of the L1 vertebra. The stress values are as follows: flexion, 30.130 MPa; extension, 32.247 MPa; left lateral flexion, 23.342 MPa; right lateral flexion, 22.350 MPa; left axial rotation, 21.996 MPa; and right axial rotation, 16.883 MPa.

Figure 4.

Composite scientific figure displaying five labeled groups (A-E), each with CPVP and RPVPP model comparisons, shown in six spinal motion states: flexion, extension, left bending, right bending, left rotation, right rotation. Each group visualizes colored finite element heat maps on anatomical or cylindrical structures reflecting differing mechanical responses for the two models across conditions.

(A) Stress clouds of L1 vertebrae in flexion, extension, left/right lateral bending, and left/right axial rotation in two sets of models. (B) Stress clouds of bone cement in flexion, extension, left/right lateral bending, and left/right axial rotation in two sets of models. (C) Displacement clouds of bone cement in flexion, extension, left/right lateral bending, and left/right axial rotation in two sets of models. (D) Displacement clouds of the T12-L2 functional spinal unit in flexion, extension, left/right lateral bending, and left/right axial rotation in two sets of models. (E) Stress clouds of the T12 inferior endplate in flexion, extension, left/right lateral bending, and left/right axial rotation in two sets of models.

Table 3.

(A) Maximum Von mises stresses in the vertebral body of both models after percutaneous vertebroplasty for L1 fracture. (B) Maximum Von Mises stress of bone cement within the vertebral body following percutaneous vertebroplasty for L1 fractures. (C) Maximum relative displacement of bone cement in the vertebral body following percutaneous vertebroplasty for L1 fractures. (D) Maximum relative displacement of the T12–L2 functional spinal unit following percutaneous vertebroplasty for L1 fractures. (E) Maximum Von Mises stress at the inferior endplate of T12 following percutaneous vertebroplasty for L1 fractures.

Groups Flexion Extension Left bending Right bending Left rotation Right rotation
A CPVP 37.427 38.138 25.060 27.840 26.635 20.774
RPVP 30.130 32.247 23.342 22.350 21.996 16.883
B CPVP 0.841 0.310 0.542 0.771 0.548 0.436
RPVP 0.859 0.349 0.543 0.791 0.562 0.473
C CPVP 0.4579 0.2986 0.6885 0.7602 0.5756 0.6235
RPVP 0.4554 0.2975 0.6778 0.7461 0.5596 0.6124
D CPVP 0.9654 0.7324 1.7506 1.9023 0.7737 0.7430
RPVP 0.9637 0.7304 1.7474 1.8948 0.7679 0.7346
E CPVP 4.3785 0.5873 4.0916 4.2323 2.6153 2.0522
RPVP 4.3997 0.5791 4.1700 4.3236 2.6369 2.0717

3.3. Von Mises stress and displacement distance of bone cement in the L1 vertebral body

The maximum Von Mises stress distribution maps of bone cement in the L1 vertebrae of the two groups are shown in the Figure 4. The computational results and statistical histograms after applying the same load are shown in the Figure 3 and Table 3. Based on these results, there are significant differences in stress distribution between the two groups under conditions of flexion, extension, lateral flexion, and axial rotation. In contrast, the maximum Von Mises stress values of bone cement in the L1 vertebrae of the RPVP were higher than those of the CPVP during flexion, extension, left/right lateral bending, and left/right axial rotation, indicating that bone cement in the RPVP bore more stress. The stress values are as follows: flexion, 0.8590 MPa; extension, 0.3485 MPa; left lateral flexion, 0.5426 MPa; right lateral flexion, 0.7910 MPa; left axial rotation, 0.5621 MPa; and right axial rotation, 0.4734 MPa.

After loading the same load, the maximum relative displacement distance of the L1 vertebral body in the RPVP was smaller than that in the CPVP under flexion, extension, lateral flexion, and rotation conditions, as shown in the Figures 3, 4 and Table 3, indicating that the RPVP had better bone cement stability and a lower risk of bone cement loosening or displacement under various conditions. The relative displacement distances of bone cement between the RPVP and the CPVP were as follows: flexion, −0.0025 mm; extension, −0.0011 mm; left lateral flexion, −0.0107 mm; right lateral flexion, −0.0141 mm; left axial rotation, 0.0160 mm; and right axial rotation, −0.0111 mm.

3.4. Total maximum relative displacement distance between T12 and L2

The displacement distances between the two groups under flexion, extension, lateral bending, and axial rotation showed no significant differences. As shown in Figures 3, 4, and Table 3. In contrast, the overall maximum relative displacement distances in the RPVP were slightly smaller than those in the CPVP during flexion, extension, lateral flexion, and axial rotation, indicating better overall stability in the RPVP. The displacement distances were as follows: flexion, −0.0017 mm; extension, −0.0020 mm; left lateral flexion, −0.002 mm; right lateral flexion, −0.0075 mm; left axial rotation, 0.0058 mm; and right axial rotation, −0.0084 mm.

3.5. Maximum Von Mises stress at the bottom plate under T12

The maximum Von Mises stress contour plots of the T12 endplate in the two groups are shown in the Figure 4. The computational results and statistical histograms after applying the same load are shown in the Figure 3 and Table 3. Based on these results, the stress distributions under flexion, extension, lateral flexion, and axial rotation conditions are similar between the two groups. In contrast, the maximum Von Mises stress value at the endplate of T12 in the RPVP was slightly higher than that in the control group, indicating that the Von Mises stress value on the T12 vertebral body in the RPVP was slightly higher than that in the CPVP. The stress values are as follows: flexion, 4.3997 MPa; extension, 0.5791 MPa; left lateral flexion, 4.1700 MPa; right lateral flexion, 4.3236 MPa; left axial rotation, 2.6369 MPa; and right axial rotation, 2.0717 MPa.

4. Discussion

Kümmell disease was first described by German surgeon Hermann Kümmell in 1895. In this condition, the blood supply to the anterior third of the vertebral body primarily originates from a single terminal artery. In patients with osteoporosis, even minor trauma can easily disrupt blood flow to this region, leading to non-union of fractures in the anterior third of the vertebral body. This, in turn, causes local ischemia and bone necrosis. Kümmell disease is also known as delayed ischemic osteonecrosis, ultimately resulting in vertebral compression collapse (28, 29). Initially, it was believed that conservative treatment could be prioritized when Kümmell disease presented without significant neurological symptoms. However, given that osteonecrosis leads to nonunion of the vertebral body, which cannot heal spontaneously (forming an IVC), conservative treatment typically fails to produce satisfactory outcomes. Additionally, vertebral compression collapse and kyphosis pose a high risk of neurological dysfunction, making surgical intervention necessary (30). With the rapid advancement of minimally invasive techniques, for patients with Stage I and II Kümmell disease who have not yet developed significant neurological symptoms, the use of bone cement to fully fill the IVC and restore vertebral strength represents the least invasive and safest treatment option for Kümmell disease. Therefore, PVP is one of the primary minimally invasive surgical treatment modalities (31). The aim is to eliminate IVC and restore the biomechanical properties of the vertebrae, alleviate pain, prevent the progression of kyphotic deformity, enable a swift return to normal daily activities, and avoid prolonged bed rest (32).

Research indicates that IVC is an independent risk factor for re-fracture of the injured vertebra in OVCF patients following PVA surgery, and it is also the primary determinant of bone cement leakage risk (33, 34). Therefore, with the widespread application of PVP technology, issues such as bone cement leakage, postoperative bone cement loosening, and further compression collapse of the vertebral body have emerged, and in severe cases, catastrophic complications such as bone cement displacement may occur (34, 35). In cases of bone cement displacement, surgeons typically need to perform revision surgery on the injured vertebrae via anterior, posterior, or combined approaches to remove the bone cement and restore spinal stability, thereby reducing back pain in patients. This can cause greater trauma for elderly patients, and those with multiple underlying conditions may not tolerate surgery. Additionally, bed rest can further accelerate osteoporosis in elderly patients, severely impacting their quality of life in later years. CPVP uses bone cement to fill the IVC until the fissure is completely filled. Reactive sclerotic bone forms around the necrotic vertebra, and the bone cement cannot diffuse well into the cancellous bone, forming clumps that do not anchor well (34). Furthermore, in patients with osteoporotic vertebral compression fractures, the trabecular bone beneath the fracture gap is fragile and sparse, failing to provide adequate support for the bone cement. The high stress from the bone cement can lead to further compression and collapse of the injured vertebra, significantly impairing the long-term efficacy of the surgery and patient satisfaction with PVP. Currently, to address cement loosening or displacement, some scholars have adopted PVP combined with pedicle fixation, i.e., injecting cement into the IVC followed by injection into the pedicle to create a “tail sign”, which can enhance cement stability to some extent (36, 37). However, this technique heavily relies on the surgeon's experience and skill. If the pedicle is perforated during surgery or is already damaged or fractured, the bone cement is highly likely to leak into the spinal canal. In mild cases, this may cause artificial spinal stenosis and stimulate spinal nerves; in severe cases, open surgery may be required to remove the bone cement and perform spinal decompression surgery. Additionally, since the anchored bone cement forms a horizontal arm with the bone cement in the IVC, significant stress is distributed across the horizontal arm of the bone cement, posing a risk of fracture. The effect of counteracting the sinking of the bone cement mass is relatively limited. Furthermore, some scholars have employed unilateral or bilateral pedicle screws combined with PVP for Kümmell disease treatment (38). This technique requires general anesthesia and involves the dissection of muscles and fascia during surgery, resulting in significant trauma. Given that elderly patients often have multiple underlying conditions, this approach inevitably increases various risks for patients and is not suitable for those who cannot tolerate surgery.

With the widespread adoption of minimally invasive concepts and the extensive application of orthopedic surgical navigation robots, we are not only able to precisely access the IVC under visualization, but also, when necessary, provide gelatin sponge filling at the site of cortical bone fractures to reduce the occurrence of bone cement leakage. Additionally, we can precisely access the cancellous bone below the IVC, achieving bilateral pedicle cross-puncture to secure the vertebral body, thereby achieving the “top-to-bottom” effect. We refer to this as the RPVP technique, which can be performed under local anesthesia and does not require repeated fluoroscopy under the assistance of orthopedic navigation robots, offering greater benefits to both patients and medical staff. The RPVP technique involves completely sealing the IVC and injecting bone cement into the cancellous bone below the fissure cavity, providing upward support for the bone cement within the IVC. This slows down further compression and collapse of the vertebral body, indirectly enhancing bone cement anchorage and vertebral stability. However, there is a lack of biomechanical studies elucidating the underlying mechanisms.

This study utilized finite element analysis to investigate the biomechanical effects of vertebral body anchoring on injured vertebrae, focusing on the biomechanical characteristics of spinal surgery in daily life. The results of this study showed that the maximum Von Mises stress value of the L1 vertebra in the RPVP was lower than that in the CPVP, indicating that the postoperative stability of the surgical vertebra was better in the RPVP. Due to the block-like distribution of bone cement within the IVC, stress concentration occurs, and since the RPVP received a greater volume of bone cement, the bone cement in the RPVP endures greater stress than that in the CPVP. Under identical loading conditions, the bone cement in the RPVP can absorb part of the stress, thereby enhancing the stability of the injured vertebra post-surgery. The results of this study show that under various load conditions, the maximum relative displacement distance of bone cement in the RPVP was smaller than that in the CPVP, suggesting that the bone cement in the RPVP had better stability, a lower risk of loosening or displacement, and a better prognosis. Additionally, under the same load conditions, the maximum displacement distance of the T12–L2 segment in the RPVP was slightly smaller than that in the CPVP, indicating better overall stability of the vertebral bodies. However, we observed a slightly higher maximum Von Mises stress at the T12 inferior endplate in the RPVP group, indicating a potentially increased biomechanical load on the adjacent cranial segment compared to CPVP. Studies have shown that IVC itself is one of the risk factors for adjacent vertebral fractures, and simultaneously, bone cement leakage into the intervertebral disc is also one of the important risk factors for adjacent vertebral fractures. The results of this study also showed that under the hyperextension condition, the maximum Von Mises stress at the T12 endplate was significantly lower than under other conditions. Since the bone cement mass was located in the anterior 2/3 of the L1 vertebral body, this result indirectly confirmed that the stress concentration of the bone cement mass has a greater impact on adjacent vertebrae. Additionally, we found that, regardless of whether it was the maximum relative displacement of bone cement within the injured vertebra or the overall maximum relative displacement between T12 and L2, the relative displacement was the largest and stability was the poorest under left and right lateral bending conditions compared to other conditions. Therefore, for patients with Kummell's disease, post-operative restrictions on lateral bending activities should be given greater attention.

This study still has limitations: first, only one patient was selected, and finite element analysis was used, so the data results lack universality and may be biased due to individual differences. Second, the simulated working conditions were only for everyday standing positions, and the results cannot be predicted if a greater force is suddenly applied. The next step in the research should be to utilize high-resolution imaging and advanced segmentation techniques to perform more detailed, patient-specific reconstructions of IVC morphology. Meanwhile, finite element analysis should be pursued using multiple actual IVCs from patients with Kümmell's disease.

5. Conclusion

Under the guidance of an orthopedic navigation robot, targeted cross-puncture can effectively prevent cement loosening and displacement during the treatment of Kümmell disease. This modified surgical procedure offers a reliable treatment option for PVP in the management of Kümmell disease, providing patients with an additional clinical choice for treatment.

Funding Statement

The author(s) declared that financial support was received for this work and/or its publication. 2024 Jiangsu Province Graduate Student Practical Innovation Program (SJCX24_1533).

Footnotes

Edited by: Tosan Okoro, Robert Jones and Agnes Hunt Orthopaedic Hospital, United Kingdom

Reviewed by: Hao-Li Zhang, Ankang Traditional Chinese Medicine Hospital, China

Yu Qiao, Technical University of Munich, Germany

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.

Ethics statement

The studies involving humans were approved by The Second Affiliated Hospital of Xuzhou Medical University. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

HZ: Funding acquisition, Software, Writing – original draft, Writing – review & editing. CG: Conceptualization, Data curation, Writing – review & editing. XZ: Conceptualization, Data curation, Writing – review & editing. BC: Conceptualization, Data curation, Writing – review & editing. XM: Methodology, Writing – review & editing. YL: Methodology, Writing – review & editing. XT: Validation, Writing – review & editing. HL: Validation, Writing – review & editing. YW: Methodology, Supervision, Writing – review & editing.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1.Tsujio T, Nakamura H, Terai H, Hoshino M, Namikawa T, Matsumura A, et al. Characteristic radiographic or magnetic resonance images of fresh osteoporotic vertebral fractures predicting potential risk for nonunion: a prospective multicenter study. Spine. (2011) 36(15):1229–35. 10.1097/BRS.0b013e3181f29e8d [DOI] [PubMed] [Google Scholar]
  • 2.Kim YC, Kim YH, Ha KY. Pathomechanism of intravertebral clefts in osteoporotic compression fractures of the spine. Spine J. (2014) 14(4):659–66. 10.1016/j.spinee.2013.06.106 [DOI] [PubMed] [Google Scholar]
  • 3.Kim HS, Adsul N, Bang JS, Singh R, Park CH, Jang IT. Refracture of kummell disease combined with huge epidural hematoma after Minor trauma. World Neurosurg. (2018) 120:500–5. 10.1016/j.wneu.2018.09.130 [DOI] [PubMed] [Google Scholar]
  • 4.Ma R, Chow R, Shen FH. Kummell’s disease: delayed post-traumatic osteonecrosis of the vertebral body. Eur Spine J. (2010) 19(7):1065–70. 10.1007/s00586-009-1205-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Qin GB, Wu YH, Chen HS, Huang YT, Yi JF, Xiao Y. Correlation analysis between morphologic characteristics of the thoracolumbar basivertebral foramen and Kummell’s disease in patients with osteoporosis using imaging techniques. BMC Musculoskelet Disord. (2023) 24(1):513. 10.1186/s12891-023-06609-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Pappou IP, Papadopoulos EC, Swanson AN, Cammisa FP Jr., Girardi FP. Osteoporotic vertebral fractures and collapse with intravertebral vacuum sign (Kümmel’s disease). Orthopedics. (2008) 31(1):61–6. 10.3928/01477447-20080101-35 [DOI] [PubMed] [Google Scholar]
  • 7.Lee SH, Kim ES, Eoh W. Cement augmented anterior reconstruction with short posterior instrumentation: a less invasive surgical option for Kummell’s disease with cord compression. J Clin Neurosci. (2011) 18(4):509–14. 10.1016/j.jocn.2010.07.139 [DOI] [PubMed] [Google Scholar]
  • 8.Fang X, Yu F, Fu S, Song H. Intravertebral clefts in osteoporotic compression fractures of the spine: incidence, characteristics, and therapeutic efficacy. Int J Clin Exp Med. (2015) 8(9):16960–8. PMID: [PMC free article] [PubMed] [Google Scholar]
  • 9.Wu X-f, Ping Y, Zeng X-q, Feng Y, Wang Z, Li T, et al. Percutaneous vertebroplasty with side-opening cannula or front-opening cannula in the treatment of Kummell disease? Orthop Surg. (2020) 12(4):e12730. 10.1111/os.12730 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Liu F, Chen Z, Lou C, Yu W, Zheng L, He D, et al. Anterior reconstruction versus posterior osteotomy in treating Kümmell’s disease with neurological deficits: a systematic review. Acta Orthop Traumatol Turc. (2018) 52(4):283–8. 10.1016/j.aott.2018.05.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Svedbom A, Alvares L, Cooper C, Marsh D, Ström O. Balloon kyphoplasty compared to vertebroplasty and nonsurgical management in patients hospitalised with acute osteoporotic vertebral compression fracture: a UK cost-effectiveness analysis. Osteoporos Int. (2013) 24(1):355–67. 10.1007/s00198-012-2102-y [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.D'Oria S, Delvecchio C, Dibenedetto M, Zizza F, Somma C. Case report of Kummell’s disease with delayed onset myelopathy and the literature review. Eur J Orthop Surg Traumatol. (2018) 28(2):309–16. 10.1007/s00590-017-2039-0 [DOI] [PubMed] [Google Scholar]
  • 13.Huang X, Chang H, Xu H, Chen X, Wang H, Song Y. Comparison of outcomes between percutaneous vertebroplasty and percutaneous kyphoplasty for the treatment of Kümmell’s disease: a meta-analysis. Clin Spine Surg. (2022) 35(6):276–86. 10.1097/BSD.0000000000001269 [DOI] [PubMed] [Google Scholar]
  • 14.Nakamae T, Yamada K, Tsuchida Y, Osti OL, Adachi N, Fujimoto Y. Risk factors for cement loosening after vertebroplasty for osteoporotic vertebral fracture with intravertebral cleft: a retrospective analysis. Asian Spine J. (2018) 12(5):935–42. 10.31616/asj.2018.12.5.935 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Widmer Soyka RP, Helgason B, Hazrati Marangalou J, van den Bergh JP, van Rietbergen B, Ferguson SJ. The effectiveness of percutaneous vertebroplasty is determined by the patient-specific bone condition and the treatment strategy. PLoS One. (2016) 11(4):e0151680. 10.1371/journal.pone.0151680 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Liu Y, Zhang A, Wang C, Yin W, Wu N, Chen H, et al. Biomechanical comparison between metal block and cement-screw techniques for the treatment of tibial bone defects in total knee arthroplasty based on finite element analysis. Comput Biol Med. (2020) 125:104006. 10.1016/j.compbiomed.2020.104006 [DOI] [PubMed] [Google Scholar]
  • 17.Zhou C, Meng X, Huang S, Chen H, Zhou H, Liao Y, et al. Biomechanical study of different bone cement distribution on osteoporotic vertebral compression fracture-A finite element analysis. Heliyon. (2024) 10(5):e26726. 10.1016/j.heliyon.2024.e26726 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Peng Y, Du X, Huang L, Li J, Zhan R, Wang W, et al. Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling. Med Biol Eng Comput. (2018) 56(11):2137–50. 10.1007/s11517-018-1844-x [DOI] [PubMed] [Google Scholar]
  • 19.Zhang X, Chen T, Meng F, Li S, Xu G, Yan J, et al. A finite element analysis on different bone cement forms and injection volumes injected into lumbar vertebral body in percutaneous kyphoplasty. BMC Musculoskelet Disord. (2022) 23(1):621. 10.1186/s12891-022-05522-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Liang D, Ye LQ, Jiang XB, Yang P, Zhou GQ, Yao ZS, et al. Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis. J Surg Res. (2015) 195(1):246–56. 10.1016/j.jss.2014.12.053 [DOI] [PubMed] [Google Scholar]
  • 21.Zhao W-T, Qin D-P, Zhang X-G, Wang Z-P, Tong Z. Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis. J Orthop Surg Res. (2018) 13(1):32. 10.1186/s13018-018-0733-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Bereczki F, Turbucz M, Kiss R, Eltes PE, Lazary A. Stability evaluation of different oblique lumbar interbody fusion constructs in normal and osteoporotic condition—a finite element based study. Front Bioeng Biotechnol. (2021) 9:749914. 10.3389/fbioe.2021.749914 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Salvatore G, Berton A, Giambini H, Ciuffreda M, Florio P, Longo UG, et al. Biomechanical effects of metastasis in the osteoporotic lumbar spine: a finite element analysis. BMC Musculoskelet Disord. (2018) 19(1):38. 10.1186/s12891-018-1953-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Zhang Q, Chon T, Zhang Y, Baker JS, Gu Y. Finite element analysis of the lumbar spine in adolescent idiopathic scoliosis subjected to different loads. Comput Biol Med. (2021) 136:104745. 10.1016/j.compbiomed.2021.104745 [DOI] [PubMed] [Google Scholar]
  • 25.Yang P, Zhang Y, Ding HW, Liu J, Ye LQ, Xiao J, et al. Pedicle screw fixation with kyphoplasty decreases the fracture risk of the treated and adjacent non-treated vertebral bodies: a finite element analysis. J Huazhong Univ Sci Technolog Med Sci. (2016) 36(6):887–94. 10.1007/s11596-016-1680-x [DOI] [PubMed] [Google Scholar]
  • 26.Wang B, Zhan Y, Bai Y, Kong L, Li L, Zhang H, et al. Biomechanical analysis of a novel bone cement bridging screw system for the treatment of Kummell disease: a finite element analysis. Am J Transl Res. (2022) 14(10):7052–62. PMID: [PMC free article] [PubMed] [Google Scholar]
  • 27.Xu H, Feng Q, Ma X, Lan J, Ji J, Zhang Z, et al. Biomechanical behaviour of a novel bone cement screw in the minimally invasive treatment of Kummell’s disease: a finite element study. BMC Musculoskelet Disord. (2023) 24(1):967. 10.1186/s12891-023-07090-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.He D, Yu W, Chen Z, Li L, Zhu K, Fan S. Pathogenesis of the intravertebral vacuum of Kümmell’s disease (review). Exp Ther Med. (2016) 12(2):879–82. 10.3892/etm.2016.3369 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Young WF, Brown D, Kendler A, Clements D. Delayed post-traumatic osteonecrosis of a vertebral body (Kummell’s disease). Acta Orthop Belg. (2002) 68(1):13–9. PMID: [PubMed] [Google Scholar]
  • 30.Chen JB, Xiao YP, Chen D, Chang JZ, Li T. Clinical observation of two bone cement distribution modes of percutaneous vertebroplasty in the treatment of thoracolumbar Kümmell’s disease. J Orthop Surg Res. (2020) 15(1):250. 10.1186/s13018-020-01774-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Huang Y, Peng M, He S, Tang X, Dai M, Tang C. Clinical efficacy of percutaneous kyphoplasty at the hyperextension position for the treatment of osteoporotic Kümmell disease. Clin Spine Surg. (2016) 29(4):161–6. 10.1097/BSD.0000000000000259 [DOI] [PubMed] [Google Scholar]
  • 32.Chin DK, Park JY, Yoon YS, Kuh SU, Jin BH, Kim KS, et al. Prevalence of osteoporosis in patients requiring spine surgery: incidence and significance of osteoporosis in spine disease. Osteoporos Int. (2007) 18(9):1219–24. 10.1007/s00198-007-0370-8 [DOI] [PubMed] [Google Scholar]
  • 33.Chen T, Chu G, Qu Y, Wang Y, Lin C, Hu N, et al. Risk factor analysis of refracture in the same cemented vertebra after percutaneous kyphoplasty for Kümmell’s disease. J Neurosurg Spine. (2024) 40(2):255–64. 10.3171/2023.8.SPINE23498 [DOI] [PubMed] [Google Scholar]
  • 34.Kim KH, Kuh SU, Park JY, Kim KS, Chin DK, Cho YE. What is the importance of “halo” phenomenon around bone cement following vertebral augmentation for osteoporotic compression fracture? Osteoporos Int. (2012) 23(10):2559–65. 10.1007/s00198-012-1896-y [DOI] [PubMed] [Google Scholar]
  • 35.Guo J, Bai Y, Li L, Wang J, Wang Y, Hao D, et al. A comparative study of 2 techniques to avoid bone cement loosening and displacement after percutaneous vertebroplasty treating unstable Kummell disease. Neurospine. (2024) 21(2):575–87. 10.14245/ns.2347274.637 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Qin R, Zhang X, Liu H, Zhou B, Zhou P, Hu C. Application of anchoring technique in unilateral percutaneous vertebroplasty for neurologically intact Kümmell’s disease. Pain Res Manag. (2020) 2020:4145096. 10.1155/2020/4145096 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Wu H, Dai X, Liu H, Yang X, Liu S, Xu S, et al. Clinical and radiographical analysis of percutaneous kyphoplasty with multi-point cement anchoring technique for preventing bone cement displacement in Kümmell’s disease of stage I and II. Front Endocrinol. (2025) 16:1538337. 10.3389/fendo.2025.1538337 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Hoppe S, Loosli Y, Baumgartner D, Heini P, Benneker L. Influence of screw augmentation in posterior dynamic and rigid stabilization systems in osteoporotic lumbar vertebrae: a biomechanical cadaveric study. Spine. (2014) 39(6):E384–9. 10.1097/BRS.0000000000000198 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.


Articles from Frontiers in Rehabilitation Sciences are provided here courtesy of Frontiers Media SA

RESOURCES