Abstract
Diffusion exchange spectroscopy (DEXSY) is a method to probe exchange between domains of varying confinement. Analyses of DEXSY signals typically assume Gaussian diffusion within distinct compartments and first-order exchange kinetics between them. Other situations can yield DEXSY signal contrast with respect to mixing time, however, leading to potentially erroneous interpretation. Here, we demonstrate that a one-dimensional compartment with reflecting boundaries and without relaxation can by itself produce such contrast in certain experimental regimes. The origin of this contrast is the diffusive mixing of spin isochromats initially near versus far from either boundary, as the former can be relatively coherent in an effect known as edge enhancement or signal localization. We consider DEXSY signals in the case of extended field gradients and identical encodings. Signals were generated via a numerical approach that solves the Bloch-Torrey equation in discrete space and time using matrix operators. We find that in the localization regime, an apparent first-order rate constant of exchange, , can be extracted from DEXSY signals even in this minimal system. The measured is approximately proportional to , where is the diffusivity and is the domain size. Typically, . We attribute this localization-driven exchange to the relaxation of spatial magnetization modes with mixing time, noting that is the first non-zero eigenvalue of the Laplacian basis. These results demonstrate that DEXSY and related methods such as filter exchange spectroscopy (FEXSY) may not be specific to genuine barrier permeation.
Keywords: diffusion exchange spectroscopy (DEXSY), filter exchange spectroscopy (FEXSY), localization regime, matrix formalism
1. Introduction
Multidimensional NMR methods are a powerful means to characterize heterogeneity and compartmentalization in porous media [1–3]. Among them is diffusion exchange spectroscopy (DEXSY) [4,5]. DEXSY and related methods [3,6–14] probe exchange or more generally signal transfer between domains of distinct molecular mobility. These methods have been applied to study neural tissue [8, 12, 15–19], with the interpretation that they are measuring, or at least are sensitive to, a transmembrane exchange process.
However, the interpretation of DEXSY contrast as evidence of transmembrane exchange relies on several assumptions. The canonical framework assumes separated compartments with distinct diffusion coefficients (i.e., compartments exhibiting Gaussian diffusion) that are connected by first-order exchange kinetics (see also the Kärger model [20,21] and its extensions [22, 23]). While this may be an accurate modeling framework in the specific case of barrier-limited exchange between intracellular compartment(s) and relatively free extracellular space, other situations may also lead to DEXSY contrast.
Consider that central nervous system tissue, gray matter in particular, is characterized by ramified structures that span a broad continuum of length scales [24]. Recent theoretical and numerical studies [25–27] suggest that ramification alone, i.e., without membrane permeability, can generate exchange-like signatures in experiments similar to DEXSY. This should not be surprising, as the branches of a cellular process constitute domains of varying mobility along the gradient direction just as much as intra- and extracellular space(s).
These findings cast doubt on the specificity of DEXSY and related methods to transmembrane exchange. They also raise an adjacent question: to what extent can restricted diffusion and signal localization generate apparent exchange contrast? It has long been known that in certain experimental regimes, namely strong gradients, the signal profile arising in a restricted domain exhibits “edge enhancement,” [28–32] meaning signal near boundaries is more coherent. The theoretical basis for this effect was studied by several authors [33–39], and the regime in which it emerges was termed the “localization regime” [36].
In this regime, the difference in mobility between molecules near versus far from barriers suffices to produce signal contrast in a diffusion NMR experiment. It follows that DEXSY in this regime may be sensitive to intra-compartment signal transfer. In this manuscript, we investigate whether DEXSY can detect apparent exchange in a single one-dimensional compartment. That is, in the absence of any other source of signal contrast: e.g., permeable barriers, geometric heterogeneity, and relaxation processes such as surface relaxation.
We find that, indeed, localization alone can yield DEXSY signal contrast. Further, an apparent first-order rate constant of exchange, , can be extracted. It has a typical value of , and more generally , where ~ denotes approximate proportionality, is the diffusivity, and is the compartment length. To understand the effect, consider that signal localization yields non-uniform magnetization profiles. This sensitizes DEXSY to the relaxation of spatial modes — i.e., the profile projected onto the Laplacian or diffusion operator eigenbasis. The eigenvalue spectrum then determines , with being typically consistent with the first non-zero eigenvalue, due to it having the slowest decay. Put another way, we find that DEXSY is conditionally sensitive to the spectrum of the diffusion operator. Therefore, DEXSY contrast does not necessarily imply inter-compartmental exchange or exchange between distinct geometric domains.
Let us be more specific about the physical system and NMR experiment. We consider compartment length , where , with reflecting boundary conditions. In general, a DEXSY experiment has two diffusion encoding blocks with gradients applied in the same direction. These are separated by a longitudinal storage period or mixing time, . We consider a realization of DEXSY in which the encoding blocks have equal duration , and the gradient amplitude is constant within the encoding, i.e., each is a constant gradient spin echo (CGSE) [40]. In terms of the pulsed gradient spin echo (PGSE) [41] nomenclature, the CGSE corresponds to pulse timings , meaning no separation between gradient lobes. More formally, we assume the effective gradient waveform:
| (1) |
Radiofrequency (RF) pulses are assumed to be instantaneous. A fit to the decay of the final echo amplitude at with respect to can yield . Note that this realization of DEXSY formed the basis of several prior experimental and theoretical studies [11–14, 18, 42, 43], and has been shown to be optimal for sensitivity to first-order, two-site exchange [14, 44].
To constrain the scope, we will ignore relaxation mechanisms (i.e., spin-spin , spin-lattice , and surface relaxation), and focus on diffusion. Note that these can be addressed to some degree via normalization, see ref. [12]. Throughout, we present DEXSY data generated via a numerical method described in the following section. In the Appendices, we consider other approaches to DEXSY data sampling and analysis: namely, the numerical inverse Laplace transform approach (i.e., how DEXSY was originally conceived [4, 5]) and filter exchange spectroscopy (FEXSY), [6], sometimes called filter exchange imaging (FEXI) [7, 8]. Importantly, we show that our results also apply to FEXSY and its estimation of a time-dependent apparent diffusion coefficient (ADC). To our knowledge, this is the first investigation of localization effects in the context of DEXSY or indeed double diffusion encoding in general.
2. Signal generation and fitting approach
In this section, we describe our approach to generate DEXSY signals and extract . To generate signals, we expand upon the state transition matrix framework described in refs. [45, 46] by interleaving diffusion and gradient-induced phase evolution steps. Conceptually, our approach is similar to that of Callaghan [47], in that the signal is approximated as a matrix operator product (see also refs. [48, 49] and the multiple correlation function framework of Grebenkov [50, 51]; cf. ref. [52]). In contrast, however, we do not project the magnetization onto the Laplacian eigenbasis, instead evolving it directly on the spatial grid. Similar approaches date to Zientara and Freed [53], with later developments by Blees [54] and others [55, 56].
Consider the initial CGSE encoding. Let the domain be discretized into bins of width . Given an initial vector , i.e., the magnetization at in each bin, the diffusion process with reflecting or Neumann boundary conditions over a time step can be modeled by , where is the tri-diagonal matrix
| (2) |
and is the probability of moving to an adjacent bin. Note that the first and last elements of the main diagonal in capture the boundary conditions at the pore walls. To reproduce the Brownian mean-squared-displacement in the bulk (i.e., away from boundaries), one has that , and thus
| (3) |
Throughout, we will assume a uniform initial distribution such that the entries of are identical, reflecting the effect of the initial RF excitation.
For a linear gradient along with waveform , the phase evolution over the interval is roughly captured by the factor , where
| (4) |
is the incremental phase wavevector, and is the gyromagnetic ratio. That is, we can approximate the waveform as piece-wise constant over the interval. Let be an even multiple of . The magnetization vector at the end of the first CGSE encoding can be approximated as
| (5) |
where
| (6) |
is an diagonal matrix that captures phase evolution, is the Kronecker delta, , and denotes the midpoint of the jth bin.
The approximation is valid when displacement per interval is small such that phase evolution may be applied at (intermittent) static positions, i.e., dephasing and diffusion occur in sequence, similar to the narrow pulse approximation [30]. In practice, this requires and/or to be small compared to the dephasing length [36], or the travel distance to accrue radians of phase. The accuracy of each time step could be improved by combining the steps on the half interval and replacing with a Crank-Nicolson procedure [57], as described by Sen et al. [56], though we will show that we can attain sufficient accuracy as written.
It follows that the magnetization at the end of the DEXSY experiment (see Eq. (1)) is approximately
| (7) |
assuming is a multiple of , and noting there is no gradient during and that the second encoding has identical waveform to the first. This is convenient as long mixing times can be calculated by raising a sparse matrix to some power. Finally, the ensemble DEXSY signal, which we will express solely as a function of , is obtained by averaging over all bins,
| (8) |
where denotes the transpose and the modulus. Note that is generally purely real.
An apparent exchange rate, , can then be extracted from a phenomenological three-parameter fit of :
| (9) |
where corresponds to the total signal variation w.r.t. , and is a signal floor extrapolated to . This fit assumes that the variation in is due to a first-order rate process that is able to completely dephase the magnetization that undergoes said process. This would be true with barrier-limited exchange and encodings that have strong enough diffusion weighting to dephase any external magnetization. We will show, however, that this fit can also be applied to the system here, yielding in the absence of such a process.
To conclude this section, we discuss our approach to signal generation more broadly, addressing its formal interpretation and computational cost. Consider that Eq. (5) is in essence a discrete solution of the Bloch-Torrey equation:
| (10) |
Briefly, let and denote the diffusion and phase operators in continuous space. If we can take to be piecewise constant, say on the interval , then the evolution is
| (11) |
The Lie–Trotter product formula [58] states that given linear operators, here , one has that:
| (12) |
meaning that the operators can be applied sequentially over a sufficiently small time step . Our approach corresponds to this splitting, with and representing approximations of and in discrete space, respectively. To be more precise about , it is from the Taylor expansion
| (13) |
where is the identity matrix, and is a discrete space, first-order finite difference approximation of ; i.e., is tri-diagonal with the standard three-point stencil in the bulk of , and with the first and last elements of the main diagonal being −1 to satisfy the boundary condition. Thus, is understood to be equivalent to — see again Eq. (2) — and the update rule
| (14) |
is now understood to be a first-order (with regards to diffusion), Lie-Trotter splitting of the Bloch–Torrey evolution, expressed in a Markov chain or state transition sense. See refs. [53, 54, 56] for earlier implementations of the same general idea.
An advantage compared to Callaghan’s matrix formalism [47] is that one avoids Gibbs phenomena (i.e., ringing) due to mode truncation. Regarding computational cost, we note again that is sparse such that the number of operations scales as to a constant factor, where is the number of time intervals. This may be compared to for the matrix formalism, where is the number of modes. This suggests comparable cost when . It should be noted, though, that may be comparatively small for the matrix formalism, while our approach is constrained by , or equivalently . Cost aside, one effectively trades off issues of mode truncation for those of space discretization; we believe the latter are generally easier to assess.
Lastly, we note that the approach is readily extended to other experiments and systems. Arbitrary gradient waveforms can of course be approximated as piecewise constant. Different or additional boundary conditions and higher dimensions may be incorporated by adjusting the entries of . See the discussion for further details.
3. Numerical results
3.1. Magnetization profiles
Before looking at more general trends, let us first generate example magnetization profiles to visualize localization and its evolution due to mixing time. In Fig. 1a, the magnitude generated from Eq. (5) is plotted for parameters , , varying , with of the proton. To discretize, and , yielding from Eq. (3). Here it is convenient to introduce the notion of characteristic lengthscales. These are the dephasing length, , structural length, , and diffusion length, , i.e., the root-mean-square displacement per (effective) gradient application, . The localization regime emerges when , is the smallest lengthscale. For the parameters above, we have that , and for the chosen values of . Thus, we expect localization in these profiles, as . Note too that this satisfies , which is important for the validity of Eq. (5), along with being considerably smaller than 0.5.
Figure 1:
Absolute magnetization vectors plotted vs. bin midpoints (solid lines). Parameters were , , , with varying (light green to dark blue, respectively), and . Discretization was , and . Initial condition was . For , MC simulated data is included for comparison, plotted at every other bin (circles). See main text for parameters. (a) Magnetization for the first CGSE encoding block. (b) Magnetization after the second CGSE encoding block, with . (c – d) Keeping the same y-axis range as (b), magnetization with between encodings, respectively.
For , we have included results from Monte Carlo (MC) simulations to validate our approach to signal generation. Simulations were run with the same space discretization, , and 3 × 105 walkers. The step size was . To obtain a profile, a simulation was run for walkers initiated at the center of each bin, . Each bin was run once. Excellent agreement is observed up to simulation noise, and we proceed with confidence in the accuracy of the signal generation, again given that and . The signal generation was also run with doubled time and space resolution (data not shown) to verify convergence; no meaningful difference was observed.
Note that MC results are plotted versus initial bin position. The generated signal, on the other hand, is in effect plotted vs. final position. Swapping initial and final position is equivalent to a time reversal of the encoding, which in turn is equivalent to reversing the waveform, or . As the diffusion operator is real, and the gradient acts via an imaginary phase factor, the two quantities are in fact complex conjugates with identical magnitude that may be compared directly.
In Fig. 1a, one sees that localization is not just a phenomenon associated with strong signal dephasing. Even with relatively weaker gradient amplitudes such as , for which , there is a profile with less dephasing near the boundaries (recall that we initialized with ). In Fig. 1b, the second CGSE encoding block is included, and is plotted for the same parameters, with . This of course further dephases the magnetization. In addition, it homogenizes the profiles due to the added time and thereby diffusive mixing. This can be seen by comparing the depth of the profiles (from edge to center) — in Fig. 1a, the depth is ≈ 0.2, but is closer to ≈ 0.1 in Fig. 1b.
Following this reasoning, increasing should homogenize the profile further and decrease the overall magnetization as a result. In Fig. 1c, is shown for , other parameters kept the same. In Fig 1d, that is increased to . Note that the y-axis is kept the same for Figs. 1b – d to aid comparison. One sees that the profiles are decreased and somewhat more homogeneous, but not uniform. This is because the second encoding can reintroduce signal localization even if is large enough to induce complete mixing — meaning that at , the magnetization is equilibrated, or nearly uniform. We revisit this notion of equilibration time later, when discussing . Equilibration followed by renewed localization is why Fig. 1d appears to have similar or even slightly less homogeneous profiles than Fig. 1c.
3.2. DEXSY signal fits
From the trend in Figs. 1b – d, it is clear that the average magnetization for these parameters will decay such that can be measured. In Fig. 2, are plotted for and 30 values of log-linearly spaced from 10−1 – 102.5 ms, rounded to the nearest multiple of . Other parameters were kept the same as Fig. 1. Eq. (9) was then fit to the data, yielding (this can also be thought of as an apparent exchange time, , and . While the total signal variation is relatively modest, it remains clear that the interaction between localization and mixing time can produce DEXSY signal contrast that appears to be consistent with first-order exchange kinetics. In other words, the decay is roughly monoexponential. The fit is good with a root-mean-square error of ≈ 1.0 × 10−6, though we note some systematic bias remains (see inset of Fig. 2), indicating that this is not exactly a first-order process.
Figure 2:

DEXSY signal for the same parameters as in Fig. 1, but just . Signals (circles) were generated for 30 values of log-linearly spaced from 10−1 – 102.5 ms, rounded to the nearest multiple of . A fit of Eq. (9) is shown (dashed line), yielding , , and , with root-mean-square error ≈ 1.0 × 10−6. The inset shows early decay behavior for up to 10 ms with log scaling on the x-axis.
We next seek the behavior in various regimes. Specifically, in terms of the characteristic length scales , , and , in what regimes does the DEXSY signal from this system exhibit such contrast with ? Further, what is the degree of contrast (i.e., ), and what, if any dependencies does exhibit?
To address the first question, signals were simulated for and linearly spaced by , from up to and , respectively. Parameters , , and were kept the same as before. That is, we set and . Values of were also kept the same as Fig. 2. The resulting values from fits of Eq. (9) are shown in Fig. 3a. It can be seen that detectable values of — which we consider somewhat arbitrarily to be , i.e., requiring a signal-to-noise ratio ≳ 50 — appear in a narrow, banded region corresponding to and also .
Figure 3:
Fits of Eq. (9) for signals generated at , linearly spaced by , fixing , , , and . The values were the same as in Fig. 2. (a) Total signal variation, . Detectable signal variation, or , appears in a band lying between the lines and (dashed white lines), up to about . (b) Corresponding values of with the same axes as part (a), filtered for . Values are highly uniform ≈ 50 s−1, see color bar. (c) Values of , focusing only on the region of interest with finer resolution. The lengthscales were spaced by . Again, values shown are filtered by . Note the change in axes range and color scale.
The region can be framed in terms of the characteristic regimes described by Hürlimann et al [36]. When , is the smallest lengthscale, corresponding to the upper-left of Fig. 3a, diffusion is nearly free and there is little localization (i.e., the phase distribution is approximately Gaussian). When , or the upper-right of Fig. 3a, the motional averaging regime emerges where the phase is again approximately Gaussian, but this time via a central limit theorem argument [36,59]. Lastly, note that the diffusion-weighting b-value for the CGSE [40, 41, 60], given by , is equivalently expressed as
| (15) |
Thus, when the ratio , or the bottom part of Fig. 3a, one has that and the signal should be nearly fully dephased such that any contrast with would be difficult to detect, even if there were strong localization. This leaves just the described region. See also figure 2 in ref. [36] and figure 1 in ref. [56] for analogous non-dimensional plots. Note that according to these works, the region identified here would be intermediate, i.e., lying between characteristic regimes. This is because what is usually considered to be the localization regime is strongly dephased, whereas here we also take into account the visibility of exchange contrast, .
In Fig. 3b, the corresponding values of from Fig. 3a are plotted on the same axes, filtering for . One sees that the values of are highly homogeneous (see the color bar), and are all ≈ 50 s−1. This is a preliminary indication that due to localization has weak dependence on and , which were the parameters varied to generate the fits. The resolution is coarse, however, and there appears to be a trend of increasing toward smaller ratios that is worth investigating.
In Fig. 3c, the region of interest is looked at with finer resolution. Signals were generated for and spaced linearly by , from up to and , respectively, keeping other parameters the same. Values of are shown, again filtering for . Note the change in axes and color scale. One sees that the majority of the region is homogeneous with , but as both and become small increases to order ~ 100 s−1. Nonetheless, the statement that has weak dependence on and is broadly valid outside of this special case/region. Note that the fit in Fig. 2 corresponds to and , which lies near the bottom left of Fig. 3c, although the exact point is not shown. In that fit, we observed . We return to these results later and provide a physical explanation for the relative homogeneity of and the exception for small and .
3.3. Exchange rate dependencies
We next explore whether and how depends on and . Let us isolate an optimal set of lengthscales: and , which lies near the maximum shown in Fig. 3a. Signals were generated for linearly spaced by 0.1 from 0.5 – 3 μm2/ms and linearly spaced by 1 from 2 – 20 μm. Values of and were adjusted to keep the ratios specified above, with rounded to the nearest tenth of a millisecond. For discretization, , while was adjusted with to maintain , i.e., from Eq. (3), rounded to the nearest tenth of a micron. In Fig. 4a, the values from fits of Eq. (9) are shown on a log color scale. In Fig. 4b, cross-sections at fixed or are shown. The plot with is shown with log-log axes. These plots reveal approximate and proportionalities for such that becomes very large ≳ 103 s−1 in the upper left corner of Fig. 4a, where and .
Figure 4:

Fitted for fixed ratios of and , and spaced linearly by 1 from 2 – 20 μm and by 0.1 from 0.5 – 3 μm2/ms. Discretization was with adjusted to maintain . (a) Values of on a log color scale. Dashed lines indicate 1-D cross-sections shown in the next part. (b) 1-D cross sections of (a) at fixed (left) and (right). The plot vs. is on a log-log axis and the dependence is illustrated.
What is the origin of these proportionalities? Consider that any arbitrary can be represented in terms of the eigenmodes of the diffusion operator. For reflecting boundaries, these are cosine modes with (non-zero) eigenvalues:
| (16) |
As the equilibration process with is diffusive, the decay of these modes should proceed with rates . It then follows that , irrespective of the detailed decomposition of , will have approximate proportionality
| (17) |
Put simply, within the region highlighted in Fig. 3, DEXSY is sensitive to the relaxation of spatial magnetization modes that are established by the first CGSE.
Although this is not a first-order rate process in a physical sense, it can be approximately modeled as such when the first (non-zero) mode dominates. This is somewhat the case seen in Figs. 1 and 2 — the profile is roughly a (shifted and scaled) cosine of the form . We point out that for and , , in agreement with in the homogeneous regions of Figs. 3b – c. Thus we can refine the proportionality to an approximation in this region:
| (18) |
When higher modes are needed to represent , the signal decay should become multi-exponential, though the first mode should still dominate the longer behavior. Note that the slight biases seen in Fig. 2 at short times may reflect such higher mode contributions.
That being said, with this view in mind, the fact that has weak dependence on and is no longer surprising — these parameters affect only through their effect on the shape of and its resulting decomposition. If these shapes tend to be similar, then said effect is weak. This line of reasoning provides an avenue by which to explore the physical origin of the trend seen in Fig. 3c, where increases as the ratios and become small. That is, do the profiles with small ratios truly have more higher-mode content than those with larger ratios, resulting in larger ?
Let us show examples of eigen-decomposition of . Specifically, we consider the eigenvectors of the discrete, finite difference diffusion operator , and denote them as column vectors with eigenvalues . These should approximate the cosine modes consistent with the boundary problem in continuous space. The eigenvectors are taken to be orthonormal, i.e., . Then,
| (19) |
where the coefficients are given by projection of onto the eigenspace. The magnetization after (before the second encoding) can be approximated as
| (20) |
In this way, the rate of equilibration and thereby signal decay with is tied to the spectrum of .
In Fig 5a, profiles are shown for a fixed ratio of , while varying . All other parameters are kept the same as Fig. 3. Note that these values of , are chosen to move diagonally through the region-of-interest identified in Fig. 3, starting in the area with elevated (see Fig. 3c) and moving into the more homogeneous area when . In Fig. 5b, the absolute coefficients are shown up to mode . One sees that indeed the smallest has more higher mode content. See in particular the tails of the spectra. The corresponding values of (fits not shown), are , respectively.
Figure 5:

Examples of eigen-decomposition of . The ratio was fixed, while was varied (light to dark, respectively). (a) Absolute profiles . Note that fixing yields profiles with similar maxima as . (b) Absolute eigen-decomposition coefficients in the basis , plotted on a log y-axis. Note the difference in tails, with increasing high-frequency content as and decrease. The corresponding values of (fits not shown) are ≈ [310, 130, 53] s−1, in legend order.
One aspect of strong localization is that the persistent or more coherent boundary layer of signal scales in relative size as — see Stoller et al. [33]. Thus, as this ratio becomes small, a plateau in emerges in the center of the domain, as seen clearly in Fig. 5a. It is this plateaued shape that requires higher spatial frequencies represent, driving increased . When localization is weaker (or larger), the shape is roughly uniperiodic on the domain (see again Figs. 1 and 5a), hence there is less higher mode content as confirmed by Fig. 5b, and the decay of should be closer to monoexponential.
Though this spectral interpretation is elegant, we caution against trying to predict via (e.g., as a weighted average of ), as is observed only via a phenomenological fit. The fit may obfuscate the spectrum and blur any higher-frequency content. In other words, is a phenomenological projection of a multiexponential process. For now, we can say only that small and leads to larger , driven by spectral features of . It should also be noted that small ratios are difficult to achieve in practice, requiring large and short unless is extremely large. Consider that the values used in Fig. 5 are and , respectively, where the former and can be achieved at present only on stray field or static gradient hardware [61]. In the vast majority of experimental cases, one is likely to be in the homogeneous region where .
4. Discussion
4.1. Summary of findings
We have investigated whether a realization of DEXSY with identical CGSE encodings, characterized by gradient amplitude and encoding time , can yield apparent exchange contrast with respect to mixing time in a single, one-dimensional compartment of length with reflecting boundaries. To aid our investigation, we presented an approach to generate signals based on a first-order, Lie-Trotter splitting of the Bloch-Torrey evolution, which was then validated against MC simulations. Using this approach, we identified a parameter range or region in which apparent exchange can be detected, consistent with the localization regime. This serves as a minimal counterexample to the assertion that DEXSY is uniquely sensitive to exchange between distinct compartments or geometric domains.
In terms of the characteristic lengthscales and , this region can be described as . In most of this region, the associated rate constant , which is obtained via a phenomenological three-parameter fit, is approximately , and is more generally . This value is equivalent to the first non-zero eigenvalue of the diffusion operator. We interpret localization-driven exchange as being related to the relaxation of spatial magnetization modes established by the first CGSE with . When the ratios and are both small ≲ 0.2, it was noted that is increased. This is due to the profile at the first CGSE having a plateaued region in the center of the domain when said ratios are small, which requires higher modes to represent.
4.2. Implications in realistic samples
What do these results imply for DEXSY studies of realistic samples such as neural tissue? We first point out that the region is not atypical in terms of experimental and physical parameters. Recalling Eq. (15), it corresponds to and . This translates to whenever there is substantial signal decay and the domain is also larger than the typical root-mean-square displacement. Importantly, we note that the former condition is not constrained by gradient hardware per se, as it is the ratio that is relevant. In principle, any gradient amplitude can achieve large with sufficient encoding time , if relaxation permits.
Let us provide some concrete values. For and from 10 – 100 ms, encompassing typical encoding times in conventional scanners, one has . Given that soma have diameters that range from ~ 5 – 20 μm [24], one may encounter structures larger than in the study of biological tissue, particularly for short encodings. As somata comprise between ~ 10 – 40% of gray matter by volume [62–64], the possibility of localization effects in a fraction of neural tissue cannot be neglected. Of course, a similar assessment could be performed for other tissue types and components, or really any sample and/or parameter range, as the region is expressed non-dimensionally.
How exactly localization would impact the measurement of in biological samples is not obvious, however. Here we have considered a minimal system, isolating localization to yield a clean spectral result. A more realistic system would include relaxation mechanisms, higher dimensionality, a continuum of lengthscales, membrane permeability, geometric heterogeneity, etc. All of these factors may act in tandem to affect .
Some of these factors are not expected to affect the result. Uniform relaxation mechanisms, namely relaxation during and relaxation during the encodings, would scale all modes equally and would not affect the spectral interpretation of if properly normalized. Regarding higher dimensions, we point out that the eigenvalue scaling is conserved such that the core result of scaling with over the squared structural length is likewise conserved, though the prefactor(s) will depend on the geometry under consideration.
Other factors may affect the result. Surface relaxation, for instance, modifies the boundary condition from Neumann to Robin form, , where is the surface sink strength density [65]. This introduces another lengthscale, , which can be thought of as the distance over which diffusion can replenish magnetization lost at the surface. When , surface effects are weak and the results described here should hold. At intermediate values , surface relaxation may compete with gradient-induced localization, particularly when one has the ordering: . This may reduce spatial heterogeneity in the magnetization profile and thereby localization-driven contrast. Interestingly, we note that when (i.e., the “slow-diffusion” regime of Brownstein and Tarr [65]), surface relaxation may become strong enough to “invert” the magnetization profile, i.e., the profile may have a central peak [66] instead of a trough as seen here. In this case, intra-compartment exchange may proceed in a similar manner with , though via different spectra in an eigenbasis consistent with the Robin boundary conditions.
Geometric heterogeneity and/or membrane permeation may act in a similar way to surface relaxation. That is, they should both diminish the localization effect. In the former, consider that diffusion along an orthogonal branch provides a pathway by which localized signal can escape and dephase. Similarly for the latter, signal can escape through the barrier (e.g., see the magnetization profiles in figure 4 of ref. [67]). For branching domains, we speculate that the exchange processes should not interact, i.e., localized signal is just as likely to diffuse along a branch vs. non-localized signal. For permeation, however, there is an interaction as localization biases the signal to be near barriers. This may amplify the influence of permeability on signal evolution [67]. If is interpreted to be proportional to the surface-to-volume ratio (SVR) in the sense that in the barrier-limited case, where is permeability, localization may inflate the effective SVR and thus the measured for the barrier. In this way, from barrier permeation may depend on , which is an avenue of future study.
Another point to consider is heterogeneous lengthscales, i.e., if is distributed. Even if domains are non-communicating in that they cannot exchange magnetization, the that is observed will be influenced by all domains, arising from a complicated superposition of spectra. We point out that small domains will have much faster due to the scaling — e.g., for and , one has which would equilibrate over just a few milliseconds. Larger domains may dominate the longer- signal behavior and have more influence on the fit. We also note that the amount of contrast varies (see again Fig. 3a) with a maxima around , . This is another source of bias that emphasizes domains near this maxima for the given and . Thus, we suspect that the observable will be biased towards certain domains, rather than being proportionally weighted by volume or density. In addition, there may be heterogeneous and surface relaxivity, which can also produce exchange contrast [68–70].
In summary, even if localization-driven exchange is expected in terms of the characteristic lengthscales, the interpretation that may be complicated or even confounded by myriad factors: surface relaxivity, alternative exchange mechanisms, and lengthscale heterogeneity. The former two can decrease the localization effect. All of these may contribute to highly multiexponential behavior in the signal. Thus, the localization effect described here should be regarded as one possible source of DEXSY signal contrast, not necessarily as a dominant or even likely one. Note that the maximal contrast from this mechanism is ~ 0.1 (in terms of normalized signal, see again Fig. 3a) such that if there is greater contrast with , there are likely other processes in play. The only case in which the interpretation here is exact is when the sample is a closed pore or homogeneous collection of pores with non-relaxing boundaries. Again, the primary implication of this work is that DEXSY is not specific to membrane permeation.
4.3. Extensions and outlook
Including and accounting for the above effects is a natural extension. Including more reflecting boundaries (i.e., partitioning the domain) is trivial. Uniform relaxation mechanisms can be accounted for by interleaving an additional diagonal matrix operator with entries of the form . To include higher dimensions, one can add shifted diagonals to that represent motion along different spatial axes, while also flattening and extending the diagonal operator matrices — e.g., see ref. [46] for a two-dimensional implementation of . Even advective drift can be included by making asymmetric in accordance to an Eulerian specification of the flow field.
Regarding boundary conditions, a relaxing boundary can be modeled by modifying the first and last entries in from to [56]. As an extension, imagine a third non-dimensional axis in Fig. 3, along which we speculate that exchange contrast may vanish around , but persists with (potentially different) rates at both extremes, as discussed. Permeable barriers can be modeled by modifying the elements in adjacent to such a barrier from and to and , where represents a transition probability related to the physical permeability by [45, 46]. These boundary conditions can also be combined as the term is additive. The signal generation framework is thus highly flexible and can be adjusted to explore the speculations above, such as whether can surface relaxivity drive exchange contrast when , how exactly localization and barrier permeation interact, etc.
That said, let us consider the case where the interpretation holds — closed, non-relaxing pore(s). In this case, localization-driven exchange is not merely an artifact, but could serve as a means to estimate the pore size. Consider that large pores can be difficult to probe with conventional PGSE as the deviation from free diffusion may be small until the signal is strongly dephased, which may require long encodings leading to relaxation issues. The experiment here may be a preferable alternative as it uses a longitudinal storage period (typically, ). For a proof-of-principle on leveraging localization to estimate size, see ref. [71].
In a similar vein, the localization effect in the first CGSE can be seen as an excitation of higher eigenmodes which then relax during and are observed or read out during the second CGSE. There is potentially rich information contained in this signal behavior, which we only observe in a crude sense via a monoexponential fit. A more involved analysis approach such as a numerical inverse Laplace transform has the potential to reveal the excited spectrum as shown in Fig. 5b. This may be a useful way to probe high eigenmodes and thereby information about the shape of the domain [72]. Parallels may be drawn to methods such as diffusion pore imaging [73] and ref. [74] which uses inhomogeneous internal magnetic fields. We also show in Appendix B that the second CGSE which functions as a readout does not need to be identical to the first, broadening the design space of the method. Moreover, the first encoding may be designed to vary how it excites the spectrum. For instance, an oscillating gradient spin echo (OGSE) [75, 76] might excite high modes selectively.
Conclusion
Though DEXSY and related methods are commonly believed to be sensitive to barrier permeation, there is growing evidence that other phenomena can also produce exchange-like signal contrast. We detail one such phenomenon that was previously unstudied, in which signal localization sensitizes DEXSY to the relaxation of spatial magnetization modes. Clear criteria for when this phenomenon may be expected were provided in terms of non-dimensional lengthscale ratios. Additionally, we showed that for a reflecting, one-dimensional compartment, the observed exchange rate is typically consistent with the first non-zero eigenvalue of the Laplacian basis. Our results highlight the potential complexity of DEXSY and double diffusion encoding signals, even in seemingly simple systems.
Acknowledgments
TXC, NHW, and PJB were supported by the intramural research program (IRP) of the Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD). NHW was funded by the Military Traumatic Brain Injury Initiative (MTBI2) through the Uniformed Services University of the Health Sciences (USU), Bethesda, MD (award No. HU0001-24-2-0051).
Appendix A. Full DEXSY sampling with numerical inverse Laplace transform
In the main text, we considered only a realization of DEXSY in which the encodings are identical. There are a variety of ways to sample and analyze DEXSY data in the literature [77]. We consider two other approaches in these Appendices. In its original conception, DEXSY involves a numerical, two-dimensional inverse Laplace transform (ILT) [4], where the variables are the b-value in each encoding, denoted and . One assumes continuously distributed Gaussian compartments such that the signal is described by
| (A.1) |
where is the joint probability density function (PDF) of the diffusivities during each encoding, and . Off-diagonal content in the PDF as recovered by an ILT is thought to be indicative of exchange.
Signals were generated by the method in the main text with parameters , , , , , and . This gives and thus we expect to be in the region where — see again Fig. 3c. Values of in each encoding were chosen to yield a 40 × 40 b-value grid, uniformly and linearly spaced between 0 – 40 ms/μm2, i.e., ranges from 0 – 80.
For the ILT, we implemented a non-negative least squares optimization with regularization, detailed below. Let denote the signal kernel per encoding, with discrete form for the ith b-value and jth diffusivity, and we note that the b-values are uniform such that the same may be used for both encodings. We assume a grid of 60 values of log-linearly spaced between 10−3 – 101 μm2/ms. A solution for the discrete PDF, denoted , can be found by minimizing
| (A.2) |
where denotes the norm, is the signal on the b-value grid for some , and here denotes a regularization parameter. We take a gradient descent approach wherein is updated as
| (A.3) |
where is an update velocity set to . Also, is constrained at each update to be non-negative, with negative entries set to 0. Gaussian white noise was added to at an SNR of 100 prior to the ILT. The regularization parameter was set to based on a rough L-curve estimate [78] (data not shown). Lastly, was normalized to numerically integrate to 1.
In Fig. A.1b, a contour map of at (left-to-right) is shown, with the contours linearly spaced from 0 – 1 by 0.05. The value is about . Note that the signal decays very slowly with , considering that we go up to 40 ms/μm2 or . One can also see the signal contours develop curvature along the forward diagonal for which is constant. This is in line with previous work [11, 13, 79] that showed such curvature is indicative of an exchange process. In Fig. A.1b, the corresponding spectra, or PDFs are shown. There is a single, highly diffuse peak, that spreads orthogonally away from the equality line (dotted) as increases. The intrinsic diffusivity is also marked by a cross for comparison.
Figure A.1:
Signals and spectra from numerical ILT. Signals were generated with , , , , , and , with varied to produce a uniform grid of 40 × 40 b-values linearly spaced from 0 – 40 ms/μm2. Three values of were considered (left-to-right). (a) Contour maps of the signal, with isolines linearly spaced from 0 – 1 by 0.05. Note the off-diagonal curvature as increases. (b) Corresponding spectra from a regularized, non-negative least squares implementation of the ILT, shown with a log color scale. These are normalized to numerically integrate to 1. For discretization, 60 values of , were used, log-linearly spaced between 10−3 – 101 μm2/ms. Gaussian noise was added to the signal at an SNR of 100 before the ILT. The line is shown (dotted), as is the intrinsic diffusivity (cross). Note the single, diffuse peak and its spreading behavior orthogonal to as increases.
Localization-driven exchange does not manifest as separated spectral peaks. This is because the signal kernel fails to describe non-Gaussian signal decay. Decay in the localization regime is, to a first approximation, described instead by [33, 39]. The diffuse peak seen in Fig. A. 1 can be seen as the ILT attempting to approximate a stretched exponential shape using many exponentials, which leads to a broad diffusivity spectrum. See also figure 2 in ref. [13] for a similar study of diffusion-diffusion spectra under non-Gaussian signal decay. Thus, the ILT approach is misleading in the presence of localization, as it yields a broad spectrum to describe what is actually a single compartment.
Still, it remains true that localization-driven exchange results in greater off-diagonal content in the spectrum (i.e., away from ). The precise way in which the spectrum spreads — orthogonally from , or equivalently along the axis — can be thought of as follows. Consider the variance in the (spectral) diffusivity difference :
| (A.4) |
The covariance term will decrease with irrespective of the particular or true representation of the signal, simply because the encodings are increasingly decorrelated via time separation. Thus, the variance along the axis is expected to increase, and this is what is seen in Fig. A.1b from left to right.
Appendix B. Filter exchange spectroscopy (FEXSY)
FEXSY or FEXI is another approach which views exchange as a recovery process in the ADC. Using the nomenclature of the previous appendix, FEXSY applies a fixed “filter” of , usually denoted [6], after which is varied to measure an ADC, which we denote as . As a minimal example, at a given ,
| (B.1) |
where and denote two b-values in the second encoding. One then observes the recovery of to extract :
| (B.2) |
where is and is an apparent intrinsic diffusivity, not necessarily equal to . Although this is written in terms of ADC values, it is functionally identical to Eq. (9) in the sense that one has a limiting value (vs. ), a total variation (vs. ), and an exponential rate constant .
In fact, the experiment in the main text can be viewed as a special case of FEXSY where or and , wherein instead of extracting an ADC, we leave the fit in terms of the raw signal — see again Eqs. (B.1) – (B.2) above and compare to Eq. (9). Note that Eq. (B.1) can also be thought as a finite difference derivative approximation of the log signal, , which preserves the exponential term if we substitute in the form of Eq. (9). This means that we can expect to measure the same as in the main text when the b-values are chosen accordingly. As a corollary, FEXSY should be sensitive to localization when the filtering encoding is in the described regime of .
That said, we can use this appendix to explore here whether the result holds for , as FEXSY makes no explicit prescription for the choice of values. One might, for example, want to use small to preserve signal if or is large. We keep the parameters used in the previous appendix, varying only in each encoding. We choose , corresponding to , , and again . Looking at Fig. 3c, we again expect to be in the homogeneous region of for these parameters. For , we choose ≈ [0.13, 0.52] ms/μm2 to measure , corresponding to , respectively. For , we keep the same sampling as in Fig. 2, with 30 values of log-linearly spaced from 10−1 – 102.5 ms.
In Fig. B.2a, the raw signals are plotted for the two values of . Fits of Eq. (9) are also shown, and both yield , consistent with , as expected. In Fig. B.2b, the corresponding estimates are shown, calculated using Eq. (B.1). The same fit was used, which yields a similar . These results suggest that the second CGSE is not relevant to the behavior with , as the same rate is measured at various . Thus, we expect that arbitrary readout encodings may be used to probe the same phenomenon. In addition, one sees that interpreting the data in terms of preserves the time-dependence, as confirmed by the similar . This step can be considered ancillary if the goal is to measure , though and themselves may also be parameters of interest. To conclude, we have verified that our findings in the main text apply to FEXSY. Any encoding consistent with the regime identified should sensitize FEXSY to localization-driven exchange and thereby the diffusion spectrum.
Figure B.2:

Signals and for an example FEXSY experiment. Signal generation parameters were the same as Fig. A.1, and were the same as Fig. 2. The filter corresponds to , while correspond to (light green and dark blue, respectively). (a) Raw signals . A fit of Eq. (9) is also shown (dashed line), yielding in both cases. (b) Corresponding calculated by Eq. (B.1). A fit of Eq. (9) yields a similar . Note that since this is a recovery process, in the fit is negative.
Footnotes
Declaration
The authors declare no competing financial interests.
The views, information or content, and conclusions presented do not necessarily represent the official position or policy of, nor should any official endorsement be inferred on the part of, the Uniformed Services University, the Department of War, the U.S. Government, or The Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc. The contributions of the NIH author(s) are considered Works of the United States Government. The findings and conclusions presented in this paper are those of the author(s) and do not necessarily reflect the views of the NIH or the U.S. Department of Health and Human Services.
Data availability
The MATLAB code and simulated or generated data are available upon reasonable request.
References
- [1].Benjamini D., Basser P. J., Multidimensional correlation mri, NMR in Biomedicine 33 (12) (2020). doi: 10.1002/nbm.4226. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [2].Topgaard D., Multidimensional diffusion mri, Journal of Magnetic Resonance 275 (2017) 98–113. doi: 10.1016/j.jmr.2016.12.007. [DOI] [PubMed] [Google Scholar]
- [3].Henriques R. N., Palombo M., Jespersen S. N., Shemesh N., Lundell H., Ianus A. ¸, Double diffusion encoding and applications for biomedical imaging, Journal of Neuroscience Methods 348 (2021) 108989. doi: 10.1016/j.jneumeth.2020.108989. [DOI] [PubMed] [Google Scholar]
- [4].Callaghan P. T., Furó I., Diffusion-diffusion correlation and exchange as a signature for local order and dynamics, The Journal of Chemical Physics 120 (8) (2004) 4032–4038. doi: 10.1063/1.1642604. [DOI] [PubMed] [Google Scholar]
- [5].Qiao Y., Galvosas P., Adalsteinsson T., Schönhoff M., Callaghan P. T., Diffusion exchange nmr spectroscopic study of dextran exchange through polyelectrolyte multilayer capsules, The Journal of Chemical Physics 122 (21) (2005). doi: 10.1063/1.1924707. [DOI] [PubMed] [Google Scholar]
- [6].Åslund I., Nowacka A., Nilsson M., Topgaard D., Filter-exchange PGSE NMR determination of cell membrane permeability, Journal of Magnetic Resonance 200 (2) (2009) 291–295. [DOI] [PubMed] [Google Scholar]
- [7].Lasič S., Nilsson M., Lätt J., Ståhlberg F., Topgaard D., Apparent exchange rate mapping with diffusion mri, Magnetic Resonance in Medicine 66 (2) (2011) 356–365. doi: 10.1002/mrm.22782. [DOI] [PubMed] [Google Scholar]
- [8].Nilsson M., Lätt J., van Westen D., Brockstedt S., Lasič S., Ståhlberg F., Topgaard D., Noninvasive mapping of water diffusional exchange in the human brain using filter-exchange imaging, Magnetic Resonance in Medicine 69 (6) (2013) 1572–1580. [DOI] [PubMed] [Google Scholar]
- [9].Lampinen B., Szczepankiewicz F., van Westen D., Englund E., C Sundgren P., Lätt J., Ståhlberg F., Nilsson M., Optimal experimental design for filter exchange imaging: Apparent exchange rate measurements in the healthy brain and in intracranial tumors, Magnetic Resonance in Medicine 77 (3) (2016) 1104–1114. doi: 10.1002/mrm.26195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [10].Benjamini D., Komlosh M. E., Basser P. J., Imaging local diffusive dynamics using diffusion exchange spectroscopy mri, Physical Review Letters 118 (15) (2017). doi: 10.1103/physrevlett.118.158003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [11].Cai T. X., Benjamini D., Komlosh M. E., Basser P. J., Williamson N. H., Rapid detection of the presence of diffusion exchange, Journal of Magnetic Resonance 297 (2018) 17–22. doi: 10.1016/j.jmr.2018.10.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [12].Williamson N. H., Ravin R., Cai T. X., Benjamini D., Falgairolle M., O’Donovan M. J., Basser P. J., Real-time measurement of diffusion exchange rate in biological tissue, Journal of Magnetic Resonance 317 (2020) 106782. doi: 10.1016/j.jmr.2020.106782. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [13].Cai T. X., Williamson N. H., Ravin R., Basser P. J., Disentangling the effects of restriction and exchange with diffusion exchange spectroscopy, Frontiers in Physics 10 (2022) 805793. doi: 10.3389/fphy.2022.805793. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [14].Cai T. X., Williamson N. H., Ravin R., Basser P. J., The diffusion exchange ratio (dexr): A minimal sampling of diffusion exchange spectroscopy to probe exchange, restriction, and time-dependence, Journal of Magnetic Resonance 366 (2024) 107745. doi: 10.1016/j.jmr.2024.107745. [DOI] [PubMed] [Google Scholar]
- [15].Ramadan S., Diffusion-exchange weighted imaging, Magnetic Resonance Insights 3 (2009). doi: 10.4137/mri.s3504. [DOI] [Google Scholar]
- [16].Bai R., Li Z., Sun C., Hsu Y.-C., Liang H., Basser P., Feasibility of filter-exchange imaging (fexi) in measuring different exchange processes in human brain, NeuroImage 219 (2020) 117039. doi: 10.1016/j.neuroimage.2020.117039. [DOI] [PubMed] [Google Scholar]
- [17].Breen-Norris J. O., Siow B., Walsh C., Hipwell B., Hill I., Roberts T., Hall M. G., Lythgoe M. F., Ianus A., Alexander D. C., Walker-Samuel S., Measuring diffusion exchange across the cell membrane with dexsy (diffusion exchange spectroscopy), Magnetic Resonance in Medicine 84 (3) (2020) 1543–1551. doi: 10.1002/mrm.28207. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [18].Williamson N. H., Ravin R., Cai T. X., Falgairolle M., O’Donovan M. J., Basser P. J., Water exchange rates measure active transport and homeostasis in neural tissue, PNAS Nexus 2 (3) (2023) pgad056. doi: 10.1093/pnasnexus/pgad056. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [19].Li Z., Liang C., He Q., Feiweier T., Hsu Y., Li J., Bai R., Comparison of water exchange measurements between filter-exchange imaging and diffusion time-dependent kurtosis imaging in the human brain, Magnetic Resonance in Medicine 93 (6) (2025) 2357–2369. doi: 10.1002/mrm.30454. [DOI] [PubMed] [Google Scholar]
- [20].Kärger J., Zur bestimmung der diffusion in einem zweibereichsystem mit hilfe von gepulsten feldgradienten, Annalen der Physik 479 (1–2) (1969) 1–4. doi: 10.1002/andp.19694790102. [DOI] [Google Scholar]
- [21].Kärger J., Nmr self-diffusion studies in heterogeneous systems, Advances in Colloid and Interface Science 23 (1985) 129–148. doi: 10.1016/0001-8686(85)80018-x. [DOI] [Google Scholar]
- [22].Jelescu I. O., de Skowronski A., Geffroy F., Palombo M., Novikov D. S., Neurite exchange imaging (nexi): A minimal model of diffusion in gray matter with inter-compartment water exchange, NeuroImage 256 (2022) 119277. doi: 10.1016/j.neuroimage.2022.119277. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [23].Jensen J. H., Diffusional kurtosis time dependence and the water exchange rate for the multi-compartment kärger model, Magnetic Resonance in Medicine 91 (3) (2023) 1122–1135. doi: 10.1002/mrm.29926. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [24].Aird-Rossiter C., Zhang H., Alexander D. C., Jones D. K., Palombo M., Decoding gray matter, large-scale analysis of brain cell morphometry to inform microstructural modeling of diffusion mr signals, Communications Biology 9 (1) (2026). doi: 10.1038/s42003-025-09353-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [25].Khateri M., Reisert M., Sierra A., Tohka J., Kiselev V. G., What does fexi measure?, NMR in Biomedicine 35 (12) (2022). doi: 10.1002/nbm.4804. [DOI] [PubMed] [Google Scholar]
- [26].Chakwizira A., imşek K. S, Szczepankiewicz F., Palombo M., Nilsson M., The role of dendritic spines in water exchange measurements with diffusion mri: Double diffusion encoding and free-waveform mri (2025). doi: 10.48550/ARXIV.2504.21537. [DOI] [PubMed] [Google Scholar]
- [27].Kiselev V. G., Li J.-R., What does fexi measure in neurons? (2026). doi: 10.48550/ARXIV.2601.20657. [DOI] [Google Scholar]
- [28].Hyslop W. B., Lauterbur P. C., Effects of restricted diffusion on microscopic nmr imaging, Journal of Magnetic Resonance 94 (3) (1991) 501–510. doi: 10.1016/0022-2364(91)90136-h. [DOI] [Google Scholar]
- [29].Pütz B., Barsky D., Schulten K., Edge enhancement by diffusion in microscopic magnetic resonance imaging, Journal of Magnetic Resonance 97 (1) (1992) 27–53. doi: 10.1016/0022-2364(92)90235-y. [DOI] [Google Scholar]
- [30].Callaghan P., Coy A., Forde L., Rofe C., Diffusive relaxation and edge enhancement in nmr microscopy, Journal of Magnetic Resonance, Series A 101 (3) (1993) 347–350. doi: 10.1006/jmra.1993.1057. [DOI] [Google Scholar]
- [31].Stepišnik J., Duh A., Mohorič A., Serša I., Mri edge enhancement as a diffusive discord of spin phase structure, Journal of Magnetic Resonance 137 (1) (1999) 154–160. doi: 10.1006/jmre.1998.1678. [DOI] [PubMed] [Google Scholar]
- [32].Özarslan E., Nevo U., Basser P. J., Anisotropy induced by macroscopic boundaries: Surface-normal mapping using diffusion-weighted imaging, Biophysical Journal 94 (7) (2008) 2809–2818. doi: 10.1529/biophysj.107.124081. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [33].Stoller S. D., Happer W., Dyson F. J., Transverse spin relaxation in inhomogeneous magnetic fields, Physical Review A 44 (11) (1991) 7459–7477. doi: 10.1103/physreva.44.7459. [DOI] [PubMed] [Google Scholar]
- [34].de Swiet T. M., Sen P. N., Decay of nuclear magnetization by bounded diffusion in a constant field gradient, The Journal of Chemical Physics 100 (8) (1994) 5597–5604. doi: 10.1063/1.467127. [DOI] [Google Scholar]
- [35].Deswiet T., Diffusive edge enhancement in imaging, Journal of Magnetic Resonance, Series B 109 (1) (1995) 12–18. doi: 10.1006/jmrb.1995.1141. [DOI] [Google Scholar]
- [36].Hürlimann M. D., Helmer K. G., de Swiet T. M., Sen P. N., Spin echoes in a constant gradient and in the presence of simple restriction, Journal of Magnetic Resonance, Series A 113 (1995) 260–264. doi: 10.1006/jmra.1995.1091. [DOI] [Google Scholar]
- [37].Frøhlich A. F., Østergaard L., Kiselev V. G., Effect of impermeable boundaries on diffusion-attenuated mr signal, Journal of Magnetic Resonance 179 (2) (2006) 223–233. doi: 10.1016/j.jmr.2005.12.005. [DOI] [PubMed] [Google Scholar]
- [38].Grebenkov D. S., Diffusion mri/nmr at high gradients: Challenges and perspectives, Microporous and Mesoporous Materials 269 (2018) 79–82. doi: 10.1016/j.micromeso.2017.02.002. [DOI] [Google Scholar]
- [39].Moutal N., Demberg K., Grebenkov D. S., Kuder T. A., Localization regime in diffusion nmr: Theory and experiments, Journal of Magnetic Resonance 305 (2019) 162–174. doi: 10.1016/j.jmr.2019.06.016. [DOI] [PubMed] [Google Scholar]
- [40].Carr H. Y., Purcell E. M., Effects of diffusion on free precession in nuclear magnetic resonance experiments, Physical Review 94 (3) (1954) 630–638. doi: 10.1103/physrev.94.630. [DOI] [Google Scholar]
- [41].Stejskal E. O., Tanner J. E., Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient, The Journal of Chemical Physics 42 (1) (1965) 288–292. doi: 10.1063/1.1695690. [DOI] [Google Scholar]
- [42].Williamson N. H., Ravin R., Benjamini D., Merkle H., Falgairolle M., O’Donovan M. J., Blivis D., Ide D., Cai T. X., Ghorashi N. S., Bai R., Basser P. J., Magnetic resonance measurements of cellular and sub-cellular membrane structures in live and fixed neural tissue, eLife 8 (2019). doi: 10.7554/elife.51101. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [43].Williamson N. H., Ravin R., Cai T. X., Rey J. A., Basser P. J., Passive water exchange between multiple sites can explain why apparent exchange rate constants depend on ionic and osmotic conditions in gray matter, Magnetic Resonance Letters (2025) 200225doi: 10.1016/j.mrl.2025.200225. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [44].Cheng Z., Hu S., Han G., Fang K., Jin X., Ordinola A., Özarslan E., Bai R., Using deep learning to accelerate magnetic resonance measurements of molecular exchange, The Journal of Chemical Physics 159 (5) (2023). doi: 10.1063/5.0159343. [DOI] [PubMed] [Google Scholar]
- [45].Herberthson M., Basser P. J., Özarslan E., Time-dependent diffusion in one-dimensional disordered media decorated by permeable membranes: Theoretical findings backed by simulations and a new disorder class, Physics of Fluids 37 (6) (2025). doi: 10.1063/5.0272370. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [46].Cai T. X., Williamson N. H., Ravin R., Herberthson M., Özarslan E., Basser P. J., Measuring the velocity autocorrelation function using diffusion nmr, The Journal of Chemical Physics 162 (17) (2025). doi: 10.1063/5.0258081. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [47].Callaghan P. T., A simple matrix formalism for spin echo analysis of restricted diffusion under generalized gradient waveforms, Journal of Magnetic Resonance 129 (1) (1997) 74–84. doi: 10.1006/jmre.1997.1233. [DOI] [PubMed] [Google Scholar]
- [48].Caprihan A., Wang L., Fukushima E., A multiple-narrow-pulse approximation for restricted diffusion in a time-varying field gradient, Journal of Magnetic Resonance, Series A 118 (1) (1996) 94–102. doi: 10.1006/jmra.1996.0013. [DOI] [Google Scholar]
- [49].Barzykin A., Theory of spin echo in restricted geometries under a step-wise gradient pulse sequence, Journal of Magnetic Resonance 139 (2) (1999) 342–353. doi: 10.1006/jmre.1999.1778. [DOI] [PubMed] [Google Scholar]
- [50].Grebenkov D. S., Nmr survey of reflected brownian motion, Reviews of Modern Physics 79 (3) (2007) 1077–1137. doi: 10.1103/revmodphys.79.1077. [DOI] [Google Scholar]
- [51].Grebenkov D. S., Laplacian eigenfunctions in nmr. i. a numerical tool, Concepts in Magnetic Resonance Part A 32A (4) (2008) 277–301. doi: 10.1002/cmr.a.20117. [DOI] [Google Scholar]
- [52].Herberthson M., Özarslan E., Knutsson H., Westin C.-F., Dynamics of local magnetization in the eigenbasis of the blochtorrey operator, The Journal of Chemical Physics 146 (12) (2017). doi: 10.1063/1.4978621. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [53].Zientara G. P., Freed J. H., Spin-echoes for diffusion in bounded, heterogeneous media: A numerical study, The Journal of Chemical Physics 72 (2) (1980) 1285–1292. doi: 10.1063/1.439190. [DOI] [Google Scholar]
- [54].Blees M., The effect of finite duration of gradient pulses on the pulsed-field-gradient nmr method for studying restricted diffusion, Journal of Magnetic Resonance, Series A 109 (2) (1994) 203–209. doi: 10.1006/jmra.1994.1156. [DOI] [Google Scholar]
- [55].Salikhov K. M., Schneider D. J., Saxena S., Freed J. H., A theoretical approach to the analysis of arbitrary pulses in magnetic resonance, Chemical Physics Letters 262 (1–2) (1996) 17–26. doi: 10.1016/0009-2614(96)01044-5. [DOI] [Google Scholar]
- [56].Sen P. N., André A., Axelrod S., Spin echoes of nuclear magnetization diffusing in a constant magnetic field gradient and in a restricted geometry, The Journal of Chemical Physics 111 (14) (1999) 6548–6555. doi: 10.1063/1.480009. [DOI] [Google Scholar]
- [57].Crank J., Nicolson P., A practical method for numerical evaluation of solutions of partial differential equations of the heat-conduction type, Mathematical Proceedings of the Cambridge Philosophical Society 43 (1) (1947) 50–67. doi: 10.1017/s0305004100023197. [DOI] [Google Scholar]
- [58].Trotter H. F., On the product of semi-groups of operators, Proceedings of the American Mathematical Society 10 (4) (1959) 545–551. doi: 10.1090/s0002-9939-1959-0108732-6. [DOI] [Google Scholar]
- [59].Neuman C. H., Spin echo of spins diffusing in a bounded medium, The Journal of Chemical Physics 60 (11) (1974) 4508–4511. doi: 10.1063/1.1680931. [DOI] [Google Scholar]
- [60].Le Bihan D., Breton E., Lallemand D., Grenier P., Cabanis E., Laval-Jeantet M., Mr imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders., Radiology 161 (2) (1986) 401–407. doi: 10.1148/radiology.161.2.3763909. [DOI] [PubMed] [Google Scholar]
- [61].Casanova F., Perlo J., Blumich B. (Eds.), Single-Sided NMR, 2011th Edition, Springer, Berlin, Germany, 2011. [Google Scholar]
- [62].Keller D., Erö C., Markram H., Cell densities in the mouse brain: A systematic review, Frontiers in Neuroanatomy 12 (2018). doi: 10.3389/fnana.2018.00083. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [63].Ianus A.¸, Carvalho J., Fernandes F. F., Cruz R., Chavarrias C., Palombo M., Shemesh N., Soma and neurite density mri (sandi) of the in-vivo mouse brain and comparison with the allen brain atlas, NeuroImage 254 (2022) 119135. doi: 10.1016/j.neuroimage.2022.119135. [DOI] [PubMed] [Google Scholar]
- [64].Shapson-Coe A., Januszewski M., Berger D. R., Pope A., Wu Y., Blakely T., Schalek R. L., Li P. H., Wang S., Maitin-Shepard J., Karlupia N., Dorkenwald S., Sjostedt E., Leavitt L., Lee D., Troidl J., Collman F., Bailey L., Fitzmaurice A., Kar R., Field B., Wu H., Wagner-Carena J., Aley D., Lau J., Lin Z., Wei D., Pfister H., Peleg A., Jain V., Lichtman J. W., A petavoxel fragment of human cerebral cortex reconstructed at nanoscale resolution, Science 384 (6696) (2024). doi: 10.1126/science.adk4858. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [65].Brownstein K. R., Tarr C. E., Importance of classical diffusion in nmr studies of water in biological cells, Physical Review A 19 (6) (1979) 2446–2453. doi: 10.1103/physreva.19.2446. [DOI] [Google Scholar]
- [66].Afrough A., Magnetic resonance relaxation in heterogeneous materials is analogous to first-order chemical reaction, Transport in Porous Media 151 (7) (2024) 1493–1509. doi: 10.1007/s11242-024-02075-y. [DOI] [Google Scholar]
- [67].Grebenkov D. S., Exploring diffusion across permeable barriers at high gradients. ii. localization regime, Journal of Magnetic Resonance 248 (2014) 164–176. doi: 10.1016/j.jmr.2014.08.016. [DOI] [PubMed] [Google Scholar]
- [68].Lee J. H., Labadie C., Springer C. S., Harbison G. S., Two-dimensional inverse laplace transform nmr: altered relaxation times allow detection of exchange correlation, Journal of the American Chemical Society 115 (17) (1993) 7761–7764. doi: 10.1021/ja00070a022. [DOI] [Google Scholar]
- [69].Washburn K. E., Callaghan P. T., Tracking pore to pore exchange using relaxation exchange spectroscopy, Physical Review Letters 97 (17) (2006). doi: 10.1103/physrevlett.97.175502. [DOI] [PubMed] [Google Scholar]
- [70].Ordinola A., Özarslan E., Bai R., Herberthson M., Limitations and generalizations of the first order kinetics reaction expression for modeling diffusion-driven exchange: Implications on nmr exchange measurements, The Journal of Chemical Physics 160 (8) (2024). doi: 10.1063/5.0188865. [DOI] [PubMed] [Google Scholar]
- [71].Lee H.-H., Wang N., Fieremans E., Huang S. Y., Novikov D. S., Localization regime of diffusion (lord) in mouse and pig cortical gray matter and its sensitivity to soma size, in: Proceedings of the 31st Annual Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM), Toronto, Canada, 2023, p. 0681. [Google Scholar]
- [72].Kac M., Can one hear the shape of a drum?, The American Mathematical Monthly 73 (4) (1966) 1. doi: 10.2307/2313748. [DOI] [Google Scholar]
- [73].Laun F. B., Kuder T. A., Semmler W., Stieltjes B., Determination of the defining boundary in nuclear magnetic resonance diffusion experiments, Physical Review Letters 107 (4) (2011). doi: 10.1103/physrevlett.107.048102. [DOI] [PubMed] [Google Scholar]
- [74].Song Y.-Q., Detection of the high eigenmodes of spin diffusion in porous media, Physical Review Letters 85 (18) (2000) 3878–3881. doi: 10.1103/physrevlett.85.3878. [DOI] [PubMed] [Google Scholar]
- [75].Callaghan P. T., Stepišnik J., Frequency-domain analysis of spin motion using modulated-gradient nmr, Journal of Magnetic Resonance, Series A 117 (1) (1995) 118–122. doi: 10.1006/jmra.1995.9959. [DOI] [Google Scholar]
- [76].Parsons E. C., Does M. D., Gore J. C., Temporal diffusion spectroscopy: Theory and implementation in restricted systems using oscillating gradients, Magnetic Resonance in Medicine 55 (1) (2005) 75–84. doi: 10.1002/mrm.20732. [DOI] [PubMed] [Google Scholar]
- [77].Ordinola A., Cai S., Lundberg P., Bai R., Özarslan E., On the sampling strategies and models for measuring diffusion exchange with a double diffusion encoding sequence, Magnetic Resonance Letters 3 (3) (2023) 232–247. doi: 10.1016/j.mrl.2023.05.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [78].Hansen P., The l-curve and its use in the numerical treatment of inverse problems, in: InviteComputational Inverse Problems in Electrocardiology, WIT Press, 2000, pp. 119–142. [Google Scholar]
- [79].Song R., Song Y.-Q., Vembusubramanian M., Paulsen J. L., The robust identification of exchange from t2–t2 time-domain features, Journal of Magnetic Resonance 265 (2016) 164–171. doi: 10.1016/j.jmr.2016.02.001. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The MATLAB code and simulated or generated data are available upon reasonable request.



