Extract
We thank H. Zhao and co-workers for their thoughtful and constructive comments on our recent integrative review [1], which aimed to synthesise emerging diaphragm ultrasound techniques across clinical contexts with an emphasis on reliability, physiological interpretation and clinical applicability. We welcome the opportunity to further clarify several methodological and physiological aspects raised in their correspondence.
Shareable abstract
Emerging diaphragm ultrasound techniques provide complementary insights into respiratory muscle function. Careful physiological interpretation and methodological standardisation remain essential for meaningful use of PW-TDI and shear wave elastography. https://bit.ly/4baEqE0
Reply to H. Zhao and co-workers:
We thank H. Zhao and co-workers for their thoughtful and constructive comments on our recent integrative review [1], which aimed to synthesise emerging diaphragm ultrasound techniques across clinical contexts with an emphasis on reliability, physiological interpretation and clinical applicability. We welcome the opportunity to further clarify several methodological and physiological aspects raised in their correspondence.
An important clarification relates to comparisons between M-mode-derived metrics and pulsed-wave tissue Doppler imaging (PW-TDI) parameters. Although both assess diaphragm motion, they rely on different measurement constructs: M-mode excursion reflects global diaphragmatic displacement over time, whereas PW-TDI measures instantaneous local tissue velocity within a specific sampling volume. Consequently, direct interchangeability between parameters derived from these techniques should not be assumed, as their relationship is unlikely to be linear. For example, velocity–time integral (VTI) from PW-TDI provides a displacement-equivalent parameter, yet in a weaning study it did not consistently approximate M-mode excursion [2]. Accordingly, PW-TDI may be viewed as a granularity-enriched approach providing enhanced insight into diaphragmatic displacement kinetics [3], complementing conventional excursion-based assessment, as highlighted by H. Zhao and co-workers.
Furthermore, PW-TDI measurements are strongly influenced by probe orientation, fibre alignment and tissue sampling, such that recorded motion reflects only fibres within the Doppler region. During assisted ventilation, displacement may result from both active contraction and passive ventilator-driven movement, and variability in ventilatory support may affect velocity measurements and reproducibility.
Peak diaphragm contraction velocity (peak-DCV) correlates with parameters of transdiaphragmatic pressure and may reflect inspiratory force generation; however, motion-derived ultrasound indices integrate neural respiratory drive, loading conditions and thoracoabdominal mechanics rather than isolated contractile properties. Increases in peak-DCV reported in patients with weaning failure [2, 4] should therefore be interpreted cautiously. Consistent with this complexity, diaphragmatic excursion has shown limited association with respiratory effort in both assisted and unassisted breathing conditions [5, 6].
For these reasons, we do not consider the reported divergence between higher peak-DCV values and lower mean diaphragm contraction velocity (mean-DCV, from M-mode) to represent a physiological contradiction. Rather, excursion-over-time metrics are influenced by respiratory drive and mechanical conditions, and therefore should not be interpreted as direct indicators of diaphragmatic endurance as mentioned. In evolving respiratory muscle failure, compensatory strategies may favour increased respiratory frequency rather than greater displacement, resulting in rapid shallow breathing patterns reflected in indices such as the rapid shallow breathing index [7]. Increases in peak-DCV may thus represent adaptive breathing responses to increased load; interpretation should therefore remain grounded in the broader physiological context and consider ultrasound acquisition conditions.
Shear wave elastography (SWE) bridges imaging and biomechanics, and offers potential for advanced assessment of respiratory muscle mechanical properties. As noted in the correspondence, muscle anisotropy is a key factor influencing measurements [8, 9].
While anisotropy, reflecting the directional dependence of mechanical behaviour relative to muscle fibre orientation, is an inherent biomechanical feature of skeletal muscle, the need for multidirectional SWE assessment should be balanced against clinical feasibility, reproducibility and incremental diagnostic value. The diaphragm's unique geometry and architecture introduce additional challenges for consistent multidirectional measurements compared with the limb muscles commonly studied with elastography. We agree that dual-direction SWE assessment may enrich biomechanical characterisation. Nevertheless, in clinical practice, a technically robust and reproducible single-plane approach may remain clinically informative and should not be considered insufficient, particularly when supported by reproducibility data. Further studies are needed to clarify the clinical implications of multidirectional measurements.
Acquisition in a plane transverse to the muscle fibres may pose technical challenges related to diaphragmatic motion and intercostal acoustic windows. Depending on probe positioning, breathing pattern and underlying respiratory conditions (e.g. hyperinflation or diaphragm flattening), consistent visualisation may be difficult to maintain. Transverse measurements have shown lower inter-operator reproducibility than longitudinal acquisitions, whereas longitudinal orientation has demonstrated good to excellent reliability in both healthy individuals and critically ill patients [10].
Regarding probe orientation, our interpretation of cited studies differs from that proposed in the correspondence. Aarab et al. [11] explicitly describe rotation of the probe to achieve alignment parallel to diaphragm muscle fascicles, consistent with prior reliability studies from the same group [10]. More broadly, diaphragmatic SWE measurements depend strongly on acquisition conditions, including probe orientation/positioning and respiratory phase, as stiffness reflects both passive tissue properties and active muscle state; these factors should be explicitly considered when interpreting SWE-derived stiffness values.
Emerging diaphragm ultrasound techniques provide a multidimensional perspective integrating structural, mechanical and functional domains. Clinical translation requires methodological standardisation, clearer physiological interpretation and validation of meaningful outcomes. Until stronger evidence clarifies relationships between modalities, cautious interpretation remains essential.
Acknowledgements
The authors sincerely thank the Private Foundation of the Geneva University Hospitals (Fondation privée des HUG) for its valuable support in promoting research and innovation throughout this project. The authors used ChatGPT (OpenAI) as a writing assistance tool to support language refinement and editing of the manuscript during preparation and revision. All content was reviewed and validated by the authors, who retain full responsibility for the final manuscript.
Footnotes
Provenance: Invited article, peer reviewed.
Author contributions: I. Neto Silva and K. Bendjelid conceived the manuscript. I. Neto Silva prepared the first draft, and both authors contributed to critical revision and approved the final version.
Conflict of interest: All authors have nothing to disclose.
Support statement: This research was supported by a grant from the Private Foundation of the Geneva University Hospitals (RELÈVE HUG RLV01S-02), awarded to I. Neto Silva to partially cover protected research time dedicated to the completion of his doctoral thesis. Funding information for this article has been deposited with the Open Funder Registry.
References
- 1.Neto Silva I, Bennett C, Duarte JA, et al. Ultrasound innovations in diaphragm assessment: an integrative review of expanding clinical applications. Eur Respir Rev 2025; 34: 250089. doi: 10.1183/16000617.0089-2025 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Soilemezi E, Savvidou S, Sotiriou P, et al. Tissue Doppler imaging of the diaphragm in healthy subjects and critically ill patients. Am J Respir Crit Care Med 2020; 202: 1005–1012. doi: 10.1164/rccm.201912-2341OC [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Cammarota G, Boniolo E, Tarquini R, et al. Diaphragmatic excursion tissue Doppler sonographic assessment. Intensive Care Med 2020; 46: 1759–1760. doi: 10.1007/s00134-020-06015-4 [DOI] [PubMed] [Google Scholar]
- 4.Cammarota G, Boniolo E, Santangelo E, et al. Diaphragmatic kinetics assessment by tissue Doppler imaging and extubation outcome. Respir Care 2021; 66: 983–993. doi: 10.4187/respcare.08702 [DOI] [PubMed] [Google Scholar]
- 5.Spiesshoefer J, Herkenrath S, Henke C, et al. Evaluation of respiratory muscle strength and diaphragm ultrasound: normative values, theoretical considerations, and practical recommendations. Respiration 2020; 99: 369–381. doi: 10.1159/000506016 [DOI] [PubMed] [Google Scholar]
- 6.Umbrello M, Formenti P, Longhi D, et al. Diaphragm ultrasound as indicator of respiratory effort in critically ill patients undergoing assisted mechanical ventilation: a pilot clinical study. Crit Care 2015; 19: 161. doi: 10.1186/s13054-015-0894-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Yang KL, Tobin MJ. A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991; 324: 1445–1450. doi: 10.1056/NEJM199105233242101 [DOI] [PubMed] [Google Scholar]
- 8.Gennisson J-L, Deffieux T, Mace E, et al. Viscoelastic and anisotropic mechanical properties of in vivo muscle tissue assessed by supersonic shear imaging. Ultrasound Med Biol 2010; 36: 789–801. doi: 10.1016/j.ultrasmedbio.2010.02.013 [DOI] [PubMed] [Google Scholar]
- 9.Dorado Cortez C, Hermitte L, Ramain A, et al. Ultrasound shear wave velocity in skeletal muscle: a reproducibility study. Diagn Interv Imaging 2016; 97: 71–79. doi: 10.1016/j.diii.2015.05.010 [DOI] [PubMed] [Google Scholar]
- 10.Flatres A, Aarab Y, Nougaret S, et al. Real-time shear wave ultrasound elastography: a new tool for the evaluation of diaphragm and limb muscle stiffness in critically ill patients. Crit Care 2020; 24: 34. doi: 10.1186/s13054-020-2745-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Aarab Y, Flatres A, Garnier F, et al. Shear wave elastography, a new tool for diaphragmatic qualitative assessment: a translational study. Am J Respir Crit Care Med 2021; 204: 797–806. doi: 10.1164/rccm.202011-4086OC [DOI] [PubMed] [Google Scholar]
