PSD-LW-DCN: a generalizable power spectral density based lightweight deep convolutional neural network for seizure detection

Peipei Gu 1,#, Ming Zhang 2,#, Meiyan Xu 3, Duo Chen 4,✉, Jibin Shou 1, Jiayang Guo 5, Naian Xiao 6,7,✉
PMCID: PMC13136392  PMID: 41851280

Abstract

Objective: Cross-subject generalization in EEG-based seizure detection remains a significant challenge due to diverse physiological differences among patients, which can degrade model performance across individuals. This work aims to develop a robust, lightweight, and fast-deployable model for cross-subject seizure detection that achieves high accuracy while enabling real-time, low-latency inference on resource-constrained devices. Methods: We propose PSD-LW-DCN, a novel lightweight deep convolutional network that leverages power spectral density (PSD) features extracted via multitaper spectral estimation. Raw EEG signals are preprocessed through bandpass filtering, segmentation, and class balancing. PSD features are computed across multiple frequency bands (Inline graphic,Inline graphic,Inline graphic,Inline graphic,Inline graphic), averaged across channels to enhance generalizability, and concatenated as input to the network. The model was trained and evaluated separately on the CHB-MIT and TUSZ datasets, with no data mixing between them. Results: With only 61,218 parameters, PSD-LW-DCN achieves state-of-the-art efficiency, reducing inference time to 1.9 ms/sample on CHB-MIT and 2.1 ms/sample on TUSZ, demonstrating its suitability for real-time applications. It attains 85.84% accuracy on CHB-MIT and 83.21% on TUSZ, representing improvements of 5% and 3%, respectively, over previous approaches. Notably, the model shows strong cross-subject generalization and robustness across diverse patient populations. In clinically meaningful event-based evaluation, it achieves a low false alarm rate of 0.33 false alarms per hour (FA/h) on CHB-MIT and 1.09 FA/h on TUSZ, indicating high operational reliability in long-term monitoring scenarios. Conclusions: PSD-LW-DCN offers an optimal balance between accuracy, speed, and model size, making it highly suitable for real-time, edge-based clinical diagnosis of epilepsy. Its efficiency and low false alarm burden confirm its potential for deployment in low-power wearable and point-of-care systems. Future work will focus on further reducing the false alarm rate, particularly in more heterogeneous datasets like TUSZ, to enhance clinical usability.

Keywords: Seizure detection, Cross-subject, Power spectral density, EEG

Subject terms: Computational biology and bioinformatics, Engineering, Health care, Medical research, Neurology, Neuroscience

Introduction

Electroencephalography (EEG) is essential for diagnosing neurological disease1, capturing dynamic brain electrical activity. It plays a crucial role in identifying epilepsy types, diagnosing syndromes, and assessing recurrence risks2. However, traditional manual EEG analysis is manual, subjective, and highly dependent on specific datasets, making it less generalizable and prone to inter-expert variability, which leads to inefficient and inconsistent resource utilization3. Given the complexity and variability of EEG patterns during seizures, there is a growing need for automated EEG processing systems to improve detection accuracy, consistency, and efficiency4. Existing approaches typically involve segmenting raw EEG signals, extracting features, and using neural networks or machine learning for classification, aiming to reduce clinician burden and enhance diagnostic precision5,6.

Feature extraction is essential for identifying epileptic activities, traditionally relying on manual methods in time, frequency, and nonlinear domains, which are labor-intensive and impact model performance7. To address these limitations, various improvements have been proposed, such as optimization algorithms for SVM8, Kernel Sparse Representation Classification (KSRC)9, and AdaBoost LS-SVM frameworks10. However, feature extraction remains a bottleneck. Deep learning techniques, including CNNs, RNNs, and BiLSTMs, have been widely adopted to automate feature extraction11–13. Recent studies have further explored their potential, such as transformer-based algorithms14, 1D-CNN with data augmentation15, EEGWaveNet16, adversarial neural networks17, dynamic EEG channel selection18, multi-head self-attention mechanisms19, LDA-LASSO framework for selecting minimal EEG channels and features to achieve seizure detection20. Despite these advancements, challenges in feature extraction and model generalization persist.

EEG signals are easily affected by physiological noise, making the extraction of epileptic features challenging. Traditional methods such as power spectral density (PSD) have been widely used for EEG classification. For example, PSD parameterization was employed to separate periodic and aperiodic components of EEG signals and validated on two public datasets for epilepsy detection21. Similarly, a hypergraph network framework combined PSD with Conv-LSTM to capture temporal-spatial and frequency domain features22. Additionally, a CNN model (AlexNet) was trained using PSD-encoded images constructed from all channels at different time periods23. However, these methods often suffer from high computational complexity, limited robustness to inter-subject variability, and suboptimal representation of spectral dynamics.

To address these limitations, recent studies have introduced adaptive channel selection strategies and deep learning models. For example, an adaptive channel selection module was proposed to identify seizure-relevant channels using EEG power spectral features24. Empirical Mode Decomposition (EMD) combined with PSD was also used as input to CNNs for improved feature extraction25. Cross-subject seizure detection remains challenging due to the non-stationarity of EEG signals. Recent approaches include leveraging weak labels to train Dense-CNN models26, multi-view feature fusion based on adversarial learning27, and Self-Organizing Fuzzy Logic (SOF) classifiers for both cross-patient and patient-specific detection28. Other methods combine CNN and LSTM for distinguishing seizure types29 and use frameworks like SeizureNet to classify seizure types by integrating information from different frequency bands30.

Building on the challenges of detecting different patient states and the need for efficient deployment in resource-constrained environments, we propose a highly automated, PSD-based lightweight deep convolutional neural network. By directly learning discriminative spectral patterns from aggregated per-channel PSD features, without explicit spatial modeling, the proposed model achieves accurate seizure detection with a lightweight design ideal for real-world clinical deployment.

The main contributions of this paper are as follows.

  • We propose PSD-LW-DCN, a unified framework that synergizes PSD analysis with a lightweight Deep Convolutional Network. This integration explicitly bridges the gap between spectral feature extraction and deep representation learning to tackle the challenge of cross-subject seizure detection.

  • Motivated by the practical need for edge deployment, we developed a lightweight framework where signal preprocessing simplifies the downstream neural workload. This co-optimized approach allows for robust seizure detection on resource-constrained devices without sacrificing accuracy.

  • We validate the co-design rationale through a systematic analysis of EEG energy variations across seizure states. This confirms that coupling explicit energy-based features with learnable convolutional features captures the intrinsic dynamics of seizures better than either approach in isolation.

Methodology

Seizure detection

Seizure detection involves the automatic identification of epileptic seizure events from continuous EEG recordings, aiming to distinguish ictal periods from interictal states with high accuracy and low false detection rates. This task is challenging due to the complex, non-stationary, and patient-specific nature of EEG signals. Effective seizure detection models are crucial for assisting clinicians in epilepsy diagnosis, reducing the manual burden of EEG review, and enabling real-time monitoring in clinical and home settings.

Description of the dataset

The experiments were conducted separately on two benchmark datasets: the CHB-MIT dataset from Boston Children’s Hospital and the Massachusetts Institute of Technology (CHB-MIT)31, and the Temple University Hospital Seizure(TUSZ) dataset32.

The CHB-MIT database contains 940 hours of long-term, continuous, multi-channel EEG recordings from 23 epilepsy subjects aged between 1.5 and 22 years. Data on CHB01 and CHB21 were collected from the same patient, 1.5 years apart. The EEG signals were sampled at a frequency of 256 Hz, with at least 19 channels recorded according to the international 10–20 system. The dataset includes 198 seizures, with the onset and offset of each seizure precisely annotated by clinicians with expertise in neuroscience.

The TUH EEG dataset is currently the largest publicly available EEG dataset. The TUSZ dataset is a subset of TUH dataset. The EEG signals were sampled at 250 Hz with a 16-bit resolution, and the recordings were acquired using 20 to 128 channels. The TUSZ dataset contains manually annotated EEG seizure event data, including start time, stop time, channels, and seizure types. It comprises 1,643 sessions, 675 patients, and 3,971 seizure events, with a total seizure duration of 1,474 hours.

Since the TUSZ dataset contains many subjects but with varying total seizure durations, we selected the 20 subjects with the longest seizure durations under the same montage configuration, in order to ensure consistency in channels and montage.

Preprocessing

During EEG signal collection, noise such as power line interference (50–60 Hz) and eye movement artifacts can be introduced. To remove ocular and muscular artifacts, we first applied Independent Component Analysis (ICA) as part of the preprocessing pipeline. Then, to retain seizure-related information while suppressing high-frequency noise and power line interference, a 0.5–50 Hz FIR band-pass filter was applied. The long-duration signals were then segmented into 4-second intervals to simplify analysis and enhance computational efficiency while capturing meaningful EEG patterns33–35. On the CHB-MIT dataset, we used the commonly adopted 18 EEG channels, while on the TUSZ dataset, we used the standard 20-channel36,37. All data were strictly partitioned according to the labels provided by the datasets. Boundary segments overlapping seizure intervals were preserved and labeled as ictal if any part of the segment fell within the clinically annotated seizure period. As shown in Table 1, the original sample sizes were presented. Next, interictal samples were downsampled to achieve class balance, ensuring that result biases caused by sample imbalance were avoided. Ultimately, 59,346 samples (29,673 ictal and 29,673 interictal) were obtained from the CHB-MIT dataset, and 108,976 samples (54,488 ictal and 54,488 interictal) were obtained from the TUSZ dataset. Subsequently, Z-score normalization was applied using statistics computed from the training dataset in each leave-one-out cross-validation fold, ensuring consistency and enhancing the convergence efficiency of the deep learning models.

Table 1.

Original sample sizes on the two datasets.

Dataset Ictal Interictal
CHB-MIT 29,673 77,850
TUSZ 54,488 121,022

Lightweight high-performance deep convolutional neural network

As illustrated in Fig. 1, the EEG signal is processed through a series of steps. Initially, bandpass filtering is applied to the signal, followed by segmentation into 4-second intervals. After preprocessing, PSD features are extracted and concatenated. These fused features are then processed through the Conv 1 module to extract high-dimensional features, and further processed through the Conv 2 module to extract low-dimensional features. Finally, the features are flattened and passed through two fully connected layers for classification of ictal and interictal states.

Fig. 1.

Fig. 1

The overall framework of our proposed method.

Feature fusion

(1) Frequency band division

The EEG signals were decomposed into five canonical physiological frequency bands: Inline graphic(0.5–4.5 Hz), Inline graphic(4–8 Hz), Inline graphic(8–13 Hz), Inline graphic(13–30 Hz), and Inline graphic(30–50 Hz). For each channel, bandpass filtering was applied to extract the corresponding band-limited components, resulting in five filtered versions of the original multi-channel signal, each representing neural activity within a specific frequency range. Subsequently, power spectral density (PSD) features for each band were computed from the segmented raw data using the multitaper method (MTM), a robust spectral estimation technique that reduces variance through orthogonal tapers.

(2) Calculation of Power Spectral Density

The MTM is a sophisticated technique for estimating PSD38, involving three essential steps: selection of orthogonal windows, individual PSD estimation, and averaging.

Selection of Orthogonal Windows

A set of Inline graphic data windows, which are mutually orthogonal, are chosen from the Slepian function set or Discrete Prolate Spheroidal Sequences (DPSS). For a given time series length Inline graphic and bandwidth parameter Inline graphic, one can find a set of Inline graphic mutually orthogonal tapers Inline graphic, where Inline graphic.

Individual PSD Estimation

For each taper, the original time series is multiplied by that taper to produce a new time series, which is then Fourier transformed to obtain the corresponding PSD estimate. Assuming we have a time series Inline graphic, the PSD estimate using the Inline graphicth taper Inline graphic is calculated as follows:

graphic file with name d33e634.gif 1

Here, Inline graphic denotes frequency, Inline graphic is the imaginary unit, and Inline graphic is the complex exponential function used to transform the time-domain signal into the frequency domain.

Averaging Process

All Inline graphic individual PSD estimates produced by the tapers are summed to compute the average PSD:

graphic file with name d33e663.gif 2

The PSD values were averaged across the channel dimension and then combined across the five frequency bands. After averaging, the resulting PSD representation is one-dimensional (1D) with respect to time and frequency band, which preserves spectral characteristics while reducing spatial variability. This 1D feature vector is then used as the input to the PSD-LW-DCN model. This design is pivotal for our lightweight framework. it minimizes spatial variability, and thus model complexity, while retaining comprehensive spectral information.

Model classification

The PSD-LW-DCN model is designed for cross-subject seizure detection, incorporating two feature extraction modules, Conv Module 1 and Conv Module 2, which process reconstructed PSD features sequentially.

The use of two convolutional modules enables the network to learn progressively more complex spectral patterns while maintaining a lightweight architecture, which is crucial for efficient deployment in resource-constrained clinical environments. During preliminary experiments, we observed that adding a third convolutional module did not yield significant performance improvements but substantially increased model size and computational cost. In contrast, a single-layer design was insufficient to capture the hierarchical spectral dynamics required for robust seizure detection. Therefore, two modules were selected as an optimal trade-off between representational capacity, model compactness, and inference efficiency within the PSD-LW-DCN framework.

Conv Module 1 consists of two convolutional blocks: the first includes a convolutional layer (32 kernels, size 3, stride 1), a batch normalization layer, and a max-pooling layer (kernel size 2, stride 1); the second block includes a convolutional layer (32 kernels, size 3, stride 1), a max-pooling layer (kernel size 2, stride 1), and a batch normalization layer.

Conv Module 2 mirrors this structure but omits the max-pooling layer in the second block. The high-level representations from Module 2 are concatenated and passed through two fully connected layers for final classification.

Experiments

In this section, the experimental setup is detailed, encompassing data evaluation metrics and implementation details. These components are critical for ensuring the rigor and reproducibility of the experiments.

Evaluation metrics

The performance of the proposed model was evaluated using accuracy, sensitivity, specificity, F1 score, AUC, and false alarms per hour.

Accuracy measures the overall proportion of correct predictions:

graphic file with name d33e688.gif 3

where TP (True Positive) and TN (True Negative) are correctly classified seizure and non-seizure samples, FP (False Positive) are incorrect seizure predictions, and FN (False Negative) are missed seizures.

Sensitivity (recall) measures the model’s ability to detect actual seizures:

graphic file with name d33e695.gif 4

Specificity measures the proportion of non-seizure events correctly identified:

graphic file with name d33e700.gif 5

The F1 score is the harmonic mean of precision and recall, providing a balanced measure for imbalanced data:

graphic file with name d33e705.gif 6

AUC (Area Under the ROC Curve) evaluates the model’s overall discriminative ability between seizure and non-seizure classes.

A predicted seizure is considered a true positive if it occurs within 30 seconds before or 60 seconds after a true seizure onset; otherwise, it is counted as a false alarm. This asymmetric event-based matching protocol—allowing for early detection and delayed response—follows the standardized evaluation framework defined in SzCORE39, ensuring clinically meaningful and comparable assessment across studies.

Building on this event-based evaluation, the false alarm rate per hour is reported to assess the model’s clinical reliability in long-term monitoring. It is computed for each subject as:

graphic file with name d33e718.gif 7

where a false alarm event is any predicted seizure that does not align with a true seizure within the Inline graphic to Inline graphic seconds tolerance window. This metric provides a practical measure of system usability, helping to quantify the risk of alarm fatigue in real-world clinical environments.

Together, these metrics provide a comprehensive evaluation of both performance and real-world applicability.

Experimental setup

To ensure the robustness and validity of the proposed model, leave-one-out cross-validation (LOOCV) was employed for evaluation. This method iteratively selects N-1 subjects for training and one subject for testing, ensuring reliable model assessment. The overall accuracy is computed as the average precision across all iterations.

The model was trained and validated on two publicly available datasets, CHB-MIT and TUSZ, using the cross-entropy loss function and optimized with the Adam optimizer. The best model weights were selected based on the minimum validation loss achieved during training, using an early stopping mechanism with a patience of 10 epochs to prevent overfitting. All implementations utilized PyTorch, an open-source deep learning framework.

Experimental results and discussion

Performance evaluation In CHB-MIT

As shown in Table 2, the proposed model achieves an average accuracy of 85.84% ± 10.13%, sensitivity of 79.57% ± 15.64%, specificity of 92.12% ± 14.78%, AUC of 0.94 ± 0.09, F1 score of 0.84 ± 0.11, and a low false alarm rate of 0.33 ± 0.37 per hour. High performance is observed in subjects like chb01, chb02, and chb22 (accuracy >96%, F1 Inline graphic 0.96, <0.1 false alarms/h), while chb02 and chb09 achieve near-perfect sensitivity (100.00% and 99.21%), and chb01/chb04 show high specificity (>99.3%). Most subjects (chb17/chb23) have fewer than 0.5 false alarms per hour, indicating strong clinical feasibility. However, performance declines in subjects with atypical physiology, chb14 exhibits low accuracy (61.50%) and sensitivity (39.56%), chb06 has poor specificity (51.99%), and chb05 suffers from high false alarms (1.64/h), suggesting limited generalizability for some individuals. Overall, the model demonstrates robust seizure detection with high specificity and low false alarms across most subjects, highlighting its potential for real-world epilepsy diagnosis.

Table 2.

Cross-subject experimental results based on the CHB-MIT dataset, using a leave-one-out strategy.

ID Acc (%) Sen (%) Spe (%) AUC F1 False alarms per hour
chb01 96.42 93.47 99.34 0.99 0.96 0.03
chb02 99.14 100.00 98.28 0.99 0.99 0.08
chb03 87.56 79.35 95.62 0.97 0.86 0.22
chb04 90.22 81.11 99.33 0.98 0.89 0.01
chb05 91.57 99.04 83.98 0.98 0.92 1.64
chb06 68.19 84.53 51.99 0.80 0.72 0.20
chb07 93.01 93.49 92.51 0.96 0.93 0.18
chb08 87.25 80.19 94.38 0.94 0.86 0.96
chb09 88.96 99.21 78.52 0.98 0.90 0.44
chb10 89.13 90.89 87.36 0.96 0.89 0.36
chb11 89.54 81.33 97.73 0.97 0.88 0.55
chb12 84.14 76.05 92.20 0.93 0.82 0.51
chb13 80.52 70.09 91.08 0.89 0.78 0.52
chb14 61.50 39.56 83.33 0.64 0.50 0.32
chb15 90.12 86.83 93.40 0.95 0.89 0.80
chb16 81.11 68.42 93.55 0.93 0.78 0.05
chb17 83.93 69.41 98.63 0.97 0.80 0.12
chb18 85.86 75.00 96.71 0.95 0.84 0.15
chb19 87.63 79.26 96.11 0.96 0.86 0.27
chb20 81.42 64.05 99.08 0.96 0.77 0.03
chb21 71.17 43.15 99.25 0.90 0.59 0.03
chb22 96.40 95.68 97.12 0.99 0.96 0.17
chb23 84.98 73.41 96.52 0.94 0.83 0.11
chb24 90.53 86.14 94.92 0.96 0.90 0.18
Mean±Std 85.84±10.13 79.57±15.64 92.12±14.78 0.94±0.09 0.84±0.11 0.33±0.37

Performance evaluation In TUSZ

As shown in Table 3, the proposed model achieves competitive performance on the TUSZ dataset with an average accuracy of 83.21% ± 6.57%, sensitivity of 78.02% ± 10.32%, specificity of 88.39% ± 7.48%, AUC of 0.91 ± 0.07, F1 score of 0.81 ± 0.08, and a false alarm rate of 1.09 ± 0.75 per hour. High-performing subjects such as PN19 (accuracy: 97.52%, F1: 0.97, false alarms: 0.02/h) and PN20 (92.92%, F1: 0.92, 0.50/h) demonstrate strong detection reliability, while PN09 and PN19 achieve high sensitivities (96.91% and 95.22%) and PN19 attains near-perfect specificity (99.79%). The majority of subjects show balanced F1 scores (mean 0.81) and moderate false alarm rates, though some exhibit higher alerts (e.g., PN17: 2.98/h) or lower sensitivity (e.g., PN04: 62.38%), indicating variability across individuals. Overall, the model shows good generalization capability in cross-subject seizure detection with consistent accuracy, acceptable F1 scores, and manageable false alarms, highlighting its potential for clinical application in epilepsy monitoring.

Table 3.

Cross-subject experimental results based on the TUSZ dataset, using a leave-one-out strategy.

ID Acc (%) Sen (%) Spe (%) AUC F1 False alarms per hour
PN01 89.27 88.39 90.17 0.96 0.89 1.08
PN02 80.49 79.67 81.30 0.88 0.80 1.04
PN03 79.10 77.23 80.96 0.87 0.78 1.71
PN04 69.46 62.38 76.52 0.77 0.67 2.10
PN05 90.47 88.09 92.85 0.96 0.90 0.78
PN06 87.31 81.38 93.23 0.94 0.86 0.74
PN07 74.49 55.68 93.34 0.85 0.68 0.73
PN08 79.01 71.78 86.20 0.88 0.77 1.38
PN09 87.94 96.91 79.04 0.93 0.88 1.50
PN10 90.10 82.42 97.76 0.98 0.89 0.23
PN11 88.38 89.72 87.04 0.94 0.88 1.39
PN12 78.72 66.97 90.48 0.89 0.75 1.05
PN13 80.73 68.26 93.18 0.90 0.77 0.79
PN14 80.84 63.23 98.47 0.96 0.76 0.16
PN15 86.24 76.26 96.33 0.96 0.84 0.41
PN16 79.40 68.12 90.61 0.89 0.76 0.98
PN17 71.45 75.31 67.54 0.76 0.72 2.98
PN18 80.30 81.99 78.62 0.88 0.80 2.26
PN19 97.52 95.22 99.79 0.99 0.97 0.02
PN20 92.92 91.49 94.33 0.98 0.92 0.50
Mean±Std 83.21±6.57 78.02±10.32 88.39±7.48 0.91±0.07 0.81±0.08 1.09±0.75

Interpretability analysis

For interpretability analysis, subjects with varying classification performance (good, moderate, and poor) were selected from the CHB-MIT and TUSZ datasets. Their EEG signals were annotated by experts for epilepsy diagnosis. As shown in Fig. 2, subjects with good classification performance (e.g., chb01 and PN19) exhibited significant increases in PSD values during seizure periods across most frequency bands. In contrast, subjects with moderate or poor performance (e.g., chb14 and PN04) showed higher PSD values during interictal periods in certain frequency bands. This suggests that the lack of a clear energy difference between interictal and seizure periods in specific frequency bands may contribute to reduced classification accuracy. These findings highlight the importance of considering individual variability in EEG signal characteristics when interpreting model performance.

Fig. 2.

Fig. 2

Interpretability analysis in the CHB-MIT dataset and the TUSZ dataset.

Ablation study

Ablation experiments systematically evaluated the contribution of individual and combined frequency bands (Inline graphic, Inline graphic, Inline graphic, Inline graphic and Inline graphic) to cross-subject seizure detection on CHB-MIT and TUH datasets, with detailed results presented in Tables 4 and 5.

Table 4.

Ablation results on CHB-MIT dataset.

Dataset Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Acc (%) Sen (%) Spe (%) AUC F1
CHB-MIT Inline graphic 72.91 67.09 78.66 0.81 0.69
Inline graphic 73.97 69.60 78.33 0.83 0.71
Inline graphic 67.10 61.50 72.69 0.76 0.64
Inline graphic 72.81 67.19 78.76 0.81 0.70
Inline graphic 77.25 70.13 83.31 0.85 0.73
Inline graphic Inline graphic 77.30 70.47 84.11 0.86 0.76
Inline graphic Inline graphic 76.48 68.58 84.35 0.86 0.75
Inline graphic Inline graphic 79.80 71.89 86.70 0.88 0.77
Inline graphic Inline graphic 76.87 71.56 82.16 0.86 0.76
Inline graphic Inline graphic 77.16 71.27 84.03 0.87 0.79
Inline graphic Inline graphic 77.28 70.12 85.42 0.87 0.79
Inline graphic Inline graphic 75.67 70.68 80.63 0.84 0.75
Inline graphic Inline graphic 77.13 73.15 81.11 0.85 0.77
Inline graphic Inline graphic 80.43 73.21 87.65 0.89 0.80
Inline graphic Inline graphic 79.48 72.45 86.49 0.88 0.80
Inline graphic Inline graphic Inline graphic 80.15 72.16 88.13 0.88 0.79
Inline graphic Inline graphic Inline graphic 81.11 73.53 88.69 0.91 0.82
Inline graphic Inline graphic Inline graphic 82.28 75.31 89.23 0.93 0.83
Inline graphic Inline graphic Inline graphic 84.14 77.94 90.34 0.93 0.83
Inline graphic Inline graphic Inline graphic 78.82 72.45 85.18 0.88 0.78
Inline graphic Inline graphic Inline graphic 82.70 76.22 89.17 0.92 0.82
Inline graphic Inline graphic Inline graphic 81.46 74.62 88.28 0.90 0.81
Inline graphic Inline graphic Inline graphic 80.87 72.80 88.95 0.89 0.80
Inline graphic Inline graphic Inline graphic 81.16 74.35 87.97 0.90 0.81
Inline graphic Inline graphic Inline graphic 83.41 76.81 90.02 0.92 0.83
Inline graphic Inline graphic Inline graphic Inline graphic 84.60 78.34 90.87 0.93 0.83
Inline graphic Inline graphic Inline graphic Inline graphic 82.61 75.27 89.96 0.91 0.82
Inline graphic Inline graphic Inline graphic Inline graphic 84.25 77.88 90.60 0.93 0.83
Inline graphic Inline graphic Inline graphic Inline graphic 85.68 80.03 91.34 0.94 0.84
Inline graphic Inline graphic Inline graphic Inline graphic 83.90 77.45 90.37 0.92 0.82
Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic 85.84 79.57 92.12 0.94 0.84

Note:Inline graphicindicates whether to use this frequency band.

Table 5.

Ablation results on TUSZ dataset.

Dataset Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic Acc (%) Sen (%) Spe (%) AUC F1
TUSZ Inline graphic 69.48 65.46 73.96 0.78 0.66
Inline graphic 70.56 66.56 74.53 0.79 0.67
Inline graphic 68.12 62.25 71.36 0.76 0.64
Inline graphic 71.31 65.24 76.21 0.80 0.70
Inline graphic 74.12 72.24 81.31 0.83 0.71
Inline graphic Inline graphic 76.43 70.11 83.31 0.85 0.73
Inline graphic Inline graphic 74.83 67.89 83.85 0.83 0.71
Inline graphic Inline graphic 78.61 70.82 85.56 0.87 0.79
Inline graphic Inline graphic 74.82 70.64 81.56 0.84 0.75
Inline graphic Inline graphic 75.16 72.27 85.03 0.86 0.76
Inline graphic Inline graphic 76.12 69.12 84.42 0.85 0.73
Inline graphic Inline graphic 74.27 70.14 79.33 0.82 0.71
Inline graphic Inline graphic 76.34 72.45 80.61 0.85 0.73
Inline graphic Inline graphic 79.63 72.15 86.25 0.88 0.80
Inline graphic Inline graphic 78.32 71.35 85.29 0.87 0.79
Inline graphic Inline graphic Inline graphic 79.25 71.17 87.43 0.87 0.79
Inline graphic Inline graphic Inline graphic 80.43 72.43 87.26 0.88 0.80
Inline graphic Inline graphic Inline graphic 81.18 73.21 86.43 0.88 0.80
Inline graphic Inline graphic Inline graphic 81.31 74.24 87.34 0.89 0.81
Inline graphic Inline graphic Inline graphic 78.82 72.45 85.18 0.88 0.78
Inline graphic Inline graphic Inline graphic 77.10 71.22 84.17 0.87 0.78
Inline graphic Inline graphic Inline graphic 79.76 71.42 84.58 0.88 0.79
Inline graphic Inline graphic Inline graphic 78.87 70.80 86.45 0.87 0.78
Inline graphic Inline graphic Inline graphic 78.36 72.15 86.43 0.88 0.79
Inline graphic Inline graphic Inline graphic 79.41 74.81 87.02 0.89 0.80
Inline graphic Inline graphic Inline graphic Inline graphic 81.60 76.54 86.87 0.89 0.80
Inline graphic Inline graphic Inline graphic Inline graphic 82.11 76.77 87.12 0.90 0.81
Inline graphic Inline graphic Inline graphic Inline graphic 81.25 75.88 85.60 0.89 0.80
Inline graphic Inline graphic Inline graphic Inline graphic 80.78 74.63 85.34 0.88 0.80
Inline graphic Inline graphic Inline graphic Inline graphic 82.90 76.65 86.37 0.90 0.81
Inline graphic Inline graphic Inline graphic Inline graphic Inline graphic 83.21 78.02 88.39 0.91 0.81

Note:Inline graphicindicates whether to use this frequency band.

Among the single-frequency inputs, the Inline graphic band consistently delivered the most pronounced improvements. On CHB-MIT, Inline graphic exceeded the average of the remaining four bands by 5.53 percentage points in accuracy, 3.81 percentage points in sensitivity, 6.22 percentage points in specificity, and approximately 0.05 in AUC. Parallel gains were observed on TUH: 4.25, 7.36, 7.29 percentage points and approximately 0.05, respectively. These enhancements confirm that Inline graphic-band inputs most effectively boost sensitivity and specificity for cross-subject seizure detection, aligning with prior findings that link Inline graphic-band activity to seizure onset40–42.

Among all dual-band inputs, the (Inline graphic, Inline graphic) combination consistently outperforms the others. On CHB-MIT it achieves 80.43% accuracy, 73.21% sensitivity, 87.65% specificity and 0.89 AUC, surpassing every alternative pairing. A parallel pattern is observed on TUH, where (Inline graphic, Inline graphic) attains 79.63% accuracy, 72.15% sensitivity, 86.25% specificity and 0.88 AUC, again exceeding all competing dual-band inputs. These findings establish (Inline graphic, Inline graphic) fusion as the most effective two-band configuration for cross-subject seizure detection, corroborating prior evidence of strong (Inline graphic, Inline graphic) coupling43,44 and highlighting the complementary roles of Inline graphic oscillations in seizure onset, particularly in focal epilepsy45,46.

Tri-band ((Inline graphic, Inline graphic, Inline graphic), (Inline graphic, Inline graphic, Inline graphic), (Inline graphic, Inline graphic, Inline graphic),) and quad-band ((Inline graphic, Inline graphic, Inline graphic, Inline graphic), (Inline graphic, Inline graphic, Inline graphic, Inline graphic), (Inline graphic, Inline graphic, Inline graphic, Inline graphic)) ensembles achieve robust performance, confirming complementarity across high-, mid- and low-frequency components. Despite these gains, all multi-band combinations still trail the full five-band baseline in overall accuracy and AUC. Notably, on CHB-MIT the (Inline graphic, Inline graphic, Inline graphic, Inline graphic) quartet surpasses the full-band setup by 0.46 in sensitivity, likely because the Inline graphic band carries predominantly interictal information and attenuates ictal-related sensitivity47.

Overall, these ablation studies demonstrate that multi-band feature fusion significantly outperforms single-band input for cross-subject seizure detection. The complementary nature of different frequency bands enhances both sensitivity and generalizability. The model effectively leverages full-spectrum EEG information to achieve robust and accurate seizure detection across various subjects and datasets. These findings validate the necessity of incorporating multi-band EEG information into seizure detection frameworks and highlight the potential for further performance improvements through the optimization of band selection and fusion strategies. Future work will investigate patient-specific band selection to further optimize detection for individual seizure profiles.

Parameter tuning

As illustrated in Fig. 3, the impact of hyperparameters on model performance reveals clear trends. The highest F1-score of 0.84 was achieved with a learning rate of 0.001, batch size of 64, kernel size of 3, and 32 filters—marked as the peak in the visualization. This configuration significantly outperformed most settings with a higher learning rate (0.01), confirming that slower, more stable training leads to better generalization. The plot further shows that lower learning rates consistently yield higher scores across different batch sizes and kernel configurations, especially when combined with moderate filter counts.

Fig. 3.

Fig. 3

Hyperparameter impact on F1-score. The blue line highlights the optimal configuration.

The visualization highlights that small kernel sizes (3) and medium filter counts (32) achieve optimal performance, while larger kernels (5 or 7) and excessive filters (64) lead to performance drops, particularly at higher learning rates. Increasing filters from 16 to 32 generally improves results, but further expansion offers diminishing returns. Similarly, batch sizes of 64 and 128 perform comparably, with 64 slightly favored under optimal conditions. Overall, the parameter landscape peaks at a well-balanced configuration, emphasizing the importance of coordinated tuning for maximizing model effectiveness.

Comparisons with advanced models

The proposed PSD-LW-DCN model was evaluated on the CHB-MIT and TUSZ datasets against state-of-the-art baselines, including CNN-Self-Attention19, DCN36, DeepCNN37, ResNet-LSTM18, PANN17, StackedCNN15, EEGWaveNet16, and Transformer14, using metrics such as accuracy, sensitivity, specificity, AUC, and F1 score. The experimental results are presented in Table 6. On CHB-MIT, PSD-LW-DCN achieved the highest accuracy (85.84%), sensitivity (79.57%), AUC (0.94), and F1 score (0.84), outperforming the best prior method (ResNet-LSTM) by 2.10% in accuracy and significantly surpassing Transformer in AUC (+0.05) and F1 (+0.06). It also showed competitive specificity (92.12%). On TUSZ, the model attained the best accuracy (83.21%) and specificity (88.39%), with a high sensitivity of 78.02%, close to the best, and achieved the highest AUC (0.91) and F1 score (0.81), surpassing Transformer in both. These results demonstrate that PSD-LW-DCN consistently outperforms existing methods, offering superior overall performance and robustness in epileptic seizure detection.

Table 6.

Comparison of the proposed method with state-of-the-art techniques on two benchmark datasets.

Dataset Model Acc (%) Sen (%) Spe (%) AUC F1
CHB-MIT CNN-Self-Attention19 71.44 72.92 73.29 0.83 0.73
DCN36 79.24 73.65 85.75 0.88 0.77
DeepCNN37 77.14 71.25 82.55 0.85 0.74
Resnet-LSTM18 83.74 75.32 92.16 0.92 0.81
PANN17 71.63 78.39 64.83 0.83 0.72
StackedCNN15 79.20 74.36 84.01 0.87 0.76
EEGwaveNet16 78.73 78.25 79.14 0.87 0.77
Transformer14 81.22 76.24 86.22 0.89 0.78
HybirdCNN48 73.32 73.14 82.56 0.84 0.73
QFF-MLNet49 81.63 78.56 87.32 0.90 0.80
PSD-LW-DCN 85.84 Inline graphic 79.57 Inline graphic 92.12 0.94 Inline graphic 0.84 Inline graphic
TUSZ CNN-Self-Attention19 76.42 75.68 83.24 0.86 0.76
DCN36 80.12 77.09 84.69 0.89 0.78
DeepCNN37 79.14 75.25 82.13 0.83 0.72
Resnet-LSTM18 81.32 76.41 81.86 0.83 0.73
PANN17 74.29 75.89 82.73 0.82 0.71
StackedCNN15 75.17 73.17 77.18 0.83 0.73
EEGwaveNet16 70.22 74.89 65.57 0.79 0.70
Transformer14 79.29 78.28 80.31 0.88 0.77
HybirdCNN48 73.41 73.35 75.67 0.81 0.71
QFF-MLNet49 80.28 77.31 85.46 0.89 0.78
PSD-LW-DCN 83.21 Inline graphic 78.02 88.39 Inline graphic 0.91 Inline graphic 0.81 Inline graphic

Lightweight and deployability analysis

In clinical applications and edge-device deployment of electroencephalogram (EEG)-based epilepsy detection systems, model computational efficiency, parameter size, and inference speed are critical factors determining practical usability. This section presents a comparative analysis of the proposed PSD-LW-DCN method against mainstream deep learning models in terms of training overhead, model complexity, and inference performance, demonstrating its significant advantages in lightweight design and deployability while maintaining high accuracy.

To evaluate the practicality of these models in resource-constrained environments, we tested their inference efficiency on low-power devices. The results are shown in Table 7. The test platform was a laptop equipped with a GeForce GTX 960M GPU (2GB VRAM), an i7-4700MQ CPU, 4GB RAM, and running Ubuntu 14.04, simulating a typical edge computing scenario. The evaluation metric is the average inference time per EEG sample in milliseconds (ms/sample), where lower values indicate better real-time performance.

Table 7.

Comparison of the proposed method with state-of-the-art methods in terms of inference time.

HardWare Model Parameter Inference times on CHB (ms/sample) Inference times on TUSZ (ms/sample)

GPU: GeForce 960M(2G)

CPU: i7 4700MQ

Memory: 4GB

OS: Ubuntu 14.04

StackedCNN15 100,390 3.1 3.3
EEGwaveNet16 65,094 2.1 2.3
DeepCNN37 150,136 3.7 3.9
ResNet-LSTM18 24,617,154 6.63 7.13
CNN-Self-Attention19 83,567 2.9 3.1
Transformer14 281,666 4.06 4.13
PANN17 574,402 5.3 5.8
DCN36 264,752 3.93 3.98
HybirdCNN48 121,132 3.3 3.4
QFF-MLNet49 234,431 3.82 3.83
PSD-LW-DCN 61,218 1.9 2.1

Contemporary research frequently pursues performance through increasing model complexity, resulting in architectures like ResNet-LSTM and HybridCNN that suffer from significant parameter bloat (e.g., reaching 24.61 million parameters) and sluggish inference (>5ms/sample). Challenging this paradigm, PSD-LW-DCN is built upon the principle of minimalism for generalization. Instead of relying on brute-force depth, we employ holistic lightweight strategies to distill the architecture down to its essentials (61,218 parameters), achieving a 99.7% reduction compared to ResNet-LSTM. This shift in philosophy translates directly to operational efficiency: our model attains superior inference speeds of 1.9 ms/sample on the CHB dataset. While advanced methods like QFF-MLNet and PANN offer strong representational power, their latency renders them impractical for edge scenarios. In contrast, PSD-LW-DCN proves that high efficiency and robust generalization are not mutually exclusive, offering a viable solution for real-time deployment on resource-constrained devices.

In summary, the PSD-LW-DCN distinguishes itself not only by its compact model size and rapid inference speed but also by its significant clinical translational value. Its lightweight architecture directly addresses the real-world constraint of limited computational resources in edge devices, while its robust generalization capability ensures consistent performance across heterogeneous patient data. These attributes position PSD-LW-DCN as an ideal candidate for integration into mobile healthcare devices and wearable systems. Although large-scale deployment in clinical settings remains a direction for future work, our findings confirm that the model effectively bridges the gap between theoretical efficiency and practical, bedside utility.

Conclusion

The PSD-LW-DCN model has been proposed to enhance cross-subject seizure detection performance. By integrating PSD feature reconstruction, data augmentation, and balancing techniques, the model significantly improves detection accuracy. Interpretability analysis of PSD features provides insights into the model’s decision-making process. Extensive experiments on the CHB-MIT and TUSZ datasets demonstrate its effectiveness, achieving accuracies of 85.84% and 83.21%, respectively, with improvements of 5% and 3% over existing methods. The lightweight design ensures computational efficiency, making it suitable for real-time applications. Future work may focus on optimizing the architecture, exploring additional feature extraction techniques, and validating performance on larger datasets to further enhance robustness and applicability.

Author contributions

Peipei Gu and Ming Zhang: Conceptualization, Methodology, Formal analysis, Writing–original draft. Duo Chen and Naian Xiao: Supervision, editing, Writing–review & editing, Funding acquisition. Meiyan Xu, Jibin Shou and Jiayang Guo: Investigation, Data curation, Validation. All authors reviewed and approved the final version of the manuscript.

Funding

This work was supported by the National Natural Science Funds of China (62006100) and the Foundation and Cutting-Edge Technologies Research Program of Henan Province (CN) (262102210163).

Data availability

Data availability: This study of the use of CHB-MIT data sets and TUSZ data set is available at https://physionet.org/content/ chbmit/1.0.0/ and https://isip.piconepress.com/projects/nedc/html/tuh_eeg.

Declarations

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

These authors contributed equally to this work: Peipei Gu and Ming Zhang.

Contributor Information

Duo Chen, Email: 380013@njucm.edu.cn.

Naian Xiao, Email: wsxna@163.com.

References

  • 1.Fisher, R. S. et al. Instruction manual for the ILAE 2017 operational classification of seizure types. Epilepsia58, 531–542 (2017). [DOI] [PubMed] [Google Scholar]
  • 2.Van Mierlo, P., Höller, Y., Focke, N. K. & Vulliemoz, S. Network perspectives on epilepsy using EEG/MEG source connectivity. Front. Neurol.10, 721 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Kerr, W. T., McFarlane, K. N. & Figueiredo Pucci, G. The present and future of seizure detection, prediction, and forecasting with machine learning, including the future impact on clinical trials. Front. Neurol.15, 1425490 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Rasheed, K. et al. Machine learning for predicting epileptic seizures using eeg signals: A review. IEEE reviews in biomedical engineering14, 139–155 (2020). [DOI] [PubMed] [Google Scholar]
  • 5.Aggarwal, S. & Chugh, N. Review of machine learning techniques for EEG based brain computer interface. Arch. Comput. Methods Eng.29, 3001–3020 (2022). [Google Scholar]
  • 6.Kode, H., Elleithy, K. & Almazaydeh, L. Epileptic seizure detection in EEG signals using machine learning and deep learning techniques. IEEE Access12, 80657–80668 (2024). [Google Scholar]
  • 7.Ahmad, I. et al. An efficient feature selection and explainable classification method for EEG-based epileptic seizure detection. J. Inf. Secur. Appl.80, 103654 (2024). [Google Scholar]
  • 8.Divya, P. & Devi, B. A. Hybrid metaheuristic algorithm enhanced support vector machine for epileptic seizure detection. Biomed. Signal Process. Control.78, 103841 (2022). [Google Scholar]
  • 9.Wang, Q. et al. A hybrid SVM and kernel function-based sparse representation classification for automated epilepsy detection in EEG signals. Neurocomputing562, 126874 (2023). [Google Scholar]
  • 10.Al-Hadeethi, H., Abdulla, S., Diykh, M., Deo, R. C. & Green, J. H. Adaptive boost LS-SVM classification approach for time-series signal classification in epileptic seizure diagnosis applications. Expert Syst. Appl.161, 113676 (2020). [Google Scholar]
  • 11.Chen, W. et al. An automated detection of epileptic seizures EEG using CNN classifier based on feature fusion with high accuracy. BMC Med. Inform. Decis. Mak.23, 96 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Zhu, R., Pan, W.-X., Liu, J.-X. & Shang, J.-L. Epileptic seizure prediction via multidimensional transformer and recurrent neural network fusion. J. Transl. Med.22895. (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Tang, Y., Wu, Q., Mao, H. & Guo, L. Epileptic seizure detection based on path signature and Bi-LSTM network with attention mechanism. IEEE Trans. Neural Syst. Rehabil. Eng.32, 304–313 (2024). [DOI] [PubMed] [Google Scholar]
  • 14.Sun, Y. et al. Continuous seizure detection based on transformer and long-term iEEG. IEEE J. Biomed. Health Inform.26, 5418–5427 (2022). [DOI] [PubMed] [Google Scholar]
  • 15.Wang, X. et al. One dimensional convolutional neural networks for seizure onset detection using long-term scalp and intracranial EEG. Neurocomputing459, 212–222 (2021). [Google Scholar]
  • 16.Thuwajit, P. et al. Eegwavenet: Multiscale cnn-based spatiotemporal feature extraction for eeg seizure detection. IEEE Transactions on Industrial Informatics18, 5547–5557 (2021). [Google Scholar]
  • 17.Zhang, Z. et al. Cross-patient automatic epileptic seizure detection using patient-adversarial neural networks with spatio-temporal EEG augmentation. Biomed. Signal Process. Control89, 105664 (2024). [Google Scholar]
  • 18.Song, Y., Fan, C. & Mao, X. Optimization of epilepsy detection method based on dynamic EEG channel screening. Neural Netw.172, 106119 (2024). [DOI] [PubMed] [Google Scholar]
  • 19.Ru, Y., An, G., Wei, Z. & Chen, H. Epilepsy detection based on multi-head self-attention mechanism. PLoS One19, e0305166 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Peng, G., Nourani, M., Harvey, J. & Dave, H. Personalized EEG feature selection for low-complexity seizure monitoring. Int. J. Neural Syst.31, 2150018 (2021). [DOI] [PubMed] [Google Scholar]
  • 21.Liu, S., Wang, J., Li, S. & Cai, L. Epileptic seizure detection and prediction in EEGs using power spectra density parameterization. IEEE Trans Neural Syst Rehabil Eng31, 3884–3894 (2023). [DOI] [PubMed] [Google Scholar]
  • 22.Liu, J., Yang, Y., Li, F. & Luo, J. An epilepsy detection method based on multi-dimensional feature extraction and dual-branch hypergraph convolutional network. Front. Physiol.15, 1364880 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Majzoub, S., Fahmy, A., Sibai, F., Diab, M. & Mahmoud, S. Epilepsy detection with multi-channel EEG signals utilizing AlexNet. Circuits Syst. Signal Process.42, 6780–6797 (2023). [Google Scholar]
  • 24.Li, H., Liao, J., Wang, H., Chang’an, A. Z. & Yang, F. EEG power spectra parameterization and adaptive channel selection towards semi-supervised seizure prediction. Comput. Biol. Med.175, 108510 (2024). [DOI] [PubMed] [Google Scholar]
  • 25.Pan, Y., Dong, F., Yao, W., Meng, X. & Xu, Y. Empirical mode decomposition for deep learning-based epileptic seizure detection in few-shot scenario. IEEE Access12, 86583–86595 (2024). [Google Scholar]
  • 26.Saab, K., Dunnmon, J., Ré, C., Rubin, D. & Lee-Messer, C. Weak supervision as an efficient approach for automated seizure detection in electroencephalography. npj Digit. Med.3, 59 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Zhao, Y. et al. Multi-view cross-subject seizure detection with information bottleneck attribution. J. Neural Eng.19, 046011 (2022). [DOI] [PubMed] [Google Scholar]
  • 28.Zhou, J. et al. Both cross-patient and patient-specific seizure detection based on self-organizing fuzzy logic. Int. J. Neural Syst.32, 2250017 (2022). [DOI] [PubMed] [Google Scholar]
  • 29.Einizade, A., Mozafari, M., Sardouie, S. H., Nasiri, S. & Clifford, G. A deep learning-based method for automatic detection of epileptic seizure in a dataset with both generalized and focal seizure types. In 2020 IEEE Signal Processing in Medicine and Biology Symposium (SPMB), 1–6 (IEEE, 2020).
  • 30.Asif, U., Roy, S., Tang, J. & Harrer, S. Seizurenet: Multi-spectral deep feature learning for seizure type classification. In Machine Learning in Clinical Neuroimaging and Radiogenomics in Neuro-oncology: Third International Workshop, MLCN 2020, and Second International Workshop, RNO-AI 2020, Held in Conjunction with MICCAI 2020, Lima, Peru, October 4–8, 2020, Proceedings 3, 77–87 (Springer, 2020).
  • 31.Guttag, J. CHB-MIT Scalp EEG Database, 10.13026/C2K01R (2010).
  • 32.Harati, A. et al. The tuh eeg corpus: A big data resource for automated eeg interpretation. In 2014 IEEE signal processing in medicine and biology symposium (SPMB), 1–5 (IEEE, 2014).
  • 33.Shyu, K.-K., Huang, S.-C., Lee, L.-H. & Lee, P.-L. Less parameterization inception-based end to end CNN model for EEG seizure detection. IEEE Access11, 49172–49182 (2023). [Google Scholar]
  • 34.Dong, X. et al. Deep learning based automatic seizure prediction with EEG time-frequency representation. Biomed. Signal Process. Control95, 106447 (2024). [Google Scholar]
  • 35.Dong, C., Sun, D., Zhang, Z. & Luo, B. EEG-based patient-specific seizure prediction based on spatial-temporal hypergraph attention transformer. Biomed. Signal Process. Control100, 107075 (2025). [Google Scholar]
  • 36.Schirrmeister, R. T. et al. Deep learning with convolutional neural networks for EEG decoding and visualization. Hum. Brain Mapp.38, 5391–5420 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H. & Adeli, H. Deep convolutional neural network for the automated detection and diagnosis of seizure using EEG signals. Comput. Biol. Med.100, 270–278 (2018). [DOI] [PubMed] [Google Scholar]
  • 38.Prieto, G. A. The multitaper spectrum analysis package in Python. Seismol. Res. Lett.93, 1922–1929 (2022). [Google Scholar]
  • 39.Dan, J. et al. Szcore: Seizure community open-source research evaluation framework for the validation of electroencephalography-based automated seizure detection algorithms. Epilepsia10.1111/epi.18113 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Baumgartner, C. et al. Role of specific interictal and ictal EEG onset patterns. Epilepsy Behav.164, 110298 (2025). [DOI] [PubMed] [Google Scholar]
  • 41.Latreille, V. et al. Oscillatory and nonoscillatory sleep electroencephalographic biomarkers of the epileptic network. Epilepsia65, 3038–3051 (2024). [DOI] [PubMed] [Google Scholar]
  • 42.Qiu, C. et al. Differences and potential mechanisms of theta oscillation and temporoparietal and temporal-central networks in temporal lobe epilepsy patients with unilateral hippocampal sclerosis. Acta Epileptol.6, 26 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Liu, X., Han, F., Fu, R., Wang, Q. & Luan, G. Epileptogenic zone location of temporal lobe epilepsy by cross-frequency coupling analysis. Front. Neurol.12, 764821 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Tenney, J. R., Williamson, B. J. & Kadis, D. S. Cross-frequency coupling in childhood absence epilepsy. Brain Connect.12, 489–496 (2022). [DOI] [PubMed] [Google Scholar]
  • 45.Villa, A. E. & Tetko, I. V. Cross-frequency coupling in mesiotemporal EEG recordings of epileptic patients. J. Physiol. Paris104, 197–202 (2010). [DOI] [PubMed] [Google Scholar]
  • 46.Zhang, J. et al. Resting-state MEG source space network metrics associated with the duration of temporal lobe epilepsy. Brain Topogr.34, 731–744 (2021). [DOI] [PubMed] [Google Scholar]
  • 47.Pyrzowski, J., Siemiński, M., Sarnowska, A., Jedrzejczak, J. & Nyka, W. M. Interval analysis of interictal EEG: Pathology of the alpha rhythm in focal epilepsy. Sci. Rep.5, 16230 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Esmaeilpour, A., Tabarestani, S. S. & Niazi, A. Deep learning-based seizure prediction using EEG signals: A comparative analysis of classification methods on the CHB-MIT dataset. Eng. Rep.6, e12918 (2024). [Google Scholar]
  • 49.Jayanthi, V. & Sivakumar, S. Quantum inspired wavelet and Fourier feature fusion for EEG based epilepsy and seizure detection. Sci. Rep.10.1038/s41598-025-31219-3 (2026). [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Data availability: This study of the use of CHB-MIT data sets and TUSZ data set is available at https://physionet.org/content/ chbmit/1.0.0/ and https://isip.piconepress.com/projects/nedc/html/tuh_eeg.