Skip to main content
REC: Interventional Cardiology logoLink to REC: Interventional Cardiology
. 2025 Jul 8;8(1):8–16. doi: 10.24875/RECICE.M25000527

Drug-coated balloons vs drug-eluting stents for the treatment of large native coronary artery disease. Meta-analysis of randomized controlled trials

Balón farmacoactivo frente a stent farmacoactivo para el tratamiento de la enfermedad coronaria de vaso grande. Metanálisis de ensayos clínicos aleatorizados

José Antonio Sorolla Romero a,◊, Laura Novelli b,◊, Jorge Llau García a, Sara Huélamo Montoro a, Pablo Rubio c, José Luis Díez Gil a,d, Luis Martínez-Dolz a,d, Ignacio J Amat Santos d,e, Bernardo Cortese f,g, Fernando Alfonso d,h, Hector M Garcia-Garcia c, Jorge Sanz-Sánchez a,d,*
PMCID: PMC13137348  PMID: 42087868

ABSTRACT

Introduction and objectives:

To compare the effects of drug-coated balloon (DCB) vs drug-eluting stent (DES) in patients presenting with de novo large vessel coronary artery disease (CAD).

Methods:

We conducted a systematic research of randomized controlled trials comparing DCB vs DES in patients with de novo large vessel CAD. Data were pooled by meta-analysis using a random-effects model. The prespecified primary endpoint was target lesion revascularization (TLR).

Results:

A total of 7 trials enrolling 2961 patients were included. The use of DCB vs DES was associated with a similar risk of TLR (OR, 1.21; 95%CI, 0.44-3.30; I2 = 48%), all-cause mortality (OR, 1.56; 95%CI, 0.942.57; I2 = 0%), cardiac death (OR, 1.65; 95%CI, 0.90-3.05; I2 = 0%), myocardial infarction (OR, 0.97; 95%CI, 0.58-1.61; I2 = 0%), major adverse cardiovascular adverse (OR, 1.19; 95%CI, 0.74-1.90; I2 = 13.5%) and late lumen loss (standardized mean difference [SMD], −0.35; 95%CI, −0.74 to 0.04; I2 = 81.4%). However, the DCB was associated with a higher risk of target vessel revascularization (OR, 2.47; 95%CI, 1.52-4.03; I2 = 0%) and smaller minimal lumen diameter during late follow-up (SMD, −0.36; 95%CI, −0.56 to −0.15; I2 = 34.5%). Nevertheless, prediction intervals included the value of no difference for both outcomes.

Conclusions:

In patients with de novo large vessel CAD the use of DCB vs DES is associated with a similar risk of TLR. However, the DES achieves better late angiographic results.

Keywords: Drug-coated balloon, Drug-eluting stent, Coronary artery disease


Abbreviations

CAD:

coronary artery disease.

DCB:

drug-coated balloon.

DES:

drug-eluting stent.

MI:

myocardial infarction.

MLD:

minimum lumen diameter.

TLR:

target lesion revascularization.

SEE RELATED CONTENT: https://doi.org/10.24875/RECICE.M25000542

INTRODUCTION

Drug-eluting stents (DES) remain the standard of treatment for patients undergoing percutaneous coronary intervention (PCI).1,2 However, DES are associated with a gradually and permanent increased risk of adverse events, particularly due to late stent thrombosis and in-stent restenosis, with a 2% incidence rate per year with no plateau observed.1 This risk is even higher when complex and long lesions are treated.3 In recent years, drug-coated balloons (DCB) have emerged as a potential alternative treatment option to DES. Following adequate lesion preparation, unlike traditional stents, DCBs can release an antiproliferative drug into the vessel wall without leaving behind a permanent metal scaffold. Notably, permanent scaffolding can distort and constrain the coronary vessel, thus impairing vasomotion and adaptive remodelling, while also promoting chronic inflammation.4 DCB-PCI is a well-established treatment for in-stent restenosis and small-vessel coronary artery disease (CAD).5,6 However, its role in de novo large vessel CAD remains controversial. In a recent randomized clinical trial (RCT) with patients undergoing de novo CAD revascularization, a strategy of DCB-PCI did not achieve non-inferiority vs DES in terms of device-oriented composite endpoint driven by higher rates of target lesion revascularization (TLR).7 Contrary to prior published research, our findings did not support similar clinical outcomes for DCB vs DES in patients with de novo large vessel CAD.8,9 A recent meta-analysis of 15 studies compared DCB-PCI or hybrid angioplasty vs DES-PCI in patients with vessels > 2.75 mm in diameter showing no significant differences in the clinical endpoints of TLR, cardiac death, and MI.10 However, 14 of the 15 included studies were non-RCT, and the recent previously reported RCT was not included. Nevertheless, individual non-inferiority studies often lack the statistical power needed to definitively compare these technologies, underscoring the need for a systematic appraisal of treatment effects and evidence quality. Therefore, we conducted a systematic review and meta-analysis of available RCT to provide a comprehensive and quantitative assessment of evidence on the efficacy of DCB vs the current-generation DES in de novo large vessel CAD in terms of adverse events at longest available follow-up.

METHODS

Search strategy and selection criteria

We conducted a meta-analysis of RCT according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2009 guidelines.11 Two reviewers independently identified the relevant studies through an electronic search across the MEDLINE and Embase databases (from inception to October 2024). In addition, we employed backward snowballing (eg, reference review from identified articles and pertinent reviews). No language, publication date or publication status restrictions were imposed. This study is registered with PROSPERO and the search strategy is available in the supplementary data.

Study selection

Two reviewers independently assessed trial eligibility based on titles, abstracts, and full-text reports. Discrepancies in study selection were discussed and resolved with a third investigator. Eligible studies needed to meet the following pre-specified criteria: a) RCT comparing PCI with DCB and PCI with DES; b) study population including patients with de novo large vessel CAD (eg, defined as vessel diameter ≥ 2.5 mm);12 c) availability of clinical outcome data (without restriction as to follow-up time). Exclusion criteria were a) lack of a randomized design; b) studies including patients undergoing treatment for in-stent restenosis; c) studies including patients with de novo small vessel CAD; d) lack of any clinical outcome data.

A reference vessel diameter ≥ 2.5 mm was established as the cut-off value to define large vessel based on a recent proposed standardized definition.12

Data extraction

Three investigators (J. Llau García, S. Huélamo Montoro and J. A. Sorolla Romero) independently assessed studies for possible inclusion, with the senior investigator (J. Sanz-Sánchez) resolving discrepancies. Non-relevant articles were excluded based on title and abstract. The same investigators independently extracted data on study design, measurements, patient characteristics, and outcomes using a standardized data-extraction form. Data extraction conflicts were discussed and resolved with the senior investigator.

Data on authors, year of publication, inclusion and exclusion criteria, sample size, patients’ baseline patients, endpoint definitions, effect estimates, and follow-up time were collected.

Endpoints

The prespecified primary endpoint was TLR. Secondary clinical endpoints were all-cause mortality, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR) and major adverse cardiovascular events (MACE). Secondary angiographic endpoints were minimum lumen diameter (MLD) and late lumen loss (LLL). Each endpoint was assessed according to the definitions reported in the original study protocols, as summarized in table 1 of the supplementary data. All the endpoints were assessed at the maximum follow-up available.

Risk of bias

The risk of bias in each study was assessed using the revised Cochrane risk of bias tool (RoB 2.0).11 Three investigators (J. Llau García, S. Huélamo Montoro and J. A. Sorolla Romero) independently assessed 5 domains of bias in RCT: a) randomization process, b) deviations from intended interventions, c) missing outcome data, d) outcome measurement, and e) selection of reported results (table 2 of the supplementary data).

Statistical analysis

Odds ratios (OR) and 95% confidence intervals (95%CI) were calculated using the DerSimonian and Laird random-effects model, with the estimate of heterogeneity being obtained from the Mantel-Haenszel method. The presence of heterogeneity among studies was evaluated with the Cochran Q chi-square test, with P ≤ .10 being considered of statistical significance, and using the I2 test to evaluate inconsistency. A value of 0% indicates no observed heterogeneity, and values of ≤ 25%, ≤ 50%, > 50% indicate low, moderate, and high heterogeneity, respectively. Prediction intervals (95%) in addition to conventional 95%CI around ORs were calculated to assess residual uncertainty. Publication bias and the small study effect were assessed for all outcomes, using funnel plots. The presence of publication bias was investigated using Harbord and Egger tests and visual estimation with funnel plots. We performed a sensitivity analysis by removing one study at a time to confirm that the findings, when compared with DES, were not driven by any single study. To account for different lengths of follow-up across studies, another sensitivity analysis was performed using the Poisson regression model with random intervention effects to calculate inverse-variance weighted averages of study-specific log stratified incidence rate ratios (IRRs). Results were displayed as IRRs, which are exponential ratios of the regression model. Additionally, random-effect meta-regression analyses were performed to assess the impact of the following variables on treatment effect with respect to the primary endpoint: eg, percentage of patients with acute coronary syndrome (ACS), percentage of patients with diabetes mellitus, mean reference vessel diameter and follow-up duration. The statistical level of significance was 2-tailed P < .05. Stata version 18.0 (StataCorp LP, College Station, United States), was used for statistical analyses.

RESULTS

Search results

Figure 1 illustrates the PRISMA study search and selection process. A total of 7 RCT were identified and included in this analysis. The main features of included studies are shown in table 1.

Figure 1. Flow diagram of the search for studies included in the meta-analysis according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Statement.

Figure 1

Table 1. Main features of included studies.

Study Year of publication No. of patients Type of Device Reference vessel diameter (mean ± SD) (mm) Multicenter Clinical follow up (months) Angiographic follow-up (months)
DCB DES
REC-CAGEFREE I7 2024 1133 1139 Paclitaxel-DCB Sirolimus-DES 3.00 ± 0.55 YES 24 NO
Nishiyama et al.13 2016 30 30 Paclitaxel-DCB
Everolimus-DES
2.80 ± 0.63 NO 8 8
Xue Yu et al.8 2022 85 85 Paclitaxel-DCB
Everolimus-DES
2.89 ± 0.33 NO 12 9
REVELATION9 2019 60 60 Paclitaxel-DCB
Sirolimus and everolimus DES
3.24 ± 0.50 NO 24 9
Gobic et al.15 2017 38 37 Paclitaxel-DCB
Sirolimus-DES
> 2.50 NO 6 6
Hao et al.16 2021 38 42 Paclitaxel-DCB
NA
> 2.50 NO 12 12
Wang et al.14 2022 92 92 Paclitaxel-DCB
Sirolimus-DES
3.37 ± 0.52 NO 12 9

DCB, drug-coated balloon; DES, drug-eluting stent; NA, not available.

All studies had a non-inferiority design. A clinical primary endpoint was selected in 1 study,7 and an invasive functional endpoint was selected in another trial,9 while angiographic primary endpoints were prespecified in the remaining studies.8,13-16 The mean clinical and angiographic follow-up were 21.5 months and 8.9 months respectively. A total of 4 studies were conducted in the context of ACS9,14-17 and 1 study in the context of chronic coronary syndrome (CCS).13 Finally, 2 studies enrolled both ACS and CCS patients.7,8 A total of 3 trials enrolled patients treated with second-generation DES (Firebird 2.0 [Microport, China], Xience Xpedition [Abbott Vascular, United States], Orsiro [Biotronik, Germany]),7,9,13 and 2 studies enrolled patients treated with third-generation DES (Biomine [Meril Life Sciences, India], Cordimax [Rientech, China]).14,15 One trial enrolled patients treated with second and third-generation DES (Xience Xpedition [Abbott Vascular, United States], Resolute Integrity, [Medtronic, United States], Firehawk, [MicroPort, China]).8 All studies included patients who underwent paclitaxel-DCB-PCI ([Pantera Lux, Biotronik, Germany],9,14 [SeQuent Please, B Braun, Germany],7,8,13,15 [Bingo DCB, Yinyi Biotech,China]),16 and none with sirolimus-DCB-PCI.

Baseline characteristics

A total of 2961 patients were included, 1476 of whom received DCB and 1485, DES for de novo large vessel CAD. The patients main baseline characteristics are shown in table 2.

Table 2. Baseline clinical characteristics of included patients.

Study Age (years) Male (%) Diabetes (%) Smoking (%) Hypertension (%) LVEF (%) Clinical Presentation (CCS/ACS) (%) Multivessel (%) Complex lesion (%)
REC-CAGEFREE I7 62 69.3 27.3 45 60.1 60 44.9/55.3 4.8 0
Nishiyama et al.13 69 73.3 41.6 60 83.3 NA 0/100 NA 36
Xue Yu et al.8 63.3 69.3 24.1 54 63.9 > 40 11.1/88.9 84 44.1
REVELATION9 57 87 10 60 31 57.6 0/100 71.6 N/A
Gobic et al.15 57.4 87 10 49.5 33.4 50.2 0/100 NA N/A
Hao et al.16 57.5 78.5 31.5 29.5 24 46 0/100 NA N/A
Wang et al.14 49.5 93.5 81.6 81.5 71.8 NA 0/100 NA N/A

ACS, acute coronary syndrome; CCS, chronic coronary syndrome; NA, not available.

Publication bias and asymmetry

Funnel-plot distributions of the pre-specified outcomes indicate absence of publication bias for all the outcomes (figures 1-8 of the supplementary data).

Risk of bias assessment

Table 2 of the supplementary data illustrates the results of the risk of bias assessment with the RoB 2.0 tool. One trial was considered at low overall risk of bias,7 5 raised some concerns8,9,13,14,16 and 1 presented a high overall risk of bias.15

Outcomes

Clinical outcomes

DCB use compared with DES was associated with a similar risk of TLR (OR, 1.21; 95%CI, 0.44-3.30; I2 = 48%), all-cause mortality (OR, 1.56; 95%CI, 0.94- 2.57; I2 = 0%), cardiac death (OR, 1.65; 95%CI, 0.90-3.05; I2 = 0%), MI (OR, 0.97; 95%CI, 0.58-1.61; I2 = 0%) and MACE (OR, 1.19; 95%CI, 0.74-1.90; I2 = 13.5%). However, DCB was associated with a higher risk of TVR (OR, 2.47; 95%CI, 1.52- 4.03; I2 = 0%) (figure 2, figure 3 and figures 9-10 of the supplementary data).

Figure 2. Forest plot reporting trial-specific and summary ORs with 95%CIs for the endpoint of A) target lesion revascularization; B) all-cause mortality; C) myocardial infarction; D) MACE. 95%CI, 95% confidence interval; DCB, drug-coated balloon; DES, drug-eluting stents; MACE, major adverse cardiovascular events; OR, odds ratio. References: REC-Cagefree I.,7 Nishiyama et al.,13 Xue Yu et al.,8 REVELATION,9 Hao et al.,16 Wang et al.,14 and Gobic et al.15.

Figure 2

Figure 3. Central Illustration. DCB, drug-coated balloon; DES, drug-eluting stent; RCT, randomized clinical trial; TVR, target vessel revascularization. References: REC-Cagefree I.,7 Nishiyama et al.,13 Xue Yu et al.,8 REVELATION,9 Hao et al.,16 and Wang et al.14.

Figure 3

Angiographic outcomes

Compared with DES, DCB use yielded significant smaller MLD (SMD, −0.36; 95%CI, −0.56 to −0.15; I2 = 34.5%) and similar risk of LLL (SMD, −0.35; 95%CI, −0.74 to 0.04; I2 = 81.4%) at follow-up (figure 4).

Figure 4. Forest plot reporting trial-specific and summary ORs with 95%CIs for the endpoint of A: minimum lumen diameter, and B: late-lumen loss. 95%CI, 95% confidence interval; DCB, drug-coated balloon; DES, drug-eluting stents; MACE, major adverse cardiovascular events; MLD, minimum lumen diameter; SMD, standardized mean difference; OR, odds ratio. References: Nishiyama et al.,13 Xue Yu et al.,8 REVELATION,9 Gobic et al.,15 Hao et al.,16 and Wang et al.14.

Figure 4

Prediction intervals were consistent with CI for all the outcomes except for TVR and MLD, which included the value of no difference.

Sensitivity analysis

A leave-one-out pooled analysis by iteratively removing one study at a time was performed for all endpoints. Treatment effects were consistent with the main analysis for TLR, all-cause mortality, cardiac death, MI and MLD. The risk of TVR was no longer significantly higher among patients undergoing DCB when removing the CAGEFREE I trial,7 and the risk of LLL was significantly lower among patients undergoing DCB-PCI when removing the REVELATION trial.9 However, an increased risk of MACE was observed among patients undergoing DCB-PCI when removing the study by Xue Yu et al.18 (tables 3-10 of the supplementary data). A sensitivity analysis using estimated IRRs was performed to account for varying follow-up lengths, confirming that our main analysis findings remained unchanged (table 11 of the supplementary data).

Random effect meta-regression analysis found no significant impact of the proportion of patients presenting with ACS (P = .882), diabetes mellitus (P = .641), mean reference vessel diameter (P = .985) and follow-up duration (P = .951) on treatment effect with respect to the primary endpoint.

DISCUSSION

This meta-analysis provides a comprehensive and updated quantitative analysis of available evidence on the comparison of DCB vs DES in de novo large vessel CAD, including data from 2961 patients enrolled in 7 RCT. The main findings of the study are:

a) The use of DCB was associated with a similar risk of clinical events vs DES except for TVR. However, data for this outcome was only available in 3 of the 7 included studies and the increased risk in patients undergoing DCB-PCI was not significant when the CAGEFREE I trial was removed. In addition, prediction intervals were not consistent with the CI. Therefore, the results of this outcome should be interpreted with caution.

b) The effect of DCB on the risk of TLR was not affected by the proportion of patients presenting with ACS or diabetes, as well as the mean reference vessel diameter or follow-up duration as assessed by meta-regression analysis.

c) DCB was associated with lower MLD at angiographic follow-up, but with similar LLL vs DES.

DES are the standard of treatment for patients undergoing PCI. However, complications such as stent thrombosis and in-stent restenosis still occur with rates estimated at 0.7-1% and 5-10% at the 10-year follow-up respectively.19,20 Therefore, in recent years there has been a growing concern for developing strategies to reduce stent-related adverse events. In this context, DCBs have emerged as a potential treatment alternative based on a “leaving nothing behind” strategy. Nevertheless, data of patients presenting with de novo large CAD is scarce and conflicting. The CAGEFREE I is the only available clinically powered RCT that included 2272 patients undergoing de novo non-complex CAD revascularization across 40 centers in China. A strategy of DCB-PCI did not achieve non-inferiority vs DES in terms of device-oriented composite endpoint driven by higher rates of TLR in the DCB-PCI group (3.1% vs 1.2%, P = .002). On the other hand, in single-center RCT conducted by Nishiyama et al. with 60 patients with CCS undergoing elective PCI a trend toward lower rates of TLR in the DCB-PCI group (0% vs 6.1%, P = .193) was shown at the 8-mont follow-up.13 Similarly, in a RCT including 170 patients undergoing PCI for de novo large CAD lower rates of TLR at the 12-month follow-up were found in patients undergoing DCB-PCI (1.6% vs 3.4%, P = .306).14 In our analysis when pooling data from all available RCT, the risk of TLR was similar among patients undergoing DCB-PCI or DES-PCI. Notably, since this result was obtained with a moderate heterogeneity (I2 ≈ 50%), it should be interpreted with caution regarding its general applicability. These findings remained unvaried at the leave-one-out analysis. In addition, prediction intervals were consistent with CI around ORs showing lack of residual uncertainty. Previous studies have shown that in-stent restenosis after DES is not a benign phenomenon, presenting as an ACS in about 70% of the cases, with 5-10% of these resulting in MI.21 We could speculate that the lack of permanent scaffold with DCB vs DES may predispose to a less aggressive pattern of restenosis and not increase the risk of thrombotic vessel closure beyond 3 months when vessel healing after DCB-PCI has occurred.22

Notably, 5 of the 7 studies included in this meta-analysis enrolled patients presenting with ACS. A total of 34% of the patients included in the CAGEFREE study presented with ACS, with 16% being STEMI cases.7 Four other studies only included STEMI patients.7,9,14-16 Although the performance of DCB in the STEMI scenario is unknown, its use in clinical practice is increasing.23 Culprit lesion plaques in STEMI patients are usually soft and adequate plaque modification can be easily achieved through DCB-PCI (< 30% residual stenosis and low grade of dissection).23 Moreover, the ruptured lipid rich plaque can potentially be an ideal reservoir for effective paclitaxel uptake.24 On the other hand, DCBs carry specific risks for STEMI patients, such as acute recoil and culprit lesion closure, because they don’t provide vessel scaffolding.

In our study, the proportion of patients presenting with ACS had no impact on treatment effects on the meta-regression analysis. Nevertheless, further RCT with adequate sample size are needed to obtain more solid evidence in this field. Of note, complex lesions (eg, severe calcification and bifurcations with planned two-stent technique) were excluded from the studies that included patients presenting with CCS.7,8 Therefore, our findings might not be generalized to this population.

The better angiographic surrogate outcomes with DES-PCI vs DCB-PCI found in our meta-analysis after pooling data from 6 studies can be explained by the absence of a metal scaffold to expand the vessel lumen and the acute recoil following balloon angioplasty. This justifies the lower MLD achieved after DCB-PCI vs DES-PCI. While our analysis did not show significant differences regarding LLL during follow-up, the value of LLL was lower among patients undergoing DCB-PCI when excluding the REVELATION trial.9,17 This study showed extremely low LLL in both DCB and DES groups vs other available evidence from RCT.15,16 The presence of positive vessel remodeling with a late lumen enlargement after the use of DCB evaluated by intracoronary imaging modalities has been evidenced in multiple studies, and seems to be associated with small vessel disease, fibrous and layered plaques and a post-PCI medial dissection arc > 90°.25,26,27 However, evidence of this phenomenon in patients with large vessel CAD is less known.22 It should, therefore, be noted that all studies in this meta-analysis used paclitaxel-DCB. While the evidence comparing sirolimus and paclitaxel-DCB is scarce, 2 recent RCT have shown better angiographic results with the lipophilic component. In the first one, with 121 patients with the novo small vessel CAD, sirolimus-DCB failed to achieve non-inferiority for net-lumen gain at 6 months.28 In the second study, with 70 patients, the 2 devices showed similar results of LLL at 6 months, although patients treated with paclitaxel-DCB had more frequent late luminal enlargement.29 Due to the small sample size and although there is not enough evidence to evaluate differences across clinical endpoints, we cannot assume that there is a class effect across all DCBs. There are larger ongoing RCT to evaluate the outcomes of sirolimus DCB vs DES in large vessels that will provide evidence in this field.30,31

Limitations

The results of our investigation should be interpreted in light of some limitations. First, this is a study-level meta-analysis providing average treatment effects. The lack of patient-level data from the included studies prevents us from assessing the impact of baseline clinical, angiographic and procedural characteristics on treatment effects. Second, minor differences in definition were present for some endpoints (eg, MACE), limiting the reliability of effect estimates. Third, one study which accounted for approximately 75% of all patients included did not included angiographic follow-up,7 thus limiting the evaluation of DCB and DES on angiographic outcomes. Fourth, the clinical follow-up varied from 6 to 24 months. Ideally, outcomes such as TLR should be compared at uniform follow-up across studies (eg, at 1 year), which was not consistently possible in the current analysis. Nonetheless, these differences in follow-up duration were accounted with the IRRs, as detailed in the Methods section. However, longer follow-ups are needed to establish the safety and efficacy profile of DCB vs DES throughout time. Fifth, the definition of large vessel is inconsistent across trials, which might be a source of bias. Finally, the limited number of studies and patients, and the small event rate for some endpoints, such as all-cause mortality may reduce the power for detecting significant differences across groups.

CONCLUSIONS

This meta-analysis provides the most updated quantitative evidence on the use of DCB vs DES for the treatment of de novo large vessel CAD in both CCS and ACS. DCB-PCI is associated with similar TLR and LLL at mid-term follow-up representing an appealing treatment option for patients with large vessel CAD.

ETHICAL CONSIDERATIONS

Ethics approval was deemed unnecesary for this meta-analysis as all data were collected and synthesized from previous studies. Additionally, no informed consent was required as there were no patients involved in our work. The meta-analysis of RCT was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2009 guidelines. We confirm that sex/gender biases have been taken into consideration.

STATEMENT ON THE USE OF ARTIFICIAL INTELLIGENCE

No artificial intelligence has been used in the preparation of this article.

AUTHORS’ CONTRIBUTIONS

J. Llau García, S. Huelamo Montoro and J.A. Sorolla Romero par- ticipated in literature research and study selection. J.A. Sorolla Romero, L. Novelli and J. Sanz Sánchez contributed to the conception, design, drafting and revision of the article. P. Rubio, J.L. Díez Gil, L. Martínez-Dolz, I.J. Amat Santos, B. Cortese, F. Alfonso, and H.M. Garcia-Garcia contributed to the critical revision of the in- tellectual content of the article.

WHAT IS KNOWN ABOUT THE TOPIC?

  • – DCB are a well-established treatment for patients with small-vessel CAD.

  • – Available published evidence of patients with de novo large vessel CAD is scarce and shows conflicting results.

WHAT DOES THIS STUDY ADD?

  • – In this meta-analysis including data from 2961 patients enrolled in 7 RCT, DCB showed similar risk of clinical events at follow-up vs DES in the treatment of de novo large vessel CAD.

  • – The use of DCB might be considered as an alternative option to DES in patients undergoing PCI for non-complex de novo large vessel CAD.

SUPPLEMENTARY DATA

Supplementary data

Supplementary material associated with this article.

Funding Statement

None declared.

REFERENCES

  • 1.Neumann FJ, Sousa-Uva M, Ahlsson A, et al. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. 2019;40:87–165. doi: 10.1093/eurheartj/ehy394. [DOI] [PubMed] [Google Scholar]
  • 2.Lawton JS, Tamis-Holland JE, Bangalore S, et al. 2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: Executive Summary:A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2022;145:e4–e17. doi: 10.1161/CIR.0000000000001039. [DOI] [PubMed] [Google Scholar]
  • 3.Kong MG, Han JK, Kang JH, et al. Clinical outcomes of long stenting in the drug-eluting stent era:patient-level pooled analysis from the GRAND-DES registry. EuroIntervention J Eur Collab Work Group Interv Cardiol Eur Soc Cardiol. 2021;16:1318–1325. doi: 10.4244/EIJ-D-19-00296. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Kawai T, Watanabe T, Yamada T, et al. Coronary vasomotion after treatment with drug-coated balloons or drug-eluting stents:a prospective, open-label, single-centre randomised trial. EuroIntervention. 2022;18:e140–e148. doi: 10.4244/EIJ-D-21-00636. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Jeger RV, Eccleshall S, Wan Ahmad WA, et al. Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group. JACC Cardiovasc Interv. 2020;13:1391–1402. doi: 10.1016/j.jcin.2020.02.043. [DOI] [PubMed] [Google Scholar]
  • 6.Sanz Sánchez J, Chiarito M, Cortese B, et al. Drug-Coated balloons vs drug-eluting stents for the treatment of small coronary artery disease: A meta-analysis of randomized trials. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv. 2021;98:66–75. doi: 10.1002/ccd.29111. [DOI] [PubMed] [Google Scholar]
  • 7.Gao C, He X, Ouyang F, et al. Drug-coated balloon angioplasty with rescue stenting versus intended stenting for the treatment of patients with de novo coronary artery lesions (REC-CAGEFREE I): an open-label, randomised, non-inferiority trial. Lancet Lond Engl. 2024;404:1040–1050. doi: 10.1016/S0140-6736(24)01594-0. [DOI] [PubMed] [Google Scholar]
  • 8.Yu X, Wang X, Ji F, et al. A Non-inferiority, Randomized Clinical Trial Comparing Paclitaxel-Coated Balloon Versus New-Generation Drug-Eluting Stents on Angiographic Outcomes for Coronary De Novo Lesions. Cardiovasc Drugs Ther. 2022;36:655–664. doi: 10.1007/s10557-021-07172-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Vos NS, Fagel ND, Amoroso G, et al. Paclitaxel-Coated Balloon Angioplasty Versus Drug-Eluting Stent in Acute Myocardial Infarction: The REVELATION Randomized Trial. JACC Cardiovasc Interv. 2019;12:1691–1699. doi: 10.1016/j.jcin.2019.04.016. [DOI] [PubMed] [Google Scholar]
  • 10.Gobbi C, Giangiacomi F, Merinopoulos I, et al. Drug coated balloon angioplasty for de novo coronary lesions in large vessels:a systematic review and meta-analysis. Sci Rep. 2025;15:4921. doi: 10.1038/s41598-025-85734-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009;339:b2535. doi: 10.1136/bmj.b2535. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Sanz-Sánchez J, Chiarito M, Gill GS, et al. Small Vessel Coronary Artery Disease:Rationale for Standardized Definition and Critical Appraisal of the Literature. J Soc Cardiovasc Angiogr Interv. 2022;1:100403. doi: 10.1016/j.jscai.2022.100403. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Nishiyama N, Komatsu T, Kuroyanagi T, et al. Clinical value of drug-coated balloon angioplasty for de novo lesions in patients with coronary artery disease. Int J Cardiol. 2016;222:113–118. doi: 10.1016/j.ijcard.2016.07.156. [DOI] [PubMed] [Google Scholar]
  • 14.Wang Z, Yin Y, Li J, et al. New Ultrasound-Controlled Paclitaxel Releasing Balloon vs. Asymmetric Drug-Eluting Stent in Primary ST-Segment Elevation Myocardial Infarction-A Prospective Randomized Trial. Circ J Off J Jpn Circ Soc. 2022;86:642–650. doi: 10.1253/circj.CJ-21-0315. [DOI] [PubMed] [Google Scholar]
  • 15.Gobić D, Tomulić V, Lulić D, et al. Drug-Coated Balloon Versus Drug-Eluting Stent in Primary Percutaneous Coronary Intervention:A Feasibility Study. Am J Med Sci. 2017;354:553–560. doi: 10.1016/j.amjms.2017.07.005. [DOI] [PubMed] [Google Scholar]
  • 16.Hao X, Huang D, Wang Z, Zhang J, Liu H, Lu Y. Study on the safety and effectiveness of drug-coated balloons in patients with acute myocardial infarction. J Cardiothorac Surg. 2021;16:178. doi: 10.1186/s13019-021-01525-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Niehe SR, Vos NS, Van Der Schaaf RJ, et al. Two-Year Clinical Outcomes of the REVELATION Study:Sustained Safety and Feasibility of Paclitaxel-Coated Balloon Angioplasty Versus Drug-Eluting Stent in Acute Myocardial Infarction. J Invasive Cardiol. 2022;34:E39–E42. doi: 10.25270/jic/20.00741. [DOI] [PubMed] [Google Scholar]
  • 18.Xue W, Ma J, Yu X, et al. Analysis of the incidence and influencing factors associated with binary restenosis of target lesions after drug-coated balloon angioplasty for patients with in-stent restenosis. BMC Cardiovasc Disord. 2022;22:493. doi: 10.1186/s12872-022-02923-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Coughlan JJ, Maeng M, Räber L, et al. Ten-year patterns of stent thrombosis after percutaneous coronary intervention with new- versus early-generation drug-eluting stents: insights from the DECADE cooperation. Rev Esp Cardiol. 2022;75:894–902. doi: 10.1016/j.rec.2022.02.003. [DOI] [PubMed] [Google Scholar]
  • 20.Madhavan MV, Redfors B, Ali ZA, Prasad M, et al. Long-Term Outcomes After Revascularization for Stable Ischemic Heart Disease: An Individual Patient-Level Pooled Analysis of 19 Randomized Coronary Stent Trials. Circ Cardiovasc Interv. 2020;13:e008565. doi: 10.1161/CIRCINTERVENTIONS.119.008565. [DOI] [PubMed] [Google Scholar]
  • 21.Buchanan KD, Torguson R, Rogers T, et al. In-Stent Restenosis of Drug-Eluting Stents Compared With a Matched Group of Patients With De Novo Coronary Artery Stenosis. Am J Cardiol. 2018;121:1512–1518. doi: 10.1016/j.amjcard.2018.02.033. [DOI] [PubMed] [Google Scholar]
  • 22.Antonio Sorolla Romero J, Calderón AT, Tschischke JPV, Luis Díez Gil J, Garcia-Garcia HM, Sánchez JS. Coronary plaque modification and impact on the microcirculation territory after drug-coated balloon angioplasty:the PLAMI study. Rev Esp Cardiol. 2025;78:481–482. doi: 10.1016/j.rec.2024.10.001. [DOI] [PubMed] [Google Scholar]
  • 23.Merinopoulos I, Gunawardena T, Corballis N, et al. Assessment of Paclitaxel Drug-Coated Balloon Only Angioplasty in STEMI. JACC Cardiovasc Interv. 2023;16:771–779. doi: 10.1016/j.jcin.2023.01.380. [DOI] [PubMed] [Google Scholar]
  • 24.Maranhão RC, Tavares ER, Padoveze AF, Valduga CJ, Rodrigues DG, Pereira MD. Paclitaxel associated with cholesterol-rich nanoemulsions promotes atherosclerosis regression in the rabbit. Atherosclerosis. 2008;197:959–966. doi: 10.1016/j.atherosclerosis.2007.12.051. [DOI] [PubMed] [Google Scholar]
  • 25.Kleber FX, Schulz A, Waliszewski M, et al. Local paclitaxel induces late lumen enlargement in coronary arteries after balloon angioplasty. Clin Res Cardiol Off J Ger Card Soc. 2015;104:217–225. doi: 10.1007/s00392-014-0775-2. [DOI] [PubMed] [Google Scholar]
  • 26.Alfonso F, Rivero F. Late lumen enlargement after drug-coated balloon therapy:turning foes into friends. EuroIntervention J Eur Collab Work Group Interv Cardiol Eur Soc Cardiol. 2024;20:523–525. doi: 10.4244/EIJ-E-24-00026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Yamamoto T, Sawada T, Uzu K, Takaya T, Kawai H, Yasaka Y. Possible mechanism of late lumen enlargement after treatment for de novo coronary lesions with drug-coated balloon. Int J Cardiol. 2020;321:30–37. doi: 10.1016/j.ijcard.2020.07.028. [DOI] [PubMed] [Google Scholar]
  • 28.Ninomiya K, Serruys PW, Colombo A, et al. A Prospective Randomized Trial Comparing Sirolimus-Coated Balloon With Paclitaxel-Coated Balloon in De Novo Small Vessels. JACC Cardiovasc Interv. 2023;16:2884–2896. doi: 10.1016/j.jcin.2023.09.026. [DOI] [PubMed] [Google Scholar]
  • 29.Ahmad WAW, Nuruddin AA, Abdul KMASK, et al. Treatment of Coronary De Novo Lesions by a Sirolimus- or Paclitaxel-Coated Balloon. JACC Cardiovasc Interv. 2022;15:770–779. doi: 10.1016/j.jcin.2022.01.012. [DOI] [PubMed] [Google Scholar]
  • 30.Spaulding C, Krackhardt F, Bogaerts K, et al. Comparing a strategy of sirolimus-eluting balloon treatment to drug-eluting stent implantation in de novo coronary lesions in all-comers: Design and rationale of the SELUTION DeNovo Trial. Am Heart J. 2023;258:77–84. doi: 10.1016/j.ahj.2023.01.007. [DOI] [PubMed] [Google Scholar]
  • 31.Greco A, Sciahbasi A, Abizaid A, et al. Sirolimus-coated balloon versus everolimus-eluting stent in de novo coronary artery disease: Rationale and design of the TRANSFORM II randomized clinical trial. Catheter Cardiovasc Interv Off J Soc Card Angiogr Interv. 2022;100:544–552. doi: 10.1002/ccd.30358. [DOI] [PubMed] [Google Scholar]
REC Interv Cardiol. 2025 Sep 29;8(1):8–16. [Article in Spanish] doi: 10.24875/RECIC.M25000533

Balón farmacoactivo frente a stent farmacoactivo para el tratamiento de la enfermedad coronaria de vaso grande. Metanálisis de ensayos clínicos aleatorizados

José Antonio Sorolla Romero a,◊, Laura Novelli b,◊, Jorge Llau García a, Sara Huélamo Montoro a, Pablo Rubio c, José Luis Díez Gil a,d, Luis Martínez-Dolz a,d, Ignacio J Amat Santos d,e, Bernardo Cortese f,g, Fernando Alfonso d,h, Hector M Garcia-Garcia c, Jorge Sanz-Sánchez a,d,*

RESUMEN

Introducción y objetivos:

Comparar los efectos del balón farmacoactivo (BFA) frente al stent farmacoactivo (SFA) en pacientes con enfermedad arterial coronaria (EAC) de vaso grande de novo.

Métodos:

Se realizó una búsqueda sistemática de ensayos clínicos aleatorizados comparando BFA frente a SFA en pacientes con EAC de vaso grande de novo. Los datos se agruparon mediante un metanálisis de efectos aleatorios. El objetivo primario fue la necesidad de revascularización de la lesión diana (RLD).

Resultados:

Se incluyeron 7 ensayos con 2.961 pacientes. El uso de BFA, en comparación con SFA, se asoció con un riesgo similar de RLD (OR = 1,21; IC95%, 0,44-3,30; I2 = 48%), muerte por todas las causas (OR = 1,56; IC95%, 0,94-2,57; I2 = 0%), muerte de causa cardiovascular (OR = 1,65; IC95%, 0,90-3,05; I2 = 0%), infarto de miocardio (OR = 0,97; IC95%, 0,58-1,61; I2 = 0%), acontecimientos adversos cardiacos mayores (OR = 1,19; IC95%, 0,74-1,90; I2 = 13,5%) y pérdida luminal tardía (DME = −0,35; IC95%, −0,74 a 0.04; I2 = 81,4%). Sin embargo, el BFA se asoció a un mayor riesgo de revascularización del vaso diana (OR = 2,47; IC95%, 1,52-4,03; I2 = 0%) y a un menor diámetro luminal mínimo en el seguimiento (DME: −0,36; IC95%, −0,56 a −0,15; I2 = 34,5%), aunque los intervalos de predicción incluyeron el valor nulo para ambos resultados.

Conclusiones:

En los pacientes con EAC de vaso grande de novo, el BFA comparado con el SFA se asoció a un riesgo similar de RLD, obteniendo el SFA mejores resultados angiográficos.

Palabras clave: Balón farmacoactivo, Stent farmacoactivo, Enfermedad arterial coronaria


Abreviaturas

BFA:

balón farmacoactivo.

DLM:

diámetro luminal mínimo.

EC:

enfermedad coronaria.

IM:

infarto de miocardio.

RLD:

revascularización de la lesión diana.

SFA:

stent farmacoactivo.

VÉASE CONTENIDO RELACIONADO: https://doi.org/10.24875/RECIC.M25000548

INTRODUCCIÓN

En la actualidad, los stents farmacoactivos (SFA) siguen siendo el tratamiento estándar para los pacientes que reciben una intervención coronaria percutánea (ICP)1,2. No obstante, los SFA están asociados a un riesgo paulatino y permanentemente alto de eventos adversos, sobre todo, por la trombosis tardía del stent y la reestenosis intrastent, con una incidencia del 2% anual sin que estos valores hayan alcanzado, todavía, valores meseta1. Este riesgo es, incluso, mayor, cuando se tratan lesiones complejas y largas3. En los últimos años, los balones farmacoactivos (BFA) han surgido como una posible alternativa a los SFA. Tras una adecuada preparación de la lesión, a diferencia de los stents tradicionales, los BFA liberan un fármaco antiproliferativo en la pared vascular sin dejar un armazón metálico permanente tras de sí. Se debe mencionar que el armazón permanente puede distorsionar y constreñir el vaso coronario y, por ende, deteriorar la vasomoción y el remodelado adaptativo promoviendo, en última instancia, la aparición de inflamación crónica4. La ICP con BFA es un tratamiento bien establecido para la reestenosis intrastent y la enfermedad coronaria (EC) de vasos pequeños5,6. No obstante, el papel que juega en la EC de grandes vasos de novo sigue siendo objeto de debate. En un reciente ensayo clínico aleatorizado (ECA) de pacientes revascularizados por EC de novo, una estrategia de ICP con BFA resultó no ser inferior al SFA en el objetivo combinado orientado dispositivo motivado por una mayor incidencia de la revascularización de la lesión diana (RLD)7. Al contrario de lo que apuntan investigaciones ya publicadas, nuestros hallazgos no avalaron resultados clínicos similares para BFA frente a SFA en pacientes con EC de novo de grandes vasos8,9. Un reciente metanálisis de 15 estudios comparó la ICP con BFA o la angioplastia híbrida frente a la ICP con SFA en pacientes con vasos > 2,75 mm de diámetro y confirmó que no había diferencias significativas en los objetivos de RLD, muerte cardiaca e infarto de miocardio (IM)10. No obstante, 14 de los 15 estudios incluidos no eran ECA y el ECA citado anteriormente no fue incluido. En cualquier caso, los estudios individuales de no inferioridad a menudo carecen del potencial estadístico necesario para realizar comparativas concluyentes de estas tecnologías, lo cual pone de manifiesto la necesidad de una evaluación sistemática de los efectos del tratamiento y la calidad de la evidencia. En este sentido, se llevó a cabo una revisión sistemática y metanálisis de los ECA disponibles para realizar una evaluación integral y cuantitativa de la evidencia existente en torno a la eficacia de los BFA frente a los SFA de última generación en la EC de grandes vasos de novo en términos de eventos adversos en el seguimiento más largo disponible.

MÉTODOS

Estrategia de búsqueda y criterios de selección

Se realizó un metanálisis de ECA de conformidad con la declaración PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) de 200911. Dos revisores identificaron de forma independiente los estudios más importantes a través de una búsqueda electrónica en las bases de datos MEDLINE y Embase (desde el principio hasta octubre de 2024). También se empleó el método de bola de nieve inversa (revisión bibliográfica de artículos identificados y revisiones pertinentes). No se impuso ninguna restricción idiomática, fecha ni estado de publicación. Este estudio está registrado en PROSPERO y la estrategia de búsqueda está disponible en el material adicional.

Selección de estudios

Dos revisores valoraron, de forma independiente, la elegibilidad de los ensayos en base a los títulos, resúmenes e informes de texto completo de estos. Las discrepancias en la selección de estudios se debatieron y resolvieron con un tercer investigador. Los estudios elegibles debían cumplir los siguientes criterios preespecificados: a) ECA que compararan ICP con BFA y con SFA; b) población de estudio que incluyera a pacientes con EC de grandes vasos de novo (definidos como aquellos con diámetros vasculares ≥ 2,5 mm)12; c) disponibilidad de datos sobre los objetivos del estudio (sin restricción en cuanto al tiempo de seguimiento). Los criterios de exclusión fueron a) la falta de un diseño aleatorizado; b) estudios que incluyeran a pacientes bajo tratamiento por reestenosis intrastent; c) estudios que incluyeran pacientes con EC de vasos pequeños de novo; d) la falta de datos sobre los objetivos del estudio.

Se estableció un diámetro del vaso de referencia ≥ 2,5 mm como valor de corte para definir los grandes vasos a una definición estandarizada propuesta recientemente12.

Obtención de datos

Tres investigadores (J. Llau García, S. Huélamo Montoro y J.A. Sorolla Romero) evaluaron de forma independiente los estudios para su posible inclusión. Por su parte, el investigador principal (J. Sanz-Sánchez) resolvió cualquier discrepancia que pudiese haber. Los artículos considerados irrelevantes fueron excluidos atendiendo a sus títulos y resúmenes. Los mismos investigadores obtuvieron de manera independiente los datos del diseño del estudio, mediciones, características de los pacientes y resultados empleando un formulario estandarizado para la obtención de datos. Los conflictos en la extracción de datos se debatieron y resolvieron con el investigador principal.

Se recopilaron datos sobre los autores, año de publicación, criterios de inclusión y exclusión, tamaño de la muestra, características basales de los pacientes, definiciones de los objetivos de los estudios, estimaciones del efecto y tiempo de seguimiento.

Objetivos

El objetivo primario preespecificado fue la RLD. Los objetivos secundarios, la mortalidad por cualquier causa, la muerte cardiaca, el infarto de miocardio (IM), la revascularización del vaso diana (RVD) y los eventos adversos cardiovasculares mayores (MACE). Los objetivos angiográficos secundarios fueron el diámetro luminal mínimo (DLM) y la pérdida luminal tardía (PLL). Cada objetivo se evaluó de conformidad con las definiciones descritas en los protocolos de estudio originales, tal y como se muestra en la tabla 1 del material adicional. Todos los objetivos se evaluaron en el seguimiento máximo disponible.

Riesgo de sesgo

El riesgo de sesgo en cada estudio se evaluó utilizando la herramienta revisada de riesgo de sesgo de Cochrane (RoB 2.0)11. Tres investigadores (J. Llau García, S. Huélamo Montoro y J. A. Sorolla Romero) evaluaron de forma independiente 5 dominios de sesgo en los ECA: a) proceso de aleatorización, b) desviaciones de las intervenciones previstas, c) datos de resultados faltantes, d) medición de resultados y e) selección de los resultados informados (tabla 2 del material adicional).

Análisis estadístico

Tanto las odds ratios (OR) como los intervalos de confianza del 95% (IC95%) se calcularon utilizando el modelo de efectos aleatorios de DerSimonian y Laird y la estimación de la heterogeneidad a partir del método de Mantel-Haenszel. La presencia de heterogeneidad entre los estudios se evaluó con la prueba de X2 Q de Cochran, considerándose un valor p ≤ 0,10 como estadísticamente significativo y utilizando la prueba I2 para la valoración de inconsistencias. Un valor de 0% es indicativo de ausencia de heterogeneidad y valores ≤ 25%, ≤ 50%, > 50% de un nivel de heterogeneidad bajo, moderado y alto, respectivamente. Se calcularon intervalos predictivos (95%) además de los IC95% convencionales alrededor de las OR para evaluar la incertidumbre residual. Se evaluó el sesgo de publicación y el efecto de estudio pequeño para todos los objetivos, empleando gráficos de embudo. La presencia de sesgo de publicación se investigó utilizando las pruebas de Harbord y Egger y la estimación visual con gráficos de embudo. Se realizó un análisis de sensibilidad eliminando un estudio cada vez para confirmar que, tras compararlos con los SFA, los hallazgos no eran fruto de un único estudio. Para dar cuenta de las diferentes duraciones del seguimiento entre los estudios, se realizó otro análisis de sensibilidad utilizando el modelo de regresión de Poisson con efectos de intervención aleatorios para calcular los promedios ponderados por la inversa de la varianza de las razones de tasa de incidencia (RTI) estratificadas logarítmicas específicas de cada estudio. Los resultados se expresaron como RTI, es decir, razones exponenciales del modelo de regresión. También se realizaron análisis de metarregresión de efectos aleatorios para evaluar el impacto de las siguientes variables en el efecto del tratamiento con respecto al objetivo primario: porcentaje de pacientes con síndrome coronario agudo (SCA) y diabetes mellitus, diámetro medio del vaso de referencia y duración del seguimiento. El nivel de significación estadística se situó en un valor de p bilateral < 0,05. Se empleó el software Stata versión 18.0 (StataCorp LP, College Station, Estados Unidos) en los análisis estadísticos.

RESULTADOS

Resultados de la búsqueda

La figura 1 ilustra tanto el proceso de búsqueda como la selección de estudios PRISMA. Se identificaron e incluyeron en este análisis un total de 7 ECA. Las características principales de los estudios incluidos se muestran en la tabla 1.

Figura 1. Diagrama de flujo de la búsqueda de estudios incluidos en el metanálisis de conformidad con la declaración PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses).

Figura 1

Tabla 1. Características principales de los estudios incluidos.

Estudio Año de publicación N.º de pacientes Tipo de dispositivo Diámetro del vaso de referencia (media ± DE) (mm) Multicéntrico Seguimiento clínico (meses) Seguimiento angiográfico (meses)
BFA SFA
REC-CAGEFREE I7 2024 1.133 1.139 Paclitaxel-BFA Sirolimus-SFA 3,00 ± 0,55 Sí 24 No
Nishiyama et al.13 2016 30 30 Paclitaxel-BFA Everolimus-SFA 2,80 ± 0,63 No 8 8
Xue Yu et al.8 2022 85 85 Paclitaxel-BFA Everolimus-SFA 2,89 ± 0,33 No 12 9
REVELATION9 2019 60 60 Paclitaxel-BFA Sirolimus y everolimus SFA 3,24 ± 0,50 No 24 9
Gobic et al.15 2017 38 37 Paclitaxel-BFA Sirolimus-SFA > 2,50 No 6 6
Hao et al.16 2021 38 42 Paclitaxel-BFA ND > 2,50 No 12 12
Wang et al.14 2022 92 92 Paclitaxel-BFA Sirolimus-SFA 3,37 ± 0,52 No 12 9

BFA: balón farmacoactivo; ND: no disponible; SFA: stent farmacoactivo.

Todos los estudios tuvieron un diseño de no inferioridad. Se seleccionó un objetivo primario en 1 estudio7 y otro funcional invasivo en otro estudio9; por su parte, los objetivos primarios angiográficos se preespecificaron en los estudios restantes8,13-16. El seguimiento clínico y angiográfico medio fue de 21,5 y 8,9 meses, respectivamente. Se realizaron 4 estudios en el contexto del SCA9,14-17 y 1 en el contexto de síndrome coronario crónico (SCC)13. Por último, 2 estudios incluyeron a pacientes con SCA y SCC7,8. Tres estudios incluyeron a pacientes tratados con SFA de segunda generación (Firebird 2.0 [Microport, China], Xience Xpedition [Abbott Vascular, Estados Unidos], Orsiro [Biotronik, Alemania])7,9,13 y 2 a pacientes tratados con SFA de tercera generación (Biomine [Meril Life Sciences, India], Cordimax [Rientech, China])14,15. Un estudio incluyó a pacientes tratados con SFA de segunda y tercera generación (Xience Xpedition [Abbott Vascular, Estados Unidos], Resolute Integrity [Medtronic, Estados Unidos], Firehawk [MicroPort, China])8. Todos los estudios incluyeron pacientes tratados de ICP con BFA de paclitaxel ([Pantera Lux, Biotronik, Alemania]9,14, [SeQuent Please, B Braun, Alemania]7,8,13,15, [Bingo DCB, Yinyi Biotech, China])16 y ninguno tratados con ICP y BFA de sirolimus.

Características basales

Se incluyó a un total de 2.961 pacientes, 1.476 de los cuales recibieron BFA y 1.485, SFA para el tratamiento de la EC de grandes vasos de novo. Las principales características basales de los pacientes se muestran en la tabla 2.

Tabla 2. Características clínicas basales de los pacientes incluidos.

Estudio Edad (años) Varones (%) Diabetes (%) Tabaquismo (%) Hipertensión (%) FEVI (%) Presentación clínica (SCC/SCA) (%) Multivaso (%) Lesión compleja (%)
REC-CAGEFREE I7 62 69,3 27,3 45 60,1 60 44,9/55,3 4,8 0
Nishiyama et al.13 69 73,3 41,6 60 83,3 ND 0/100 ND 36
Xue Yu et al.8 63,3 69,3 24,1 54 63,9 > 40 11,1/88,9 84 44,1
REVELATION9 57 87 10 60 31 57,6 0/100 71,6 ND
Gobic et al.15 57,4 87 10 49,5 33,4 50,2 0/100 ND ND
Hao et al.16 57,5 78,5 31,5 29,5 24 46 0/100 ND ND
Wang et al.14 49,5 93,5 81,6 81,5 71,8 ND 0/100 ND ND

SCA: síndrome coronario agudo; SCC: síndrome coronario crónico; ND: no disponible.

Sesgo de publicación y asimetría

Las distribuciones de los gráficos de embudo pertenecientes a los resultados preespecificados indican la ausencia de sesgo de publicación para todos los resultados (figuras 1-8 del material adicional).

Evaluación del riesgo de sesgo

La tabla 2 del material adicional muestra los resultados de la evaluación del riesgo de sesgo con la herramienta RoB 2.0. Un estudio se consideró de bajo riesgo general de sesgo7, 5 fueron preocupantes8,9,13,14,16 y 1 presentó, en líneas generales, un alto riesgo de sesgo15.

Resultados

Objetivos

Comparado con el SFA, el BFA se asoció a un riesgo similar de RLD (OR = 1,21; IC95%, 0,44-3,30; I2 = 48%), mortalidad por cualquier causa (OR = 1,56; IC95%, 0,94-2,57; I2 = 0%), muerte cardiaca (OR = 1,65; IC95%, 0,90-3,05; I2 = 0%), IM (OR = 0,97; IC95%, 0,58-1,61; I2 = 0%) y MACE (OR = 1,19; IC95%, 0,74-1,90; I2 = 13,5%). Por su parte, el BFA se asoció a un mayor riesgo de RVD (OR = 2,47; IC95%, 1,52-4,03; I2 = 0%) (figura 2, figura 3 y figuras 9-10 del material adicional).

Figura 2. Diagrama de bosque con las OR específicas del ensayo y resumidas con IC95% para el objetivo de A: revascularización de la lesión diana; B: mortalidad por cualquier causa; C: infarto de miocardio; D: MACE. BFA: balón farmacoactivo; IC95%: intervalo de confianza del 95%; MACE: eventos cardiovasculares adversos mayores; OR: odds ratio; SFA: stent farmacoactivo. Las referencias bibliográficas mencionadas en esta figura corresponden a: REC-CAGEFREE I7, Nishiyama et al.13, Xue Yu et al.8, REVELATION9, Hao et al.16, Wang et al.14 y Gobic et al.15.

Figura 2

Figura 3. Figura central. BFA: balón farmacoactivo; ECA: ensayo clínico aleatorizado; RVD: revascularización del vaso diana; SFA: stent farmacoactivo. Las referencias bibliográficas mencionadas en esta figura corresponden a: REC-CAGEFREE I7, Nishiyama et al.13, Xue Yu et al.8, REVELATION9, Hao et al.16 y Wang et al.14.

Figura 3

Resultados angiográficos

Comparado con el SFA, el BFA produjo un DLM mucho menor (DME = −0,36; IC95%, −0,56 a −0,15; I2 = 34,5%) y un riesgo similar de PLL (DME = −0,35; IC95%, −0,74 a 0,04; I2 = 81,4%) en el seguimiento (figura 4).

Figura 4. Diagrama de bosque con las OR específicas del ensayo y resumidas con IC95% para el objetivo de A: diámetro luminal mínimo y B: pérdida luminal tardía. BFA: balón farmacoactivo; IC95%: intervalo de confianza del 95%; DLM: diámetro luminal mínimo; DME: diferencia de medias estandarizada; MACE: eventos cardiovasculares adversos mayores; OR: odds ratio; SFA: stent farmacoactivo. Las referencias bibliográficas mencionadas en esta figura corresponden a: Nishiyama et al.13, Xue Yu et al.8, REVELATION9, Gobic et al.15, Hao et al.16 y Wang et al.14.

Figura 4

Los intervalos predictivos coincidieron con los IC para todos los resultados, salvo para la RVD y el DLM, que incluyeron el valor de no diferencia.

Análisis de sensibilidad

Se realizó un análisis conjunto de «dejar uno fuera» eliminando iterativamente, cada vez, un estudio para todos los objetivos. Los efectos del tratamiento coincidieron con el análisis principal para la RLD, la mortalidad por cualquier causa, la muerte cardiaca, el IM y el DLM. El riesgo de RVD ya no fue mucho mayor entre los pacientes tratados con BFA tras la eliminación del estudio CAGEFREE I7; por su parte, el riesgo de PLL fue mucho menor entre los pacientes tratados con ICP con BFA tras eliminar el estudio REVELATION9. No obstante, hubo un mayor riesgo de MACE entre los pacientes tratados con ICP con BFA tras la eliminación del estudio de Xue Yu et al.18 (tablas 3-10 del material adicional). El análisis de sensibilidad que se realizó con RTI calculadas para dar cuenta de las diferentes duraciones del seguimiento confirmó que nuestros hallazgos del análisis principal no sufrieron ningún cambio (tabla 11 del material adicional).

El análisis de metarregresión de efectos aleatorios no halló un impacto significativo de la proporción de pacientes con SCA (p = 0,882), diabetes mellitus (p = 0,641), diámetro medio del vaso de referencia (p = 0,985) y duración del seguimiento (p = 0,951) en el efecto del tratamiento con relación al objetivo primario.

DISCUSIÓN

Este metanálisis proporciona un completo y actualizado análisis cuantitativo de la evidencia disponible sobre la comparativa de BFA frente a SFA en el tratamiento de la EC de grandes vasos de novo e incluyó datos de 2.961 pacientes de 7 ECA. Los hallazgos principales del estudio son:

a) El uso del BFA se asoció a un riesgo similar de eventos clínicos frente al SFA, salvo para la RVD. No obstante, los datos de este resultado solo estuvieron disponibles en 3 de los 7 estudios incluidos y el mayor riesgo observado en pacientes tratados de ICP con BFA no fue significativo tras la eliminación del estudio CAGEFREE I. Por su parte, los intervalos predictivos no coincidieron con el IC. En este sentido, los resultados de este desenlace se deben interpretar con cautela.

b) El efecto del BFA sobre el riesgo de RLD no se vio influido por la proporción de pacientes con SCA o diabetes ni por el diámetro medio del vaso de referencia, así como tampoco por la duración del seguimiento, según lo evaluado por el análisis de metarregresión.

c) Aunque los BFA se asociaron a un menor DLM durante el seguimiento angiográfico, la PLL fue parecida a la del SFA.

Los SFA son el patrón oro en pacientes tratados de ICP. No obstante, todavía se observan complicaciones tales como trombosis del stent y reestenosis intrastent con tasas cercanas al 0,7-1% y 5-10% tras 10 años de seguimiento, respectivamente19,20. En este sentido, en los últimos años ha aumentado la preocupación en torno al desarrollo de estrategias para reducir los eventos adversos asociados al stent. En este contexto, el BFA se erige como una posible alternativa de tratamiento a partir de una estrategia de «no dejar nada atrás». No obstante, los datos de pacientes con EC de grandes vasos de novo son pocos y contradictorios. El CAGEFREE I es el único ECA disponible con potencial clínico que incluyó a un total de 2.272 pacientes revascularizados por EC no compleja de novo en 40 centros chinos. La estrategia de ICP con BFA no logró la no inferioridad frente al SFA en lo que respecta al objetivo combinado orientado al dispositivo, impulsado por tasas más altas de RLD en el grupo de ICP con BFA (3,1 frente al 1,2%, p = 0,002)7. Por otro lado, un ECA unicéntrico realizado por Nishiyama et al. de 60 pacientes con SCC tratados de ICP electiva mostró una tendencia hacia tasas más bajas de RLD en el grupo de ICP con BFA (0 frente al 6,1%, p = 0,193) en el seguimiento de 8 meses de duración13. Asimismo, un ECA que incluyó a 170 pacientes tratados de ICP por EC de grandes vasos de novo halló tasas más bajas de RLD en el seguimiento de 12 meses en pacientes tratados de ICP con BFA (1,6 frente al 3,4%, p = 0,306)14. En nuestro análisis, al agrupar los datos de todos los ECA disponibles, el riesgo de RLD fue similar entre pacientes tratados de ICP con BFA o SFA. Se debe mencionar que, como este resultado se obtuvo con una heterogeneidad moderada (I2 ≈ 50%), se debe interpretar con cautela a la hora de cualquier posible extrapolación. Estos hallazgos se mantuvieron inalterados en el análisis de «dejar uno fuera». Además, los intervalos de predicción coincidieron con los IC alrededor de las OR, lo cual demuestra la ausencia de incertidumbre residual. Estudios previos han demostrado que la reestenosis intrastent que sobreviene tras desplegar un SFA no es un fenómeno benigno y se presenta como un SCA en torno al 70% de los casos, resultando entre un 5 y 10% de estos en IM21. Se puede argumentar que la ausencia de un armazón permanente en el BFA frente al SFA predispone a un patrón de reestenosis menos agresivo y a un menor riesgo de oclusión trombótica del vaso > 3 meses después de la cicatrización del vaso tras la ICP con BFA22.

Se debe mencionar que 5 de los 7 estudios de este metanálisis incluyeron a pacientes con SCA. El 34% de los pacientes incluidos en el estudio CAGEFREE presentaban SCA y el 16%, IAMCEST7. Otros 4 estudios solo incluyeron a pacientes con IAMCEST7,9,14-16. Aunque se desconoce el rendimiento de los BFA en el contexto del IAMCEST, su uso está cada vez más extendido en la práctica clínica23. Las placas de la lesión culpable en pacientes con IAMCEST suelen ser blandas y una modificación adecuada de la placa se puede lograr fácilmente mediante ICP con BFA (< 30% de estenosis residual y un grado de disección bajo)23. Además, la placa rica en lípidos rota puede convertirse en un reservorio ideal para una captación efectiva de paclitaxel24. Por otro lado, los BFA se asocian a ciertos riesgos en pacientes con IAMCEST, tales como retroceso agudo y oclusión de la lesión culpable al no contar con un armazón vascular.

En nuestro estudio, la proporción de pacientes con SCA no influyó en los efectos del tratamiento en el análisis de metarregresión. No obstante, se necesitan más ECA con un tamaño de muestra adecuado para contar con evidencias más sólidas sobre esta cuestión. Se debe mencionar que las lesiones complejas, tales como la calcificación grave y las bifurcaciones con técnica programada de doble stent fueron excluidas de los estudios de pacientes con SCC7,8. En este sentido, nuestros hallazgos podrían no ser extrapolables a esta población.

Los mejores resultados angiográficos indirectos obtenidos con ICP con SFA frente a BFA en nuestro metanálisis tras recopilar los datos de 6 estudios podrían explicarse por la ausencia de un armazón metálico para expandir la luz del vaso, así como por el retroceso agudo tras la angioplastia con balón. Esto justifica el menor DLM alcanzado tras la ICP con BFA frente a SFA. Aunque nuestro análisis no mostró diferencias significativas con respecto a la PLL durante el seguimiento, el valor de esta fue menor en pacientes tratados de ICP con BFA tras la eliminación del estudio REVELATION9,17. Este estudio mostró una PLL muy baja tanto en los grupos de BFA como de SFA comparado con otra evidencia disponible de ECA15,16. La presencia de remodelado vascular positivo con agrandamiento tardío de la luz tras el uso del BFA, evaluado mediante técnicas de imagen intracoronarias, se ha evidenciado en muchos estudios y parece estar asociado a la enfermedad de vasos pequeños, placas fibrosas y estratificadas y un arco de disección medial pos-ICP > 90°25-27. No obstante, la evidencia de este fenómeno en pacientes con EC de grandes vasos es menos conocida22. En este sentido, se debe mencionar que todos los estudios de este metanálisis utilizaron BFA de paclitaxel. Aunque la evidencia derivada de una comparativa entre el BFA de sirolimus y paclitaxel es escasa, 2 recientes ECA han hallado mejores resultados angiográficos con el componente lipofílico. En el primero, de 121 pacientes con EC de vasos pequeños de novo, el BFA de sirolimus no logró la no inferioridad para la ganancia neta de luz a los 6 meses28. En el segundo, de 70 pacientes, los 2 dispositivos mostraron resultados similares de PLL a los 6 meses, aunque en pacientes tratados con BFA de paclitaxel el agrandamiento luminal tardío fue un fenómeno más habitual29. Debido al pequeño tamaño de la muestra y aunque no hay suficiente evidencia para evaluar las diferencias entre los objetivos clínicos, no se puede suponer que haya un efecto de clase en todos los BFA. Se están realizando extensos ECA para evaluar los resultados de los BFA de sirolimus frente a los SFA en grandes vasos de los que obtendremos evidencias a este respecto30,31.

Limitaciones

Los resultados de nuestra investigación se deben interpretar teniendo en cuenta algunas limitaciones. En primer lugar, se trata de un metanálisis de estudios que proporciona los efectos promedio del tratamiento. La falta de datos a nivel de pacientes de los estudios incluidos nos impide evaluar el impacto de las características basales clínicas, angiográficas y asociadas a la intervención en los efectos del tratamiento. En segundo lugar, se observaron pequeñas diferencias en la definición de algunos objetivos (por ejemplo, MACE), lo cual limita la fiabilidad de las estimaciones del efecto. En tercer lugar, un estudio representativo del 75% de todos los pacientes incluidos no incluyó seguimiento angiográfico7, lo cual limita la evaluación del BFA y SFA en los resultados angiográficos. En cuarto lugar, el seguimiento clínico fue de entre 6 y 24 meses. Lo ideal es que resultados como la RLD se comparen en seguimientos uniformes entre los distintos estudios (por ejemplo, al año), algo que no fue consistentemente posible en el presente análisis. No obstante, estas diferencias en la duración del seguimiento se tuvieron en cuenta con las RTI, tal y como se detalla en la sección Métodos. En cualquier caso, se necesitan seguimientos más largos para establecer el perfil de seguridad y eficacia del BFA frente al SFA a lo largo del tiempo. En quinto lugar, la definición de vaso grande fue inconsistente entre los estudio y, por lo tanto, una posible fuente de sesgo. Por último, el número limitado de estudios y pacientes y la baja tasa de eventos para objetivos tales como la mortalidad por cualquier causa, podrían minimizar el potencial estadístico necesario para detectar diferencias significativas entre los distintos grupos.

CONCLUSIONES

Este metanálisis proporciona la evidencia cuantitativa más actualizada hasta la fecha sobre el uso de BFA frente a SFA en el tratamiento de la EC de grandes vasos de novo tanto en el SCC como en el SCA. La ICP con BFA se asocia a una RLD y PLL similares en el seguimiento a medio plazo como una opción de tratamiento atractiva para pacientes con EC de grandes vasos.

CONSIDERACIONES ÉTICAS

La aprobación ética se consideró innecesaria para este metanálisis, ya que todos los datos se recopilaron y sintetizaron de estudios previos. Tampoco se consideró necesario obtener el consentimiento informado ya que nuestro trabajo no implicó a ningún paciente en concreto. El metanálisis de ECA se realizó de conformidad con la declaración PRISMA de 2009. Confirmamos haber tenido en cuenta los sesgos de sexo/género.

DECLARACIÓN SOBRE EL USO DE INTELIGENCIA ARTIFICIAL

No se ha utilizado inteligencia artificial en la preparación de este artículo.

CONTRIBUCIÓN DE LOS AUTORES

J. Llau García, S. Huélamo Montoro y J.A. Sorolla Romero participaron en la investigación bibliográfica y selección de estudios. J.A. Sorolla Romero, L. Novelli y J. Sanz Sánchez contribuyeron a la concepción, diseño, redacción y revisión del artículo. P. Rubio, J.L. Luis Díez Gil, L. Martínez-Dolz, I.J. Amat Santos, B. Cortese, F. Alfonso y H.M. Garcia-Garcia contribuyeron a la revisión crítica del contenido intelectual del artículo.

¿QUÉ SE SABE DEL TEMA?

  • – Los BFA son un tratamiento bien establecido para pacientes con EC de vasos pequeños.

  • – La evidencia publicada disponible de pacientes con EC de grandes vasos de novo es escasa y ofrece resultados contradictorios.

¿QUÉ APORTA DE NUEVO?

  • – En el presente metanálisis, con datos de 2.961 pacientes de 7 ECA, los BFA mostraron un riesgo similar de eventos clínicos en el seguimiento que los SFA en el tratamiento de la EC de grandes vasos de novo.

  • – El uso del BFA podría considerarse una opción alternativa al SFA en pacientes tratados de ICP por EC no compleja de grandes vasos de novo.

Funding Statement

Ninguna.

Footnotes

CONFLICTO DE INTERESES: F. Alfonso es editor asociado de REC: Interventional Cardiology; se ha seguido el procedimiento editorial establecido en la revista para garantizar la gestión imparcial del manuscrito. Los autores no declararon ninguna relación importante con el contenido del presente artículo.

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    Supplementary data

    Supplementary material associated with this article.


    Articles from REC: Interventional Cardiology are provided here courtesy of Sociedad Española de Cardiología

    RESOURCES