Abstract
Lonicerae japonicae Flos (LjF, honeysuckle) is a major component of beverages and healthcare products, as well as a key botanical resource in traditional Chinese medicine. Chlorogenic acids (CGAs) are the main bioactive components of LjF, possessing antioxidant, anti‐inflammatory, antiviral, and other biological activities, among which CGA serves as the key marker compound for LjF quality evaluation. In the present work, LjF samples were subjected to controlled dry heating and analyzed by LC‐DAD and UPLC‐QTOF‐MS. Progressive degradation of neochlorogenic acid, cryptochlorogenic acid, and isochlorogenic acid A was accompanied by concomitant accumulation of CGA, isochlorogenic acid B, and isochlorogenic acid C. Furthermore, the effects of temperature and time on thermal transformation, along with key chemical markers for different heat treatment conditions were clarified via principal component analysis of chemical changes. Mechanistic investigations revealed that isochlorogenic acid A undergoes competitive cleavage of the C‐3 or C‐5 caffeoyl ester bond to yield neochlorogenic acid (kinetic product) or CGA (thermodynamic product), followed by intramolecular acyl migration to form isochlorogenic acid B and isochlorogenic acid C, with isochlorogenic acid C identified as the most stable dicaffeoyl isomer. The interconversion of monocaffeoyl isomers leads to a dynamic equilibrium, with CGA being the predominant and most stable form. These results provide the comprehensive thermal‐transformation map for CGAs in LjF and offer practical guidance for optimizing drying, roasting, and extraction protocols in the development of high‐quality LjF, an edible and medicinal homologous resource.
Keywords: honeysuckle, isochlorogenic acid, kinetic transformation, thermal degradation, thermodynamic transformation
1. Introduction
Lonicerae japonicae Flos (LjF, Jinyinhua, Honeysuckle) originates from the dried flower buds or partially opened flowers of Lonicera japonica Thunb, belonging to the Caprifoliaceae family. It is primarily distributed in East Asian countries including China, South Korea, and Japan. First introduced to the United States [1] in the 19th century, it has since been reported in Europe, Canada [2], and other areas. Presently, the applications of LjF extend significantly beyond medicinal purposes, finding extensive development within commercial sectors including food, beverages, and healthcare products. With its broad application prospects, its annual demand in China reaches approximately 30,000 t. Existing studies on compositional changes are primarily confined to the biological field [3] and to storage or drying methods [4]. Research on the transformation of chlorogenic acids (CGAs), the key bioactive constituents of LjF during dry heating is currently lacking.
In LjF, CGAs primarily comprise six specific isomers: neochlorogenic acid, CGA, cryptochlorogenic acid, isochlorogenic acid A, isochlorogenic acid B, and isochlorogenic acid C [5], whose chemical structures are depicted in Figure 1. Neochlorogenic acid, CGA, and cryptochlorogenic acid are termed monocaffeoylquinic acids; simultaneously, isochlorogenic acid A, isochlorogenic acid B, and isochlorogenic acid C are classified as dicaffeoylquinic acids.
Figure 1.

Chemical structures of CGAs. (A) caffeic acid; (B) quinic acid; (C) chlorogenic acid (3‐O‐caffeoylquinic acid); (D) neochlorogenic acid (5‐O‐caffeoylquinic acid); (E) cryptochlorogenic acid (4‐O‐caffeoylquinic acid); (F) isochlorogenic acid A (3,5‐di‐O‐caffeoylquinic acid); (G) isochlorogenic acid B (3,4‐di‐O‐caffeoylquinic acid); and (H) isochlorogenic acid C (4,5‐di‐O‐caffeoylquinic acid).
As the key marker compound for evaluating the quality of LjF [6], CGA exhibits a broad spectrum of pharmacological activities, including anti‐inflammatory [7], antibacterial [8], antioxidant [9], antiviral [10], hepatoprotective effect [11], cardioprotective effect [12], antiobesity action [13], amelioration of ovarian impairment [14], cancer prevention and treatment [15], and reduction of the risk of neurological diseases such as Alzheimer′s disease [16], cognitive dysfunction [17], and Parkinson′s disease [18].
Likewise, although dicaffeoylquinic acids have not been studied extensively as CGA to date, they still exhibit a broad spectrum of pharmacological activities [19]. Notably, isochlorogenic acid C, among the dicaffeoylquinic acids, exhibits the most potent antioxidant and antibacterial activities, whereas isochlorogenic acid A and isochlorogenic acid B demonstrate comparable potency [20, 21]. However, isolation, purification, identification, and quality evaluation of isochlorogenic acids B and C predominantly rely on extraction from natural sources [22–24], resulting in prohibitively high costs that impede related research.
Current investigations into the thermal stability of monocaffeoylquinic acids are relatively comprehensive [25], yet predominantly focus on CGA itself under ultrahigh temperatures [26] or in solution [27]. Most existing research employed either temperature or time as a single variable, centered on CGA; however, the exploration of its transformation and interrelationship with dicaffeoylquinic acids was insufficient.
In this contribution, via dry‐heat methodology with solvent effects excluded, the coupled effects of heating temperature and duration on active components, CGAs, in LjF were systematically investigated, aiming to enhance the contents of CGA, isochlorogenic acid B, and isochlorogenic acid C. Furthermore, the thermal transformation relationships of CGAs in LjF were systematically elaborated at the mechanistic level, along with a novel mechanistic insight: neochlorogenic acid and CGA are the kinetic and thermodynamic degradation products of isochlorogenic acid A, respectively.
2. Materials and Methods
2.1. Materials and Reagents
LjF samples originated from Henan Province, China. HPLC grade methanol was procured from Shanghai Wohua Chemical Co. Ltd (Shanghai, China). MS grade acetonitrile was purchased from Merck (United States). Formic acid was sourced from Shanghai Lingfeng Chemical Reagent Co. Ltd (Shanghai, China). The CGA reference standard (≥ 98% pure) was purchased from Shanghai Dibai Biotechnology Co. Ltd (Shanghai, China). The reference standards for isochlorogenic acid A (≥ 98% pure), isochlorogenic acid B (≥ 98% pure), and isochlorogenic acid C (≥ 98% pure) were obtained from Chengdu Yijierui Biotechnology Co. Ltd (Chengdu, China). The ultrapure water was prepared using a PLUS‐E2‐10TJ laboratory ultrapure water purification system (Nanjing Eped Technology Development Co. Ltd, Nanjing, China). The DZX‐3 (6020B) vacuum drying oven (Shanghai Fuma Experimental Equipment Co. Ltd.) was used for the dry‐heat treatment process.
2.2. Probing the Transformation of CGAs
2.2.1. Sample Preparation
A total of 5 g of LjF powder samples were placed in the vacuum drying oven and heated at 60°C, 80°C, 100°C, 120°C, 140°C, and 160°C, respectively, for 15 min. Separate batches of the LjF powder samples were heated in the oven at 80°C, 100°C, and 120°C for 30, 60, 90, and 120 min, respectively. Following heat treatment, 0.1 g of each sample was extracted with 10 mL of 80% (V/V) methanol with an ultrasonic extractor (power 300 W, frequency 40 kHz) for 60 min. The samples were then filtered through a 0.22‐μm nylon filter membrane and subjected to analysis.
2.2.2. HPLC Analysis Method
Chromatographic analysis was performed using an Agilent 1200 HPLC system (Agilent Technologies, China), equipped with a thermostatted compartment, a UV diode array detector (DAD), a binary pump, and an autosampler. Separation was achieved on a WonCract ODS‐2 column (4.6 × 150 mm, 5 μm) maintained at 30°C. The mobile phase consisted of Solvent A (0.1% formic acid, V/V) and Solvent B (acetonitrile), employing the following gradient program: 0–8 min, 14%–19% B; 8–14 min, 19% B; 14–34 min, 19%–31% B; 34–35 min, 31%–90% B; 35–40 min, 90% B; 40–42 min, 90%–14% B; 42–50 min, 14% B. The flow rate was 0.7 mL/min, the injection volume was 10 μL, and UV detection was performed at 327 nm. The method validation of HPLC in this study, covering accuracy, stability, repeatability, and recovery, is included in Supporting Information 1
2.2.3. LC‐QTOF‐MS Analysis Method
Analysis was conducted using an Agilent 1290 UHPLC system (Agilent Technologies, China), equipped with a thermostatted compartment, a UV DAD, a binary pump, and an autosampler. The chromatographic conditions were adopted from Section 2.2.2. The system was equipped with the same WonCr act ODS‐2 column (4.6 × 150 mm, 5 μm) as used in Section 2.2.2, because UHPLC systems are compatible with conventional HPLC columns. Moreover, a splitter was installed between the LC and the MS to regulate the eluent flow rate to match the mass spectrometer requirements. For mass spectrometric analysis, MS data were acquired in TOF mode using ESI (−) negative ion mode scan. The operating parameters were configured as follows: drying gas and collision gas, N2; drying gas temperature, 350°C; drying gas flow rate, 10 L/min; nebulizer pressure, 30 psi; capillary voltage, 3000 V; skimmer voltage, 65 V; octabar RF voltage, 750 V; capillary exit voltage, 150 V; and mass scan range, m/z 50–1000. For targeted MS/MS analysis, collision energy values were individually set at 20 and 40 eV based on the fragmentation characteristics of the target ions.
2.2.4. Kinetic and Thermodynamic Transformation Process of CGAs
A total of 5 g of LjF powder samples were placed in the vacuum drying oven and heated at 120°C for 5 and 120 min, respectively. Following heat treatment, the samples were rapidly cooled. Subsequently, 0.1 g of both heat‐treated samples alongside the untreated sample were individually immersed in 10 mL of 80% (V/V) methanol. Extraction was performed using ice‐bath ultrasonic extraction (power 300 W, frequency 40 kHz) for 10 min. The resulting extracts were filtered and then subjected to analysis. The HPLC method employed was identical to that described in Section 2.2.2.
3. Results and Discussion
3.1. Identification of the CGAs in LjF
3.1.1. Identification of the CGAs by HPLC
Figure 2 depicts the chromatograms of the reference standards, the untreated LjF sample, and the sample subjected to heat treatment at 120°C for 120 min, under the HPLC conditions specified in Section 2.2.2.
Figure 2.

HPLC chromatograms of the typical samples. (A) HPLC chromatogram of the reference standard; (B) HPLC chromatogram of the untreated sample; and (C) HPLC chromatogram of the sample treated at 120°C for 120 min. Peak 1, neochlorogenic acid; Peak 2, chlorogenic acid; Peak 3, cryptochlorogenic acid; Peak 4, isochlorogenic acid B; Peak 5, isochlorogenic acid A; and Peak 6, isochlorogenic acid C.
3.1.2. Identification of the CGAs by LC‐QTOF‐MS
Figure 3 expresses the chromatograms obtained from total ion chromatogram (TIC) of the sample treated at 140°C for 15 min under the LC‐QTOF‐MS conditions detailed in Section 2.2.3.
Figure 3.

Total ion chromatogram (TIC) of the sample treated at 140°C for 15 min under the conditions specified in Section 2.2.4. Peak 1, neochlorogenic acid; Peak 2, chlorogenic acid; Peak 3, cryptochlorogenic acid; Peak 4, isochlorogenic acid B; Peak 5, isochlorogenic acid A; and Peak 6, isochlorogenic acid C.
Based on the mass spectrometric data acquired in this work and previous works [28–31], Peak 1 was identified as neochlorogenic acid, Peak 2 as CGA, Peak 3 as cryptochlorogenic acid, Peak 4 as isochlorogenic acid B, Peak 5 as isochlorogenic acid A, and Peak 6 as isochlorogenic acid C.
Since LC‐QTOF‐MS was used only for qualitative identification, full method validation was not performed. However, to ensure reliable identification, the mass accuracy was maintained within 5 ppm, and the retention time repeatability was RSD < 0.55% by analyzing 12 samples. The fragment ions were stable across repeated injections. The MS/MS data for the six principal analytes targeted in this study are presented in Table 1. The six most abundant fragment ions were selected and sorted in descending order of abundance.
Table 1.
MS/MS data from the LC‐QTOF‐MS spectra of the samples after heat treatment.
| Types | tR (min) | Formula | [M−H]− | MS/MS (20 eV) | MS/MS (40 eV) | Analytes |
|---|---|---|---|---|---|---|
| Monocaffeoylquinic acids | 5.034 | C16H18O9 | 353.0854 |
|
|
Neochlorogenic acid |
| 7.164 | C16H18O9 | 353.0863 |
|
|
Chlorogenic acid | |
| 8.620 | C16H18O9 | 353.0854 |
|
|
Cryptochlorogenic acid | |
| Dicaffeoylquinic acids | 20.900 | C25H24O12 | 515.1174 |
|
|
Isochlorogenic acid B |
| 23.171 | C25H24O12 | 515.1161 |
|
|
Isochlorogenic acid A | |
| 25.681 | C25H24O12 | 515.1178 |
|
|
Isochlorogenic acid C |
For monocaffeoylquinic acids, in negative ion mode, if CGA (C16H17O9, m/z 353) loses one molecule of caffeoyl group (C9H6O3, m/z 162), it yields quinic acid (C7H11O6, m/z 191). In negative ion mode, the caffeoyl group (C9H6O3, m/z 162) loses a proton to form a fragment ion with m/z 161. When CGA (C16H17O9, m/z 353) loses one molecule of caffeic acid (C9H7O4, m/z 179), the remaining moiety yields a fragment ion with m/z 174. Quinic acid (C7H11O6, m/z 191) loses one molecule of water to form dehydrated quinic acid fragment at m/z 173; on this basis, if it loses another molecule of water, it yields a fragment ion with m/z 155, and if it undergoes decarboxylation upon heating, it forms a fragment ion with m/z 127. The caffeoyl group (C9H6O3, m/z 162) loses one molecule of water to yield a fragment ion with m/z 143. After caffeic acid (C9H7O4, m/z 179) undergoes decarboxylation upon heating, it forms a fragment ion with m/z 135.
For dicaffeoylquinic acids, in negative ion mode, isochlorogenic acid (C25H24O12, m/z 515) loses one molecule of caffeoyl group (C9H6O3, m/z 162) to yield monocaffeoylquinic acids (m/z 353), which then lose one molecule of water to form dehydrated monocaffeoylquinic acids at m/z 335. Most of the other fragment ion peaks are obtained based on the fragmentation of monocaffeoylquinic acids. The ion abundance spectra of above‐mentioned MS data for the six compounds is included in Supporting Information 2.
3.2. The Thermal Stability of the CGAs in LjF
3.2.1. The Thermal Stability of the Monocaffeoylquinic Acids
As illustrated in Figure 4A, the neochlorogenic acid increased relative to the untreated LjF sample following heat treatment at 60°C, 80°C, and 100°C. Subsequently, a progressive decline was observed with further temperature elevation. Neochlorogenic acid concentration exhibits an initial increase followed by a decrease postheat treatment. This pattern indicates generation of new neochlorogenic acid within a specific temperature range; however, at higher temperatures, its reduction exceeded generation. Notably, a sharp decline occurred between 100°C and 180°C. Compared with the untreated sample, the neochlorogenic acid was elevated at 60°C, whereas under the destructive condition of 200°C, it was reduced.
Figure 4.

Effect of heating temperature on the peak areas of different CGAs (15‐min treatment). (A) neochlorogenic acid; (B) chlorogenic acid; and (C) cryptochlorogenic acid. Data are presented as mean ± RSD (n = 3).
As depicted in Figure 4B, the CGA progressively increased following heat treatment within the temperature range of 60°C–140°C, achieving a maximum enhancement relative to the untreated sample. Beyond 140°C, the content underwent a rapid decline, decreasing to 22.20% of its peak value and 14.73% of the level observed in the untreated sample. This behavior demonstrates that CGA, analogous to neochlorogenic acid, exhibits an initial concentration increase followed by a decrease upon more extreme thermal processing. This signifies generation of new CGA within a specific thermal range, succeeded by degradation processes exceeding its generation rate at elevated temperatures.
As shown in Figure 4C, the cryptochlorogenic acid decreased significantly following heat treatment. This indicates that the degradation and transformation of cryptochlorogenic acid under thermal conditions exceeded its rate of generation.
Figure 5A demonstrates that neochlorogenic acid was elevated relative to the untreated sample after heating at 80°C. Though this elevation diminished with prolonged heating at 80°C, it indicates that the reduction lagged behind the generation. At 100°C, neochlorogenic acid increased after 15 min of heating and subsequently declined; the rate of decline decelerated after 90 min. It signifies that initially, production exceeded reduction; as time elapses, reduction surpasses production, with eventual equilibrium. At 120°C, neochlorogenic acid underwent a substantial immediate decrease, with the declining trend slowing later; this reflects accelerated initial degradation at higher temperatures, ultimately reaching a quasi‐equilibrium. For identical durations, higher temperatures were observed to reduce its content, similar to Figure 4A.
Figure 5.

Changes in the peak area of CGAs under various heat treatment conditions. (A) neochlorogenic acid; (B) chlorogenic acid; and (C) cryptochlorogenic acid. Data are presented as mean ± RSD (n = 3).
Figure 5B illustrates CGA after heat treatment at 80°C exceeded the untreated LjF sample. It increased with extended heating duration and reached maximum concentration at 120 min. At 100°C, CGA increased during the initial 15–60 min and remained higher than the untreated sample. A turning point emerged at 60 min, after which it declined from the peak yet still exceeded the untreated sample. At 120°C, CGA similarly rose initially then reduced with an earlier inflection point at 30 min compared with 60 min at 100°C, and all remained higher than the untreated sample. With 15 min of heating, CGA rose with increasing temperature; whereas for 120 min, it decreased as temperature increased. After heating for 30, 60, and 90 min, it first increased then decreased, reflecting dynamic shifts in relative rates of generation and degradation across the temperature gradient. Figure 5C demonstrates that under 80°C heating for 90 min, the cryptochlorogenic acid decreased, whereas from 90 to 120 min, it underwent a further reduction. At 100°C, heating for 30 min, cryptochlorogenic acid plunged, whereas a slow reduction occurring between 30 and 120 min. Under 120°C conditions, the content declined more sharply in the period immediately after 30 min of heating than it did from 30 to 120 min. The cryptochlorogenic acid consistently decreased with prolonged heating time, with the reduction rate gradually slowing until relative equilibrium was reached. Furthermore, elevated temperatures not only enhanced the initial rate of decline but also induced a reduction in the final equilibrium content attained following prolonged heating with increasing temperature.
3.2.2. The Thermal Stability of the Dicaffeoylquinic Acids
As shown in Figure 6A, the isochlorogenic acid A decreased significantly following heat treatment. Within the temperature range of 60°C–100°C, the extent of its decomposition and transformation was relatively limited. However, a substantial increase in decomposition and transformation was observed between 100°C and 180°C. Beyond this temperature range, the content stabilized. These results indicate that under thermal conditions, the degradation and transformation of isochlorogenic acid A exceeded its generation. As shown in Figure 6B, isochlorogenic acid B gradually increased with heat treatment at 60°C–180°C: slow increase at 60°C–80°C, accelerating notably at 80°C–180°C, peaking at 180°C versus the untreated sample. Beyond 180°C, it decreased. This pattern, similar to CGA and neochlorogenic acid, shows that initial increase then decrease within a specific temperature range, indicating generation in a thermal window followed by degradation and transformation dominance at higher temperatures. As shown in Figure 6C, isochlorogenic acid C increased gradually with heat treatment at 60°C–160°C, with a marked increase at 80°C–140°C that was faster than that at 60°C–80°C and 140°C–160°C. It peaked at 160°C, significantly higher than the untreated sample, and declined beyond 160°C. Like CGA, neochlorogenic acid, and isochlorogenic acid B, it first increased then decreased upon thermal processing, indicating generation in a specific range followed by degradation dominance at elevated temperatures. Its inflection point was 20°C earlier than that of isochlorogenic acid B.
Figure 6.

Effect of heating temperature on the peak area of different CGAs (15‐min treatment). (A) isochlorogenic acid A; (B) isochlorogenic acid B; and (C) isochlorogenic acid C. Data are presented as mean ± RSD (n = 3).
Figure 7A illustrates that isochlorogenic acid A decreased at 80°C after 120 min of heat treatment, with greater reductions at 100°C and 120°C, in increasing order. It consistently declined with prolonged heating time. Higher temperatures accelerated the decrease rate and resulted in a greater overall reduction magnitude. Figure 7B demonstrates that after 120 min of heat treatment at 80°C, 100°C, and 120°C, the isochlorogenic acid B increased, with the increase becoming more pronounced as temperature rose. It consistently increased with prolonged heating across all tested temperatures. Higher temperatures enhanced both the magnitude and rate of increase, leading to greater elevation at equivalent durations. Data suggest temperature elevation influences its increase more significantly than extended heating time.
Figure 7.

Changes in the peak areas of CGAs under various heat treatment conditions. (A) isochlorogenic acid A; (B) isochlorogenic acid B; and (C) isochlorogenic acid C. Data are presented as mean ± RSD (n = 3).
Figure 7C demonstrates that isochlorogenic acid C exhibited a content change pattern similar to isochlorogenic acid B. After heating for 120 min, it increased, with the increment more marked at higher temperatures. Furthermore, the variation of isochlorogenic acid C exhibited greater sensitivity to temperature changes compared with isochlorogenic acid B.
3.2.3. Analysis of Component Changes
Principal component analysis (PCA) was employed to evaluate the combined effects of temperature and time on the compositional changes of CGAs in LjF. By integrating score and loading plots, the study is aimed at identifying key chemical markers and optimal processing conditions that maximize sample discriminability.
In Figure 8A, when examining the effect of heating time at 100°C, PCA demonstrated that most compositional changes occurred within the first 30 min. Samples treated for 60–120 min clustered closely, suggesting limited further transformation. In Figure 8B, the PC1 axis was mainly influenced by isochlorogenic acids A and C, whereas PC2 was driven by CGA and, to a lesser extent, cryptochlorogenic acid. The convergence of scores over time indicated reaction stabilization, with extended heating offering no additional discriminatory benefit.
Figure 8.

PCA plots of chlorogenic acids in LjF under different thermal processing conditions. (A) PCA score plot for samples heated at 100°C for different durations (15–120 min); (B) PCA loading plot under heat treatment at 100°C; (C) PCA score plot for samples heated at different temperatures (60°C–200°C) for 15 min; and (D) PCA loading plot under 15 min of heat treatment.
In Figure 8C, under 15 min of heat treatment, PCA revealed a clear temperature‐dependent segregation of samples. The 100°C–160°C range exhibited the greatest dispersion along PC1, indicating the most significant chemical differentiation. In Figure 8D, loading analysis showed that isochlorogenic acid A (positive loading) and isochlorogenic acids B and C (negative loadings) were the primary contributors to this separation. PC2 was dominated by CGA, whose trend of initial increase followed by decrease aligned with the observed score pattern, reflecting complex degradation and interconversion dynamics.
In conclusion, PCA results effectively distinguishes LjF samples based on CGA profiles under thermal treatment. Temperature is the dominant factor, with 100°C–160°C being the most informative range, whereas time effects plateau after 30 min. The six CGAs, particularly dicaffeoylquinic acids and CGA, serve as reliable chemical markers for monitoring thermal processing, providing a basis for quality control and optimization in functional food production.
3.2.4. The Degradation and Transformation Pathway of Isochlorogenic Acid A
Based on mass spectrometric analysis of isochlorogenic acid A, it is proposed that the kinetic and thermodynamic degradation products of isochlorogenic acid A are distinct. This finding contrasts with reports in the literature [32, 33], which contend that CGA is its sole degradation product. We designed the experiment described in Section 2.2.4 to verify the hypothesis.
As shown in Figure 9, after treatment at 120°C for 5 min, the content of neochlorogenic acid increased significantly by 15.05%, whereas that of CGA decreased by 3.41%. The concentration of cryptochlorogenic acid rose by 4.02%, whereas isochlorogenic acids B, A, and C decreased by 5.30%, 3.73%, and 2.07%, respectively. The decrease in isochlorogenic acid A after short‐term high‐temperature treatment indicates its transformation or degradation to other compounds. Moreover, isochlorogenic acids B and C also decreased slightly, indicating that isochlorogenic acid A tends to lose one caffeoyl group to form monocaffeoylquinic acids during thermal transformation, rather than generating other dicaffeoylquinic acids via positional isomerization of caffeoyl moieties. Upon further heating at 120°C for 120 min, neochlorogenic acid declined and CGA increased. Cryptochlorogenic acid was drastically reduced by 53.97% compared with the untreated sample, and isochlorogenic acids B and C were remarkably elevated by 184.8% and 463.27%, respectively, whereas isochlorogenic acid A exhibited a decreasing trend.
Figure 9.

Relationship between heat treatment time and the peak areas. (A) neochlorogenic acid; (B) chlorogenic acid; (C) cryptochlorogenic acid; (D) isochlorogenic acid B; (E) isochlorogenic acid A; and (F) isochlorogenic acid C. Data are presented as mean ± RSD (n = 3).
As depicted in Figure 1, the two caffeic acid units in isochlorogenic acid A are esterified at the 3‐ and 5‐hydroxyl groups of the quinic acid core. As illustrated in Figure 10, while cleavage at the 5‐position produces CGA, cleavage of the ester bond at the 3‐position yields neochlorogenic acid. CGA is thermodynamically favored under prolonged heating, whereas neochlorogenic acid tends to form as a transient intermediate. Specifically, during extended heating periods, this class of compounds exhibits a preferential transformation toward CGA rather than neochlorogenic acid. Namely, the observed content changes—increased neochlorogenic acid and decreased CGA following brief high‐temperature exposure—indicate that the rise in neochlorogenic acid primarily originates from thermal degradation of isochlorogenic acid A rather than interconversion among other monocaffeoylquinic acids. Collectively, these findings demonstrate that isochlorogenic acid A preferentially generates neochlorogenic acid under short‐term high‐temperature conditions, leading us to conclude that neochlorogenic acid serves as its kinetic degradation product.
Figure 10.

The degradation pathway of isochlorogenic acid A.
Is the thermodynamic degradation product of isochlorogenic acid A also neochlorogenic acid? Likewise, how to explain the phenomenon of increased CGA caused by the thermal degradation of isochlorogenic acid A? The neochlorogenic acid increases significantly after short‐term heat treatment but decreases markedly following prolonged exposure. Conversely, CGA decreases initially after heating but increases after extended treatment. This differential behavior indicates shifting generation and degradation rates between these two compounds with prolonged heating duration. More specifically, it is concluded that the primary degradation products of isochlorogenic acid A shift from neochlorogenic acid under kinetic control to CGA under thermodynamic control. Consequently, it is demonstrated that the degradation products of isochlorogenic acid A consist of neochlorogenic acid as the kinetic product under short‐term conditions and CGA as the thermodynamic product following extended thermal exposure.
According to the reported work [20], the direct synthesis of diacyl compounds, without enzyme catalysis, from monocaffeoylquinic acids under mild heating is challenging, requiring more stringent conditions to form dicaffeoylquinic acids. Research work [34] also reports that in caffeoylquinic acids, caffeic acid can migrate to different binding sites on the quinic acid core under heating, namely, intramolecular acyl transfer occurs. Therefore, the increase in isochlorogenic acid B (3,4‐dicaffeoylquinic acid) and isochlorogenic acid C (4,5‐dicaffeoylquinic acid) may also primarily stem from isochlorogenic acid A (3,5‐dicaffeoylquinic acid).
In summary, isochlorogenic acid A not only decomposes into its kinetic degradation product, neochlorogenic acid, and its thermodynamic degradation product, CGA, under different heating conditions, but also undergoes intramolecular acyl migration, where one caffeic acid moiety migrates to a different hydroxyl group on the quinic acid, to form isochlorogenic acids B and C.
3.3. The Transformation of CGAs After Heat Treatment
Based on the descriptions and preliminary analyses in Sections 3.2.1–3.2.4, the result clearly demonstrate that isochlorogenic acid A, cryptochlorogenic acid, and neochlorogenic acid decreased significantly after heat treatment, whereas CGA, isochlorogenic acid B, and isochlorogenic acid C increased. Through analysis of the structures of these six compounds, relevant works [34–36], and experimental data, the dynamic transformation patterns of six key CGAs under dry‐heating treatment were systematically elucidated. Figure 11 illustrates the proposed interconversion pathways among the six major CGAs, centered around isochlorogenic acid A.
Figure 11.

The pathways for the conversion among CGAs.
In light of the analysis in Section 3.2.4, it is proposed that isochlorogenic acid A is converted into isochlorogenic acids B and C upon heat exposure. Notably, after heat treatment, among the three dicaffeoylquinic acid isomers, the increase of isochlorogenic acid C is greater than that of isochlorogenic acid B. This suggests that under the provided dry‐heat conditions, isochlorogenic acid C is likely the thermodynamically most stable configuration. It is speculated that this may be attributed to the more symmetrical arrangement of the two caffeoyl groups in isochlorogenic acid C, which results in a more stable overall molecular conformation.
Structural and mass spectrometric analysis of three dicaffeoylquinic acids indicates that dicaffeoylquinic acids primarily lose one caffeoyl moiety under thermal stress, generating monocaffeoylquinic acids. Two potential cleavage sites exist between the caffeic acid and quinic acid units in every dicaffeoylquinic acid. Via mass spectrometric analysis, high similarity in spectral characteristics between the spectra of isochlorogenic acid B (3,4‐dicaffeoylquinic acid) and isochlorogenic acid C (4,5‐dicaffeoylquinic acid) was revealed. Meanwhile, their secondary mass spectra also showed significant similarity to that of cryptochlorogenic acid (4‐O‐caffeoylquinic acid). It is therefore inferred that during mass spectrometric fragmentation, the 3‐position acyl group in isochlorogenic acid B and the 5‐position acyl group in isochlorogenic acid C are preferentially cleaved, yielding characteristic fragments of cryptochlorogenic acid. This indicates that under the experimental condition of short‐term heating, the main degradation product of both isochlorogenic acid B and isochlorogenic acid C is cryptochlorogenic acid. Although cryptochlorogenic acid was formed from isochlorogenic acid B and C under short‐term heating, its content still declined as the heat treatment time extended.
The decrease of cryptochlorogenic acid and neochlorogenic acid as well as the increase of CGA were observed. These three monocaffeoylquinic acids undergo mutual conversion during heating; however, under elevated temperatures, both cryptochlorogenic acid and neochlorogenic acid tend to convert into CGA as CGA constitutes the thermodynamically stable component among the three monocaffeoylquinic acids. Furthermore, all monocaffeoylquinic acids also undergo further degradation. This explains the decrease of cryptochlorogenic acid and neochlorogenic acid and the increase of CGA.
Upon high‐temperature heating of LjF, three main types of interconversions occur among its six major CGAs. The first involves mutual transformations within monocaffeoylquinic acids, ultimately stabilizing as CGA. The second entails interconversions within dicaffeoylquinic acids; under the experimental conditions employed in this study, isochlorogenic acid A transforms into isochlorogenic acids B and C, with the latter being the more stable thermodynamic product. The third type is the conversion of dicaffeoylquinic acids to monocaffeoylquinic acids.
4. Conclusion
In conclusion, this work elucidates the thermal degradation and transformation of CGAs in LjF under dry heating. We demonstrate that dry heating drives distinct conversion pathways: the interconversion of neochlorogenic and cryptochlorogenic acids to CGA, and the isomerization of isochlorogenic acid A to B/C via intramolecular acyl migration, concurrently yielding neochlorogenic acid (kinetically favored) and CGA (thermodynamically stable). These findings establish the first comprehensive thermal reaction network for CGAs in LjF, providing a scientific foundation for optimizing processing parameters to enhance the quality and efficacy of LjF‐derived products.
Funding
This study was supported by National Natural Science Foundation of China (Nos. 81573397 and 81973285).
Conflicts of Interest
The authors declare no conflicts of interest.
Supporting Information
Additional supporting information can be found online in the Supporting Information section.
Supporting information
Supporting Information 1 The method validation of the high‐performance liquid chromatography (HPLC) adopted in this study, covering accuracy, stability, repeatability, and recovery.
Supporting Information 2 The mass spectrometry (MS) data of ion abundance for the six compounds.
Acknowledgments
The authors acknowledge the Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism for its support.
Zhao, Peishan , Dong, Kaixiang , Liu, Yan , Zhang, Hongyang , Jia, Qiangqiang , Wang, Yuerong , Hu, Ping , Zhang, Min , Investigating the Thermal Transformations of Chlorogenic Acids During Dry‐Heating Processing of Lonicerae Japonicae Flos , International Journal of Food Science, 2026, 7566064, 14 pages, 2026. 10.1155/ijfo/7566064
Academic Editor: Florencio Reginio
Contributor Information
Yan Liu, Email: liuyancrystal@ecust.edu.cn.
Min Zhang, Email: zhangm@ecust.edu.cn.
Florencio Reginio, Email: fcreginio@up.edu.ph.
Data Availability Statement
The data that support the findings of this study are available from the corresponding authors upon reasonable request.
References
- 1. Barrett C. F., Corbett C. W., Thixton-Nolan H. L., and Biology C., A Lack of Population Structure Characterizes the Invasive Lonicera japonica in West Virginia and Across Eastern North America1, Journal of the Torrey Botanical Society. (2023) 150, no. 3, 455–466, 10.3159/TORREY-D-23-00007.1. [DOI] [Google Scholar]
- 2. Larson B. M. H., Catling P. M., and Waldron G. E., The Biology of Canadian Weeds. 135.Lonicera japonica Thunb, Canadian Journal of Plant Science. (2007) 87, no. 2, 423–438, 10.4141/p06-063, 2-s2.0-34347363035. [DOI] [Google Scholar]
- 3. Li R. J., Kuang X. P., Wang W. J., Wan C. P., and Li W. X., Comparison of Chemical Constitution and Bioactivity Among Different Parts of Lonicera japonica Thunb, Journal of the Science of Food and Agriculture. (2020) 100, no. 2, 614–622, 10.1002/jsfa.10056, 31597198. [DOI] [PubMed] [Google Scholar]
- 4. Li S. F., Guo X. M., Hao X. F., Feng S. H., Hu Y. J., Yang Y. Q., Wang H. F., and Yu Y. J., Untargeted Metabolomics Study of Lonicerae Japonicae Fios Processed With Different Drying Methods via Gc-Ms and Uhplc-Hrms in Combination With Chemometrics, Industrial Crops and Products. (2022) 186, 115179, 10.1016/j.indcrop.2022.115179. [DOI] [Google Scholar]
- 5. Wu Q. X., Zhao D., Leng Y., Chen C. H., Xiao K. Y., Wu Z. Q., and Chen F. M., Identification of the Hypoglycemic Active Components of Lonicera japonica Thunb. and Lonicera hypoglauca Miq. by UPLC-Q-TOF-MS, Molecules. (2024) 29, no. 20, 10.3390/molecules29204848, 39459215. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Chinese Pharmacopoeia Commission, Pharmacopoeia of the People′s Republic of China, China Medical Science Press: Beijing. (2020) 1. [Google Scholar]
- 7. Li J., Wang S.-P., Wang Y.-Q., Shi L., Zhang Z.-K., Dong F., Li H.-R., Zhang J.-Y., and Man Y.-Q., Comparative Metabolism Study on Chlorogenic Acid, Cryptochlorogenic Acid and Neochlorogenic Acid Using Uhplc-Q-Tof Ms Coupled With Network Pharmacology, Chinese Journal of Natural Medicines. (2021) 19, no. 3, 212–224, 10.1016/S1875-5364(21)60023-7, 33781455. [DOI] [PubMed] [Google Scholar]
- 8. Feng Y. H., Zhang G. D., Zhu P. C., Zhu W. H., Li Y. Z., and Fan X. W., Metabolite Profiles and Antibacterial and Antioxidant Activities of Leaf Extracts of Five Lonicera Species: A Comparative Study, Chemical and Biological Technologies in Agriculture. (2023) 10, no. 1, 10.1186/s40538-023-00460-1. [DOI] [Google Scholar]
- 9. Quintero Quiroz J., Naranjo Duran A. M., Silva Garcia M., Ciro Gomez G. L., and Rojas Camargo J. J., Ultrasound-Assisted Extraction of Bioactive Compounds From Annatto Seeds, Evaluation of Their Antimicrobial and Antioxidant Activity, and Identification of Main Compounds by LC/ESI-MS Analysis, International Journal of Food Science. (2019) 2019, no. 1, 3721828, 10.1155/2019/3721828, 2-s2.0-85070087623, 31392206. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Zhou L. K., Zhou Z., Jiang X. M., Zheng Y., Chen X., Fu Z., Xiao G., Zhang C. Y., Zhang L. K., and Yi Y., Absorbed Plant MIR2911 in Honeysuckle Decoction Inhibits SARS-CoV-2 Replication and Accelerates the Negative Conversion of Infected Patients, Cell Discovery. (2020) 6, no. 1, 10.1038/s41421-020-00197-3, 32802404. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Bacil G. P., Romualdo G. R., Rodrigues J., and Barbisan L. F., Indole-3-Carbinol and Chlorogenic Acid Combination Modulates Gut Microbiome and Attenuates Nonalcoholic Steatohepatitis in a Murine Model, Food Research International. (2023) 174, Pt 1, 113513, 10.1016/j.foodres.2023.113513, 37986509. [DOI] [PubMed] [Google Scholar]
- 12. Naylor L. H., Zimmermann D., Guitard-Uldry M., Poquet L., Leveques A., Eriksen B., Bel Rhlid R., Galaffu N., D′Urzo C., De Castro A., Van Schaick E., Green D. J., and Actis-Goretta L., Acute Dose-Response Effect of Coffee-Derived Chlorogenic Acids on the Human Vasculature in Healthy Volunteers: A Randomized Controlled Trial, American Journal of Clinical Nutrition. (2021) 113, no. 2, 370–379, 10.1093/ajcn/nqaa312, 33330899. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. He X. Y., Zheng S. J., Sheng Y., Miao T., Xu J., Xu W. T., Huang K. L., and Zhao C. H., Chlorogenic Acid Ameliorates Obesity by Preventing Energy Balance Shift in High-Fat Diet Induced Obese Mice, Journal of the Science of Food and Agriculture. (2021) 101, no. 2, 631–637, 10.1002/jsfa.10675, 32683698. [DOI] [PubMed] [Google Scholar]
- 14. Zhang Z., Shi C., and Wang Z., Therapeutic Effects and Molecular Mechanism of Chlorogenic Acid on Polycystic Ovarian Syndrome: Role of HIF-1alpha, Nutrients. (2023) 15, no. 13, 10.3390/nu15132833, 37447160. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Gupta A., Atanasov A. G., Li Y., Kumar N., and Bishayee A., Chlorogenic Acid for Cancer Prevention and Therapy: Current Status on Efficacy and Mechanisms of Action, Pharmacological Research. (2022) 186, 106505, 10.1016/j.phrs.2022.106505, 36243332. [DOI] [PubMed] [Google Scholar]
- 16. Rojas-Gonzalez A., Figueroa-Hernandez C. Y., Gonzalez-Rios O., Suarez-Quiroz M. L., Gonzalez-Amaro R. M., Hernandez-Estrada Z. J., and Rayas-Duarte P., Coffee Chlorogenic Acids Incorporation for Bioactivity Enhancement of Foods: A Review, Molecules. (2022) 27, no. 11, 10.3390/molecules27113400, 35684338. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Gao L., Li X., Meng S., Ma T., Wan L., and Xu S., Chlorogenic Acid Alleviates Aβ25-35-Induced Autophagy and Cognitive Impairment via the Mtor/Tfeb Signaling Pathway, Drug Design, Development and Therapy. (2020) 14, 1705–1716, 10.2147/DDDT.S235969, 32440096. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Freitas V. V., Borges L. L. R., Vidigal M. C. T. R., dos Santos M. H., and Stringheta P. C., Coffee: A Comprehensive Overview of Origin, Market, and the Quality Process, Trends in Food Science & Technology. (2024) 146, 104411, 10.1016/j.tifs.2024.104411. [DOI] [Google Scholar]
- 19. Wang H.-N., Shen Z., Liu Q., Hou X.-Y., Cao Y., Liu D.-H., Jiang H., and Du H.-Z., Isochlorogenic Acid (Icga): Natural Medicine With Potentials in Pharmaceutical Developments, Chinese Journal of Natural Medicines. (2020) 18, no. 11, 860–871, 10.1016/S1875-5364(20)60029-2, 33308609. [DOI] [PubMed] [Google Scholar]
- 20. Iwai K., Kishimoto N., Kakino Y., Mochida K., and Fujita T., In Vitro Antioxidative Effects and Tyrosinase Inhibitory Activities of Seven Hydroxycinnamoyl Derivatives in Green Coffee Beans, Journal of Agricultural and Food Chemistry. (2004) 52, no. 15, 4893–4898, 10.1021/jf040048m, 2-s2.0-3242797244, 15264931. [DOI] [PubMed] [Google Scholar]
- 21. Xu D., Wang Q., Zhang W., Hu B., Zhou L., Zeng X., and Sun Y., Inhibitory Activities of Caffeoylquinic Acid Derivatives From Ilex Kudingcha Cj Tseng on Α-Glucosidase From Saccharomyces cerevisiae , Journal of Agricultural and Food Chemistry. (2015) 63, no. 14, 3694–3703, 10.1021/acs.jafc.5b00420, 2-s2.0-84927941506. [DOI] [PubMed] [Google Scholar]
- 22. Li Q., Zhao B. J., Shi J., Chu J. B., Zhang X. Y., and Shi Q. Y., Efficient Preparation of Caffeoylquinic Acids From the Flowers of Artemisia Anomala by Supramolecular Solvent/Equilibrium Solution Extraction Followed by Re-Extraction, Separation and Purification Technology. (2021) 265, 118478, 10.1016/j.seppur.2021.118478. [DOI] [Google Scholar]
- 23. Liu Q. D., Yu H. H., Dong Y. Z., Quan W. J., Su Z. M., and Li L. Y., Quality Evaluation of Lonicerae Flos Produced in Southwest China Based on HPLC Analysis and Antioxidant Activity, Molecules. (2024) 29, no. 11, 10.3390/molecules29112560, 38893434. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Cao M. Y., Hu J. W., Gu Z., Xiong W., Wu L., Xu J. G., and Wu L. Y., Purification of Four Caffeoylquinic Acid Derivatives From the Flowers of Gynura procumbens by HSCCC, Journal of Chromatographic Science. (2021) 59, no. 10, 971–977, 10.1093/chromsci/bmab036, 33860306. [DOI] [PubMed] [Google Scholar]
- 25. Dawidowicz A. L. and Typek R., Thermal Stability of 5-O-Caffeoylquinic Acid in Aqueous Solutions at Different Heating Conditions, Journal of Agricultural and Food Chemistry. (2010) 58, no. 24, 12578–12584, 10.1021/jf103373t, 2-s2.0-78650395064, 21087030. [DOI] [PubMed] [Google Scholar]
- 26. Herawati D., Loisanjaya M. O., Kamal R. H., Adawiyah D. R., and Andarwulan N., Profile of Bioactive Compounds, Aromas, and Cup Quality of Excelsa Coffee (Coffea liberica var. dewevrei) Prepared From Diverse Postharvest Processes, International Journal of Food Science. (2022) 2022, 10.1155/2022/2365603, 2365603, 36032408. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Ayseli M. T., Kelebek H., and Selli S., Elucidation of Aroma-Active Compounds and Chlorogenic Acids of Turkish Coffee Brewed From Medium and Dark Roasted Coffea arabica Beans, Food Chemistry. (2021) 338, 127827, 10.1016/j.foodchem.2020.127821, 32798819. [DOI] [PubMed] [Google Scholar]
- 28. Gu L. F., Xie X. Q., Wang B., Jin Y. B., Wang L. J., Wang J., Yin G., Bi K. S., and Wang T. J., Discrimination of Lonicerae Japonicae Flos According to Species, Growth Mode, Processing Method, and Geographical Origin With Ultra-High Performance Liquid Chromatography Analysis and Chemical Pattern Recognition, Journal of Pharmaceutical and Biomedical Analysis. (2022) 219, 114924, 10.1016/j.jpba.2022.114924, 35816773. [DOI] [PubMed] [Google Scholar]
- 29. Zhang X. R., Yu X., Sun X. M., Meng X. B., Fan J., Zhang F., and Zhang Y. Q., Comparative Study on Chemical Constituents of Different Medicinal Parts of Lonicera japonica Thunb. Based on LC-MS Combined With Multivariate Statistical Analysis, Heliyon. (2024) 10, no. 12, 10.1016/j.heliyon.2024.e31722, e31722, 38975169. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Li W. J., Zhang L. Q., He P., Li H. Y., Pan X., Zhang W. L., Xiao M. F., and He F. Y., Traditional Uses, Botany, Phytochemistry, and Pharmacology of Lonicerae Japonicae Flos and Lonicerae Flos: A Systematic Comparative Review, Journal of Ethnopharmacology. (2024) 322, 117287, 10.1016/j.jep.2023.117278, 37972908. [DOI] [PubMed] [Google Scholar]
- 31. Zheng S. W., Liu S. T., Hou A. J., Wang S., Na Y. X., Hu J. H., Jiang H., and Yang L., Systematic Review of Lonicerae Japonicae Flos: A Significant Food and Traditional Chinese Medicine, Frontiers in Pharmacology. (2022) 13, 1013992, 10.3389/fphar.2022.1013992, 36339557. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Matei M. F., Jaiswal R., and Kuhnert N., Investigating the Chemical Changes of Chlorogenic Acids During Coffee Brewing: Conjugate Addition of Water to the Olefinic Moiety of Chlorogenic Acids and Their Quinides, Journal of Agricultural and Food Chemistry. (2012) 60, no. 49, 12105–12115, 10.1021/jf3028599, 2-s2.0-84870896711, 23106198. [DOI] [PubMed] [Google Scholar]
- 33. Lee J., Park G., and Chang Y. H., Nutraceuticals and Antioxidant Properties of Lonicera japonica Thunb. as Affected by Heating Time, International Journal of Food Properties. (2019) 22, no. 1, 630–645, 10.1080/10942912.2019.1599389, 2-s2.0-85069513517. [DOI] [Google Scholar]
- 34. Vereshchagina Y. V., Bulgakov V. P., Grigorchuk V. P., Rybin V. G., Veremeichik G. N., Tchernoded G. K., Gorpenchenko T. Y., Koren O. G., Phan N. H., Minh N. T., Chau L. T., and Zhuravlev Y. N., The rolC Gene Increases Caffeoylquinic Acid Production in Transformed Artichoke Cells, Applied Microbiology and Biotechnology. (2014) 98, no. 18, 7773–7780, 10.1007/s00253-014-5869-2, 2-s2.0-84906950822, 24938208. [DOI] [PubMed] [Google Scholar]
- 35. Deshpande S., Jaiswal R., Matei M. F., and Kuhnert N., Investigation of Acyl Migration in Mono- and Dicaffeoylquinic Acids Under Aqueous Basic, Aqueous Acidic, and Dry Roasting Conditions, Journal of Agricultural and Food Chemistry. (2014) 62, no. 37, 9160–9170, 10.1021/jf5017384, 2-s2.0-84924260600, 25116442. [DOI] [PubMed] [Google Scholar]
- 36. Moon J.-K. and Shibamoto T., Formation of Volatile Chemicals From Thermal Degradation of Less Volatile Coffee Components: Quinic Acid, Caffeic Acid, and Chlorogenic Acid, Journal of Agricultural and Food Chemistry. (2010) 58, no. 9, 5465–5470, 10.1021/jf1005148, 2-s2.0-77952122428, 20405916. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Supporting Information 1 The method validation of the high‐performance liquid chromatography (HPLC) adopted in this study, covering accuracy, stability, repeatability, and recovery.
Supporting Information 2 The mass spectrometry (MS) data of ion abundance for the six compounds.
Data Availability Statement
The data that support the findings of this study are available from the corresponding authors upon reasonable request.
