Skip to main content
Journal of Athletic Training logoLink to Journal of Athletic Training
. 1993 Fall;28(3):227–229.

The Reliability Of Three Isokinetic Knee-extension Angle-specific Torques

Brent L Arnold 1,2,3, David H Perrin 1,2,3, Evan V Hellwig 1,2,3
PMCID: PMC1317718  PMID: 16558236

Abstract

To determine the reliability of concentric quadriceps muscle torque at 30°, 60°, and 75° of knee extension, 25 female university students were studied. Each subject was tested on the Kin-Com isokinetic dynamometer on 2 separate days, 7 days apart. The dynamometer's speed was set at 60°ls. Intraclass correlation coefficients for 30°, 60°, and 75° were 0.84 (p<.01), 0.87 (p<.01), and 0.83(p<.01), respectively. The standard errors of the measure were 5.92 N·m, 7.65 N·m, and 7.35 N·m, respectively. Based on the instrumentation and protocol used in this study, we believe angle-specific torques have good reliability. Because of the error size, clinicians using similar methodology to determine angle-specific torques should be cautious when comparing differences between angle-specific torques of less than 12 to 16 N·m.

Full text

PDF
227

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Farrell M., Richards J. G. Analysis of the reliability and validity of the kinetic communicator exercise device. Med Sci Sports Exerc. 1986 Feb;18(1):44–49. [PubMed] [Google Scholar]
  2. Kannus P., Kaplan M. Angle-specific torques of thigh muscles: variability analysis in 200 healthy adults. Can J Sport Sci. 1991 Dec;16(4):264–270. [PubMed] [Google Scholar]
  3. Kannus P., Yasuda K. Value of isokinetic angle-specific torque measurements in normal and injured knees. Med Sci Sports Exerc. 1992 Mar;24(3):292–297. [PubMed] [Google Scholar]
  4. Kues J. M., Rothstein J. M., Lamb R. L. Obtaining reliable measurements of knee extensor torque produced during maximal voluntary contractions: an experimental investigation. Phys Ther. 1992 Jul;72(7):492–504. doi: 10.1093/ptj/72.7.492. [DOI] [PubMed] [Google Scholar]
  5. Snow C. J., Blacklin K. Reliability of knee flexor peak torque measurements from a standardized test protocol on a Kin/Com dynamometer. Arch Phys Med Rehabil. 1992 Jan;73(1):15–21. [PubMed] [Google Scholar]
  6. Tredinnick T. J., Duncan P. W. Reliability of measurements of concentric and eccentric isokinetic loading. Phys Ther. 1988 May;68(5):656–659. doi: 10.1093/ptj/68.5.656. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Athletic Training are provided here courtesy of National Athletic Trainers Association

RESOURCES